Behringer LD-6230 6-CH hard-wire Output Dimmer PakYou can control it either digitally using its DMX512 interface or analog by using the additional 8-pole DIN connector. The LD6230 features an adjustable preheat & limiter function for prolonging bulb life. Various transmission characteristics of the control signals from the lighting console are made possible w/its precise curve function.The LD6230 features a switch option that allows a simple on/off control of each channel. An additional useful feature is the automatic digital input check fo... Read more
Details
Brand: BEHRINGER
Part Numbers: LD-6230, LD6230
UPC: 04033653100069, 4.03365E+12, 4033653100069
[ Report abuse or wrong photo | Share your Behringer Eurolight LD6230 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Behringer Eurolight LD6230, size: 742 KB |
Related manuals Behringer Eurolight LD6230 Installation Instructions |
Behringer Eurolight LD6230
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

INSTALLATION INSTRUCTIONS
Version 1.1 January 2004
EUROLIGHT LD6230
ENGLISH
INSTALLATION INSTRUCTIONS EUROLIGHT LD6230
IMPORTANT SAFETY INSTRUCTIONS
DETAILED SAFETY INSTRUCTIONS: 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all instructions. CAUTION: The units installation and initial operation must be done under the supervision of a qualified professional. To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside; refer servicing to qualified personnel. To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture. 5) Do not use this device near water. 6) Clean only with a dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturers instructions. 8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched particularly at plugs, extension cords, and the point at which they exit the unit. 11) Only use attachments/accessories specified by the manufacturer. 12) Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the device. When a cart is used, use caution when moving the cart/ device combination to avoid injury from stumbling over it.
WARNING:
This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosurevoltage that may be sufficient to constitute a risk of shock.
This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
13) Unplug this device during lightning storms or when not used for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the unit has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the device, the unit has been exposed to rain or moisture, does not operate normally, or has been dropped.
The BEHRINGER EUROLIGHT LD6230 Dimmer Pack was developed to meet the highest demands of light engineering. Its wide-ranging functions make it an all-purpose workhorse for various commercial applications (TV studios, theatre or live events). The EUROLIGHT LD6230 has all the important features needed to control your lighting equipment, yet its controls are clearly arranged and simple to use. You can select between digital DMX or analog control. You get trouble-free operation with the extensive LEDs used for signal error detection.
SAFETY AND INITIAL OPERATION
As soon as you connect your LD6230 to the mains, internal controls are activated. The six automated fuses (circuit breakers) can all handle 10 A and serve as overload protection for the connected equipment. Please keep in mind that activating circuit breakers 1, 2, 3, 4, 5 or 6 also means that the respective channels can conduct voltage.
IMPORTANT INFORMATION
Electronic controls are additionally protected with triple highsensitivity fuses located on the main board.
Installation as well as initial operation must be performed by qualified personnel. Always assure that your LD6230 is completely disconnected from the mains before removing the casing cover. The LD6230 was designed for indoor use only. Please keep in mind that sudden temperature changes (e.g. bringing your equipment from colder environments into warmer environments) may cause condensation on electronic components, leading to possible equipment damage and physical harm to the operator. Please adhere to all applicable national safety standards during installation. Please read the installation instructions and the enclosed users manual in their entirety to familiarize yourself with the LD6230 and all of its functions. Please follow all instructions and store both the installation instructions and the manual in a safe place for future reference. Please assure that your EUROLIGHT is sufficiently cooled and that it is not placed near heat sources that could cause overheating. If you want to run your EUROLIGHT on mains voltage other than factory-specified voltage, contact the nearest BEHRINGER service center. To effectively limit harmonic currents and avoid voltage fluctuations that could affect other electrical appliances, connect this equipment to an AC outlet that complies with all applicable technical standards. In all other cases, contact your local power supply provider for advice prior to usage.
Defective fuses must be replaced with fuses with identical rating!
The LD6230 is a Class I device in which a low-Ohm protective ground wire is an integral part of its safety design. During the installation, make sure that a low-Ohm protective conductor (< 0,1 Ohm) exists between all bare metal parts and the grounding on the main connector.
L1 L2 L3
Ppuhry 8C CH 2 8C"
CH 4 X
* Activation of control electronics and respective output channel
CONNECTOR TERMINAL STRIP
The connector terminal strip of your LD6230 is laid out for cables with diameters between 0.326 mm 2 (AWG 22) and 4 mm2 (AWG 12). When using flexible access lines, cable end contacts corresponding to manufacturer specifications have to be used. To assure good contact, skin the cable endings between 9 - 13 mm. During the installation, all applicable national standards need to be adhered to.
MAINS/ILLUMINANT CONNECTORS
To facilitate additional flexibility, your dimmer pack has a connector terminal strip. Cable bushings for connecting to the mains and your illuminants are located in the back. Flexibility is further enhanced with the option to retrofit a CEE connector and a 16-pin HARTING connector. Both fixed and mobile installations require compliance with IEC 61010-1:2001 (EN 6110-1:2001). In particular, a 3-phase separator (pursuant IEC60947-1 and IEC60947-3) needs to be included in the installation. This separator needs to be labeled according to IEC 60417-50008 and IEC 0417-5007. To assure compliance with Directive 89/336/EEC, only use specified upstream line filters with your EUROLIGHT. Using it without line filters specified by BEHRINGER may lead to electromagnetic interference. More detailed information on this subject can be found at www.behringer.com.
Illustration: LD6230 connector terminal strip When your LD6230 leaves the assembly plant, all incoming and outgoing neutral conductor connectors are bridged. The incoming phases L1/L1, L2/L2 and L3/L3 are always connected to one another in pairs and switched to the overload protection of the channels 1 to 6. They protect output connectors E1 to E6. Each of the channels can handle currents of maximum 10 Amperes. The green-yellow conductors (PE) may only be used as protective conductors.
The lowest cable gauge between L1 and L3, incoming neutral conductor (N) and protective earth (PE) is 4 mm 2 (AWG 12). For outgoing channels E1 to E6, use cables with gauges corresponding to the loads used (2.5 mm2 (AWG 14) or 1.5 mm2 (AWG 16)).
Phrrb6d
6 - - - 25
Ivhyp 6XB rpvbd@V VT6
1.5 2.12
During the installation, please adhere to all manufacturer instructions. Regardless from mains supply voltage, the maximum output current of the EUROLIGHT LD6230 is 10 A per dimmer circle. Please make sure that each dimmer load is connected to a separate channel. Never connect more than one output to just one common neutral conductor. ATTENTION: Due to electrocution danger, do not use your dimmer pack if there are bare cables visible.
CEE connector pin allocation
Removable mains connector cables with mains interconnections (pursuant IEC60320) must match the minimal load-carrying capacity of the connector or must comply with the IEC60799 standard. The interconnection and the cable must comply with prevalent nominal values (maximal voltage and current). During the installation, please adhere to the instructions provided by the connector manufacturer.
CONNECTION OPTIONS FOR FLEXIBLE USAGE
OUTPUT CONNECTOR (HARTING) In the back of your LD6230 there is a cable bushing for connecting your illuminants. Open the flap on the top of the LD6230 to get to the terminal clamps used for this purpose. Here you have the option to retrofit a 16-pin HARTING connector. To do that, you first have to remove the back-bearing cover sheet and connect the HARTING connector to the terminal clamps.
SPECIFICATIONS
Channels Number Load per channel Maximal load per channel Frequency Inputs Power supply 6 0.2 A min./10 A max. 10 A using a 3-phase connector 50/60 Hz 3-phase connector, internal terminal block/PG cable screw joint, CEE connector (optional installation by qualified personnel) 0 to +10 V via 8 pin DIN DMX512 via XLR 5 pin DMX512 via XLR 5 pin Internal terminal block/PG cable screw joint, HARTING (optional installation by qualified personnel) 10 A cable protection switch (type C) 2 x T 100 mA H/250 V 1 x T 160 mA H/250 V for voltage range 220 - 230 V (EU) 2 x T 160 mA H/250 V 1 x T 315 mA H/250 V for voltage range 120 V (UL)
QDIhvtrC6SUDIBprp
PIN 1 PIN 2 PIN 3 PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 Phase channel 1 Phase channel 2 Phase channel 3 Phase channel 4 Phase channel 5 Phase channel 6 free E1 PIN 9 Neutral channel 1 N N N N N N E2 PIN 10 Neutral channel 2 E3 PIN 11 Neutral channel 3 E4 PIN 12 Neutral channel 4 E5 PIN 13 Neutral channel 5 E6 PIN 14 Neutral channel 6 PIN 15 free
Analog Digital Outputs Digital Load
free - PIN 16 free Ground wires need to be fastened to their respective PE connectors
System fuses Load securing per channel Control section fuse
CEE POWER SUPPLY CONNECTOR Also located in the back is a cable bushing for the mains supply. Here, you can retrofit a 5-pin CEE 32 A mains connector by removing the back-bearing cover sheet and connect the CEE high-voltage connector to the connecting terminal. The following illustration shows how the connections are allocated:
Power supply Voltage
USA/Canada 120 V~, 60 Hz Europe/U.K./Australia 240 V~, 50 Hz Maximum power consumption 3 x 20 A Dimensions/Weight Dimensions (H x W x D) Weight approx. 3 1/3" (84.3 mm) x 19" (482.6 mm) x 15 9/10" (403.8 mm) approx. 20.3 lbs. (9.2 kg)
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.
FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE INFORMATION
Responsible party name: Address: MUSIC Group Services USA, Inc. 18912 North Creek Parkway, Suite 200 Bothell, WA 98011, USA Phone: +Fax: +673 7647
Phone/Fax No.:
complies with the FCC rules as mentioned in the followingparagraph: This equipment has been tested and found to comply with the limits for a ClassB digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the followingmeasures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician forhelp. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Important information: Changes or modifications to the equipment not expressly approved by MUSIC Group can void the users authority to use the equipment.
behringer.com
Technical specifications and appearance subject to change without notice. The information contained herein is correct at the time of printing. The names of companies, institutions or publications pictured or mentioned and their respective logos are registered trademarks of their respective owners. Their use neither constitutes a claim of the trademarks by BEHRINGER nor affiliation of the trademark owners with BEHRINGER. BEHRINGER accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained herein. Colors and specifications depicted may vary slightly from product. No part of this book may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind, for any purpose, without the express written permission of BEHRINGER Spezielle Studiotechnik GmbH. BEHRINGER is a registered trademark. ALL RIGHTS RESERVED. 2004 BEHRINGER Spezielle Studiotechnik GmbH. BEHRINGER Spezielle Studiotechnik GmbH, Hanns-Martin-Schleyer-Str. 36-38, 47877 Willich-Mnchheide II, Germany Tel. +9206 0, Fax +9206 4903
Technical specifications
Full description
You can control it either digitally using its DMX512 interface or analog by using the additional 8-pole DIN connector. The LD6230 features an adjustable preheat & limiter function for prolonging bulb life. Various transmission characteristics of the control signals from the lighting console are made possible w/its precise curve function.The LD6230 features a switch option that allows a simple on/off control of each channel. An additional useful feature is the automatic digital input check for detecting DMX signal errors. When in manual mode, dimming can be done even without an external lighting console. An auto store function saves all settings after leaving configuration mode. The dimmer pack features a 3-digit display & dedicated control LEDs as well as HARTINGr & CEE connection options (connectors not included).
Tags
X2550 23429 MP10 E RB-880 AG-DVC15 Review PRO 12 SA-PM47 WD5000H1q-00 24-230 JBV 9102D Of Fate - 2004 Optoma DV11 Darkening Hybrid FS-6700 32HW-57E NAV-62E LAB-M7500 Lansing BX21 NVX-Z555 Sennheiser E935 TC300 Motorola 8700 TSU9200 Navigator Biotec 30 Roadster VGN-Z11mn B Scaleo PA S3115H 47LB2RF XE-A303 PT-LC75E Printer ESF66030X E-500 Rotary Iron AM-NX9 KH 6519 LH-D6235 SCH-S259 Spirit E C6463A DCR-SR75E MX6445 350 VA TX28DTX-1 SGH-E250S DVC5935 SCH-U470 LAC-M7600R Ketron X8 DAV-SC6 DEH-434R UR4U-mdvr2 WF-T502 47PFL8404H Xpectia FZ3 AVR-1610 600YGR KDL-32EX701 RD-300S Made Easy Navigon 3100 CE 2000 81035 Biloba 680 SYS-391HT CLP-631 Hdci-2000 G 2220 Sensor 100 MX37-T-003 CVA 4080 29FX5CL P37-HR100CS Buzzsaw EED4100SQ CD4450S Microsampler XPS510 2605DN Babykostwarmer PB8253 6291500X61 BM-801 MX-3500N DE Luxe 5410T Topobase 2011 XL400 Junior H4100 Nokia 5230 STR-DA3600ES Edition Beyond PCG-K415B Reference
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding