ACT ACT 10 Digital Keypad
|
|
Bookmark ACT ACT 10 Digital Keypad |
About ACT ACT 10 Digital KeypadHere you can find all about ACT ACT 10 Digital Keypad like manual and other informations. For example: review.
ACT ACT 10 Digital Keypad manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a ACT ACT 10 Digital Keypad please write about it to help other people. [ Report abuse or wrong photo | Share your ACT ACT 10 Digital Keypad photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)ACT ACT 10 Digital Keypad, size: 986 KB |
ACT ACT 10 Digital Keypad
User reviews and opinions
| djauniau |
12:33pm on Wednesday, November 3rd, 2010 ![]() |
| VERY PLEASED The p+p seemed quite a lot, but balanced with the low price for the item, made it a good price and the mouse is great- easy to use. | |
| wakka wakka |
12:47pm on Saturday, August 21st, 2010 ![]() |
| Sleek design, great price, ergonomic and adjustable, lots of control options No force feedback - but does that really matter? | |
| MuiFull |
2:00am on Tuesday, May 11th, 2010 ![]() |
| Its Pink, Lights up! Very smooth operation and comfortable. Have been able to use on a number of different surfaces None to think of | |
| Zwirni78 |
3:09pm on Thursday, April 15th, 2010 ![]() |
| [...]everything works as expected.[...]...........Thanks Easy To Install","Increases Speed","Reliable Performance Heavy | |
| reinhard |
1:39pm on Wednesday, March 10th, 2010 ![]() |
| Features * USB Plug and Play * Ergonomic design * 8 buttons * 2 base shift buttons * Throttle Lever * 8-way hat switch * 3-D Twist handle (rudder) * 4... | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents
ACT 10
Product Overview
The ACT 10 digital keypad is a sturdy and durable unit made from vandal resistant die cast zinc with backlit stainless steel keys. This multi-purpose keypad caters for access control, door monitoring and interlock applications.
Digital Keypad
Main Features
10 User codes 2 Output relays 2 doors, 2 user groups Interlock, fire alarm input, door monitoring Surface or Flush mount options Indoor or outdoor (IP54) Zinc diecast housing, stainless steel keys Front and back tamper Backlit keypad
Installation / Specification Guidelines
220/240 Volts AC
The ACT 10 requires an operating voltage of 12 to 24 volts AC or DC. For full functionality use 12 volts DC supply. 2 x 5 amp relay outputs The ACT 10 can be installed either indoors or outdoors (IP54) Operating Temperature: -10 to +50 C There are flush mounting and weather shield accessories available for this product
12/24 Volts AC/DC
3 Outputs (100mA)
Tamper
3 Inputs (100mA)
ACT 10 System Schematic
Product Specification
12/24 Volts AC/DC 40/120 mA 700 grams -10 to +50 C 138 x 87 x 37 mm Surface or Flush Indoor or Outdoor
ACT 10 Digital Keypad
Operating Voltage: Current Consumption: Weight: Operating Temperature: Dimensions (HxWxD): Mounting: Installation:
ACT 10 Flush Kit
ACT Standalone products comparison chart
Feature Doors Users User Groups Master Slave Operation Proximity Pin Pin & Prox Pin or Prox Keypad Backlighting Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp Yes 5 amp Yes 5 amp 2 Yes Yes Yes Yes Yes IP67 Yes IP67 Yes IP54 Yes Yes Yes IPYes Yes Yes IPYes Yes Yes IP67 Yes Yes Yes Yes Yes 5 amp 1 Yes ACT 10 ACT 5 Prox ACT 10 ACTsmart2 ACTsmart2 ACTsmartYes Yes 1 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 5 amp 1 Yes Yes Yes Yes Yes Yes 5 amp 1 Yes 1 Yes
Front Plate Dimensions (HxWxD): Back Box Dimensions (HxWxD): Weight:
185 x 130 x 3 mm
150 x 90 x 40 mm 750 grams
ACT 10 Weather Shield
Interlock Door Monitoring Fire Alarm Override Master Slave Operation Toggle Mode Door Relay Output Programmable Inputs Programmable Outputs Programmable Inputs/ Outputs Push to release button input Tamper Output 12-24volt DC or AC Input* IP Rating
Dimensions (HxWxD): Weight:
140 x 92 x 74 mm 475 grams
* ACTsmart2 units require a DC supply when programmable input / outputs or master slave operation are used.
Access Control Technology Unit C1, South City Business Park, Tallaght, Dublin 24, Ireland. t: 353 (0) 2570. f: 353 (0) 0427. e: sales@accesscontrol.ie. w: www.accesscontrol.ie

30 SECOND PROGRAMMING GUIDE (for typical system)
1. Enter Programming Mode.
Press X button followed by the programming code (9999) The yellow indicator should be flashing 2. Change User 1 code. Press 0, then 1 followed by the new user 1 code (four digits)
3. Change Programming Code.
Press 0, then % followed by the new programming code (four digits). 4. Set Desired Relay Active Time. Press 2, then 0. Allow the buzzer to sound for the desired period. Press % to stop this period is now programmed into the relay timer. 5. Exit Programming Mode. Press the X button. The yellow LED should stop flashing. The keypad is now ready for normal use. Note: The keypad may be returned to its factory default condition at any time by entering the programming mode and pressing the % three times. For information on programming the advanced features of the keypad, please refer to the complete programming guide on the other side of this sheet.
Unit 8, IDA Business Park, Whitestown, Dublin 24, Ireland. Tel: 353-1-4622585 Fax: 353-1-4622587 Copyright 1999 Access Control Technology Ltd. (18-00001-02) As with any access control system, always ensure that there is an alternate means of escape in the event of the unit failing to operate due to power loss or in the event of fire. Dont forget to change the programming code to something known only to yourself. Never use the onboard relay to switch AC mains voltage. An external relay isolated electrically from the ACT10 should be used for this purpose. Always remember to place the supplied Varistor across the terminals of the door strike coil to protect the relay contacts. Always remember to factory default the controller before you start programming.
For full details on the ACT product range and a list of distributors, Visit our website www.accesscontrol.ie
INSTALLATION NOTES
IMPORTANT
ACT10 DIGITAL KEYPAD
KEYPAD OPTIONS
30. Door Chime When set, whenever the door contact is opened, the built-in buzzer makes a chime sound and the buzzer output activates for 2 seconds. 31. Silent Operation When set, the keypad operates silently, that is no audible tones (keypresses or confirm tones) are produced from the built-in buzzer. 32. Permanent Backlighting When set (default), the keypad illumination is always on. This option will override option 42 (Auto backlighting) 33. Locksaver (Anti tailgating) When set, and when the relay is active (following a valid code or button release), the relay timer is truncated to 2 seconds when the door contact opens. This ensures that irrespective of programmed relay time, the door will be locked as soon as it closes, and any person following will have to enter a code. 34. Alarm Keypad Operation When set, the keypad may be used as a remote keypad for an alarm system. The red and green indicators are controlled by the door contact and the release button inputs respectively, and the built in buzzer is controlled by the interlock input. 35. Interlock When set, two or more keypads may be interlocked so that only one controlled door may be open at any one time. The interlock output is active whenever the relay is active or when the door contact is open. When the interlock input is active the release button and all codes are inactive, and the red indicator flashes. The interlock outputs and inputs of any number of keypads may be combined on a single wire. 36. Six Digit Codes When set, all user codes and the programming codes are six digits long. The default user one code becomes 123456 and the default programmer code becomes 999999. 37. Twin Codes When set, two different codes must be entered within 15 seconds in order to open the door. The outputs activated are those which have been programmed for the first code to be entered. 40. Door Forced Alarm When set, the buzzer output is activated if the door contact opens when a valid code has not been entered. The output is deactivated when a valid code is next entered. This is useful for monitoring fire doors etc. 41. Group Disable When set, the top five user codes (5-9) are inactive any time the interlock input is activated. This restricts access to certain codes under external control (i.e. an alarm system output or a time clock). 42. Auto Backlighting When set, the keypad illumination is normally off, but will switch on in response to any key being pressed or while in programming mode. This option is overridden by option 32 (permanent backilghting). To prevent any illumination, unset options 32 and 42. 43. Door Ajar Alarm When set, and the door contact has been open for longer than the time programmed into the door ajar timer, the builtin and external buzzers sound intermittently. The buzzers may be silenced by closing the door and entering a valid code. 44. Guest Button When set, (default) and when the # key on the keypad is pressed, the buzzer output is activated for the duration programmed in the guest buzzer timer. 45. Fire Alarm Override When set, the relay is held active whenever the interlock input is active, and the green indicator will flash. This is useful for following a fire alarm system to override controlled doors. 46. Release Button for Second door When set, The keypad activates the door 2 relay which follows output 2s timer, this allows two doors to be controlled using one keypad. 47. Duress Codes When set, and when a duress code is entered, the door is opened normally and output 2 is activated. A duress code is any valid user code with one added to the last digit. The output will be reset when a valid user code is entered. When the duress option is set, user codes which have 9 as the last digit should be avoided as there is no corresponding duress code. Incorrect Code Lockout When three invalid codes have been entered in a row. The keypad will enter lockout mode for 20 seconds. During this time, the red indicator will flash and all user coded will be inactive.
ACT10 Digital Keypad Programming
To enter programming mode:
Press the X button followed by the engineering code (initially all 9999) The Yellow LED will flash while in programming mode. If X is pressed at any time or no key is pressed within 30 seconds, programming mode is exited.
Changing Codes:
(from programming mode) Enter 0 (Change codes) 0-9, % (user number 0-9, % = programming code) 000000-999999 (4 or 6 digit code 000000 deletes user) Default user codes : Programming = 9999(99), User 1 =1234(56), All others inactive.
Setting switched output combinations:
(From programming mode) Enter 1 (Set Outputs) 0-9 (User number 0-9) 0-7 (Output function code) Function Code Door Output Output 2 Output Toggled 1 Timed 2 Timed 3 Timed Timed 4 Timed 5 Timed Timed 6 Timed Timed 7 Timed Timed Timed Default function code is 1 (Relay Timed) for all users. When the door is toggled open, this will be indicated by the green indicator flashing.
Setting timers:
(From programming mode) Ente r 2 (Set Timers 0-4 (Timer number) {Buzzer sounds indicating timing wait required period} % (Stop timing) {Buzzer stops timer set} Timer No.
Function
Relay time Output 2 time Output 3 time Door Ajar time Guest Buzzer time
Default
5s 5s 5s 30s 2s
Timers may be set to any duration between 2 seconds and 4 minutes.
Setting Configuration:
(From programming mode) Enter 30-37 or 40-47 0-1 Option No.
(Option number) (1= Set, 0 = Unset) Function
Door Chime Silent Operation Permanent Backlighting
Off Off Off
Locksaver (Anti Tailgating) Off Alarm Keypad Operation Off Interlock Six Digit Codes Twin Codes Door Forced Alarm Group Disable Auto backlighting Door Ajar Alarm Guest Button Fire Alarm Override Second Door Release Duress Codes Off Off Off Off Off Off Off On Off Off Off
Restoring Factory Defaults
(From Programming Mode) % % % (Factory Defaults Restored & Keypad exits programming mode) If the programming code has been forgotten. 1. Remove link LK1. 2. Apply power to unit. 3. Replace link LK1. 4. Remove power. 5. Restore power and proceed with programming. Note: The keypad will not operate correctly without LK1 in place.
Typical ACT10 Configuration
(Normally de-energised lock shown)
Power up without link if Progr amming code has been lost.
12-24 AC/DC
Power Supply 12-24V ACDC
Door Release Button
+ N/C C N/O
OMR ON 5A 0A C V 5 A V DC
OMR ON 0 V A C A 0 V DC A
Door Contact
0V Interlock (PB2) Push Button Door Contact
OUTPUTS
INPUTS
0V Buzzer OP3 Duress OP2 Interlock
TAMPER
Batch: 20xx-1 Product:ACT10 Rev3.0 Serial No. 12345
Important ! Always Place Varistor Across All Lock Terminals +V
Guest Buzzer
0123456789
N/C C N/O
Volt - Free Tamper Contacts
Door Release Button for Door 2
This diagram shows revision (3.1) of the ACT10 This unit may be used to control 2 doors as illustrated in the diagram above. Connections and programming for this unit are exactly the same as for previous versions, however the connector positions have changed as shown in the above diagram.
Unit 8 IDA Business Park, Whitestown, Tallaght, Dublin 24, Ireland. Telephone: 462 2585. Telefax: 462 2587. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie
RELAY DOOR 2
Door 2
ACT 10 Digital Keypad Guides to outdoor installation in exposed areas.
Access denied Standby
Access Granted
Do not apply silicone to the bottom of the keypad as this will block the air vents and trap any water which may enter the keypad. If a weather cowl is fitted the same applies. Do install a weather cowl when the keypad is installed on an uneven surface or if in a very exposed area. Do apply silicone to the top and two sides of the keypad or cowl, when used. Do silicone all screw mounting positions and cable entry.
Tags
TX-P37x10B DS18DL Iden I875 Nokia N8 M1917A-BZ 47LG5500 P2470LHD Elite Hdspmadi UX-MF70 DC400 C 13 SPF-75H Samsung S73 NAD M4 SGH-A800 3M X90W Efah16W Mobile CB 60800W MHC-3500 32PW9551 12 F50 FD Midland G227 Philips 105E Wolf PBT A8R-mvpi CA-55 LDS4821WW Servers Nibiru Siemens M50 DAC8007EE VGN-SR21m S TF-DVD500 MSF615X Sunbeam 3280 DP-2010E Srfhm22 Captureview 8X22 Fantom G7 Triggerfinger Wisl 10 Acer P600 Pavilion T800 HS-55W WMS 400 VGP-MR100U Viewfinder PM90 SAT M2 ST-GT650 Livephone TU73 RP603Z SA-DT100 Imax B6 9-5 2000 DRC-400 Fallout 110-5501 TOP CBL 160 Preamp B3210 TL110 DSC-W180 R CX7330 Dcu-11 WXZ466MP MP130 P6250 WF9702N3W NEC VT46 LST180H-2 DZ-MV780E Cygnus125-2000 Workstation CDX-4000RX DPL913VD CS-8060 GR-462CSF DSC-W180 AV220G DR175B A-Z370 Dvdr3480-05 Pro-G AVR 435 CFD-RG880CP ME747AK-SI 959NF ALL-IN-ONE 42LG60FD KDL-32S2020 DPX-5010 Xxx 7 KRF-X9080D DVD634 001 Review Synergy 1 CZ-21A083N X-560WP PRO 451
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101