Honeywell RTH5100B
Honeywell International RTH5100B1025K Digital manual ThermostatThe Honeywell RTH5100B1025 digital non-programmable thermostat is designed to give you many years of reliable service. It features easy-to-use, push button climate control. The RTH5100B1025 non-programmable thermostat features settings that are permanently stored in memory and do not require battery power. Large, Clear Backlit Display The Honeywell RTH5100B1025 digital non-programmable thermostat comes with a large, clear, backlit display that is easy to read, even in the dark. Fast, Easy Batter... Read more
Details
Brand: HONEYWELL
Part Numbers: 122354, 4369625, 462252, RTH5100B1025, RTH5100B1025/A, RTH5100B1025/K, RTH5100B1025K
UPC: 00085267338509, 0085267338509, 085267338509
[ Report abuse or wrong photo | Share your Honeywell RTH5100B photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Honeywell RTH5100B, size: 631 KB |
Honeywell RTH5100B
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

RTH5100B Non-programmable Thermostat
INSTALLATION INSTRUCTIONS
The RTH5100B Thermostat provides electronic control of 24 Vac singlestage heating and cooling systems or 750 mV heating systems.
START HERE
For assistance with your Honeywell product, please visit www.honeywell.com/yourhome or call Honeywell Customer Care toll free at 1-800-468-1502.
Read and Save these Instructions
U.S. Registered Trademark 2004 Honeywell International Inc. All Rights Reserved Patents Pending
69-1716
Contents
Prepare for Installation..3 Follow Important Instructions..5 Remove Old Thermostat..6 Follow Special Instructions..7 Label Old Thermostat Wires...10 Mount New Wallplate to Wall..11 Connect Wires to New Wallplate..15 Install Batteries...20 Attach New Thermostat to Wallplate..21 Configure Installer Setup...22 Customer Assistance..28 Limited One-Year Warranty..29
Step 1. Prepare for Installation
1. Check that the following items are included:
e Co Settin ol g
WALLPLATE THERMOSTAT MOUNTING SCREWS (2) AND WALL ANCHORS (2) OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS WIRE LABELS CAUTION CARD
Fan Auto Syst Cool On em Cool
OPERATING INSTRUCTIONS INSTA ATION
CAUTION
M22033
If any of the items shown above are missing, call Honeywell Customer Care at 1-800-468-1502 before returning the thermostat to the store.
3 69-1716
Step 1. Prepare for Installation (Cont)
2. Check that you have everything required for the installation: Two AAA alkaline batteries No. 2 Phillips screwdriver and standard pocket screwdriver Drill Drill bit use 3/16 in. for drywall; use 7/32 in. for plaster Level (optional) Hammer Pencil Electrical tape
Step 2. Follow Important Instructions
1. Do not connect the wires to the new thermostat based on wire color because damage can occur to the heating and/or cooling system. These Installation Instructions explain later how to use the enclosed wire labels to correctly mark the wires connected to your old thermostat.
OLD THERMOSTAT
YELLOW WHITE
DO NOT WIRE NEW THERMOSTAT BASED ON WIRE COLOR.
ORANGE
M22034
Step 3. Remove Old Thermostat
1. 2. 3. Turn off power at the heating and/or cooling system or fuse/circuit breaker panel. Remove the cover from the old thermostat. Remove the old thermostat from the wall or wallplate. Do not remove the wires.
WALLPLATE
THERMOSTAT
.18.2.9.7.5 O.25 N G E R.4.3
If you are replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the trash. Contact your local waste management authority for instructions regarding recycling and the proper disposal of an old thermostat containing mercury in a sealed tube.
69-1716 6
MERCURY NOTICE
M22036
Step 4. Follow Special Instructions
1. 2. 3. If you have C and/or C1 wire(s) connected to your old thermostat, do not connect them to your new thermostat. Disconnect the C and/or C1 wire(s). Make sure they do not touch each other or any other wires. Wrap the bare end of each C and/or C1 wire(s) with electrical tape.
LETTER DESIGNATION SCREW TERMINAL
WIRE HOLE DO NOT CONNECT TO NEW THERMOSTAT
M22037
Step 4. Follow Special Instructions (Cont)
4. Most installations have two to five wires connected to the old thermostat. If six or more wires are connected to your old thermostat (not counting the C or C1 wires), do not continue the installation. You may have purchased the wrong thermostat. Visit www.honeywell.com/yourhome or call Honeywell Customer Care at 1-800-468-1502 before returning the thermostat to the store.
G W2 Y2
WIRE HOLE SIX WIRES CONNECTED
M22038
5. 6. If you find any wires not connected to your old thermostat, do not connect them to your new thermostat. Wrap the end of the wires that are not connected with electrical tape.
G R RC
WIRE WIRE HOLE WIRES NOT CONNECTED DO NOT CONNECT TO NEW THERMOSTAT M22040
Step 5. Label and Disconnect Wires from Old Thermostat
Step 5. Label Old Thermostat Wires
1. As you disconnect each wire, use the enclosed wire labels to wrap a wire label around each wire that matches the letter designation. Do not allow the wires to fall into the wall opening after the wires are disconnected. Remove any remaining parts of the old thermostat from the wall.
WIRE LABEL LETTER DESIGNATION SCREW TERMINAL
WIRE HOLE
M22039
When connecting the wires to the new thermostat, refer to the wire labels. Do not connect wires to your new thermostat based on the color of the wire.
69-1716 10
Step 6. Mount New Wallplate to Wall
1. Separate the wallplate from the thermostat as shown.
THERMOSTAT WALLPLATE WIRE HOLE
M22042
Step 6. Mount New Wallplate to Wall (Cont)
2. Pass the labeled wires through the wire hole on the wallplate.
WALL OPENING WALLPLATE WIRE HOLE
RC R Y
NOT USED
LABELED WIRES
M22043
3. Position the wallplate on the wall with the arrow pointing up. Level the wallplate (for appearance only) and mark the two mounting holes with a pencil.
PLACE LEVEL ON TABS
MARK MOUNTING HOLES (2)
M22044
4. 5. Move the wallplate aside and drill holes at the locations marked on the wall. Drill 3/16 in. holes for drywall or 7/32 in. holes for plaster. Tap the wall anchors into the drilled holes until even with the wall surface.
DRILLED HOLES (2) WALL ANCHORS (2)
MOUNTING SCREWS (2)
M22046
Position the wallplate over the wall anchors. Insert the mounting screws into the wall anchors. Check leveling, if desired, and tighten the mounting screws.
Step 7. Connect Wires to New Wallplate
1. 2. 3. Match the labeled wires to the letter designations on the wallplate. If wires are to be connected to both Rc and R, loosen the Rc and R screw terminals and remove the metal jumper. If only one of the terminals, Rc or R, is to be connected, leave metal jumper in place.
METAL JUMPER TERMINAL BLOCK SCREW TERMINALS LETTER DESIGNATIONS
RC R Y W/O/B G
O/B W G
M22180
Step 7. Connect Wires to New Wallplate (Cont)
4. Loosen the screw terminals. Insert the labeled wires into the holes on the right side of the terminal block that match the letter designations. Tighten the screw terminals. If any of the labeled wires do not match the letter designations, see next page for wire connections.
LABELED WIRES TERMINAL BLOCK SCREW TERMINALS LETTER DESIGNATIONS
INSERT WIRE IN HOLE
M22176
6. Compare letter designations on your old and new thermostats.
New Possible letter designations Thermostat on the labeled wires
RC or R
R or RH, 4, V
Y or Y1, M
Y NOT USED
W or W1, H, O, B
G or F
C or X, B
Do Not Connect
M22055
Do not connect more than one wire to each terminal. Be sure to read the notes referenced in the numbered triangles above. These numbered notes appear on the next page.
NOTES 1 If wires will be connected to both RC and R on the new thermostat, remove metal jumper between RC and R. Leave metal jumper in place if only one of the terminals, RC or R, will be connected on the new thermostat. 2 If wires were connected to both R and RH terminals on the old thermostat, remove metal jumper between RC and R on the new thermostat. Connect the old R to the new RC and the old RH to the new R. 3 Do not connect both O and B when wiring to a heat pump. Connect O to O/B W. Wrap the bare end of the B wire with electrical tape and do not use. 4 Transformer common. Wrap the bare end of the wire with electrical tape and do not use.
M22050
7. Push excess wire back into the wall opening. Keep wires in the shaded area.
WALL OPENING SHADED AREA
M22054
Step 8. Install Batteries
1. Install two fresh AAA alkaline batteries on the back of the thermostat as marked on the battery holder.
BACK OF THERMOSTAT
BATTERY HOLDER BATTERIES
M22056
After the thermostat is mounted on the wallplate, the thermostat does not require removal from the wallplate to replace the batteries. Refer to the enclosed Operating Instructions (69-1722) for more information on the removable battery holder.
69-1716 20
Step 9. Attach New Thermostat to Wallplate
1. Align the four tabs on the wallplate with the four slots on the back of the thermostat.
WALLPLATE TABS
NOT USED O/B W
SLOTS ON BACK OF THERMOSTAT
M22057
Push the thermostat straight onto the wallplate until it snaps into place. Turn on the power at the heating and/or cooling system or fuse/circuit breaker panel. If the wires interfere with mounting the thermostat to the wallplate, push the excess wire back into the wall opening.
21 69-1716
Step 10. Configure Installer Setup
1. Use the Installer Setup Menu to match your new thermostat to your heating and/or cooling system. Follow the steps in this section to set up your thermostat. Enter the Installer Setup Menu by pressing and holding the Up and Fan buttons at the same time, for approximately five seconds, until the screen changes.
Replace Batt
Service Needed
Fan Auto
CoolOn System Cool
M22058
Release the buttons when the display on your thermostat matches the display below.
M22121
10. Configure Installer Setup (Cont)
4. 5. Press the Up or Down button to select your setting for Installer Setup Number 1 in the table below. After you select your setting, press the Next button to go to the next Installer Setup Number.
INSTALLER SETUP NUMBER
SETTING
UP BUTTON DOWN BUTTON NEXT BUTTON
Heating and/or Cooling System Type
Gas, oil or electric heating with central air conditioning. The compressor outside runs in both heating and cooling. Gas, oil or electric heating without central air conditioning. Gas, oil or electric heating without central air conditioning. (Use this setting if you could turn the fan on and off with a fan switch on your old thermostat.)
M22122
Configure Installer Setup (Cont)
6. 7. If you do not have a number 2 on the left side of your display, go to the next page. If you have a number 2 on the left side of your display, press the Up or Down button to select your setting for Installer Setup Number 2 in table below. After you select your setting, press the Next button to go the next Installer Setup Number.
Heat Pump Changeover Valve
Use this setting if you connected a wire labeled O to O/B W terminal. Use this setting if you connected a wire labeled B to O/B W terminal.
M22060
Step 10. Configure Installer Setup (Cont)
9. 10. If you do not have a number 3 on the left side of your display, go to the next page. If you have a number 3 on the left side of your display, press the Up or Down button to select your setting for Installer Setup Number 3 in table below. After you select your setting, press the Next button to go to the next Installer Setup Number.
Fan Control in Heating
Heating system controls fan in a call for heat. Thermostat controls fan in a call for heat.
M22061
12. 13. If you do not have a number 5 on the left side of your display, go to the next page. If you have a number 5 on the left side of your display, press the Up or Down button to select your setting for Installer Setup Number 5 in table below. After you select your setting, press the Next button to go to the next Installer Setup Number.
Heating Cycle Rate
M22062
15. 16. 17. Press the Up or Down button to select your setting for Installer Setup Number 14 in table below. After you select your setting, press the Done button to exit the Installer Setup and save your settings. Congratulations! The installation of the thermostat is complete. Refer to the enclosed Operating Instructions (69-1722) for information on how to operate your new thermostat.
UP BUTTON
Done Next
DOWN BUTTON
DONE BUTTON
Installer Setup Number 14
Installer Setup Name Temperature Display
(Select Your Setting) Settings 0Fahrenheit Temperature Display 1Celsius Temperature Display
M22063
Customer Assistance
For assistance with your Honeywell product please visit www.honeywell.com/yourhome or call Honeywell Customer Care toll free at 1-800-468-1502. Before calling, please have the thermostat model number and date code available.
MODEL NUMBER
xxxxxxxx xxxxxx
DATE CODE
THERMOSTAT BATTERY HOLDER
M22178
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods Dock 4 MN10-Douglas Dr N Golden Valley, MN 55422 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywells sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
Limited One-Year Warranty (Cont)
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limite, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.
Automation and Control Solutions
Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422
Honeywell Limited-Honeywell Limite 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
G.H. 5-04
www.honeywell.com/yourhome

RTH5100B Non-programmable Thermostat
OPERATING INSTRUCTIONS
The RTH5100B Thermostat provides electronic control of 24 Vac single stage heating and cooling systems or 750 mV heating systems.
Operating Instructions
For assistance with your Honeywell product please visit www.honeywell.com/yourhome or call Honeywell Customer Care toll free at 1-800-468-1502.
Read and Save these Instructions
U.S. Registered Trademark 2004 Honeywell International Inc. All Rights Reserved Patents Pending
69-1722
Contents
Features..3 Get to Know Your Thermostat..4 Thermostat...4 Display...5 Operate Your Thermostat..6 Set System Setting..6 Set Fan Setting...7 Change Temperature Setting..8 Replace Batteries..9 Review Battery Tips..13 Built-in Compressor Protection..14 Accessory/Replacement Parts..15 Troubleshooting Tips..16 Customer Assistance..21 Limited One-Year Warranty..22
Features
Large, Clear, Backlit Display: Easy-to-see and readeven in the dark. Precise Comfort Control: 1F of your set temperature. Simplified Operation: Soft-key controls. Simultaneously displays both room temperature and temperature setting. Easy Change Battery Holder. Built-in Compressor Protection: Minimum-off timer protects compressor from restarting too early after a shutdown.
Get To Know Your Thermostat
Get To Know Your Thermostat Thermostat
DIGITAL DISPLAY BATTERY HOLDER LATCH
PRESS TO RELEASE BATTERY HOLDER.
BATTERY HOLDER
e C Sett ool ing
TWO AAA ALKALINE BATTERIES
C Auto Syste oolO n m Coo l
RAISES TEMPERATURE SETTING
TEMPERATURE SETTING BUTTON
TEMPERATURE SETTING BUTTON FAN BUTTON
SELECTS AUTO OR ON LOWERS TEMPERATURE SETTING
SYSTEM BUTTON
SELECTS HEAT, OFF OR COOL
M22010
Get to Know Your Thermostat (Cont) Display
INSIDE TEMPERATURE INDICATES BATTERIES ARE LOW AND MUST BE REPLACED
Inside Replace Batt HeatCool Setting
TEMPERATURE SETTING INDICATES THERMOSTAT IS "CALLING" FOR HEAT OR COOL
Fan On Auto
Heat On Cool On System Heat Cool Off
CURRENT FAN SETTING
CURRENT SYSTEM SETTING
M22011
Operate Your Thermostat Set System Setting
Press the System button to select Heat, Off or Cool: HeatThermostat controls the heating system. OffBoth the heating and cooling systems are off. CoolThermostat controls the cooling system.
CAUTION
Equipment Damage Hazard. Air conditioning compressor damage possible. Do not operate cooling system when outdoor temperature is below 50 F (10 C).
Service Needed
Fan Auto
CoolOn Cool
PRESS THE SYSTEM BUTTON TO SELECT HEAT, OFF OR COOL
M22012
Operate Your Thermostat (Cont) Set Fan Setting
Press the Fan button to select Auto or On: AutoNormal setting for most homes.The fan runs only when the heating or cooling system is on. OnThe fan runs continuously. Use this setting for improved air circulation or for more efficient air cleaning.
PRESS THE FAN BUTTON TO SELECT AUTO OR ON
M22013
Operate Your Thermostat (Cont) Change Temperature Setting
Press the Up or Down button to select the desired temperature setting.
TEMPERATURE SETTING
Replace Batt
PRESS THIS BUTTON TO RAISE THE TEMPERATURE SETTING
System
PRESS THIS BUTTON TO LOWER THE TEMPERATURE SETTING TEMPERATURE SETTING RANGE: HEAT: 40TO 90F (4.5T0 32C) COOL: 50TO 99F (10 T0 37C)
M22014
The first press of the Up or Down button turns on the backlight. The second press of the Up or Down button changes the temperature setting.
69-1722 8
Replace Batteries
1. When the Replace Battery indicator is flashing, replace batteries promptly with two fresh AAA alkaline batteries.
REPLACE BATTERY INDICATOR
System Cool
M22015
The thermostat does not lose any settings when the batteries are replaced; all settings are permanently stored in memory.
Replace Batteries (Cont)
2. 3. Press the battery holder latch to release the battery holder. Remove the battery holder from the thermostat.
BATTERY HOLDER LATCH BATTERY HOLDER
Fan Auto Cool
M22016
4. Remove the old batteries and insert two fresh AAA alkaline batteries as marked on the battery holder.
BATTERY HOLDER PUSH BATTERIES OUT THROUGH THIS HOLE
BATTERY DIRECTION
M22017
5. Insert battery holder as shown.
Review Battery Tips
1. Replace the batteries as soon as Replace Batt flashes in the display. The Replace Battery indicator flashes in the display two months before the batteries run down completely. Always use fresh AAA alkaline batteries. Non-alkaline batteries do not last as long and can leak, causing thermostat damage. Although the thermostat has a Replace Battery indicator, replace the batteries once a year to prevent the thermostat and heating/cooling system from shutting down due to lack of battery power.
NOTE: Replacing the batteries once a year also helps prevent battery leakage that can damage the thermostat. 4. As a precaution, replace the batteries when leaving your home for more than a month to prevent your heating/cooling system from shutting down if the batteries run down completely.
Built-in Compressor Protection
The RTH5100B Thermostat has built-in compressor protection (minimum-off timer) that prevents the compressor from restarting too early after a shutdown. The minimum-off timer is activated after the compressor turns off. If there is a call during the minimum-off timer, the thermostat flashes Cool On or Heat Ona in the display. When the minimum-off timer expires, Cool On or Heat Ona appears solidly in the display and the compressor and fan turn on.
________ a Heat Pumps only.
Accessory/Replacement Parts
1. Cover PlatesUsed to cover marks on the wall Part Number: 50001137-001 (Small) Cover Plate 50002883-001 (Large) Cover Plate To order, call Honeywell Customer Care at 1-800-468-1502.
M22185
Replacement Battery Holder Part Number 50000951-001 Battery Holder To order, call Honeywell Customer Care at 1-800-468-1502.
M22018
Troubleshooting Tips
If. Display is blank. Temperature settings do not change. Heating system does not turn on. Then. Check that fresh AAA alkaline batteries are installed as marked on the battery holder. Check that the temperature settings are: Heating 40F to 90F(4.5C to 32C). Cooling 50F to 99F (10C to 37C). Set the system to Heat by pressing the System button. Check the heat temperature setting to be sure it is set above the room temperature and Heat On shows solidly in the display. Check the circuit breaker to be sure it is not tripped. Check power switch at heating and/or cooling system to be sure it is on. Check the furnace door to be sure it is closed securely. Wait five minutes for the heating system to respond. If all of this was checked, contact your local heating and cooling contractor.
Troubleshooting Tips (Cont)
If. Cooling system does not turn on. Then. Set the system to Cool by pressing the System button. Check the cool temperature setting to be sure it is set below the room temperature and Cool On shows solidly in the display. Check the circuit breaker to be sure it is not tripped. Check the power switch at the heating and/or cooling system to be sure it is on. Check the furnace door to be sure it is closed securely. Wait five minutes for the cooling system to respond. If all of this was checked, contact your local heating and cooling contractor. Check Installer Setup Number 1, Heating and/or Cooling System Type; make sure the setting matches the installed heating and/or cooling system. Refer to Installation Instructions, 69-1716.
Cannot set System setting to Cool.
If. Heat On is not shown in the display. Then. Set the System setting to Heat and set the temperature setting above the room temperature. If Heat On is shown solidly in the display, but the heating system does not turn on, see Heating system does not turn on in theTroubleshooting Tips. Set the System setting to Cool and set the temperature setting below the room temperature. If Cool On is shown solidly in the display, but the cooling system does not turn on, see Cooling system does not turn on in the Troubleshooting Tips.
Cool On is not shown in the display.
Heat On is Compressor minimum-off timer is active. flashing in the Wait up to five minutes for the heating display (heat system to turn on. pumps only). Cool On is Compressor minimum-off timer is active. flashing in the Wait up to five minutes for the cooling display. system to turn on.
If. Fan does not turn on in a call for heat (electric furnaces only). Heat pump puts out cool air in the heat mode and warm air in the cool mode (heat pumps only). Both the heating and cooling systems are running at the same time. Then. Check Installer Setup Number 3, Fan Control in Heating, and make sure it is set to Electric Heat (Setting 1).Refer to Installation Instructions, 69-1716 Check Installer Setup Number 2, Heat Pump Changeover Valve, and make sure the setting matches the changeover required by the installed heat pump. Refer to Installation Instructions, 69-1716. Check Installer Setup Number 1, Heating and/or Cooling System Type, and make sure the setting matches the installed heating and/or cooling system. Refer to Installation Instructions, 69-1716. Check and make sure the bare portions of the wires are not touching.
If. Heating system is running in cool mode. Heating system does not turn off and the heat temperature setting is set below the room temperature (Heat On is not shown in the display). Then. Check Installer Setup Number 1, Heating and/or Cooling System Type, and make sure the setting matches the installed heating and/or cooling system. Refer to Installation Instructions, 69-1716. Check Installer Setup Number 1, Heating and/or Cooling System Type, and make sure the setting matches the installed heating and/or cooling system. Refer to Installation Instructions, 69-1716.
Customer Assistance
For assistance with your Honeywell product please visit www.honeywell.com/yourhome or call Honeywell Customer Care toll free at 1-800-468-1502. Before calling, please have the thermostat model number and date code available.
MODEL NUMBER
xxxxxxxx xxxxxx
DATE CODE
THERMOSTAT BATTERY HOLDER
M22178
Limited One Year Warranty
21 69-1722
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods Dock 4 MN10-Douglas Dr N Golden Valley, MN 55422 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywells sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
Limited One-Year Warranty (Cont)
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limite, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.
Automation and Control Solutions
Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422
Honeywell Limited-Honeywell Limite 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
69-1722 G.H. 5-04
www.honeywell.com/yourhome
Technical specifications
Full description
The Honeywell RTH5100B1025 digital non-programmable thermostat is designed to give you many years of reliable service. It features easy-to-use, push button climate control. The RTH5100B1025 non-programmable thermostat features settings that are permanently stored in memory and do not require battery power. Large, Clear Backlit Display The Honeywell RTH5100B1025 digital non-programmable thermostat comes with a large, clear, backlit display that is easy to read, even in the dark. Fast, Easy Battery Replacement The RTH5100B1025 non-programmable thermostat includes a removable battery holder for fast, easy replacement. Built-In Compressor Protection This digital thermostat helps prevent damage to the compressor in your air conditioning or heat pump system with built-in compressor protection. Auto Changeover The RTH5100B1025 features an auto changeover function that automatically selects heating or cooling depending on the indoor temperature.
Tags
DCR-TRV510E 20VL63 Speedstream 4100 RDR-HX650 KRC-177RA Samsung S760 FX-250HA Iphoto 6 Astrale GR-267EHF MEH-P9000R TCD-100 Track PRO W1941S-PF Satellite U400 UP102 Navman S90I NV-MX8EG 22LG30R System I V2 2 PM 2658 3 0 AWW1417 GK1635T GN 6110 Energyxt2 5 Deluxe VS-2480CD AW2126F Onyx 1220 KZ-42TS1E GT-S7070 RS277acpn XAA 15-20-30W SR2016 L226WT-BF URC-288 Rc8 VR5000 1031-V RX-V750 W200I PLC-SW20AR Smartphone Roland R-70 AX380 DRR-F100 RM-1000BP DV-363-K 2 Plus Nakamichi 550 Modena CD52 Synkron 300W NV-XYZ777LE FS-30-FS-20 Techwood MD65 KAC-921 GV-600 LN22B350f2 LAV72730-W RX-330 Virtual DJ Deluxe Manual Thermostat Vista-20PS SGH-T746 Clasic CJ-V74CL EL250 T703V Keypad Flexatx E15g1 PDP2840 KRC-158R NR100 Boost XL200 LM520 MR-16hdcd Sharp R8-A 90 -QD CDN22 Series SBH650 Express Hkts 8 755DF Center Barometer BQ-330 Autohelm 1000 DPR-1260 HCD-541 Harmony 659 GXP1200 HD2420 28DG21U P4P800s-X MG8 2FX MC250 1680 CT
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101

1. Honeywell RTH5100B 1025 Deluxe Manual Thermostat
2. Honeywell RTH5100B1025 Deluxe Manual Thermostat
3. Honeywell RTH111B Vertical Digital Manual Thermostat
4. Honeywell HHT 011 Compact Air Purifier with Permanent HEPA Filter
5. Honeywell 50250N 99.97 Pure HEPA Round Air Purifier