AMX Radia Lighting Control System Controllermodulescards
|
|
Bookmark AMX Radia Lighting Control System Controllermodulescards |
About AMX Radia Lighting Control System Controllermodulescards Here you can find all about AMX Radia Lighting Control System Controllermodulescards like manual and other informations. For example: review.
AMX Radia Lighting Control System Controllermodulescards manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a AMX Radia Lighting Control System Controllermodulescards please write about it to help other people. [ Report abuse or wrong photo | Share your AMX Radia Lighting Control System Controllermodulescards photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)AMX Radia Lighting Control System (controllermodulescards), size: 1.1 MB |
AMX Radia Lighting Control System Controllermodulescards
User reviews and opinions
| clo |
5:18pm on Sunday, March 14th, 2010 ![]() |
| jensen jta 220 please forgive my spelling, i love this product. the speakers built into the unit are not very good. JENSEN...good brand, good machine This little guy is just what I was looking for. VERY happy with it. Good sound. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

Installation Guide
RE-DM4 Radia Eclipse 4-Channel Dimmer Module (120 or 240 volts)
Overview
The RE-DM4 RADIA Eclipse 4-Channel Integrated Dimmer Module (120 VAC: FG706-01; 240 VAC: FG706-02) controls up to six circuits with four 1200-watt onboard dimmers and two satellite connectors for RDM series dimmer or switch modules (FIG. 1). The RE-DM4 is designed for use with the RDA series of enclosures in an AMX Lighting modular digital dimming system. The RE-DM4 is controlled by AXLink or by dry (contact) closures. Mounting points Power Devices Jumper High Voltage Connections Load out Chokes Class 1 wiring
RE-DM4 Specifications (Cont.)
Idle current draw RDM control current Certifications 75 mA @ 120 VAC, 50 mA @ 240 VAC, 100 mA @ 13.5 VDC 2 at 200 mA @ 12 VDC with no additional power supply FCC CE UL North America IEC-60950 Safety
Line In Neutral
Operating Temp Range Included Accessories Required Enclosures
0 to 40C (32 to 104F) 2 4-pin 3.5mm captive wire connector (41-5047) 4 #8-32x1/2 F-point mounting screws RDA-ENC2 (FG606-10) RDA-ENC4 (FG606-11) RDA-ENC6/6B (FG606-12/13/15) RDA-ENC12B (FG606-14/16)
Suggested Loads Dimmed
Incandescent Neon, cold-cathode
Switched
Motors Fans
Caution: Pre-Installation Notes
Class 2 wiring WARNING: This unit should be installed only by qualified electrical personnel, and in compliance with all national electrical codes, local codes and ordinances.To prevent possible personal injury or death, disconnect power to the enclosure at the breaker box before attempting to work with any AMX Lighting modules. All Class 1 and 2 wiring must be connected to their dedicated terminals. Class 1 wiring should be connected through the top of the enclosure, and Class 2 wiring through the bottom. Load conductors must be same size as line conductors, regardless of connected load. Disconnect power while installing or connecting the unit. Keep top and bottom air vents clear at all times, and maintain 12 (30.48 cm) clearance around the top and bottom. Test loads for shorts before connecting. Class 2 wiring must be rated 300V or higher. For indoor use only. AC lighting loads only. This module may require extra power from the AXLink connection or an external power supply connected to the control card. For more information, refer to the RE-DM4 instruction manual available at www.amx.com.
AXLink Address DIP Switch Mounting points
AXlink Connector
Dry Closures
4-Pin Connectors to RDM series Modules External +12V Aux Power
FIG. 1 RE-DM4 4-Channel Integrated Dimmer Module
Specifications
RE-DM4 Specifications
Dimensions (HW) Weight Line Input 5.75" x 10.0" (146.05 mm x 254.00 mm) 4.5 lbs (2.04 kg) 120, 240 VAC, single phase, 2W+G, 50/60 Hz, 2400 W, one feed 120, 120/240, 240 VAC, single phase, 3W+G, 50/60 Hz, 4800 W, dual feed 1200 W max. per channel @120, 240 VAC 2400 W max. total, all four channels on with single 2400 W feed 4800 W max. total, all four channels on with dual 2400 W feeds Line input #1 goes to dimmer 1 and 3; line input #2 goes to dimmer 2 and 4 All electrical ratings are for continuous duty Use only copper wires rated at 75C (167F) min. To 20 in-lbs (2.3 N/M) 10 AWG (4 mm) 0.5" (13 mm) 4-pin 3.5mm black captive wire connector. AXLink communication signaling with 12VDC power in. 2-pin 3.5mm green captive wire connector. This is a 12VDC power input that supplies additional power to the Radia PCB and connected Radia modules. Emergency fire alarm relay connection - Closed relay activates preset 126. Other control is locked out until relay opens. Supports daisy chaining of up to 20 dimmers for this connection, with a maximum current requirement of 200mA when daisy-chained. Failsafe connection - Works with a toggle switch opening the switch triggers preset 128, closing the switch triggers preset 127. Supports daisy chaining of up to 20 dimmers for this connection with a maximum current requirement of 200mA when daisy-chained. 300 single feed (2400 W); 600 dual feed (4800 W)
Radia Lighting System Configuration Pages
The AMX Radia Web pages provide a simple interface for users of the Radia Duet module. The web pages reside on the AMX master when running the Radia Duet module and may be accessed through Internet Explorer or Mozilla Firefox. The REDM4 may also be configured using NetLinx code or a terminal. For more information, refer to the RE-DM4 instruction manual available at www.amx.com.
Output
High-Voltage Connections
Each AMX Lighting module has its high-voltage connectors marked on its circuit board. Line, load, and neutrals are also clearly marked. Load Line in Load Neutral
Wire rating Torque terminals Maximum wire size Wire stripping length AXLink Port Aux Power
FIG. 2 High-voltage connections
Line-in Connections
Using two feeds for Line 1 and Line 2 provides two 2400 W inputs. With a jumper, Line 1 and Line 2 provides a single 2400 W input (FIG. 3).
Dry Contacts
Dual 2400 W Inputs without jumper
Single 2400 W Input with jumper
BTU/hr
FIG. 3 Line-in Connections
Low-Voltage Connections
The low-voltage area in the AMX Lighting controllers contain connections and DIP switches for AXLink, dry closures, and RDM module connectors. On the controller cards, low-voltage power for the board is supplied either by line power, optional auxiliary power supply (RDA-PSM), or the +12 VDC pin on the AXLink connector. AXLink address DIP switch Module connector/LED (CH6) Module connector/LED (CH5)
Each dry contact closure has two pins: ground and contact. To activate each dry closure, connect the ground and contact.
Setting AXLink Address Numbers
Set the AXLink address number (1-255) for the RE-DM4. This number must match the device number in your Axcess program. Note: By turning all switches off, all circuits will go to 100 percent so that the installer can test the high-voltage connections without having connections to a control system.
Connecting AXLink
Connect the 4-pin captive-wire AXLink from the RE-DM4 to the Central Controller for AXLink control of the dimming system. AXlink connector Dry contact closures Auxiliary power IN RE-DM4 PWR AXP AXM GND PWR AXP AXM GND Central Controller
FIG. 4 Low-voltage connections and DIP switches WARNING: Disconnect the main power to the AMX Lighting controller at the breaker box if rewiring the low voltage connections.
Dry Closure Connections
Dry contact closures from other equipment can be connected to the Radia Eclipse dimmer module to provide direct manual control of lighting loads (FIG. 5). FAILSAFE GND EMERGENCY GND Failsafe switch Alarm system
FIG. 6 Connecting AXlink
RE-DM4 4-pin module connector (male)
Pin 4 (GND) Pin 3 (RLY) Pin 2 (DIM) Pin 1 (+12 V) FIG. 7 RE-DM4 module connector
RE-DM4
FIG. 5 Dry Closure Connections
Lighting Application Drawings
Example A Single input 120 or 240 VAC 1 Single-phase, four load
FIG. 8 Example A
Example B Dual Input 120, 120/240, or 240 VAC 1 Single-phase, four load
FIG. 9 Example B
For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s). 8/AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX. AMX reserves the right to alter specifications without notice at any time. 3000 RESEARCH DRIVE, RICHARDSON, TX 75082 800.222.0193 fax 469.624.7153 technical support 800.932.6993 www.amx.com
93-0706-01
REV: C
Tags
RW407 AM-619 Microondas P2411 HS740 Review DV6000 Kxtg7431 G31-M4 Mp8610 P4B266-E Digital AZ3068 DU-42PY10X SDM-S204 DI-304 MV100 Ultra Zoom Q66 EDS Spica Vivicam 3000 LM500 Samsung NV3 700 Trio KM 363 S9500 TM450 Gigaset A58H Neuf TV MC-D370 DR1F9H Lexmark C750 PX200E BFV882 Edifier X100 14 0 503CX Kxtg4022 LN40A500t1F SX-KN1400 KS-FX8R SA-XR45 RX-V1200 Receiver PS-04 PS100 A8V-XE PSC805 Minox EC Pneumatique LAV70330-W Stylus T20 XP-600 Finepix A101 SA-WX90 Roland SH09 Bonneville 1997 MO-654 GX-635 Platinum Latitude C510 Ii-platinum Hkts 2 Officejet 9110 VR702 HS06THB D KDL-40V4210 KS-FX950R CLX-6200FX XEU GCR-8521B Maxxum Qtsi IF-232C Alarms SA2 SRP-285II BG45-U-300 Super 90 Axis-1 Doro TH60 DW505 EX-Z120 SB-100 SKM 1030 BR 600 Olufsen BEO4 GI100 N1010V TSI 100 Comfort IC-M80 M-627V 630RI FAX-L360 Button CD634 AX-930 Sims 2 Laminator WD-80130F CZ02RT11P MVX35I PLC-XU70
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101