Reviews & Opinions
Independent and trusted. Read before buy AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor!

AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor


Bookmark
AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor

Bookmark and Share

 

About AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor
Here you can find all about AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor like manual and other informations. For example: review.

AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor please write about it to help other people.
[ Report abuse or wrong photo | Share your AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor, size: 447 KB

 

AMX AXC-temp And Rts-1 Temperature Control Card And Room Temperature Sensor

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

SIGCOM, Inc.

GOVERNMENT PRICELIST

Product Number

Description Modero RGB Kits

GSA Price

Warranty

NXT-1200VG RGB Kit

Modero VG Series 12" Table Top with RGB Option, Includes VG Touch Panel, NXAAVB/RGB, NXA-RGB Card, NXA-MTC/RGB Table Top Cable, and TP-RGBCBL Breakout Cable Modero VG Series 15" Table Top with RGB Option, Includes VG Touch Panel, NXAAVB/RGB, NXA-RGB Card, NXA-MTC/RGB Table Top Cable, and TP-RGBCBL Breakout Cable Modero VG Series 17" Table Top with RGB Option, Includes VG Touch Panel, NXAAVB/RGB, NXA-RGB Card, NXA-MTC/RGB Table Top Cable, and TP-RGBCBL Breakout Cable Modero VG Series 12" Wall/Flush Mount with RGB Option, Includes VG Touch Panel, NXA-AVB/RGB, NXA-RGB Card, and TP-RGBCBL Breakout Cable

3 & 1*

NXT-1500VG RGB Kit

NXT-1700VG RGB Kit

NXD-1200VG RGB Kit

NXD-1500VG RGB Kit

Modero VG Series 15" Wall/Flush Mount with RGB Option, Includes VG Touch Panel, NXA-AVB/RGB, NXA-RGB Card, and TP-RGBCBL Breakout Cable

NXD-1700VG RGB Kit

Modero VG Series 17" Wall/Flush Mount with RGB Option, Includes VG Touch Panel, NXA-AVB/RGB, NXA-RGB Card, and TP-RGBCBL Breakout Cable Modero Video Kits
132-8 132-8 132-8 132-8 132-8 132-8
NXT-1200VG Video Kit NXT-1500VG Video Kit NXT-1700VG Video Kit NXD-1200VG Video Kit NXD-1500VG Video Kit NXD-1700VG Video Kit
Modero VG Series 12" Table Top, Includes VG Touch Panel, NXA-AVB/ETHERNET, and Table Top Cable Modero VG Series 15" Table Top, Includes VG Touch Panel, NXA-AVB/ETHERNET, and Table Top Cable Modero VG Series 17" Table Top, Includes VG Touch Panel, NXA-AVB/ETHERNET, and Table Top Cable Modero VG Series 12" Wall/Flush Mount, Includes VG Touch Panel and NXAAVB/ETHERNET Modero VG Series 12" Wall/Flush Mount, Includes VG Touch Panel and NXAAVB/ETHERNET Modero VG Series 12" Wall/Flush Mount, Includes VG Touch Panel and NXAAVB/ETHERNET Modero RGB Kits
3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1*

US US US US US US

132-8 132-8

NXT-1200 NXD-1200

Modero Next Generation 12" Table Top, Black with Platinum Trim Ring Modero Next Generation 12" Wall/Flush Mount, Black with Platinum Trim Ring Modero Color Video (Includes NXA-AVB)

3 & 1* 3 & 1*

132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
NXT-CV7 NXT-CV12 NXT-CV15 NXT-CV17 NXD-CV7 NXD-CV12 NXD-CV15 NXD-CV17
Modero Color Video 7" Widescreen Table Top, Black w/Platinum Trim Ring Modero Color Video 12" Table Top Touch Panel, Black with Platinum Trim Ring Modero Color Video 15" Table Top Touch Panel, Black with Platinum Trim Ring Modero Color Video 17" Table Top Touch Panel, Black with Platinum Trim Ring Modero Color Video 7" Widescreen Wall/Flush Mount w/two Bezel sets (6 programmable buttons and no buttons) Black w/Platinum Trim Ring Modero Color Video 12" Flush Mount Touch Panel, Black with Platinum Trim Ring Modero Color Video 15" Flush Mount Touch Panel, Black with Platinum Trim Ring Modero Color Video 17" Flush Mount Touch Panel, Black with Platinum Trim Ring Modero Color Active
3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1*

US US US US US US US US

132-8 132-8 132-8 132-8
NXT-CA12 NXT-CA15 NXD-CA12 NXD-CA15
Modero Color Active 12" Table Top Touch Panel, Black with Platinum Trim Ring Modero Color Active 15" Table Top Touch Panel, Black with Platinum Trim Ring Modero Color Active 12" Flush Mount Touch Panel, Black with Platinum Trim Ring Modero Color Active 15" Flush Mount Touch Panel, Black with Platinum Trim Ring
3 & 1* 3 & 1* 3 & 1* 3 & 1*

US US US US

GS-35F-5791H
Contract Modification PO0081 Effective September 20, 2005

Page 40

Description
Modero Accessories Computer Control - USB Stick with Windows and MacIntosh Versions of G4 Computer Control (Memory Stick Contains G4CC Application both WIN and MAC, Configuration Utility, NetLinx Sample Code, and Documentation) TakeNote - USB Stick with TakeNote Annotation Application and Computer Control (Memory Stick Contains TakeNote, G4CC Application, Configuration Utility, and Documentation) - Windows Only Audio/Video Breakout Box with Composite Video, and Ethernet Pass Through Audio/Video Breakout Box with RGB/Componenet, Composite Video, and Ethernet Pass Through Audio/Video Breakout Box RGB Upgrade Kit for Modero VG Series, Includes NXA-RGB, NXA-AVB/RGB, NXAMTC/RGB, and TP4-RGBCBL Modero VG Series RGB Option Card Modero Table Top Cable for VG Series (Three CAT-5 cables plus power) 128 MB Compact FLASH Upgrade 256 MB Compact FLASH Upgrade 512 MB Compact FLASH Upgrade 1 GB Compact FLASH Upgrade 128 MB Compact FLASH Upgrade 256 MB Compact FLASH Upgrade 512 MB Compact FLASH Upgrade 1 GB Compact FLASH Upgrade 128 MB SDRAM Upgrade 256 MB SDRAM Upgrade Conduit Box for NXD-CV7 Conduit Box for NXD-CV12 & NXD-CA12 Conduit Box for NXD-CV15 & NXD-CA15 Conduit Box for NXD-CV17 Rack Mount Kit for NXD-CV7 Rack Mount Kit for NXD-CV12 & NXD-CA12 Rack Mount Kit for NXD-CV15 & NXD-CA15 Rack Mount Kit for NXD-CV17 VESA Mount Back Shell Kit for 12" NXD-CV12 & NXDCA12 VESA Mount Back Shell Kit for 15" NXD-CV15 & NXDCA15 VESA Mount Back Shell Kit for 17" Modero Modero Next Generation Series 802.11g Wireless, Upgrade Kit for NXD style panels (Includes, NXA-PCI80211G card and antenna) Modero Next Generation Series 802.11g Wireless Card Modero 802.11b Wireless Network Interface Card for 12", 15", and 17" Touch Panels Modero 802.11b Wireless Network Interface Card for 7" Touch Panels Battery Pack for Modero Battery Base NXA-Base B Modero Battery Base Kit for 12", 15" and 17" NXT Touch Panels (Includes NXABASE/B Modero Battery Base and 2 NXT-BP Modero Power Pack Batteries) Modero 7" Battery Base Kit (Base and Battery) Modero Quick Charger Kit (Includes NXT-CHG Modero Power Station charger and 2 NXT-BP Modero Power Pack Batteries)

NXA-USBCC

NXA-USBTN
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
NXA-AVB/ETHERNET NXA-AVB/RGB NXA-AVB NXA-RGBKIT NXA-RGB NXA-MTC/RGB NXA-CFTP128M NXA-CFTP256M NXA-CFTP512M NXA-CFTP1G NXA-CFSP128M NXA-CFSP256M NXA-CFSP512M NXA-CFSP1G NXA-EM128M NXA-EM256M CB-TP7 CB-TP12 CB-TP15 CB-TP17 NXA-RK7 NXA-RK12 NXA-RK15 NXA-RK17 MB-TP12 MB-TP15 MB-TP17 NXA-WCKIT NXA-PCI80211G NXA-WC80211B NXA-WC80211B/CF NXT-BP
3 & 1* 3 & 1* 3 Years 3 & 1* 3 & 1* 3 & 1* 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 1 Year 1 Year 1 Year 1 Year 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 & 1* 3 & 1* 3 & 1* 3 & 1* N/A
US US US US US US US US US US US US US US US US US US US US US US US US US US US US US US US US

NXA-BASE/B Kit

NXA-BASE/1 Kit NXT-CHG Kit

N/A 3 & 1*

Page 41
Modero ViewPoint Color Wireless Touch Panels

MVP-7500 MVP-8400

Modero ViewPoint 7.5" Passive Display Modero ViewPoint 8.4" Active Matrix Display Modero ViewPoint Accessories
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
MVP-TDS MVP-WDS MVP-BP MVP-KS MVP-STYLUS NXA-WAP200G NXA-WAP2403A NXA-WAP2405A NXA-WAP2410A NXA-WAP2413A CB-MVPWDS
Modero ViewPoint Table Top Docking Station Modero ViewPoint Wall/Flush Mount Docking Station Modero ViewPoint Battery Pack Modero ViewPoint Kick Stand Modero ViewPoint Stylus Pack of 3 802.11g Wireless Acces Point Ceiling Mount Omnidirectional Antenna Option for NXA-WAP200G Rack / Ceiling Mount Ominidirectional Antenna Option for NXA-WAP200G Outdoor Enclosed Yagi Antenna Option for NXA-WAP200G Indoor / Outdoor Directional Panel Antenna Option for NXA-WAP200G Conduit Box for MVP Wall/Flush Mount Docking Station MVP 8400 Experience Kits AMX EXPerience Kit - Hardware included: MVP-8400, NI-3000, NXA-WAP200G, MVPKS, PSN4.4, CC-NET, CC-SER, CC-USB. Software CD with AMX Design tools including: Design XPress & Design XPress - Home Theater, Design XPress Professional, PanelBuilder, PanelPreview AMX EXPerience Kit - Hardware included: MVP-8400, NI-2000, NXA-WAP200G, MVPKS, PSN4.4, CC-NET, CC-SER, CC-USB. Software CD with AMX Design tools including: Design XPress & Design XPress - Home Theater, Design XPress Professional, PanelBuilder, PanelPreview MVP 7500 Experience Kits AMX EXPerience Kit - Hardware included: MVP-7500, NI-3000, NXA-WAP200G, MVPKS, PSN4.4, CC-NET, CC-SER, CC-USB. Software CD with AMX Design tools including: Design XPress & Design XPress - Home Theater, Design XPress Professional, PanelBuilder, PanelPreview AMX EXPerience Kit - Hardware included: MVP-7500, NI-2000, NXA-WAP200G, MVPKS, PSN4.4, CC-NET, CC-SER, CC-USB. Software CD with AMX Design tools including: Design XPress & Design XPress - Home Theater, Design XPress Professional, PanelBuilder, PanelPreview Touch Panel Interface 4

3 Years 3 Years N/A 1 Year 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 1 Year
US US US US US US US US US US US

EXP-8430

EXP-8420

EXP-7530

EXP-7520

132-8 132-8 132-8

NXP-TPI/4 TP4-VID TP4-RGB
NetLinx Touch Panel Interface 4 TPI/4 Video Input Card TPI/4 RGB and VGA Input Card Touch Panel Interface Accessories

3 & 1* 1 Year 1 Year

US US US
132-8 132-8 132-8 132-8 132-8 132-8 132-8
TP4-RGBCBL NXA-CFTPI128M NXA-CFTPI256M NXA-CFTPI512M NXA-CFTPI1G NXA-EXM128M NXA-EXM256M
RGB Breakout Cable, 15 Pin Female 128 MB Compact FLASH Upgrade for TPI MB Compact FLASH Upgrade for TPI MB Compact FLASH Upgrade for TPI GB Compact FLASH Upgrade for TPI MB SDRAM Upgrade for TPI MB SDRAM Upgrade for TPI 4 ViewPoint Color Wireless Touch Panels Note: All ViewPoint Touch Panels also provide 38/455 KHz IR transmission
1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

US US US US US US US

VPN-CP
2-Way ViewPoint Color Wireless Touch Panel, 2.4 GHz, Black (includes VPA-BP battery) 1-Way ViewPoint Color Wireless Touch Panel, Black. Includes VPA-BP battery (Radio Frequencies available: 304, 310, 315, 418, 433 MHz). Specify required frequency. ViewPoint Rechargeable Battery (NiMH) ViewPort Docking Station, Black NetWave Server (NetWave 2-way 2.4 GHz receiver, AXLink)

VPT-CP

VPA-BP VPA-DS AXR-NWS

N/A 3 Years 3 Years

Page 42
1-Way Wireless RF and IR Receivers
132-8 132-8 132-8 132-8 132-8
AXR-RF AXR-IRSM+ AXD-IR+ IRX-SM+ IRX-DM+
RF Receiver, AXLink (Specify required frequency: 304, 310, 315, 418, 433 MHz) Swivel Mount IR Receiver (AXlink, 38/455 kHz IR) Flush Mount IR Receiver, AXLink, 38/455 kHz IR (Specify Black or White) Swivel Mount IR Sensor (38/455 kHz IR) Flush Mount IR Sensor, 38/455 kHz IR (Specify Black or White) 10.4" Color Graphic Active-Matrix LCD
3 Years 3 Years 3 Years 3 Years 3 Years

US US US US US

AXT-CG10 AXD-CG10 AXD-CG10/PB AXM-CG10 AXM-CG10/PB
10.4" Color Graphic Table Top, Black 10.4" Color Graphic Flush/Wall Mount Touch Panel (Specify Black, White or Ivory) 10.4" Color Graphic Flush/Wall Mount Touch Panel, External Pushbuttons (Specify Black, White or Ivory) 10.4" Color Graphic Rack Mount Touch Panel, Black 10.4" Color Graphic Rack Mount Touch Panel, External Pushbuttons, Black 10.4" Color Video Active-Matrix LCD

3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1*
AXT-CV10 AXD-CV10 AXD-CV10/PB AXM-CV10 AXM-CV10/PB
10.4" Color Video Table Top Touch Panel, Black 10.4" Color Video Flush/Wall Mount Touch Panel (Specify Black, White or Ivory) 10.4" Color Video Flush/Wall Mount Touch Panel, External Pushbuttons (Specify Black White or Ivory) 10.4" Color Video Rack Mount Touch Panel, Black 10.4" Color Video Rack Mount Touch Panel, External Pushbuttons, Black 10.4" Color Active-Matrix LCD
AXT-CA10 AXD-CA10 AXD-CA10/PB AXM-CA10 AXM-CA10/PB CB-TP3 EXM-1MB
10.4" Color Active Table Top, Black 10.4" Color Active Flush/Wall Touch Panel (Specify Black, White or Ivory) 10.4" Color Active Flush/Wall Touch Panel, External Pushbuttons (Specify Black, White or Ivory) 10.4" Color Active Rack-Mount Touch Panel, Black 10.4" Color Active Rack-Mount Touch Panel, External Pushbuttons, Black Conduit Box for AXD-CA10/CV10/CGMB Extended Memory for AXT-CP (8.5" Color Touch Panels, LC w/G3 Firmware) 6" Color Video Touch Panels
3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 1 Year 3 & 1*

AXD-CV6 CB-CV6

6" Color Video Flush/Wall Mount Touch Panel (Specify Black or White) Conduit Box for AXD-CV6 Touch Panel 6" Table Top Enclosure

3 & 1* 1 Year

AC-CV6T
Table Top Enclosure for AXD-CV6 (Specify Dark Gray, Platinum or Paintable Unfinished Aluminum) 5.5" Color Passive-Matrix LCD

3 Years

AXT-MCP AXT-MCP/PB AXD-MCP AXD-MCP/PB AXM-MCP AXM-MCP/PB CB-MTP
5.5" Color Table Top Mini Touch Panel, Black 5.5" Color Table Top Mini Touch Panel, External Pushbuttons, Black 5.5" Color Flush/Wall Mount Mini Touch Panel (Specify Black, White or Ivory) 5.5" Color Flush/Wall Mount Mini Touch Panel, External Push (Specify Black, White or Ivory) 5.5" Color Rack+D207 Mount Mini Touch Panel, Black 5.5" Color Rack Mount Mini Touch Panel, External Pushbuttons, Black Conduit Box for AXD-MCP and AXD-MCP/PB
3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 3 & 1* 1 Year

Page 43

4" Color Passive-Matrix LCD with Audio

AXT-CP4/A AXD-CP4A AC-CP4/WRB CB-CP4/A
4" Color Table Top Touch Panel with Audio (Specify Dark Gray or Platinum) 4" Color Flush/Wall Mount Touch Panel w/Audio (Specify 3 color Bezel, Black, Almond or White) Water Resistant Bezel Set of (1 white, 1 black, 1 almond) for AXD-CP4/A Conduit Box for AXD-CP4/A LCD Touch Monitor
3 & 1* 3 & 1* 3 & 1* 1 Year
PTM-D15 VTM-D15/A VTM-D15/AB VTM-WMB
Platinum Series 15" Multimedia Touch Monitor 15" Table Top Touch Monitor 15" Table Top Touch Monitor plus Surface Mount Bracket Wall Mounting Bracket for VTM-D15/A 15" Multimedia System
VTM-D15/AS VTM-D15/ASB PTM-D15/AS PTM-D15/ASRGB AXB-TPI/3 TP3-VID TP3-RGB TP3-VGA
VTM-D15/A MultiMedia Table Top System, includes 15" VTM-D15/A, AXB-TPI/3 and TP3-VID VTM-D15/A MultiMedia Surface Mount System, includes 15" VTM-D15/A, AXB-TPI/3 and TP3-VID PTM-D15/A MultiMedia Surface Mount System, includes 15" PTM-D15, NXP-TPI/4 and TP4-VID PTM-D15/A MultiMedia Table Top System includes 15" PTM-D15, NXP-TPI/4 and TP4RGB Touch Panel Interface 3 TPI/3 Video Input Card TPI/3 RGB Input Card TPI/3 VGA Input Card TXC Remotes
3 & 1* 3 & 1* 3 & 1* 3 & 1* 1 Year 1 Year 1 Year 1 Year
TXC-24IR TXC4+ TXC4L+ TXC16+ TXC32+
24-Button, Credit Card IR Remote 4-Button Transmitter, 38/455 kHz IR (Specify required frequency: 304, 310, 315, 418, 433 MHz) 4-Button Transmitter with Laser Pointer, 38/455 kHz IR (Specify required frequency: 304, 418 MHz) 16-Button Transmitter, 38/455 kHz IR (Specify required frequency: 304, 310, 315, 418, 433 MHz) 32-Button Transmitter, 38/455 kHz IR (Specify required frequency: 304, 310, 315, 418, 433 MHz) 2-Way Wireless Receiver

AXR-NWS NWA-EXT

NetWave Server (NetWave 2-way 2.4 GHz receiver, AXLink) NetWave Server External Antenna (6 foot cable) DMS Keypads

3 Years 3 Years

PLK-DMS PLK-DIAG
Direct Menu Select Keypad, Downloadable NetLinx Module required / Landmark ready (Specify Black, White, Ivory or Almond) Landmark DMS Diagnostic Keypad SB Keypads

PLK-SB

1 and 2 Button Flush Mount Keypad, Decora style, Downloadable NetLinx Module required / Landmark ready (Specify Black, White or Ivory Decora Style. Faceplate Not Included) Wired Keypads

AXD-MSP8 AXD-MSP16 AXD-MSP32
Softwire 8-Button Keypad, AXLink, 1 bargraph, 1 gang (Specify Black, White or Ivory) Softwire 16-Button Keypad, AXLink, 2 bargraph, 2 gang (Specify Black, White or Ivory) Softwire 32-Button Keypad, AXLink, 3 bargraph, 3 gang (Specify Black, White or Ivory) Wired Panels
3 & 1* 3 & 1* 3 & 1*
AXM-MSP32 AXU-SP+ AXM-SP+
Softwire 32-Button Keypad Rack Mount (2 rack spaces, 3 bargraphs) UniMount Softwire Panel (up to 64 buttons, 3 bargraphs) Rack-Mount Softwire Panel (up to 64 buttons, 3 bargraphs)

Page 44

CB-SP+ Conduit Box for AXU-SP+

1 Year

Mini-LCD Panels 132-8 132-8 132-8 AXP-MLCD AXU-MLCD CB-MLCD Mini-LCD Panel UniMount Mini-LCD Panel Conduit Box for AXU-MLCD Custom Panel Interfaces 132-8 132-8 132-8 132-8 132-8 132-8 132-8 NXP-CPI16 AXP-AI8 AXP-CPI AXP-CPI16 AXP-CPIL WPD8 WPDR NetLinx Custom Panel Interface (16 inputs/outputs and 2 quadrature inputs) Analog 8-Input Board (joystick and potentiometer interface) Custom Panel Interface (up to 64 buttons, 4 bargraphs) Custom Panel Interface Board (up to 16 buttons or 16 inputs/outputs) LED Custom Panel Interface Board (up to 64 buttons, 2 bargraphs) 8-Button Low Voltage Keypad (Specify Black, White or Ivory) SPDT Rocker Switch (Specify Black, White or Ivory) NetLinx Integrated Controllers 132-8 132-8 132-8 NI-700 NI-2000 NI-3000 Small Room Integrated Master/NetLinx controller: 1 IR Port, 4 I/O Ports, 1 IR Input Port and 2 RS-232/422/485 Ports, with Ethernet and AxLink in a 1/3 Rack Width Form Factor Integrated Master/NetLinx controller in a single unit with same functionality of NXI and ME260, 4 IR Ports, 4 I/O Ports, 4 Relays, and 3 RS-232/422/485 Ports Integrated Master/NetLinx controller in a single unit with same functionality of NXI and ME260, 8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232/422/485 Ports Integrated Master/NetLinx controller in a single unit with same functionality of NXI and ME260, 8 IR Ports, 8 I/O Ports, 8 Relays, and 7 RS-232/422/485 Ports with 4 NXC Card Slots NetLinx Contoller and CardFrame 132-8 132-8 132-8 132-8 132-8 NXI (1-3) NXI (4-11) NXI (12+) NXF NXF-MINI NetLinx Integrated Controller (Controller only, requires Master or Hub Card) Quantity 13 NetLinx Integrated Controller (Controller only, requires Master or Hub Card) Quantity 411 NetLinx Integrated Controller (Controller only, requires Master or Hub Card) Quantity 12+ NetLinx CardFrame with 12 card slots (CardFrame only, requires Master or Hub Card) NetLinx Mini CardFrame, ICSNet Interface with 4 NetLinx Card, Card Slots NetLinx Master Cards and Modules 132-8 NXC-ME260 NetLinx Master260 Card, Ethernet NetLinx Hub Cards and Modules 132-8 132-8 132-8 132-8 132-8 NXS-NMS NXC-NH NXC-HS NXC-HE NXS-MHS NetModule Shell (houses all NXC control cards) NetLinx ICSNet Hub Card NetLinx ICSHub Server Card NetLinx ICSHub Expander Card Master/Hub Module Shell (includes faceplates for Master and Hub) NetLinx Control Cards 132-8 132-8 132-8 132-8 132-8 132-8 NXC-IRS4 NXC-COM2 NXC-REL10 NXC-I/O10 NXC-VAI4 NXC-VOL4 4-Port IR/S Card, 4 IR/S and 4 inputs Dual COM Port Card, 2 RS-232/422/485 Relay Card, 10 Channels Input/Output Card, 10 Channels Voltage Output/Analog Input Card, 4 Channels Volume Card, 4 Channels NetLinx System Accessories 132-8 132-8 132-8 132-8 AC-SMB NXA-CFNI64M NXA-CFNI128M NXA-CFNI256M Surface Mount Bracket Set for NI-700 Controller NXA-CFNI64M, NI-XXXX 64MB Flash Upgrade NXA-CFNI128M, NI-XXXX 128 MB Flash Upgrade NXA-CFNI256M, NI-XXXX 256MB Flash Upgrade 1 Years 3 Years 3 Years 3 Years US US US US 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years US US US US US US 3 Years 3 Years 3 Years 3 Years 3 Years US US US US US 3 Years US 3 Years 3 Years 3 Years 3 Years 3 Years US US US US US 3 & 1* 3 & 1* 3 & 1* US US US 3 Years 3 Years 3 Years 3 Years 3 Years 1 Years 1 Years US US US US US US US 3 & 1* 3 & 1* 3 Years US US US

NI-4000

Page 45
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
NXA-CFNI512M NXA-CFNI1G NXA-CFM32M NXA-CFM64M NXA-CFM128M NXA-CFM256M NXA-CFM512M NXA-CFM1G EXA NCK
NXA-CFNI512M, NI-XXXX 512 MB Flash Upgrade NXA-CFNI1G, NI-XXXX 1GB Flash Upgrade 32MB Compact FLASH Upgrade for ME260 64MB Compact FLASH Upgrade for ME260 128MB Compact FLASH Upgrade for ME260 256MB Compact FLASH Upgrade for ME260 512MB Compact FLASH Upgrade for MEGB Compact FLASH Upgrade for ME260 Ethernet Crossover Adapter NetLinx Connector Kit NetLinx Wireless System Package NetLinx 2-Way Wireless System Package: Includes 2-way ViewPoint (VPN-CP), NiMH battery pack (VPA-BP), docking station (VPA-DS), charging power supply (PS2.8), NI2000 w/power supply (PSN2.8), NetWave server (AXR-NWS), programming cables and 2 IR Emitters. Quantity 1-3 NetLinx 2-Way Wireless System Package: Includes 2-way ViewPoint (VPN-CP), NiMH battery pack (VPA-BP), docking station (VPA-DS), charging power supply (PS2.8), NI2000 w/power supply (PSN2.8), NetWave server (AXR-NWS), programming cables and 2 IR Emitters. Quantity 4+ NetLinx 1-Way Wireless System Package: Includes 1-way ViewPoint (VPT-CP), charging power supply (PS2.8), NiMH battery pack (VPA-BP), docking station (VPADS), power supply (PSN2.8), receiver (AXR-RF), programming cable and 2 IR Emitters. (Specify Frequency Required: 304, 310, 315, 418, 433 MHz) Quantity 1-3 NetLinx Wireless System Package, 1 Way (Specify Frequency Required: 304, 310, 315, 418, 433 MHz) Quantity 4+ NetLinx Platinum Series Solutions
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years
US US US US US US US US US US

NI-CPNW (1-3)

NI-CPNW (4+)

VPX-CPNI (1-3)

VPX-CPNI (4+)
132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33
NSK-DEDU NSS-DEDU NSK-PEDU NSS-PEDU NSK-DENT NSS-DENT NSK-PENT NSS-PENT NSK-DPRES NSS-DPRES NSK-PPRES NSS-PPRES NSS-VOTE
Education Solution System, Deluxe Edition Education Solution Software, Deluxe Edition Education Solution System, Premium Edition Education Solution Software, Premium Edition Entertainment Solution System, Deluxe Edition Entertainment Solution Software, Deluxe Edition Entertainment Solution System, Premium Edition Entertainment Solution Software, Premimum Edition Presentation Solution System, Deluxe Edition Presentation Solution Software, Deluxe Edition Presentation Solution System, Premium Edition Presentation Solution Software, Premimum Edition Voting Software Solution integration! Solutions
90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days 90 Days

US US US US US US US US US US US US US
132-33 132-33 132-33 132-33 132-33 132-33 132-33 132-33
FG070-512 FG070-503 FG070-511 FG070-510 FG070-509 FG070-515 FG070-517 FG070-520
i!-Database Plus - Access network databases using NetLinx i!-EquipmentMonitor - Receive email alerts of system events i!-FTPSender - Load files into NetLinx from FTP servers i!-PCLink PowerPoint - AMX controls PowerPoint presentations i!-PCLink Web - Launch PC applications from a Touch Panel i!-Schedule - Control systems events based on date/time i!-TimeManager - Set internal clock from internel server i!-WebControl - Control system from internet web pages
Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com Available at no charge at www.amx.com

Page 46

NetLinx Software Solutions MeetingManager 1.x

132-33 132-33

NSS-MMSV NSS-MMCL
MeetingManager Application with 2 NetLinx Mater Licenses Single (1) NetLinx Master License for Meeting Manager MeetingManager 2.0

1 Year 1 Year

132-33 132-33 132-33 132-33
NSS-MMSV NSS-MMCL NSS-PFFRAME NSS-WEATHER
MeetingManager Application with 2 NetLinx Mater Licenses (Available as free upgrade to any MeetingManager 1.0 pkg purchase prior to Oct 1, 2004. Single (1) NetLinx Master License for MeetingManager (Available as free upgrade to any MeetingManager 1.0 pkg purchase prior to Oct 1, 2004. Picture Frame Application i!-Weather NetLinx Applicayion - Control events based on weather conditions (Includes software & 3 yr subscription to weather services) Input Sensors
1 Year 1 Year 1 Year 1 Year

PCS PCS2 VSS2 RTS-1 TVS

Power Current Sensor (110VAC only) Dual Power Current Sensor (110VAC only) Video Sync Sensor (2 I/O channels) Room Temperature Sensor (requires AXC-TEMP card) TV Sensor Contact Closure Interfaces
1 Year 1 Year 1 Year 1 Year 1 Year

AV2SM PC1 PC2 UPC20+

Auto/Manual Video Switcher (2 x 1 video/stereo audio follow) Power Controller,10 A (110 VAC only) Dual Power Controller, 5 A (110 VAC only) Universal Power/Motor Controller, 20 A (110/220 VAC) System Tools
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8

EXA ABS STS IRIS PM-TERM PSN2.8 PSN6.5 FG423-05 FG423-11 PS4.4 PSN.4 PS-PT2 PS24VAC
Ethernet Crossover Adapter AXlink Bus Strip Serial To Screw terminal adapter (DB9 female to screw terminals) IR/Serial Data Capture Device ICSNet 120Ohm Terminator (20 pack) 12VDC, 2.8A Power Supply (NetLinx) (regulated, 110/220VAC input, 3.5 mm 2 pin Phoenix Connector) 12VDC, 6.5A Power Supply (regulated, 110/220VAC input) 12VDC, 2.8A Power Supply (Axcess) (regulated, 110/220VAC input, 3.5 mm 2 pin Phoenix Connector) 12VDC, 2.8A Power Supply (ViewPoint) (regulated, 110/220VAC input, 2.1 mm barrell plug) 12VDC, 4.4A Power Supply (MVP's and MVP-TDS) (regulated, 110/220VAC input, 6.0mm barrell plug) Power Supply for MVP-WDS Docking Station 24 VDC, 1.6 A Power Supply (regulated, 110/220 VAC input) ViewStat 24VAC Power Supply AMX Standard 10 ft. Third Party Cables (Please call SIGCOM for quote on longer length cables)
1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year
CC-IRC CC-NIRC CC-IRX CC-COM CC-232 CC-USB
IR Emitter Cable (Please specify third party device) NetLinx IR Emitter Cable (Please specify third party device) CC-IR AMX TV Sensor Cable AMX Programming Cable (9-Pin to 9-Pin) Serial Communication Cable - Please specify third party device USB Programming Cable for CV7 and MVP Mounting Hardware
1 Year 1 Year 1 Year 1 Year 1 Year 1 Year

CSB CSB2 AC-RK AC-RK3

Cable Support Bracket (NetLinx, Axcent3, and AXF-MINI) Cable Support Bracket (AXF-BP) Accessory Rack Kit (3 module capacity, single rack unit height) Extended Length Rack Mount (AXCENT3)
3 Years 3 Years 3 Years 3 Years

Page 47

TMX-CB TMX-RK+ TMX-SM
Cable Security Bracket for AXB-TMC/TMX+ Rack Mount Kit for AXB-TMC/TMX+ Surface Mounting Kit for AXB-TMC/TMX+ Special Services

3 Years 3 Years 3 Years

CL-EN LP-EN REN-ACF REN-TP REN-16 REN-32 REN-64
Digitization and Placement (custom logo or graphic) Placement from Existing File (custom logo or graphic) Reverse Engraved Additional Color (per color) Engraved Overlay, Touch Panel (Rackmount Panels) Engraved Overlay, 1-16 Buttons Engraved Overlay, 17-32 Buttons Engraved Overlay, 33-64 Buttons ViewStat Communicating Thermostat System
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
VST VST-TSTAT VST-MVRT VST-DIST VST-TTM VST-TRH VST-TSF VST-TSO PS24VAC
ViewStat Thermostat with MiniVerter ViewStat Thermostat MiniVerter Distribution Panel ViewStat Dual Temperature Support Module ViewStat Temperature-Humidity Support Module ViewStat Remote Temperature Sensor, Indoor Flush Mount ViewStat Remote Temperature Sensor, Outdoor/Duct Mount 24VAC Power Supply Equipment Protection
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 1 Year
US US US US US US US US US

NXA-UPS9510

Uninterruptible Power System with surge pretection and power outage support. 1000/650 VA/W capacity (120V/240V Input, Output is 120V to 8 NEMA 5-15R Outlets) Multi-Port Surge Protection for RJ45 communications ports (Port 1 - Ethernet, Ports 216 -NetLinx Protocols) Individual Node Surge Protection Multi-Media Server (MMS)

NXA-MPS16F NXA-TSJ45

MAX-MMS-01S MAX-MMS-02S MAX-MMS-02SB MAX-MMS-04S MAX-MMS-12S MAX-MMS 900M
625 CD / 25 DVD Capacity with 2 audio zone outputs 1250 CD / 50 DVD Capacity with 2 audio zone outputs 625 CD / 25 DVD Capacity with 2 audio zone outputs w/RAID backup 1250 DC / 100 DVD Capacity with RAID 5 Backup, 4 Hot Swappable Disk Drives, and Ethernet Out 7500 DC / 300 DVD Capacity with RAID 5 Backup 900 DVD Capacity Raid 5 Backup, Ethernet Out Audio Only Module (AOM)
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years

MAX-AOM MAX-AOM-EX

Audio Only Module that support 4 Audio Zones (USB Connection to MMS-xxS Servers) Expansion Audio Only Module that mounts beside the MAX-AOM and support 4 additional Audio Zones (USB Connection to MMS-xxS Servers) Audio/Video Module (AVM) - Need 1 for each output zone of (MMS)

MAX-AVM

Audio and Video output, Ethernet in Intergrated Music Server (IMS)
MAX-IMS500-2 MAX-IMS500-4 MAX-IMS1000-2 MAX-IMS1000-4 MAX-IMS 1500-2 MAX-IMS 1500-4 MAX-IMS 2500-2 MAX-IMS 2500-4
500 CD Capacity, 2 audio outputs 500 CD Capacity, 4 audio outputs 1000 CD Capacity, 2 audio outputs 1000 CD Capacity, 4 audio outputs 1500 CD Capacity, 2 audio outputs 1500 CD Capacity, 4 audio outputs 2500 CD Capacity, 2 audio outputs 2500 CD Capacity, 4 audio outputs Multi-Media Server (MMS)
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years

MAX-MMS 125

125 DVD Capacity Raid 5 backup, Ethernet out

Page 48

MAX-MMS 200 MAX-MMS 300 MAX-MMS 350 MAX-MMS 400M
200 DVD Capacity Raid 5 backup, Ethernet out 300 DVD Capacity Raid 5 backup, Ethernet out 350 DVD Capacity Raid 5 backup, Ethernet out 400 DVD Capacity Raid 5 backup, Ethernet out Backup Storage Module (BSM)
MAX-BSM500 MAX-BSM1000 MAX-BSM1500 MAX-BSM2500
Automated Backup of up to 500 CDs Automated Backup of up to 1000 CDs Automated Backup of up to 1500 CDs Automated Backup of up to 2500 CDs AMX InConcert with Lutron
ALD-D48 ALD-1000D ALD-600D ALD-1000NS ALD-VETS-R ALD-VWP-2 ALD-VWP-3 ALD-VWP-4

Dimmer Interface Lutron 1000 Watt lighting dimmer Lutron 600 Watt lighting dimmer Lutron 1000 Watt lighting switch Lutron Auxiliary Switch Lutron 2 Gang Wall plate Lutron 3 Gang Wall plate Lutron 4 Gang Wall plate Radia Lighting Control Enclosures
RDA-ENC2 RDA-ENC4 RDA-ENC6 RDA-ENC8W RDA-ENC6B / 120 RDA-ENC6B / 240 RDA-ENC12B / 120 RDA-ENC12B / 240
2-space enclosure 4-space enclosure 6-space enclosure 8-Space Enclosure 6-Space Enclosure with Breakers (120VAC) 6-Space Enclosure with Breakers (240VAC) 6-Space Enclosure with 12 Breakers (120VAC) 6-Space Enclosure with 12 Breakers (240VAC) Radia Control Cards
RDC-DC/120 RDC-DC/240 RDC-DC/277 RDC-PDC/120 RDC-PDC/240
Radia Control Card, 6 Channel Dimmer (120VAC) Radia Control Card, 6 Channel Dimmer (240VAC) Radia Control Card, 6 Channel Dimmer (277VAC) Radia Pro Control Card, dual or three phase (120VAC) Radia Pro Control Card, dual or three phase (240VAC) Integrated Dimmer Modules
RDD-DM6/120 RDD-DM6/240 RDD-DM6/277 RDD-DM4/120 RDD-DM4/240 RDD-DM4/277
6-Channel Integrated Dimmer Module (120VAC) 6-Channel Integrated Dimmer Module (240VAC) 6-Channel Integrated Dimmer Module (277VAC) 4-Channel Integrated Dimmer Module (120VAC) 4-Channel Integrated Dimmer Module (240VAC) 4-Channel Integrated Dimmer Module (277VAC) Radia Dimmer Modules
RDM-INC RDM-2INC RDM-INC50 RDM-MDM RDM-DC RDM-2DC RDM-3DC RDM-HDC RDM-FDB
Incandescent Dimmer Module, 2400 W Dual Incandescent Dimmer Module, 2400 W (x2) Incandescent Dimmer Module, 6000 W Multimodule Dimmer Module, 2400 W DC Module, 1920W, 0-10VDC Dual DC Module, 1920W (x2), 0-10VDC Triple DC Module, 1920W (x3), 0-10VDC Heavy Duty DC Module, 2400W, 0-12 VDC FDB Module, 1920 W
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years

Page 49

RDM-2FDB RDM-3FDB RDM-HFDB Dual FDB Module, 1920 W (x2) Triple FDB Module, 1920 W (x3) Heavy Duty FDB Module, 2400 W
Radia Switch Modules 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 RDM-3EM RDM-6EM RDM-SWM RDM-2SWM RDM-3SWM RDM-DPSM RDM-ZC RDM-2ZC RDM-ZCCircuit Switching Module (up to 20 amps) 6 Circuit Switching Module (up to 20 amps) Switch Module, 2400W Dual Switch Module, 2400W (x2) Triple Switch Module, 2400W (x3) Double Pole Single Throw Module, 20A Zero Cross Module, 2400W Dual Zero Cross Module, 2400W (x2) Zero Cross Module, 6000W Pro Dimmer Kits 132-8 132-8 132-8 132-8 RDK-ENC6B/120 RDK-ENC6B/240 RDK-ENC12B/120 RDK-ENC12B/Channel Pro Dimmer Kit 120VAC (includes: RDC-PDC/ 120, RDA-ENC6B/ 120) 6 Channel Pro Dimmer Kit 240VAC (includes: RDC-PDC/ 240, RDA-ENC6B/240) 12 Channel Pro Dimmer Kit 120VAC (includes: (x2) RDC-PDC/120, RDAENC12B/120) 12 Channel Pro Dimmer Kit 240VAC (includes: (x2) RDC-PDC/240, RDAENC12B/240) Dimmer Accessories 132-8 132-8 132-8 132-8 RDA-PSM RDA-CKM RDA-DIV RDA-EFP 12 VDC 2.5 Amp power supply module Dual Choke Module Module divider Enclosure filler plate Radia PROLink Wall Panels 132-8 132-8 PRO-DP8 PRO-DP16 PROLink Wall Panel, single gang (Specify Black, White or Ivory) PROLink Wall Panel, 2 gang (Specify Black, White or Ivory) Camera Controllers 132-8 132-8 132-8 AXP-PLV AXP-CCS AXM-CCS PosiTrack Pilot Controller Softwire Camera Center Rack-Mount Softwire Camera Center PosiTrack Pan/Tilt Heads 132-8 132-8 AXB-PT15 AXB-PT30 PosiTrack Camera Controller, 15lb (AXLink) PosiTrack Camera Controller, 30lb (AXlink) Camera Control Accessories 132-8 132-8 132-8 WM-CAM PM-CAM TM-CAM PosiTrack Wall or Ceiling Mount PosiTrack Pedestal Mount PosiTrack Tripod Mount Adapter ViewPoint Xpress 2-Way Wireless Systems Includes ViewPoint Wireless Touch Panel (VPN-CP) with charging power supply (PS2.8), NiMH battery pack (VPA-BP), Axcent 3 (AXCENT3), power supply (PS2.8), RF NetWave receiver (AXR-NWS), programming cable and 4 IR Emitters. 132-8 VPX-CPNW ViewPoint Xpress Color System (NetWave 2-way 2.4 gHz RF) 3 Years US 3 Years 3 Years 3 Years US US US 1 Year 1 Year US US 3 Years 3 Years 3 Years US US US 3 Years 3 Years US US 1 Year 3 Years 3 Years 3 Years US US US US 3 Years 3 Years 3 Years 3 Years US US US US 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years US US US US US US US US US

Page 50

ViewPoint Xpress 1-Way Wireless Systems Includes ViewPoint Wireless Touch Panel (VPT-CP) with charging power supply (PS2.8), NiMH battery pack (VPA-BP), Axcent 3 (AXCENT3), power supply (PS2.8), IR or RF AXLink receiver (AXD-IR, AXR-RF), programming cable and 4 IR Emitters.

VPX-CP VPX-CPIR

ViewPoint Xpress Color System, 1-way RF (Specify required frequency: 304, 310, 315, 418, 433 MHz; 1-way RF). ViewPoint Xpress Color System (38/455 kHz, IR Only) Axcent 3

3 AXCENT 1-3

Integrated AXCESS System (quantity 1-3) Integrated AXCESS System (quantity 4-11) Integrated AXCESS System (quantity 12+) Integrated AXCESS ControlFrame (quantity 1-3) Integrated AXCESS ControlFrame (quantity 4-11) Integrated AXCESS ControlFrame (quantity 12+) Enhanced Master/RS-232 Controller AXCESS Card Frames
3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years
AXCENT3 4-11 AXCENT3 12+ AXCENT3 PRO 1-3 AXCENT3 PRO 4-11 AXCENT3 PRO 12+ AXB-EM232
AXF-M/S AXF-S AXF-MINI AXB-MPE+ AXB-SPE
Master CardFrame (with AXC-EM and AXC-S cards) Server CardFrame (with AXC-S card) Mini-CardFrame (up to 3 AXC-control cards) Master Port Expander (with AXC-EM card) Server Port Expander (requires AXB-MPE) Axcess Processor Cards

AXC-EM AXC-S

Enhanced System Master Card CardFrame Server Card Data Control Cards
AXC-232 AXC-232++ AXC-IR/S AXC-SMP AXC-MIDI AXC-X10
RS-232/422/485 Interface Card RS-232/422/485 Interface Card (enhanced functionality) IR/Serial Card (includes IR Emitter) SMPTE Time Code Card MIDI Interface Card (with one MIDI cable) X-10 Interface Card (includes power line module) Contact Closure Cards
AXC-INP8 AXC-REL8 AXC-REL14 AXC-SAV AXC-SLD
8 Input Card (8 switch/opto-logic voltage inputs) 8 Relay Card (independent relay commons) 14 Relay Card (single common or 2 groups of 7 relays) SAV Slide Projector Card (SAV series) Slide Projector Card (US Kodak series) Audio Control Cards

AXC-VOL

2-Channel Volume Control Card (line-level audio) Voltage Ramp Cards

AXC-PTI AXC-VAI2 AXC-VG24 AXC-VRG4
Pan/Tilt Interface Card (requires pan/tilt power supply) Voltage Output/Analog Input Card (2 voltage outputs, 2 analog inputs) Voltage Ramp Generator Card (4 voltage outputs, 0/+24 VDC) Voltage Ramp Generator Card (4 voltage outputs, 12/+12 VDC) Special Application Cards

AXC-EXTN AXC-TEMP

Extender Card Temperature Control Card (includes RTS-1 sensor) Data Controllers

AXB-232++

RS-232/422 Interface (enhanced functionality)

Page 51

AXB-DMX512 AXB-DTMF+ AXB-IRS4 AXB-MIDI AXB-PCCOM AXB-TC AXB-TCR AXB-TM5 AXB-TMC AXB-TMX+ DMX 512 Interface DTMF Interface IR/Serial Interface, 4 Ports MIDI Interface
AXlink-to-PC Communications Port Interface Television Controller Television Controller/Receiver (38 kHz IR) Television Manager (38/455 kHz IR) Television Manager+, with clock (38/455 kHz IR) Television Manager+, (38/455 kHz IR) Audio Controllers

AXB-VOL3

3-Channel Volume Controller (line-level audio) Contact Closure Controllers

AXB-REL8 AXB-SLD

Relay Controller (8 relays, independent commons) Slide Controller (120 VAC only, includes US Kodak cable) MX Single Projector Controllers
132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8 132-8
MX2 (1-3) MX2 (4-11) MX2 (12+) MX3 (1-3) MX3 (4-11) MX3 (12+) MX4 (1-3) MX4 (4-11) MX4 (12+) MX4A (1-3) MX4A (4-11) MX4A (12+)
Fwd, Rev (Quantity: 1-3) Fwd, Rev (Quantity: 4-11) Fwd, Rev (Quantity: 12+) Fwd, Rev, On/Off (Quantity: 1-3) Fwd, Rev, On/Off (Quantity: 4-11) Fwd, Rev, On/Off (Quantity: 12+) Fwd, Rev, Focus In/Out (Quantity: 1-3) Fwd, Rev, Focus In/Out (Quantity: 4-11) Fwd, Rev, Focus In/Out (Quantity: 12+) Fwd, Rev, Focus In/Out, On/Off (Quantity: 1-3) Fwd, Rev, Focus In/Out, On/Off (Quantity: 4-11) Fwd, Rev, Focus In/Out, On/Off (Quantity: 12+) MX Dual Projector Controller
1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year 1 Year
US US US US US US US US US US US US
Fwd, Rev, Focus In/Out, On/Off, Dual Fwd, Dual Rev - 2 Projectors Transmitters Only

MX12TX

12 Buttons, 12 Functions MX Accessories
MX-PS MX8 MX16 MX8-IRX MX16-IRX
Power Supply 13.5 VAC 520 mA (for MX2 and MX4 series) RF Relay Receiver, 8 Relays (includes TXC16+ and power supply-MX-PS) RF Relay Receiver, 16 Relays (includes TXC16+) (includes TXC16+ and power supply - MX-PS) IR Relay Receiver, 8 Relays (includes TXC16+, IRX-DM+ and power supply - MX-PS) IR Relay Receiver, 16 Relays (includes TXC16+, IRX-DM+ and power supply - MXPS) PC Presenter - Controllers

doc1

62-2019.fm Page 1 Friday, April 15, 2011 8:31 AM
TB7200 Series Communicating Zone Thermostats
INSTALLATION INSTRUCTIONS

APPLICATION

The TB7200 Series PI thermostat family is specifically designed for zoning applications. The TB7200 Series are communicating thermostats with models available in BACnet MS/TP and ZigBee wireless mesh protocols and can be easily integrated into a WEBs-AX building automation system based on the NiagaraAX platform. Typical applications include local hydronic reheat valve control and pressure dependent VAV with or without local reheat. Accurate temperature control is achieved due to the products PI proportional control algorithm, which virtually eliminates temperature offset associated with traditional, differential-based thermostats. Models are available for 3 point floating and analog 0 to 10 Vdc control. In addition remote room sensing is available.

TB7200 Series Thermostat

Thermostats equipped with an occupancy sensor cover provide advanced active occupancy logic, which will automatically switch occupancy levels from Occupied to Stand-By and Unoccupied as required by local activity being present or not. This advanced occupancy functionality provides advantageous energy savings during occupied hours without sacrificing occupant comfort. All thermostats are PIR ready and can be ordered with or without Honeywell occupancy sensor. The occupancy sensor cover is available to order separately if a PIR is needed at a later time.
TB7200 Series Thermostat with Occupancy Sensor

FEATURES

Available in BACnet MS/TP and ZigBee wireless protocols Backlit LCD display with dedicated function menu keys for simple operation Fully integrated advanced occupancy functionality with a PIR cover provides energy savings opportunity on select models; all other models are PIR ready and can have an optional occupancy sensor cover added at any time Pre-configured sequences of operation means one model meets more application needs Password protection to minimize parameter tampering Four levels of keypad lockout to limit access to change user parameters such as setpoints, system mode, etc. Available in 24 Vac on/off, floating or 0-10 Vdc analog control to meet advanced applications requirements Three configurable inputs for monitoring and advanced functions SPST auxiliary output that can be used for lighting or reheat All wiring connections are made to removable terminal blocks simplifying installation

62-201901

62-2019.fm Page 2 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS
TB7200 Series Model Selection
Product Number BACnet Models TB7200C5014B TB7200C5514B TB7200F5014B TB7200F5514B Wireless Models TB7200C5014W TB7200C5514W TB7200F5014W TB7200F5514W Accessories TB-CHGOVR-1014 TB-DUCT-1014 TB-MA-1014 TB-ODA-1014 TB-PIR-ZN TB-RA-1014 TB-RP5000W Changeover Sensor 10K NTC Type 2 Duct Sensor 10K NTC Type 2 Mixed Air Sensor 10K NTC Type 2 Outdoor Air Sensor 10K NTC Type 2 Zone Occupancy Sensor Cover Wireless Remote Antenna Base Wireless Repeater for TB7XXX Series Wireless Thermostats Room Sensor 10K NTC Type 2 Modulating with Reheat Modulating with Reheat Modulating with Reheat Modulating with Reheat 2 floating or on/off + 1 Aux 2 floating or on/off + 1 Aux 2 0-10Vdc + 1 Aux 2 0-10Vdc + 1 Aux Ready Yes Ready Yes Modulating with Reheat Modulating with Reheat Modulating with Reheat Modulating with Reheat 2 floating or on/off + 1 Aux 2 floating or on/off + 1 Aux 2 0-10Vdc + 1 Aux 2 0-10Vdc + 1 Aux Ready Yes Ready Yes Description Outputs Occupancy Sensor1

TB-VWG-APP-1014 TB7XXX Series Wireless Communication Card TB-WALL-1014 TB-WALLOVR-1014 Room Sensor with Override 10K NTC Type Thermostats ordered without an occupancy sensor cover can be retrofitted with the cover at a later time if required

More Information

We recommend downloading the appropriate integration reference document (wireless or BACnet) and if installing thermostats with occupancy sensor covers, then also downloading the PIR Application Guide before you begin installation. All documentation is available on http://customer.honeywell.com. BACnet Integration Manual for TB7200 and TB7300 Series Thermostats (Form No. 63-4524) Wireless Installation & Integration Reference Guide for TB7200, TB7300, and TB7600 Thermostats (Form No. 63-4522) PIR Application Guide for TB7200 and TB7300 Thermostats (Form number 63-4526)

INSTALLATION AND WIRING

Mounting Location
Do not install on an outside wall Must be installed away from any heat source Should not be installed near an air discharge grill Should not be mounted in direct sun light Nothing must restrain vertical air circulation to the thermostat Wall surface must be flat and clean
IMPORTANT If replacing an old thermostat, label the wires before removal of the old thermostat.
62-2019.fm Page 3 Friday, April 15, 2011 8:31 AM

CAUTION

Electronic controls are static sensitive devices. Discharge yourself properly before manipulation and installing the thermostat. Short circuit or wrong wiring may permanently damage the thermostat or the equipment. Anti-short cycling can be set to 0 minutes for equipment that has an anti cycling timer. Do not set to 0 unless the equipment has internal anti-cycling timer or damage to equipment can occur. All TB7200 series thermostats are to be used only as operating controls. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user to add safety devices and/or alarm system to protect against such catastrophic failures.

Thermostat Installation

1. 2. 3. 4. 5. Open up by pulling on the bottom side of thermostat. (Fig. 1) Remove wiring terminals. Open the thermostat PCB to the left by pressing the PCB retaining tabs. (Fig. 2) Pull cables 6 inches out of the wall.

Thread cable through the central hole of the base.

M21300

Fig. 1. Remove cover of thermostat 6. 7. 8. Align the base and mark the location of the two mounting holes on the wall. Install proper side of base up. Install anchors in the wall. Insert screws through the mounting holes on each side of the base and mount base on wall. (Fig. 2).

PCB RETAINING TABS

Gently swing back the circuit board back to the base and push on it until the tabs lock it in place.

M21301

Strip each wire 1/4 inch.

11. 12. 13. 14. 15.

Wire the terminals for the desired application. See Table 1 for terminal descriptions and wiring diagrams. Gently push back excess cable into hole. Install wiring terminals in correct location (Fig. 3). Reinstall the cover (top first). Install security screw.
Fig. 2. Location of PCB retaining tabs and mounting screws
TOP LEFT 5 POLE CONNECTOR TOP RIGHT 3 POLE CONNECTOR

BOTTOM 8 POLE CONNECTOR

M21302
Fig. 3. Re-install terminal blocks
62-2019.fm Page 4 Friday, April 15, 2011 8:31 AM

Thermostat Terminals

Table 1. Terminal identification TB7200C5x14(x) 1 or 2 floating outputs 1 or 2 on/off outputs 24 V~ Hot 24 V~ Com BO 5-Aux BO 5-Aux BO 3 BO 4 BO 1 BO 2 BI 1 RS Scom BI 2 UI 3 9- AO 2 Heat 10- AO 1 Cool Not used Blank 12- BI 1 13- RS 14- Scom 15- BI 2 16- UI 3 COS/COC /SS AO 2 AO 1 Blank BI 1 RS Scom BI 2 UI 3 TB7200F5x14(x) 1 or 2 analog outputs 24 V~ Hot 24 V~ Com BO 5-Aux BO 5-Aux
Terminal Description 4- 24 V~ Hot 5- 0 V~ Com 6- Aux BO 5 7- Aux BO 5 8- BO 3 Open Heat 9- BO 4 Close Heat 10- BO 1 Open Cool 11- BO 2 Close Cool 12- BI 1 13- RS 14- Scom 15- BI 2 16- UI 3 COS/COC /SS
Terminal Description 4- 24 V~ Hot 5- 0 V~ Com 6- Aux BO 5 7- Aux BO 5
For information on configuration options for the binary inputs (B1 and B2) and the universal input (U3) see Table 8. Configuration Parameters.
Sensor Wiring for all Thermostat Models
Remote mount temperature sensors use 10K NTC thermistor. A remote sensor can be used for: Various averaging combinations Optional occupancy led Optional override key Table 2. Temperature vs. Resistance chart for 10 Kohm NTC thermistor (R25C = 10K3%, B25/85C = 3975K1.5%) C -40 -35 -30 -25 F -40 -31 -22 -13 Kohm 324.3197 234.4009 171.3474 126.6109 C -20 -15 -10 -14 23
BI 1 RS Scom BI 2 UI 3 CONTACT DOOR REMOTE OVERRIDE FILTER ALARM SERVICE ALARM REMOTE WALL SENSOR
Kohm 94.5149 71.2430 54.1988 41.5

F 50 59

Kohm 32.1910 25.1119 19.7390 15.6286

C 30 35

F 86 95
Kohm 12.4601 10.0000 8.0694 6.5499

C 50 55

Kohm 4.3881

104 5.3.3.0016

CONTACT REM NSB MOTION WINDOW
SS (SUPPLY SENSOR) COS (CHANGEOVER SENSOR)
OR COC/NH NORMALLY HEAT CLOSED CONTACT = COLD WATER COC/NC NORMALLY COOL CLOSED CONTACT = HEAT WATER

M16948

Fig. 4. Remote Inputs
62-2019.fm Page 5 Friday, April 15, 2011 8:31 AM
REMOTE WIRING 1 SENSOR TB7200 SERIES THERMOSTAT Scom RS BO VAC COM BI 2 S2
TB-WALLOVR-1014 Scom RS AUX C DI DIP SWITCHES S2 = ON S3 = ON
TB7200 SERIES THERMOSTAT Scom RS BO VAC COM BI 2 S2
TB-WALL-1014 Scom RS DIP SWITCHES S2 = ON S3 = ON
DIP SWITCHES S2-1 = ON S2-2 = ON

M16991

Fig. 5. Wiring example of single remote wall mounted room sensor
REMOTE WIRING 2 SENSORS 1 TB7200 SERIES TB-WALLOVR-1014 TB-WALL-1014 THERMOSTAT Scom RS RS BO VAC COM BI 2 S2
TB7200 SERIES TB-WALLOVR-1014 TB-WALLOVR-1014 THERMOSTAT Scom RS RS BO VAC COM BI 2 S2
TB7200 SERIES THERMOSTAT Scom
TB-WALL-1014 TB-WALL-1014 Scom RS RS DIP SWITCHES S2 = ON S3 = OFF
Scom RS DIP SWITCHES S1 = ON S2 = OFF

Scom RS AUX C DI

Scom RS BO VAC COM BI 2
AUX C DI DIP SWITCHES S1 = ON S2 = OFF

AUX C DI

DIP SWITCHES S2 = ON S3 = OFF
DIP SWITCHES S2-1 = OFF S2-2 = ON 1
DIP SWITCHES S2-1 = OFF S2-2 = ON TB-WAL-1014 AND TB-WALLOVR-1014 CAN BE MIXED AND MATCHED TB-WAL-1014 AND TB-WALLOVR-1014 ARE TO BE WIRED IN PARALLELL ENSURE THE DIP SWITCH SETTING IS CORRECT IN EACH REMOTE SENSOR
DIP SWITCHES S2-1 = OFF S2-2 = ON

M16992

Fig. 6. Wiring examples of two remote wall mounted room sensors for averaging applications
REMOTE WIRING 3 SENSORS TB7200 SERIES THERMOSTAT Scom RS RS BO VAC COM BI 2 S2

TB-WALLOVR-1014 Scom

TB-WALL-1014 Scom

TB-WALL-1014 Scom RS

TB-WALL-1014
Scom RS BO VAC COM BI 2 RS
Scom RS DIP SWITCHES S2 = OFF S3 = OFF
RS DIP SWITCHES S2 = OFF S3 = OFF
AUX C DI DIP SWITCHES S2 = OFF S3 = OFF
DIP SWITCHES S2-1 = OFF S2-2 = OFF

M16993

Fig. 7. Wiring examples of three remote wall mounted room sensors for averaging applications
62-2019.fm Page 6 Friday, April 15, 2011 8:31 AM

Wiring Auxiliary Inputs

DRY CONTACT TO END DEVICE 24 V~ MAXIMUM #V~ HOT #V~ COM #6 #VAC POWER TO RELAY #V~ HOT #V~ COM #6 #7

M16949

Fig. 8. Auxiliary Inputs
Wiring for Typical Valve Applications
Single output applications Dual output applications

24 V~ HOT 24 V ~ COM

24 VAC COM
On-Off control TB7200C5x14(x)

24 V~ HOT 24 V ~ COM BO1 BO2

IF N.O. OR IF N.C.

HEATING/COOLING VALVE

BO3 BO4 BO1 BO2

IF N.O. OR IF N.C. IF N.O. OR IF N.C.

HEATING VALVE

M16917

COOLING VALVE

Floating control TB7200C5x14(x)
OPEN COM CLOSE HEATING/COOLING VALVE

M16925

24 V~ HOT 24 V ~ COM BO3 BO4 BO1 BO2
OPEN COM CLOSE OPEN COM CLOSE HEATING VALVE

M16918

Analog control TB7200F5x14(x)
COM 24 VAC 0-10 VDC HEATING/COOLING VALVE

M16926

24 V~ HOT 24 V ~ COM AO 2
COM 24 VAC 0-10 VDC COM 24 VAC 0-10 VDC HEATING VALVE

M16919

62-2019.fm Page 7 Friday, April 15, 2011 8:31 AM
Wiring for Typical Actuator Applications
Schematic Modulating floating VAV Actuator
UI 3 COS 0 V~ COM 24 V ~ HOT BO 1 OPEN BO 2 CLOSE

Wiring

Settings Mandatory Out1Conf = 2.0 CntrltTyp = Floating FL time = as per actuator SeqOpera = 0 Cooling only
Pressure dependent VAV cooling only: TB7200C5x14(x) floating actuator

OVERRIDE

ROOM TEMPERATURE CONTROL MINIMUM AND MAXIMUM POSITION ADJUSTED ON THE ACTUATOR

M16965

M16972
Pressure dependent VAV cooling only: TB7200F5x14(x) analog actuator Analog VAV Actuator
UI 3 COS 0 V~ COM 24 V ~ HOT AO 1
Mandatory Out1Conf = 2.0 RA/DA = as per actuator SeqOpera = 0 Cooling only

0 TO 10 VDC

M16973
Pressure dependent VAV cooling/heating with changeover: TB7200C5x14(x) floating actuator Modulating floating VAV Actuator

CHANGEOVER SENSOR

Mandatory Out1Conf = 2.0 CntrltTyp = Floating FL time = as per actuator If heat/cool auto-changeover with a local discharge air temperature sensor set: SeqOpera = 0 Cooling only UI3 = COS

M16966

SUPPLY AIR TEMPERATURE SENSOR

M16974

Pressure dependent VAV cooling/heating with changeover: TB7200F5x14(x) analog actuator 0 to 10 Vdc analog Actuator Mandatory Out1Conf = 2.0 RA/DA = as per actuator UI 3 COS CHANGEOVER

SENSOR

0 V~ COM 24 V ~ HOT AO 1
If heat/cool auto-changeover with a local discharge air temperature sensor set: SeqOpera = 0 Cooling only UI3 = COS

M16975

62-2019.fm Page 8 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Schematic Wiring Settings
Pressure dependent VAV cooling/heating with changeover and reheat: TB7200C5x14(x) floating actuator Modulating floating VAV Actuator Mandatory BO 5-AUX Out1Conf = 2.0 BO 5-AUX CntrltTyp = Floating CHANGEOVER FL time = as per actuator SENSOR UI 3 COS

0 V~ COM

HEATING AND/OR COOLING AND ON/OFF DUCT HEATER
24 V ~ HOT BO 1 OPEN BO 2 CLOSE
If heat/cool auto-changeover with a local discharge air temperature sensor set: SeqOpera = 2 Cooling with Reheat UI3 = COS

M16967

M16976
Pressure dependent VAV cooling/heating with changeover and reheat: TB7200F5x14(x) analog actuator Analog VAV Actuator Mandatory BO 5-AUX Out1Conf = 2.0 BO 5-AUX RA/DA = as per actuator CHANGEOVER
UI 3 COS 0 V~ COM 24 V ~ HOT AO 1 AO 2

M16979

Heating or cooling hydronic valve control: TB7200C5x14(x) floating actuator Modulating floating Valve
Mandatory Out1Conf = 2.0 CntrltTyp = Floating FL time = as per actuator If cooling only set: SeqOpera = 0 Cooling only If heating only set: SeqOpera = 1 Heating only

HEATING OR COOLING VALVE

ROOM TEMPERATURE CONTROL THERMOSTAT

M16968

M16977
Heating or cooling hydronic valve control: TB7200F5x14(x) analog actuator Analog valve
Mandatory Out1Conf = 2.0 RA/DA = as per actuator If cooling only set: SeqOpera = 0 Cooling only
If heating only set: SeqOpera = 1 Heating only

M16978

62-2019.fm Page 9 Friday, April 15, 2011 8:31 AM
Cooling/heating with changeover hydronic valve control: TB7200C5x14(x) floating actuator Modulating floating Valve Mandatory UI 3 COS Out1Conf = 2.0 CntrltTyp = Floating 0 V~ COM FL time = as per actuator 24 V ~ HOT

BO 1 OPEN

OPTIONAL WATER SUPPLY SENSOR HEATING AND/OR COOLING VALVE

BO 2 CLOSE

If heat/cool auto-changeover with a local water temperature sensor set: SeqOpera = 0 Cooling only UI3 = COS

M16969

M16980
Cooling/heating with changeover hydronic valve control: TB7200F5x14(x) analog actuator Analog Valve Mandatory Out1Conf = 2.0 UI 3 COS RA/DA = as per actuator 0 V~ COM

24 V ~ HOT AO 1

M16981
THERMOSTAT USER INTERFACE
The thermostat features a two-line, eight-character display. There is a low level backlight level that is always active and can only be seen at night. To turn on the back light to high level, press any key on the front panel. The back lit display will return to low level when the thermostat is left unattended for 45 seconds. When left unattended, the thermostat has an auto scrolling display that shows the actual status of the system. Use the MenuScro in the configuration menu to lockout the scrolling display and to only present the room temperature and conditional outdoor temperature to the user. With this option enabled, no local status is given on the system mode or occupancy. Each item is scrolled one by one with the back lighting in low level mode. Pressing any key will cause the back light to come on to high level. When left unattended for 10 seconds after changes are made, the display will resume automatic status display scrolling. Table 3. Sequence and possible display options for the auto-scroll display Room Temp RoomTemp x.x C orF
System mode Sys mode auto Sys mode cool Sys mode heat Sys mode off
Schedule status Occupied Stand-By Unoccup Override
Outdoor Temp* Outdoor x.x C orF
Alarms Service Filter Window
* Network value only Outdoor air temperature Display is only enabled when outdoor air temperature network variable is received. Occupancy Status Occupied, Stand-By, Unoccupied and Override status are displayed on the scrolling display.
62-2019.fm Page 10 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Alarms If alarms are detected, they will automatically be displayed at the end of the status display scroll. During an alarm message display, the back lit screen will light up at the same time as the message and shut off during the rest of the status display. Two alarms maximum can appear at any given time. The priority for the alarms is as follows: Service Filter Window Indicates that there is a service alarm as per one of the programmable binary input (BI2) Indicates that the filters are dirty as per one of the programmable binary input (BI2) Indicates that the outside window or door is opened and that the thermostat has cancelled any cooling or heating action (BI1)
STATUS LEDS. Two status LEDs on the thermostat cover are used to indicate a call for heat or a call for cooling as shown in Fig. 9. Zoning models When heating and reheat is ON, the HEAT LED will illuminate. When cooling is ON, the COOL LED will illuminate.

User Control Options

Unoccupied Mode Override
An Override can be made during an unoccupied period. If the Override option is enabled in the Lockout parameter, pressing the middle override button will resume occupied setpoints for a time specified by parameter TOccTime. Table 4. Keypad interface An Override can be made during an Unoccupied period. If the Override option is enabled in the Lockout Override parameter pressing the override key will resume occupied setpoints for a time specified by parameter ToccTime Adjust the setpoints down In cooling mode only the cooling setpoint displayed, Down In heating mode only the heating setpoint displayed In auto mode (see below) Adjust the setpoints up In cooling mode only the cooling setpoint displayed, Up In heating mode only the heating setpoint displayed In auto mode (see below) Any setpoint change can be permanent or temporary based on parameter Set Type (setpoint type) Any setpoint written through the network, will be permanent and cancel any active temporary setpoints Lockouts of access to certain functions is made with the parameter (Lockout) Table 5. Occupied setpoint adjustments Auto Mode Setpoint presented to user is the setpoint from the last action taken by the thermostat or the one currently in use. Both heating and cooling setpoint are changed simultaneously while respecting the minimum configured deadband Cool XX.XF orC and Heat XX.XF orC Both heating and cooling setpoints are change simultaneously

62-2019.fm Page 12 Friday, April 15, 2011 8:31 AM
Table 8. Configuration Parameters Configuration parameters Default value PswrdSet Configuration parameters menu access password Default value = 0 Range is: 0 to 1000 Com Addr Thermostat networking address Default value = 254 Range is: 0 to 254 Significance and adjustments This parameter sets a protective access password to prevent unauthorized access to the configuration menu parameters. A default value of 0 will not prompt a password or lock the access to the configuration menu. If the thermostat is installed as a stand-alone unit, this parameter will not be used or displayed For BACnet models valid range to use is from 0 to 127. Default value of 254 disables BACnet communication for the thermostat. For wireless models valid range is 0 to 254 with a maximum of 30 thermostats per WEB-2xx controller and 50 thermostats per WEB6xx/-7xx controller. Conditional parameter to wireless models (TB7200X5x14W) This parameter will only appear on wireless thermostats. If the thermostat is BACnet, this parameter will not be used or displayed This parameter (Personal Area Network Identification) is used to link specific thermostats to a single specific WEBs controller with a wireless communication card (TB-VWG-APP-1014). For every thermostat reporting to a WEBs controller and wireless communication card (maximum of 30 thermostats per WEB-2xx controller and 50 thermostats per WEB-6xx/-7xx controller) be sure you set the SAME PAN ID value both at the wireless communication card and the thermostat(s). The default value of 0 is NOT a valid PAN ID. The valid range of available PAN ID is from 1 to 500 Conditional parameter to wireless models (TB7200X5x14W) This parameter will only appear when a wireless network adapter is present. If the thermostat is installed as a stand-alone unit or is a BACnet model, this parameter will not be used or displayed This parameter (Channel) is used to link specific thermostats to a specific WEBs controller with a wireless communication card. For every thermostat reporting to a gateway (maximum of 30 thermostats per WEB-2xx controller and 50 thermostats per WEB-6xx/-7xx controller) be sure you set the SAME channel value both at the wireless communication card and the thermostat(s). Honeywell recommends using only the channels 15 (2425 MHz) or 25 (2575 MHz). The default value of 10 is NOT a valid channel. Although the valid range of available channels is from 11 to 26 use only channel 15 or 25 to avoid interference with other wireless devices. Conditional parameter to wireless models (TB7200X5x14W) This parameter is only available for wireless thermostats. This parameter lets you to copy the configuration parameter settings from a like Honeywell TB7200 thermostat. To use this command, the thermostat you want to copy parameters from must be on the wireless network with a network address (Com addr) and must be the same model number as the thermostat you want to copy to. On the thermostat you want to copy parameters to, enter the network address (Com addr) of the thermostat you want to copy parameters from. This process can be completed locally at the thermostat or using the WEBStation-AX. If the parameters copy successfully, the Get From address returns to 255. If the parameters do not copy successfully, 254 is displayed. If the copy was not successful, verify the following: The thermostat to be copied is the same model as the one being copied to. The thermostat to be copied is on the network. The correct network address (Com addr) value for the thermostat to be copied was entered. Leaving the Get From parameter value at 255 means that configuration parameters will be set manually.

PAN ID

Personal Area Network Identification Default value = 0 Range is: 0 to 500

Channel

Channel selection Default value = 10 Set to: 15 or 25 Range is: 10 to 26

Get From

Get From another thermostat configuration utility Default value = 255 Range is: 0 to 254
62-2019.fm Page 13 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Table 8. Configuration Parameters (Continued) Configuration parameters Default value BI1 Binary input no.1 configuration Default value = None Significance and adjustments None - No function will be associated with the input Rem NSB - remote NSB timer clock input. The scheduling will now be set as per the binary input. It provides low cost setback operation via a dry contact Contact opened = Occupied Contact closed = Unoccupied Motion NO or Motion NC - Advanced PIR occupancy functions using a Normally Open (NO) or Normally Closed (NC) remote PIR motion sensor. Occupancy mode is now set as per applied PIR function and configuration. Application information is available in the PIR Application Guide for TB7200 Series Thermostats (Form No. 63-4526). This document provides installers and system designers with detailed examples on applications, parameter configuration, sequence of operations, troubleshooting and diagnostic help required for proper use of occupancy sensor models. Window EMS - Forces the system to disable any current heating or cooling action by the thermostat. The mode stays the same and the current setpoints are the same Occupied setpoints. Only the outputs are disabled. There is a Door/Window alarm displayed on the thermostat to indicate to the local tenant that the door/window needs to be closed for cooling or heating to resume. NOTE: These settings will disable the local override function on the thermostat. (None): No function will be associated with the input (Door Dry) Door contact and Motion detector: This configuration is only functional if binary input #1 is set to Motion N.O. or Motion N.C. or a PIR accessory cover is used. With this sequence enabled, the occupancy is now dictated through those 2 inputs. Any motion detected will set the zone to occupied status. The zone will remain permanently in occupied mode until the door contact switch opens momentarily. The thermostat will then go in stand-by mode. If more movements are detected, the occupied mode will resume. While the door is opened, any movements detected by the remote PIR sensor or the PIR accessory cover will be ignored. Use a Normally Closed contact switching device. Contact opened = Door opened Contact closed = Door closed (RemOVR): temporary occupancy remote override contact. This function disables the central button override function on the thermostat. The override function is now controlled by a manual remote momentarily closed contact. When configured in this mode, the input operates in a toggle mode. It is now possible to toggle between unoccupied and occupied setpoints for the amount of time set by parameter (TOccTime) temporary occupancy time. (Filter): a backlit flashing Filter alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied to a differential pressure switch that monitor filters Contact opened = No alarm Contact closed = Alarm displayed (Service): a backlit flashing Service alarm will be displayed on the thermostat LCD screen when the input is energized. It can be tied in to the AC unit control card, which provides an alarm in case of malfunction. Contact opened = No alarm Contact closed = Alarm displayed

Output # 1 configuration Default value = 4.0 (2 control outputs, no changeover)

CntrlTyp

Control type for Triac models Default value = Floating
62-2019.fm Page 15 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Table 8. Configuration Parameters (Continued) Configuration parameters Default value SeqOpera Sequence of operation Default value = Sequence #1 Significance and adjustments See Table 10 for SeqOpera level details
Sequence 0 = Cooling Only 1 = Heating only 2 = Cooling with Reheat 3 = Heating with Reheat 4 = Cool and Heat, 2 outputs
Table 10. Sequence of Operation Single output application (Out1Conf) = 2.0) Yes access Yes access Yes access Yes access No access
Dual output application (Out1Conf) = 4.0) Yes access Yes access Yes access Yes access Yes access
5 = Cool and Heat, 2 outputs with Reheat No access Yes access For single output applications, the system access is also limited if UI3 is configured for local changeover COS, COC/NC or COC/NC. St-By TM Stand-by Timer value Default = 0.5 hours Time delay between the moment where the PIR cover detected the last movement in the area and the time which the thermostat stand-by mode and setpoints become active. Range is: 0.5 to 24.0 hours in 0.5 hr increments Time delay between the moment where the thermostat toggles to stand-by mode and the time which the thermostat unoccupied mode and setpoints become active. The factory value or 0.0 hours: Setting this parameter to its default value of 0.0 hours disables the unoccupied timer. This prevents the thermostat from drifting from stand-by mode to unoccupied mode when PIR functions are used Range is: 0.0 to 24.0 hours in 0.5 hr increments The value of this parameter should reside between the occupied and unoccupied heating setpoints. Ensure that the difference between the stand-by and occupied value can be recovered in a timely fashion when movement is detected in the zone. Stand-by heating setpoint range is: 40 to 90 F (4.5 to 32.0 C) The value of this parameter should reside between the occupied and unoccupied cooling setpoints. Ensure that the difference between the stand-by and occupied value can be recovered in a timely fashion when movement is detected in the zone. Stand-by cooling setpoint range is: 54 to 100 F (12.0 to 37.5 C) Heating setpoint range is: 40 to 90 F (4.5 to 32.0 C) Cooling setpoint range is: 54 to 100 F (12.0 to 37.5 C)

Unocc TM

Unoccupied Timer value Default = 0.0 hours

St-By HT

Stand-by heating setpoint Default value = 69 F

St-By CL

Stand-by cooling setpoint limit Default value = 78 F

Unocc HT Unocc CL

Heat max Cool min
Unoccupied heating setpoint Default value = 62 F Unoccupied cooling setpoint limit Default value = 80 F Maximum heating setpoint limit Default value = 90 F (32 C) Minimum cooling setpoint limit Default value = 54 F (12 C)

Maximum occupied and unoccupied heating setpoint adjustment. Heating setpoint range is: 40 to 90 F (4.5 to 32.0 C) Minimum occupied and unoccupied cooling setpoint adjustment. Cooling setpoint range is: 54 to 100 F (12.0 to 37.5 C)
62-2019.fm Page 16 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Table 8. Configuration Parameters (Continued) Configuration parameters Default value Pband Proportional band setting Default value = 3 Significance and adjustments Adjust the proportional band used by the thermostat PI control loop.
Note that the default value of 3.0 F (1.2 C) gives satisfactory operation in most normal installation cases. The use of a superior proportional band different than the factory one is normally warranted in applications where the thermostat location is problematic and leads to unwanted cycling of the unit. A typical example is a wall mounted unit where the thermostat is installed between the return and supply air feeds and is directly influenced by the supply air stream of the unit.
Value Set Type Temporary setpoint enable Default value = Permnent Enables temporary setpoints feature to any change of occupied or unoccupied setpoint.
F scale P band C scale P band 3F 4F 5F 6F 7F 8F 9F 10 F 1.7 C 2.2 C 2.8 C 3.3 C 3.9 C 4.4 C 5.0 C 5.6 C

TOccTime

Temporary occupancy time Default value = 2 hours

Deadband

Minimum deadband Default value = 2.0 F (1.0 C)

Cal RS

Room air temperature sensor calibration Default value = 0.0 F or C
Temporar: (temporary) Local changes to the heating or cooling setpoints by the user are temporary. They will remain effective for the duration specified in the parameter ToccTime. Setpoints will revert back to their default value after internal timer ToccTime expires. To change setpoints permanently, revert parameter to No or write setpoints through the network. Any setpoints written through the network will be permanent ones and saved to EEPROM. Permnent: (permanent) Any change of occupied or unoccupied setpoints through the keypad by the user are permanent and saved to and EEPROM Temporary occupancy time with occupied mode setpoints when override function is enabled When the thermostat is in unoccupied mode, function is enabled with either the menu or BI1 or BI2 configured as remote override input. 0,1, 2, 3, 4, 5, 6, 7, 8, 9, 10, and up to 24 hours Minimum deadband value between the heating and cooling setpoints. If modified, it will be applied only when any of the setpoints are modified. 2, 3, 4 or 5 F, 1.0 F increments (1.0 to 2.5 C, 0.5 C increments) Offset that can be added/subtracted to actual displayed room temperature 5.0 F, 1.0 F increments ( 2.5 C, 0.5 C increments)

62-2019.fm Page 17 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Table 8. Configuration Parameters (Continued) Configuration parameters Default value Aux cont Auxiliary contact function and configuration Default value = 0 Not Used Significance and adjustments 0 Aux contact function used for reheat. IF SEQUENCE IS SET TO REHEAT THROUGH NETWORK OR LOCAL, Ignore this parameter. The output will directly follow the occupancy of the thermostat 1 Auxiliary NO, Occ or St-By = Contact Closed/Unoccupied = Contact Opened 2 Auxiliary NC, Occ or St-By = Contact Opened/Unoccupied = Contact Closed Output to follow directly main occupancy and Fan on command Typically used for 2 position fresh air damper applications. 3 Auxiliary NO, Occ or St-By and Fan On = Contact Closed/ Unoccupied and Fan On or Off = Contact Opened 4 Auxiliary NC, Occ or St-By and Fan On = Contact Opened/ Unoccupied and Fan On or Off = Contact Closed Output to follow secondary network occupancy command 5 Auxiliary on/off control through auxiliary network command. The output can be commanded through the network for any required auxiliary functions through a separate and dedicated network variable. Floating actuator timing TB7200C5x14(x) models only Default value = 1.5 minutes Maximum stroke time of floating valve actuator. 0.5 to 9.0 in 0.5 minutes increment On/Off devices cycles per hour TB7200C5x14(x) models only Default value = 4 cph Will set the maximum number cycles per hour under normal control operation. It represents the maximum number of cycles that the equipment will turn ON and OFF in one hour. Note that a higher cph will represent a higher accuracy of control at the expense of wearing mechanical components faster. 3, 4, 5, 6,7 and 8 cph Reverse acting or Direct acting TB72xxF5x14(x) models only signal for analog output signals Changes the action of the analog outputs on the analog models. Default value = DA signal DA = Direct acting - 0 to 100 % = 0 to 10 Vdc RA = Reverse acting - 0 to 10 % - 10 to 0 Vdc Sets the time base for the Sets the reheat output time base reheat output if used Valid only if reheat sequences are enabled Default value = 0= 15 minute 0 = 15 minutes 1 = 10 seconds for Solid state relays Display supply or changeover Used as diagnostic/service help to troubleshoot and diagnose sensor temperature operation Only when UI 3 is configured as an analog input (SS or COS)

FL time

Reheat

UI3 dis

62-2019.fm Page 18 Friday, April 15, 2011 8:31 AM

SPECIFICATIONS

Network Protocol: Models available in BACnet MS/TP or ZigBee wireless mesh WEBs-AX Controllers: Compatible with WEB-2xx, WEB-6xx, and WEB-7xx Platform: WEB-2xx and WEB-6xx - WEBStation-AX 3.0 or later WEB-7xx - WEBStation-AX 3.5 or later Thermostat power requirements: 19-30 Vac 50 or 60 Hz; 2 VA Class 2 Operating conditions: 32 F to 122 F (0 C to 50 C) 0% to 95% R.H. non-condensing Storage conditions: -22 F to 122 F (-30 C to 50 C) 0% to 95% R.H. non-condensing Temperature sensor: 10 K NTC thermistor on board Temperate sensor resolution: 0.2 F ( 0.1 C) Temperature control accuracy: 0.9 F ( 0.5 C) @ 70 F (21 C) typical calibrated Remote Sensor Input: 10K NTC Occ. Stand-By and Unocc cooling setpoint range: 54 to 100 F (12.0 to 37.5 C) Occ. Stand-By and Unocc heating setpoint range: 40 F to 90 F (4.5 C to 32 C) Room and outdoor air temperature display range -40 F to 122 F (-40 C to 50 C) Proportional band for room temperature control: Cooling and Heating: 3.2 F (1.8 C) Binary inputs: Dry contact across terminal BI1, BI2 and UI3 to Scom Contact output rating: Triac output: 30 Vac, 1 Amp. Maximum, 3 Amp in-rush Analog: 0 to 10 Vdc into 2K resistance min. Wire gauge 18 gauge maximum, 22 gauge recommended Dimensions: See Fig. 10

5 (125)

3-2/5 (86)

1-3/20 (29)

M16970
Fig. 10. Thermostat dimensions in inches (mm) Approximate shipping weight: 0.75 lb (0.34 kg)
62-2019.fm Page 19 Friday, April 15, 2011 8:31 AM
TB7200 SERIES COMMUNICATING ZONE THERMOSTATS Agency Approvals all models: UL: UL 873 (US) and CSA C22.2 No. 24 (Canada), File E27734 with CCN XAPX (US) and XAPX7 (Canada) Industry Canada: ICES-003 (Canada) Agency Approvals all models FCC: Compliant to CFR 47, Part 15, Subpart B, Class A (US) CE: EMC Directive 89/336/EEC (Europe Union) Agency Approvals wireless models FCC: Compliant to: Part 15, Subpart C This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT All TB7200 series controls are for use as operating controls only and are not safety devices. These instruments have undergone rigorous tests and verifications prior to shipment to ensure proper and reliable operation in the field. Whenever a control failure could lead to personal injury and/or loss of property, it becomes the responsibility of the user/installer/electrical system designer to incorporate safety devices (such as relays, flow switch, thermal protections, etc.) and/or alarm system to protect the entire system against such catastrophic failures. Tampering of the devices or miss application of the device will void warranty.

 

Tags

W6000 DMC-ZX1 WD-80290NP KL-60 Pluriel CM600S WTA 26 Agoris 4660 18-25 Asus P2B AQ12FAN Serie Amplifier F-V310 AW1212AA Deskjet 3645 37LG30 NAD S300 FO-1470 KX-TG6413 DS-2090 KV-29RE10K TC ESC F700B DRA-700AE PPF271 07B DMC-F7 C109STF CDX-596 LDS4821ST Uk AVR-3300 MC-100 AX-870 X193W Photosmart 8230 VGN-P11z W MHC-GRX5 PT-LB75NTU Satellite HT-P50 MM008V2 Quattro P4I65GV BC-60 WL-303 DVP-S570D NAD C352 LP820 SX420W 7130C SGH-B300S HT-BD8200 Vostro A860 265-1 DI9532 DSR3016 MS2647GR Coupe KX-TC1743W CPC800 MRX-100 Switcher PB1000 KRC-V679R NV-VJ82PN VKC902HTM RQ1050 15 HR-S7722 HB175 300 AE KX-TG6423E DTH6300F Nubira GT-10000 Little Disk SBG1000 HB-152CE NP-HBC10 CT-333 RDR-HX785 M2094D-PZ White Review AT7313 K2927EZ IDE 1000 PM3500 DVD755VR C6112 Finepix 50I Tapco S8 Omni-400 Gpsmap 62 Desktop S510 P4BGL-MX RS 140 2 Plus W5-W7 Incredible Asus P2LB

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101