Ademco 4111XM/First Alert FA-150C Program Sheet
Enter Program Move to Location View Location Exit Program Hex Program *20 Installer Code *21 Quick Arm Enable *22 RF System Type 4111 + 8 + 0 + 0 (Display should show 20) or Power down then back up and press * and # within 1 minute * + Location # + Location (Display will read off one digit at a time) 1. *98 OR 2. *99 if needing to re-enter programming later by Code + 8 + 00 Hex A = # + 10 B = # + 11 C = # + 12 D = # + 13 E = # + 14 F = # + 15
I _4 _I _1 _I _1 _I _1 _I I _1 _I I _? _I 0 = No 1 = Yes 0 = None 1 = 5700 (4281) Receiver 2 = 5800 (5881) Receiver
*23 Force Bypass Enable
I _0 _I
0 = No 1 = Yes
*25 Output Relay Module *28 Single Alarm Sounding/Zone *29 Fire Sounder Timeout *30 Alarm Bell Timeout
I _0 _I I _0 _I I _1 _I I _2 _I
0 = None 3 = 4204 Relay Module
*38 Entry Delay Exit Delay = Entry + 15 seconds
I _2 _I
*39 Zone 3 Response to Open *40 PABX Access Code
*41 Primary Phone (12 digits) End Phone Number with * *42 Secondary Phone
I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ # + 11 = * # + 12 = # # + 13 = 2.5 second pause I_ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _ _I _
_I _ _I
0 = No 1 = Yes 0 = 400ms 1 = 10ms _I _ _I _ _I
0 = Yes 1 = No Fire Timeout 0 = None 1 = 4 minutes 2 = 8 minutes 3 = 12 minutes 4 = 16minutes 1 = 20 seconds 2 = 30 seconds 3 = 45 seconds 4 = 60 seconds 5 = 90 seconds
(If 9 is needed to dial add here) _I _ _I _ _I _ _I _ _I _I
*43 Partition 1 Account (Hex A = # + 10 *43 Partition 1 Account
B = # + 11
I _ _I _ _I _ _I _ _I C = # + 12 D = # + 13 E = # + 14 I_ _I _
*45 Phone System Select
I _1 _I
*46 Report Format
0 = Pulse Dialing 1 = DTMF Dialing 2 = Pulse Dialing, CS on Watts Line 3 = DTMF Dialing, CS on Watts Line 0 = 3/1, 4/1 Ademco L/S Standard 1 = 3/1, 4/1 Radionics Standard 2 = 4/2 Ademco L/S Standard 3 = 4/2 Radionics Standard 6 = 4/2 Ademco Express 7 = Contact ID 8 = 3/1, 4/1 Ademco L/S Expanded 9 = 3/1, 4/1 Radionics Expanded
I _7 _I
Created by Mark Leuck 01/20/2002
F = # + 15
*24 RF House Code I _0 _I _0 _I 00 = Disabled, 01-31 If using old 5700 series wireless this must match sensor dip switches Also used with 5804BD keyfobs and 5827BD Keypads
5700 Sensors are added as hardwire zones 10 to 18 4281L receiver adds 4 zones, 4281M and 4281H add 8 zones
*47 Split/Dual Reporting I _0 _I To Secondary Phone Backup only All Other Reports Open/Close, Test All Reports All Reports All Reports 0 = No 1 = Yes 0 = None 1 = 24 Hours 2 = Weekly 3 = Monthly 0 = No 1 = Yes
To Primary Phone 0 = All Reports 1 = Alarms, Restore, Cancel 2 = All Reports except Open/Close, Test 3 = Alarms, Restore, Cancel 4 = All Reports except Open/Close, Test 5 = All Reports (Dual Reporting) *Sec Burg Dial Delay *49 Periodic Test Message I _0 _I I _3 _I
*50 Sescoa/Radionics *51 Confirmation of Arming Ding
I _0 _I I _0 _I
*52 Zone 3 Response
0 = 400 ms 1 = 10 ms
Must use 6139 Alpha Keypad here
*56 Zone Assignments 1. Enter Zone to program (01 to 96) Hardwire 4219/4229 Expander Police Panic Duress Receiver Trouble Wireless Fire Panic Medical Panic 2. This shows current summary of Zone programming
Zones 01 to 08 Zones 10 to 17 Zone 07 Zone 08 Zone 09 Zones 10 to 39 Zone 95 Zone 96
(* for next, # for previous menu)
3. Enter Zone Type
(* for next, # for previous menu) 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay (RF only) 21 = Arm-Away (RF only) 22 = Disarm (RF only) 23 = No Alarm Response
4. Program Partition of Zone
00 = Zone Disabled 01 = Delay Zone 02 = Do not Use 03 = Perimeter/Instant 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic
(* for next, # for previous menu) 1 = Partition = Partition 2 Top Right Button = Loop 2 Top Left Button = Loop 3 Bottom Left Button = Loop 4 (* for next, # for previous menu) (10 in first section gives a report of A0)
(Each button counts as 1 zone)
5. Enter Report Code
Hardwire Zones will advance to step 9, for Wireless Zones continue (If it doesn't go to next steps check if Receiver has been programmed in *22)
0 = No 1 = Yes 2 = Yes for RF Arming (Keyfobs)
(Depends on receiver capacity)
6. Enter type of Sensor 2 = Auxiliary Wired Sensor (if 4219/4229 Zone Expander) 3 for Supervised RF (most sensors are RF) 4 for Un-Supervised RF 5 RF Button Type (Keyfobs/Panics etc) 7. Enter Loop number (Some older systems show this) Door Switch Glassbreak Smoke Detectors Motions Keyfobs (Each button = 1 zone) (* for next, # for previous menu) Internal switch Loop 2, external sensor Loop 1 Loop 1 Loop 1 Loop 1 Loop 1 Bottom Right Button Loop 2 Top Right Button Loop 3 Top Left Button Loop 4 Bottom Left Button
8. Serial Number Programming
Press 1 and enter serial number st or trip sensor twice, 1 time to learn, 2nd to confirm Note: Serial number found on sticker on of sensor
This shows ready to learn
This shows Serial Number either manually entered or learned
This shows sensor was confirmed by activating twice 9. This is the new programming of sensor (* for next, # for previous menu)
10. Normally press 0 to return to start or 1 if if customer has 6139 keypad
*60 Trouble Report Code *61 Bypass Report Code *62 AC Loss Report Code *63 Low Bat Report Code *64 Test Report Code
I _1 _I _0 _I I _0 _I _0 _I I _1 _I _0 _I I _1 _I _0 _I
*65 Open Report Code Per Partition
*66 Close Report Code Per Partition *67 RF Xmtr Low Bat
*68 Cancel Report Code
*69 Group Restores for Trouble *70 Alarm Restore Code
*72 Bypass Restore Code *73 AC Restore Code
*71 Trouble Restore Code
*74 Low Bat Rest Code *75 RF Low Bat Rest Code *80 Output Device Programming *81 Zone Lists for Output Devices
I _0 _I _0 _I I _0 _I Partition 1 I _0 _I Partition 2
I _0 _I Partition 1 I _0 _I Partition 2 I _0 _I _0 _I I _1 _I _0 _I I _0 _I _0 _I I _0 _I I _0 _I _0 _I I _0 _I _0 _I I _0 _I _0 _I I _0 _I _0 _I I _0 _I _0 _I
*82 Custom Alpha Editing *83 Sequential Mode *94 Download Phone Number *95 Ring Count *96 Reinitialize Download *97 Default Panel *98 Exits Program Mode *99 Exits Program Mode (Do not Program) (Alternate way of programming sensors, not used) I _1 _I _ 8 _I _0 _I _ 0 _I _6 _I _ 8 _I _2 _I _ 1 _I _6 _I _ 9 _I _0 _I _ _I I _# 15 _I 0 to #15 #15 = Answer Machine
(No Value needed, keypad will just beep) (No Value needed, keypad will beep and default panel)
(Will allow re-entry with Code + 8 + 0 + 0)
Output Programming
*80 Output Device Programming (If 4204 Relay/4219/4229 Relay Zone Expander is used)
1. Enter Device to program (01 to 04)
(* for next, 00 to exit)
2. This shows summary of current Relay START programming (What starts the Relay) 3. This shows summary of current Relay STOP programming (What stops the Relay) 4. Enter what Relay will do when activated
5. Enter what will start the Relay (optional)
0 = No Response (or skip) 1 = Close for 2 seconds 2 = Close and stay closed 3 = Continuous Pulse On/Off
7. Enter Zone Type that will START the Relay (optional) 00 = Not Used (or skip) 01 = Entry/Exit Zone 03 = Perimeter/Instant Zone 04 = Interior Follower/Motions 05 = Trouble by Day/Alarm by Night 06 = 24 hour Silent/Holdup 07 = 24 hour Police Panic 08 = 24 hour Aux/Medical 09 = Fire 10 = Interior Delay 20 = Arm-Stay 21 = Arm-Away 22 = Disarming
6. Enter Zone List from *81 which STARTS Relay (optional) 0 = Not Used (or skip) 1 = Zone List = Zone List = Zone List 3
0 = Not Used (or skip) 1 = on an Alarm 2 = on a Zone Fault (or Keyfob button) 3 = on a Trouble (* for next, # for previous menu)
8. Enter which Partition will START this Device (Optional) 0 = Any Partition
(* for next, # for previous menu) 31 = End of Exit Time 32 = Start of Entry Time 33 = Any Burglar Alarm 34 = Code + # + 7 Key Entry 35 = Code + # + 8 Key Entry 36 = Bell Timeout or Disarm 37 = 2x Bell Timeout or Disarm 38 = Chime 39 = Any Fire Alarm 40 = Bypassing 41 = AC Power Failure 42 = System Low Battery (* for next, # for previous menu)
(Will not allow re-entry with Installer Code + 8 + 0 + 0)
1 = Partition = Partition 2 8. Enter Zone List that will STOP the Relay (optional) 0 = Not Used/Skip 1 = Zone List = Zone List = Zone List 3 (for Chime by Zone Feature) (* for next, # for previous menu)
8. Enter which Partition will STOP this Device (Optional) 0 = Any Partition 1 = Partition = Partition 2 10. This shows summary of new Relay START programming
11. This shows summary of new Relay STOP programming
12. Enter next Relay/Device to program or 00 to exit
*81 Zone Lists for Output Devices 1. Enter Zone List to program (01 to 03) or 00 to Quit
2. Enter Zone Number to add to List (01, 02 etc) or 00 to Quit Multiple Zones can be added (example: 01* 03* 25*etc) 3. If deleting a Zone List enter (01 to 03) or 0 to skip
4. If deleting Zone within Zone List enter 1 or 0 to skip
5. Enter next Zone List to program or 00 to Quit
4a. If 1 was entered from previous step enter here then 00 Multiple Zones can be deleted (example: 01* 03* 25*etc)
(* for next, # for previous menu) (* for next, # for previous menu) (* for next, # for previous menu) (* for next, # for previous menu) (* for next, # for previous menu) (* for next, # for previous menu)
9. Enter Zone Type that will STOP the Relay (optional)
Monitronics
Monitoring and Service: 1-800-447-9239
Ademco 4111XM/First Alert FA-150C Quick Reference Guide
Arm Away
User Code + AWAY key (2), the ARM light will turn on and the display will show AWAY Note: If system shows NOT READY press to view open zones
Arm Stay
Disarming / Silencing Alarms
User Code + STAY key (3), the ARM light will turn on and the display will show STAY
User Code + OFF key (1) If turning off an alarm enter 4 digit code + OFF key (1) again to clear display
Instant Doors
User Code + INSTANT (7) to arm system Entry/Exit doors will arm instant and motion detectors will be bypassed (display will show both STAY and INSTANT)
Zone Bypassing
User Code + BYPASS key (6) + zone (01, 02, 03 etc). The display will show BYPASS and the zone bypassed Note: Fire/Smoke Detector Zones cannot be bypassed
Enter MASTER CODE + CODE key (8) Enter User to program (3 to 4) Enter new 4-digit User Code
(Keypad will beep if command is successful)
User Codes
To delete a code Enter MASTER CODE + CODE key (8) Enter User to delete (3 to 4) then wait 3 seconds
on itr on
Master Code can only be changed by a Service Tech or by remote downloading
Door Chimes
Master Code + CHIME (9), if activated the display will show CHIME, repeat to turn Chimes OFF
Trouble Display
NO AC = Loss of AC power to the system LOW BAT = Main panel has a low battery, if LOW BAT appears with a zone number that zone has low battery CHECK = There is a problem with a wireless zone, fire zone or the main systems wireless receiver
Panic Buttons
By holding down a combination of numbers will activate the Police, Fire and Medical Panics Press and # at same time for Police Panic Press 1 and at the same time for Fire Panic Press 3 and # at the same time for Medical Panic Note: The Fire and Medical Panics may be reversed or disabled on some systems
Do not pause more than 2 seconds between each keypress or system will ignore above commands
Tags
DDX6029 TL-SC3130 119203C Models Text ICN Cinema 4 CCD-TRV16E DNX7260BT Xtreme 2 WS-7016U ICF-CD855V SR6400 SGH-T939 Sony HX5V M183DN MC1761EM Mouse Olympus OM10 RT-29FA34RB KDC-PS9070R 200FX Mkii ICF-C773L Navidrive ES-2024 ST-SE300 A G Presenter 7 Printer LD 87 Samsung 73V 67800 MHC-RXD10AV GT-E1117 NMX4000 Concept 470 CT-F850 Expedition-2006 SV-SD50 Guzzi V35 Motorola K1 SX230-2004 Mixer K5SS SR-L250i-B CQ-RD825 Digitech RP70 RM-VL1400T Review LA32A550p1F GR-DF420EK Zxlcd DRX6575Z KDC-MP535U 40A656a1F Lexmark E340 FM37 4G KV-14DA1 LAC6700R VGP-BPS5A KD-DV5000 Notebook 100 C525BEE 932BW SD-6G 15LC1RB Locator Ocirc LE VRX935VD Clipper ADZ628R T-levo N21 Witl 125 1 0 Silver HT303SUW TCE7224 PV-L453 BC-TRP CFD-S550L ETR-10N DXZ765MP QT3089K Samsung ES67 AL-350 TXP42S10E Glofiish X600 VD-4220 DR400 CMT-CP100 42FD9935-17 29PT8508 12 XR-6600RDS C2800 LST244T-2 TH-37PA60E 20HF5474-10 GT-E1360B CPA-9C TX12694TA LV2787 120 GPS IM7BLK
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101