Daikin Inverter Ftxr28EV1B9
|
|
Bookmark Daikin Inverter Ftxr28EV1B9 |
About Daikin Inverter Ftxr28EV1B9Here you can find all about Daikin Inverter Ftxr28EV1B9 like manual and other informations. For example: review.
Daikin Inverter Ftxr28EV1B9 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Daikin Inverter Ftxr28EV1B9 please write about it to help other people. [ Report abuse or wrong photo | Share your Daikin Inverter Ftxr28EV1B9 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(Bulgarian)Daikin Inverter Ftxr28EV1B9, size: 4.9 MB |
Download
(English)Check if your language version is avaliable. Most of manuals are avaliable in many languages. |
Daikin Inverter Ftxr28EV1B9
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
technical data
air conditioning systems
FTXR-EV1B9 R-410A
Split Sky Air
Indoor Units R-410A FTXR-EV1B9
TABLE OF CONTENTS FTXR-EV1B9
Features. 2 Specifications. 3
For indoor units only. Technical Specifications. Electrical Specifications.
Dimensional drawing & centre of gravity. 5
Dimensional drawing. Centre of gravity.
Piping diagram. 7 Wiring diagram. 8
Wiring diagram
Sound data. 9
Sound pressure spectrum.
Split Sky Air Indoor Units
t i y n9 k BU S 1 V r AEt o 0- i o 1R ld 4X npT- FIS R
Features
URURU humidification: maintains a comfortable humidity level without any separate water supply SARARA dehumidification: maintains a comfortable and fresh indoor environment by removing moisture from the air without lowering the temperature Energy efficient: full range A class labels (EER = 5.00/COP = 5.14) Powerful ventilation: refreshes the room within 2 hours Powerful air purification: increases indoor air quality with Daikin Flash Streamer technology Comfortable air flow Stylish design Other features: moisturizing operation mode, breeze cooling air flow, comfort sleep operation, mould shock operation
optional
5 steps
Titanium apatite photocatalytic air purification filter
Specifications
FOR INDOOR UNITS ONLY
Cooling Heating kW kW
FTXR28EV1B9 FTXR42EV1B9 FTXR50EV1B9
Nominal input (Indoor only)
0.030 0.030
FTXR28EV1B9
0.035 0.035
FTXR42EV1B9
0.040 0.040
FTXR50EV1B9
Casing
TECHNICAL SPECIFICATIONS
Colour Packing Height Width Depth Unit Height Width Depth mm mm mm mm mm mm kg kg Length Nr of Rows Fin Pitch Tube type Fin Type mm Nr of Stages mm
White 700/700 2/1 1.2/1.6 20/12 6.35 Hi-XU Multi slit fin Cross flow fan (with saw edge) 1 High Medium Low m/min m/min m/min 11.1 8.8 6.5 5.7 12.4 9.8 7.3 6.5 12.4 9.6 6.8 6.0 12.9 10.2 7.7 6.8 KFD-280-57-8A 5 STEPS , SILENT AND AUTO R-410A rpm rpm rpm 13.3 10.3 7.3 6.5 14.0 11.1 8.3 7.18
Dimensions
Weight Heat Exchanger
Unit Packed Unit Dimensions
Fan Air Flow Rate
Type Quantity Cooling
Silent m/min Operation Heating High Medium Low m/min m/min m/min
m/min Silent Operation Fan Motor Motor Speed (cooling) Model Number of steps High Medium Low
Silent rpm Operation Speed (heating) High Medium Low rpm rpm rpm
Silent rpm Operation Cooling Sound Power Sound Pressure Medium High Medium Low dBA dBA dBA dBA
dBA Silent Operation Heating Sound Power Sound Pressure Medium High Medium Low dBA dBA dBA dBA
Silent dBA Operation Refrigerant Type
Liquid (OD) Gas Diameter (OD) Diameter (OD) Diameter (OD) mm mm mm
Piping connections
6.4 9.5 18
6.4 9.Both liquid and gas pipes Removable/washable/Mildew proof Right, Left, Horizontal, Downward Microcomputer control Installation manual 1 pc. Operation manual
Air Filter
Drain Heat Insulation Air direction control Temperature control Standard Accessories Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity Item Quantity
1 pc. Batteries 2 pcs. Infrared remote control (ARC447A1) 1 pc. Remote control holder 1 pc. Fixing screw for indoor unit 2 pcs. Fixing screw for drain hose 1 pc. Air supply filter 1 pc. Air Supply filter frame 1 set Titanium apatite photocatalytic air purification filter 1 pc. Deodorising filter for streamer 1 pc.
ELECTRICAL SPECIFICATIONS
Name Phase Frequency Voltage Hz V A A A
Power Supply
V50 0.14 0.14 0.4 FOR INTERUNIT WIRING (INCLUDING EARTH WIRING) 220-240 0.16 0.16 0.4 FOR INTERUNIT WIRING (INCLUDING EARTH WIRING) -10% +10% 0.19 0.19 0.3 FOR POWER SUPPLY, 4 for INTERUNIT WIRING (INCLUDING EARTH WIRING) 1 50
Current
Nominal Cooling running current Heating (RLA) Maximum Running Current For Power Supply Quantity Remark
Wiring connections
Voltage range
Minimum Maximum
Dimensional drawing & centre of gravity
Dimensional drawing
(space for performance) 30 Min.
FTXR28-50E
The mark (Y) shows piping direction
Required space for installation
unit (mm)
Air flow (indoor)
Including mounting plate
50 Min. Gear case unit fixed screws (inside panel) (Space for operation) 50 Min. (Space for operation) Room temp. thermistor (side)
Front grill fixed screws (inside panel)
Connection position of humidifying hose
Bottom
Multi-colored indicator lamp / indoor unit ON/OFF switch
Timer lamp Moisturizing lamp Terminal block with earth terminal Signal receiver
Operating state
Gas pipe 9,5 Cut Liquid pipe 6,4 Cut
Drain hose (connecting part I.D. J 14.0, O.D. J 18.0)
Signal transmitter Up/down (automatic) Cooling Dry cooling Dry
Blade angle
Heating Humid heating Humidifying Air purifying Ventilation (Individual operation) Wall hole J70 hole
Approx. 345 Wall hole for embedded piping J70 hole Approx. 395 Approx. 465
Infrared remote control (ARC447A1)
Right/Left (Automatic)
Standard locations of wall holes
3D053944A
Centre of gravity
4D054060A
Piping diagram
Indoor unit
Heat exchanger
Solenoid valve At rated voltage: closed (under dehumidification operation)
Thermistor on heat exchanger
Cross flow fan
Heat exchanger Field piping Single union joint Fan motor
Field piping Single union joint Refrigerant flow Cooling Heating 4D054058A
A1PA5P FG F1U H1P H2PH3P S1C S2C M1F M1SM4S R1T, R2T R1V S1S403,CN1 S1W X1M Y1S,Y2S Z1C : Protective earth : Printed circuit board : Frame ground : Fuse : Multi monitor : Pilot lamp : Limit switch for panel : Limit switch for streamer : Fan motor : Swing motor : Thermistor : Varistor : Connector : Operation switch : Terminal strip : Solenoid valve : Ferrite core
CAUTION
Outdoor
Signal receiver Signal transmitter
Infrared remote control
g Field wiring
Note that operation will restart automatically if the main power supply is turned off and then back on again.
Jumper JA An address setup of remote controller
Transmission circuit
Humidity sensor
Streamer part
High voltage unit
Indoor
3D052768A
Sound data
Sound pressure spectrum
FTXR28E (Cooling) FTXR28E (Heating)
Octave band sound pressure level dB:(0dB = 0.0002 bar)
approximate threshold hearing for continuous noise
3D054041A
Octave band center frequency (Hz)
Operation noise differs with operation and ambient conditions. Measure in anechoic room 1 2
Operation noise differs with operation and ambient conditions. Measure in anechoic room
Legend 50Hz 220-240V (H) 50Hz 220-240V (L)
FTXR42E (Cooling)
FTXR42E (Heating)
3D054042A
FTXR50E (Cooling) FTXR50E (Heating)
Octave band sound pressure level dB:(0dB = 0.0002 bar) Octave band sound pressure level dB:(0dB = 0.0002 bar)
approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise
3D054043A
Split - Sky Air
The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V.
ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.
Daikin units comply with the European regulations that guarantee the safety of the product.
Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.
Daikin Europe N.V. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products.
Naamloze Vennootschap Zandvoordestraat 300 B-8400 Ostend, Belgium www.daikin.eu BTW: BE 336 RPR Oostende
EEDEN07-1011
EEDEN07-101 03/2007 Prepared in Belgium by Lannoo Copyright Daikin
Tags
018CR CDC A071 Kawai CA5 X-905 Sunlite 2004 GT-E1360M E-TEN X800 SA-11S1 KTC-SR901 MRD-M500 JOG50R-2004 MA580 HXA40 AR8390C DAV-LF1 420LTO HT-TZ215R Proxima C420 SG343I Nocturne Longshot Cs6 Nikkor 13 0 SPA1001 CDP-XE370 300 Plus ST305004EXD101-RK AVP-A1HDA 6143 W KX-TG2730S Impressa E40 IFP-120 CD1451B 53 LE26R8 MS-7267 POT 3100 30215 Escort-1996 460UT Podxt PRO EMP-7100 XS-AW3 Software PD-S505 CJ-N77CL TCP58S1 13420 W DMR-EX77 DEH-P3150 Review KXL-600A Kxtcd220G Nygk-G1500E12 HT820 HF R16 WBU910 D915GEV L2323T KX-TGA820EX DK-A1 Schtb10EG WS-32Z419T 125 S DV1000 HT-C453 Fishfinders DEH-P9200R WD-N80090U EP4000 The Past STR-DE695 MHC-RX900 Veriton M410 GR-L218STB Pickup AR-168D Photophone Ixus 300 DCR-HC16E Aquabeat Webster LS-H246tnb0 FP91G P VR686 60840 DSC-W360 NWZ-W202 RS21fcsm LA40A610a3R Strav720 Acoustics GT40 VN-6200PC OFX 1200 NEC LT10 Satellite A20 Premier 520 37LG20 YFZ450-2005 82999 DRC8310N M-audio BX5A
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101