Intruder alarm system Operating Instructions
These operating instructions cover the following intruder system:
8SP 403 XR2+ G3 panel with built in keypad Unset system indications 8SP 404 XR2 G3 panel with built in keypad
Remote LED keypad
ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 Tamper Attack
For Clarity, the information given on setting the system, assume that all Programs use a timed or final door setting routine.
LED steady On indication LED flashing indication LED Off
o/p ARC Output to Alarm Receiving Centre
Unset system indications
An unset system will have both Day and Power indicators lit. This is a normal Day Power indication when the system is disarmed.
Internal sound
Sound description
NOTE: In general a flat beep is an indication of an incorrect key press. External devices Strobe Bell
Note: If the Power indicator goes off at any time then there is a mains supply failure at the security panel, consult your servicing organisation.
Set System indication
An active Set system will have only the Power Power indicator lit. This is an armed system indication.
issue 1 8/01
www.ukpanels.com
Operating instructions
Contents
Unset system indications Set System indication Access codes How to operate Personal Attack - - - How to unset system in alarm - - - - - Programs 1, 2 and 3 How to set the system (on program 1) - Push to Set Switch Keyswitch Set Faults during setting How to unset the system (turn off) - - How to set program1,2 or 3 - - - - - - How to Quick set - - - - - - - - - - - How to Omit zone(s) on setting system Fire Alarm How to set Chime Zones - - - - - - - Operators Program mode To exit operation at any time How to enter Operators program mode How to view the events log - - - - - - How to create/omit User 2 code - - - - How to change current user code - - - How to carry out Alarm and Walk testsServicing organisation details Quick Reference 8
Citadel XR2/XR2+ G3 Intruder system
How to unset system in alarm
Enter your code. Entering the code will turn the alarm off and the cause of the alarm will be displayed. After investigation press Reset to clear the indication.
n n n n
- - - -
FIRST ZONE IN ALARM OTHER ZONES IN ALARM
Investigate the Alarm
ALL ZONE
Strobe Off
Access codes
Note: If the alarm indication does not clear, then the system may need to be reset by the installation engineer, contact your installer for further information.
Programs 1, 2 and 3 Access codes
There are two User codes used in the system, both are 4 digit and can be set to any number from 0000 to 9999, signified by:
The user 1 and 2 codes have the same operation for testing, Setting and Unsetting, but user 1 code which is usually considered to be the Managers code has the authority to add, change or delete the user 2 code and Duress code.
The panel uses 3 Part Set routines known as Programs. In each Program the exit mode can be changed and the zone may be set up to have a different function. The examples below show how 3 typical Programs could be used in a house. Program 1 To arm all of the zones and become Set as the user leaves the property and closes the final door. Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds. Program 3 To protect the downstairs areas of the house at night and become Set silently. The above are purely examples. The installer has the ability at the programming stage to configure all the circuits to the customers exact requirements.
User 1 code 0123 factory set User 2 code not programmed.
How to operate Personal Attack
Personal Attack buttons on the keypad are used to activate the alarm, irrespective of whether the system is armed or not. Press Simultaneously: 9 4
How to set the system (on program 1)
The green Day indicator should be showing. Enter your code number and check Day that the system is clear (none of the n n n n zone indicators 10seconds are showing). The Exit beep insistent beeps sounder will now produce an exit Day beep tone and you should leave by o/p ARC the approved Set output route. The system will Set as the beep tone stops.
How to unset the system (turn off)
On entering the premises an entry beep tone come on. Enter your code, the green Day indicator is lit. The system is unset and disarmed.
Entry beep Day
Acknowledge Day
o/p ARC Unset output
Push to Set Switch
In some systems a Push to Set switch may be fitted outside the premises near to the main exit door. This should be used to complete the setting procedure once the building has been vacated. As the switch is operated, the exit beep tone will How to set program 1,2 or 3 stop and a chime tone will be produced to The green Day indicator should be showing. acknowledge setting. Day Enter your code number and the n n n n exit beep tone will start. Press Exit beep Keyswitch Set the Prog key and ZONE 1-3 Prog Exit beep the exit tone will Your system may have been fitted with a remote keyswitch. This can be used as an alternative to stop. Press 1, Or arming the system with a code and will set or 3 for the Program 1. required 10 seconds Exit beep insistent beeps program, the Where a keyswitch is used it may be necessary sounder will on occasions to allow it to catch up with the Day beep to system. For example if the alarm was set with a o/p ARC acknowledge the code, to Unset with the keyswitch, it would have Set output program number. to be momentarily turned to Set then returned to The exit beep tone will start and you should Unset. leave by the approved route. The system will Set as the beep tone stops.
Faults during setting
If the system is not clear when you try to Set it, the sounder will produce an open zone tone and the fault will be displayed. Either re enter your code to turn off and investigate or omit the faulty zone(s) from the system.
It is important that you follow the correct procedure when setting the system. After leaving the protected area it is absolutely essential that you wait until the exit tone stops, before assuming the system has set.
How to Quick set
During the exit period (on entering User code) Day the system may be Set Set the system or quickly by pressing Set. This removes the exit time Set a Program period.
5 seconds insistent beeps Day
How to set Chime Zones
Example: To set zone 3 and 4 to chime, Press:
o/p ARC Set output
If you omit zones and require Quick Set, you will need to press Set twice.
Timeout after 5 seconds if no selection is made
Day Chime
Deselect all zones (Factory default no chime) Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Appropriate Zone indicator is lit to show chime zone(s)
Zone n Chime selected Zone n Chime deselected
How to Omit zone(s) on setting system
Press number button to select / deselect Zone Chime
During the exit period after entering User code and selecting a Day program press Set the system or OMIT, the exit tone Set a Program and while the will stop and zones system is setting: that are about to be Omit armed will be ZONE(S) TO BE ARMED displayed. Key in Exit beep the zone number(s) to be omitted which Press the zone(s) n to be omitted will flash to confirm selection. Zone ZONE(S) TO BE OMITTED indicators which Set show steady are still about to be armed. 10 seconds Exit beep insistent beeps When the selection Day is complete press o/p ARC Set and the exit tone Set output will start. If a zone refuses to be omitted, it may be because the engineer has programmed the panel to prevent you from turning off the zone. If in doubt ask your installer for advice.
Leave chime mode
Fire Alarm
The fire zone will operate on detection of a fire, whether the system is Set or Unset, when configured as a 24 hour zone, and cause a distinctive internal sounder tone. The external sounders will pulse on and off at 2 second intervals and zone indicator will flash to attract attention.
Chime is a low security monitoring system for use when the system is Unset. When a zone that is set to chime is operated, the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show. The indicator may be cancelled by pressing Reset. Chime is particularly useful in a shop to warn of a customer presence or in a house to warn that a door or particular area has been accessed. Any zone may set to be on or off chime by pressing the CHIME key and then keying in the required zone number(s). Key 0 to cancel all zones from chime. After a few seconds the system will automatically return to the Day mode.
Operators Program mode
The information below shows the programmable options available and how to change them. Once the operator program mode has been accessed, each section may be changed in any order. As each operation is completed the system will automatically return to top level of program mode.
How to view the events log
The panel can hold up to 8 previous events which can be scrolled automatically or manually. The automatic scroll starts with the newest event ( number 8) to the oldest one ( number 1).
Example: To view up to 8 previous events and thereafter to stop the event scroll, Press: Prog Chime
Note: When programming the system should be in the Day mode, with the Day and Power indicators lit.
Enter Operators program mode
View the event log
Tamper
To exit operation at any time
On pressing the Reset key you will quit the current level of operation.
Automatic event scroll Starting from event 1 to 8 To manually scroll View event (oldest event)
Zone, PA and Tamper indicators will be lit to show zone in alarm. Flashing indicates the first zone in alarm. Day indicates status of panel at the time of alarm
Quit the current function Leave Engineering menu Down one menu level
View event 2 View event 3 View event 4 View event 5 View event 6 View event 7
How to enter Operators program mode
To enter the Operators program mode the system should be in Day Prog mode with the Day and ZONE 1 - 8 Power indicator lit. Momentarily On
8 View event 8 (Newest event) Chime Resume automatic scroll
Acknowledge
Stop event scroll / view Leave program mode
Day Acknowledge Tamper
How to create/omit User 2 code
User 1 code which is usually considered to be the Managers Example: To create user 2 code 4567, Press: code has the Prog authority to add, 7 change or delete Reset the user 2 code.
Enter Operators program mode Change / omit User code (By user 1 only)
Attack
How to create/change/omit the Duress code
The Duress code is used in a hold up situation where there is pressure to Set or Unset the system. Entry of the code will allow the system to work normally but also generate a silent PA type alarm by operating the PA communicator output. The duress code in not preprogrammed and can be created.
Example: To createduress 5555, Press:
ZONE 1-4
n New code
NOTE - The sounder will produce a flat beep if code is rejected.
Enter Operators program mode Change / Omit the Duress 9 Code (By user 1 only)
To omit the user 2 code
Rising beeps ZONE 1-4 Attack
Leave program mode
New duress code
How to change current user code
You can change the current user 1 or user 2 code Example: To change user 1 for security code from 0123 to 7777, Press: reason.
Change the code of Current user (either User 1 or User 2)
Current user new code
Rising beeps ZONE 1-4
NOTE - Factory default code for User 2 is not programmed
How to carry out Alarm and Walk tests
The alarm test function allows you to test the Strobe, Bell, Low and High volume sounders of the system. The walk test function allows each detector to be checked in order to verify that they are functioning correctly.
Example: To start bell test and thereafter to stop bell test. Prog 0 Reset Reset Enter Operators program mode
0 Alarm test
Press zero to turn off options 2,3,4 and 5 before selecting a new one
Strobe test
Strobe On Bell on
3 Bell test 6
Low volume sounder High volume sounder Walk test
internal low volume sound internal high volume sound Strobe
Strobe On
x1 for zone 1 x2 for zone 2 | x4 for zone 4 flat x1 for zone 5 flat x2 for zone 6 | flat x4 for zone 8 Rapid for PA Rapid for Tamper
Appropriate zone lights are lit(latched) Zones
Exit current level
Servicing organisation details
Servicing organisation name:
Bell Time: Bell delay Area protected Zone 1 Program 1 Program 2 Program 3
Telephone number:
Date of installation:
Zone 2 Zone 3
Account Number:
Zone 4 Zone 5
Installation Date:
Zone 6 Zone 7 Zone 8 T Timed (Entry/Exit Zone) TI Time Inhibited (Access zone to keypad) I Immediate (All zones armed to give full alarm)
Quick Reference
To Set a Program
Day Entry beep Day Day
To Set the system (Program 1)
n n n n n n n n
To Un-set the system To Quick Set the system Bell
To Reset Alarm state
To Omit zones on Setting system
Exit beep
Exit beep Acknowledge
FIRST ZONE IN ALARM
OTHER ZONES IN ALARM
Set the system or Set a Program
ZONE(S) TO BE ARMED
ZONE 1-3
Set the system or Set a Program and while the system is setting
10seconds insistent beeps
Or Day Day 10 seconds insistent beeps
Exit beep Day
5 seconds insistent beeps
nvestigate the Alarm
o/p ARC Set output o/p ARC Set output
Press the zone(s) to be omitted
ZONE(S) TO BE OMITTED
The panels conform to the requirements of the European EMC and Low Voltage directives, and carries the CE mark.
Operators program mode menu map
Chime Chime
Operators Progam Mode Prog
n n n 7
To exit Operators program mode
To set Chime zone
Alarm test Change / omit User code 2 (By user 1 only) Change the code of Current user (either User 1 or User 2) View the event log
n n n n n
10 seconds insistent beeps Day
Strobe test To omit the user 2 code
Automatic event scroll Starting from event 1 to 8 For manual scroll
Zone to chime
3 Bell test
View event 8 (Newest event)
Low volume sounder
Change / Omit 9 the Duress Code (By user 1 only)
Reset Reset
View event 1 (oldest event)
High volume sounder
Resume automatic scroll
Norma nd cat ons of an Unset system
Day Power
6 n n n
Walk test Press zero to turn off options 2,3,4 and 5 before selecting a new one
A arm nd cat ons
Stop event scroll / view
Quit the current function Leave program menu Down one menu level
Bell On
Strobe Tamper / Serv ce warn ng
Tags
Capture 4 32WP95E 42PD9700C VGN-NR21z S UE-55C8000 Classic-2002 Daikin RXS LN510 RX-DS30 Z-50P PC URU PSR-28 DC410 VR636 LV2787 HD ZD PC7280 A105-S4074 Samsung L768 P3650 57 12 AQ24FAN Ifinder H2O LH-CX245Y WD-1245FHB ECM21 IC-701PS W2243S-PF EW 300 B3210 7945G KLX140 Vivicam 4100 Roadster DVP3310 DES-7200-2 Soccer KD-G631 TC-32LX700 CT-M6R Server SPH-W3300 Qcard IC-T8e ICD-SX56 4262 C SF-10 IP8500 3 1 Ekhbrd014AAV1 RCD-S50 PRO 88 Dvdr70-051 NAS-D55HD D845gerg2 RSX-1067 EL-W516B Dimesions 11568 Laser PB8253 A632N 933HD 105S59-97 CB20F32T GST 85P Control RF20 SR 125 S-DV77ST - Pink Gmrs1582CH WS-55315 EOB53000X Rollei 35RF Mapamap 81883 B3191-5-M FE-50-FE-40-fe-30 RB-985 XM-7547 Manual CTK-700 CMT-EP30 CHA-1204 VN-90 Benq EF81 Installation Manual BD-HP21 DVP-NS328 Wide View LP250 SP-I600 MA400 Control YO-P20H 21FU1RL HD 372 Nokia 2100 ZI2500RV TU911 MC-7645B DCR-HC28E
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101