Reviews & Opinions
Independent and trusted. Read before buy Daikin Ekhbh007A!

Daikin Ekhbh007A

 

 

About Daikin Ekhbh007A
Here you can find all about Daikin Ekhbh007A like manual and other informations. For example: review.

Daikin Ekhbh007A manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Daikin Ekhbh007A please write about it to help other people.
[ Report abuse or wrong photo | Share your Daikin Ekhbh007A photo ]

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Daikin Ekhbh007A, size: 1.1 MB

Daikin Ekhbh007A

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

EEDE06-9

technical data

Altherma

ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300
Altherma ERYQ005-007A EKHBH007A / EKHBX007A EKSWW150-300
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
Zandvoordestraat 300 B - 8400 Ostend Belgium www.daikineurope.com

EEDE- 9

EEDE06-9 - 07/2006 Printed in Belgium by Goekint Graphics

Chillers R-410A ALTHERMA

erA el0 hl1 t4i l-h RAC

Cooling only

Heating only

Heat pump

4 Altherma Chillers
Outdoor units R-410A ERYQ

TABLE OF CONTENTS ERYQ

Features. 6 Specifications. 7
Nominal Capacity and Nominal Input

. 9... 7

Technical Specifications. Electrical Specifications.

Capacity tables.

Cooling/Heating capacity tables
Dimensional drawing & centre of gravity. 11
Dimensional drawing. Centre of gravity.
Piping diagram. 13 Wiring diagram. 14
Wiring diagram. External connection diagram.

Sound data. 16

Sound pressure spectrum.

Operation range.

Altherma Outdoor units
i n u a r m o rA o e0 dh1Q t4Y ulR- EAO R

Features

Cost effective alternative to a fossil fuel boiler Low energy bills and low CO2 emissions Easy to install Total solution for year round comfort

Specifications

EKHBH* ERYQ005A ERYQ006A ERYQ007A ERYQ005A EKHBX* ERYQ006A ERYQ007A
2-1 NOMINAL CAPACITY AND NOMINAL INPUT
Indoor Units Condition 1 Heating capacity Cooling capacity Heating PI Cooling PI COP EER Condition 2 Heating Minimum Nominal Minimum Nominal Nominal Nominal Nominal Nominal Minimum Nominal Cooling Minimum Nominal Heating PI Cooling PI COP EER Notes Nominal Nominal Nominal Nominal kW kW kW kW kW kW kW kW kW kW kW kW -
EKHBH007A* 4.36 5.75 7.45 1.26 4.56 3.87 5.03 6.68 1.58 3.18 -
EKHBH007A* 4.36 6.84 8.79 1.58 4.34 3.87 6.10 7.98 1.95 3.13 -
EKHBH007A* 4.36 8.43 9.58 2.08 4.05 3.87 7.64 8.76 2.54 3.00 -
EKHBX007A* 4.36 5.75 7.45 3.67 5.12 5.12 1.26 2.16 4.56 2.37 3.87 5.03 6.68 4.82 7.20 7.20 1.58 2.16 3.18 3.33
EKHBX007A* 4.36 6.84 8.79 3.67 5.86 6.13 1.58 2.59 4.34 2.26 3.87 6.10 7.98 4.82 8.16 8.50 1.95 2.59 3.13 3.15
EKHBX007A* 4.36 8.43 9.58 3.67 6.08 7.10 2.08 2.75 4.05 2.21 3.87 7.64 8.76 4.82 8.37 8.91 2.54 2.75 3.00 3.04

Maximum kW

*Condition 1 - cooling Ta 35C - LWE 7C - heating Ta DB/WB 7C/6C - LWC 35C (DT = 5C) * Condition 2 - cooling Ta 35C - LWE 18C (DT = 5C) - heating Ta DB/WB 7C/6C - LWC 45C (DT = 5C)
ERYQ005A (+ EKHBH) ERYQ006A (+ EKHBH) ERYQ007A (+ EKHBH) ERYQ005A (+ EKHBX) ERYQ006A (+ EKHBX) ERYQ007A (+ EKHBX)

Casing

TECHNICAL SPECIFICATIONS
Colour Material Unit Height Width Depth Packing Height Width Depth mm mm mm mm mm mm kg kg
Ivory white Polyester painted galvanised steel EPS Carton kg Length Nr of Rows Fin Pitch mm Nr of Stages mm 2 1.Hi-Xa(8) Type Treatment WF fin Anti-corrosion treatment (PE) Propeller 1 Quantity Output W 1 Model Type Motor Output W 2YC63BXD#C Hermetically sealed swing compressor 1920

Dimensions

Weight Packing
Unit Packed Unit Material Weight

Heat Exchanger

Tube type Fin Fan Type Quantity Motor Compressor Quantity Motor
Heating Cooling Sanitary water Min Max Min Max Min Max Sound Power Sound Pressure Cooling Sound Power Sound Pressure CWB CWB CDB CDB CDB CDB dBA dBA dBA dBA R-410A kg 1.7 Expansion valve(electronic type) 1 FVC50K l Type Diameter (OD) Gas Type Diameter (OD) Drain Quantity Type Diameter (OD) Piping Length Minimum mm m kg/m mm mm 0.75 Flare connection 6,35 Flare connection 15,Socket 30 0.02 IF > 10m 52 -66 53

Operation Range

Sound Level (nominal)

Heating

Refrigerant
Type Charge Control Nr of Circuits
Refrigerant Oil Piping connections
Type Charged Volume Liquid (OD)
Maximum m Additional Refrigerant Charge Installation height difference

Maximum m

Max. internunit level difference Defrost Method Defrost Control Capacity Control Method Standard Accessories Item Quantity Item Quantity
20 Reverse cycle Sensor for outdoor heat exchanger temperature Inverter controlled Installation manual 1 Drain plug 1
ELECTRICAL SPECIFICATIONS
Name Phase Frequency Voltage Voltage range Hz V Maximum V Cooling Heating Cooling Heating A A A A A Included earth wiring 11 16.25

Power Supply

V50 220-440 +10% 11

Current

Starting Current Maximum running Current
Recomended fuses Wiring connections For Power Supply Quantity
For connection Quantity with indoor Remark

COOLING

Capacity tables
Tamb (C) LWE (C) 20 LWC Tamb -15 -10 -7 -7 -15 -10 -7 -7 -15 -10 -7 -7 LWC Tamb -15 -10 -7 -7 -15 -10 -7 -7 -15 -10 -7 -CC 6.01 6.81 7.23 7.88 8.80 7.15 8.09 8.57 9.33 10.4 8.24 9.26 9.79 10.6 11.HC 3.93 4.65 5.14 6.06 6.89 8.03 4.87 5.67 6.21 7.23 8.14 9.40 5.42 6.27 6.84 7.92 8.9 10.HC 3.50 4.14 4.52 5.27 5.92 8.03 4.34 5.04 5.46 6.29 7.00 9.40 4.82 5.58 6.02 6.89 7.6 10.2 PI 1.40 1.45 1.45 1.46 1.45 1.57 1.73 1.79 1.80 1.81 1.81 1.98 1.96 2.03 2.04 2.07 2.08 2.28 HC 3.27 3.85 4.20 4.89 5.49 7.45 4.11 4.75 5.13 5.89 6.55 8.79 4.59 5.28 5.69 6.48 7.18 9.58 PI 1.48 1.52 1.54 1.57 1.57 1.57 1.82 1.88 1.91 1.95 1.97 1.98 2.06 2.13 2.17 2.22 2.26 2.28 HC 3.67 4.32 4.77 5.62 6.38 7.45 4.62 5.34 5.83 6.77 7.61 8.79 5.16 5.93 6.46 7.45 8.35 9.PI 1.51 1.56 1.58 1.60 1.60 1.75 1.85 1.92 1.94 1.98 1.99 2.19 2.08 2.17 2.20 2.25 2.27 2.51 HC 3.09 3.62 3.95 4.59 5.16 7.00 3.94 4.53 4.88 5.59 6.20 8.32 4.43 5.06 5.43 6.17 6.82 9.10 PI 1.56 1.57 1.57 1.56 1.55 2.05 2.09 2.11 2.13 2.16 2.43 2.49 2.52 2.57 2.63 CC 5.73 6.50 6.90 7.54 8.42 6.84 7.73 8.20 8.92 9.9 7.90 8.87 9.38 10.17 11.PI 1.59 1.65 1.68 1.72 1.74 1.75 1.94 2.02 2.07 2.13 2.16 2.19 2.19 2.29 2.34 2.41 2.46 2.51 HC 3.47 4.07 4.49 5.28 6.00 7.00 4.43 5.09 5.55 6.42 7.21 8.32 4.97 5.68 6.17 7.10 7.93 9.PI 1.62 1.70 1.72 1.75 1.76 1.94 1.98 2.07 2.10 2.15 2.18 2.42 2.23 2.34 2.37 2.44 2.47 2.76 HC 2.97 3.46 3.77 4.38 4.92 6.68 3.83 4.38 4.71 5.37 5.96 7.98 4.32 4.91 5.26 5.96 6.58 8.PI 1.75 1.77 1.78 1.78 1.79 2.28 2.34 2.36 2.40 2.44 2.68 2.76 2.80 2.86 2.94 CC 5.43 6.17 6.56 7.17 8.03 6.50 7.34 7.79 8.49 9.48 7.52 8.45 8.93 9.69 10.PI 1.71 1.79 1.83 1.88 1.91 1.94 2.08 2.18 2.24 2.32 2.37 2.42 2.34 2.46 2.53 2.62 2.69 2.76 HC 3.33 3.89 4.28 5.03 5.72 6.68 4.30 4.92 5.35 6.17 6.92 7.98 4.86 5.51 5.97 6.85 7.65 8.PI 1.75 1.84 1.87 1.92 1.94 2.15 2.12 2.24 2.28 2.35 2.38 2.66 2.39 2.52 2.57 2.65 2.70 3.02 HC 2.89 3.36 3.65 4.24 4.76 6.47 3.77 4.29 4.60 5.23 5.80 7.78 4.27 4.82 5.15 5.83 6.43 8.PI 1.95 1.98 2.00 2.01 2.03 2.52 2.59 2.63 2.68 2.73 2.94 3.05 3.10 3.17 3.26 CC 5.12 5.83 6.20 6.79 7.63 6.13 6.94 7.36 8.03 8.99 7.10 7.79 8.14 8.68 9.PI 1.84 1.94 1.99 2.06 2.11 2.15 2.23 2.36 2.42 2.52 2.59 2.66 2.51 2.65 2.73 2.85 2.93 3.02 HC 3.25 3.78 4.15 4.87 5.53 6.47 4.24 4.82 5.23 6.02 6.74 7.78 4.80 5.42 5.86 6.70 7.47 8.PI 1.89 2.00 2.03 2.10 2.13 2.37 2.28 2.42 2.47 2.56 2.61 2.92 2.56 2.72 2.78 2.88 2.94 3.PI 2.16 2.21 2.23 2.26 2.29 2.77 2.87 2.91 2.97 3.04 3.23 3.31 3.36 3.41 3.48 CC 4.80 5.30 5.56 5.95 6.48 5.35 5.84 6.09 6.46 6.96 5.68 6.12 6.34 6.67 7.PI 1.99 2.10 2.16 2.25 2.31 2.37 2.40 2.55 2.63 2.75 2.83 2.92 2.70 2.86 2.95 3.10 3.20 3.31

* The integrated heating capacity and power input, is the average heating capacity and power input during 1 cycle. (from end of defrost till end of the next defrost).
40 PI 2.39 2.32 2.28 2.22 2.13 2.68 2.62 2.59 2.53 2.44 2.86 2.80 2.77 2.71 2.61 CC 4.59 4.98 5.18 5.46 5.82 4.89 5.21 5.36 5.57 5.82 4.87 5.18 5.33 5.55 5.80
43 PI 2.53 2.38 2.30 2.18 1.99 2.59 2.43 2.34 2.20 1.99 2.59 2.43 2.35 2.20 1.99

HEATING (Peak values)

HEATING (integrated values*)

4TW56712-1A

SYMBOLS
CC HC PI LWE LWC Tamb : Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Power input (kW) : Leaving Water Evaporator temperature (C) : Leaving Water Condensor temperature (C) : Ambient temperature (C) RH=85% 1
Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38C Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 38C Power input Power input is total input according to Eurovent rating standard 6/C/003-2006
Dimensional drawing & centre of gravity

Dimensional drawing

unit (mm)
Drain outlet (I.D. J 15.9 hose for connection)
Minimum space for air passage
Wall height on air outlet side = less than 1200
In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10) Name plate Brand name label Wiring inlet Terminal strip with earth terminal Outdoor air thermistor
Liquid stop valve (J6.4 CuT) Service port Gas stop valve (J15.9 CuT)

3D051658B

Centre of gravity
The position of foundation bolt

4D042258G

Piping diagram

Outdoor unit

Heat exchanger
Outdoor temperature thermistor
Capillary tube 1 Muffler with filter Refrigerant flow Cooling Heating Capillary tube 4

Heat exchanger thermistor
Capillary tube 2 Capillary tube 3
Filter Motor operated valve Filter

Propeller fan

Four way valve on : heating

Muffler with filter

Muffler Liquid stop valve Muffler

Field piping

Field piping Discharge pipe thermistor Accumulator Gas stop valve with service port

Compressor

3D052750A

Wiring diagram

Power supply

To indoor unit

Sheet metal

Indoor

Field wiring (discharge) (outdoor) (Condenser)
Outdoor Z1CZ7C X1M, X2M Y1E V2, V3, V5, V9, V100 SA2 FU1, FU2, FU3: AC1, AC2 U, V, W, X11A, X12A E1, E2 HR1, HR2 : Ferrite core : Terminal strip : Electronic expansion valve coil : Varistor : Surge arrester : Fuse MRM10, MRM20 MRC/W R1TR3T S2S102 LEDA L N SW1 SW4 M1C M1F L1R : Magnetic relay : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch SW (SW1) : Local setting SW (SW4) : Compressor motor : Fan motor : Reactor Q1L PM1 PCB1,2 Y1R Sheet metal : Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate

: Connector

3D052296B

EKHB-A

External connection diagram
Standard parts Power supply Outdoor unit
Unit power supply: 230V + earth Backup heater power supply (3/6/9kW): 400V or 230V + earth 3 core X1M:L-N-Earth
For more details please check unit wiring diagram
Optional power supply Booster heater power supply (3kW): 400V or 230V + earth

X2M:1-2-3-Earth

4 core

3 or 4 core

3 core

Optional parts

Field supply

X1M:9-10-11-Earth

Sanitary tank Room thermostat
Power supply booster heater 4 core 5 core X1M:7-8-Earth A3P (optional)
Q2L - Clixon booster heater

230V or 400V

NO valve: NC valve:

2 core

2 way valve
M2S (EKHBX Units) for cooling mode
R5T - Thermistor water temperature
2 core Signal Thermistor cable Note: min. distance to power cable = 3cm

3 way valve

M3S (when EKSWW is installed) selection sanitary-floorheating

Indoor unit

User interface

3TW56719-6

Sound data

Sound pressure spectrum

ERYQ006ABV3 Cooling
Sound pressure level (dB)
Octave band center frequency (Hz)

ERYQ005ABV3 Cooling

3TW56717-1 NOTES
Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20Pa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

Coil Microphone

Location of microphone

ERYQ007ABV3 Cooling

Sound pressure level (dB) Sound pressure level (dB)

ERYQ005ABV3 Heating

3TW56717-2 NOTES

ERYQ007ABV3 Heating

ERYQ006ABV3 Heating

Operation range

Cooling mode

Outdoor temp. (CDB)

Leaving evaporator water temperature (C)

Heating mode

Leaving condenser water temperature (C)

Sanitary mode

: Booster heater operation only

4TW56713-1A

Indoor units R-410A EKHBH / EKHBX
TABLE OF CONTENTS EKHBH / EKHBX
Features. 20 Specifications.

Options.

Dimensional drawing & centre of gravity. 25
Piping diagram. 26 Wiring diagram. 27
Hydraulic performance. 30
Static pressure drop unit

Altherma Indoor units

H t K i E n u a/ m r rA Ho e0 Bo h1 Hd t4 nKl- EI AR
EKHBH007A (+ERYQ005A) EKHBH007A (+ERYQ006A) EKHBH007A (+ERYQ007A) EKHBX007A (+ERYQ005A) EKHBX007A (+ERYQ006A) EKHBX007A (+ERYQ007A)
Outdoor units Nominal input (Indoor only) Casing Dimensions Colour Material Packing Height Width Depth Unit Height Width Depth Weight Packing Unit Packed Unit Material mm mm mm mm mm mm kg kg

ERYQ005A

ERYQ006A

ERYQ007A 230

ERYQ007A
RAL9010 Polyester painted galvanised steel EPS Wood Carton PS(straps) 75
Weight Main components Pump Main components Pump Nominal ESP unit Pump Water side Heat exchanger Type
kg Nr. of speed Cooling Heating Power input Type Qty Water volume Water flow rate Min. l l/min kPa kPa W 46.5 40.1 29.0
10 Water cooled 3 49.9 46.Brazed plate 1 0.46.5 40.1 44.4 29.0
Water side Heat exchanger Main components
Water flow rate Nom. Water side Heat exchanger Expansion vessel

Cooling Heating

l/min l/min 16.5 19.6 24.2

14.7 16.5

16.5 19.6

17.6 24.2

Insulation material

Polyurethane foam

Volume Max. water pressure Pre pressure

bar mm

Water filter
Diameter perforations Material
Brass inch inch bar 1"MBSP 1"MBSP 3 Yes Yes Yes Yes

Water circuit

Piping connections diameter Piping Safety valve Manometer Drain valve / Fill valve Shut off valve Air purge valve
Gas side diameter Liquid side diameter Sound Pressure Waterside Cooling Heating mm mm dBA C C

Refrigerant Circuit

15,9 (2) 55 The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment. ERYQ = 6.35 mm EKHB = 9.52 mm (flare connection)

Sound Level Operation range Notes

Electric heater

Type Power Supply Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Phase Frequency Voltage Current Running Current Hz V A Hz V A Hz V A Hz V A Hz V A Hz V A
3V13 6V26 6W1 3N 8.6 6T15 9W1 3N 13 9T23

Type Power Supply

Optional equipment for EKHB(H/X)007*
Reference EKHBH007A3V3 EKHBX007A3V3 EKHBH007A6V3 EKHBX007A6V3 EKHBH007A6W1 EKHBX007A6W1 EKHBH007A6T1 EKHBX007A6T1 EKHBH007A9W1 EKHBX007A9W1 EKHBH007A9T1 EKHBX007A9T1

Description

Number

Availability

Heating only model Reversible model
Available options V V V V V V Factory mounted Factory mounted Factory mounted Factory mounted Factory mounted Factory mounted

Options

Back up heater 3kW 1230 V
Back up heater 6kW 1230 V
Back up heater 6kW 3400 V + N
Back up heater 6kW 3230 V
Back up heater 9kW 3400 V + N
Back up heater 9kW 3230 V
Available kits V V V V V V V V V V V V V V V V V V V V V V Kit Kit Kit Kit Kit

EKSWW150V3

Sanitary warm water tank 150 l 230 V

EKSWW200V3

Sanitary warm water tank 200 l 230 V

EKSWW300V3

Sanitary warm water tank 300 l 230 V

EKSWW200Z2

Sanitary warm water tank 200 l 400 V

EKSWW300Z2

Sanitary warm water tank 300 l 400 V

EKWBSWW150

Wall bracket for EKSWW150V3

3TW56719-5

EKHBH-A
Service door (Closed) 361 (Open) 553
Minimum space for service & ventilation

Min. 200

Center of gravity j Pump + switch for speed setting 1 j Remocon 2 j Water IN conection 1 M BSP 3 j Water OUT connection 1 M BSP 4 j Power supply intake (+ sanitary warm water tank) 5 j Drain / fill valve 6 j Air purge 7 j Expansion vessel + nipple 8 j Blow off valve 9 j Pressure gauge 10 j Water filter 11 j Suction pipe connection J15.9 flare connection 12 j Liquid pipe connection J9.52 flare connection 13 j Shut off valves (delivered with unit) 14 j Thermistor connection (+ sanitary warm water tank) 15 j Holes for fixation 16 j Blow off drain 17 j Switchbox connection terminals 18 j Wallbracket 19

1 female BSP

1 male BSP

Setup 1 Setup 2

A 200 350

B 400 200

Min. 400

Min. 100

3TW56714-1A

EKHBX-A

Service door

Min. 125

Center of gravity j Pump + switch for speed setting 1 j Remocon 2 j Water IN conection 1 M BSP 3 j Water OUT connection 1 M BSP 4 j Power supply intake (+ sanitary warm water tank) 5 j Drain / fill valve 6 j Air purge 7 j Expansion vessel + nipple 8 j Blow off valve 9 j Pressure gauge 10 j Water filter 11 j Suction pipe connection J15.9 flare connection 12 j Liquid pipe connection J9.52 flare connection 13 j Shut off valves (delivered with unit) 14 j Thermistor connection (+ sanitary warm water tank) 15 j Holes for fixation 16 j Blow off drain / drain of drainpan 17 j Switchbox connection terminals 18 j Wallbracket 19

(Closed) 461 (Open) 653

Dimensions wallbracket

3TW56724-1A

Water side

R4T R3T R2T R1T

Inlet water thermistor Refrigerant liquid side thermistor Outlet water backup heater thermistor Outlet water heat-exchanger thermistor

Field installation

Filter Inlet Shut off valve

Refrigerant side

Pressure gauge Drain valve

Safety valve

Expansion vessel Cooling (EKHBX) Heating (EKHBX + EKHBH) Drain valve Air purge Pump Option backup heater

Flowswitch Outlet

Overview
Electric heater body Refr. out
Shut off valve Evaporator Condensor Water inlet

Refr. in Refr. in

Water side Water outlet

Refr. out

O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipe

3TW56715-1

Power supply >> See note 2 << Only for EKSWW option Outdoor unit Sanitary tank

EKHBH/X-A3V3

Only for EKHB*00*A3V3 or6V3
Only for EKSWW option User interface V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K3M K2M K1M F2B F1B A3P A2P A1P : Spark suppression 2 : Spark suppression 1 : Fuse 3.15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat (field supply, PC = interval power circuit) : Remocon PCB : Main PCB

Only for EKHB*00*A6V3 NO valve Only for EKSWW option

supply from PCB

Only for EKHB*00*A3V3

model F1B model F2B

Electric heater option fuse 3V3 20A EKSWW kit fuse 20A
Sanitary tank Only for EKSWW option Only for EKHB*00*A3V3
Thermostat On/Off NC valve

heating cooling

Wiring dependent on model

Option

Field wiring

Wire colour

Notes: 1 This wiring diagram only applies to the indoor unit. 2 Use one and same dedicated power supply for indoor unit, outdoor unit and EKSWW option 3 :Field wiring 4 :Terminal strip :Connector :Terminal :Protective earth 5 Do not operate the unit by short-circuiting protection devices Q1L, Q2L, S1L. 6 BLK: Black / WHT: White / RED: Red / BLU: Blue / PINK: Pink / YLW: Yellow BRN: Brown / GRY: Grey / GRN: Green / ORG: Orange / VIO: Violet

3TW56716-4A

EKHBH/X-A6V3
Only for EKSWW option User interface X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3.15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat (field supply, PC = interval power circuit) : Remocon PCB : Main PCB
Only for EKSWW option NO valve

230V AC supply from PCB

Electric heater option fuse 6V3 32A EKSWW kit fuse 20A
Sanitary tank Only for EKSWW option

3TW56716-5

Power supply >> See note 2 << Outdoor unit Sanitary tank

EKHBH/X-A6W1/9W1

Only for EKSWW option
Only for EKSWW option X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3.15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat(Field supply) : Remocon PCB : Main PCB

User interface NO valve

Electric heater option fuse 6W1 9W1 13A 16A EKSWW kit fuse 20A
Thermostat On/Off Sanitary tank Only for EKSWW*V3 Option Sanitary tank Only for EKSWW*Z2 Option NC valve

3TW56716-2B

EKHBH/X-A6T1/9T1
Only for EKSWW option User interface X1M V2S V1S FU1 R1T (A2P) Q1DI Q2L Q1L TR1 R5T R4T R3T R2T R1T (A1P) S1L E4H E3H E2H E1H M3S M2S M1P K4M K3M K2M K1M F2B F1B A3P A2P A1P : Terminal block : Spark suppression 2 : Spark suppression 1 : Fuse 3.15A T 250V : Thermistor (air) : Earth leakage protector : Thermal protector booster heater : Thermal protector backup heater : Transformer 24V for PCB : SWW Thermistor : Inlet water thermistor : Refrigerant liquid side thermistor : Outlet water backup heater thermistor : Outlet water heat-exchanger thermistor : Flowswitch : Booster heater : Backup heater element 3 : Backup heater element 2 : Backup heater element 1 : 3 way valve floorheating / sanitary warm water : 2 way valve for cooling mode : Pump : Contactor backup heater : Contactor booster heater : Contactor backup heater Step 2 : Contactor backup heater Step 1 : Fuse booster heater : Fuse backup heater : Thermostat(Field supply) : Remocon PCB : Main PCB

NO valve

Electric heater option fuse 6T1 9T1 20A 32A EKSWW kit fuse 20A
Sanitary tank Only for EKSWW option Wiring dependent on model Field wiring Option

3TW56716-3B

Hydraulic performance

ESP = f (Flow)

ESP [mH2O]

Flow (l/min)

I: low speed setting pump II: medium speed setting pump III: high speed setting pump ESP: External static pressure Flow: waterflow trough the unit
Warning: Selecting a flow outside the curves can cause damage to or malfunction of the unit. See also minimum and maximum allowed water flowrate in the technical specifications.

4TW56749-2

Sanitary Hot Water R-410A EKSWW

TABLE OF CONTENTS EKSWW

Features. 32 Specifications.
Selection data. 34 Dimensional drawing & centre of gravity. 35

Wiring diagram. 36

External connection diagram.
Altherma Sanitary Hot Water
o H y a r m a rA t e0W i h1W nt4S alK- ESA R

Casing Dimensions

Colour Material Packing Height Width Depth Unit Height Width Depth mm mm mm mm mm mm kg kg 45 49
EKSWW150V3 EKSWW200V3 EKSWW300V3 EKSWW200Z2 EKSWW300Z2
Neutral white Epoxy-coated mild steel EPS Carton kg Water volume Material Max. temperat ure Max. water pressure C l Stainless steel (DIN 1.4521) 64

Main components

Insulation
Material Min. thickness mm
Polyurethane foam Stainless steel (DIN 1.4401) 1 kW m inch inch inch inch

EKSWW150V3 EKSWW200V3

Heat exchanger Booster heater
Quantity Material Quantity Capacity

3/4" FBSP 3/4" FBSP 3/4" FBSP 3/4" FBSP
EKSWW300V3 EKSWW200Z2 EKSWW300Z2
Temperature sensor Piping connections
Cable length Water inlet H/E Diameter Water outlet H/E Diameter Cold water in Diameter Hot water out Diameter
Power Supply Phase Frequency Hz Voltage Nominal running current Fuse Size Phase V A A

400 7.2

Selection data
The ALTHERMA by Daikin heat-pump in combination with the optional sanitary tank provide hot water for household usage. The below mentioned data allow a proper selection of the sanitary tank size for maximum comfort and efficiency. (1) Sanitary hot water volume: The volume of hot water available for domestic sanitary usage depends on the physical volume of the sanitary tank, on the sanitary water setpoint temperature and on the temperature spreading in the tank. Therefor we define the equivalent hot water volume (EHWV). Definition: EHWV = The volume of hot water available for domestic sanitary usage at a temperature of 40C. 40C is considered a comfortable sanitary hot water temperature.
Tank 150L 200L 300L Setpoint temp. (C) 75 EHWV (l) 435 Usage pattern Modest + ++ + ++ ++ ++ ++ ++ Medium + + ++ ++ ++ ++ High + ++

++ + -

Excessive availability of sanitary hot water. Sufficient availability of sanitary hot water. Temporary shortage of sanitary hot water can occur. Modest Daily demand up tp 220 l -> typcial 2-persons usage pattern. Medium Daily demand up to 325 l -> typical 3 to 4 persons usage pattern. High Daily demand up to 550 l -> 4 to 6 persons usage pattern.

Usage pattern

(2) Heat-up time: Definition: Heat-up time The time required to reheat the sanitary tank to 55C after tapping a certain volume of hot water at 40C. note: changing the field settings (see installation manual) can influence the heat-up time.
Tank 150L 200L 300L Setpoint temp. (C) 55 Heat-up time for Heat-up time for L (bath) <min> L (shower) <min> 50 30
Conditions for testing: Ta = 7CDB / 6CWB, Troom = 20C, Tstart = 10C, outdoor unit type: ERYQ007
(3) Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system. Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water.

Heat-pump portion

Setpoint temp. (C) Conditions: Real life condition Outdoor temperature Room temperature Outdoor unit type Tank type Field settings Simulation of a daily usage based upon medium usage pattern. 7CDB / 6CWB 20CDB ERYQ007 200l Default field settings (see installation manual).

4TW56719-3

j Water mains in female 3/4 BSP 1 j Water mains out female 3/4 BSP 2 j Thermistor connection female 1/2 BSP 3 j Flow (from hydrobox) female 3/4 BSP 4 j Return (to hydrobox) female 3/4 BSP 5 j Switchbox 6 j Clixon 7 j Connection female 3/4 BSP 8

3TW56714-4

doc1

Renewable energy at its best.

46% savings*

Intelligent Heating System
Reduce your energy consumption simply by replacing your current conventional boiler with an

% of Home Energy use

Standard energy use Altherma kWhr energy savings
Altherma heat pump. Relax in comfort knowing that your household will have considerably lower bills and reduced C02 emissions that are better for our environment. Daikin state-of-the-art air source, air-to-water heat pumps are classified as renewable, low to zero carbon technologies.
Altherma energy savings on whole UK household average energy consumption
*The energy consumption is the average across the UK based on BRE/DTI
information 2003. Altherma energy savings are based on the SAP 2005 default seasonal efficiency of 250% for air-to-water heat pumps. The Altherma will provide more than 250% seasonal efficiency and up to 450% resulting in even further savings.

A. Absorber

B. Boiler

C. Cylinder

( A - Outdoor, B - Indoor, C - Optional for hot water )
The Worlds Leading Manufacturer of Air Conditioning & Heat Pump Technology.
Space Air Europes largest independent distributor of Daikin products.
Wo r k i n g w i t h D a i kin since 1980
www.spaceairsolutions.co.uk

products.

Outdoor Absorber (A)
ERYQ005 (min-nom-max) 4.36 - 5.75 - 7.45kW

Radiator

ERYQ006 (min-nom-max) 4.36 - 6.84 - 8.79kW
ERYQ007 (min-nom-max) 4.36 - 8.43 - 9.58kW Single Phase R-410A -15oC / -20oC 35oC
Dimensions mm (HxWxD) 735x825x300

Space Air Head Office:

Power Supply

Refrigerant

Min. Ambient

Max. Ambient

Efficiency 48 ~ 52 dBA

380% - 430%

floor H

Weight (Kg)

eating
Outdoor Absorber Unit (A) (air-to-water Heat Pump)
Capacities are at BSEN14511 conditions: ambient 7oCDB / 6oCWB, condenser 30oC/35oC *SPL (Sound Pressure Level) at 1m. Night-set back sound reduction of up to 6dBA
can be up to 30m away from Hydro-Box
Hydro-Box Indoor Unit (B)
EKHBH007 875x490x300 Single Phase Not required 40kPa 3 Natural White 25C to 55C 1 BSP

Savings using Altherma

Model (wall mounted)

Dimensions mm (HxWxD)

Condensate Connection
are authorised to certify and train contractors in all Daikin manufactured
can be located in a cupboard or loft, on an internal or external wall
Willway Court, 1 Opus Park, Moorfield Road, Guildford, Surrey GU1 1SZ.
Space Airconditioning plc is an approved Daikin Distributor since 1980, who

Pump Max ESP

Back-up Heater kW

Colour

Water Temp. Range

Water connection 30 61

Refrigerant Pipework

Indoor Hydro-Box (B)

Refrigerant pipe connection 1/4, 5/8

Hot Water Cylinder (C)

Max. RPW* (mtrs)
*RPW: Refrigerant pipe work between Hydro-Box and outdoor unit.
EKSWWU 150 / 200 / / 1150 /3 Single Phase Natural White 40 / 49 / 64

Model (floor standing)

Run cost

Water Volume (ltrs)

55C on its own

Height (mm)

Diameter (mm)

Booster Heater kW

Heating only

CO2 emission

LPG, Oil and Electric boilers

Hot water only

Simply replaces conventional Gas,
High efficiency INVERTER technology
CO2 emission and fuel costs are based on SAP 2005 data. Altherma C02 emissions & running costs are based on 320% seasonal efficiency and economy 7 electricity with 40% off peak. Data is per kW/hr of energy consumed.
The Intelligent Heating System
The First Dedicated Inverter Air-to-Water Heat Pump System
Approved Contractor / Installer:

31% 59%

Heating & Hot water

Tank Weight (Full) (kg)

The Daikin hot water cylinder is optional and is designed specifically for the Altherma heat pump. The electric heater is positioned above the heat exchanger to maximise the efficiency of the heat pump. Cylinder by other manufacturers can be used provided the auxiliary heater is above the heat exchanger and has a sensor pocket. (please contact Space Air for further details).

 

Tags

ICD-SX55 CLP-610ND SEE Seiko 6M15 CD1551B SRF-S53 AGP-V3000 Abm3000 MVC-FD5 Commandos 2 MAG-500 Frontman 15R Ixus 30 500-C WL-1120AP ROC 3205 Device AWF1273 AT3705-DTV RS2052 Smartphone MP-705-2G Kingdom 3-IN-1 Finepix A510 VSX-D938TX KX-TG2740S Duty 2 10 E EMP-1717 VP-D351 HR308 Smart COM WF-611STP PX-120 SSC192 HBH-65 Nakamichi DR-2 Flash SRV-330 X502N VP-D73 Berlin 37x20E MS-03 Abit AS8 Turbo-13R ICF-S79W CPX385W 700R-serials-304051232-thru- ESQ-1 H4150 ZVC190C 10 0 LT4216A Captivate Samsung NV40 ST550 Nomad-JET 100 Review MCD775W KX-FPG378 KMX51 32PW9502-12 KH 2000 Nuvi 750T Oregon 550 TX-29PS10P Motorola Z10 RH461LD UM 076 Autostar497 DSR3009 DPL943 Zanussi T632 MF-14 X363DN TX-L32c10P NV-GS60EB 20LC1RB DMC-TS1 Nokia 3520 Imedia 1517 Express Bizhub C450 Powershot G2 C-160 1000 BE Sports CD-290DJ N676U FO-P610 C3510 S-H509V Fire-36M Shfx71 CDP-XE300 CDX-F5000C ZE4600 Garmin C510 CD163 Hollywood FX

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 