Reviews & Opinions
Independent and trusted. Read before buy ACT DS100E!

ACT DS100E


Bookmark
ACT DS100E

Bookmark and Share

 

About ACT DS100E
Here you can find all about ACT DS100E like manual and other informations. For example: review.

ACT DS100E manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a ACT DS100E please write about it to help other people.
[ Report abuse or wrong photo | Share your ACT DS100E photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page 

Download (English)
ACT DS100E - Installation Diagram, size: 451 KB
Related manuals
ACT DS100E Door Station Installation

 

ACT DS100E

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

DS100e Door Station Installation

ACT 2000

Important ! Always Place Varistor Across Lock Terminals
OP2 = Aux Relay OP3 = OP3 OP4 = OP2 IP1 = Aux Input IP2 = Door Contact IP3 = Push Button

Door Contact

NETWORK

Door Release Button

Network cable is single shielded twisted pair, Belden 9501 or similar To next door

A B 0V

A B Shield

OP3 OP4 0V IP1 IP2 IP3

DTR RX TX 0V B

SERIAL NETWORK

Total Length max 1.4km
Wiring for Clock and Data / Wiegand Reader White Green Blue Red Black Brown Yellow Orange SENSE CLOCK / DATA 1 DATA / DATA 0 +5v 0v RED GREEN (Buzzer Ctrl)

OP1 OP2

C NO NC C

5A 250VAC 5A 30VDC

TAMPER

Entry Reader

Power Supply Unit

+12V 0V

MAINS PRESENT 12V DC

ADDRESS

Entry/Exit Reader
Note: If the Mains Present or Door Contact inputs are not used, they should be linked to 0V

Max len 30M

Cable: 8 Core Screened Belden 9504 or equiv
03 OFF OFF OFF ON 04 OFF OFF ON 05 OFF OFF ON 06 OFF OFF ON 07 OFF OFF ON 08 OFF ON 09 OFF ON
10 OFF ON 11 OFF ON 12 OFF ON 13 OFF ON 14 OFF ON 15 OFF ON 16 ON
OFF ON OFF ON ON ON ON ON

OFF ON

OFF OFF OFF ON ON ON OFF ON
For Clock & Data Readers, wire exit reader in parallel but leave it's sense line unconnected. For Wiegand Readers, wire the DATA 0 of the exit reader to SENSE on the DS100e
This illustration shows wiring On for a normally energised To set the door number, set address switches lock. If a normally de-energised 4-8 as shown lock is required, use the N/O relay contacts. LED Functionality:
Red LED indicates the status of communications with the Controller. While online to the controller the Red LED will flash rapidly. If there is a problem it will flash slowly (about once a second). Green LED will flash if an event occurs on the DS100e.

Required Address

OFF OFF OFF OFF OFF ON

OFF OFF OFF OFF

FACTORY DEFAULT This unit should be reset to its factory default condition before installation. To do this, power the unit up with ALL switches in the OFF position. The two LED's will illuminate for about 2 sec. The correct switch settings may then be set.

www.accesscontrol.ie

18-00037

doc1

Card Access Systems

Simple to install user friendly door access controllers and card readers with optional PC software for system administration. Superb features include Access Control, Time & Attendance, Door Alarm Monitoring, Remote Site Dial Up, and Fire Alarm Override.
When performance counts ACT Card Access Systems
ACT: Totally committed to customer satisfaction

Card Access

Systems
Product Overview The ACT1000 single door controller offers the ideal upgrade path from the ACT standalone product range. For systems above one door choose the ACT2000 or ACT3000 door controllers. To extend the controllers from two up to sixteen doors install the DS100 single door expander. For larger systems up to one thousand doors simply network the ACT 2000 or ACT3000 controllers to a PC. ACT door controllers are compatible with the full range of ACT card readers and most third party readers. Choose from the ACTWinPro and Pro Lite PC applications to exploit the full potential of hardware controllers. Applications Access Control: Prevent unauthorised access to areas by staff visitors or strangers. Provide secure and speedy access to secured areas for authorised personnel. Record all card and door transactions by time and date in the powerful ACTWinPro database. Add and delete cardholders in seconds. Control and administrate remote sites via ACTWinPro software. Time & Attendance: Install entry and exit readers on perimeter doors and record staff time and attendance. Export information to industry standard pay roll software packages. Door Alarm Monitoring, Building Evacuation and Door Control: Monitor the status of all doors and alert staff or security personnel of any unauthorised access. In the event of fire automatically release all doors and provide a roll call of all staff and visitors. Provide fast and effective door control from a single point.
ACT2000 direct connect to PC ACT1000

Features

Feature Doors Cardholders Log Events User Groups Time zones Timed Actions Printer Facility Interlock Roll Call Multi client Full admin audit trail Anti-Pass back Timed anti-passback Holiday Scheduler Entry Exit Facility Fire Alarm Override Pin & Card Flash upgradeable Built in TCP/IP ACT10,Y Y Y NA NA N N Y Y Y Y N N ACTto 16 * 20,000 5,32 Y Y Y NA NA Y N Y Y Y Y N N ACTto 16 * 30,000 5,256 Y Y Y NA NA Y Y Y Y Y Y Y Y ACTWin Pro ACTWin Pro Lite 30,000 30,000 Infinite Infinite Infinite Infinite Infinite Infinite Y Y Y Y NA NA Y Y Y N Y (5) N NA NA NA NA Y Y NA NA NA NA NA NA NA NA NA NA
*The DS100 is a single door expander for the ACT2000/3000 controllers (max 14 per controller).
Controller Electrical & Mechanical Specification
Operating Voltage (DC) Current Consumption Weight Operating Temperature Dimensions (WxHxD in mm) * ACT1000 ACT2000/- 14.5 volts 10 - 14.5 volts 40 - 150 mA 120 to 230 mA 200 to 420 mA 0.75 kilos.7 kilos -100 to 500C -100 to 500C 87x138x37 270x190x60 DS- 14.5 volts 40 to 120 mA 0.414 kilos -100 to 500C 110x190x60
* These units must be installed indoors or in a weather sealed and heated outdoor housing
Card Reader Electrical & Mechanical Specification
Operating Voltage (DC) Current Consumption Weight Dimensions (WxHxD in mm) Surface Flush Indoor/Outdoor *ACTPro including 1040/50/60 ACT- 12 volts 20 mA 0.5 kilos 44x138x37 Y ACTPro- 12 volts 40 mA 0.2 kilos 36x108x13 Y ACTPro* 5 - 12 volts 40 mA 0.2 kilos 100x110x35 100x110x20 Y

Cabling Specification

From ACT1000/2000/3000 ACT1000/2000/DS100

16 Doors Max

To PC (Direct connect) Card Readers DS100 (last) PC Interface PC Lock, Push Button etc
ACT2000/3000 ACT1000/2000 PC Interface ACT1000/2000/DS100
Max Cable Run 30m 30m at 5 volts 100m at 12 volts 1.4km 1.4km 10m
Cable Twisted Screen Pair 8 Core Screened Twisted Screen Pair Twisted Screen Pair Twisted Screen Pair Standard Alarm Cable
Note: For systems above 16 doors, install ACT PC Interface. 1000 Doors Max
When networking Controllers to the interface or the DS100 to the ACT2000 the maximum distance to the last unit is 1.4km. The units must be daisy chained and not star wired. Category 5 or Belden cable maybe used
PC Specification: ACTWin software requires Windows 9X or Windows NT - XP.

ACT Cards and Fobs

ACT WinPro

ACT Pro 1050/1060

ACT Pro 1040 ACT Pro 1030

ACT 1000

ACT 1010

ACT 2000/3000

Unit C1, South City Business Park, Tallaght, Dublin 24. Telephone: 466 2570. Telefax: 452 0427. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ie

 

Tags

SA3025 H4D40 LA32B550 Arxl 145 DC T800 WD-14313RD DG632 37PFL5522D KX-FLM662CX Beocenter 2200 Radio 1700-200 Citroen AX Splash Premio Twin RX-V795RDS T56840 RS21klal AR-507 TA-AX301 Review Motorazr-V9M CD1401B 53 KRF-V8010D 20U83B 50PX4R P910I Mcem1B RO102 700R-2007 UX-G68 KD-NX901 Descriptif Suite X5 DSC-W370 R 13 0 225-01 CLS45I Logicom CUT1 Pspad Sofa BED FC9222 OT-V570 HT-286 S-F50 FC6844 01 CF-21D10B CXT450 AH-D7000 YP-K5JAB Suunto D9 Usb-P3K Navisworks 2010 DV-S939 V2-P5v900 PWS 720 Dtxtreme Acuris S 21AA3356-21B Freestar 3 5 ICN 530 PRO 100 LE40N71B VGN-FW CR-325UKD RQ-SX35 HMD-A200 KX-TEM824 Holder HT-CT350 Dmcfs42 A105-S4014 Futaba 7CAP FLS873C VP-D250I WII Cuisine 5200 Okifax 160 Navigator MZ-R501PC SB5100 1250 FAX RHT-G550 PL-42P5HD ARX4570 AG-6024 Motorola V150 Stylus 1200 NV-GX7K NN-CT878 Neobio 40 CDX-CA600X 3500 DX Hdmi Plus AM1480 Siemens AX75 SE-80PCI DXZ758RMC AV-28KT1SUF IV F

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101