Reviews & Opinions
Independent and trusted. Read before buy Clivet Wsat-2!

Clivet Wsat-2


Bookmark
Clivet Wsat-2

Bookmark and Share

 

Clivet Wsat-2About Clivet Wsat-2
Here you can find all about Clivet Wsat-2 like manual and other informations. For example: review.

Clivet Wsat-2 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Clivet Wsat-2 please write about it to help other people.
[ Report abuse or wrong photo | Share your Clivet Wsat-2 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Clivet Wsat-2, size: 2.7 MB

 

Clivet Wsat-2

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

feeling cool
WSAT-2 SERIES CHILLERS from 200-1500 KW
The CLIVET chillers WSAT-2 series have air cooled condenser with axial low speed fans. They are equipped with semi-hermetic single screw compressors using R-407c ecological refrigerant agent. The electrical circuitry , the control unit equipped with microprocessor and the LCD display are all integrated under the chiller weatherproof casing. The case is made of galvanised steel and protected by a thermic treated resin, painted in electrostatic field, therefore is included in IP 45 protection class. The WSAT-2 chillers are configurable with 2,3 or 4 independent refrigerant circuits for redundancy. Each circuit is equipped with his compressor, expansion valve, solenoid valve, drying filter with detachable core, closing valve, lubricating device, injection circuit, safety valve and manometers for high and low pressure.
R-407c ECOLOGICAL REFRIGERANT AGENT

LE NG HT

DEUTSCHER AKKREDITIRUNG RAT E N U N I - I S O 0 1

DAIKIN

SINGLE SCREW COMPRESSOR

EN UNI - ISO 9001

NATIONAL ACCREDITA TIONS OF CERTIFICATION BODIES
The single screw compressor developed by DAIKIN uses ecological refrigerant agent and, beside the high tecnology level it has a compact, simple and solid construction. Due to the lack of valves and critical reciprocity elements the compressor has an increased resistance at liquids pressure shocks and therefore results a high reliability. Th compressor has a perfect balance between the axial and radial forces due to the symmetrical compression with a single rotor and 2 gears. The internal contact pressure is very low and the gears made of a special composed material determine the decrease of detrition and energy loss. The lubricating pump is unnecessary because the compressor is cooled by the freons circulation. The single screw design (without primers and alternate movements) determines a very low detrition and noise level. The service interventions for oil changing are necessary only after 40.000 hours of continuous operation.

HEIGHT (H)

ORDERING CODE:

WSAT-2

SERIE WSAT-2

R-407C refrigerant

APPROVALS:
C= CLIVET - internal I= ISPEL - Italy D= TUV - Germany S= S.A. - Sueden F= SDM - France E= MIE - Spain T= TTK - Finland

VERSIUNI

S = Standard R = Total heat recovery D = Partial heat recovery B = Brine Chiller
TOTAL COMPRESSORS POWER (HP)

CONFIGURATION

ST = Standard LN = low noise

APLICATIONS:

T = temperate climate H = high efficiency

NUMBER OF COMPRESSORS

CHILLER CLIVET WSAT Cooling power (1)
Compressors electrical power (1)
2.90 2.100 2.110 2.125 2.140 2.155 2.170 2.200 2.230 2.260 2.280 2.300 2.330 2.kW A A 42.139 46.8 35.2 30.149 49.7 34.9 28.159 53.3 34.6 33.180 58.22.40.4 25.220 71.6 44.6 31.249 82.8 51.8 32.278 92.5 55.8 32.63.4 32.67.2 31.321 750
Max current load (2) Max start current (2)

65.5 31.64 31.76 69

Max total electrical power(3) kW
Water flow (1) Air flow Static pressure (1) Noise level ST(4) Noise level LN(4) Noise level EN(4) Total weight

Dimensions L x W x H

m /s 24.9 kPa dB(A) dB(A) dB(A) 32.73 67

Kg 3733

mm 3950x2040x2104

4880x2326x2443

3950x2326x2443

5900x2326x2443

CHILLER CLIVET WSAT

Cooling power(1)

3.390 3.410 3.430 3.450 3.480 3.510 3.540 4.580 4.600 4.630 4.660 4.690 4.720

kW A A

146 89.4 33.7044

33.7324

32.7790

31.8788

30.78 72

30.79 73

29.79 73

Water flow (1) Air flow Static pressure
m3/h m /s kPa dB(A) dB(A) dB(A) Kg
Noise level ST(4) Noise level LN(4) Noise level EN(4) Total weight
Dimensions L x 2326 x 2443
SUPPLY POWER STANDARD 400V /3~/ 50 Hz
(1) test conditions: water evaporating at 12/7C -room temp 35C (2) data for the entire unit (3) in maximum admisable conditions (4) the noise level ins measured at 1m distance from the unit placed in open space The manufacturer reserves his right to do small changes of nominal parameters
EVERY CHILLER IS TESTED BEFORE DELIVERY IN SPECIALS STANDS, IF THEY ARE OPERATING AT THE NOMINAL PARAMETERS FROM THE TABEL ABOVE.

DEALER:

MANUFACTURER:
CLIVET s.p.a. - Z.I. 32030 VILLAPAIERA - FELTRE(BL) Italy

doc1

CLIVET PRODUCTS RANGE

COOLING STATIONS - CHILLERS

AIR COOLED WATER CHILLER

External mounting Internal mounting
Pumping station with storage tank

LARGE SIZE INSTALATION

WSAT-2 2.90 - 4.720 WSAT-3 2.90 - 4.480 Cooling capacity: 198 - 1482 kW
WRA-2 2.70 - 2.120 Cooling capacity: 140 - 226 kW
WATER COOLED WATER CHILLER
Air cooled condenser External mounting CRV 225 - 514 Internal mounting and remote condenser MSE-2 2.90 - 4.720 Cooling capacity: 222 - 1565 kW GPM 60 - 99 Cooling capacity: 1200 - 2400 L
WRH-2 2.70 - 4.240 Cooling capacity: 178 - 1666 kW
COMMERCIAL & SERVICE BUILDINGS
External mounting WSAT-- 242 WSAT-- 604
Cooling capacity: 18 - 151 kW
Internal mounting WRA 71 - 242 WRA 292 - 604
Cooling capacity: 22 - 151 kW
Air cooled condenser External mounting WRH 102 - 362
Cooling capacity: 32 - 127 kW
Internal mounting and remote condenser ME 71 - 362
Cooling capacity: 18 - 130 kW

CE 51 - 201

GP- 12
Cooling capacity: 300 - 1000 L

RESIDENTIAL APPLICATIONS

External mounting WSAT-- 71
Cooling capacity: 4 - 16 kW
Internal mounting WRA/WRN 21 - 51 Cooling capacity: 6 - 18 kW
Air cooled condenser External mounting WRH 21 - 51
Cooling capacity: 5 - 18 kW
Internal mounting and remote condenser ME 21 - 51

CE 25 - 51

GPA 65 - 150
Cooling capacity: 65 - 150 L

 

Tags

DKE9465EUC Yamaha TX1P TDM-NC1 TA-FA1200ES GW611 Dtca7 Redefined L227WTP-PF LS-L1210CL Conquerors Abit BG7 ICF-SW35 STR-DN1010 DPF-D82 ICA-107 KDL-40E5520 SX200 CMT-DH5BT SC-HT400 X6100 CVA-1003E V-1065A Composio RTS MD150 Fostex PM-2 DCR-SR68E SCH-U490 ZJD1219 VR-120 70W-QD KR-5200 Chorus Gr-dx35 GR-DVM96u-gr-dvm96 Model TWO Miele S548 Phone 7911 Milestone 2 HD 8KG Yamaha P60 Ultra Zoom YST-SW215 FAX-817 AVH-P4250dvd-avh-p3250dvd-avh-p3250BT KX-TG1100NL Video S-W110s-K YP-K5JQB Review 3210 E RB-1562 SP-1203N Xtc 1400 DCR-TRV255E A3000 Hkts 18 PP46D Graphire HD 25 Flash SD-T50w1 Individual Workstation Revolution 2000 1711 VPN LG MG66 Le32R52B Dkvm-2 XD-352 5200N HP6503 Geovid 56 Easy Gprs Campus 1200XL SD-206 GER Doro 513C MRT-3 L1753TR-SF Pulsar 260 SU-X920D Wintv-PVR Valencia MP36 32LG3300 ES-8044 MF4010 Pfaff 97 Drive Compact 350 CTM-1503R RQ-SX41 Fisio 822 GCS1742 C525BEE WMR918 LX-1050 DMC-FZ4 Dslr-A100 TX-L32c10P Urc4041 HFC141

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 