Reviews & Opinions
Independent and trusted. Read before buy Ademco Vista-15psia!

Ademco Vista-15psia

 

 

Ademco Vista-15psiaAbout Ademco Vista-15psia
Here you can find all about Ademco Vista-15psia like manual and other informations. For example: review.

Ademco Vista-15psia manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Ademco Vista-15psia please write about it to help other people.
[ Report abuse or wrong photo | Share your Ademco Vista-15psia photo ]

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Ademco Vista-15psia - Programming Guide, size: 382 KB

Ademco Vista-15psia

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

ADEMCO VISTA-15PSIA

Control Panel
The versatile VISTA-15PSIA is the ideal choice for any residential installation. Hardwired expansion, graphic keypad support, two-wire smoke, detectors, scheduling options, certified to meet the ANSI/SIA-Standard for false alarm reduction, and a host of end-user and installer features separate the VISTA-15PSIA from all other six-zone panels offering you and your customers the most panel for the dollar.

FEATURES

Six on-board hardwired zones 16 hardwired expansion zones totalling wireless expansion zones Supports 6270 and 8132 graphic touchscreen keypads Eight independent keyfob zones allow wireless keys to be programmed without using any of the 26 zones Eight output devices Relays (Model 4204 Relay Modules, or 4229 Expansion Module), and/or X-10 devices (when used with a 1361X10 Transformer) Two low current on-board trigger outputs 50 Event Log viewable at system keypads with time/date stamp 32 system user codes Two installer configurable zone types allows the installer to "create custom zone types" by assigning all zone attributes Multiple actions on output devices depending on system "state" Turns light off when system arms Turns same lights on when system disarms Flashes same lights when system is in alarm Built-in phone line cut monitor with programmable delay and annunciation options Display on system keypads Trigger local sounders Trigger system bell Supports four-wire, and up to 16 two-wire smokes Works with Sentrol CleanMe maintenance signal Valuable End-User Features Viewable on system keypads: Exit countdown Time and date display* Event log* Auto keypad backlighting on entry Keyswitch arming Programmable macro buttons and single-button arming A variety of wireless remote controls for single-button operation User Scheduling Automatically activates X-10 and relays at programmed times Latchkey reports to pagers Auto arm/disarm "User access" time windows Supports up to two numeric pagers VIP Module allows system control from any touchtone phone Chime by zone ANSI/SIA-CP-01-2000 Standard for false alarm reduction Security Dealer Features Certified for SIA false alarm prevention specification for ANSI/SIA CP-01-2000 Automatic System Load Shed During extended AC power fail, the system battery will be disconnected to prevent irreversible battery failure. Reduces service calls to replace batteries Dynamic Signaling Reduces redundant reporting to the central station when multiple reporting methods are used; i.e. digital dialer and AlarmNet Radio
*Requires custom alpha keypad

SPECIFICATIONS

Electrical Aux. power 12VDC, 600mA maximum Seven hour standby at 400mA aux. load with four amp hour battery 16.5VAC/25VA transformer Alarm output 12VDC, 2.0 amps maximum For UL installations, combined aux. and alarm output cannot exceed 700mA Output Control Supports a maximum of eight output devices (combination of relays and/or X-10) plus two onboard triggers Zones Six hardwired zones Selectable response: 10msec, 350msec, 750msec 16 selectable zone types plus two configurable zone types Programmable swinger suppression Expansion Devices 4219 Eight hardwired zones 16mA 4204 Up to four relays 15mA standby (each active relay draws an additional 40mA) 4229 Eight hardwired zones and two relays 36mA (each active relay draws an additional 40mA) Accessories 4286 VIP Voice Module 220mA 5881ENL RF supports up to eight zones 60mA 5881ENM supports up to 16 zones 50mA 5881ENH supports up to 26 zones 50mA 5883 Transceiver supports up to 26 zones 80mA Supports Eagle 1225 and 1221 boards Keypads 6160 Custom Alpha (required for programming) 100mA 6160V Custom Alpha Voice 100mA 6150 Fixed English LCD 85mA/40mA 6150V Fixed English Voice LCD 85mA/40mA 6150RF Fixed English RF LCD 85mA/40mA 6148 Fixed English LCD 70mA/30mA 6270 touch center Graphic touchscreen 8132 symphony Advanced User Interface Agency Listings UL Residential Fire, Burglary and CSFM Smoke Detectors Supports up to 16 two-wire smoke detectors Supports four-wire smoke detectors Communications Touchtone or pulse Formats supported ADEMCO Contact ID ADEMCO 4 + 2 Express ADEMCO low speed Sescoa/Radionics 3 + 1, 4 + 1 and 4 + 2 reporting Reporting capabilities Split Dual Split/Dual True dial tone detection Low battery reports 11.2 11.6VDC AC loss and restoral reporting supported

doc1

11.75"

24-HR BATTERY STANDBY REQUIRED FOR FIRE INSTALLATIONS. USE 12V, 17.2AH BATTERY FOR 600mA AUX POWER. SEE INSTRUCTIONS. BATTERY CAPACITY FOR EMERGENCY BURGLARY STANDBY USE AT LEAST 4 HRS CHARGING VOLTAGE 13.8VDC. MAXIMUM CHARGING CURRENT 650mA. BATTERY 12V, 4AH 8-PIN CONNECTOR USED FOR 1361X10 TRANSFORMER CONNECTIONS AND FOR ON-BOARD TRIGGERS SEE INSTRUCTIONS. 1 BLACK OUTPUT 17 (TRIG. 1) +12 AUX RED OUTPUT 18 (TRIG. 2) GND FLYING LEADS FOR BATTERY CONNECTION 8
OPTIONAL FOR UP TO 40 ADDITIONAL ZONES ( FROM EITHER OR BOTH GROUPS)
BATTERY FUSE 3A FOR REPLACEMENT, USE SAME VALUE (e.g. ADEMCO No. 90-12)
FOR COMPLETE INFORMATION, SEE INSTRUCTIONS K5305-1V5 OR LATER. (USE SA4120XM-1 CABLE) SYNC COM DATA TO TRANS.

BLK RED GRN YEL

ADEMCO No. 4219 WIRED EXPANSION MODULE (8 ADD'L EOLR WIRED ZONES) -AND/ORADEMCO No. 4229 WIRED EXPANSION/RELAY MODULE (8 ADD'L EOLR WIRED ZONES PLUS 2 OUTPUT RELAYS) -AND/ORADEMCO No. 4204 RELAY MODULE (4 OUTPUT RELAYS) AND/OR ADEMCO 5881* Type RF RECEIVER WIRELESS ZONES 5881L: UP TO 8 5881M: UP TO 16 5881H: UP TO 56 *5882 IN CANADA
4-WIRE SMOKE DETECTOR CONNECTIONS
SET UNITS DIP SWITCH FOR DEVICE ADDRESSES 7 - 15 SEE INSTRUCTIONS.

AUX PWR OUTPUT TERMINALS

RELAY PROGRAM RELAY AS ZONE TYPE 54 (FIRE ZONE RESET) _ 4
RED EOL POWER SUPERVISION RELAY MODULE A77-716B. USE N.O. CONTACT, WHICH CLOSES WHEN POWER IS APPLIED.
CONTACT OPENS MOMENTARILY UPON FIRE ALARM RESET

VIOLET +

SEALED LEAD-ACID TYPE. BATTERY NORMALLY NEED NOT BE REPLACED FOR AT LEAST 3 YRS. TO DETERMINE TOTAL STANDBY LOAD ON BATTERY, ADD 100mA TO TOTAL OF AUX. POWER OUTPUT AND REMOTE KEYPAD CURRENTS. USE UL LISTED LIMITED ENERGY CABLE FOR ALL CONNECTIONS CLASS 2 PLUG-IN TRANSFORMER 16.5VAC, 25VA (e.g. ADEMCO No. 1321). (USE No. 1321CN IN CANADA) USE 1361X10 TRANSFORMER INTERFACE IN PLACE OF 1321 OR 1321CN WHEN POWER LINE CARRIER DEVICES ARE BEING USED. (SEE INSTRUCTIONS FOR CONNECTIONS) THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION'S STANDARD 72, CHAPTER 11 (NATIONAL FIRE PROTECTION ASSOCIATION, BATTERY-MARCH PARK, QUINCY,MA 02169). PRINTED INFORMATION DESCRIBING PROPER INSTALLATION, OPERATION,TESTING, MAINTENANCE, EVACUATION PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH THIS EQUIPMENT.
RED JUMPER CUT FOR BELL SUPERVISION. ALSO, CONNECT 2000 OHM RESISTOR DIRECTLY ACROSS SOUNDER.
TO TERM 4 TO TERM 5 TO TERM 6 TO TERM 7
SET RECEIVERS DIP SWITCH FOR DEVICE ADDRESS OF 0. SEE INSTRUCTIONS.
TO OUTPUT 17 PROGRAM OUTPUT 17 FOR "OUT NORM LOW" = YES IN 79 MENU MODE AND AS ZONE TYPE 54 IN 80 MENU MODE MAX. CURRENT = 100 mA (UP TO 16 DETECTORS PLUS EOL MODULE)

2000 OHMS EOLR

4-WIRE SMOKE OR COMBUSTION DETECTOR
TO ZONE TERM. ( +) TO ZONE TERM. ( _)

HEAT DETECTOR

BLACK: KEYPAD GROUND (- ) RETURN
GREEN: DATA IN FROM KEYPAD

RED: KEYPAD PWR ( + )

6.5"

ZONE 7

ZONE 1

ZONE 2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

ZONE 8
TO 110VAC UNSWITCHED OUTLET (24HR)

YELLOW: KEYPAD DATA OUT

VISTA-20P ONLY
AUX. POWER OUTPUT 10.5-13.8VDC 600mA MAX. (500mA MAX. FOR UL INSTALLATIONS) ALL OUTPUTS ARE POWER LIMITED. BLK
CAN BE USED FOR 2-WIRE SMOKE DETECTORS

TAMPER CONTACTS

CONNECTION OF THE FIRE ALARM SIGNAL TO A FIRE ALARM HEADQUARTERS OR A CENTRAL STATION SHALL BE PERMITTED ONLY WITH THE PERMISSION OF THE LOCAL AUTHORITY HAVING JURISDICTION. THE BURGLAR ALARM SIGNAL SHALL NOT BE CONNECTED TO A POLICE EMERGENCY NUMBER.
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND IC RSS 210. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
+ ALARM OUTPUT 10.513.8VDC, 2A MAX. (600mA MAX. FOR UL USAGE, INCLUDING AUX POWER) STEADY FOR BURGLARY/PANIC, TEMPORAL PULSE SOUNDING FOR FIRE. CAN USE ADEMCO No. 702 SIREN, OR 12V BELL). SEE INSTRUCTIONS.
NOTE: KEYPAD (S) CURRENT (IN BOTH PARTITIONS) AND ALL OTHER DEVICES DRAWING POWER FROM TERMS 4 & 5 MUST BE INCLUDED IN AUX CURRENT DRAIN CALCULATIONS.
REMOTE KEYPADS AND OTHER ADDRESSABLE DEVICES (e.g. 5800TM, 4285/4286, LRR, 4219, 4229, 4204, 5881)
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM. IN ADDITION, THIS SYSTEM MUST BE CHECKED BY A QUALIFIED TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.
REMOTE KEYPADS CAN USE 6150 OR 6160 KEYPADS. LOCAL PROGRAMMING MUST BE DONE WITH A 6139/6160, BUT NEED NOT REMAIN IN THE SYSTEM (SET TO ADDRESS 16).
ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES SUMMARY OF CONNECTIONS
2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 2000 OHMS EOLR 14 MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR) RESPONSE, ZONES 1-8: 10, 350, OR 700 MSEC (PROGRAMMABLE) MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS ON ZONE 1 IS 16; DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A". ZONE PAIRS 10 ZONE 2 3k ZONE 10 2k 2k ZONE 4 ZONE 3 TYPICAL WIRING FOR DOUBLE BALANCED ZONE (VISTA-20P ONLY) / / / / / / / 16 POWER SHUTDOWN NOTE: SYSTEM SHUTS DOWN SENSOR DETECTION PROCESSING IF CONTROL'S VOLTAGE DROPS BELOW 9.6V. ALL DEVICES AND ACCESSORIES USED IN A CANADIAN INSTALLATION MUST BE LISTED FOR USE IN CANADA 6.2k TYPICAL WIRING FOR ZONE DOUBLING (VISTA-20P ONLY) ASSEMBLED IN MEXICO
RING TIP (BROWN) (GRAY) HANDSET

TIP (GREEN)

RING (RED) EARTH GROUND SEE INSTRUCTIONS FOR PROPER GROUNDING
INCOMING PHONE LINE TELEPHONE WIRING (VIA RJ31X* JACK AND DIRECT CONNECT CORD) *CA38A IN CANADA DOC LOAD NO.: 3
FOR CONNECTION OF OPTIONAL 4286 VIP MODULES TO PHONE TERMINALS, SEE INSTRUCTIONS. WARNING:TO PREVENT RISK OF SHOCK, DISCONNECT TELEPHONE LINE AT TELCO JACK BEFORE SERVICING THIS UNIT. COMPLIES WITH FCC RULES, PART 68. FCC REGISTRATION NO. 5GBUSA-44003-AL-E RINGER EQUIVALENCE: 0.1B.

 

Tags

C4000B V-2620DE C5850 I908E FC-39EM Trim KIT DSC-S80 HM108-A IM-MT899H ZCV662MXC Silverado 2003 D-545 Zoom LP-M5500F MX900 UX-J50 PB1860 1 PCI ER-A490 EMP-7350 DSC-S950 83200 EMS2820 KS-FX950R 20VL63 10 0 KP46S25 Xemio-866 Sector MAP QN4041X ML-3470D Review RS20ccsl Legend C Valve F5D5131-8 KR510 30272 HB-B201 SPH-B6650 LG MG64 CT-500J Optipoint S9000 5 SDK L64850 Vivaro Tour ASD 7U C232SF DVD-3800 4 2 Jimmy 1997 TU-PTA100E Ique M3 DD-6200 RE-39NZ43RB ST-AR IRT 3020 ANT70-1400N MZ-E33 157-4 Contax 645 Mpro110 NS-BP110 2-revelation VGP-prtx1 KAC-PS501F 32PC54 DK162 Gz-mg30 Cect F9 PD116 Panasonic GD87 Xv-DV575 T775 HD Sunbeam 4780 32PFL7605H PS-42P2SB SD253 SGH-T309 VMX1000 Etrex H Weider 8920 VGN-AR51SU SCI760W Daikin RYS Techwood PL66 1000 RCA Spider 2000 Megane II TS-WX20LPA GT-I6410 MDR-RF925R Motorola D460 NX6105 GC1815 CDX-GT450 FST-ZX80D SRE 704 Scanjet 3970 Gigaworks T3 DVD-F100

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101