APC Back UPS Bx1300LCD
|
|
Bookmark APC Back UPS Bx1300LCD |
About APC Back UPS Bx1300LCDHere you can find all about APC Back UPS Bx1300LCD like manual and other informations. For example: review.
APC Back UPS Bx1300LCD manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a APC Back UPS Bx1300LCD please write about it to help other people. [ Report abuse or wrong photo | Share your APC Back UPS Bx1300LCD photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)APC Back UPS Bx1300LCD, size: 600 KB |
APC Back UPS Bx1300LCD
User reviews and opinions
| studiosus |
1:57pm on Saturday, October 16th, 2010 ![]() |
| Very well designed item This is a very well designed battery backup system. Call APC first before you buy! I ordered this item because the APC web site said this is the one to use for my system. | |
| billythebit |
10:53pm on Friday, August 13th, 2010 ![]() |
| Day 2: Product Worked as Hoped. No less than 24 hours after I received it and installed it, I had a power outage while I was away. battery backup and surge protector I was a little intimidated by the idea of this product but I followed the directions to get it set up and it was ea... | |
| gato2005_cl |
5:29am on Thursday, July 29th, 2010 ![]() |
| I had gotten an APC Back-UPS ES 500 a few years ago which recently had the battery go bad (they have a 3-6 year life). | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

1 CONTENTS
RJ-11 RJ-45 RJ-11 RJ-45
2 CONNECT BATTERY CARTRIDGE*
w w w.apc.com
Back UPS BR1300LCD Back-UPS BR1500LCD Back UPS BX1300LCD Back-UPS BX1500LCD Users Manual
Coax Coax
Note: This diagram is also used for battery cartridge replacement.
3 OPERATING ENVIRONMENT
4 CONNECT EQUIPMENT / POWER
CHECK BUILDING WIRING
FAULT INDICATOR
If the rear panel Building Wiring Fault (red) indicator is lit, a potential shock hazard exists due to one of the following conditions: Open or high resistance ground Hot and Neutral polarities are reversed Overloaded neutral circuit Improper building wiring should be corrected by a qualified electrician. Do not use the Back-UPS until the condition that caused the fault is corrected. Note: Improper building wiring will not prevent the BackUPS from operating, but it will limit its protection capability.
6 CONNECT MODEM/PHONE/Network
and TVSS Ground
If needed, the Back-UPS features a TVSS ground screw for connecting the ground lead of any additional stand alone surge suppression devices, such as an APC ProtectNet product; or any electronic device with an external ground connection.
8 CONNECT DATA LINE AND
INSTALL SOFTWARE ON COMPUTER (Optional)
RJ-45/ RJ-11 RJ-45/ RJ-11
From stand alone data line surge suppressor or electronic device
CABLE IN
To USB Port
CABLE OUT Building Wiring Fault
32 - 104oF (0 - 40oC)
Computer
Printer or Scanner
Phone Jack
External Disk or CD / DVD Drive Monitor
Computer Modem Port
OR Phone or Fax
CABLE IN CABLE OUT
7 CONNECT COAXIAL CABLES
Coaxial Cable
From Cable Provider To Cable Modem
1. Insert CD into computer, and on-screen instructions should appear automatically. Follow instructions to complete the installation. Note: if the on-screen instructions do not appear automatically (Autoplay is disabled), then perform steps 2 and 3 below. 2. On the computer desktop of the display, double-click on My Computer. 3. Double-click on the CD-ROM drive icon, and follow the on-screen instructions. Installation of the supplied software is the only way to take advantage of the auto shutdown capabilities that Back-UPS offers.
Follow the on-screen instructions.
To 120 VAC Wall Outlet
Building Wiring Fault
Building Wiring Fault Indicator
LCD INDICATORS and CONTROLS SUMMARY
9 SWITCH ON THE BACK-UPS
Note: Allow the Back-UPS to charge for a full 16 hours prior to using it. Press the front panel Power ON/OFF switch, and observe that the following events occur after you press and release the switch: The LCD turns on (is back lit). The ON LINE indicator flashes. The ON BATT indicator lights and flashes while a self-test is being performed. When self-test has successfully completed, only the ON LINE indicator will be lit. If the internal battery cartridge is not connected (see Step 2 above), the ON BATT indicator will flash. The Back-UPS will also emit a chirping sound.
The red, back lit liquid crystal display (LCD) on the front panel of the Back-UPS displays realtime system status messages, system faults and warnings, LOAD Capacity, and Battery Charge level. Two switches are provided on the front panel, the power ON/OFF pushbutton switch on the left, and the DISPLAY/HOLD TO MUTE pushbutton on the right.
ON LINE
DISPLAY
DISPLAY/HOLD TO MUTE button - is used to display
status messages, system faults and warnings, and to perform various operations, such as alarm mute mode, AVR (automatic voltage regulation), and full time display mode. The various messages, warnings, system faults, and operations are described in greater detail on Page 2. ON LINE - is lit whenever utility power is supplied to power the equipment connected to the Back-UPS. ON BATT - the On Battery symbol is lit whenever battery backup power is used to power equipment connected to the Back-UPS. Four Beeps Every 30 Seconds - this alarm sounds whenever the Back-UPS is running on battery (ON BATT). You should consider saving any work in progress. Continuous Beeping - this alarm sounds whenever a low battery condition occurs, and battery run-time is very low. Promptly save any work in progress, exit all open applications, and shut down the operating system, computer, Load Capacity - this indicator consists of a bar containing five blocks. When only one or two of the blocks are filled (lit), the unit LOAD is at less than half capacity.
However, when all five blocks are filled, the LOAD is at full capacity. If the LOAD exceeds the units rated capacity, the Overload symbol on the bottom of the display will flash off and on. Battery Charge - this indicator consists of a bar with five blocks. When all five blocks are filled, the battery is fully charged. When only one block is filled (lit) the battery charge is low. The word LOW and the Battery Capacity indicator bar both flash off and on. Overload - is lit whenever power demand exceeds the capacity of the Back-UPS. It is displayed in both ON LINE
mode, and ON BATT mode.
AVR When lit, it indicates automatic voltage regulation (AVR) is in Boost mode. AVR is covered in greater
LOAD Capacity
SENSITIVITY
ON BATT
detail on Page 2. System Faults - when a fault occurs, this symbol and the fault number (F01 - F09) will flash off and on. The nine fault messages are described further on Page 2. Self-Test mode - can be run at any time when in ON LINE mode. Self-test is covered in greater detail on Page 2. Mute mode - the audible alarm (beeper) can be muted (turned off), which is indicated by a line through the beeper symbol. Mute mode is covered in greater detail on Page 2. Sensitivity mode - this allows you to go into sensitivity programming mode, and using the DISPLAY button you can select the LO, MID or HIGH sensitivity range. Sensitivity mode is covered in greater detail on Page 2. Full Time Display mode - this mode allows you to set the LCD to full time display mode using the DISPLAY button. This mode is covered in greater detail on Page 2.
Reset switch - this switch is located on the rear of the Back-UPS, just above the fans, as shown in the figure in Step 4. 990-4991
ESTIMATED RUN TIME IN MINUTES
Battery Charge
IN OUT
V kW Hz
System Faults
SEE MANUAL
System Status
DISPLAY HOLD TO MUTE
Continuous tone - this alarm sounds whenever the battery backup outputs are overloaded. Overload mode is covered in greater detail on Page 2.
Replace battery - this is lit whenever the battery is near the end of its useful life, or if the battery is not connected. A battery nearing the end of its life should be replaced.
Power ON/OFF switch - is used to turn input power on and off. It is also used to initiate self-test, to go into Sensitivity mode, and it is used with the DISPLAY button to reset the Event Counter.
Chirps for 1 Minute every 5 hours - this alarm sounds whenever the battery fails the automatic diagnostic test.
ON-LINE MODE Display Selection
When you are in ON-LINE mode, and press the DISPLAY button, you will rotate through the following seven groups of displays and messages. When you press the DISPLAY button the first time, the LCD is back lit, and the input voltage (IN) default screen is displayed, in this example 110 V is displayed. When you press the DISPLAY button a second time, the power EVENT counter is displayed, as shown below. To reset the counter, press and hold the DISPLAY button, and press the power ON/OFF button.
ON-LINE MODE (Continued)
When you press the DISPLAY button a seventh time the ON BATT output (OUT) frequency is displayed, in this example it is 60.0 Hz.
BATTERY MODE (Continued)
When you press the DISPLAY button a sixth time, the battery backup LOAD is displayed as a percentage (%); in this example it is 82%.
OTHER STATUS INDICATORS
Self-Test
To initiate self-test mode, press the power ON/OFF button, and hold it in for ONE second. The AC plug symbol (ON LINE) flashes off and on during self-test mode.
Flashing
BATTERY MODE Display Selection
When you are in battery (ON BATT) mode, and press the DISPLAY button, you will rotate through the following seven groups of displays and messages.
When you press the DISPLAY button a seventh time the ONLINE output (OUT) frequency is displayed, in this example it is 60.0 Hz.
When you press the DISPLAY button the first time, the LCD is back lit, and the default screen (ESTIMATED RUN TIME IN MINUTES) is displayed, in this case it is 18 minutes.
WARNINGS
Warning 1 - Online Overload
This warning indicates that there is an ONLINE overload condition at 1.25 kW, indicated by the flashing overload icon.
When you press the DISPLAY button a second time, the power EVENT counter is displayed, as shown below. To reset the counter, press and hold the DISPLAY button, and press the power ON/OFF button.
DISPL AY
DISPLA Y
This feature allows you to mute the audible alarm (the beeper) for a single display and message. To mute the audible alarm, the unit should be on battery, or the ESTIMATED RUN TIME IN MINUTES speaker symbol is displayed. Press the DISPLAY/ HOLD TO MUTE button for ONE second, the alarm (beeper) is toggled, and the speaker-NOT symbol (speaker with a line drawn through it) is displayed on the screen. To enable an audible alarm that has been muted, perform the same steps that were used for muting the alarm. The alarm (beeper) can also be muted all the time. With the speaker or speaker-NOT icon displayed, press and hold the DISPLAY/HOLD TO MUTE button for FIVE seconds until the speaker-NOT icon flashes off and on. The unit will mute the alarm all the time except for faults.
When you press the DISPLAY button the third time, the
ESTIMATED RUN TIME IN MINUTES is displayed. In this example, the value is 18 minutes.
Warning 2 - Battery Backup Overload
This warning indicates that there is a backup battery (ONBATT) overload condition. This is indicated by the flashing overload icon.
When AVR is illuminated on the LCD, it indicates that the automatic voltage regulation (AVR) circuitry is in Boost mode. AVR compensates for excessively low voltage conditions without going on battery. In this example, 90 V is displayed.
Sensitivity
MID HIGH
A typical condition where sensitivity adjustments would be appropriate is with an AC line input, and with the UPS off. Press and hold the power ON/OFF pushbutton in for 10 seconds. The unit will go into sensitivity programming mode. Use the ON/OFF button to select the LO, MID or HIGH range. LO displays one block, MID is three blocks, and High is five blocks. Sensitivity programming mode is also discussed on Page 3.
When you press the DISPLAY button a fourth time in ON LINE mode, the LOAD in Watts (W) is displayed, in this example 760 W is displayed.
Warning 3 - Online Bad Battery
When you press the DISPLAY button a third time the battery backup (ON BATT) output (OUT) voltage (V) is displayed, in this example it is 115 V.
This warning indicates that you are in ONLINE mode, and you have a bad battery, indicated by the flashing bad battery icon.
When you press the DISPLAY button a fifth time, the online LOAD as a percentage (%) is displayed, in this example it is 82%.
Warning 4 - Battery Backup Low Battery
LCD Full Time Display Mode
LOAD LOW
When you press the DISPLAY button a fourth time the battery backup (ON BATT) input voltage (IN) is displayed.
This warning indicates that the battery is low. This is indicated by the word LOW, and the Battery Capacity indicator bar flashing.
The LCD can be set to full time display mode by performing the following steps: 1. Ensure the unit is connected to utility input power, and the power on/off switch is turned off (no power is supplied to the output connectors). 2. Press the DISPLAY/HOLD TO MUTE pushbutton, and hold it in for 10 seconds. All five blocks in the Battery Capacity bar will flash off and on, which indicates the unit is in pushbutton programming mode. Note: A rotating selection method is used that allows you to step through the display modes using the DISPLAY/HOLD TO MUTE button until you select the display mode you want. For example, in Power Save mode none of the blocks are lit. If all five of the blocks are lit, it indicates the LCD is in full time mode, and will remain on full time. 3. When you rotate through the selections and reach the display mode you want, press and release the DISPLAY/HOLD TO MUTE button to select the display mode.
Pressing the DISPLAY button a sixth time displays the ON LINE output (OUT) voltage, in this example the value is 110 V.
The first example shows an over voltage condition at 149 V. The second example shows a black out, or less than 10 Vac.
SYSTEM FAULTS
Up to nine system faults can be displayed (F01 F09). A note, SEE MANUAL, is provided just below the system fault number. The system faults include:
F01 - On-Battery Overload F02 - On-Battery Output Short F03 - On-Battery XCap Overload F04 - Clamp Short F05 - Charger Fault
When you press the DISPLAY button a fifth time the (ON BATT) input LOAD in Watts (W) is displayed, in this example 760 W is displayed.
F06 - Relay Welding F07 - Temperature F08 - Fan Fault F09 - Internal Fault
Note: If no buttons are pushed, and no operations occur for five seconds, the unit automatically exits pushbutton programming mode. 4. Once you have selected the desired display mode, continue with normal operations.
TROUBLESHOOTING
Problem
Back-UPS will not switch on.
SPECIFICATIONS
Possible Cause
Back-UPS is not connected to the AC power source. Back-UPS circuit breaker tripped.
ORDER REPLACEMENT BATTERY ORDER REPLACEMENT BATTERY
1300 VA
88 to 139 VAC +12% (Boost mode only) 57 to 63 Hz (Autosensing) Stepped Sine Wave 1300 VA: 780 W 1500 VA: 865 W 1300 VA: 16 Hours and 1500 VA: 16 Hours 32o to 104oF 0o to 40oC
Corrective Action
Ensure the Back-UPS is securely connected to an AC outlet. Disconnect non-essential equipment from the Back-UPS. Reset the circuit breaker. Switch on the Back-UPS, and plug in devices one at a time. If the circuit breaker trips again, disconnect the device that caused the breaker to trip. Connect the battery cartridge (see Connect Battery Cartridge). Consider adjusting the transfer voltage and sensitivity. See Transfer Voltage and Sensitivity Adjustment. Unplug the device from the 'Surge Only' outlet, and move to a 'Battery Backup' outlet. Verify the Back-UPS's plug is fully inserted into the wall, and power is present at the wall outlet by plugging in a known good device. No action is neccessary. Consider adjusting the transfer voltage and sensitivity. Reference Transfer Voltage and Sensitivity Adjustment. Unplug non-essential equipment (printers, scanners, etc) from the Battery Backup outlets, and plug them into 'Surge Only' outlets. Charge the battery cartridge for 16 hours. Back-UPS runtime is reduced until the battery cartridge is fully charged. Refer to Replace Battery Cartridge, and replace the battery cartridge. Refer to Replace Battery Cartridge, and replace the battery cartridge. Move one or more equipment power plugs from Battery Backup outlets to Surge Only outlets. One of nine Internal UPS Fault Messages is displayed: F01 - On-Battery Overload F06 - Relay Welding F02 - On-Battery Output Short F07 - Temperature F03 - On-Battery XCap Overload F08 - Fan Fault F04 - Clamp Short F09 - Internal Fault F05 - Charger Fault Contact APC Technical Support (see Contact Information).
On-line Input Voltage Range (default settings) Automatic Voltage Regulation (AVR) On-line Frequency Range On-battery Waveshape Maximum Load Typical Recharge Time Operating Temperature Storage Temperature
1500 VA
The battery cartridge typically lasts 3 to 6 years, a shorter period if subjected to frequent outages or elevated temperatures. For the BR1300LCD, BR1500LCD, BX1300LCD and BX1500LCD order part APCRBC109. Please recycle spent battery cartridges.
Internal battery is not connected. Utility input voltage quality is out of range. Back-UPS does not power essential equipment during an outage. Back-UPS operates on battery although utility power is provided. Equipment is plugged into a Surge Only outlet. The UPS's plug has partially pulled out of the wall outlet, the wall outlet was turned off, or its circuit breaker tripped. Unit is performing an automatic self test. Utility input voltage is out of range, frequency is out of range, or the waveform is distorted. Back-UPS does not provide expected amount of backup time. Back-UPS is overloaded. Back-UPS battery cartridge discharged due to a recent power outage, and has not had time to recharge. Battery has reached end of life. Replace Battery indicator is on. Overload indicator is on, or flashing. System Fault indicator is on and all other front panel indicators are flashing. Battery has reached end of life. Connected equipment is drawing more power than the Back-UPS can provide. Internal UPS fault.
WARRANTY
The standard warranty is three (3) years from the date of purchase. APCs standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays ground freight transportation costs to ship the replacement unit to the customer.
23o to 113oF -5o to 45oC Operating / Storage Relative Humidity 0 to 95% non-condensing Size (H x W x D) 8.7 inch x 5.1 inch x 13.8 inch 220 mm x 130 mm x 350 mm Weight 1300 VA: 29.7 lbs (13.5 kg) 1500 VA: 30.7 lbs (14.0 kg) Shipping Weight 1300 VA: 33.2 lbs (15.1 kg) 1500 VA: 34.2 lbs (15.6 kg) EMI Classification FCC / DOC Class B Certified On Battery Run-Time Go to: http://www.apc.com/product Approvals TUV C-US, NOM Notice: This device complies with Parts 68 and 15 of the FCC rules.Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. There is a label on the bottom of this equipment that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.
SERVICE
If the Back-UPS arrived damaged, notify the carrier. If the Back-UPS requires service, do not return it to the dealer. The following steps should be taken: 1. 2. 3. Consult the Troubleshooting section to eliminate common problems. If the problem persists, go to http://www.apc.com/support/. If the problem still persists, contact APC Technical Support. Have the Back-UPS model number, serial number and date of purchase available. Be prepared to troubleshoot the problem with an APC Technical Support representative. If this is not successful, APC will issue a Return Merchandise Authorization (RMA) number and a shipping address.
CONTACT INFORMATION
Technical Support Internet USA / Canada Mexico Worldwide http://www.apc.com/support http://www.apc.com 1.800.800.4272 292.0253 / 292.0255 +1.401.789.5735
LIMITED WARRANTY
TRANSFER VOLTAGE and SENSITIVITY ADJUSTMENT
In situations where the Back-UPS or connected equipment appears too sensitive to the input voltage, it may be necessary to adjust the transfer voltage. This is a simple task using the front panel power on/off pushbutton. To adjust the transfer voltage, proceed as follows: 1. Plug the Back-UPS into the utility power source, but do not turn the unit on.The Back-UPS will be in standby mode (there are no indicators lit). 2. Press and hold the front panel on/off switch in for 10 seconds, until all the indicators on the Back-UPS flash to acknowledge it has entered sensitivity programming mode. Release the on/off button, the blocks in the Back-UPS's LOAD bar shown on the LCD indicate it's current sensitivity setting, as described in the table below. Note: The Back-UPS automatically exits programming mode in five seconds if no buttons are pressed, and no operations are run. Reference the table below to determine which sensitivity setting to select. Input Voltage Range (utility operation)
4. To select the Low Sensitivity setting, press and release the ON/OFF switch several times until only the first block in the Load Bar is lit and flashing, then release the switch. 5. To select the Medium Sensitivity setting (the unit's default), press and release the ON/OFF switch until the first three blocks in the Load Bar are lit and flashing, then release the switch. 6. To select the High Sensitivity setting, press and release the ON/OFF switch until all five blocks of the Load Bar are lit and flashing, and then release the switch. 7. If there are no operations for five seconds, the Back-UPS will automatically exit sensitivity programming mode, and the Back-UPS is ready for normal operation.
Indicators Flashing 1 (one block of the Load Bar) 2 (three blocks of the Load Bar) 3 (five blocks of the Load Bar)
Sensitivity Setting Low
Use When
78 to 142 Vac Input voltage is extremely low or extremely high. Not recommended for computer loads. 88 to 139 Vac The Back-UPS frequently goes on battery (ON BATT). 88 to 136 Vac The connected equipment is sensitive to voltage fluctuations.
Medium (factory default) High
990-4991 Copyright 2006 American Power Conversion. All rights reserved. APC and Back-UPS are registered trademarks of American Power Conversion. All other trademarks are the property of their respective owners.
Tags
Twingo II MHC-ZX70DVD Central CS4 DZ9080 Ulta III MIC100 SH-E65 PS50C450b1 GT250R DVP3264 DSC-W350 P PLG100-XG PSR-84-PSR-85 Microsoft Xbox XL-E25H MV-30 110 8709 GSA-E60N KX-F250 VSX-49TX IQ820 Pocketwizard Plus 1000 E NV-RX11B Executive ABS NX9600 PDP-television DES-3828P R-852 84ST SF560R-XET S 1200 QP330 FR740-00 GR-DA20 PL607 D3450 LN40A550p3F Review LHD65ebly7 HQ6605 SC-50 IC-F5061D MZ-RH710 Armada M300 155B8BV EMP-5350 NV-HS825 UE55C9000ZW Iw G Sentra-2003 Photo 700 15HP-1998 Maker DW621 DVP-CX985V UB1204FX-PRO CDA-7876 XR-10X 11-1025 Kardon A300 Ascona Vi 245W D-E200 VPH1000Q Active Lindy VGN-N38e-W PX-AV100U FAX-phone B70 Nokia 6233 A780L3G 680 ZX DVD-SH897 300XL TSO IFP-100 KX-T7200E RX-DT75 RS 125 SGH-M300 EWF805 WF9692GQR 5000-CP Behringer C-3 WL-114V2 CT-32G12V Hdtt-5000 Thinkpad A20M Controller Compact PD726W Server 150 Impala 2003 14 0 Ed VR Livescope TX-20LA80F RX-V750 50PC3D-UE AJ3600-00C HDR-XR106E MDR-NC7 BLK
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101








1. APC BR1000G 600 Watts/1000 VA, Input 120V/Output 120V Power Saving Back UPS RS
2. APC BACK UPS XS 1300VA BX1300LCD REPLACEMENT BATTERY
3. APC 1300VA Battery Backup with LCD
4. 1300VA Bbw/LCD Retail Only
5. APC BACK UPS ES BE750G 10 Outlet 750VA 120V UPS System
6. APC Back UPS ES, 6 outlet 350VA, 120V, without auto shutdown software UPS BE350G