ARP Instruments Quartet
|
|
Bookmark ARP Instruments Quartet |
About ARP Instruments QuartetHere you can find all about ARP Instruments Quartet like manual and other informations. For example: review.
ARP Instruments Quartet manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a ARP Instruments Quartet please write about it to help other people. [ Report abuse or wrong photo | Share your ARP Instruments Quartet photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)ARP Instruments Quartet - Service Manual, size: 10.1 MB |
ARP Instruments Quartet
Video review
ARP QUARTET ANALOG SYNTHESIZER
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
INSTRUMENTS, INC.
IMPROVING QUALITY THROUGH INNOVATION:
A FULLY AUTOMATED SOLUBLE SALT METER
SSM MODEL # RPCT-07-001
For more information contact: ARP Instruments, Inc. www.arpinstruments.biz arp.instruments@gmail.com Phone: 540-752-7651 Fax: 540-752-5226
ARP Instruments, Inc. SSM White Paper-Revision 2.8 3/3/2010
Improving Quality Through Innovation: A fully automated soluble salt meter The Soluble Salt Meter (SSM) Model #RPCT-07-001 was developed specifically to improve current methods of establishing surface cleanliness for flat and curved surfaces. ARP Instruments goals in developing the SSM were to: Improve the time, quality, and accuracy in field analysis Eliminate use of syringe needles Develop a paperless instrument Automate water dosing and washing system Eliminate consumables (patches and syringes) Exactly replicate the Bresle patch protocol Eliminate residue left behind from Bresle and other adhesive patches
The SSM has been independently tested both in laboratory and Navy shipyard facilities. It is the only approved alternative by the US Navys Naval Sea Systems Command (NAVSEA) for use as a replacement to the Bresle patch method in NAVSEA Standard Item 009-32.
Background
The presence of soluble salts on a surface is detrimental to applied protective coatings. As such, the Navy has set stringent requirements for maximum allowable soluble salt concentrations for various applications. In order to test for surface cleanliness, surface contaminants must be extracted and analyzed. In the Bresle method, which is described in ISO 8502-6, a flexible cell is applied to the surface in question and injected by syringe with deionized water. Surface salts are dissolved into this solution that is removed and tested for conductivity. Conductivity measurements, recorded in microsiemens per centimeter (S/cm), correspond to the concentration of dissolved ions in the solution. A high conductivity measurement indicates a high level of dissolved ions and in turn salt contamination on the surface. ISO 8502-9 provides a method to convert conductivity measurements to equivalent concentration of NaCl. Concentration limits are used in most international shipbuilding.
The Navy has stringent requirements for conductivity measurements on prepared surfaces.
For US Navy applications, NAVSEA has specified the total number of measurements required per inspection area and the limits for individual conductivity measurements. These limits, as described in NAVSEA Process Procedure Instructions (PPI) Core 6.6.2 and NSTM 631, are as follows. Conductivity due to soluble salts shall not exceed: 30 S/cm (immersed applications) 70 S/cm (non-immersed applications) The number of measurements are: Five (5) measurements every 1,000 ft2 (90 m2) Areas less than 1000 ft2 (90 m2) shall have (5) measurements made. ARP Instruments, Inc. Automated SSM. Intelligent QA. 1
www.arpinstruments.biz
Improving Quality Through Innovation: A fully automated soluble salt meter
Current Method
The Bresle method is outdated, tedious, and time consuming.
Conventional methods approved by NAVSEA for measuring the soluble salts remaining on a substrate prior to paint application (specifically the Bresle patch method) are tedious, time consuming (approximately 8 minutes per test), and may leave adhesive residue on the surface. In addition these methods can be expensive (e.g. each Bresle patch costs $6.50 and can be used only once). Current technology utilized for measuring the soluble salts (specifically the Bresle patch method) Tedious & time consuming (8 minutes) Leaves residue on the surface Each Bresle patch costs ~$6.50 One use Manual record keeping Uses syringes in industrial practices
Equipment
Equipment for the approved Bresle method includes messy patches, needles, and a separate meter for measurements.
The currently approved Navy method has several drawbacks.
Drawbacks Time Requirements for Bresle method Approximately four minutes per test (field reported average time) NAVSEA requires five measurements every 1,000 ft2 or 1 measurement every 200 ft2 Requires Post Clean-up Process Removal of sticky film Seventeen Step Process Built in Errors Results in Poor Quality Assurance and Inspection Due to tedious process Bresle method (each measurement) Time 8 minutes/test QA Inspector Labor= $50/hour ($0.83/minute) Bresle Patch=$6.50
ARP Instruments, Inc.
Automated SSM. Intelligent QA.
The Solution: Soluble Salt Meter (SSM) #RPCT-07-001
A new inspection tool has been developed and manufactured to replace the Bresle patch method for soluble salt determination. This Soluble Salt Meter (SSM), for which United States Patent No. 6,946,844 was issued on 20 September 2005, was designed around the current US Navy Bresle patch salt inspection method. The SSM test protocol exactly duplicates the Bresle process, except that measurements are automated and there are no consumables. The complete test sequence requires only one minute ten seconds (verified by NAVSEA). NAVSEA has approved the SSM Model # RPCT-07-001 as an authorized alternative to the Bresle patch method. Equipment
The SSM seals, injects water, extracts salts, collects and stores measurements in one self contained system WITHOUT the use of patches or syringes.
Benefits Accurate, easy measurements Repeatable results Rugged, industrial hardened measurement device Simple operating instructions Reduced process steps (17 steps reduced to 6 steps) Reduced process time (only one minute reading to reading) Eliminate process induced surface contamination (sticky residue) Equipment easily transportable (tank inspections) Improved safety (syringes/needles eliminated) Operator error minimized Metered water injection Automatic data recording feature (configured to work with NAVSEA QA database systems) Automatically records both conductivity and equivalent NaCl concentration Electronic data can be exchanged to any Coating Technical File (CTF)
Side-By-Side Comparison
Technical Specifications
Bresle Patch Compartment Area: mm2 (square) Can vary 5% due to stretching Attachment Method: Adhesive Leaves residue Requires post measurement cleanup Water Injection Method: Syringe Prone to human error and injury Air Evacuation of patch: Syringe Time consuming Prone to human error SSM Compartment Area: 1250 mm2 (circular) Fixed footprint Attachment Method: Magnetic No effect on surface quality Proven to seal over deep pits Water Injection Method: Automated Accurate metering valve (3.0 0.04 ml) Air Evacuation: Automated Chamber relaxes automatically No time delays
Process Procedures
Bresle Patch SSM 1. 2. 3. 4. 5. 6. Select Bresle patch, remove the protective paper and the punched-out material; Adhere patch to surface (attempting to minimize trapped air); Fill syringe with 3ml deionized water; Inject half of the water into the patch. Reposition needle and evacuate air. Remove the needle from the patch. Holding the syringe with the needle pointing upwards, expel the air. Re-insert the needle into the compartment and inject the remainder of the solvent; Agitate Bresle patch with finger for 10-20 seconds; Extract solution using syringe; Transfer solution in syringe to Horiba B-173 meter; Take reading; Record reading by hand on QA sheet; NOTE: ISO 8502-6 dictates that during steps 3 to 10, it is essential that no solvent be lost from the patch or syringe. If any solvent is lost, the solution obtained shall be rejected. Remove Bresle patch from surface; Wipe remaining water from surface with rag Clean any adhesive remaining on surface; Clean and rinse out syringe; Clean Horiba meter. 1. 2. 3. 4. Attach meter to surface; Inject deionized water into measurement chamber with one press of the dose bottle; Meter automatically agitates solution (~ 40 seconds); Meter automatically takes reading; Displays reading on LCD screen Stores values electronically Wipe remaining water from surface after removing SSM Flush meter by turning over and injecting water from dose bottle.
7. 8. 9. 10. 11. 12.
6 Total Steps (1 min)
13. 14. 15. 16. 17.
17 Total Steps (~8 min)
Cost Comparison
This section includes a cost comparison between the Bresle method and the SSM. The time per test is approximated to be 8 minutes per test* for inspectors and reflects additional time required to enter and track measurements by hand. The SSM stores all data electronically, allowing easy data management and tracking. Bresle Patch Time = 8 min/test Labor = $50/hr ($0.83/min) Bresle Patch = $6.50 ~$13.00 per measurement ~$23,300 per year** SSM Time = 1 min/test Labor = $50/hr ($0.83/min) No consumable ~$0.83 per measurement ~$1,400 per year**
*Based on observational data of actual shipyard inspections. ** This is an estimate based on the labor and materials cost for 1700 measurements per year. These figures do not include expenses such as syringes, deionized water, and conductivity meters.
The initial SSM investment cost is returned with approximately 430 measurements. Depending on usage this could be as little as 3 months.
The SSM, a vast improvement over the Bresle method, is the most reliable, accurate, and repeatable method for measuring surface cleanliness
Summary
The SSM overcomes many of the inherent challenges of taking QA measurements. By reducing test cycle time and automating data measurement and tracking, the SSM will save money and improve QA. The SSM: Cuts sampling/inspection time; Simplifies the measurement process (17 steps reduced to 6 steps); Improves safety by eliminating the need for syringes and needles; Minimizes operator error through automatic metered water injection and electronic recording of measurements; Doesnt leave sticky residue on the substrate; Extracts surface salts more reliably for more accurate readings; Is equivalent to ISO Standard 8502-6 Extraction of soluble contaminants for analysis -- The Bresle method; Meets the requirements of ISO Standard 8502-9 Field method for the conductometric determination of water-soluble salts. Cost: Contact us for a price quote. Model Number: RPCT- 07-001 Distributed by: ARP Instruments, Inc.
INSTRUMENTS, INC.
www.arpinstruments.biz
SOLUBLE SALT METER (SSM)
MODEL NUMBER RPCT-07-001
Technical Bulletin
The SSM is a patented design that provides a hand held, automated method for detection of soluble salts on flat and curved surfaces. The model RPCT-07-001 meter has been performance tested by independent laboratories and approved by the United States Navys Naval Sea Systems Command (NAVSEA) as an alternative method for conductivity measurements. Surface salt extraction combined with conductivity and chloride concentration measurement in one convenient and ergonomic tool.
PRODUCT SUMMARY
The SSM was developed as a replacement for the Bresle patch inspection method (ISO 8502-6). The hand held design provides a self-contained, easily transportable unit for soluble salt measurements. The SSM and supplied fluid dispenser allow for quick and accurate injection of deionized water, extraction of surface salts, and conductivity measurement. The SSM is complete with a backlit LCD display and easy to follow on screen instructions. All data is stored electronically and can be downloaded to any PC spreadsheet program (such as Microsoft Excel), using the supplied SSMLink software. Electronic data can be exchanged into any Coating Technical File (CTF).
PROCESS STEPS
1. Attach meter to surface 2. Inject deionized water into SSM with one press of the dose bottle 3. Press Start: SSM automatically agitates solution, takes measurement, displays the result on LCD screen and stores data in memory. 4. Remove SSM and wipe remaining water from surface. 5. Clean meter by flushing SSM with deionized water. 5 Total Process Steps 1 minute
APPROVALS
United States Patent No. 6,946,844 was issued on 20 September 2005 covering this equipment.
International patent pending.
Approved by US Navy for soluble salt determination in accordance with the Preservation Process
Instruction (Core PPI)
Approved by the US Navy for Bresle patch alternative method in NAVSEA Standard Item 009-32 Equivalent to ISO Standard 8502-6 Extraction of soluble contaminants for analysis The Bresle
method
Can be used in lieu of the Bresle method with ISO Standard 8502-9 Field method for the
conductometric determination of water-soluble salts
METER DESCRIPTION
1. 2. 3. 4. 5. 6. 7.
MENU button ENTER button LCD screen Green/Red LED status indicator Piston Magnets Silicone seal
Plunger Power/USB port with protective plug 10. Tube connector 11. Shock absorber 12. Protective cap
THE SSM KIT
Your basic SSM kit consists of: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12.
Soluble Salt Meter with protective cap and rechargeable Li-ion battery with (Optional) additional measuring heads 500 mL of deionized water 250 mL of 84 S/cm standard solution 3 mL fixed volume fluid dispenser Stiff plastic feeder tube for dispenser Flexible plastic tubing to connect the SSM and dispenser Syringe for injection of calibration solution Universal AC adaptor (with instructions) Plugs for universal AC adaptor USB connection cable CD with SSMLink software (not pictured) Users manual (not pictured) Lanyard for hanging meter from neck to prevent damage if dropped (not pictured)
SSM FEATURES
Standards Equivalent to ISO Standard 8502-9 (Field method for the conductometric determination of water-soluble salts; The Bresle method) in accordance with NACE SP0508-2008
Measurement Area Attachment Method Water Injection Method Dose Air Evacuation Measurement Process Steps Total Process Time (Reading to Reading) Working Temperature Range Temperature Accuracy Conductivity Sensors Measurement Range Measurement Accuracy Diameter of Curvature Readout/Indicators Memory Power Supply Calibration SSMLink Software & SSMFirmware Updates
www.arpinstruments.biz ARP Instruments, Inc. SSM Technical Bulletin Version 2.8 3/2/2010
1250 mm2 (circular) fixed footprint Protective with silicone seal (no effect on surface quality; proven to seal over deep pits) Automated, with simple press of 3 mL fixed volume dispenser 3 0.05 mL Automated (measurement chamber relaxes automatically; no time delays) minute C (F) 0.3 C (0.54F) 4 probes (stainless steel) 0-100 S/cm 1% full scale Standard measuring head >= 44 inch / 1100mm Head 1- 24 <=> 42 inch / 650 <=> 1050mm Head 2- 14 <=> 24 inch / 350 <=> 600 mm Head 3- 8 <=> 12 inch / 200 <=> 300 mm
S/cm or mg/m2 (Red/Green LED)
Holds up to 1000 measurements (10 batches of up to 100 measurements each) Lithium-ion rechargeable battery 3.7 V @ 1880mAh Not required; meter is calibrated by manufacturer. Daily validation method provided. Contact manufacturer for calibration services. Visit www.arpinstruments.biz for periodic updates or to receive email updates or contact arp.instruments@gmail.com
Soluble Salt Meter (SSM)
For more information contact: ARP Instruments, Inc. arp.instruments@gmail.com P.O. Box 278 Garrisonville, VA 22463 Office: 540-752-7651 Fax: 540-752-5226
Tags
ASF245 SA-W505 SH-8016 RKI 8400 DCR-DVD505 MEX-1HD EP-70 CDM-7871 VCM8935 00T M4-S435 Wildfire Velocity 4400 TH-42PV70P Quest-1999 FX-570ES 97110 Eu R05 55PP9527 SGH-X150 Korg N5 LE46C750r2W YST-SW800 Nikon 4500 EWF1629 LQ-570 88101K-MN 00P Praxio Review CCD-TRV428E VFW 065 Viking 180 T1100 Expander P-2602HWL-C Inspiron 9100 Singer 307G Motion 2 Dumbells -9010 30 E EB-1915 W302C 25ML8966 Guide MC-D112B CMD 126 CW-29Z306T PRS-650 327700 CCD-TR3300E RX-V592RDS MS-204W FM33 2G AOI-892 Model 1140 Touch PRO2 Tennis-world Tour UN55C8000XF TC1000 KH 2424 Harmony 680 DVX286 HDC-SX5 ICF-CD855V Casio 4348 42PC3R MHC-RG495 Elna 2110 AV-R610 Keyboard BD-P1600 Supreme 1994 TXP37X10Y CTF-220 WM-FX855 Starlite Power FH RCM 127 C87 FE-140 BMW 328I 190000 KDL-37W5720 Terror VP-D372WH Awyahdp Assist Z205 EFW 6225 LG 505G DW960 TDA-7560R Spektrum DX7 GR-D350us-gr-d350 PSR-220 SGH-B270 UX-H100 M228WA-BM CPF-IX001 KE2041 4G MX Techna
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101





