Reviews & Opinions
Independent and trusted. Read before buy Mitsubishi G-50A!

Mitsubishi G-50A


Bookmark
Mitsubishi G-50A

Bookmark and Share

 

Mitsubishi G-50AAbout Mitsubishi G-50A
Here you can find all about Mitsubishi G-50A like controller and other informations. For example: .

Mitsubishi G-50A manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Mitsubishi G-50A please write about it to help other people.
[ Report abuse or wrong photo | Share your Mitsubishi G-50A photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page 

Download (English)

 

Mitsubishi G-50A

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc1

IntesisBox Modbus Server - Mitsubishi Electric G50

datasheet v10 r12 eng

IntesisBox
Modbus Server - Mitsubishi Electric G50
Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel)

Master Modbus TCP

Modbus TCP Modbus RTU XML RS232/RS485 Ethernet

Master Modbus RTU

Mitsubishi Electric City Multi

LAN / WAN

LinkBoxMB Configuration Software
RS232 Only needed for configuration
This integration requires the Mitsubishi Electric City Multi AC system be equipped with the Mitsubishi Electric G-50A, GB-50A o AG-150A gateway. This gateway from Mitsubishi Electric offers the signals of the City Multi AC system through XML protocol. Every G50 (G-50A, GB-50A o AG-150A) allows access to the signals of up to 50 City Multi internal units and 50 groups, no matter the number of external units installed. In the G50, the group is the control unit, every group can have from 1 to 16 associated internal units. This integration supervises and control groups, not internal units, although if only one internal unit is associated to every group then you can supervise and control internal units individually. This G50 gateway is supplied by Mitsubishi Electric. Contact your nearest Mitsubishi Electric distributor for details.
IntesisBox can talk to up to 2 Mitsubishi Electric G50s using XML protocol, and offers the signals of all these City Multi groups through its Modbus slave interface, each signal in a predefined fixed Modbus address. The Modbus interface of IntesisBox can be freely configured as RTU RS232, RTU RS485 or TCP. The commissioning of IntesisBox is almost plug & play, only IP parameters of the box and of G50s have to be configured using LinkBoxMB, a friendly software configuration tool for WindowsTM supplied along with IntesisBox with no additional cost.
TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. The information in this document may change without preadvise.
1 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
Intesis Software S.L. - All rights reserved IntesisBox is a registered trademark of Intesis Software SL
IntesisBox Modbus Server - Mitsubishi Electric G50 IntesisBox capacity

Element Max. 2 Notes

Number of G50s
Number of independent G50 that can be defined into IntesisBox
Number of City Multi groups: (Number of G50s X 50)

Maximum number of groups

Number of variables per group

Modbus addresses

Number of variables per G50
Maximum number of variables
There are 2 different models of IntesisBox Modbus server - Mitsubishi Electric G50 with different capacity every one of them. The table above shows the capacity for the top model (with maximum capacity). The 2 different models allow integrating respectively: 1 or 2 G50s. And their order codes are: ME-AC-MBS-50. Model supporting up to 1 G50 and 50 City Multi groups. ME-AC-MBS-100. Model supporting up to 2 G50s and 100 City Multi groups.
2 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Sample applications
Integration of Mitsubishi Electric City Multi Air Conditioning systems equipped with the interface G50 into Modbus control systems. Master Modbus TCP
Control system with Modbus master interface: BMS. SCADA. PLC. DDC. Home Automation. AMX, Crestron
Typical Mitsubishi Electric Air Conditioning systems equipped with G50 interface: City Multi model G-50A (version of G50 with display and keypad), GB-50A (version of G50 with blind cover), and AG-150A (new version of G50 with touch-display) are all supported, no difference from IntesisBox's point of view. 50 City Multi indoor units or 50 groups per G50 Every group can have from 1 to 16 associated indoor units

MODBUS System supervising / controlling
Full supervision and control
System under supervision / control
3 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Typical applications
Integration of Mitsubishi Electric Air Conditioning into Modbus systems.
For this application, Mitsubishi Air Conditioning system must be equipped with G-50A, GB-50A or AG-150A Gateway. For more information about these devices contact Mitsubishi Electric.

Indoor units

Outdoor unit

Bus M-Net

G-50A, GB-50A or AG-150A. (with XML option) Ethernet (crossed cable)

Modbus network

Modbus Master TCP / RTU

ME-AC-MBS-50

4 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Modbus interface
General Max. Number of Up to two G50s can be supported. Mitsubishi Elec.G50s Virtual signals One communication error virtual signal per every G50 device defined. One communication error virtual signal per every group into the G50 device. One virtual signal per every group into the G50 device to enable/disable this group in the polling process. All these virtual signals can be read/written from Modbus. Modbus interface Device type Slave. Modbus modes TCP, RTU RS232 or RS485. supported Modbus TCP IP address. configuration Subnet mask. parameters Default gateway address. TCP port. Modbus RTU RS232/RS485. configuration Baud rate. parameters Parity. Slave number. Points No point configuration needs to be done, all the Mitsubishi Electric G50 Configuration signals are automatically associated to predefined fixed Modbus Addresses. Modbus function Read functions: codes supported 3- Read holding registers. 4- Read input registers. Write functions: 6- Write single register. 16- Write multiple registers.
If poll records are used to read/write multiple records, the range of addresses requested must contain valid addresses, if not the corresponding Modbus error code will be responded.

Modbus data coding

All the point's values are coded in 2 bytes registers (even if their possible values are 0 and 1) and expressed in MSB.LSB.
5 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
Extract of the predefined Modbus address table

Modbus Address 118 G1 1

Property 0 Error Com. GDrive 2 Mode 3 SetTemp 4 AirDirection 5 FanSpeed 6 RemoCon 7 DriveItem 8 ModeItem 9 SetTempItem 10 FilterItem 11 Ventilation 12 FilterSign 13 ErrorSign 14 InletTemp 15 FilterSignReset 16 ErrorSignReset 17 Error Com. Group 18 Polling Active

Modbus Address 5118

Modbus G50 Group Property Address Drive 50
Modbus G50 Group Property Address Drive Mode 3 SetTemp 4 AirDirection 5 FanSpeed 6 RemoCon 7 DriveItem 8 ModeItem 9 SetTempItem 10 FilterItem 11 Ventilation 12 FilterSign 13 ErrorSign 14 InletTemp 15 FilterSignReset 16 ErrorSignReset 17 Error Com. Group 18 Polling Active
2 Mode 3 SetTemp 4 AirDirection 5 FanSpeed 6 RemoCon 7 DriveItem 8 ModeItem 9 SetTempItem 10 FilterItem 11 Ventilation 12 FilterSign 13 ErrorSign 14 InletTemp 15 FilterSignReset 16 ErrorSignReset 17 Error Com. Group 18 Polling Active
There are also a series of signals that indicate an Alarm Code in any of the devices present in the M-Net Mitsubishi network. To obtain the Modbus address, you must apply following formula: ADRESS MODBUS = (20000+ (Numb.G50x1000)) + M-Net Add
where M-Net Add is 0 for the G50 device, 1 to 50 for Indoor Units, 51 to 100 for Outdoor Unit, 101 to 200 for Remote Controllers and 200 to 250 for System Controllers.
For more information contact Mitsubishi Electric
6 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Mitsubishi Electric G50 interface
Mitsubishi Electric G50 interface Device type Configuration Parameters
Client. Polling interval (1.600 seconds). Per every G50 defined: Descriptive name. IP address. TCP port.
7 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
Signals available per every Mitsubishi Electric City Multi AC indoor unit or group of indoor units
Property Drive Mode Description / Status Start/Stop Read/Write: ON, OFF AC Mode Read/Write: COOL, DRY, FUN, HEAT, AUTO, HEAT RECOVERY, LC_AUTO, BYPASS Read: AUTO HEAT, AUTO COOL Temperature Set Point (only integer numbers allowed) Read/Write: For COOL or DRY mode:19.30 C, for HEAT mode: 17.28 C, for AUTO mode:19.28 C) Air output direction Read/Write: HORIZONTAL, MID1, MID2, VERTICAL, SWING AC fan speed or LOSSNAY Read/Write: HIGH, MIDH, MIDL, LOW Prohibition for General control from the local panel Read/Write: PROHIBIT, PERMIT Prohibition for ON/OFF control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Mode control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Set Point control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Filter Reset control from the local panel Read/Write: CHK_ON, CHK_OFF Operational status for LOSSNAY or OA Read/Write: HIGH, LOW, OFF Status for Filter Dirty Read: ON, OFF Write: RESET Error status Read: ON, OFF Write: RESET Ambient Temperature Read: 0.0 to 99.9 Communication error with G50 Virtual signal generated by IntesisBox to indicate the status of the communication with the G50. Group communication error Virtual signal generated by IntesisBox to indicate that the group is not configured into the G50. Polling active Virtual signal to indicate or set if the Group is active or not active during the polling process. Group Alarm Code This signal provides a value. Each value has an associated alarm that has occurred in the group (0 means no alarm).

SetTemp

AirDirection FanSpeed RemoCon DriveItem ModeItem SetTempItem FilterItem Ventilation FilterSign

ErrorSign

InletTemp G50 Communication Error Group Communication Error Polling Active

Alarm Code

8 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Configuration tool

LinkBoxMB

Visual engineering tool, easy of use, for gateways configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge. Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateways parameters and signals. Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the gateways parameters and signals while in off-line (not connected to the gateway). Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway). Allows configuring all the external protocols available for IntesisBox Modbus Server series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Modbus Server series. Multi-project tool allowing having in the engineers PC the configuration for all the sites with different IntesisBox Modbus Server series gateways. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request).
9 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Mechanical & Electrical characteristics

Envelope Color Power

Mounting options Modbus RTU ports Modbus TCP & Mitsubishi Elec.G50 port LED indicators

Plastic type PC (UL 94 V-0). Size: 107mm x 105mm x 58mm. Grey. RAL 7035. 9 to 30VDC +/-10% 1.4W. 24VAC +/-10% 1.4VA. Power connector is a 2 pole plug-in screw terminal bloc. Wall DIN rail EN60715 TH35. 1 x Serial RS232 (DB9 male DTE). 1 x Serial RS485 (Plug-in screw terminal block 2 poles). 1 x Ethernet 10BT RJ45 connector.
Console port Configuration Firmware Operational temperature range Operational humidity range Protection RoHS conformity Certifications
1 x Power. 2 x Ethernet port link and activity (LNK, ACT). 2 x Modbus RTU port activity (Tx, Rx). RS232. DB9 female connector (DCE). 1 Via console port. Allows upgrades via console port. 0 to +70C C 5% to 95%, non condensing IP20 (IEC60529). Compliant with RoHS directive (2002/95/CE). CE
Along with the device it is also supplied a standard DB9 male - DB9 female 1.8 m. cable for configuring and monitoring the device using a PC via serial COM port. The configuration software, compatible with MS Windows operating systems, is also supplied.
10 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134
IntesisBox Modbus Server - Mitsubishi Electric G50 Dimensions

Power + Ethernet port

Modbus RTU RS232/mm Console port

107 mm

105 mm
Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections:

100 mm

130 mm 115 mm
11 / 11 URL email tel http://www.intesis.com info@intesis.com +34 938047134

 

Tags

PS-7900 H KH 2158 Corsa FAX L280 N8 N12 A7N266C DXZ648RMP Gpsmap 178C AVR 135 F8010S LP340B MS-7528 AW2147S DMC-LZ2 Muratec M800 Lucas MAX CP-S860 Temperature 16 PS-424X CQ-C7301 5500Z Resin 2123 RZ-26LZ55 32LH20 930CM F100I W450 SE Acer G24 XV-Z15000 DVP-K370 CX-77biii RCM 169 YP-U1 SC-AK280 SGH-X150 Ultigrill AY89 M-BD1 KDL-46EX505 Minolta 7130 42LG70-UA Zoom 115 Samsung E908 42PB120S5 High T U5-632H 9 9DM ECS5000 KX-TCD706SLS Guitar 670 L PRO 10 HDR-XR200VE UF-8100 SM-348B Rodziny H1 OPR 3201 Pocket 9 TDI CCD-TRV85 6000I M35-S456 J-9940W AW120T HDR-TG5VE MA-1350-1 IC-PW1euro C525BEE 14 0 20SH1E CE1000-TS Neximage DLA-SX21su-dla-sx21 XR-C503 PMA-1315R VP-W70 SGH-T619 VN-2000 SD-2060 NN-A883wbbpq KD-R401E 40C7000 ICD-50 Diagram EX-S880 Freestar-2006 QRX-5500 DV LCD71VM Durst M305 Siemens AX75 Ultra MD-MS722H RH7521W Zanussi T633 AVX-7300 254 SXX KX-TG4500B Reflector HCD-101 DR4800

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101