Reviews & Opinions
Independent and trusted. Read before buy Daikin BRC1A61!

Daikin BRC1A61

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Daikin BRC1A61, size: 963 KB
Instruction: After click Download and complete offer, you will get access to list of direct links to websites where you can download this manual.

About

About Daikin BRC1A61
Here you can find all about Daikin BRC1A61 like manual and other informations. For example: review.

Daikin BRC1A61 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Daikin BRC1A61 please write about it to help other people.

 

[ Report abuse or wrong photo | Share your Daikin BRC1A61 photo ]

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc1

Can Be Installed for Each Floor
Since the external hydrostatic pressure of the outdoor unit fan motor is 6 mm H2O, an outdoor unit can be placed on each floor using short-discharge ductwork.
* Refer to pages 23 and 24 for details about Advanced Controllers.
Unique piping and wiring systems and lightweight, compact indoor units make it possible for just a few people to install a VRV system quickly and easily. The Auto Address Setting function and the Auto Check function for piping and wiring errors allow anyone with just the ability to install regular direct expansion type air conditioning equipment to perform a highly reliable installation.

Super Wiring System

A Super Wiring system is used to enable the shared use of the wiring between indoor and outdoor units and the central control wiring. A high-level central control system can be achieved via a relatively simple wiring operation. Even when retrofitting with a central control system, all that is required is to connect the central control unit to the outdoor units.

Conventional

Super wiring system

Outdoor unit

Reduced Piping and Cost
Daikin's advanced REFNET piping system makes installation easy. Only two* main refrigerant lines are required in one system, and the strainers, stop valves, two-way and three-way valves, used in conventional water piping systems are not required. Thanks to the REFNET piping system and electronic expansion valves, imbalances in refrigerant flow between units is greatly reduced even though small-diameter piping is used. The smalldiameter piping is also easy to handle and requires less piping shaft space. (* Three in the case of heat recovery type.)
Central remote controller

Indoor unit

Auto Address Setting Function
The address of each indoor unit is set automatically at the same time they are connected, thus eliminating the need to manually set each address. Address setting for central control can be performed easily from the remote controller of an indoor unit.

Sequential Starting

By employing D -net, systems on the same power line will be started sequentially. This holds down the starting current, allowing the capacities of breakers to remain small (possible up to 100 HP).
Four-Way Wiring and Piping Connection

REFNET Joint ATTACHED INSULATORS for REFNET Joint
The REFNET Joint and REFNET Header (both optional) reduce the amount of work involved in installation and increases the reliability of the system.
REFNET Header for REFNET Header
Wiring can be fed from the front panel, both left and right side panels or bottom panel of the outdoor unit. Piping can be fed from 4 directions, front, both left and right or bottom of the outdoor unit.
These features increase installation flexibility, minimizing the space required for installation and simplifying maintenance of the wiring and piping.

Front Bottom Left Right

Simple Wiring
Two-wire multiplex transmission system makes it possible to connect multiple indoor units to one outdoor unit with one 2-core wire, thus simplifying the wiring operation.
Power supply Front Bottom
Note: Refer to engineering data for details of the exterior design of the outdoor unit and the locations of connection points for piping and wiring.
Check Function for Connection Errors of Wiring and Piping
Twin cable multiplex transmission system
Mistakes in piping or wiring in the system can be checked via lamps on the printed circuit board of the outdoor unit.
Self-Diagnosis Function for Efficient Servicing and Maintenance
The self-diagnosis function detects malfunctions in major locations in the system and displays the type of malfunction and location. This allows servicing and maintenance to be performed more efficiently.
The VRV system is an advanced system that offers convenience and comfort for end users.
Precise Room Temperature Control
Electronic expansion valves respond to changes in load in indoor units and continually control the flow rate of refrigerant. In this way, the VRV system maintains a nearly constant room temperature without the typical temperature changes that occur with a conventional ON/OFF control system. The extremely refined PID control maintains the room temperature within 0.5C of the set temperature. (Cooling)
VRV System (DAIKIN PID Controls) ON/OFF controlled air conditioner (2.5 HP)
Operation lamp Blinking Blinking Blinking
Inspection display Blinking Blinking Blinking
Unit No. Blinking Blinking Blinking
Malfunction code A1 A9 U4
Nature of malfunction Indoor unit : Print circuit board error Indoor unit: Electronic expansion valve drive unit (YIE) error Transmission error : Indoor unit Outdoor unit Outdoor BS unit ; BS unit

Suction air temp.

5 HP Outdoor Unit
100% Compressor Capacity Control Compressor Capacity Control
8, 10, 12 HP Outdoor Unit
100% Compressor Capacity Control

14, 16 HP Outdoor Unit

100% 210 Hz52 Hz + No. 2 + No.3 No. 1 Compressor Compressor 35 Steps Inverter Control No. 3 Compressor No. 1 100% Operation Compressor Inverter Control No. 2 No. 2 Compressor Compressor No. 1 100% Operation 100% Operation Compressor Inverter Control Large Load Small

Light weight, Compact Units
Indoor units are so lightweight and compact that they can be installed in any ceiling space. Outdoor units do not require special cranes or conveyors to move them. They can even be hauled in a building elevator.
Inverter Control 21052 Hz 20 steps

210 Hz52 Hz 20 Steps

210 Hz52 Hz No. 1 + No. 2 Compressor Inverter Control Compressor 29 Steps No. 2 Compressor 100% Operation

Inverter Control

No. 1 Compressor Inverter Control Small
8 HP 15% Large Load Small 10 HP 13% Large Load

Elevator

Installation by Floor
If necessary, installation can be performed by floor. The installers do not have to wait until the entire system is installed in the building to test the system in each section.
Automatic Cooling and Heating Switching
The difference between the set temperature and actual room temperature is detected and the cooling or heating mode is automatically switched over.

Auto Swing

Whether it be a ceiling-mounted cassette (double- flow/multiflow/600 x 600 multi-flow) type, ceiling-mounted cassette corner type, ceiling-suspended type or wall-mounted type, all these indoor units have an Auto Swing mechanism that helps keep the room temperature uniform.
Low Operating Sound Design
All indoor units have a low operating sound design.

LCD Remote Controller

The remote controller uses an easy-to-read liquid crystal display for easy operation. A full line of wired and wireless controllers is available for the indoor units of all types.

Auto Restart Function

Even if there is an extended power failure, the VRV system will automatically restart operation. A power failure will not cause any settings to be lost, thus eliminating the need for re-programming.
Individual Control Systems

Wired remote controller

(Optional)
Large liquid crystal screen displays complete operating status. Digital display lets you set temperature in 1C units. Lets you individually program by timer the respective times for operation start and stop within a maximum of 72 hours. Equipped with a thermostat sensor in the remote controller that makes possible more comfortable room temperature control. Monitors room temperature and preset temperature by microcomputer, and can select cool/heat operation mode automatically. (VRV System Heat Recovery series only) Enables you to select cool/heat/fan operation mode with the indoor remote controller of your choice without using the cool/heat selector. (VRV Inverter series, Heat Recovery series, PLUS series) Constantly monitors malfunctions in the system for 80 items, and is equipped with a "self-diagnosis function" that lets you know by message immediately when a malfunction occurs. Lets you carry out various field settings by remote controller.
Wireless remote controller (Optional)
The same operation modes and settings as with wired remote controllers are possible. A compact light receiving unit to be mounted into a wall or ceiling is included. A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow and 600 x 600 multi-flow) type, ceiling-suspended type and wall-mounted type is mounted into the indoor unit. Signal receiving unit can be installed on the panel

ex. 600 x 600 multi-flow type

Signal receiving unit

(Separate type)
Wireless remote controller

(Installed type)

Simple remote controller (Optional)
Control of Cool/Heat In all the series of VRV, Cool/Heat changeover in the same refrigerant circuit can be changed by the remote controller of the indoor unit. changeover Group control
Control by two remote controller
Equipment related to the central control
One remote controller can control the operation of max.16 indoor units at the same time.
The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last command has a priority.) Of course, the group control by two remote controller is also possible.
The remote controller has centralized its frequently used operation selectors and switches (on/off, operation mode, temperature setting and airflow volume), making itself suitable for use in hotel rooms or conference rooms.

Concealed type

(For hotel use)
Remote controller Remote controller Indoor unit

Remote control

The wiring of remote controller can be extended to max.500m and it is possible to install the remote controllers for the different indoor units in one place.
Exposed type The concealed-type remote controller smartly fits into a night table or console panel in a hotel room.

Remote controller

3 Control for the combined operation

Forced OFF input HRV

The operation of HRV can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.
Wide variation of remote controllers for indoor units
FXCQ FXFQ FXZQ FXKQ FXSQ FXMQ FXHQ FXAQ ( Q FXL N) Wired remote controller
Remote controller Remote controller
Expansion of system control
The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.

Set back time clock *

Set back time clock (Optional)
Connected to LCD wired remote controller (BRC type), this time clock can set 2 sets of on/off times in an increment of 30 minutes within a day. For each on/off setting a temperature setting is also possible.
(Installed signal receiving unit)
(Separate type signal receiving unit)

Simple remote controller

(Exposed type)
(Concealed type: for Hotel use)

Set back time clock

Centralized Control Systems
Up to 64 groups of indoor units (128 units) can be centrally controlled. Optional controllers for centralized control can be combined freely, and system can be designed in accordance with building scale and purpose. System integration with various air-conditioning peripheral equipment such as HRV (Heat Reclaim Ventilation) is easy. Wiring can be run up to a total length of 2 km, and adapts easily to large-scale system expansion.

Central remote controller (Optional)
64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.
Max.64 groups (128 indoor units controllable) Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. Zone control Malfunction code display Max. wiring length 1,000 m (Total : 2,000 m) Combination with Unified ON/OFF controller, schedule timer and BMS system
Unified on/off controller (DCS301B61) Connection of up to 8 units possible Address setting of central control can be performed from the remote controller.
Independent and centralized control of HRV is possible.

DCS302B61

Unified ON/OFF controller (Optional)
Group control of up to 16 units is possible (group control via automatic address setting)
16 groups of indoor units can be operated simultaneously/individually.
Max. 16 groups (128 indoor units) controllable 2 remote controllers can be used to control from 2 different places. Operating status indication (Normal operation, Alarm) Centralized control indication Max. wiring length 1,000 m (Total : 2,000 m) Compact size casing (Thickness : 16 mm) Combination with Central Remote controller, Schedule timer and BMS system
System without remote control is also available.

Forced shut-down input

Central control adaptor kit (DTA107A55).
Wiring adaptor for other airconditioners (DTA103A51)
Outdoor-air processing unit can be connected.

DCS301B61

Central remote controller (DCS302B61) Up to 2 units connectable
Interface adaptor for SkyAir series (built-in indoor unit) (DTA102A52)
Schedule timer (Optional)
Max.128 indoor units can be operated as programed schedule.

6 cores

7 cores max.
Interlink Building Management System (host computer monitor panel) also possible
Schedule timer (DST301B61) 1 unit connection possible ; 8 weekly schedule control patterns possible

Unification adaptor for computerized control * (DCS302A52)
Outdoor-air processing units cannot be controlled with indoor units in the same group, and cannot be connected to VRV-Plus Series.
Max. 128 indoor units controllable 8 types of weekly schedule Max. 48 hours back up power supply Max. wiring length 1,000 m (Total : 2,000 m) Compact size casing (Thickness : 16 mm) Combination with Central Remote controller, Unified ON/OFF controller and BMS system

DST301B61

Central remote controller No. of unit

(Max. 2 units)

Indoor unit Maximum 128 units Indoor unit for VRV Indoor unit of SkyAir
(separate adaptor is required)
Outdoor unit Maximum 10 units Outdoor unit for VRV(*3)
Associated with adaptor PC board Maximum 10 units Wiring adaptor for electrical appendices (Max. 1 unit) External control adaptor for outdoor unit Part name Model No. Function Interface between the central monitoring board and central control units. Combined with the central remote controller, this adaptor enables the central monitoring board to centralize such functions as the on/off control, operation status monitoring, and normal/malfunction monitoring.(*1) Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.
(*1) Central remote controller Unified ON/OFF controller

(Max. 8 units)

Details
Schedule timer (Max. 1 unit) Parallel interface (Max. 4 units)
HRV BS unit (*2) ( FD(Y)M-FA, FDYB-KA, FD Y)-K(A), FVY(P)J-A, UAT(Y)-K(A) series
Unification adaptor for computerized control

DCS302A52

Interface adaptor for SkyAir series Central control adaptor kit Wiring adaptor for other air-conditioner
Note : 1. Installation box for adaptor must be procured on site.

DTA102A52

( For SkyAir, FD(Y)M-FA, FDYB-KA, FDY-KA, FVYP)J-A
Wiring adaptor for other air-conditioner Outdoor-air processing unit
Note : (*1) When eight or more central remote controllers are used, the following conditions must be met. (These conditions do not apply for up to seven units.) - Central remote controllers + Indoor units + Outdoor units + Other adapters 160 units - Converted central remote controllers* + Indoor units + Outdoor units + Other adapters 200 units * Converted by assuming that one central controller unit (excluding the ON/OFF controller) represents 10 units. (*2) When using BS units, indoor units connected to the BS units are not included in the number of units. (*3) A maximum of 10 outdoor units and 5 function units can be connected.

Heat recovery operation

(cooling and heating operation)
cooling cooling heating heating
Heat absorption tendency heat recovery operation
REYQ28MY1B REYQ30MY1B REYQ32MY1B REYQ34MY1B REYQ36MY1B REYQ38MY1B REYQ40MY1B REYQ42MY1B REYQ44MY1B REYQ46MY1B REYQ48MY1B
(mainly heating, part cooling operation)
cooling heating heating heating

Heat absorption

Heat absorption operation

(all heating operation)

Series Line Up

Series

Heat pump type Heat recovery type

Capacity range

heating heating heating heating
5 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP 28 HP 30 HP 32 HP 34 HP 36 HP 38 HP 40 HP 42 HP 44 HP 46 HP 48 HP
Note: Operation modes (A) and (E) are applicable when the outdoor temperature is 35C and 0C respectively; The other modes are applicable under typical outdoor conditions.

Compressor power ratio

Heat radiation to outdoor air

Unit load

HP 5 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP 28 HP 30 HP 32 HP 34 HP 36 HP 38 HP 40 HP 42 HP 44 HP 46 HP 48 HP Model name RXYQ5M RXYQ8M RXYQ10M RXYQ12M RXYQ14M RXYQ16M RXYQ18M RXYQ20M RXYQ22M RXYQ24M RXYQ26M RXYQ28M RXYQ30M RXYQ32M RXYQ34M RXYQ36M RXYQ38M RXYQ40M RXYQ42M RXYQ44M RXYQ46M RXYQ48M Combination RXYQ5M RXYQ8M RXYQ10M RXYQ12M RXYQ14M RXYQ16M RXYQ8M + RXYQ10M RXYQ10M x 2 RXYQ10M + RXYQ12M RXYQ10M + RXYQ14M RXYQ10M + RXYQ16M RXYQ12M + RXYQ16M RXYQ14M + RXYQ16M RXYQ16M x 2 RXYQ10M x 2 + RXYQ14M RXYQ10M x 2 + RXYQ16M RXYQ10M + RXYQ12M + RXYQ16M RXYQ10M + RXYQ14M + RXYQ16M RXYQ10M + RXYQ16M x 2 RXYQ12M + RXYQ16M x 2 RXYQ14M + RXYQ16M x 2 RXYQ16M x 22 20
Number of connectable indoor units
Ceiling Mounted Cassette <Double flow> Type
Power supply Cooling capacity kcal/h (*1) Btu/h (*1) kW Heating capacity (*1) (*2) 2,000 7,900 2.3 2.2 2,200 8,500 2.5 2,500 9,900 2.9 2.8 2,800 10,900 3.2
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
1 phase, 220 - 240V/220V, 50/60Hz 3,150 12,500 3.7 3.6 3,400 13,600 4.0 4,000 15,900 4.7 4.5 4,300 17,000 5.0 5,000 19,900 5.8 5.6 5,400 21,500 6.3 6,300 25,000 7.3 7.1 6,900 27,300 8.0 8,000 31,800 9.3 9.0 8,600 34,100 10.0 12,500 49,600 14.5 14.0 13,800 54,600 16.0

kcal/h Btu/h kW

Casing Air flow rate (Hi/Lo) m3/min cfm Sound level (Hi/Lo) Dimensions (HXW XD) Machine weight dB(A) 220V 240V 7/5 247/177 32/27 34/29 305X775X600 26.0 6.4 12.7 9/6.5 318/230 34/28 36/30 305X775X600 26.0 6.4 12.7 9/6.5 318/230 34/28 36/30 305X775X600 26.0 6.4 12.7
Galvanized steel plate 12/9 424/318 34/29 37/32 305X990X600 31.0 6.4 12.7 12/9 424/318 34/29 37/32 16.5/13 582/459 37/32 39/34 26/21 918/741 39/34 41/36 33/25 1,165/883 44/38 46/40
305X990X600 305X1,175X600 305X1,665X600 305X1,665X600 32.0 6.4 12.7 35.0 9.5 15.9 47.0 9.5 15.9 48.0 9.5 15.9
Piping connections Liquid(Flare)mm Gas(Flare)mm Drain piping Panel(Option)

600X600 Multi Flow Ceiling Mounted Cassette Type
Power supply Cooling capacity kcal/h(*1) Btu/h(*1) kW Heating capacity (*1) (*2) kcal/h Btu/h kW Casing Air flow rate (Hi/Lo) m3/min 50Hz cfm Sound level (Hi/Lo)

(240V)

Ceiling Mounted Built-in Type
Power supply 5,000 19,900 5.8 5.6 5,400 21,500 6.3 Casing 11/8 388/282 38/29 14/10 494/353 45/35 Sound level (Hi/Lo) Dimensions(HXW XD) 6.4 12.7 6.4 12.7 Machine weight Air flow rate (Hi/Lo) m3/min cfm dB(A) 220V 240V 9/6.5 318/230 37/32 39/34 30.0 6.4 12.7 9/6.5 318/230 37/32 39/34 30.0 6.4 12.7 9.5/7 335/247 38/32 40/34 30.0 6.4 12.7 Heating capacity Cooling capacity kcal/h (*1) Btu/h (*1) kW (*1) (*2) Btu/h kW 2,000 7,900 2.3 2.2 2,200 8,500 2.5 2,500 9,900 2.9 2.8 2,800 10,900 3.2 3,150 12,500 3.7 3.6 3,400 13,600 4.0
FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ40MVE FXZQ50MVE
1 phase, 220-240V/220V, 50/60Hz 2,000 7,900 2.3 2.2 2,200 8,500 2.5 9/7 318/247 31/26 2,500 9,900 2.9 2.8 2,800 10,900 3.2 9/7 318/247 33/27 3,150 12,500 3.7 3.6 3,400 13,600 4.0 Galvanized steel plate 9.5/7.5 335/265 35/6.4 12.7 6.4 12.7 6.4 12.7 BYFQ60BW1 White 55X700X700 kg 2.7 55X700X700 2.7 55X700X700 2.7 55X700X700 2.7 55X700X700 2.7 50Hz 4,000 15,900 4.7 4.5 4,300 17,000 5.0
FXSQ20MVE FXSQ25MVE FXSQ32MVE FXSQ40MVE FXSQ50MVE FXSQ63MVEFXSQ80MVEFXSQ100MVE FXSQ125MVE
1 phase, 220 - 240V/220V, 50/60Hz 4,000 15,900 4.7 4.5 4,300 17,000 5.0 11.5/9 406/318 38/32 40/34 30.0 6.4 12.7 5,000 19,900 5.8 5.6 5,400 21,500 6.3 15/11 530/388 41/36 43/38 31.0 6.4 12.7 6,300 25,000 7.3 7.1 6,900 27,300 8.0 21/15.5 741/547 42/35 44/37 41.0 9.5 15.9 8,000 31,800 9.3 9.0 8,600 34,100 10.0 27/21.5 953/759 43/37 45/39 51.0 9.5 15.9 10,000 39,700 11.6 11.2 10,800 42,700 12.5 28/22 43/37 45/39 51.0 9.5 15.9 12,500 49,600 14.5 14.0 13,800 54,600 16.0 38/28 46/41 48/43 52.0 9.5 15.9

kcal/h

Galvanized steel plate 988/777 1,341/988
dB(A) mm kg Gas(Flare)mm Drain piping

Dimensions

(HXW XD)

260(286)X575X575

( ):include control box kg

Machine weight

300X550X800 300X550X800 300X550X800 300X700X800 300X700X800 300X1,000X800 300X1,400X800 300X1,400X800 300X1,400X800
Piping connections Liquid(Flare)mm
Piping connections Liquid(Flare)mm Gas(Flare)mm Drain piping Panel(Option) Dimensions (HXW XD) Model Colour mm weight kg
VP20 (External Dia, 26/Internal Dia, 20)
Panel (Option) Dimensions (HXW XD)

Model Colour mm weight

VP25 (External Dia, 32/Internal Dia, 25) BYBS32DJW1 BYBS32DJW1 BYBS32DJW1 BYBS45DJW1 BYBS45DJW1 BYBS71DJW1 BYBS125DJW1 BYBS125DJW1 BYBS125DJW1 White 55X650X500 55X650X500 55X650X500 55X800X500 55X800X500 55X1,100X500 55X1,500X500 55X1,500X500 55X1,500X500
3.0 3.0 3.0 3.5 3.5 4.5 6.5 6.5 6.5
Ceiling Mounted Cassette Corner Type
Power supply Cooling capacity kcal/h(*1) Btu/h(*1) kW Heating capacity (*1) (*2) Btu/h kW Casing Air flow rate (Hi/Lo) m3/min cfm Sound level (Hi/Lo) Dimensions (HXW XD) dB(A) 220V 240V kg Gas(Flare)mm Drain piping Panel (Option) Dimensions (HXW XD) Model Colour mm weight kg 70X1,240X800 8.5 70X1,240X800 8.5 BYK45FJW1 11/9 388/318 38/33 40/35 215X1,110X710 31.0 6.4 12.7 2,500 9,900 2.9 2.8 2,800 10,900 3.2
Ceiling Mounted Duct Type

FXKQ32MVE

3,150 12,500 3.7 3.6 3,400 13,600 4.0 11/9 388/318 38/33 40/35 215X1,110X710 31.0 6.4 12.7 BYK45FJW1 White 70X1,240X800 8.5 70X1,440X800 9.5
Note : Specifications are based on the following conditions; Cooling : (*1) Indoor temp. of 27 CDB, 19.5CWB, and outdoor temp. of 35.0 CDB. (*2) Indoor temp. of 27 CDB, 19.0CWB, and outdoor temp. of 35.0 CDB. Heating : Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length : 7.5m Level difference : 0m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for detail.) Sound level : (FXSQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit center. (FXMQ-M) Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

FXKQ25MVE

FXKQ40MVE
4,000 15,900 4.7 4.5 4,300 17,000 5.0 13/10 459/353 40/34 42/36 215X1,110X710 31.0 6.4 12.7 BYK45FJW1

FXKQ63MVE

6,300 25,000 7.3 7.1 6,900 27,300 8.0 18/15 635/530 42/37 44/39 215X1,310X710 34.0 9.5 15.9 BYK71FJW1
Power supply Cooling capacity kcal/h (*1) Btu/h (*1) (*1) kW Heating capacity (*2)
FXMQ40MVE FXMQ50MVE FXMQ63MVEFXMQ80MVEFXMQ100MVE FXMQ125MVE FXMQ200MVE FXMQ250MVE
1 phase, 220 - 240V/220V, 50/60Hz 4,000 15,900 4.7 4.5 4,300 17,000 5.0 5,000 19,900 5.8 5.6 5,400 21,500 6.3 6,300 25,000 7.3 7.1 6,900 27,300 8.0 8,000 31,800 9.3 9.0 8,600 34,100 10.0 10,000 39,700 11.6 11.2 10,800 42,700 12.5 12,500 49,600 14.5 14.0 13,800 54,600 16.0 20,000 79,000 23.0 22.4 21,500 85,300 25.0 25,000 99,000 28.8 28.0 27,000 107,500 31.5

1 phase, 220 - 240V/220V, 50/60Hz 2,000 7,900 2.3 2.2 2,200 8,500 2.5 2,500 9,900 2.9 2.8 2,800 10,900 3.2 3,150 12,500 3.7 3.6 3,400 13,600 4.0 4,000 15,900 4.7 4.5 4,300 17,000 5.0 5,000 19,900 5.8 5.6 5,400 21,500 6.3 6,300 25,000 7.3 7.1 6,900 27,300 8.0

m3/min cfm dB(A) mm kg

12/10 424/353 36/31 195X960X680 24.0 6.4 12.7
17.5/14 618/494 39/34 195X1,160X680 28.0 9.5 15.9 VP20 (External Dia, 26/Internal Dia, 20)
25/19.5 883/688 45/37 195X1,400X680 33.0 9.5 15.9
Casing Air flow rate (Hi/Lo) m3/min cfm Sound level (Hi/Lo) dB(A) 220V 240V Dimensions (HXW XD) mm 7/6 247/212 35/32 37/34
FXLQ:Ivory white / FXNQ:Galvanized steel plate 7/6 247/212 35/32 37/34 600X1,000X222 610X930X220 25.0 19.0 6.4 12.7 8/6 282/212 35/32 37/34 600X1,140X222 610X1,070X220 30.0 23.0 6.4 12.7 21O.D. 11/8.5 388/300 38/33 40/35 600X1,140X222 610X1,070X220 30.0 23.0 6.4 12.7 14/11 494/388 39/34 41/36 600X1,420X222 610X1,350X220 36.0 27.0 6.4 12.7 16/12 565/424 40/35 42/37 600X1,420X222 610X1,350X220 36.0 27.0 9.5 15.9
Dimensions(HXW XD) Machine weight
FXLQ 600X1,000X222 FXNQ 610X930X220 25.0 19.0 6.4 12.7

FXLQ FXNQ

Wall Mounted Type
Gas(Flare)mm Drain piping
FXAQ20MVE FXAQ25MVE FXAQ32MVE FXAQ40MVE FXAQ50MVE FXAQ63MVE
1 phase, 220-240V/220V, 50/60Hz 2,000 7,900 2.3 2.2 2,200 8,500 2.5 2,500 9,900 2.9 2.8 2,800 10,900 3.2 3,150 12,500 3.7 3.6 3,400 13,600 4.0 White m3/min cfm dB(A) mm kg 7.5/4.5 265/159 35/29 290X795X230 11.0 6.4 12.7 8/5 282/177 36/29 290X795X230 11.0 6.4 12.7 9/5.5 318/194 37/29 290X795X230 11.0 6.4 12.7 12/9 424/318 39/34 290X1,050X230 14.0 6.4 12.7 15/12 530/424 42/36 290X1,050X230 14.0 6.4 12.7 19/14 671/494 46/39 290X1,050X230 14.0 9.5 15.9 4,000 15,900 4.7 4.5 4,300 17,000 5.0 5,000 19,900 5.8 5.6 5,400 21,500 6.3 6,300 25,000 7.3 7.1 6,900 27,300 8.0
Note : Specifications are based on the following conditions ; CDB, 19.5CWB, and outdoor temp. of 35.0 CDB. Cooling : (*1) Indoor temp. of 27 (*2) Indoor temp. of 27 CDB, 19.0CWB, and outdoor temp. of 35.0 CDB. Heating : Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length : 7.5m Level difference : 0m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for detail.) Sound level : Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
VP13 (External Dia, 18/Internal Dia, 14)
Note : Specifications are based on the following conditions; Cooling : (*1) Indoor temp. of 27 CDB, 19.5CWB, and outdoor temp. of 35.0 CDB. (*2) Indoor temp. of 27 CDB, 19.0CWB, and outdoor temp. of 35.0 CDB. Heating : Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Equivalent piping length : 7.5m Level difference : 0m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See ENGINEERING DATA for detail.) Sound level : Anechoic chamber conversion value, measured under JISB8616 conditions. During actual operation, these values are normally somewhat higher as a result of ambient conditions.

Heating capacity (*3)

V1: 1 phase, 220-240V, 50Hz More than 100 but 160 or less 160 or more but less than 250 Galvanized steel plate 185X310X280 185X590X435 9.5 (Flare) 9.5 (Flare) 15.9 (Flare) 22.2 (Flange) 9.5 (Flare) 9.5 (Flare) 15.9 (Flare) 22.2 (Flange) 12.7 (Flare) 19.1 (Flare) 11.0 21.0
Capacity control Casing color Compressor
Motor output kW Air flow rate Dimensions(HXW XD) Sound level (380V) (*4) Refrigerant Refrigerant oil Refrigerant oil charge Piping connections m3/min mm dB(A)
Ceiling mounted cassette type (Double flow type)

Type FXCQ20M Item

1 Decoration Panel
Liquid mm Suction gas mm Discharge gas mm Oil mm

FXCQ25M FXCQ32M

FXCQ40M

FXCQ50M

FXCQ63M FXCQ80M FXCQ125M
BYBC63GJW1 BYBC63G-W1 KAFJ532G80 KAFJ533G80 KDDFJ53G80 KAFJ531G80 BYBC125GJW1 BYBC125G-W1 KAFJ532G160 KAFJ533G160 KDDFJ53G160 KAFJ531G160
REYQ34MY1B REYQ36MY1B REYQ38MY1B REYQ40MY1B REYQ42MY1B REYQ44MY1B REYQ46MY1B REYQ48MY1B MODEL Constituent Model REYQ10MY1B REYQ10MY1B REYQ10MY1B REYQ10MY1B REYQ10MY1B REYQ12MY1B REYQ14MY1B REYQ16MY1B REYQ10MY1B REYQ10MY1B REYQ12MY1B REYQ14MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ14MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B REYQ16MY1B
85,500 338,000 99.1 96.0 92,700 370,000 108.0 4-100 90,000 354,101 97,000 387,000 113.0 4-100 95,000 374,106 102,000 407,000 119.0 4-phase, 380 - 415V, 50Hz 101,000 105,000 397,000 413,113 113,000 109,000 433,000 450,132 4-100 4-100 Ivory white(5Y7.5/1) Hermetically sealed scroll type 110,000 432,123 118,000 470,4-100 116,000 455,129 125,000 496,3-100 120,000 471,134 129,000 513,3-100

Filter related

BYBC32GJW1 BYBC32G-WHigh efficiency filter 65% KAFJ532GHigh efficiency filter 90% KAFJ533G36 Filter chamber bottom suction KDDFJ53G36 Long life replacement filter KAFJ531G36
BYBC50GJW1 BYBC50G-W1 KAFJ532G56 KAFJ533G56 KDDFJ53G56 KAFJ531G56
1 BYBC-GJW1: Without origin, BYBC-G-W1: With origin 2 Filter chamber is required if installing high efficiency filter.
Ceiling mounted super cassette type (Multi flow type)
Type FXFQ25M FXFQ32M FXFQ40M FXFQ50M FXFQ63M FXFQ80MFXFQ100MFXFQ125M
BYCP125D-W1 KDBH55D160W KDBJ55K160W KAFP556D80 KAFP557D80 KAFJ552K80 KAFJ553K80 KDDFP55D160 KAFJ551C160 KAFP55D160 KAFJ55K160H KDDP55D160 KDDP55D160K KDDJ55X160 KDP55D80 KKSJ55K160 KDT-55D80
(2.7+4.5)X2+ (2.7+4.5)X2+ (2.7+4.5)+(4.2+4.5)+(2.7+4.5)+(2.0+4.5+4.5)+ (2.7+4.5)+ (4.2+4.5)+ (2.0+4.5+4.5)+ X X X X (3.0+4.5+4.5) 2 (3.0+4.5+4.5) 2 (3.0+4.5+4.5) 2 (3.0+4.5+4.5) 3 (2.0+4.5+4.5) (3.0+4.5+4.5) (3.0+4.5+4.5) (3.0+4.5+4.5) Air flow rate m3/min 180+180+210 180+180+210 180+210+210 180+210+210 180+210+210 210+210+210 210+210+210 210+210+210 Dimensions(HXW XD) (1,600X930X765)+(1,600X930X765)+ (1,600X930X765)+(1,600X1,240X765)+ (1,600X1,240X765)+(1,600X1,240X765)+ mm (1,600X1,240X765) (1,600X1,240X765) (1,600X1,240X765) dB(A) Sound level (380V) (*4) R410A Refrigerant Refrigerant oil Synthetic (ether) oil (1.9+1.6)+(1.9+1.6+1.6)+(1.9+1.6+1.6) (1.9+1.6+1.6)+(1.9+1.6+1.6)+(1.9+1.6+1.6) Refrigerant oil charge (1.9+1.6)+(1.9+1.6)+(1.9+1.6+1.6) Liquid mm 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) 19.1 (Brazing) Piping connections Suction gas mm 34.9 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) 41.3 (Brazing) Discharge gas mm 28.6 (Brazing) 28.6 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) 34.9 (Brazing) Oil mm 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) 6.4 (Flare) Motor output kW

Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.
Wiring adaptor for other air-conditioner D -NET
Up to 1024 units can be centrally controlled in 64 different groups. DTA109A51 Wiring restrictions (max. lengh : 1,000m, total wring lengh : 2,000m, max. number of branches : 16) apply to each adaptor. Fixing plate for DTA109A51
Expander Adaptor Mounting plate
adaptor must be procured on site.

KRP4A92

Note: Installation box for

Heat Reclaim Ventilation

Models
Power Supply Temp. Exchange Efficiency (%) [50Hz/60Hz] Ultra-High High Low Ultra-High Enthalpy Exchange Efficiency (%) [50Hz/60Hz] For Heating High Low Ultra-High For Cooling High Low 74/74 74/74 79/80 64/64 64/64 69/71 58/58 58/58 64/66 72/72 72/72 77/77 64/64 64/64 68/69 58/58 58/58 62/63 28-29/29.5 26-27/26 21-22/19.5 28-29/29 27-28/27 21-22/20.5 75/75 75/75 80/81 65/65 65/65 70/71 61/61 61/61 67/68 32-34/34.5 31.5-33/32 23.5-26/22 32-34/34.5 31-32.5/33
VAM150FAVE VAM250FAVE VAM350FAVE VAM500FAVE VAM650FAVE VAM800FAVE VAM1000FAVEVAM1500FAVE VAM2000FAVE
VE: 1 phase, 220-240V/220V, 50Hz/60Hz 74/74 74/74 77/78.5 62/62 62/62 67/68.5 58/58 58/58 63/65.5 33-34.5/34 31.5-33/31 24.5-26.5/24 74/74 74/74 77/78 63/63 63/63 66/68 58/58 58/58 63/65 34.5-35.5/36 33-34/33 27-28/27 74/74 74/74 76/76 65/65 65/65 67/68 60/60 60/60 62/63 36-37/37 34.5-36/35 31-32/30 36-37/37 34.5-36/35 31-33/31 75/75 75/75 76.5/78 66/66 66/66 68/71 61/61 61/61 63/66 36-37/37 35-36/35 31-32/30 36-37/37 35.5-36/35 31-32/31 75/75 75/75 78/78 66/66 66/66 68/68 61/61 61/61 64/64 39.5-41.5/40.5 38-39/38 34-36/33 40.5-41.5/40.5 38-39/38 33.5-36/33 75/75 75/75 78/78 66/66 66/66 70/70 61/61 61/61 66/66 40-42.5/41 38-41/38 35-37/35 40-42.5/41 38-41/38 35-37/35
Daikin's HRV (Heat Reclaim Ventilation) recovers heat energy lost through ventilation and holds down room temperature changes caused by ventilation, thereby maintaining a comfortable and clean environment. This also curbs the load on the air conditioning system and conserves energy. In addition, the HRV is interlocked to Daikin's VRV system, SkyAir and other air conditioning systems an d automatically switches over ventilation mode, further increasing the effects of energy conservation. HRV operation has been centralized on the air conditioner remote controller allowing total control over air conditioning and ventilation with a simple configuration.

Daikin air conditioner

ON/OFF signal Cooling/Heating mode signal Set temperature signal Ventilation signal Humidifier ON/OFF signal
Sound Level dB(A) [50Hz/60Hz]

-10 -20

Note: 1. Sound level is measured at 1.5m below the center of the body. 2. Air flow rate can be changed over to Low mode or High mode. 3. Sound level is measured in an anechoic chamber. Sound level generally become greater than this value depending on the operating conditions, reflected sound, and peripheral noise. 4. The sound level at the air discharge port is about 8 dB higher than the unit's sound level. 5. Even when the outdoor temperature is below -15C, the system is operable down to -20C with the preheater installed at the outdoor air intake side.

285 mm

-15CDB

Precautions

System/ Precautions on
Refrigerant Refrigeration oil Condensing pressure R22 Mineral oil (Suniso) 1.84MPa (18.8kg/cm 2) R410A Synthetic (ether) oil 2.97MPa (30.3kgf/cm 2)
(Single-component refrigerant) (Quasi-azeotropic mixture refrigerant)

Installation

Several dedicated tools are required for the installation work of R410A models. Some of conventional tools can be used except tools actually used to the installation work for R22 models.
R410A applies higher pressure than R22 and uses refrigeration oil different from R22. Therefore, piping works and tools are also different from those for R22 refrigerants.
Refrigerant Piping Materials

REFNET piping materials

Branch pipe and dividing pipe for R410A are provided specially for REFNET piping. Since these new parts are not interchangeable with current REFNET parts, do not use current REFNET piping materials for R410A. (Refer to the option list)

Tool name Pipe cutter

Work process / Usage Pipe cutting Pipe flaring Applying to flared section Flare nut jointing Pipe expanding in connection of pipe Pipe bending Air tight test Oxidation proof for inside pipe Pipe brazing
Interchangeability with conventional tool Interchangeable and can be used. Dedicated flaring tool is required due to flaring dimension change. Use dedicated ether oil, ester oil, alkyl-benzene oil or mixture of these oils. Dedicated torque wrench is required due to different size of 1/2 "and 5/8" flare nuts.
Other refrigerant piping materials
Use C1220 type copper tube for refrigerant piping. Wall thickness of copper tube shown in the below table can be applied. (The table is same as the recommendation for R22)
Flaring tool Piping assembling oil Refrigerant (Refrigerant oil) piping work Torque wrench Pipe expander Pipe bender Nitrogen Welder Gauge manifold Charging hose

(Unit : mm)

Recommendable oil for pipe processing
DAPHNE MASTER DRAW 510LS 530LS565NR566LS (Idemitsu Kosan Co.,Ltd.) MASTER DRAW 5128 (ETNA PRODUCTS INC.) Shell Drawing XA (SHELL)

 

Tags

Yamaha GW10 Quikstart Akai S20 Travelmate 380 GR-AXM300u-gr-axm300 65 M Reader LX 300 GT1200 Radio Writer ZWF1621 Syncmaster 172S F5D8635-4 LX8000SA-22S GT1000D GE-60 HT-Z410t-XAA Nokia 6235 DES-1009G WM-14225FD 14PT1356-01 XA-250 Hdcsd9 F1022ND LN52A650a1F CD1352S-05 CHT-8R FX 203C URC 1001 ZHC900X KX-T3155 SGH-A411 FS-C5015N Printer MZ-60 S-350 RF-B33 Headphone Kxtga641EX DCS500 UT-110 M55-S331 Monitor EP-97 MG206C-mg166cx-mg166C KX-TD208E B3605 MS-570MS UPV5500 WM2688HCM DTB-P850Z BBA 2867 018 CR Review DV7732NSC JS-23 Pl9127C UE-46C7705 Esga21 Micro BR CDX-GT81UW Feedback DCR-TRV730E Radio Printer DSC-S750 Data PC VTX-D800U UX-V10 CRF 800 Webobjects 5 42LG60 Rancher Scubapro-uwatec OXY2 AOB60530X N91-2 HW Mp3 REX T65 3034D SA-HT1500 KDC-3080RG VSX-806RDS V-pass FX Plus M GR-D225 Observatory WAK3300 DCM-280 HP4500 Poulan 2350 Autoloader Kodak C530 STI64BF1 HL100E TL-WR941ND G2736N Pilots LX210-2003 CD255 Documate 252

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101