Reviews & Opinions
Independent and trusted. Read before buy Chamberlain HC600MLS!

Chamberlain HC600MLS

 

 

About Chamberlain HC600MLS
Here you can find all about Chamberlain HC600MLS like manual and other informations. For example: review.

Chamberlain HC600MLS manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Chamberlain HC600MLS please write about it to help other people.
[ Report abuse or wrong photo | Share your Chamberlain HC600MLS photo ]

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Chamberlain HC600MLS, size: 5.5 MB

Chamberlain HC600MLS

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

D GB E F

FOTOCLULAS

SVTELN ZVORA

PHOTOCELLS

CELLULES PHOTOLECTRIQUE Modle 771E/771EML Model 771E/771EML Model 771E/771EML
LICHTSCHRANKE Modell 771E/771EML

PEC-0001

Chamberlain GmbH Alfred-Nobel-Strasse 4 D66793 Saarwellingen Tel.: +49(0)6838/907-0

Material Ident Nr.

GR HR NL PL P I H
FNYSOROMPK zem 771E/771EML FOTOCELLULE Modello 771E/771EML
771E/771EML SVJETLOSNE RAMPE Model 771E/771EML

Modelo 771E/771EML

EC - Producers - Declaration of Conformity Chamberlain GmbH Alfred-Nobel-Strasse 4 D66793 Saarwellingen
BARREIRAS LUMINOSAS Modelo 771E/771EML ZAPORY WIETLNE 771E/771EML Model 771E/771EML
FOTOCELBEVEILIGING Model 771E/771EML
declare, that the following machinery complies with all the essential health and safety requirements of the Directive Description of machinery: Photocell Type of machinery: PEC-0001 EU Directives: EC Directive for low voltage 2006/95/EC EC Directive electromagnetic compatibility 2004/108/EC with amendments Applicable harmonized standards: EN 55011, EN 55014, EN 60555-2/-3 B.P.Kelkhoff Manager, Regulatory Affairs Chamberlain GmbH D-66793 Saarwellingen July 2008
Sensormodul Module dtecteur Sensor module Sensormodule

100-150mm

LM600A/LM800A/LM1000A

o 180s 120s 60s

3780/5580
ML700/ML750/ML850 CB3 BAS300
CB24 LYN300-24 LYN400-24 SCS300-24 ART300-24 SUB300-24

OPEN EDGE PHOTO

OPEN PHOTO

CLOSE PHOTO

LYN300 LYN400 SCS300 ART300 ECO300 ECO400 SUB300
HC280ML HC300ML HC400ML HC600ML

SLY300 SLY500 SLY1000

HC100ML HC500ML
Non-compliance with the checking and adjustment requirements for the safety reverse system can result in a closing door causing serious, life-threatening injuries. An appropriate test should be carried out and repeated on a monthly basis. If necessary, the sensors need to be readjusted.

CAUTION!

INSTALLATION - GARAGE DOORS The transmitter lens transmits an invisible beam of light to the receiver lens. When the light beam is interrupted during the closing process, the door stops and re-opens completely. This installation method is the same for vertically opening sectional doors and canopy doors. The CB3 control unit permits the connection of two pairs of light barriers (opening & closing). In such cases, one pair of sensors can be installed at the sides of the door on both the inside and outside (fig. 3). However, the sensors must be mounted and connected in such a way that the transmitter and receiver lens are located exactly opposite each other as shown in (fig. 3). The sensors must be mounted securely to a solid surface, such as the posts or wall on both sides of the door. The invisible beam of light may not be interrupted. No part of the garage door (e.g. door rails, springs, hinges, rollers, other hardware, etc.) may interrupt the beam during the closing process. If this is not possible, an upright column element (accessory) has to be ordered. For the protection of infants and small children, the safety light barrier should not be installed higher than 150mm-200mm above the garage floor. INSTALLATION - SWINGING DOORS - SLIDING DOORS The transmitter lens transmits an invisible beam of light to the receiver lens. When the light beam is interrupted during the closing process, the door stops and re-opens completely. When the light beam is interrupted during the opening process, the door stops completely or stops until such time as the beam is no longer interrupted (depending on the given control unit and adjustment settings). The control units permit the connection of several pairs of light barriers. The sensors must be mounted securely to a solid surface and be located exactly opposite each other. Very important to note in this connection is that the slope or inclination of entrances be given due consideration. Cable lengths in excess of 10m should be avoided. Light from a low sun or excessively thin cable can seriously restrict the range available. If two pairs of light barriers are mounted closely together (sliding door), the receiver/transmitter may not be located on the same side of the entrance as otherwise one transmitter lens would influence the two receiver lens. For the protection of infants and small children, the safety light barrier should not be installed higher than 200mm-250mm above the garage floor. ASSEMBLY/MOUNTING The power supply must be disconnected prior to assembling/mounting the safety light barrier. 1. Open housing as shown in fig. 1. 2. Align sensor such that the lens are located laterally to the door and point exactly at each other. 3. Fasten sensors in place with screws / plugs. 4. Inside the garage, use insulated staples to fasten the cable to the wall and ceiling. Outdoors, only use cable approved for such applications and, if necessary, run it through an empty tube. High voltage and low voltage may not be run together through one cable as this may disrupt the sensors. Ensure that the sensors are sufficiently watertight and that the rubber gasket is used for cable connections. 5. Connect the cable (min. 2 x 0.5mm) to the terminals as shown depending on the given control unit (figs a-h). a. Garage door openers: Select the model of your choice from the figs (a,b,c,d,e). The cable from the plus terminal on the sensor should be connected to terminal 3 (black). The other one should be connected to terminal 2 (white). b. Openers for swinging doors and sliding doors: Select the model of your choice from the figs (f,g,h) and connect the cable as shown. Connect plus/plus - minus/minus 6. Connect power supply to opener. a. The two indicators, both in the transmitter lens and the receiver lens should light up if the terminal connections and alignment are correct. b. Should the light indicators flash (if the invisible light beam is blocked), the sensors need to be aligned. Loosen the receiver lens housing such that the sensor can be moved slightly. Adjust the sensor vertically and/or horizontally until the red indicator lights up and stops flashing. Washers or the like may have to be fitted. 7. CHECKING THE SAFETY LIGHT BARRIER Press the key on the remote control or the switch for opening the door. Place a sufficiently large obstacle under the door (see fig. 2 as an example) such that the sensor beam in the doorway is interrupted. Press the key on the remote control or the switch for closing the door. The garage door opener/door does not close when activated via the remote control if the light indicator in one of the sensors is flashing (which means that the sensor is incorrectly aligned or blocked by an obstacle). Consult a specialist in cases where the opener closes the door despite its path being blocked by an obstacle. TROUBLESHOOTING 1. In cases where the transmitter or receiver indicator light does not light up after installation, please check the following: Power supply to opener. Short circuit in the cable. This can occur under fasteners or at the connection terminals. Incorrect cable connection between sensor and opener. Interruption of circuit (interrupted connection). Polarity of cable wrong way round. 2. In cases where both sensors are flashing: Align sensors or remove obstacle. You must ensure that the signal from the light barrier recognises the presence of persons or objects (vehicle). Without additional safety precautions, the sensors do not guarantee total safety. Safety class: IP44 Temperature range: 40C + 60C Current consumption: max. 20mA Range: 10m

 

Tags

HQ8885 DVD-2500 Disco 96 Motor 2H DCR-HC38 Iden I415 AS-2400 Sedan Oregon 300 DVP3350V CQ-DFX600N DCR-HC15 VDR-D300 MPF920-Z VP-MX20C WR250R-2008 Speakers IEL9115-RF 08 ICF-S10mk2 Motorola Q700 DSR9500viaci DCR-DVD910E Yzea 800 JS-30 WA70B7 P2602HW-C Digital SPF-83V Samsung 173S FS608 TA-DA3400ES 3KF4866N SGH-F250 MX34U GR-T582G PF-60A30 MMA Platinum AWM-660 Kala 300 46A63 HCD-FX10 WRT54GL 3 0 AV-R620R Pcrcusz0 TX-SR8460 Command Unit CD2502S PD-F1007 PI 553 SR-18EX 32LG5010 HM160HI-lc1 DF-314 Geemarc CL1 CMT-LX20I 850 SW 2500D MS8137C KRF-V7771D Phks 66 IC-751A Pencentra 130 7000N SX-636 74850 Tuner Single CS-30L-cs-30-cs-10 Yoda 2005 KX-FP300 PN58C8000YF Stylus 7010 32LG5500 Review Clasic ICF-C390L KDC-308G 6 33 Evolution-VII 6561GM SL200 Server Vapeur VM-E565LA MDX-CA790 Ericsson T630 CMT-P555DVD Coolpix P80 Wavestation Style 1210 DV8821P CH-250 Guerrero DCR-TRV33K Fishfinder 250 DVR5100 Voice Isdn Presario 8000 TL-WN610G RSH1ptpe

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101