Reviews & Opinions
Independent and trusted. Read before buy Citizen CH607!

Citizen CH607


Bookmark
Citizen CH607

Bookmark and Share

 

Citizen CH607About Citizen CH607
Here you can find all about Citizen CH607 like manual and other informations. For example: review.

Citizen CH607 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Citizen CH607 please write about it to help other people.
[ Report abuse or wrong photo | Share your Citizen CH607 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Citizen CH607, size: 157 KB

 

Citizen CH607

 

 

Video review

Tensiometro digital marca citizen ch 607 BienBacano.com

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

English

INSTRUCTION MANUAL

Espaol Portugus Italiano
DIGITAL BLOOD PRESSURE MONITOR

MODEL CH607

CH 607

mm S. Hg

mm A. Hg

STA RT / ST OP

ME MO RY

PUL /M SE

Deutch Franais
English Espaol Portugus Deutsch

- Eng 1 -

GENERAL REMARKS
General remarks on blood pressure and blood pressure measurement
If the cuff is to be deflated quickly, depress Start/ Stop switch. The attached cuff is suited for a wrist circumference of 13.5 cm to 19.5 cm. When attaching the cuff, the body of the blood pressure monitor should be placed on the inside of your wrist. Self-measurement is no therapy! In no case should the dosage of medication ordered by the doctor be changed. In preparation for blood pressure measurement, you should urinate and should remain relatively still for 10 to 15 minutes prior to measurement. Exercise, eating and drinking, smoking, etc., prior to measurement may affect the results. The blood pressure varies constantly throughout the day. Measurement should be made regularly at the same time each day. Do not be too impressed by the results of one measurement. Keep a record of blood pressure variations. Many readings tell a story. Emotional stress may tend to cause blood pressure to rise. This product should not be used to monitor cardiac arrhythmia.
For proper measurement of blood pressure
Take a deep breath five or six times and then relax before measuring blood pressure. If you are tense when taking the measurement, you will not get a valid reading Blood pressure will be elevated when you are in a worrisome or irritated state, suffering from lack of sleep or constipation, or after exercise or a meal. Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the wrist and tighten it so that one finger may be inserted between the cuff and wrist. Do NOT measure blood pressure after bathing or drinking. When you feel like relieving yourself, you should do so before measuring blood pressure.

- Eng 2 -

Measure blood pressure where the room temperature is about 20C. DO NOT measure blood pressure when it is too cold (below 10C)or too hot (above 40C) in the room. DO NOT try to measure blood pressure immediately after drinking coffee or tea or smoking. Measure blood pressure with a relaxed and quiet posture. Keep the center of the cuff at the level of your heart, and do NOT move your arm or talk.
DO NOT measure blood pressure after the cuff has been on for a few minutes, as your arm will have built up higher blood pressure, and you will not get a valid reading.
English Espaol Portugus Italiano

PRECAUTION FOR USE

Precaution for use
If you suffer form heart disease, high blood pressure or other circulatory disease, please consult your doctor first. If you feel abnormal pressure of the cuff during use or any other irregularity, reduce the pressure by immediately switching off the power or removing the batteries and consult the sale outlet where you purchased. If you think the measured value is abnormal or if measuring makes you fell unwell, discontinue use and consult your doctor. Measurement of blood pressure may not be possible for someone with a weak pulse or arrhythmia. Congestion, swelling, etc. may occur in some people. If blood pressure is measured repeatedly, an accurate result will not be achieved. An interval of about 10 minutes should be allowed. The memory is erased if the batteries are removed for replacement, etc. and a record should be kept of any necessary data.

- Eng 3 -

Precaution for maintenance
Do NOT store the blood pressure meter where it will be exposed to direct sunlight, high temperature (over 60C), low temperature (below - 20C), high relative humidity (over 95%) or in a dusty place. Do NOT expose the blood pressure meter to undue force or vibration, or drop it. Remove the batteries when not use for a long time period. Do NOT disassemble the apparatus. Do NOT bend the cuff or Air hose unnecessarily. Never wipe the blood pressure monitor with thinner or benzene, as they may damage it. When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene.

Cleaning method of Cuff

After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it air dry. Hard rubbing or washing in a washing machine will cause air leakage. Also, be careful not to get water into the air hose.
Protect the natural environment
Please help protect the natural environment by respecting national and/or local recycling regulations when disposing of the batteries and the products at the end of their useful lives.
Nature and frequency of maintenance
This product is designed for use over an extended period of time; however it is generally recommended that it be inspected every two years to ensure proper function and performance.

- Eng 4 -

WHO blood pressure classifications
Standard for assessment of high or low blood pressure without regard to age, have been established by the World Health Organization (WHO), as shown in the chart.

SYSTOLIC (mmHg)

Reference European standard:
This products complies with EN instructions 93/ 42/EEC (Medical Device Directive) and with the following standards: EN 1060:1995 Noninvasive Sphygmomanometers, Part 1 General Requirements and EN 1060: 1997 Noninvasive Sphygmomanometers, Part 3 Supplementary Requirements for Electromechanical Blood Pressure Measuring Systems.

Hypertension (severe)

130 120
Hypertension (moderate) Grade 1 Hypertension (mild) High-Normal Normal Optimal

110 DIASTOLIC

Manufacturer:
Name: Living Science (Shenzhen) Co., Ltd. Address: Shun Mu Ku Road, Ping Hu County, Shenzhen, Long-Kang Town, China

European Representative:

Name: Innovative business promotion GmbH. Address: Huttenstrae 4 D-07743 Jena

Deutch

(mmHg)
Definition and Classification of Blood Pressure Lebels Note: When a patients systolic and diastolic blood pressure fall into different categories, the higher category should apply.

Franais

- Eng 5 -

DEVICE DESCRIPTION

1. Name of the parts

LCD display

CH 60 7

mmY S Hg.

ST AR T/
Setting button Mode button Recall memory button

mm A Hg.

/ M LSE IN

Y OR EM M

Wrist cuff

Start/Stop button

Batteries AAA 1.5V2

Carrying case

- Eng 6 -
2. Description of display symbols

Month Date Hour Minute

Afternoon time Measuring pressure symbol Blood pressure unit Battery weak displa y Error symbol Memory record Pulse rate Diastolic rate Systolic rate

Pulse symbol

- Eng 7 -

BATTERY REPLACEMENT

1. To use this unit, you must install batteries, If the battery mark is displayed, you must change both batteries. 2. Open battery cover as illustrated. Replace the two batteries, matching the (+) and () polarities on each battery with the polarity marks on the case. To take the batteries out easily, pull the transparent ribbon. 3. LR03 batteries or equivalent are suitable for this blood pressure monitor. All batteries used must be same type. Do not mix alkaline, standard (carbon-Zinc) or rechargeable (cadmium) batteries. Also, do not mix old and new batteries.

CLOCK MODE

1. Default time indicating state and selection of each mode
When the battery is installed, the time and date are set as follows. January 1 , 12:00:00 AM

2. Setting Date and Time

1) Press the Mode switch then Month starts flashing and press SET button to set the correct month. (Each time the Set switch is pressed, the value of the month is increased

- Eng 8 -

by one. The value of minute can be corrected in only the forward direction.) 2) Press the Mode switch then Date starts flashing. Press SET button to set the correct date. (Each time the Set switch is pressed, the value of the date is increased by one. The value of hour can be corrected in only the forward direction.) 3) Press the Mode switch then Hour starts flashing. Press SET button to set the correct date. (Each time the Set switch is pressed, the value of the Hour is increased by one. The value of hour can be corrected in only the forward direction.)

4) Press the Mode switch then Minute starts flashing. Press SET button to set the correct Minute. (Each time the Set switch is pressed, the value of the minute is increased by one. The value of Minute can be corrected in 12-hour format in only the forward direction.) 5) Press the mode switch to finish correction.

MEASUREMENT PROCEDURES

1. Attaching of wrist cuff
The blood pressure is measured at the wrist. Therefore, rolling up the sleeve is no longer necessary. The pressure cuff has integrated into the wristlet. Wind the wristlet around your left wrist. The wrist should be free. The display is at the inner of the wrist.

- Eng 9 -

Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately, it may display an error or abnormal values. Pull the wristlet tight and close the Burr closure. Wrist circumference: 13.5-19.5 cm.
Measurement Procedures for People With a Weak Pulse
Apply the middle part of the wrist cuff to the artery in the wrist to measure blood pressure.
2. To start the Measurement

CAUTION

Do not grasp the unit too tightly. Keep your left wrist relaxed during measurement period. Do not apply physical pressure against unit with wrist before or during measurement. All measurements must be performed while you are seated and with your left hand on a table held a level with your heart. Keep your body still and relaxed during measurement. 1) Press the Start/Stop switch. All display marks appear for approx. 1 second. All displays disappear and the time is updated. 2) The blood pressure measuring symbol will appear on the display and then the air pressure will automatically pump up to 195mmHg. 3) If blood pressure tends to be on the high level, the air pressure will automatically increase again to the required level for measurement.

- Eng 10 -

Do not move or talk while taking the blood pressure measurement. 4) When pressurization is completed, the automatic air release system will gradually reduce cuff pressure, and measuring mark Heartmark will flash on the display indication that measuring is in progress. 5) After taking blood pressure measurement, the systolic and diastolic pressure with pulse rate is displayed on the display for 1 minute. 6) Unless an error is generated, the measurement results are automatically stored in memory. Up to 99 sets of results can be stored in memory. * When there are already 99 sets of results in memory, the oldest one is automatically erased and overwritten with the newest. Display of the measurement result will continue until power is turned off.

3. Turn Power off

English Espaol Portugus Italiano Deutch
When the Start/Stop switch is pressed, the display will be changed over to the date/watch only indication and the power will be totally turned off approximately one minute later.
To discontinue a measurement for any reason, press the START/STOP switch. This causes the wrist cuff to deflate rapidly.
4. Automatic power-off function
If the unit is left on after measurement, an automatic power-off function turns the power off after approximately 1 minute. To continue measurement, press the START/STOP switch turning the unit on. After, wind the wristlet around your left wrist.

- Eng 11 -

5. Memory recall
You can recall stored data by pressing the Memory switch, except when performing a measurement. Up to 99 sets of measurement results are automatically stored in memory, and memory cell No. 1 is always used to store the oldest set of results. Press Memory switch, the memory cell number with the stored measurement results (Systolic / Diastolic and Pulse with Date/Time) are displayed for 1 minute. * Pressing Memory button, nothing will appear on the display if there is no data in the memory. If the Memory switch is pressed further, the old date are indicated in the order of the time series. Press Start/Stop switch to turn off the unit.

6. Memory clear function

To clear memory data, take out the two batteries at same time and then press the START/STOP switch for a while. All memory is erased.
Press the POWER/START switch to turn off.
To discontinue a measurement for any reason, press the POWER/START switch. This causes the wrist cuff to deflate rapidly.

- Eng 12 -

ERROR DESCRIPTION OF DISPLAY MARKS
DISPLAY MARK CONDITION / CAUSE Mark appears in the measurement condition and flashes when pulse is detected. Measuring Error Appears when the accurate blood pressure could not be obtained accurately. CORRECTIVE ACTION Measurement in progress. Remain still.
Press Start/Stop switch again and re-measure. Or check cuff if wrapped at the wrist or according to instructions. Check palm if exerting effort. Check if talking or moving during measurement. Check if posture is incorrect. Replace all batteries with new ones. Insert the batteries at paying close attention to the +/ directions.

Replace batteries

Appears when the battery voltage is excessively low or the positions of batteries are incorrect.
Measuring blood pressure symbol
Appears all the time until the measurement is completed.

- Eng 13 -

SPECIFICATIONS
Model Number Measuring Principle Measurement Localization Cuff Arm Circumference Range Measurement Range Accuracy Pressure Pulse Pressure Pulse Pressure Pulse LCD Indication Marks Viewing Size Digit Size CH607 Oscillometric System Left Wrist Arm Preformed cuff 13.5 to 19.5 cm 0 - 300 mmHg 40 - 199 Pulse / Min. 3mmHg 5% of reading Systolic Blood Pressure: 3 digits Diastolic Blood Pressure: 3 digits Alternatively Pulse Rate: 3 digits Measuring Exhaust Re-Measure Battery 38.0(H) 32.0(W) mm 9.5(H) 5.0(W) mm 4-switches (Start/Stop, Memory, Set, Mode) Automatic Inflation by Air Pump Automatic Air release control valve Quick Exhaust Valve 3 V DC 2 AAA Size Batteries 0.1 W Approx. 250 times measurement Approx. 3 min. (after activated) 20 Seconds a month, Full Automatic Calendar, Alarm 99 Memory (Date, Time, Blood pressure value, Pulse) 72(W) 70(D) 29(H)mm Approx. 140g including batteries. 10 to 40C 30 to 85%RH 20 to 50C 10 to 95%RH 2 AAA batteries, Instruction manual and Carrying case
LCD Switch Inflation Deflation Exhaust Rated Voltage Power Source Power Consumption Battery Life Automatic Power Off Function Clock Function Memory Function Dimensions Weight Operating Environment Storage Environment Accessories
Temperature Humidity Temperature Humidity
* Specifications and design may be changed without any notice in the event of improvementsbeing made.

- Eng 14 -

doc1

HEALTH CARE

HC200701

PRODUCT GUIDE 2007-2008

HEALTH CARE PRODUCTS

Digital Blood Pressure Monitors

Digital Thermometers

Ultrasonic Nebulizer

Digital pedometer

Body Fat Analyzer

071010 HC200701

Leading Technology for Humanity
Determined to develop as a corporation that offers new value for everyone everywhere through high-quality products and services. Citizen Systems is reinventing itself. Leading Technology for Humanity Our corporate slogan expresses the aspirations of every Citizen Systems employee, each of whom is striving to realize a shared ideal. We have superior miniaturization and refinement technologies cultivated by members of the Citizen Group. We have a desire to design products that are easy for anyone to use. And we have the skills required to pursue quality at every turn, combined with an unswerving commitment to manufacturing. We draw on these strengths to manufacture more advanced products for a wide range of fields, including health information management, information/entertainment and business information equipment. Our aim is to achieve advances in convenience, enabling people to lead more abundant and comfortable lives anytime and anywhere and to disseminate people-friendly technologies and services that help individuals lead healthier, more fulfilling lives. Leading Technology for Humanity We continue to take up new challenges with an eye on our customers and with these words in mind.
UD(UNIVERSAL DESIGN) is: The design of products and environments to be usable by all people, to the greatest extent possible, without the need for adaptation or specialized design. CITIZEN Health Care Products have been developed with the Universal Design concept in mind.

Digital Pedometer

Citizen Keyword of 21st Century Micro HumanTech Micro Citizen Technical Domain The precision and miniaturization technology that Citizen has developed in a long time; we use these technologies as nuclei, and always stick to the bases of production to make a contribution to the information revolution of 21st century in the field of precision and miniaturization. Human Citizen Technological Philosophy We provide products and develop technologies to communicate with people; the last consumer, and their healthy and hearty life, and to enable our life live together with the earth. We return to our establish basics known as customer principles in which our hope is to make a contribution to people's life in every where in the world by making products that is familiar and loved by citizens. Tech Citizen Technological Method The professionalism in production that supports the reliance of Citizen. We make a fusion for all technologies such as the precision processing technology, the measurement technology, energy saving technology and the production technology with beautiful and simple designs to create products that is reliable and fascinating. We have a strong belief that the technology fused with sense and knowledge will make people happy.

Model Index

Upper Arm / Full Automatic

What is blood pressure?

The heart is a pump that circulates blood throughout your body. Blood is pumped from the heart at a constant pressure into arteries. This pressure is called the arterial blood pressure and represents, in general terms, your blood pressure. Blood pressure is indicated by several kinds of pressures, including the systolic pressure that occurs when the heart pumps blood and the diastolic pressure that occurs when blood returns to the heart.
CH-463E Cuff to go easy and accurate
Full automatic Blood Pressure Monitor 60 memories function Cuff to go easy and accurate Easy-to-read LCD display Easy to store integrated cuff holder Large buttons for easy opperation Automatic power off function Simultaneous blood pressure and pulse reading AC adapter is optional (AC-230CZ) SPECIFICATIONS
Your blood pressure changes all the time.
Your blood pressure differs according to your age, gender and a range of other factors. It is likely to be affected by your biorhythm during the day and by your posture, physical activities, mental activities, level of stress and even by the air temperature. The blood pressure of a healthy person generally varies within a day.

Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optional AC/DC adapter 6VDC, 1A Battery life: Manganese battery: Approx. 150 times Alkaline battery: Approx. 500 times Rated voltage: DC6V 3W : Direct Current Outside dimensions: 112mm W 148mm D 152mm H Weight: Unit: Approx. 520g without batteries Cuff: Approx. 250g

How to operate

Blood pressure classifications
The figure left shows the blood pressure classifications under the WHO standards. (Taking measurements while sitting in the hospital)
Slip the cuff around your left arm through so that the blue marker is located in the center of your arm.
To wrap up the cuff, turn the dial clockwise until the click idles.
Press the "START/STOP" switch to start measurement.
Press the release lever (marked "PUSH" ) to let free the cuff.
Function mark explanation
CH-462Efull automatic One touch operation,
Blood Pressure Monitor 60 memories function Easy-to-read LCD display Easy to store integrated cuff holder Large buttons for easy opperation Automatic power off function Simultaneous blood pressure and pulse reading AC adapter is optional (AC-230CZ) SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optional AC/DC adapter 6VDC, 0.6A Battery life: Manganese battery: Approx. 150 times Alkaline battery: Approx. 500 times Rated voltage: DC6V 3W : Direct Current Outside dimensions: 112mm W 148mm D x152mm H Weight: Unit: Approx. 520g without batteries Cuff: Approx. 140g
ACCUTUBE& CH-462E Applicable only to CH-461C

SPECIFICATIONS

Measurement Localization: Arm Circumference range: Weight: Adaption: Upper Arm 20 32cm Approx. 250g CH-462E, CH-461C

Adaption

CH-461C

CH-462E

CH-461C automatic One touch operation, full
Blood Pressure Monitor 7 memories function Easy-to-read LCD display Large buttons for easy opperation Automatic power off function Simultaneous blood pressure and pulse reading AC adapter is optional (AC-230CZ) SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optional AC/DC adapter 6VDC, 0.6A Battery life: Manganese battery: Approx. 200 times Alkaline battery: Approx. 700 times Rated voltage: DC6V 3W : Direct Current Outside dimensions: 112mm W 76mm H 145mm D Weight: Unit: Approx. 340g (without batteries) Cuff: Approx. 140g

CH-406D Pressure One touch operation Blood
Monitor with Time & Date 48 memories function Simultaneous blood pressure and pulse reading Easy-to-read LCD display Automatic power off function AC adapter is optional (AC-406EU/US) SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optional AC/DC adapter 6VDC, 1A Battery life: Alkaline battery: Approx. 250 times Rated voltage: DC6V 6W : Direct Current Outside dimensions: 145mm W 68.8mm H 105mm D Weight: Unit: Approx. 300g without batteries Cuff: Approx. 140g
CH-437C automatic One touch operation, full
Blood Pressure Monitor 7 memories function Easy-to-read LCD display Easy to store integrated cuff holder Automatic power off function Simultaneous blood pressure and pulse reading AC adapter is optional (AC-230CZ) SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optional AC/DC adapter 6V 4W Battery life: Manganese battery: Approx. 200 times Alkaline battery: Approx. 700 times Rated voltage: DC6V 4W : Direct Current Outside dimensions: 95mm W 130mm H 118mm D Weight: Unit: Approx. 320g without batteries Cuff: Approx. 160g
CH-403C Compact automatic inflation
Blood Pressure Monitor with 7 memories 7 memories function Easy-to-read LCD display Compact & light weight Automatic power off function Automatic measuring function AC adapter is optional (AC-230CZ) SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Optinal AC/DC adapter 6V DC, 1A Battery life: Manganese battery: Approx. 200 times Alkaline battery: Approx. 400 times Rated voltage: DC6V 4W : Direct Current Outside dimensions: 135mm W 51mm H 130mm D Weight: Unit: Approx. 290g without batteries Cuff: Approx. 150g
CH-485E Oval-shaped unique design,
concept of Universal Design 30 memories function Full auto calendar alarm clock Easy-to-store integrated cuff holder Easy-to-read LCD display Large buttons for easy opperation Automatic power off function Battery indicator Simultaneous blood pressure and pulse reading
CH-432B automatic One touch operation, full
Blood Pressure Monitor Memory recall function Easy-to-read LCD display Full Automatic cuff inflation Automatic measuring function Automatic power off function SPECIFICATIONS

Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Battery life: Manganese battery: Approx. 200 times Alkaline battery: Approx. 700 times Rated voltage: DC6V 4W : Direct Current Outside dimensions: 129mm W 55mm H 122mm D Weight: Unit: Approx. 230g without batteries Cuff: Approx. 150g
Full auto calendar alarm clock
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Battery life: Alkaline battery: Approx. 500 times Rated voltage: DC6V 4W : Direct Current Outside dimensions: 129mm W 152mm H 121mm D Weight: Unit: Approx. 400g without batteries Cuff: Approx. 150g
Upper Arm / Semi-Automatic
CH-311B inflation Compact palm top manual
Blood Pressure Monitor Memory recall function Simultaneous blood pressure and pulse reading One handed operation Easy-to-read LCD display Automatic power off function SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AAA size 2 Battery life: Manganese battery: Approx. 700 times Rated voltage: DC3V 0.1W : Direct Current Outside dimensions: 66.5mm W 161.5mm H 44.5mm D Weight: Unit: Approx. 110g without batteries Cuff: Approx. 150g
CH-302B Compact manual inflation
Blood Pressure Monitor Memory recall function Easy-to-read LCD display Compact & light weight Automatic power off function SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: 6F22/9V 1 Battery life: Manganese battery: Approx. 400 times Rated voltage: DC9V 0.1W : Direct Current Outside dimensions: 85mm W 35mm H 120mm D Weight: Unit: Approx. 110g without battery Cuff: Approx. 150g Pumping bulb unit: Approx. 40g
CH-308B inflation Easy operation manual
Blood Pressure Monitor Memory recall function Large LCD display Large button Automatic power off function SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AA size 4 Battery life: Manganese battery: Approx. 1000 times Rated voltage: DC6V 0.1W : Direct Current Outside dimensions: 123mm W 44mm H 95mm D Weight: Unit: Approx. 120g without batteries Cuff: Approx. 150g Pumping bulb unit: Approx. 40g
CH-671F Wrist measuring Automatic

Blood Pressure Monitor with Time & Date and Monthly average function 90 memories function Monthly average function Simultaneous blood pressure and pulse reading Soft cuff for comfortable use Compact design for easy to carry Automatic power off function With compact storage case SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; 0 280mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AAA size 2 Battery life: Alkaline battery: Approx. 300 times Rated voltage: DC3V 1W : Direct Current Outside dimensions: 59mm W 81mm H 24mm D Weight: Approx. 100g without batteries
CH-656C Slim and light-weight
Wrist measuring Automatic 7 memories function 7 memories function One touch full automatic operation Soft cuff for comfortable use Compact design for easy to carry Automatic power off function With compact storage case SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AAA size 2 Battery life: Alkaline battery: Approx. 400 times Rated voltage: DC3V 1W : Direct Current Outside dimensions: 67mm W 70mm H 21mm D Weight: Approx. 100g without batteries
CH-606 Wrist measuring Automatic
Portable Blood Pressure Monitor with Time & Date 48 memories function Simultaneous blood pressure and pulse reading With time, day and date functions One touch automatic operation Easy-to put on preformed cuff With compact storage case SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AAA size 2 Battery life: Alkaline battery: Approx. 250 times Rated voltage: DC3V 1.8W : Direct Current Outside dimensions: 72mm W 70mm H 29mm D Weight: Approx. 100g without batteries
CH-607 Wrist measuring Automatic
Portable Blood Pressure Monitor and Time & Date 99 memories function Simultaneous blood pressure and pulse reading With time, day and date functions One touch automatic operation With compact storage case SPECIFICATIONS
Measurement System: Oscillometric method Measurement range: Pressure; mmHg Pulse; pulse/min Accuracy: Pressure; 3 mmHg, Pulse; 5 % Power source: AAA size 2 Battery life: Alkaline battery: Approx. 250 times Rated voltage: DC3V 1.8W : Direct Current Outside dimensions: 72mm W 70mm H 29mm D Weight: Approx. 110g without batteries

CH-605 Wrist measuring Automatic
Portable Blood Pressure Monitor 48 memories function Simultaneous blood pressure and pulse reading Large size LCD display One touch automatic operation Easy-to put on preformed cuff With compact storage case SPECIFICATIONS

Comparison

Automatic Upper Arm Automatic Upper Arm

Products

Model Outside dimensioms Weight (without batteries) 112

CH-463E 148 152mm

CH-462E 152mm

CH-461C 145mm 129

CH-432B 55 122mm 129

CH-485E 152 121mm 145

CH-406D 68.8 105mm
CH-437C 118mm Unit: Approx. 320g, Cuff: Approx. 160g Soft cuff 7 Memory 135

CH-403C 51 130mm

Unit: Approx. 520g, Cuff: Approx. 250g Pro adjust cuff 60 Memory
Unit: Approx. 520g, Cuff: Approx. 140g Soft cuff 60 Memory
Unit: Approx. 340g, Cuff: Approx. 140g Soft cuff 7 Memory
Unit: Approx. 230g, Cuff: Approx. 150g Soft cuff Memory recall -
Unit: Approx. 400g, Cuff: Approx. 150g Soft cuff 30 Memory
Unit: Approx. 300g, Cuff: Approx. 140g Soft cuff 48 Memory
Unit: Approx. 290g, Cuff: Approx. 150g Soft cuff 7 Memory -
Cuff Memory Display simultaneously Auto measuring High-speed measurement Auto power off Storage Display Battery life Power source Option (AC / DC adapter) Silent Page
Alarm & Clock 500 times AA size 4 Alarm & Clock 500 times AA size times AA size 4
700 times AA size 4 Alarm & Clock 500 times AA size 7 4
250 times AA size times AA size 4

400 times AA size 4

Manual Upper Arm
Model Outside dimensioms Weight (without batteries) 66.5

CH-311B 44.5 161.5mm

CH-308B 95mm

CH-302B 120mm

Model Outside dimensioms Weight (without batteries) Cuff Memory Display simultaneously Auto measuring Auto power off Time Battery life 59

CH-671F 81 24mm 67

CH-656C 70 21mm

CH-70 29mm 72

CH-29mm 72

CH-29mm

Unit: Approx. 110g, Cuff: Approx. 150g Soft cuff Memory recall
Unit: Approx. 120g, Cuff: Approx. 150g Pumping bulb unit: Approx. 40g Soft cuff Memory recall -
Unit: Approx. 110g, Cuff: Approx. 150g Pumping bulb unit: Approx. 40g Soft cuff Memory recall -
Approx. 100g Soft cuff 90 Memory
Approx. 100g Soft cuff 7 Memory -
Approx. 110g Hard cuff 99 Memory
Approx. 100g Hard cuff 48 Memory
Cuff Memory Display simultaneously Auto measuring High-speed measurement Auto power off Battery life Power source Page
300 times AAA size times AAA size times AAA size times AAA size 2

250 times AAA size 2

700 times AAA size 9 2

1000 times AA size 9 4

400 times 6F22/9V 10 1

Power source Case Page

CT461C CT461F Reliable and accurate
CELSIUS (C) FAHRENHEIT (F)
CT513W resistant, Fully washable, water

always keeps clean

CELSIUS (C)
General purpose use Auto memory recall of last reading Buzzer notices 3-Digits display Auto power off SPECIFICATIONS
Measuring method: Temperature peak hold thermometer Measuring range: 32.0C 44.0C 89.6F 111.2F Accuracy: Celsius 0.1C 35.5 42.0C Fahrenheit 0.2F 95.9 107.6F Display: Liquid crystal display LCD 3 digits with decimal point C F , battery weak mark and memory mark Battery : DC1.5V Micro Alkaline Battery; LRBattery life : Approx. 1.5 year If used 10 minutes a day Unit size : Approx. 130.8mm L 18.2mm W 11.6mm H Weight: Approx. 11.2g Including battery
General purpose use Water resistant & fully washable Using antibacterial material for cases Auto memory recall of last reading Buzzer notices 3-Digits display Auto power off SPECIFICATIONS
Measuring method: Temperature peak hold thermometer Measuring range: 32.0C 42.0C Accuracy: 0.1C 35.5 42.0C Display: Liquid crystal display LCD 3 digits with decimal point C, memory mark M Battery mark Battery : DC1.5V Micro Alkaline Battery; LRBattery life : Approx. 3 years If used 3 times a day, for 10 min. each time Unit size : Approx. 129mm L 17mm W 8mm H Weight: Approx. 10g Including battery
CT561C CT561F resistant Fully washable water

FAHRENHEIT (F)

CT422water resistant, Fully washable,
always keeps clean General purpose use Water resistant & fully washable Using antibacterial material for cases Auto memory recall of last reading Buzzer notices 3-Digits display Auto power off SPECIFICATIONS
Measuring method: Temperature peak hold thermometer Measuring range: 32.0C 42.9C Accuracy: 0.1C 35.5 42.0C Display: Liquid crystal display LCD 3 digits with decimal point C, memory mark M Battery mark Battery : DC1.5V Micro Alkaline Battery; LRBattery life : Approx. 3 years If used 1 times a day, for 10 min. each time Unit size : Approx. 128mm L 18mm W 8mm H Weight: Approx. 10g Including battery
General purpose use Water resistant & fully washable Auto memory recall of last reading Buzzer notices 3-Digits display Auto power off SPECIFICATIONS
Measuring method: Temperature peak hold thermometer Measuring range: 32.0C 44.0C 89.6F 111.2F Accuracy: Celsius 0.1C 35.5 42.0C Fahrenheit 0.2F 95.9 107.6F Display: Liquid crystal display LCD 3 digits with decimal point C F , battery weak mark and memory mark Battery : DC1.5V Micro Alkaline Battery; LRBattery life : Approx. 1.5 yeas If used 10 minutes a day Unit size : Approx. 130.8mm L 18.2mm W 11.6mm H Weight: Approx. 11.2g Including battery

Coming soon

CT830 Ear Thermometer Multi-function Digital
9 memories of ear temperature Ear temperature mode or surface temperature mode available Celsius or Fahrenheit mode available No need to use probe cover Stop-watch for pulse counting SPECIFICATIONS
Measuring range: For ear temperature mode; 34.0C 42.2C 93.2 108F For Material surface temperature mode; -22 80C -7.6 176F Accuracy: For ear temperature mode; 0.2C 0.4F for temperatures 35.5 42.0C 95.9 107.6F , 0.3C 0.5F for other ranges For Material surface temperature mode; 0.3C 0.5F for temperatures 22 42.2C -7.6 108F for other ranges. 4% or 2C 4F , whichever greater Display: Liquid crystal display LCD 3 digits with decimal point C or F Battery : DC3V Lithium Manganese Dioxide Battery CRBattery life : 3,000 consecutive measurements Unit size : Approx. 115mm L 37mm W 29mm H Weight: Approx. 60g Including battery
CT915 Digital graphic thermometer
31 readings are displayed by graph Up to 120 reading can be recorded automatically Basal Body Temperature can be easily measured Alarm to notify measurement time is available Using antibacterial material for cases SPECIFICATIONS
Measurement System: Temperature peak hold thermometer Measurement range: 32.00C 42.00C Unit: 0.01C Accuracy: 0.05C 35.00 38.00C, other 0.1 Display: Display in value 4-digit LCD, Display in graph Bar graph of data of 31 days Battery: DC3V Lithium Manganese Dioxide Battery CRBattery life: Approx. 1year If used 1 time a day Unit size: Approx. 100mm W 90mm H 23.5mm D Probe cord: Approx. 400mm Weight: Approx. 100g Including battery
CT810 method for Twin Thermistors
Easy and Quick measurement !!
High Accuracy and Stable Measurement No need to use a probe cover Antibacterial material and water resistant construction For 2 seconds measurement time Auto Power OFF and 3,000 times use with one battery(LR44) SPECIFICATIONS
Measuring range: 32.0C 42.0C Accuracy: 0.1C 36.0< T< 39.0C = = Measuring temperature at 23.0C 0.2C T<36.0C, T>39.0C Measuring temperature at 23.0C Display: Liquid crystal display LCD 3 digits with decial point C, battery weak mark Battery : DC1.5V Micro Alkaline Battery LR44 Battery life : Over 3,000 consecutive measurements Unit size : Approx. 131mm L 37mm W 25mm H Weight: Approx. 45g Including battery
Model Unit Size (Approx.) Weight

CT461C / CT461F

CT561C / CT561F 129

CT513W 17 8mm

CT18 8mm 115

CT29mm

CT37 25mm 100

CT23.5mm

130.8 18.2 11.6mm 130.8 18.2 11.6mm Approx. 11.2g (Including battery) 3 Digits Approx. 11.2g (Including battery) 3 Digits -
Comes with a compact carrying case.
Approx. 10g (Including battery) 3 Digits
Approx. 60g (Including battery) 3 Digits -
Approx. 45g (Including battery) 3 Digits
Approx. 100g (Including battery) 4 Digits
Display Aniti Bacterial Water Resistant Buzzer Auto power off Memory recall Battery life Power source Page

Caution

Measurement result with this unit may be different from a result by other type of thermometers due to a different measuring place.
1.5 year LR1 1.5 year LRyears LRyears LRtimes CR3000 times LR1

1 year CR2032 18

CUN60 light in weight with Handy design and
rechargeable battery pack Handy design with built-in detachable rechargeable battery pack, compact and light-weight Easy to use uses water as ultrasonic conducting medium, no gel is required Silent operation thanks to the ultrasonic vibration technology 3-speed nebulization rate control provides optimal treatment for different density Built-in timer automatically shuts off after 10 minutes use SPECIFICATIONS
AC100V, 50/60Hz AC220-240V, 50/60Hz Power consumption: Approx.10W Ultrasonic Frequency: 2.5 MHz Nebulization rate: 3-speed adjustable Particle size: 5 umMMAD Medication cup capacity: Max. 8 ml. Auto shut-off timer: Approx. 10 min Dimension: 88mm W 143mm H 53mm D Weight: Approx. 350g Including rechargeable battery-pack Accessories: Nose piece. Mouth nozzle. Extension tube. Adult & child masks. AC adapter. Medication cup 15 pcs. Soft carrying case. Power:
TW300life For your healthy
Easy to read large Display Calorie consumption chart Sensitivity adjustment switch SPECIFICATIONS
Step detection system: Display: Steps: Power source: Battery life: Dimension: Weight: Pendulum mechanism Liquid crystal digital steps Type LRApprox. 2 years 55mm W 35.5mm H 12.8mm D Approx. 21g without batteries

Totally Portable !!

BM100life For your healthy
The body conditions up to 15 persons can be registered The obesity is displayed at four levels Large LCD Display SPECIFICATIONS
Measuring range: Settable height: Settable weight: Settable age: Power source: Battery life: Dimension: Weight: 5% 50% Measuring unit: 0.1% 100 200cm or ft-in 10 150kg or 1:9 23:9 st.lb) or lb age AAA size 4 Approx. 1year 265mm W 71mm H 125mm D Approx. 300g without batteries
Digital Pedometer / Body Fat Analyzer

Easy Operation !!

Unit Model Index Dimension(W H Dmm) Master Carton M3 Kg Weight(g) Packed Q'TY Jan Code Page
CH-463E CH-462E CH-461C ACCUTUBE CH-406D CH-437C CH-485E CH-403C CH-432B CH-311B CH-308B CH-302B CH-671F CH-607 CH-656C CH-606 CH-605 Wrist Type Wrist Type Wrist Type Wrist Type Wrist Type 195.0 170.0 150.0 175.0 145.0 95.0 129.0 135.0 129.0 66.5 123.0 85.0 59.0 72.06 70.0 72.0 72.0 157.0 135.0 120.0 145.0 68.8 130.0 152.0 51.0 55.0 161.5 44.0 35.0 81.0 70.0 67.0 70.0 70.0 203.0 195.0 130.0 165.0 105.0 118.0 121.0 130.0 122.0 44.5 95.0 120.0 24.0 29.0 21.0 29.0 29.0 1219.0 972.0 753.0 385.0 300.0 320.0 400.0 290.0 230.0 110.0 120.0 110.0 100.0 110.0 100.0 100.0 100.0.079 0.102 0.064 0.096 0.038 0.036 0.044 0.032 0.065 0.056 0.038 0.030 0.033 0.027 0.028 0.027 0.027 16.3 23.5 17.2 11.8 10.0 9.0 9.7 8.0 14.0 11.5 7.0 5.5 8.0 6.5 6.5 6.5 6.12
CT461C CT461F CT561C CT561F CT513W CT422 CT830 CT810 CT915 130.8 130.8 130.8 130.8 129.0 129.0 115.0 131.0 90.0 18.2 18.2 18.2 18.2 17.0 17.0 25.0 25.0 100.0 11.6 11.6 11.6 11.6 8.0 8.0 37.0 25.0 23.5 11.2 11.2 11.2 11.2 10.0 10.0 60.0 45.0 100.0.047 0.047 0.047 0.047 0.045 0.045 0.071 0.098 0.052 11.0 11.0 11.0 11.0 9.7 9.7 10.2 17.0 15.18
CUN60 88.0 143.0 350.0 350.0.050 14.19
TW300 80.0 137.0 26.0 44.0.058 820.20
BM100 265.0 71.0 300.0 300.0.088 13.20

 

Tags

Pixon Urei 525 UF-E1 2 CV DV7732NSC 50PQ30 SDM-P234 3700GX Review VPC-HD700 Cooker DVP3015K DCP-7025 5200-701 UX-G4 MHC-GNZ55D KDC-MP522 300FB P4B533-VM Elefun 6347dwde KX-TG6073 S1410 ZN200 TK-862G ZKT663LX 14A ER8260D-00 All-IN-ONE Des Rois L1740PQ KAC-5203 56609 XV-DV525 Iii-morrowind Alliance PSC 2150 B2175 Power F5 PKS 40 KR753K DCS-900 Series Armada-2004 MD 2998 Samsung R730 SE1453B 2 5 VX-127 WM901ECO CMT-GP5 2410-404 SY-20 DS207 CDI210 Centauri DM6 KIT CDX-M7850 M1201 31-20 TI-68 Auto-vice City ICD-CX50 WD-10170ND DMC-FZ4 SLK350 XVS1100 DST450 PD-H300mkiii BSG71370UC Elro C950 KCA-IP300V LAC5700R DM-SE9 XEC500 IC-F3-S Volleyball Quad 303 3245C DV203AES-XAC SGH-M300N Electrolux Z65 SA-DP1 NAD C541 Av-14 DTH6000 MHC-RG70AV Roland NS-2 Stone Plus M4N78 PRO IP-423-WEB Omnibook 2100 SLT-A55 Dvdr3455H 97 HUB Manu MC-E468 Omniswitch 9000 Yamaha SK20 Factor PC Lifestyle V35 Bass800 DCR-TRV20E

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 