Durst Laborator 1840
|
|
Bookmark Durst Laborator 1840 |
About Durst Laborator 1840Here you can find all about Durst Laborator 1840 like manual and other informations. For example: review.
Durst Laborator 1840 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Durst Laborator 1840 please write about it to help other people. [ Report abuse or wrong photo | Share your Durst Laborator 1840 photo ]
Manual
Download
(English)Durst Laborator 1840, size: 6.2 MB |
Durst Laborator 1840
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
Durst Laborator 1840
The supremely versatile enlarger
-from smallest films to giant enlargements
Add to the Laborator 1840 a CLS 1840 colour head (with 1000 watt lamp), a roll paper easel and the Durst PCM 1001 - and you truly have the most efficient and most versatile darkroom unit. For with this combination you handle every type of order, from the smallest standard print to professional giant enlargements and strip prints. The manual tilt movements of the enlarger head, lens standard and baseboard allow easy correction of converging verticals or deliberate distortion effects.
CLS 1840
Colour head
Applications: From reductions to poster prints, to giant enlargements, by simply swinging the enlarger head for horizontal projection. Tightly cropped partial enlargements, transparency duplication, combination printing in register etc. Even illumination with format-matched mixing boxes.
High filter densities Yellow, magenta and cyan dichroic filters with settings up to 130 densitometric values plus supplementary 70 Y and Short exposures even at high magnifications with 30 M filters cope easily with difficult originals. the 1000 watt tungsten-halogen lamp and interchangeable double mixing boxes matched to Preferred optimum exposure times and apertures the film size in use - 25x25, 20x25, 13x18, 10x12.5 at low magnifications with stepless density and 6x9 cm (10x10, 8x10, 5x7, 4x5 and 2 1/4x3 1/4 diaphragm (range 0 to 60, or 2 f-stops). in.), also 24x36 mm - for most efficient light use. Special strip mixing boxes greatly reduce
http://www.colex.com/durstlab18.html (1 of 6) [8/8/2001 1:48:32 PM]
Easy focusing with white-light lever to swing filters and density diaphragm out of the light path.
exposure times for strip enlargements by concentrating the light on the film strip area being projected. This can halve the exposure and achieves more even illumination with better colour mixing. Specially suitable for horizontal projection (see technical data).
CLS 2000
Applications Enlargements, reductions, horizontal High filter values up to 130 densitometric values projection, transparency duplication, combination with stepless dichroic filter settings. Supplementary 20 M and 45 Y filters are built in for negatives printing etc. needing extreme correction. High light output The 2000 watt tungsten-halogen Density diaphragm avoids excessively short lamp with separate diathermic reflector and the exposure times at low magnifications and double format-matched mixing boxes yield compensates reciprocity failure. The setting range maximum light output with optimum colour mixing. This ensures very short exposure times - a of 0 to 60 covers 2 f-stops. special boon with horizontal projection for giant enlargements. Efficient cooling system Two fans - one for the lamp area including the heat filter and dichroic filters, the other for the film carrier, mixing boxes The voltage stabilizer compensates voltage and diffuser - prevent harmful heating of films even fluctuations from +10% to -15% with continuous operation. The fans keep running until the lamphouse has cooled to ambient Optimum colour temperature even with short temperature. exposure times. The voltage stabilizer controls a shutter that only opens when the preheated tungstenhalogen lamp has reached its correct colour temperature. After the exposure the shutter automatically closes and the lamp returns to preheated standby mode.
Basic enlarger
Features
Rigid construction for maximum stability. The solid column design maintains precise alignment of the
http://www.colex.com/durstlab18.html (2 of 6) [8/8/2001 1:48:32 PM]
three principal planes. Horizontal projection. It's rigid construction makes the Laborator 1840 specially suitable for horizontal projection. For easy movement in such a setup we recommend installing the enlarger on rails. Full distortion control. The independent tilt facility of the three principal planes (baseboard, lens plane and enlarger head with film plane) corrects converging verticals or provides deliberate distortion. Scales simplify repeat settings. Motorized enlarger head and lens movement. A central control panel controls these functions. It also stores exposure times and triggers the exposure via the digital timer. Roll paper easel operation. The baseboard carrying arm is easily removed, for using a roll paper easel.
Accessories
1) ROLLFILMNEG 1840 Consists of an adapter with adapter mixing box and BIMANEG negative carrier (rotates through 90 degrees, normally supplied with two glass plates). Particularly suitable for rapid enlargements from films up to 6 x 9 cm, especially with roll paper easels. Two laterally adjustable masking plates mask down the film to the required strip. The basic NEGATEIL 1800 N includes a register pin bar for the Durst LORVALO system. The Durst MIVALO register system (MIVADAP 205) and the American Kodak system (KODAREG 165 V) are available separately.
BINEMA metal masks for film sizes from 24 x 36 5) PCM 1001 -Serves as a colormeter to establish filter settings mm to 6 x 9 cm (ROLLFILMNEG 1840 and exposure times, allowing for reciprocity failure accessories). effects. -Also as Photometer for slide duplication. 2) BIMABOX 35 N, 69 N Mixing boxes for film sizes from 24 x 36 mm to 6 -And as VCNA translator -Permits spot or full-area readings. x 9 cm (ROLLFILMNEG 1840 accessories). -Automatically compensates for reciprocity failure. HOMASKSET Format masks for film sizes from 24 x 36 mm up to Please ask for the PCM 1001 booklet. 20 x 25 cm with the LARANEG negative carrier 6) LARABOX 100 N, 138, 450, 69, 35 for film (mounted below lower glass, permit use of two sizes from 24 x 36 mm to 20 x 25 cm negative carrier glasses).
http://www.colex.com/durstlab18.html (3 of 6) [8/8/2001 1:48:32 PM]
TRINOMASK 35 N, 66 N, 67 N, 69 N Format masks (24 x 36 mm up to 13 x 18 cm) fitted with guide pins on springs. Permit the use of a glass or anti-Newton glass plate in place of the upper format mask for occasions where absolute film flatness is vital.
7) LARABOX 256, 186, 126 for strip exposures with film sizes from 10 x 12.5 to 20 x 25 cm (4 x 5 to 8 x 10 in.). 8) NEGAROLL 205 for rapid operation with aerial films and film rolls up to 240 mm (9 1/2 in.) wide and 60 m or 200 ft long.
LARATRINO Pair of reducing adapters for faster operation with 9) MIVALO micro precision register system for the LARANEG carrier with TRINOMASK format register operations with the standard LARANEG masks. and the NEGATEIL 1800 N negative carriers - VAPLA lens board for 300 and 360 mm lenses. 3)LARANEG - TRIPLA lens turret for three lenses from 100 to Negative carrier equipped with two register pin 240 mm. bars (Durst LORVALO and Kodak Register - UNIPLA lens board for lenses from 100 to 240 systems). mm. 4) NEGATEIL 1800 N Special negative carrier for strip exposures with horizontal projection, for film sizes up to 20 x 25 cm. Lateral knobs can shift the inner film holder out of the optical axis by up to 120 mm to the left or right. That allows attachment of the enlarging paper in the same spot on the easel every time. 10)DESKMES 1000 remote control unit for enlarger head and lens plate adjustment.
Technical data
Overall height with CLS 1840: approx. 281 cm (111 in.)
CLS 1840 colour head
CLS 2000 colour head
Light source: 230V 2000W tungsten-halogen lamp AC mains supply: - stabilised EST 2000 mains transformer - Nominal voltage 220/240V, 50-
Light source: 120V 1000W Overall height with condenser tungsten-halogen lamp unit: approx. 270 cm (106 in.) AC mains supply: Optical axis/column distance: - stabilised EST 1000 mains transformer approx. 49.5 cm (19.5 in.) - Nominal voltage 220/240V, 50-
http://www.colex.com/durstlab18.html (4 of 6) [8/8/2001 1:48:32 PM]
Lowest optical axis level with horizontal projection: approx. 130 cm (19.5 in.) Floor space requirement: approx. 140 x 140 cm (55 x 55 in.)
60Hz - Stabilising range 180-260V - Output voltage of EST 1000: 120V +-1% Power consumption: 1200 watts
60Hz - Stabilising range 180-260V - Output voltage of EST 2000: 228V +-1V Power consumption: 1200 watts Filters: Dichroic, up to 130 densitometric values Supplementary filters: approx. 45 Y and 20 M Density diaphragm 0 to 60 (= 2 f-stops) Size: approx. 60 x 55 x 65 cm (23.6 x 21.6 x 25.6 in.) Net weight: approx. 18.55 kg (39 lb)
Baseboard size: 90 x 110 cm (35 x 43 in.) Filters: Dichroic, up to 130 densitometric values Usable vacuum table area: 60 x 70 cm (24 x 28 in.) Supplementary filters: approx. 70 Y and 30 M, 18 x 18 cm Supply voltage: 220/240V, 5060Hz Density diaphragm: 0 to 60 (= 2 f-stops) Power consumption: approx. 500W Size: approx. 65 x 44 x 71 cm (25.6 x 17.3 x 28 in.) Max. loading of power supply unit: approx. 1500W Net weight: approx. 33 kg (72 lb) Net weight (standard outfit): approx. 130 kg (286 lb)
Request a hard copy
contact@colex.com about Colex Colex Home Page
1998 Colex Imaging Inc. All rights reserved. 347 Evelyn Street,
http://www.colex.com/durstlab18.html (5 of 6) [8/8/2001 1:48:32 PM]
Paramus, NJ 07652, USA Tel: 201-265-5670, Fax: 201-265-7093
http://www.colex.com/durstlab18.html (6 of 6) [8/8/2001 1:48:32 PM]
Tags
Fisher 400 XM-3546 Smartfinder 5014046 DGX-500 300 Deskjet 6127 1600 IU KX-F130 Kodak C713 VPL-CX80 VG-88 ER-2403 HT-DB750 DCR-TRV8 LAC-M8400R DVD-SH854 CDE-102RI Motorola V360 Shaker Dmrex769 Kardon 330A PE319 DSC-S780 Extensa 5610 YDP-151-323 Nexus ONE Strd2020 C12AWR-ne2 Island Gpsmap 2006 Gpsmap 62S C T SGH-T739 FWD-S47h1 Monitor HD300LD-KIT D 4 96888 A7vivm Digital Plus NMC 2001 Coolpix S600 KD-DV5302 RC-1070 GO 950 Radeon 9600 Nokia 1616 AKE 30 UX-BD80 Bd90 CDX-GT50UI 151936 FA624vario FR-2B 9800XL VLT2081 EWF887 EP725 MX800 Kx-tga101 DV364 Review LV-7220 KDC-7021 PCG-SRX41P PCV-V1-G 5552 BL Live 6 DMC-FX30 Germany Tricolore BX305FW LF-D7150D Sixty 7 03 YZF-R6R Digimax A55W The Dead Mc Bladesystem Music Ixus 130 RL62vcts UX-F34CW FTA Plus M-identity Dwl-G700AP Logitech S100 HTS3154 12 CP-S220W HTS8150 Morphous-2006 Doro 541 Ideapad U110 DC-J221 Laserfax 3245 RS21ddsv N10T ONE Resurrection -w APA1100 Maxxum 5000
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101







