Reviews & Opinions
Independent and trusted. Read before buy Siemens Nitro CIC!

Siemens Nitro CIC


Bookmark
Siemens Nitro CIC

Bookmark and Share

 

Siemens Nitro CICAbout Siemens Nitro CIC
Here you can find all about Siemens Nitro CIC like hearing aid and other informations. For example: .

Siemens Nitro CIC manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Siemens Nitro CIC please write about it to help other people.
[ Report abuse or wrong photo | Share your Siemens Nitro CIC photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Siemens Nitro CIC, size: 465 KB

 

Siemens Nitro CIC

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

NITRO and NITRO 16 CIC

Instruction Manual for NITRO and NITRO 16 Completely-in-the-Canal and Mini Canal Hearing Instruments
Siemens Hearing Instruments
Your NITRO /NITRO 16 CIC or MC hearing instruments
Your hearing instrument is custom made to fit to the contours of your ear canal. Each instrument can be identified by a serial number found on the outside of the instrument. If the number appears in red, this hearing instrument is for the right ear. If the number appears in blue, this hearing instrument is for the left ear.

NITRO/NITRO 16 CIC/MC

3456R 08N012

6a 7a 4a 10a 9a

08N0123456R

8a 1a 2a 3a 5a

Fig. 1: Right NITRO CIC (Completely-in-the-Canal) hearing instrument
1a 08 Year manufactured 2a N Facility code where instrument was manufactured 3a Serial number 4a NIT or NIT 16model type 5a R or LRight or Left ear instrument 6a Indicator dotThis dot indicates which ear the instrument fits. A blue dot indicates the left ear, and a red dot indicates the right ear. 7a Receiver 8a Removal strand 9a Battery compartment door 10a Microphone
2 Siemens Hearing Instruments
Volume control wheel Battery compartment door 5b

NIT 08N123456R

Microphone
Fig. 2: Right NITRO MC (Mini Canal) hearing instrument
1b 08 Year manufactured 2b N Facility code where instrument was manufactured 3b Serial number 4b R or L Right or Left ear instrument 5b NIT or NIT 16 model type Because your hearing instrument was custom made, its appearance may vary from the one that is pictured.
The battery compartment holds the battery that powers the instrument. Position of the battery door may change due to the shape of your ear canal. The vent hole, which can appear in various locations, provides comfort and pressure release. Digital Technology Inside your hearing instrument, the microphone, analog-to-digital converter, digital signal processor, receiver and other specialized components process sound that is directed to the eardrum and auditory system. The microphone picks up sound waves from the air and converts them to electrical signals.
The analog-to-digital converter encodes the electrical signals into a format that is usable by the digital signal processor. The digital signal processor has been programmed by your Audiologist or Hearing Care Provider to execute the required digital signal processing for your particular hearing loss. The receiver converts the digitally processed signal directly back into sound waves.
Using your hearing instrument
Battery The chart below provides the battery size generally used in your hearing instrument. However, since your hearing instrument is a custom product, its strongly recommended that you check with your Audiologist or Hearing Care Provider regarding the correct battery for your model. Model NITRO CIC and NITRO 16 CIC NITRO MC and NITRO 16 MC Battery size 10A 10A
Before using your hearing instrument, place the battery into the battery compartment door. Using the fingernail of either your thumb or index finger of your other hand, pull the tab on the battery compartment door outward until the compartment door swings open all the way (Fig. 3).

"+" Sign

Battery

Battery compartment door

Fig. 3: Right Nitro CIC hearing instrument
Place the battery (see "Battery" section or consult your Audiologist or Hearing Care Provider) into the battery compartment door, observing the correct polarity. The "+" sign on the battery must match the "+" sign stamped on the top of the battery compartment door (Fig. 4).
Fig. 4: Right Nitro CIC hearing instrument

NITRO/NITRO 16 CIC/MC 7

Gently close the battery compartment door. Avoid forcing the battery door shut. If it does not close easily, check to see if the battery was inserted properly. Once the battery is in its proper position, your instrument is ready to operate. Power-on delay feature Your hearing instrument may be equipped with an advanced power-on delay feature. This feature delays sound from entering your hearing instrument when it is first turned on, so that you may insert it into your ear without experiencing unpleasant feedback (whistling). To turn your instrument on, insert the battery and close the door. To turn off your instrument, open the battery door fully so that no contact remains.
Make it a habit to remove the battery every time you take off your hearing instrument.
Removal strand Your hearing instrument may have a clear nylon strand that serves as a removal cord. Never remove or cut this strand. If the strand pulls off, breaks or is damaged in any way, contact your Audiologist or Hearing Care Provider immediately. Inserting and removing your NITRO CIC hearing instrument Hold the hearing instrument between your thumb and index finger. With the face of the hearing instrument toward the outside, place the hearing instrument into your ear canal. Gently work it into its proper position by slightly twisting until it is firmly seated. Lightly press inward for a secure and comfortable fit (Fig. 5). If you have difficulty inserting the hearing instrument, try pulling the ear up and back for an easier insertion. Your instrument should sit deep in your ear canal, but do not force it deeper than it will comfortably fit.

Fig. 5: Proper location of the Nitro CIC hearing instrument
The nylon strand has been provided to allow removal of the hearing instrument. Firmly grasp its bead and slowly, gently pull the hearing instrument out of your ear. It often helps to push lightly on the back of your ear to loosen the instrument. Using the removal strand, the hearing instrument should pull out easily. If you experience difficulty removing the instrument and it remains lodged in your ear, contact your Audiologist or Hearing Care Provider immediately.
10 Siemens Hearing Instruments
Inserting and removing your NITRO Mini-Canal hearing instrument Hold the instrument between the thumb and index finger. With the face of the instrument toward the outside, place the canal portion into your ear. Gently work the instrument into its proper position by slightly twisting it until it is firmly seated. Lightly press inward for a secure and comfortable fit (Fig. 6).
Fig. 6: Inserting the Mini-Canal hearing instrument
When removing the instrument, push lightly on the back of the ear to help loosen it. Then, using your index finger, gently pull the hearing instrument from your ear.
Do not insert any item into your ear to remove the hearing instrument. Do not pull on the battery compartment door to remove the hearing instrument as this could cause damage to the instrument.
Using the memory button Your NITRO or NITRO 16 hearing instrument may have a memory button to access up to 3 memories, also called hearing programs. Each memory is different and designed to help you hear better in certain situations. Your Audiologist or Hearing Care Provider will program the settings in the different memories for your particular needs. When initially turned on (after the battery compartment door is closed) the microphone is ON and ready for general use and the default setting is Memory 1. Your Audiologist or Hearing Care Provider will provide you with the number of memories most appropriate for your needs. Each time you press the memory button, your NITRO CIC hearing instrument changes
to another memory. The memory change may be confirmed by alerting tones or beeps which correlate to the memory you are in. That means if you select memory "3" then the hearing instrument beeps 3 times. Your Audiologist or Hearing Care Provider has programmed your instrument as follows:

Memory number 3 Listening environment _________________________________ _________________________________ _________________________________
If no memory button is provided, your Audiologist or Hearing Care Provider will program the instrument to automatically adjust to a wide variety of listening environments without any effort on your part.
Low Battery Indicator Your hearing instrument may be programmed to inform you when the battery should be replaced for best performance. If this feature is activated in your hearing instruments, you may hear two long, low pitched beeps and/or experience low amplification power or volume. Change the battery immediately when either of these occur. WARNING: Choking hazard posed by small parts. Keep hearing instruments, batteries and accessories out of childrens reach. If swallowed consult a physician or a hospital immediately. If infants, small children or mentally disabled persons need to wear hearing instruments, ensure adequate supervision. Battery tips CAUTION! Batteries can be harmful if swallowed. If a battery is accidentally swallowed, seek medical attention immediately,
or call The National Button Battery Hotline collect at (202) 625-3333. Always use the battery size recommended on your warranty card or by your Audiologist or Hearing Care Provider for your model for best performance. Remove the battery from your instrument when not in use. This prevents possible damage from expansion or leakage of the battery, if the instrument is not fully turned off. Always carry spare batteries in the event that your current battery goes dead. Place each spare battery in an individual, non-metallic container to prevent contact with other batteries or metal objects, such as keys or coins. Follow your local recycling rules for battery disposal.
Note: Do not throw used batteries into household trash. Return them to your Audiologist or Hearing Care Provider for environmentally correct disposal.
WARNING: Risk in explosive environments, e.g. mining areas! Dont use your hearing instruments (and remote control) in areas where there is a danger of explosions. Health considerations If soreness or skin irritation develops in the ear, discontinue wearing your hearing instrument, and bring the instrument to your Audiologist or Hearing Care Provider. Minor fit adjustments and polishing can often correct this condition. If soreness persists discontinue wearing the hearing instrument and see your physician. If excessive ear wax accumulates when wearing your hearing instrument, consult your Audiologist or Hearing Care Provider. Using the telephone You may use the telephone in a natural manner. If you get a whistling sound (feedback), tilt the phone receiver away from your ear and/or reduce the volume until the whistling stops. By trying various positions of the telephone receiver, you will discover what works best for you.

16 Siemens Hearing Instruments
Your Audiologist or Hearing Care Provider:
Siemens Hearing Instruments, Inc.
P.O. Box 1397 Piscataway, NJ 08855-1397 www.usa.siemens.com/hearing
Information in this manual subject to change without notice. Copyright 2008 Siemens Hearing Instruments, Inc. All Rights Reserved
10294607 10/08 5.1 22C108 5K SHI/09995-8

doc1

NITRO CIC and NITRO 16 CIC

Power takes many forms.

Break the Sound Barrier.

www.siemens.ca/hearing

Shattering prior limitations of CICs.
If you have severe hearing loss, you may have been told that Completely-in-the-Canal (CIC) hearing instruments arent for you. Simply put, CICs have never been powerful enough to meet the needs of people with severe hearing loss. Until now. Introducing NITRO CIC and NITRO 16 CIC hearing instruments that shatter the prior limitations of CICs. With NITRO CIC and NITRO 16 CIC, even people with severe hearing loss may benefit from Completely-in-the-Canal hearing instruments.
The CIC youve been waiting for.
Hearing technology has finally caught up to your needs. NITRO CIC and NITRO 16 CIC offer the power of Behind-the-Ear hearing instruments, but in a much smaller package that fits entirely in the ear canal. They also offer improved feedback cancellation technology, which reduces or eliminates the unwanted feedback noise that can be associated with CICs. Thanks to NITRO CIC and NITRO 16 CIC, more people can enjoy the desirable cosmetic advantages of CICs. In fact, when theyre in your ear, NITRO CIC and NITRO 16 CIC are practically invisible. So people will notice youre hearing better and nothing else.
NITROTM CIC and NITROTM 16 CIC. Power takes many forms.
While NITRO CIC and NITRO 16 CIC pack up to 70 decibels of gain into a tiny package (significantly more than other CIC products), they have more to offer than just out-of-this-world power. NITRO CIC and NITRO 16 CIC also have a variety of features that will enhance your hearing experience. Feedback cancellation. Provides a more pleasant listening environment by eliminating or reducing feedback sounds (whistling). Data logging. Records important data that your Hearing Care Professional can use to better fine-tune your instrument. Stationary noise reduction. Reduces steady-state noises such as cars and fans, and makes listening more effortless. Speech enhancement. Reduces noise in the presence of speech. Makes speech easier to hear in noisy situations. Microphone noise reduction. Reduces low-level background noise in quiet environments. C-Guard wax protection system. Protects the receiver, and enhances durability and reliability. Optional push button. Accesses multiple programs for optimal hearing in a variety of situations.
NITRO 16 CIC also features:
SoundSmoothing. Automatically distinguishes and supresses annoying, sudden or impulsive sounds. 16 Frequency shaping channels. Enhanced precision when processing sounds.

The power to choose.

If CIC hearing instruments were not an option for you in the past, NITRO CIC or NITRO 16 CIC could be the answer. Talk to your Hearing Care Professional to learn more about the power of NITRO CIC and NITRO 16 CIC.
Hearing instruments may help people hear better, but no hearing instrument can solve every problem or restore hearing to normal. Information in this brochure is subject to change without notice. Copyright 2008 Siemens Hearing Instruments, Inc. All rights reserved. Siemens Hearing Instruments A Division of Siemens Canada Limited 320 Pinebush Road Cambridge, Ontario N1T 1Z6 www.siemens.ca/hearing

NITROTM CIC and NITROTM 16 CICs are available at:
304886C SHI/001832 01/08 V1.0 (TCD)

 

Tags

CT-M601R KX-T7533 -III 150 1000DS Ngage QD HI535 30132 SBO-WR37TB CQ-C1312NW Ericsson Aino Sdrh85 E 100 Sedan NV-VX22EG Hdcsd700 CD 2006 NW-E005 47LB9DF EX-P700 Rosetta AD SPR-4416 Yamaha B-2X BC 2255 IC-M45euro GPS-009 LMV1680ST Lide 90 Piranha 2 TX-SA806 Plantronics K100 Zoom R16 Model 2770 MH035fnea CCD-TRV57 AL1711 Nitrox MC1761E-M DVP5996K 6 XL SRS-DF30 TX-32LX60P TH-42PZ80A TDM-IP1 Express Mercedes 230E AAM6000UG WD-80180NU ZBM762W B-SP2D Roadmate 1424 SPA-2002 79-290 14 0 M2N68 CT-5071 Contax RTS3 Legend Xsat 410S RL41sbsw 7510A Yamaha A15 Schuko Iphone OS Truck PT-L785U 112 Plus BH-900 V-CP243NDN 8I 16V Lifestyle V20 BDV-E770W AW1046F Legria HF20 Lexmark X651 Transit RKI8400 Musicpal PM-30 RP155 FL411CN 1 DVD ICD-SX77 SD-255 KT100 WF8590NFW F1407 Fujifilm F10 Canon I950 ZS-S4ipblack Photosmart 1100 DVI-9990 Digimax A7 3070C It14N ST-E2 XS-L151p5S PSR-350 CP-80 F100FD SRU1010-10

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101