Reviews & Opinions
Independent and trusted. Read before buy Delonghi Pinguino L20H!

Delonghi Pinguino L20H

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Delonghi Pinguino L20H, size: 534 KB
Instruction: After click Download and complete offer, you will get access to list of direct links to websites where you can download this manual.

About

Delonghi Pinguino L20HAbout Delonghi Pinguino L20H
Here you can find all about Delonghi Pinguino L20H like manual and other informations. For example: review.

Delonghi Pinguino L20H manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Delonghi Pinguino L20H please write about it to help other people.

 

[ Report abuse or wrong photo | Share your Delonghi Pinguino L20H photo ]

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 3. Page 1 of 1. Average Rating:
info_web 8:31am on Thursday, September 9th, 2010 
Incapable of cooling one bedroom below 25 degrees The manual even says that the "ideal" operating temperature is something like 25 degrees - which isn...
TobbeW 5:40pm on Tuesday, July 13th, 2010 
It is effective. it cools a hot, humid room in seconds A bit nosiy but not so it is unbearable It is effective. it cools a hot, humid room in seconds A bit nosiy but not so it is unbearable
bhayes 10:13pm on Friday, July 2nd, 2010 
air conditioner The air conditioner came very promptly. It was simple to set up and works very well.

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

Descrizione Description Description Beschreibung Beschrijving Descripcin Descrio
ACCESSORI ACCESSORIES ACCESSOIRES ZUBEHR ACCESSOIRES ACCESORIOS ACESSRIOS
TIMER ON TIMER OFF COOL FAN

AUTO HIGH MED LOW

ON/OFF

Warnings

ENGLISH
This appliance is designed for home air conditioning and must not be used for other purposes. It is dangerous to modify or alter the characteristics of the appliance in any way. The appliance must be installed in conformity with legislation in force in the country concerned. If the appliance requires repair, contact a Service Centre authorised by the manufacturer only. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This air conditioning unit must be used by adults only. Never allow children to play with the appliance. This appliance is designed for home air conditioning and must not be used for other purposes. Do not allow children to play with the appliance. The appliance must be connected to an efficient earth system. Have your electrical circuit checked by a qualified electrician. Do not use extension cables. Before cleaning or maintenance operations, always unplug the appliance from the mains socket. Do not move the appliance by pulling the power cable. Do not install the appliance in rooms containing gas, oil or sulphur. Do not install near sources of heat. Do not rest heavy or hot objects on top of the appliance. Clean the anti-microbial filters at least once a week. Avoid using heating appliances near the air conditioning unit. Always transport the appliance upright or resting on one side. Use the appliance as described in this instruction manual only. As with any electrical appliance, while the instructions aim to cover as many eventualities as possible, caution and common sense should be used when operating and installing this air conditioning unit. At the end of its working life, take the appliance to a special collection centre. The materials used for packaging can be recycled. You are therefore recommended to dispose of them in special differentiated waste collection containers. When putting the appliance away, do not cover with plastic bags. The refrigerant gas R407c conforms to EC regulations on the environment. Avoid perforating the refrigerant circuit of the appliance. Keep the appliance at least 50 cm away from flammable substances (alcohol etc) or pressurised containers (e.g. aerosol cans).

DESCRIPTION 1 air outlet grille
control panel castors handles evaporator air intake grille air exhaust hose housing condenser air intake grille drain hose cover power cable flange cap air exhaust hose
window outlet suckers castor locks remote control unit (model L30/L40only)
What are the Pinguino and SuperPinguino?
uring the summer, you feel comfortable at a temperature of between 24 and 27 C with a relative humidity of about 50%. An air conditioning unit removes excess moisture and heat from the room where it is located. Compared with installed models, portable air conditioning units have the advantage that they can be moved from one room to another in the home or be transported from one building to another. Hot air from the room is passed through a coil cooled by refrigerant gas. Excess heat and moisture are removed before the air is re-emitted into the room. In single unit models (Pinguino), a small part of this air is used to cool the refrigerant gas and then, when hot and damp, is discharged outside. In models with case (SuperPinguino), the circuit is cooled using air from outside. All Pinguino and SuperPinguino models can also be used in fan-only mode.
Pre p a r i n g f o r u s e
ELECTRICAL CONNECTIONS Before plugging the appliance into the mains socket, check that: the mains power supply corresponds to the value indicated on the rating plate on the back of the appliance; the mains socket and electrical circuit are adequate for the appliance; the mains socket matches the plug. If this is not the case, have the plug replaced; the mains socket is adequately earthed. Failure to follow these important safety instructions absolves the manufacturer of all liability. The power cable must be replaced by a qualified professional only.
The instructions below will enable you to prepare your air conditioning unit for operation as efficiently as possible. Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is ensured with Pinguino: Fit the air exhaust hose 11 in the housing

at the back of the appliance. Insert it as

shown in figure A.

If you have a double window, use the suckers 13 provided to hold the two parts of the window together (fig. C).
Fit the window outlet 11 to the end of the hose 12. Place the air conditioning unit near a window or French window. Make sure the air exhaust hose is unobstructed. Open the window or French window slightly and position the outlet 12 as shown in figure B. Keep air hoses as short and free of curves as possible to avoid constrictions.
AIR-CONDITIONING WITH INSTALLATION
If required, the Pinguino can also be installed semi-permanently (Fig. D). Fit the flange accessory the hole

provided in

Fit the hose 11 in the housing at the back of the appliance (fig. A page 21). Fit the end of the hose 11 to the flange

10 as shown in fig. F.

MAX100 cm

MIN 35 c

Proceed as follows: Drill a hole in an outside wall or through a window pane. Respect the height and dimensions of the hole given in figure E. When the hose 11 is not fitted, the hole can be closed with the flange cap
NOTE. When installing the air conditioning unit semipermanently, you should leave a door slightly open (as little as 1 cm) to guarantee correct ventilation.

in the window pane

in the wooden kickboard of a French window
in the wall: you are recommended to insulate the section of wall using suitable insulation.
Keep the air hoses as short and free of curves as possible to avoid constrictions.
Control panel L10/L15/L20H

MODELS L10/ L15/L20H

THE CONTROL PANEL
DESCRIPTION OF THE CONTROL PANEL A ON/OFF button B Mode selection button Conditioning, fan, heating (L20H only). C Air conditioning mode indicator light D Fan mode indicator light E Heating mode indicator light (L20H only) F Increase temperature/ programmed operating time button G Timer in operation indicator light H Display Displays the temperature values set and the programmed operating time I Reduce temperature/humidity/programmed operating time button L/M/N/O Fan speed and AUTO mode indicator lights P Fan speed selection button Q Timer button

L10/ L15/ L20H operation

TURNING THE APPLIANCE ON
Plug the appliance into the mains. Two lines appear on the display indicating that the appliance is in standby. Press the ON/OFF button (A) (when turned on, the air conditioning unit starts operating in the same mode as when it was turned off). Press the MODE (B) button until the indicator light corresponding to the required mode lights up: Indicator light (C): Indicator light (D): Indicator light (E) : air-conditioning mode fan mode heating mode (model L20H only)

AIR-CONDITIONING MODE

Ideal for hot humid weather when you need to cool and dehumidify the room. To set the operation of the appliance correctly, press the + (F) or - (I) buttons until the desired temperature is displayed. Then select the fan speed by pressing the FAN button (P) until the indicator light corresponding to the required fan speed lights up MAX: the air conditioning unit operates at maximum to reach the required temperature as rapidly as possible MIN: reduces noise levels but still maintains a good level of comfort QUIET: for silent operation AUTO: the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display. The most suitable temperature for the room during the summer varies from 24 to 27C. You are recommended, however, not to set a temperature much below the outside temperature.

FAN MODE

HEATING MODE (MODEL L20H ONLY)
To set operation of the appliance correctly, press the + (F) or - (I) buttons until the desired temperature is displayed. In heating mode, the fan speed is selected automatically by the appliance. The AUTO light (O) on the control panel comes on.

SETTING THE TIMER

The timer can be used to delay appliance start up or shut down. This avoids wasting electricity by optimising operating periods How to programme delayed start up Plug the appliance into a mains socket and press the ON/OFF (A) button, then select the required operating mode and other settings (temperature, fan speed, etc). Press the ON/OFF (A) button again to place the appliance in standby mode. Press the timer button (Q). The two centre segments flash on the display. Use the + (F) o - (I) buttons to set the number of hours delay before the appliance comes on. The setting is increased or decreased by an hour at a time; however, when the buttons are held down for more than two seconds, the time runs rapidly up to a maximum of 24 hours. Wait a few seconds for the data to be acquired. The indicator light (G) flashes until the appliance starts up. You can set the appliance to come on with a delay of up to 24 hours. To cancel the timer setting, press the timer button (Q), and use the - button (I) to set the time to zero. The indicator light (G) will stop flashing. How to programme delayed shut down Delayed shut down can be programmed in any operating mode (air conditioning / fan / heating) (model L20H only). Press the timer button (Q). The two centre segments flash on the display. Use the + (F) o - (I) button to set the number of hours delay before the appliance goes off. The setting is increased or decreased by an hour at a time; however, when the buttons are held down for more than two seconds, the time runs rapidly up to a maximum of 24 hours. Wait a few seconds for the data to be acquired. The indicator light (G) flashes until the appliance shuts down. To cancel the timer setting, press the timer button (Q), and use the - button (I) to set the time to zero. The indicator light (G) will stop flashing.

Adjust fan speed by pressing the FAN button (P) as described for the air-conditioning mode. Remember that the higher the speed, the more air is filtered. If you select "Quiet" speed, less air is filtered but the appliance is also less noisy. In this mode, AUTO cannot be selected. The fan speed selected will be displayed.
L10/L15/L20H self diagnosis

SELF DIAGNOSIS

The appliance has a self diagnosis system to identify a number of malfunctions.

WHAT SHOULD YOU DO?

LOW TEMPERATURE (frost prevention) When the appliance is operating in air conditioning mode, this device prevents the formation of ice. The appliance starts up again automatically when the defrosting process is completed. If this alarm appears, contact the service centre. Empty the internal safety tank, through the drain hoses. (see page 31 end of season operations.
p f PROBE FAILURE (The probe is damaged)
FULL TANK (The tank is full)

Control panel L30/L40

MODELS L30/L40 ENGLISH
R Z S DESCRIPTION OF THE CONTROL PANEL R Air-conditioning/fan mode indicator light S Timer indicator light T Remote control receiver U Full tank alarm indicator light V Power indicator light Z Mode selection button CORRECT USE
Point the remote control at the receiver (T) on the air-conditioner. Maximum distance: around 7 metres (without any obstacles between the remote control and the receiver). The remote control should be handled with extreme care and respect: do not drop it, expose it to direct sunlight, or leave it near sources of heat.
DESCRIPTION OF THE REMOTE CONTROL 16) FAN button 17) ON/OFF button 18) MODE button 19) TIMER button 20) Display
THE REMOTE CONTROL Remove the cover on the rear of the remote control; Replace the old batteries with two new 1.5V R03 AAA batteries, inserting them correctly (see the instructions inside the battery compartment); Put the cover back on. When both replacing and disposing of the remote control, the batteries must be removed and disposed of according to the laws in force, as they are harmful to the environment.

L30/L40 operation

Plug the appliance into the mains. Press the ON/OFF button (17) (when turned on, the air conditioning unit starts operating in the same mode as when it was turned off). Press the MODE (18) button to select the required mode AIR-CONDITIONING (COOL) FAN ONLY (FAN) An arrow on the display indicates the selected mode.
AIR-CONDITIONING MODE (COOL)
Ideal for hot humid weather when you need to cool and dehumidify the room. In air-conditioning mode, use the buttons to select the desired temperature. The display shows the set temperature. To change the fan speed, use the FAN button (16) on the remote control, choosing from the available speeds: LOW: MED: HIGH: for silent operation reduces noise levels but still maintains a good level of comfort the air conditioning unit operates at maximum to reach the required temperature as rapidly as possible AUTO: the appliance automatically selects the most suitable fan speed in relation to the temperature set on the digital display. The most suitable temperature for the room during the summer varies from 24 to 27C. You are recommended, however, not to set a temperature much below the outside temperature.

FAN MODE ONLY

In fan mode, the fan speed can be set by pressing the FAN button (16). The fan speed changes between the speeds available (LOW/MED/HIGH). An arrow on the display indicates the set speed. Remember that the higher the speed, the more air is filtered. If you select "LOW" speed, less air is filtered but the appliance is also less noisy. In this mode, AUTO cannot be selected.
The timer can be used to delay appliance start up or shut down. This avoids wasting electricity by optimising operating periods. Programming delayed shutdown With the air-conditioning unit on, press the TIMER button. The time is displayed and the h symbol flashes, with a flashing arrow indicating TIMER OFF. Set the time when you want the appliance to go off using the buttons (from 30 minutes to 24 hours). During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected. Press the TIMER button again to confirm the selection. (A beep sounds and the timer light (S) on the control panel comes on to confirm the setting of the timer). A countdown of the time left is displayed. At the end of the set time the appliance switches off automatically. To cancel the set time, press the TIMER button again: a beep will sound and the light (S) on the control panel will go off.

Programming delayed start-up With the air-conditioning unit off, press the TIMER button: the display shows a flashing arrow indicating TIMER ON. Now make all the desired settings for when the appliance will switch on (operating mode, fan speed and temperature). Confirm the settings by pressing the TIMER button. The time is displayed and the h symbol flashes. Set the time when you want the appliance to switch off using the buttons (from 30 minutes to 24 hours). During the first ten hours, you can select half hour intervals. For times greater than ten hours, one hour intervals can be selected. Press the TIMER button again to confirm the start-up time. A beep sounds and the timer light (S) on the control panel comes on to confirm the setting of the timer. A countdown of the time left is displayed. At the end of the set time the appliance switches on automatically, with the settings made previously. To cancel the set time, press the TIMER button again: a beep will sound and the light (S) on the control panel will go off.
The appliance has a self diagnosis system to identify a number of malfunctions. If these faults occur, the air-conditioner will shut down.

IF THE LIGHT (U).

FLASHES TWICE (The tank is full)
Empty the internal safety tank, through the drain hoses. (see page 31 end of season operations
FLASHES ONCE (The probe is damaged)
If this alarm appears, contact the service centre.
To get the best from your air conditioning unit, follow these recommendations: close the windows and doors in the room to be air conditioned. The only exception is when the appliance is installed through a hole in the wall. In this case, you are recommended to leave a slight draught through a door or window to guarantee correct ventilation. Never use the appliance in very damp rooms (laundries for example). Never use the appliance outdoors.

close doors and windows

Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to make the appliance much more economical to run; Never rest objects of any kind on the air conditioning unit; Never obstruct the air intake 5 or outlet 1 grilles;; Make sure there are no heat sources in the room.

close blinds or curtains

Make sure the air conditioning unit is on a level floor. If necessary, place the two castor locks 14 under the front wheels
do not cover the appliance

Cleaning

Before cleaning or maintenance, turn the appliance off by pressing the ON/OFF button (A) (in models L10,L15 and L20H) or button (17) on the remote control (in models L30 and L40) and always unplug the appliance from the mains socket. CLEANING THE CABINET You should clean the appliance with a slightly damp cloth then dry with a dry cloth. For safety reasons, never wash the air conditioning unit with water. Precautions Never use petrol, alcohol or solvents to clean the appliance. Never spray insecticide liquids or similar. CLEANING THE AIR FILTERS To keep your air conditioning unit working efficiently, you should: Clean the dust filter every week of operation. The filter is housed in the intake grille. To clean the filters, proceed as follows 1. Remove the intake grille by rotating outwards (Fig. G). Use a vacuum cleaner to remove the dust collected on the filter. If it is very dirty, immerse in warm water and rinse a number of times. The water should never be hotter than 40C. After washing, leave the filter to dry. To replace, put the filters back in the intake grille then attach the intake grille to the appliance. START OF SEASON CHECKS Make sure the power cable and plug are undamaged and the earth system is efficient. Follow the installation instructions precisely.

END OF SEASON OPERATIONS To empty the internal circuit completely of water, open the cover (8) on the rear of the appliance. Pull out the 2 drain hoses, take off the caps and let all the residual water flow out (fig.I). When all the water has been drained, place the caps back on the hoses and put the hoses back inside. Clean the filters and dry thoroughly before putting them back.
2. Remove the dust filter by detaching it from the grille (Fig. H).
intake grille dust filter

Troubleshooting

PROBLEM
The air conditioning unit does not start
no electricity it is not plugged into the mains the safety device has tripped

REMEDY

wait plug into the mains contact your service centre
The air conditioning unit works for a short time only
the air exhaust hose has a constriction the air exhaust hose is blocked there are bends in the air exhaust hose window open there are heat sources in the room (burner, lamp, etc) the exhaust hose is detached air filters clogged the air conditioning unit is not powerful enough for the conditions or size of the room
position the exhaust hose correctly check there are no obstacles obstructing air discharge eliminate the bends close the window eliminate the heat source connect the exhaust hose clean or replace the filters
The air conditioning unit works, but does not cool the room
Particular odour in the room

air filter clogged

clean or replace the filter
The air conditioning unit does not operate for about three minutes after turning it on. / PF/ appears on the display (models L10/ L15 and L20H only) The U-tank alarm light flashes on the control panel (models L30 and L40 only)
the safety device has tripped

wait for three minutes

See "self-diagnosis" section
Guarantee/technical specification
GUARANTEE AND TECHNICAL ASSISTANCE
The conditions of the guarantee and technical assistance are given on the certificate supplied with your appliance.

TECHNICAL SPECIFICATION

Power supply voltage Max. power input during air conditioning Max. power input during heating (mod. L20H) Refrigerant Cooling capacity see rating plate

LIMIT CONDITIONS

Temperature of the air-conditioned room

21 - 35C

Temperature of the air-conditioned room (Mod. L20H) max. 25C
Appliance dimensions: width height depth weight
505 mm 825 mm 440 mm 34 kg
Transport, filling, cleaning, recovery and disposal of refrigerant should be performed by a technical service centre appointed by the manufacturer only. The appliance should be disposed of by a specialist centre appointed by the manufacturer only.

 

Tags

Comfort TM 808 Phase26USB UX-W70CL 732NW Cingular 3125 Samsung A800 Mazda 3 728 Plus MHC-DX30 F1403FD Tomydoo WD-80150TP R-1505 CFD-S20CP Falcon PD250 MDX-C6500RV TE300 RCM 127 USA 850 145 D Classpad 300 UX-H30 Review C1900 XSU-01220B RM-V701 Portege 4000 Mg12 4 Atapi CDX-F5505X A7V266-EX CDA-5755 EWR10D5 Aficio 1515 MHC-RX88 B-SP2D Series Cappuccino Ecowater E17 AFC90100X Translator DSC-T1 C-180 ES 80 LRH-790 EMX2300 CY-TUP153N - 2002 Supreme KV-SZ29m91K Guide DSC-HX5v B B8300 Touch 355 4 2 FE-4020 PD-6006 SP-565UZ DES-5200 Template U7-132 ZSR0104DE XD-553 DGB-500 PM1000 Pacific STR-DE635 Boost IS F WL-500W Mcbr360S Transsport 1998 GR-DX27 P6250 16 JBC Micro-ondes LG 200 CS5MX BCR 2000 Lexmark Z43 Cvp-83 X3-02 I8000H Avtl 89 PFM-50C1 Fire-18M DC-210 DSC-T900 32PG6000 Acerpower M6 Coolpix S520 KX-TCA120EX HM100JC 161SPF Dvcr-B100 SV0602H DSC-T9 Strategy SHS-10

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 