Reviews & Opinions
Independent and trusted. Read before buy Daikin Altherma!

Daikin Altherma


Bookmark
Daikin Altherma

Bookmark and Share

 

About Daikin Altherma
Here you can find all about Daikin Altherma like heat pump and other informations. For example: installation manual, price list, price, ht, system, monobloc, us, cost, usa.

Daikin Altherma manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Daikin Altherma please write about it to help other people.
[ Report abuse or wrong photo | Share your Daikin Altherma photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Daikin Altherma, size: 1.1 MB

 

Daikin Altherma

 

 

Video review

Altherma Air Source Heat pumps from SpaceAir

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

energy costs? The heat pump is currently the most efficient indoor comfort system on the market: a cutting-edge technology with clear benefits for you and the environment.
DAikin HeAt pump experience Daikin has more than 50 years of experience with heat pumps, and supplies more than one million of them to homes, shops and offices each year. This success is not just a quirk of fate: Daikin has always been at the cutting edge of technology and its goal is to provide you with turn-key comfort. Only a market leader can guarantee you this level of service and quality control! HigH efficiency meAns low energy costs Heating system efficiency is measured using the Coefficient of Performance (COP), which is the ratio of heat produced to energy consumed.

3 in 1 GUARANTEE

A GOOD DESIGN IN JUST 3 STEPS

STEP 1 STEP 2 STEP 3

Calculation of heat losses (Transmission and ventilation losses) Selection of Daikin Altherma based on heat loss calculation and preferably for a low water temperature application (104F - 95F) Tip: Use the available Daikin selection and software tools (see page 27) Selection of heating terminal unit solution, after choosing Daikin Altherma unit, with a T = 5 Tip: Remember to consider the pump characteristic of the provided circulator!
daikin ALTHERMA System configurationS

Mono-valent

>> >> >>

Mono-energetic

Uses heat pump energy only Ideal for new construction 100% heat pump coverage: selection of bigger capacity and higher investment cost heat pump
Heat pump Hydro box Radiators/
Uses heat pump energy with backup electric heater Ideal for new construction Best balance between investment cost and running cost, results in lowest lifecycle cost

Back up heater*

floor heating

Heat pump

Hydro box

Radiators/

Back up heater is only used below the equilibrium point
Mono-valent (heat pump only)
Heat pump capacity Heating requirement
Mono-energetic (heat pump + heater)

Coldest day of the year

Heating requirement
Covered by heat pump Spare heat pump capacity

Equilibrium point

Heat pump capacity Covered by heat pump Covered by back up heater Spare heat pump capacity
*Back up heater is mounted inside the hydrobox

BI-valent

U ses heat pump energy with auxiliary boiler I deal for refurbishment/upgrade

Boiler

space heating with an auxiliary boiler
Boiler is only used below the equilibrium point
1. Space heating application by either the Daikin Altherma Hydrobox or by an auxiliary boiler connected in the system. 2. An auxiliary contact decides whether the Hydrobox or the boiler will operate. 3. The auxiliary contact can be an outdoor temperature thermostat, an electricity tariff contact, a manually operated contact, etc. 4. Domestic hot water in such an application is always produced by the system tank connected to the Hydrobox, including when the boiler is in operation for space heating. 5

Bi-valent (heat pump + boiler)
Heat pump capacity Covered by heat pump Covered by auxiliary boiler Spare heat pump capacity

2.THE BASICS

Daikin offers you the choice between a Daikin Altherma system with an outdoor unit and indoor unit, or a Daikin Altherma Monobloc System, in which the hydrobox components are located within the outdoor unit.
Daikin Altherma split type
Application Heating and (optional) cooling (+ domestic hot water)
outdoor & indoor unit
Heat pump type R-410A refrigerant piping H2O piping Installers advantages
Outdoor (compressor) unit + Indoor (hydronic parts) unit Between outdoor unit and indoor unit Between indoor unit and indoor heating appliances No extra insulation of H2O piping required to protect from freezing up
The Split system can be combined with - Under floor heating - Fan coil units - Low temperature radiators to provide your customers the comfort they require. In addition, the Split system can be connected to A domestic hot water tank to supply your customers hot water needs Solar collectors, with optional solar kit, to compliment the production of hot water A room thermostat, to regulate the ideal temperature easily, quickly and conveniently. 6

the basics

Daikin Altherma monobloc

monobloc outdoor unit

Outdoor unit only (compressor and hydronic parts combined) Inside outdoor unit Between outdoor unit and heating terminal units Only H2O piping needed to install the system
The monobloc system can be combined with - Under floor heating - Fan coil units - Low temperature radiators to provide your customer the comfort they require. In addition, the monobloc system can be connected to A domestic hot water tank to supply your customers hot water needs Solar collectors, with optional solar kit, to compliment the production of hot water A room thermostat, to regulate the ideal temperature easily, quickly and conveniently. 7

Air-to-water HEAT PUMP

THE BASICS
The system consists of 5 components which together to provide the ideal comfort and water temperature. 1B/ hydrobox : the heart of the Daikin Altherma system

With the wired room thermostat, the ideal temperature can be easily, quickly and conveniently regulated.

3/ Monobloc outdoor unit

3.TECHNICALLY
1 - daikin ALTHERMA Split type Air-to-water HEAT PUMP

THE OUTDOOR UNIT

Compact, weather-resistant and easy to install Contains an inverter controlled compressor for energy efficiency and precise temperature regulation Heat pump operation range: heating and domestic hot water to -4F outside temperature
HEAT EXCHANGER ANTI-CORROSION TREATMENT
As standard, the heat exchanger in the outdoor unit is provided with an anti-corrosion treatment. This treatment guarantees and noticeably increases the resistance against acid rain and salt corrosion.
Typical Daikin heat exchanger Hydrophilic layer Aluminium Corrosion-resistant acrylate resin
SUPER PERFORMANCE THANKS TO THE INVERTER PRINCIPLe
The coefficient of performance (COP) of the Daikin Altherma heat pump is also largely attributable to the Daikin inverter principle. An integrated frequencyconverter adjusts the rotational speed of the compressor to suit the heating demand. Therefore, the system seldom operates at full capacity and your customer only pays for the energy which they actually need.

Heating operation:

Temperature / Power input Temperature remains stable System without Inverter System with Inverter Time

Slow start Set temp.

HIGH EFFICIENCY COMPRESSORS:
The scroll-compressors provided are designed as a compact, robust, low-noise device to guarantee optimal operational reliability (no valves and built-in swing-link coupling) and efficiency (through a low initial flow and a constant compression ratio).

TECHNICALLY

hydrobox
Available in two versions: EKHBH for heating only, EKHBX for heating and cooling Built-in electric back-up heater for additional heating during extremely cold outdoor temperatures or as back-up in case of problems with the outdoor unit 2 shut-off valves to assemble the water outlet and inlet Compact and easy to install: all components are pre-assembled, all parts are easy to reach for maintenance. Wall-mounting is comparable to a traditional gas heater.
Heat exchanger Expansion tank (2.64 gal.) Circulator Tank with back-up heating Air purge valve Refrigerant fluid connection Refrigerant gas connection Water inlet connection Water outlet connection

3. 1. 2. 4. 12. 5.

1. 2. 3. 4. 5. 6. 7. 8. 9.
10. Pressure gauge (water circuit) 11. Water filter 12. Pressure relief valve 13. User interface 14. Switch box 15. Flow switch
15. 13. 10. 11. 7. 9. 8. 6.
EXTRA POSSIBILITIES THANKS TO THE Indoor unit
Heating and Cooling If you choose Daikin Altherma with an indoor unit EKHBX, it can not only heat the house, but also cool it. The heat pump is then equipped with a reversible 4-way valve, whereby the refrigeration cycle is reversed and heat is removed from the rooms. The indoor unit can cool rooms via under floor cooling or fan coil units.

3 - THE domestic HOT WATER TANK
Available in 2 capacities: 50 and 80 gallons for floor mounted installation.
Stainless steel design. 1 37/64 cfc-free insulation material (polyurethane). Contains 2 heating elements: a heat exchanger at the bottom where the hot water from the hydrobox circulates and an extra 3 kW electric heater at the top. A thermistor in the hot water tank controls a 3-way valve and/or booster heater via the hydrobox.
Field supply Hot water connection Pressure relief valve connection Pressure relief valve (field supply) Electrical box Electrical box lid Recirculation hole Thermistor socket Flow inlet connection
10. Heat exchanger coil 11. Return outlet connection 12. Cold water inlet 13. Threaded thermistor hole for use
with solar kit option. (Refer to the Installation manual EKSOLHWBAVJU).
MULTIFUNCTIONAL HOT WATER TANK
>> Stainless steel Daikin offers a tank made of stainless steel equipped with a sacrificial rod to protect the tank against corrosion. >> Anti-bacteria function To prevent the development of bacteria, the hot water tank is equipped with an anti-bacteria function. You can set up the program so the water is heated to a specific temperature (standard setting = 158F) at a set time on one or more days of the week. >> Flexible control It is possible to set priority setting for the production of domestic hot water. In this way the customer has domestic hot water available at any time of the day. The heating of the domestic hot water can also be set up according to the night tarif. Another opportunity for rational energy consumption.
>> Regulating switch-on and shut-off temperatures You personally set the minimum and maximum temperature when the water in the tank must be heated by the heat pump for the customer. >> Delaying booster heater switch-off To prevent the booster heater from switching on and off too often, you can allow the system to switch off as soon as the temperature reaches a maximum of 39F higher than the set temperature. >> Allowing back-up heater and booster heater to work separately Programming the system to prevent the simultaneous operation of the back-up heater and the booster heater is also possible. An interesting possibility for homes with a limited current amp load! No natural gas or fuel oil connection or exhaust fume channel required.

Your customers with a solar boiler can enjoy wonderful hot water at any time, even when the sun is not shining? An integrated re-heater is included in the system to help the sun on cloudy days.

4 - SOLAR KIT

SOLAR Thermal BOILER
Averaged over an entire year, the sun delivers half of the energy we need to bring our domestic water up to the desired temperature for free. Your customer can use this solar energy by connecting a solar boiler to the Daikin Altherma system. A solar boiler is a thermal solar-energy system, whereby solar rays are transformed into heat. The heat is then stored in a water supply tank.

SOLAR KIT

Daikin Altherma solar boiler assembly
>> >> >> >> >>
Solar collector (to be supplied by the installer) Plumbing network and solar pump station (to be supplied by the installer) Supply tank: standard Daikin Altherma domestic hot water tank Solar kit Re-heater (Daikin Altherma heat pump unit, which also provides the home with heating)
1. Solar collector (Flat plate collector) (Field Supply)

2. Hydrobox

3. Domestic Hot Water Tank

4. Solar kit

5. Solar pump station (Field Supply)

5 - THE ROOM THERMOSTAT

The large LCD screen on the room thermostat indicates all the necessary information regarding the setting of the Daikin Altherma system in a blink of an eye. The user can also easily navigate between the different menus whose most common functions and modes include:
Setting the temperature of the room based on measurements from the built-in sensor Cooling and heating mode Off function (with integrated frostprotection function) Vacation function mode Comfort and reduced function modes Time (day and month) Programmable weekly timer with 2 standard and 5 pre-set programs Keylock function Setting limits. The installer can change the upper and lower limits
Functions Heating only Heating and cooling Comfort function mode Reduced function mode Scheduled function mode Number of setpoint changes Holiday function mode Off function Setpoint limitation Keylock function
>> >> >> >>
Wired room thermostat EKRTWA

12/day

Did you know that
Daikin has set up a number of monitoring sites (in Europe, Oregon, New Hampshire, Alaska,.), where Daikin Altherma has been tested under totally different climate conditions. High satisfaction has been achieved with increased comfort, stable indoor temperature, low energy consumption and hot water always available. whatever the weather conditions at the monitoring site. 17

UNIQUE BENEFITS

Control customized to your customer The water temperature changes in function with the outside temperature so that your customer can enjoy a stable level of heating at any time. As the installer, you set up the system according to the desires of your customer. You input four temperatures to determine the heating curve and in doing so, you perfectly tune the Daikin Altherma system to the type of home. Automatic re-start after power interruption In the event of a power interruption of up to two hours, the system automatically resumes with the previously set parameters. Quiet operation The outdoor unit makes hardly any noise thereby leaving your customers (and the neighbors) peace and quiet undisturbed. You can even set the outdoor unit to produce 10dB(A) less noise during the night. Electric back-up heating Every Daikin Altherma system is equipped with a backup heater (heating capacity of 3 or 6 kW). This unit can be used for supplemental heating during extremely cold outdoor temperatures or as a back-up in case of any problems with the outdoor unit. Your customer can then enjoy comfortable heating at any moment. The operation of the back-up heater can be coupled to the outside temperature. The back-up heater will then only operate when outside temperatures are extremely low.

with a Daikin Altherma heat pump, the temperature of the domestic water can go up to 185F, the temperature of the hot water for heating ranges between 59F and 131F and the temperature of the cold water for cooling between 41F and 72F. 18

4.ECONOMICALLY

Customers today are, more than ever, conscious of the cost of heating. There is not only the increasing cost of fuel oil and natural gas, but also the limited supply of fossil fuels and the problem of CO2 emissions. Energy efficient heating solutions are gaining in popularity. Daikin Altherma debuted in Europe in 2006 and since then has demonstrated significant economical advantages over traditional systems as highlighted on the following graphics.
1. 66 To 80% Additional Heat
A heat pump boiler works more efficiently and saves more energy than a traditional heating system using fossil fuel. Daikin Altherma generates at least 3 to 5 kW of additional heat per 1kW of electricity used. Talk about a good investment.
2. PER (primary energy ratio)
This is the relationship between the useable energy generated and the primary energy consumed, with consideration for the electricity production efficiency and the electricity distribution.

OPERATING COSTS:

Conditions: Required annual heating energy: 20,000 kWh. Source: Energy prices based on EUROSTAT statistics [first semester 2007].
LOW PRIMARY ENERGY CONSUMPTION
Conditions : For combustion systems, the PER indicates the overall efficiency of the system, while for heat pumps it is equal to the seasonal performance factor multiplied by the electricity production efficiency which on average is 0.4 in the European Union.

100% 68% 82%

Daikin Altherma air / water heat pump boiler Gas boiler Fuel oil boiler
A small amount of ventilation in highly insulated houses provides for a healthy interior environment. The principle is simple: fresh air enters and contaminated air is removed. In total, there are 4 ways in which air can be introduced and removed. But there is only one that is energy efficient, and that is ventilation with heat recovery. A maximum amount of energy is recuperated from the contaminated air and transferred to the fresh air. By equipping the home with a ventilation system that includes heat recuperation, the heating requirement decreases and the quality of the home increases.
Average annual CO2 emissions
Altherma TM 2660 (5865 lb/yr)
Gas boiler 4344 (9576 lb/yr) Fuel oil boiler 6045 (13327 lb/yr)

kg/year

(3000) lb/yr (6000) lb/yr (10000) (13000) lb/yr lb/yr
Calculation based on data from Eurelectric (organisation of European electricity producers), Eurelec Progam - 2001 for EU27

LOWER CO2 EMISSIONS

Daikin Altherma produces no direct CO2 emissions, so you personally contribute to a better environment. The system does use electricity, but even without renewable electricity the CO2 emissions are still much lower than boilers that use fossil fuels. 19
5.TECHNICAL SPECIFICATIONS
Daikin Altherma split type APPLICATIONS
1. Application heating only with a room thermostat connected to the indoor unit

1. 2. 3. 4. 5. 6. 7.

Outdoor unit Hydrobox Heat exchanger Pump Valve Manifold (field supply) Valve (Under) floor heating loop (field supply) Room thermostat

FHL13 T

2. Application heating and production of domestic hot water The temperature in each room is regulated by a valve on every water circuit. Hot water for domestic use is delivered by the domestic hot water tank connected to the indoor unit.
Outdoor unit Hydrobox 3. Heat exchanger 4. Pump 5. Valve 6. Manifold (field supply) 7. Valve 8. Motorized 3-way valve 9. Pressure relief valve 10. Booster heater 11. Heat exchanger spiral 12. Tank for domestic hot water

1. 2. FHL13 T

(Under) floor heating loop (field supply) 13 Individual room thermostat

TECHNICAL Specifications

3. Application heating/cooling via room thermostat and production of domestic hot water Heating using under floor heating loops and fan coil units. Cooling using only the fan coil units. Hot water for domestic use is delivered by the domestic hot water tank connected to the indoor unit.
Outdoor unit Hydrobox 3. Heat exchanger 4. Pump 5. Valve 6. Manifold (field supply) 7. Valve 8. Motorized 3-way valve 10. Booster heater 11. Heat exchanger spiral 12. Tank for domestic hot water 13. Motorized 2-way valve (field supply)

1. 2. FCU13 FHL13 T

4. Bi-valent application
Fan coil unit (field supply) (Under) floor heating loop (field supply) Room thermostat with cooling / heating switch

Outdoor unit Hydrobox 3. Heat exchanger 4. Pump 5. Valve 6. Manifold (field supply) 7. Valve 8. Motorized 3-way valve 10. Booster heater 11. Heat exchanger spiral 12. Tank for domestic hot water 14. Alternate heating device (field supply) 15. Aquastat (field supply) 16. Valve (field supply) 17. One-way valve (field supply)
(Under) floor heating loop (field supply) K1A Relay for activating EKHB*unit (field supply) K2A Relay for activating hot water tank (field supply) T Room thermostat 21
Daikin Altherma monobloc APPLICATIONS
Unit Heat exchanger Pump Shut-off valve Collector (field supply) Floor heating loop (field supply) Room thermostat (field supply) User interface

FHL13 T I

2. Application heating and production of domestic hot water The temperature in each room is regulated by a valve on every water circuit. Hot water for domestic use is delivered by the domestic hot water tank connected to the unit. Unit 2. Heat exchanger 3. Pump 4. Shut-off valve 5. Collector (field supply) 6. Motorized 3-way valve 7. By-pass valve (field supply) 8. Booster heater 9. Heat exchanger coil 10. Domestic hot water tank
Floor heating loop (field supply) T 13 Individual room thermostat (field supply) M 13 Individual motorized valve to control loop FHL1 (field supply) I User interface
3. Application heating/cooling via room thermostat and production of domestic hot water Heating using under floor heating loops and fan coil units. Cooling using only the fan coil units. Hot water for domestic use is delivered by the domestic hot water tank connected to the unit. Unit 2. Heat exchanger 3. Pump 4. Shut-off valve 5. Collector (field supply) 6. Motorized 3-way valve 8. Booster heater 9. Heat exchanger coil 10. Domestic hot water tank 11. Motorized 2-way valve (field supply)

1. FCU13

Fan coil unit (field supply) FHL13 Floor heating loop (field supply) T Room thermostat with cooling/heating switch (field supply) I User interface
4. Application heating/cooling without a room thermostat but with a heating only room thermostat controlling the underfloor heating and a cooling/heating thermostat controlling the fan coil units. 1. Unit 2. Heat exchanger 3. Pump 4. Shut-off valve 5. Collector (field supply) 6. By-pass valve (field supply) 11. Motorized 2-way valve to shut off the floor heating loops during cooling operation (field supply) 12. Motorized 2-way valve for activation of the room thermostat (field supply)

Fan coil unit with thermostat (field supply) FHL13 Floor heating loop (field supply) T Heating only room thermostat (field supply) T4.6 Individual room thermostat for fan coil heated/cooled room (field supply) I User interface 23
Function Leaving water temperature range Drain valve Material Color Dimensions (Net) Weight (Net)
Factory mounted heater Volume Max. water pressure Pre Pressure Capacity
EKHBH054BA3VJU Heating only Heating Cooling F F -
EKHBX054BA3VJU Reversible
EKHBH054B6VJU Heating only 77 - 131* yes
EKHBX054B6VJU Reversible 41 - 71.6

77 - 131* 41~71.6

Epoxy polyester painted galvanized steel Neutral white (RAL 9010) HxWxD in. lbs.
36 5/16 x 19 3/4 x 14 7/5/16 x 19 3/4 x 14 7/5/16 x 19 3/4 x 14 7/5/16 x 19 3/4 x 14 7/208-230V/1Ph/60Hz 208-230V/1Ph/60Hz 2.64 43.5 14.1/4 Male BSP 1 1/4 43.5 1.45 5/8 3/- 131 7.6 0.26 4.23/15.32 8.48 6.3 0.26 4.23/15.32 10.59 5.08 0.26 4.23/15.32 12.13 9.93 6.79 0.26 4.23/15.32 12.13 9.93 9.46 5.08 6.79 7.1 0.26 4.23/15.32 10.59 9.46 7.58 6.3 7.1 8.1 0.26 4.23/15.32 8.48 7.- 71.6 7.6 8.2 208-230V/1Ph/60Hz 2.64 43.5 14.1/4 Male BSP 1 1/4 43.5 1.45 5/8 3/- - 71.208-230V/1Ph/60Hz
Capacity Steps Power supply gal. PSI PSI in. in. PSI gal. in. in. F F

Heating Cooling

Main components

Expansion vessel

Piping connections diameter
When connected to all outdoor units

Water circuit

Piping Safety valve Total water volume
Refrigerant Gas side diameter circuit Liquid side diameter Operation range Waterside Pump Heating Cooling Nominal ESP unit
PSI PSI gal. GPM GPM GPM PSI PSI gal. GPM GPM GPM PSI PSI gal. GPM GPM GPM
When connected to ERLQ036

Water volume

Water side Heat exchanger

Water flow rate Min./Max

Water flow rate Nom.
Heating Cooling Heating Cooling

Nominal ESP unit

When connected to ERLQ048
When connected to ERLQ054
Water volume Water flow rate Min./Max Water Heating flow rate Cooling Nom.
*Back up heater operation between 59F and 77F

TECHNICAL SPECIFICATIONS

outdoor unit Outdoor
Nominal capacity Nominal input COP EER Fan Motor Model Output Heating Operation range Cooling Domestic water Sound power level Sound pressure level Air Flow Rate (nominal at 230V) (cfm) Liquid (OD) Gas Drain Piping connections Piping Length Heating Cooling Heating Cooling Heating Cooling Type Diameter (OD) Type Diameter (OD) Type Diameter (OD) Minimum Maximum Equivalent Chargeless

Installation Height Maximum Difference
ERLQ036BAVJU MBh MBh kW kW 38.2 47.6 2.58 3.91 4.34 12.17 W F F F dBA dBA dBA dBA

m3/min m3/min

ERLQ048BAVJU 47.8 59.1 3.30 5.94 4.24 9.95 Brushless DC motor 70 -4 - - 114.8 -4 - 109.4*
ERLQ054BAVJU 54.6 60.6 3.97 6.94 4.03 8.73

3/8 5/16.312 98.4 98.4

Flare connection 3/8 Flare connection 5/8 Hole 1 16.312 98.4 98.4 8.15 208-230V/1Ph/60Hz 1/16 x 35 7/16 x 12 5/8
in. in. in. in. in. ft. ft. ft. ft. ft. lbs. A
Refrigerant charge Power supply Recommended fuses Dimensions (Net) Weight (Net)

R-410A

Measuring conditions: Heating Ta DB/WB 44.6F/42.8F - LWC 95F (DT=41F) - Cooling Ta 95F - LWE64.4F (DT=41F) * Booster heater operation from 95F onwards (1) These conditions are based on under floor heating/cooling application

monobloc OUTDOOR UNIT

SINGLE PHASE Nominal capacity Nominal input COP EER Heating Operation range Cooling Domestic water Sound power level Sound pressure level Refrigerant charge Power supply Recommended fuses Dimensions (Net) Weight (Net) HxWxD A in. lbs. Heating Cooling Heating Cooling R-410A F F F dBA dBA dBA dBA lbs. Heating Cooling Heating Cooling MBh MBh kW kW 38.2 2.59 4.32 -

Heating only

Reversible
With bottom plate heater EDLQ036BA6VJU EDLQ048BA6VJU EDLQ054BA6VJU EBLQ036BA6VJU EBLQ048BA6VJU EBLQ054BA6VJU 47.8 3.33 4.- 95 (1) 5 - 95 (1) (2) 6.5 208-230V/1Ph/60Hz 27/32 x 56 1/2 x 15 1/54.6 3.93 4.07 38.2 43.8 2.59 3.91 4.32 11.20 47.8 54.5 3.33 5.79 4.20 9.- 95 (1) 50 - 114.- 95 (1) (2) 6.5 208-230V/1Ph/60Hz 27/32 x 56 1/2 x 15 1/54.6 57.0 3.93 6.43 4.07 8.86
Measuring conditions: Heating Ta DB/WB 44.6F/42.8F - LWC 95F - Cooling Ta 95F - LWE64.4F (1) E(D/B)L* models can reach -4F but without capacity guarantee (2) Booster heater operation from 95F onwards (3) These conditions are based on under floor heating/cooling application

domestic hot water tank

EKHWS050BA3VJU Water volume Max.water temperature Max.water pressure Height Diameter Booster heater

Water inlet H/E Diameter

EKHWS080BA3VJU 79.145
gal. F PSI in. in. kW in. in. in. A A
Water outlet H/E Diameter in. Cold water in Diameter Hot water out Diameter
Insulation (Polyurethane foam) Min. thickness in.
1 37/1/1/3/4 FBSP 3/4 FBSP 3/4 FBSP 3/4 FBSP 208-230V/1Ph/60Hz Stainless steel (DIN 1.4521) Epoxy-coated mild steel Neutral white 63

Piping connections

Nominal running current Fuse Power supply Material inside tank Material outside casing Color Dimensions (Net) Empty weight HxWxD Size

in. lbs.

45 9/32 x 22 27/32 x 22 27/x 22 27/32 x 22 27/129.8
EKSOLHWBAVJU pressure drop max.inlet temp Heat exchanger
heat exchange capacity Logarithmic mean temperature difference (LMTD)

psi F W/K K

Pump Water circuit Ambient temperature Power supply Power supply intake Dimensions (Net)

Number of speeds

Power input

W in. F F

46 3/4 FBSP 95 33.8 208-230V/1Ph/60Hz from indoor unit

max. min.

30 1/32x12x10 1/32

ROOM THERMOSTAT

EKRTWA Ambient temperature Temperature setpoint range Storage Operation Heating Cooling F F F F -4 - - 122 39.2 - 98.6 39.2 - 98.6 yes proportional band HxWxD in lbs. 87x125x34 0.47

thermostat

Clock Regulation function Dimensions (Net) Weight (Net)

6.THE SOFTWARE

Daikin Althermas simulator software program allows quick and easy indication of the benefits of a Daikin Altherma system. By specifying a number of parameters such as the location, the surface area to be heated, the required heating capacity, the entry and exit water temperatures of the distribution network and the local energy prices, the program displays the following simulation details.
1. Material list with technical specification 2. Simulation graphics: a) Required and available heating capacity with indication of the SPF (or Seasonal COP) b) Duration of the heating period as a function of the outside temperature c) The annual energy cost compared with a heating system using gas or fuel oil d) The annual amount CO2 emitted in tonnes compared with a heating system using gas or fuel oil e) The monthly energy consumption in kWh f) The monthly energy cost in dollars g) The total amount of thermal energy in kWh as a function of the outside temperature h) The radiated heat per ft2 (in Btu/ft2) per month All data is collected in a separate report. If you are interested in this software, contact your local Daikin Altherma distributor

Energy consumption (kWh)

Heat pump day Heat pump night Electrical element day
0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

Electrical element night

WARNINGS
Always use a licensed installer or contractor to install this product. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. se only those parts and accessories supplied or specified by Daikin. Ask a licensed contractor to install those parts and accessories. Use of U unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.
ead the Users Manual carefully before using this product. The Users Manual provides important safety instructions and warnings. R Be sure to follow these instructions and warnings. For any inquiries, contact your local Daikin sales office.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
2009 Daikin Industries, Limited. Daikin Daikin AC Absolute Comfort, and Daikin Altherma are registered trademarks of Daikin Industries, Limited. All rights reserved. ,
Daikin AC (Americas), Inc.
1645 Wallace Drive, Suite 110 Carrollton, TX 75006 USA www.daikinac.com 866-4DAIKIN 972-245-1510

Dealer Information

PCAWUSE09-09B
Daikins products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations.

doc1

DAIKIN ALTHERMA DELIVERS DESIRED FOOTPRINT. BOTH LITERALLY AND FIGURATIVELY

The Challenge

Oregon locals embarking upon building the most sustainable energy efficient home possible, wanted a heating solution worthy of their green vision.
Portland, Oregon consistently ranks among Americas greenest cities. In fact, a recent Popular Science magazine study rated it the countrys greenest city. So when Dawn Bauman and Wendy Broussard set out in February 2007 to build a home in Portlands Collins View neighborhood, their quest to make it as sustainable, energy efficient, and eco-friendly as possible wasnt out of the ordinary. However, one eco-friendly aspect of the home would turn out to be unique so unique in fact, the homeowners have only halfjokingly considered putting a guest book in their mechanical room. Bauman and Broussard ended up with the first installation of the Daikin Altherma system in the U.S. and a tremendously eco-friendly heating and hot water supply solution resulting in multiple tours of the homes mechanical room. We are strong believers that living on this planet is a privilege and we need to be good stewards of it. Although we all have footprints we leave behind we decided ours could be just footprints and not dents left on the environment, Bauman said.

Daikins Solution

The first U.S. installation of Daikin Altherma - a domestic heating and hot water solution providing outstanding performance even during the coldest months.
Application: Residential Location: Portland, Oregon USA
The Bauman-Broussard home, which received a LEED Platinum rating, is the site of the first installation of Daikin Altherma in North America.
MANY DEMANDS, FEW SOLUTIONS
Bauman and Broussard began the project in winter 2007 by interviewing several architectural firms, focusing on ones with green building expertise. They selected Constructive Form Architecture and Design, LLC, a young/start-up firm whose members have environmentally supportive design experience throughout the U.S. and Europe. Brent Hinrichs, architect with Constructive Form, explained the homeowners were intent on selecting as many green options as made sense for them. This involved extensive research and discussions since the design intent was to use a minimal amount of energy and the most efficient (though not cost prohibitive) systems available, in conjunction with reducing the overall electric and heating loads for the project as a starting point, Hinrichs said. The air-to-water heat pump was the preferred option.otherwise we would have been looking at a solar thermal preheat for a modulating electric boiler system given the goal of eliminating fossil fuel, he recalled. Hinrichs and his Constructive Form co-owners, Simone Goldfeder, designer, LEED AP and Kina Voelz, architect, LEED AP, discovered none of the North American air-towater heat pump systems under
development were available at the time. They also learned the other existing systems had lower efficiencies especially at winter temperatures.
was specified. Daikin was very responsive and engaged in identifying potential test sites for the Daikin Altherma system in North America, Hinrichs recalled.
The air-to-water heat pump was the preferred optionotherwise we would have been looking at a solar thermal preheat for a modulating electric boiler system given the goal of eliminating fossil fuels. Brent Hinrichs, Architect

Constructive Form

A NORTH AMERICAN FIRST
Daikin has more than 50 years of experience with heat pumps and provides more than a million of them to homes and commercial applications each year, so while Daikin Altherma was new to North America,
Thus, they contacted every international manufacturer they could find via the Internet, and found Daikin Altherma was an all-electric system with a variable speed inverter compressor providing a high coefficient of performance while delivering the sought after combined/ integrated hydronic and domestic hot water functionality. The Daikin Altherma system consists of 2 main They worked with components (outdoor unit and hydrobox) that can the local Daikin AC also be combined with optional accessories such office and when Daikin as a water tank and solar thermal kit to ensure officials approved the ideal water temperature. home as an introductory test-site for the everyone involved in the project continental U.S., Daikin Altherma confirmed that a proven history of

performance and efficiency was the most important aspect of its selection for the job. Broussard and Bauman were fairly active in the design of the home, and at one point seriously considered using only a wood stove for heating. But they didnt warm to the idea of starting a fire each morning for warmth. We knew we wanted in-floor radiant heating but we never really had to pursue other brands of systems, thanks to the guidance from our architect/design firm, Bauman said. Construction started in May 2008. The HVAC contractor selected for the job, Jacobs Heating & Air Conditioning, is the Portland areas largest Daikin Network Alliance (DNA) partner and had extensive experience with other Daikin products. The radiant heating system, which has four zones and runs throughout the 1.5-story, 1,820 square-foot home, was one of the first aspects of the mechanical system to be installed. Brian Erdahl, lead technician at Jacobs, explained all of the radiant floor tubing was run to the remote manifolds in the walls and some panel radiators were oversized, so they could match the BTUs needed with 120F water. Next, the contractor ran supply and return feed lines to the mechanical room to supply the radiant floor and panel heaters in four separate zones. After the plumber installed the
plumbing lines and everything was roughed in, the Daikin Altherma outdoor unit and the Hydrobox (Daikins indoor unit containing the refrigerant/water heat exchanger) were set for installation. A heat recovery ventilator was also installed to control the fresh air entering the house and works hand in hand with Daikin Altherma for outstanding efficiency and air quality. While there were some European-to-U.S. voltage and metric-to-standard conversion challenges, they were all overcome fairly quickly and easily. Additionally, Jacobs had to work with the city of Portland
for approval of the unit since there was an ETL listing, but no applicable AHRI testing and rating program. But, Erdahl said the city officials were more than happy to let a system this efficient go into a home in the Portland area and they were great to work with.

EFFICIENCY UNDER CONTROL

Daikin Altherma provides the ability to intricately monitor and manipulate system performance, and features an automatic control system adjusting the systems operation to varying ambient conditions. It can basically be tuned to suit the homeowners exacting requirements, and also
FLEXIBILITY IS EVERYTHING

Daikin Altherma is flexible enough to be applied in many types installations new or retrofit. Daikin Altherma can be connected to:
standard low temperature radiators under- floor heating fan coil units
Standard low temperature radiators deliver comfortable heating in the BaumanBroussard home.
Bauman and Broussard ended up with the first installation of the Daikin Altherma system in the U.S. - a tremendously eco-friendly heating and hot water supply solution.
features an automatic re-start feature in the event of a power interruption. Additionally Daikin Altherma system can be equipped with a back-up heater (in a refurbishment type application, Daikin Altherma can reuse an existing boiler installation) that can be used for supplemental heating during extremely cold outdoor temperatures or as a backup to the outdoor unit. The homes control system was set up so the thermostat calls for heat, opens the valve, and turns the circulation pump on, but the pump will only run when necessary. Thus, the
homeowners are not paying for the pump to check water temperatures when they are in the nonheating season. Another benefit offered by Daikin Altherma is that it operates extremely quietly as low as 49 dB(A) and can even be set to produce 10dB(A) less noise during the night. In addition to Daikin Altherma, and a host of other eco-friendly initiatives such as installation of a 2.4 kW solar photovoltaic system enhanced energy savings considerably. The homeowners are actually selling power back to the grid, and providing all of their domestic hot water with the use of Daikin Altherma via the solar photovoltaic panel array. The house was also preplumbed for future solar thermal inputs and there is a potential for using a reverse-cycle to provide chilled water for partial tempering of the floor during cooling season. Efforts like this earned the home which was completed in February 2009 Platinum certification under the United States Green Building Councils LEED for Homes Pilot Program. And while that certification certainly hinged on several components, Daikin Altherma
played an instrumental role. Bauman and Broussard have been surprised at the number of people who have asked them where they can get the Daikin Altherma system in the U.S. However, they say the best surprise is the efficiency. Our electric bill is amazingly low for the size of the house and the fact that the entire house runs on electricity alone.
Our electric bill is amazingly low for the size of the house and the fact that the entire house runs on electricity alone.
Dawn Bauman Wendy Broussard , Owners

DAIKIN ALTHERMA

All-in-one, all year round heating, cooling and domestic hot water supply solution
Daikin Altherma is an innovative system that heats, produces domestic hot water and can even cool spaces. Daikin Altherma delivers maximum comfort the whole year through. These heat pumps are an alternative to conventional gas or fuel oil heating.

the water distribution system raise the temperature of domestic (under floor heating, low hot water, cutting on both CO2 emissions and operating costs. temperature radiators and/ or fan coil units) in the home via a Daikin Altherma is flexible heat exchanger. enough to be configured in Depending on the model and several ways: ENERGY EFFICIENT OPERATION the conditions, the Daikin The air-to-water heat pump from Altherma air-to-water heat pump Space Heating Only Daikin uses a sustainable energy delivers between 3 and 5 kWh of Space Heating and usable heat for every 1 kWh of source. In fact, it extracts heat Domestic Hot Water electricity it uses. from the outside air. Production Daikin Altherma can be The system consists of a Space Heating and configured for use in both new closed circuit containing R-410A Domestic Hot Water and refurbishment applications, refrigerant. A thermodynamic Production with Solar and connects to standard low cycle is created through Space Heating temperature radiators, under floor evaporation, condensation, Space Cooling, Space heating or fan coil units. In compression and expansion. A Heating, Space Cooling combination with a solar thermal heat pump pumps heat from a and Domestic Hot Water set-up, Daikin Altherma uses low to a high temperature level. Production The heat raised is transferred to thermal energy from the sun to
Daikin Altherma use renewable energy sources (such as outside air) Daikin Altherma delivers considerable savings in energy Daikin Altherma delivers a significant contribution in the fight against CO2 emissions Daikin Altherma can provide heating, cooling and domestic hot water
Manufacturer Daikin AC Christina Trondsen 1645 Wallace Street, Suite 110 Carrollton, TX 75006 972-245-1510 www.daikinac.com Architect/Building Design Constructive Form Architecture & Design Brent Hinrichs 2975 SW Upper Drive Portland,OR 97201 503-297-5890 info@constructiveform.com
HVAC Contractor Jacobs Heating & Air Conditioning 4474 SE. Milwaukie Ave. Portland, OR 97202 www.jacobsheating.com Builder Ierulli Construction 13851 SW Alpine View Ct Tigard, OR 97224 503-572-4250
Bauman Broussard Home Daikin Altherma Indoor Section - Hydrobox (EKHBX016AB6V3) Outdoor Section - Condensing Unit (ERHQ011A) Domestic Hot Water Tank (EKHWS200B3Z2) (52.8 gallons) Featured Eco- friendly Aspects included: Low-VOC paint and formaldehyde-free glues Recycled paper and resin countertops Compact fluorescent lights Solar-powered landscape lighting Pervious concrete driveway 100% of storm water treated on-site Reflective metal roof Rainwater collection for site irrigation Flow-through planters Site restoration Native landscaping Highly efficient plumbing fixtures

Daikin Equipment

Daikin AC offers North America intelligent heating and air conditioning solutions with superior energy performance and sophisticated design. These advanced systems fall under the Daikin Altherma, Quaternity, VRV, VRV-S and SkyAir product names. The company located in Carrollton, Texas, is owned by the Japanese-based Daikin Industries, Ltd. For more information, call 866-4DAIKIN or visit www.daikinac.com.
Private Residence Portland, Oregon USA

CSAWUSE09-09R

 

Tags

Wixl 85 42LG3000-ZA AEU VRD-MC5 Casio System Vision Coffee MPC500 Monobloc AL2423W Edition 2011 RL36ebsm Classic 32PFL7603D 12 XR-1853MK2 Catalogue 2007 ZWG3165 FFH-185AD UE40C5000 WD-10180TP VSX-D859TX XL2370 Sims 2 Usa WM-GX400 Officejet 9110 KX-TCD320E MC-200-22 Cost IC-M401E 895 EX EP720I HBH-662 KD-36XS955 Router DEP-3 Wl-354 3SF-6C NWZ-W202 DMC-FZ5PP CX6330 Logicom G302 LS-Q096AAL Motorola H375 Brabus DSP110 NAD HTR3 DCR-DVD308 5140I HT-EV100 226BW Z8240 MO6 Mo8 VG-99 L246WH-BN EB-GD93 950 Live QC5055 00 A-90 EX 50 R ZMZ28 X2I Twin RH399D Alive PDP-505SL TOB-195 RDR-AT100 HD-hlan DMR-EH595 Selio Price Extensa 2500 Anniversary WM-EX621 Ht Connect Price List Smart Stylus-550WP Installation Manual DSC-TX1 L 802 11B DCR-DVD803 RX-V463 NP6330 NAS-D500HD DSP256XL Sbcru530U Vapeur Portege 7020 Us DVP5286K 98 DS7000 DP-1050 Diablo DVF-8945N RFG297aars XAA M-400 Dvdr520H SC-MX20R SA-AK20 L50210 DVD-HD850B The Room EPL-N2050 Hitman 2 RSE8kpps BBA 2865 Pc T91

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101