Reviews & Opinions
Independent and trusted. Read before buy Devi Devireg 850!

Devi Devireg 850


Bookmark
Devi Devireg 850

Bookmark and Share

 

Devi Devireg 850About Devi Devireg 850
Here you can find all about Devi Devireg 850 like manual and other informations. For example: review.

Devi Devireg 850 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Devi Devireg 850 please write about it to help other people.
[ Report abuse or wrong photo | Share your Devi Devireg 850 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (German)
Devi Devireg 850, size: 1.5 MB
Download (English)
Check if your language version is avaliable.
Most of manuals are avaliable in many languages.

 

Devi Devireg 850

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

Devireg 850 ice and snow melting
Ground and/or roof systems (1 - 4 sensors)

Applications:

Devireg 850 is efficiently controlling ice and snow melting systems in: Driving areas Ramps Stairs Driveways Pavements Parking areas Doorways Loading areas Bridges Car parks Roofs Roof gutters Zone support saves energy. The Devireg 850 lets you divide your area into 2 zones, eg. a North and South side. In this way it is possible to save energy, when the South side is free of ice and snow faster because of the heat from the sun. You can also prioritize between the zones, eg. if you have limitited power output. This way one zones is made ice and snow free before focus is put on the other zone. With the Devireg 850 you can make 2 zones with ground sensors, 2 zones with roof sensors, or 2 zones with both ground and roof sensor, making the products both match the needs of the residential and commercial applications. The Devireg 850 is the most optimal solution for keeping an area free of ice and snow. Devireg 850 acts on information received from the sensor(s) which register both temperature and moisture. Devireg 850 calculates the information and secures that the heat only will be turned on when the right combination of low temperature and a certain level of moisture are detected. This gives an energy saving system and reduces running costs. If correctly adjusted, you can save 60% on ground systems and 40% on roof systems on operating costs compared with a simple air temperature thermostat.

www.devi.com

Functions:
Multiple languages in illuminated display. Info-button for help/information. The info-button will guide you through the menus and settings. View the actual temperature and moisture level measured by the sensors. Adjustable operation mode: Automatic, constant on, and constant off. Adjustable parameters: Melting temperature, standby temperature, moisture sensibility, post heating period. The Intelligent, digital sensors will reduce energy consumption and give an optimal protection. The sensors are easy to install and designed for rough weather and heavy traffic loads. Devibus enabled. Connect all sensors in parallel. Zone support combined system (2 systems in one) ground and roof 2 similar zones either ground or roof (eg. north/south) saving energy Prioritizing one zone over other eg. for installations with limited power allocation Fault finding programme. The Devireg 850 has a self diagnosing programme, which will detect faults and give an alarm. Alarm function. Blinking red light and a sound will indicate an alarm. Possibility of connecting external alarm. RS232 enabled. Connect the Devireg 850 to a computer when a software upgrade is available.

Technical Specification

Technical data Voltage: Devireg 850 Power supply Power consumption: Devireg 850 Roof sensor(s) Ground sensor(s) Relay load capability: Resistive load Alarm realy Resistive load System A relay Resistive load System B relay Inductive load each realy IP class: Devireg 850 Roof sensor(s) Ground sensor(s) Ambient temperature: Devireg 850 Roof sensor(s) Ground sensor(s) Sensor type: Indication: 18-26 VDC 180-250 VAC, 50/60 Hz Max. 3 W Max. 8W (each) Max. 13W (each) 230V ~ 2A 230V ~ 15A 230V ~ 15A 1A (power factor 0.3) IP 20 IP 67 IP 67 -10C to +40C -50C to +70C -30C to +70C Devibus connected moisture sensor(s) 2 x 16-character illuminated display Alarm light (red) Lit info key (yellow) (Depth x Height x Width) 53 mm x 86 mm x 105 mm 15 mm x 23,5 mm x 216 mm D = 87 mm; height = 74 mm D = 93 mm; height = 98 mm
Measurements: Devireg 850 Roof sensor(s) Ground sensor(s) Tube ground sensor(s)

A Wiring diagram

Devireg 850

250V~2A

250V~15A

System A

System B
DEVI A/S Ulvehavevej 61 DK7100 Vejle Tel.: Fax: +00 +01

VLCKH102 Danfoss 06/2007

doc1

devireg 850 ice and snow melting
Ground or roof systems (1 - 4 sensors)

Applications:

devireg 850 is efficiently controlling ice and snow melting systems in:

Driving areas Ramps Stairs Driveways Pavements Parking areas Doorways Loading areas Bridges Car parks Roofs Roof gutters
The devireg 850 is the most optimal solution for keeping an area free of ice and snow. devireg 850 acts on information received from the sensor(s) which register both temperature and moisture. devireg 850 calculates the information and secures that the heat only will be turned on when the right combination of low temperature and a certain level of moisture are detected. This gives an energy saving system and reduces running costs.

www.devi.com

Functions:
Multiple languages in illuminated display. Voltage Power consumption devireg 850 Sensor(s)
Technical data 230 VAC +10%/-20% Max. 3 W Ground: max. 13W, roof: max. 8W 250V ~ 16A 1A (power factor 0,3) IP 20 IP 67 -10C to +40C -30C to +70C -50C to +70C devibus connected moisture sensor(s) 15 m of 4x1mm2 2x16-character illuminated display. Depth x Height x Width 53 mm x 86 mm x 105 mm D = 87 mm; height = 74 mm D = 93 mm; height = 98 mm 15 mm x 23,5 mm x 216 mm
Info-button for help/information. The info-button will guide you through the menus and settings. View the actual temperature and moisture level measured by the sensors. Adjustable operation mode: Automatic, constant on, and constant off. Adjustable parameters: Melting temperature, standby temperature, moisture sensibility, post heating period. The Intelligent, digital sensors will reduce energy consumption and give an optimal protection. The sensors are easy to install and designed for rough weather and heavy traffic loads. devibus enabled. Connect all sensors in parallel.
Relays (all incl. alarm) Resisitive load Inductive load IP class devireg 850 Sensors Ambient temperature devireg 850 Sensor - ground: Sensor - roof: Sensor type Sensor lead Indication Measurements devireg 850 (DIN rail) Sensor - ground Sensor tube - ground Sensor - roof
Fault finding programme. The devireg 850 has a self diagnosing programme, which will detect faults and give an alarm. Alarm function. Blinking red light and a sound will indicate an alarm. Possibility of connecting external alarm.
RS232 (for software upgrades)
RS232 enabled. Connect the devireg 850 to a computer when a software upgrade is available.

DC supply

Ground
DEVI A/S Ulvehavevej 61 DK7100 Vejle Tel.: Fax: +00 +01

 

Tags

DVP435E 4FAC-485 Desktop S520 ES-4033 5440 DL U8380 I PMX 250 SX-F AG-DVX100B MAC 500 GSA-4166B AR 638 G31-M7 TE Review Joybook 5000 KC-C70 TW911P2 MHC-RG77 Anti-calc AX339CA Sagem D86C C5045 Piccolos MX-KB4 FE1205 Tycoon PS2 ICO KX-TCD230HG Fo-p610 DP231 LD2940 ZSF4143 Desktop MX 495309 Pcwa-A220 CM 127 R-898 Cyclecomputing Z3 MHC-BX3 LV-X2 BLC1A WS-7013U CU-2E15GBE 26HF7875-10 042511 DVR-330-S Hiace DCR-DVD304E Purple RP-54NA20P CBR 2 Sc-1100 DV8631V Multiview PCG-Z600TEK LAC4810 C6500E SGH-C210 L1910B Mamiya ZD RP7494 Proel M-8 Meade DSI 52-16 Doro 8075 EWF10240W CX-integrator V2 Machine MT 975 Break W220D Hunter 5600G Phonefax 33S LN19R71B Pentax K2 Plantronics CS60 B36ahyuh61 SC-EN17 ME6124W System Nokia 5800 CD1503B ZWS3102 4400F BTM630 12 KX-TCM420B FX-911W 37 TS KLV-32M1 F601M IVA-W200 GR-292SQA EC 155 Audioline WT50 PM-90SE SUP021YR Plantronics A100 RW701 CK460C USR8700

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101