Reviews & Opinions
Independent and trusted. Read before buy Behringer Xenyx 502!

Behringer Xenyx 502


Bookmark
Behringer Xenyx 502

Bookmark and Share

 

Behringer Xenyx 502Behringer Premium 5-Input 2-Bus Mixer w/XENYX Mic Preamp & British EQ
Their new XENYX mixers will take you to an even higher plane. The XENYX 502 has 5 inputs and main mix, stereo CD/tape plus separate headphone outputs. Additionally, assignable CD/tape inputs have been incorporated for routing flexibility. The new XENYX Mic Preamp matches the sound quality, transparency, headroom and even the dynamic range of boutique-style, stand-alone mic preamps. Behringer's neo-classic British EQ brings back the warmth and musicality of those 60s and 70s mega-console desk... Read more

Details
Brand: Behringer
Part Numbers: 000-57602-00000, XENYEX502
UPC: 4033653020787
[ Report abuse or wrong photo | Share your Behringer Xenyx 502 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Behringer Xenyx 502, size: 1.4 MB

 

Behringer Xenyx 502

 

 

Video review

BEHRINGER Xenyx 502 Mixer Demo

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 3. Page 1 of 1. Average Rating:
Nrune 7:58pm on Sunday, October 31st, 2010 
behringer xenyx 1832fx bought this a month ago, i am absolutely gobsmacked by this awesome mixer it does everything it says on the tin and a bit more. Good product.
BGMinf 4:52pm on Friday, October 1st, 2010 
great mixer .... and fx great mixer ... over 100 fx you take full contol of
all you need to do
a must fot dj / karoke djing
HeyYouItsMike 7:06am on Thursday, May 27th, 2010 
great mixer .... and fx great mixer ... over 100 fx you take full contol of all you need to do a must fot dj / karoke djing

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

User Manual

XENYX 502/802/1002/1202
Premium 5/8/10/12-Input 2-Bus Mixer with XENYX Mic Preamp and British EQ

behringer.com

XENYX 502/802/1002/1202 User Manual

Table of Contents

Thank you.. 2 Important Safety Instructions.. 3 Legal Disclaimer.. 3 Limited Warranty.. 3 1. Introduction... 5 1.1 General mixing console functions.. 5 1.2 The users manual... 5 1.3 Before you get started.. 5 1.3.1 Shipment... 5 1.3.2 Initial operation.. 5 1.3.3 Online Registration.. 5 2. Control Elements and Connectors.. 6 2.1 Mono channels... 6 2.1.1 Microphone and line inputs.. 6 2.1.2 Equalizer... 6 2.1.3 FX sends, panorama and level adjustment.. 6 2.2 Stereo channels... 6 2.2.1 Stereo line inputs... 6. 2.2.2 Equalizer stereo channels (802). 7 2.2.3 FX sends, balance and level adjustment. 7 2.3 Connector panel and main section.. 7 2.3.1 Send/return effects path.. 7 2.3.2 Monitor and main mix.. 7 2.3.3 CD/Tape connectors.. 8 2.3.4 Signal assignment.. 8 2.3.5 Phantom power and LED displays. 8 3. Installation... 8 3.1 Mains connection... 8 3.2 Audio connections.. 8 4. Specifications.. 10

Thank you

Congratulations! In purchasing our XENYX 502/802/1002/1202 you have acquired a mixing console whose small size belies its incredible versatility and audioperformance. The XENYX Series represents a milestone in the development of mixing console technology. With the new XENYX microphone preamps including phantom power as an option, balanced line inputs and a powerful effects section, themixing consoles in the XENYX Series are optimally equipped for live and studio applications. Owing to state-of-the-art circuitry your XENYX console produces a warm analog sound that is unrivalled. With the addition of the latest digital technology these best-in-class consoles combine the advantages of both analog and digital technology.
Important Safety Instructions
Terminals marked with this symbol carry electrical current of sufficient magnitude to constitute risk of electric shock. Use only high-quality commercially-available speaker cables with " TS plugs pre-installed. All other installation or modification should be performed only by qualified personnel. This symbol, wherever it appears, alerts you to the presence of uninsulated dangerous voltage inside the enclosure - voltage that may be sufficient to constitute a risk of shock. This symbol, wherever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual. Caution To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside. Refer servicing to qualified personnel. Caution To reduce the risk of fire or electric shock, do not expose this appliance to rain and moisture. The apparatus shall not be exposed to dripping or splashing liquids and no objects filled with liquids, such as vases, shall be placed on the apparatus. Caution These service instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operation instructions. Repairs have to be performed by qualified service personnel. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturers instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus. 11. Use only attachments/accessories specified by the manufacturer. 12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. 13. Unplug this apparatus during lightning storms or when unused for long periods of time. 14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection. 16. Where the MAINS plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.

Limited Warranty

1 Warranty
[1] This limited warranty is valid only if you purchased the product from a BEHRINGER authorized dealer in the country of purchase. A list of authorized dealers can be found on BEHRINGERs website behringer.com under Where to Buy, or you can contact the BEHRINGER office closest to you. [2] MUSIC Group* warrants the mechanical and electronic components of this product to be free of defects in material and workmanship if used under normal operating conditions for a period of one (1) year from the original date of purchase (see the Limited Warranty terms in 4 below), unless a longer minimum warranty period is mandated by applicable local laws. If the product shows any defects within the specified warranty period and that defect is not excluded under 4, MUSIC Group shall, at its discretion, either replace or repair the product using suitable new or reconditioned product or parts. In case MUSIC Group decides to replace the entire product, this limited warranty shall apply to the replacement product for the remaining initial warranty period, i.e., one (1) year (or otherwise applicable minimum warranty period) from the date of purchase of the original product. [3] Upon validation of the warranty claim, the repaired or replacement product will be returned to the user freight prepaid by MUSIC Group. [4] Warranty claims other than those indicated above are expressly excluded. PLEASE RETAIN YOUR SALES RECEIPT. IT IS YOUR PROOF OF PURCHASE COVERING YOUR LIMITED WARRANTY. THIS LIMITED WARRANTY IS VOID WITHOUT SUCH PROOF OF PURCHASE.

2 Online registration Please do remember to register your new BEHRINGER equipment right after your purchase at behringer.com under Support and kindly read the terms and conditions of our limited warranty carefully. Registering your purchase and equipment with us helps us process your repair claims quicker and more efficiently. Thank you for your cooperation! 3 Return materials authorization
[1] To obtain warranty service, please contact the retailer from whom the equipment was purchased. Should your BEHRINGER dealer not be located in your vicinity, you may contact the BEHRINGER distributor for your country listed under Support at behringer.com. If your country is not listed, please check if your problem can be dealt with by our Online Support which may also be found under Support at behringer.com. Alternatively, please submit an online warranty claim at behringer.com BEFORE returning the product. All inquiries must be accompanied by a description of the problem and the serial number of the product. After verifying the products warranty eligibility with the original sales receipt, MUSIC Group will then issue a Return Materials Authorization (RMA) number.

Legal Disclaimer

Technical specifications and appearance are subject to change without notice. The information contained herein is correct at the time of printing. All trademarks are the property of their respective owners. MUSIC Group accepts no liability for any loss which may be suffered by any person who relies either wholly or in part upon any description, photograph or statement contained herein. Colors and specifications may vary slightly from product. BEHRINGER products are sold through authorized dealers only. Distributors and dealers are not agents of MUSIC Group and have absolutely no authority to bind MUSIC Group by any express or implied undertaking or representation. This manual is copyrighted. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording of any kind, for any purpose, without the express written permission of Red Chip Company Ltd. ALL RIGHTS RESERVED. 2010 Red Chip Company Ltd. Trident Chambers, Wickhams Cay, P.O. Box 146, Road Town, Tortola, British Virgin Islands
[2] Subsequently, the product must be returned in its original shipping carton, together with the return authorization number to the address indicated by MUSIC Group. [3] Shipments without freight prepaid will not be accepted.
4 Warranty Exclusions [1] This limited warranty does not cover consumable parts including, but not limited to, fuses and batteries. Where applicable, MUSIC Group warrants the valves or meters contained in the product to be free from defects in material and workmanship for a period of ninety (90) days from date of purchase. [2] This limited warranty does not cover the product if it has been electronically or mechanically modified in any way. If the product needs to be modified or adapted in order to comply with applicable technical or safety standards on a national or local level, in any country which is not the country for which the product was originally developed and manufactured, this modification/adaptation shall not be considered a defect in materials or workmanship. This limited warranty does not cover any such modification/adaptation, regardless of whether it was carried out properly or not. Under the terms of this limited warranty, MUSIC Group shall not be held responsible for any cost resulting from such a modification/adaptation. [3] This limited warranty covers only the product hardware. It does not cover technical assistance for hardware or software usage and it does not cover any software products whether or not contained in the product. Any such software is provided AS IS unless expressly provided for in any enclosed software limited warranty. [4] This limited warranty is invalid if the factoryapplied serial number has been altered or removed from the product. [5] Free inspections and maintenance/repair work are expressly excluded from this limited warranty, in particular, if caused by improper handling of the product by the user. This also applies to defects caused by normal wear and tear, in particular, of faders, crossfaders, potentiometers, keys/buttons, guitar strings, illuminants and similar parts. [6] Damage/defects caused by the following conditions are not covered by this limited warranty: improper handling, neglect or failure to operate the unit in compliance with the instructions given in BEHRINGER user or service manuals; connection or operation of the unit in any way that does not comply with the technical or safety regulations applicable in the country where the product is used; damage/defects caused by acts of God/Nature (accident, fire, ood, etc) or any other condition that is beyond the control of MUSIC Group.

1. Introduction

XENYX Mic Preamps The microphone channels feature high-end XENYX Mic Preamps that compare well with costly outboard preamps in terms of sound quality and dynamics and boast the following features:
130 dB dynamic range for an incredible amount of headroom A bandwidth ranging from below 10 Hz to over 200 kHz for crystal-clear
understand the links between the controls, we have arranged them in groups according to their function. The illustrations at the beginning of each chapter show the controls described in each respective chapter.
The block diagram supplied with the mixing console gives you an
overview of the connections between the inputs and outputs, as well as the associated switches and controls. For the moment, just try and trace the signal path from the microphone input to the FX send connector. Dont be put off by the huge range of possibilities; itseasier than you think! If you look at the overview of the controls at the same time, youll be able to quickly familiarize yourself with your mixing console and youll soon be making the most of all its many possibilities. If you need to know more about specific issues, please visit our website at http://behringer.com, where youll find explanations of (for example) effects and dynamics applications.
reproduction of even the finest nuances
The extremely low-noise and distortion-free circuitry guarantees absolutely
natural and transparent signal reproduction
They are perfectly matched to every conceivable microphone with up to
60dB gain and +48 volt phantom power supply
They enable you to use the greatly extended dynamic range of your
24-bit/192-kHz HD recorder to the full, thereby maintaining optimal audioquality British EQ The equalizers used for the XENYX Series are based on the legendary circuitry of top-notch consoles made in Britain, which are renowned throughout the world for their incredibly warm and musical sound character. Even with extreme gain settings these equalizers ensure outstanding audio properties.
1.3 Before you get started
1.3.1 Shipment Your mixing console was carefully packed in the factory to guarantee safe transport. Nevertheless, we recommend that you carefully examine the packaging and its contents for any signs of physical damage, which may have occurred during transit.
If the unit is damaged, please do NOT return it to us, but notify your

dealer and the shipping company immediately, otherwise claims for damage or replacement may not be granted. 1.3.2 Initial operation Be sure that there is enough space around the unit for cooling purposes and to avoid over-heating please do not place your mixing console on high-temperature devices such as radiators or power amps. The console is connected to the mains via the supplied cable. The console meets the required safety standards. Blownfuses must only be replaced by fuses of the same type and rating.
Never connect the XENYX to the power supply unit when the latter is

Caution!

We should like to draw your attention to the fact that extreme volumes
may damage your hearing and/or your headphones or loudspeakers. Turn the MAIN MIX control and PHONES control in the main section fully counter-clockwise before you switch on the unit. Always be careful to set appropriate volume levels.
Important notes concerning installation
The sound quality may diminish within the range of powerful
connected to the mains! First connect the power supply unit to the console, then connect the power supply unit to the mains.
Please note that all units must be properly grounded. For your own
broadcasting stations and high-frequency sources. Increase the distance between the transmitter and the device and use shielded cables for all connections.
safety, you should never remove any ground connectors from electrical devices or power cables, or render them inoperative.
Please ensure that only qualified people install and operate the
1.1 General mixing console functions
A mixing console fulfils three main functions:
Signal processing: Preamplification, level adjustment, mixing of effects,
mixing console. During installation and operation, the user must have sufficient electrical contact to earth, otherwise electrostatic discharges might affect the operation of the unit. 1.3.3 Online Registration Please register your new BEHRINGER equipment right after your purchase by visiting http://behringer.com and read the terms and conditions of our warrantycarefully. Should your BEHRINGER product malfunction, it is our intention to have it repaired as quickly as possible. To arrange for warranty service, please contact the BEHRINGER retailer from whom the equipment was purchased. Should your BEHRINGER dealer not be located in your vicinity, you may directly contact one of our subsidiaries. Corresponding contact information is included in the original equipment packaging (Global Contact Information/European Contact Information). Should your country not be listed, please contact the distributor nearest you. A list of distributors can be found in the support area of our website (http://behringer.com). Registering your purchase and equipment with us helps us process your repair claims more quickly and efficiently. Thank you for your cooperation!

frequency equalization.

Signal distribution: Summing of signals to the aux sends for effects
processing and monitor mix, distribution to one or several recording tracks, power amp(s), control room and 2-track outputs.
Mix: Setting the volume level, frequency distribution and positioning of the
individual signals in the stereo field, level control of the total mix to match the recording devices/crossover/power amplifier(s). All other mixer functions can be included in this main function. The interface of BEHRINGER mixing consoles is optimized for these tasks enabling you to easily keep track of the signal path.

1.2 The users manual

The users manual is designed to give you both an overview of the controls, aswell as detailed information on how to use them. In order to help you
2. Control Elements and Connectors
This chapter describes the various control elements of your mixing console. Allcontrols, switches and connectors will be discussed in detail.
LOW CUT In addition, the mono channels (1002 and 1202) are equipped with a steep LOWCUT filter (slope at 18 dB/oct., -3 dB at 75 Hz) designed to eliminate unwanted low-frequency signal components. 2.1.3 FX sends, panorama and level adjustment FX (802/1002/1202 only) FX sends (or AUX sends) enable you to feed signals via a variable control from one or more channels and sum these signals to a bus. The bus appears at the consoles FX send output and can be fed from there to an external effects device. The return from the effects unit is then brought back into the console on the aux return connectors (802) or normal channel inputs. Each FX send is mono and features up to +15 dB gain. As the name suggests, the FX sends of the XENYX mixing consoles are intended to drive effects devices (reverb, Fig. 2.3: The FX send/ delay, etc) and are therefore configured post-fader. panorama/level controls This means that the mix between dry signal and effect remains at the level determined by the channels aux send, irrespective of the channel fader setting. If this were not the case, theeffects signal of the channel would remain audible even when the fader is lowered to zero. PAN The PAN control determines the position of the channel signal within the stereo image. This control features a constant-power characteristic, which means the signal is always maintained at a constant level, irrespective of position in the stereo panorama. LEVEL The LEVEL control determines the level of the channel signal in the main mix. CLIP The CLIP LEDs of the mono channels illuminate when the input signal is driven too high, which could cause distortion. If this happens, use the GAIN control to reduce the preamp level until the LED does not light anymore.

2.1 Mono channels

2.1.1 Microphone and line inputs MIC Each mono input channel offers a balanced microphone input via the XLR connector and also features switchable +48 V phantom power supply for condenser microphones. TheXENYX preamps provide undistorted and noise-free gain as is typically known only from costly outboardpreamps.

Please mute your playback system before
you activate the phantom power supply to prevent switch-on thumps being directed to your loudspeakers. Please also note the instructions in chapter 2.3.5 Phantom power and LED displays. LINE IN
Fig. 2.1: Connectors and controls of mic/line inputs
Each mono input also features a balanced line input on a " connector. Unbalanced devices (mono jacks) can also be connected to these inputs.
Please remember that you can only use either the microphone
or the line input of a channel at any one time. You can never use bothsimultaneously! GAIN Use the GAIN control to adjust the input gain. This control should always be turned fully counterclockwise whenever you connect or disconnect a signal source to one of the inputs. 2.1.2 Equalizer All mono input channels include a 3-band equalizer, except for the 502, which is equipped with a 2-band EQ. All bands provide boost or cut of up to 15 dB. Inthe central position, the equalizer is inactive. The circuitry of the British EQs is based on the technology used in the best-known top-of-the-line consoles and providing a warm sound without any unwanted side effects. The result are extremely musical equalizers which, unlike simple equalizers, cause no side effects such as phase shifting or bandwidth limitation, even with extreme gain settings of 15 dB. EQ The upper (HI) and the lower band (LO) are shelving filters that increase or decrease all frequencies above or below their cut-off frequency. The cut-off frequencies of the upper and lower band are 12 kHz and 80Hz respectively. Themid band (802/1002/1202) is configured as a peak filter with a center frequency of 2.5 kHz.

2.2 Stereo channels

2.2.1 Stereo line inputs LINE IN
Fig. 2.2: The equalizer of the mono input channels
Each stereo channel has two balanced line level inputs on " jacks for left and right channels. If only the jack marked L (left) is used, the channel operates in mono. The stereo channels are designed to handle typical line level signals. Both inputs will also accept unbalanced jacks.
Fig. 2.4: Stereo line inputs
2.2.2 Equalizer stereo channels (802) The XENYX 802 features a stereo 3-band EQ in each stereo channel. The filter characteristics and cut-off frequencies are the same as those in the monochannels. A stereo EQ is highly preferable to two mono equalizers. when working on a stereo signal, astwoseparate EQs will usually produce an unwanted discrepancy between the left and rightchannels.

FX SEND The FX SEND output (does not apply for 502) should be connected to the input of an external effects unit. The post-fader FX signal you created using the input channel FX controls is sent to the effects unit via the FX SEND ouput. Use the FXSEND control of the main section to adjust the overall send level (1002and1202 only). 2.3.2 Monitor and main mix
Fig. 2.5: The equalizer of the stereo input channels
PHONES/CONTROL ROOM The stereo PHONES jack (at the top of the connector panel) is where you connect headphones. The unbalanced CTRL ROOM OUT jacks carry the summed effects and main mix signals, as well as soloed channel signals. The PHONES/CONTROL ROOM control adjusts the level of both headphones and main monitor outputs. The 502 is not equipped with control room outputs.
2.2.3 FX sends, balance and level adjustment FX The FX sends of the stereo channels function similar to those of the mono channels. However, since the FXsend buses are both mono, a mono sum is first taken from the stereo input before it is sent to the FXbus. The 502 is not equipped with FXsends. BAL The BAL(ANCE) control determines the levels of left and right input signals relative to each other before both signals are then routed to the main stereo mix bus. If a channel is operated in mono via the left line input, thiscontrol has the same function as the PANcontrol used in the mono channels. LEVEL The LEVEL control determines the volume of the channel being sent to the mainmix. +4/-10 The stereo inputs of the XENYX 1002 and 1202 have an input sensitivity switch which selects between +4 dBu and -10 dBV. At -10dBV (home-recording level), the input is more sensitive (requires less level to drive it) than at +4 dBu (studiolevel).
Fig. 2.6: The FX send/balance/ level controls Fig. 2.9: Monitor/main mix connectors
MAIN MIX The MAIN OUT connectors are unbalanced mono jacks. The main mix signal appears here at a level of 0 dBu. The MAIN MIX fader adjusts the volume of these outputs. The XENYX 802 and 502 mixing consoles feature a rotary control for thispurpose.
2.3 Connector panel and main section
2.3.1 Send/return effects path STEREO AUX RETURN 802 only: the STEREO AUX RETURN connectors are used to bring the output of the external effects device (whoseinput is derived from the aux sends) back into the console. You can instead use these connectors as Fig. 2.7: FX send/return additional inputs, but any effects device will then have to connectors be brought back into the console via a normal stereo channel. This does, however, give you the ability to use the channel EQ on the effects return signal if you wish.
When using a stereo channel as effects return

Fig. 2.10: Monitor control and main mix fader
path, the FX control of the relevant channel should generally be turned fully down to avoid undesirable feedback.
If only the left connector is used, the AUX RETURN automatically operates in mono. Use the AUX RETURN control to determine how much of the effects signal is sent to the main mix.
Fig. 2.8: FX send/return controls
2.3.3 CD/Tape connectors CD/TAPE INPUT The CD/TAPE INPUTs are used to bring an external signal source (e.g. CD player, tape deck, etc.) into the console. They can also be used as a standard stereo line input, so the output of a second XENYX or BEHRINGER ULTRALINK PRO MX882 can be connected. Alternatively the line or tape output of a hi-fi amplifier with source selection switch could also be hooked up here, allowing you to easily listen to additionalsources. CD/TAPE OUTPUT These connectors are wired in parallel with the MAIN OUT and carry the main mix signal (unbalanced). Connect the CD/TAPE OUTPUT to the inputs of your recording device. The output level is adjusted via the high-precision MAIN MIX fader or rotary control (802). 2.3.4 Signal assignment CD/TAPE TO MIX When the TAPE TO MIX switch is depressed, the2-track input is assigned to the main mix providing an additional input for tape machines, MIDI instruments or other signal sources that do not require any processing. CD/TAPE TO CTRL ROOM (502: CD/TAPE TO PHONES)
Fig. 2.12: Assignment switches of the main section Fig. 2.11: CD/Tape input/output
+48 V The red +48 V LED lights up when phantom power is on. The PHANTOM switch activates the phantom power supply on the XLR connectors of all mono channels.
Please do not connect microphones to the mixer (or the stagebox/
wallbox) as long as the phantom power supply is switched on. Connectthe micro-phones before you switch on the power supply. Inaddition, the monitor/PA loudspeakers should be muted before you activate the phantom power supply. After switching on, wait approx. one minute in order to allow system stabilization. POWER The blue POWER LED indicates that the console is powered on. Level indicator The high-precision 4-segment display accurately displays the relevant signallevel. LEVEL SETTING: To correctly set the gains of the channels, first set the LEVEL controls of the input channels to their center positions (0 dB). Then use the GAIN controls to increase the input amplification until signal peaks show 0 dB on the level meter. When recording to digital recorders, the recorders peak meter should not go into overload. While analog recorders can be overloaded to some extent, creatingonly a certain amount of distortion (which is common and often desirable), digitalrecorders distort quickly when overloaded. In addition, digital distortion is not only undesirable, but also renders your recording completely useless.

The peak meters of your XENYX display the level virtually independent
of frequency. A recording level of 0 dB is recommended for all signaltypes.
Press the CD/TAPE TO CTRL ROOM/PHONES switch if you want to monitor the 2-track input via the CTRL ROOM OUT. This provides an easy way to monitor signals coming back from tape to ensure that they are recording correctly.
If you are recording a signal via the CD/TAPE OUTPUT and wish to

3. Installation

3.1 Mains connection
AC POWER IN Connect the power supply to the 3-pin mains connector on the rear of the console. Use the AC adapter supplied to connect the console to the mains. Theadapter complies with all applicable safety standards.
Please use only the power supply unit provided with the console. Never connect the XENYX to the power supply unit while the latter is
listen to this simultaneously via the CD/TAPE INPUT, do not use the CD/TAPE TO MIX switch. Doing this would create a feedback loop, since the signal would be routed, via the main mix, back to tape via the CD/TAPE OUTPUT. To monitor the CD/TAPEINPUT, usethe CD/TAPE TO CTRL ROOM switch to assign the tape signal to the monitor(s) or headphones. Thiswill avoid the tape signal being routed to the CD/TAPE OUTPUT. FX TO CTRL ROOM If you want to monitor only the FX send signal in your headphones or monitor speaker(s), press the FX TO CTRL switch. This mutes the main mix signal while routing the FX SEND output to the monitor(s). The XENYX 802 and 502 do not feature this switch. 2.3.5 Phantom power and LED displays
connected to the mains! First connect the console to the power supply unit, then connect the power supply unit to the mains.
Please note that both the power supply unit and the mixing console
heat up considerably during operation. This is completely normal.

3.2 Audio connections

You will need a large number of cables for different applications. Theillustrationsbelow show how the connectors should be wired. Be sure to useonly high-gradecables. Please use commercial RCA cables to connect the 2-track inputs and outputs. You can, of course, also connect unbalanced devices to the balanced inputs/ outputs. To do this, use either mono plugs or stereo plugs with the ring and sleeve bridged (pins 1 and 3 in the case of XLR connectors).

Caution! Never use unbalanced XLR connectors (PIN 1 and 3 connected)
on the MIC input connectors when using the phantom power supply.
Fig. 2.13: Phantom power and control LEDs
Balanced use with XLR connectors
Balanced " TRS connector

strain relief clamp

sleeve ring tip
1 = ground/shield 2 = hot (+ve) 3 = cold (-ve)

sleeve ground/shield

ring cold (-ve) tip hot (+ve)
For connection of balanced and unbalanced plugs, ring and sleeve have to be bridged at the stereo plug.

output

For unbalanced use, pin 1 and pin 3 have to be bridged
Fig. 3.1: XLR connections Fig. 3.3: " stereo plug Unbalanced " TS connector
Strain relief clamp Sleeve Tip
" TRS headphones connector
strain relief clamp sleeve ring tip
Sleeve (ground/shield) sleeve ground/shield

Tip (signal)

ring right signal tip left signal
Fig. 3.2: " mono plug Fig. 3.4: Stereo plug for headphones connection

4. Specifications

Mono Inputs Equalizer
Microphone inputs (XENYX Mic preamp) Type Mic E.I.N.1(20Hz - 20kHz) @ 0 source resistance -134dB / 135.7dB A-weighted @ 50 source resistance -131dB / 133.3dB A-weighted @ 150 source resistance -129dB / 130.5dB A-weighted Frequency response <10Hz - 150kHz <10Hz - 200kHz Gain range Max. input level Impedance Signal-to-noise ratio Distortion (THD+N) Line input Type Impedance Gain range Max. input level Main fader closed Channel muted Channel fader muted <10Hz - 90kHz <10Hz - 160kHz Stereo inputs Type Impedance Max. input level " TRS jack, electronically balanced approx. 20k +22dBu " TRS jack, electronically balanced approx. 20k balanced, approx. 10k unbalanced -10dB to +40dB +22dBu @ 0dB GAIN 90dB 89.5dB 89dB +0dB / -1dB +0dB / -3dB -1dB -3dB +10dB to +60dB +12dBu @ +10dB GAIN approx. 2.6k balanced 110dB / 112dB A-weighted (0dBu In @ +22dB GAIN) 0.005% / 0.004% A-weighted XLR connector, electronically balanced, discrete input circuit
EQ mono channels LOW MID HIGH EQ stereo channels LOW MID HIGH

Send/Return

80Hz / 15dB 2.5kHz / 15dB 12kHz / 15dB 80Hz / 15dB 2.5kHz / 15dB 12kHz / 15dB
Aux sends Type Impedance Max. output level Stereo aux returns Type Impedance Max. input level

Outputs

" TS jack, unbalanced approx. 120 +22dBu " TRS jack, electronically balanced approx. 20k balanced / approx. 10k unbalanced +22dBu
Main outputs Type Impedance Max. output level Control room outputs Type Impedance Max. output level Headphones output Type Max. output level

" TRS jack, unbalanced approx. 120 unbalanced +22dBu " TS jack, unbalanced approx. 120 +22dBu " TRS jack, unbalanced +19dBu / 150 (+25dBm) -106dB / -109dB A-weighted -95dB / -98dB A-weighted -84dB / -87dB A-weighted
Fade-out attenuation2 (Crosstalk attenuation)
Frequency response (Mic In Main Out)
Main mix system data (Noise) Main mix @ -, channel fader @ - Main mix @ 0dB, channel fader @ - Main mix @ 0dB, channel fader @ 0dB

Power Supply

Physical/Weight
502/802/1002 Power consumption USA/Canada Adapter Mains voltage Europe/U.K./Australia Adapter Mains voltage China Adapter Input Output Korea Adapter Mains voltage Japan Adapter Mains voltage 1202 Power consumption USA/Canada Adapter Mains voltage Europe/U.K./Australia Adapter Mains voltage China Adapter Input Output Korea Adapter Mains voltage Japan Adapter Mains voltage BEHRINGER PSU MX5JP 100V~, 50/60Hz BEHRINGER PSU MX5KR 220V~, 60Hz BEHRINGER PSU MX5CC 220V~ 50Hz; 150mA 2 x 17.5V~, 2 x 650mA BEHRINGER PSU MX5EU 230V~, 50Hz BEHRINGER PSU MX5UL 120V~, 60Hz 20W BEHRINGER PSU MX3JP 100V~, 50/60Hz BEHRINGER PSU MX3KR 220V~, 60Hz
502 13W BEHRINGER PSU MX3UL 120V~, 60Hz BEHRINGER PSU MX3EU 230V~, 50Hz BEHRINGER PSU MX3CC 220V~ 50Hz; 80mA 2 x 18.5V~, 2 x 150mA Weight (net) 1202 Dimensions (H x W x D) Weight (net)
Equivalent Input Noise Measuring conditions: 1 kHz rel. to 0 dBu; 20 Hz - 20 kHz; line input; main output; unity gain.
Dimensions (H x W x D) Weight (net) 802 Dimensions (H x W x D) Weight (net) 1002 Dimensions (H x W x D)
1.9" / 1.5 x 5.3 x 7" 47mm / 37 x 134 x 177mm 1.2lbs / 0.55kg 1.9" / 1.5 x 7.4 x 8.7" 47mm / 37 x 189 x 220mm 2.2lbs / 1.00kg 1.9" / 1.5 x 7.4 x 8.7" 47mm / 37 x 189 x 220mm 2.3lbs / 1.05kg 1.9" / 1.5 x 9.5 x 8.7" 47mm / 37 x 242 x 220mm 3lbs / 1.35kg
20 Hz - 20 kHz; measured at main output. Channels 1 - 4 unity gain; EQ flat; all channels on main mix; channels1/3 as far left as possible; channels 2/4 as far right as possible; reference = +6 dBu.
BEHRINGER is constantly striving to maintain the highest professional standards. As a result of these efforts, modifications may be made from time to time to existing products without prior notice. Specifications and appearance may differ from those listed or illustrated.

 

Technical specifications

Full description

Their new XENYX mixers will take you to an even higher plane. The XENYX 502 has 5 inputs and main mix, stereo CD/tape plus separate headphone outputs. Additionally, assignable CD/tape inputs have been incorporated for routing flexibility. The new XENYX Mic Preamp matches the sound quality, transparency, headroom and even the dynamic range of boutique-style, stand-alone mic preamps. Behringer's neo-classic British EQ brings back the warmth and musicality of those 60s and 70s mega-console desks that made music history. XENYX: Connect to Premium Analog Sound and Streaming Digital Technology. Getting all the gear you need to complete your PA system can be a chore. AMS offers complete PA packages that take the guesswork out, and make assembling the perfect sound system easy-while saving you money. Behringer XENYX 502 Features Premium ultra low-noise, high headroom analog mixer State-of-the-art XENYX Mic Preamp comparable to stand-alone boutique preamps Neo-classic British 2-band EQ for warm and musical sound Main mix, stereo CD/tape plus separate headphone outputs CD/tape inputs assignable to headphone output or main mix outputs High-quality components and exceptionally rugged construction ensure long life Conceived and designed by BEHRINGER Germany

 

Tags

D-EJ925 PC E830 2-1-0 ER-A330 Becker Z203 WL-312 PCS-1 Server 2 ICN320 FM37 4G PDP9512K Wide Zoom KX-TCD220FX Server SU-V670 Armada 4100 PRO520XL Nokia 810 23-32-45 KW BAR383HGA Mixer Review Quattro 72145 EWF1434 50V500A Cabriolet Power Supply Triton C200 Lite Asko 7005 Presario 6500 AC205 MAX-A66 SP101 Acoustics GT40 Intuos4 Guess WHO Cafamosacf200 GC2510 02 DCR-TRV890E DSC-W350 TH-46PZ85E SCH-R610 Beogram 8000 Nokia 6600 HMX-T10BP Mini Audio Mixer Review C2200 HTS3377 EB-450W Phantom Power DJ-X7E GYM 1000 BG 19 TH-42PZ700E Premier Kettler X1 Designjet 800 Dorina 75 PR 270 LX-M150D G-1000DXA RS 6 Afcv9033X RHT-G900 ALL-IN-ONE AP400 Quest 2 Adapter Soaker TAG A2618S Idect X3 DRA-F101 Price RX-450 LVS769 VLS517 Cyber 410 Roomba 510 Multi-detector Trim KIT PS42Q97HD MV920 Abit BH7 Office 10 Yamaha B-70 Muvo 100 T-4700 KV20EXR20 CI-5100C Yamaha MU15 CLP-350N RS20nrps5 CTK-480 WM1812CW IS 250C UA55C7000WF S3000 All-IN-ONE 740GM-p21 Mixing Desk DMR-EH50 SP6C II LE37A451c1 Flash 8 Toolbox 7

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101