Esprit 728 Plus
|
|
Bookmark Esprit 728 Plus |
About Esprit 728 PlusHere you can find all about Esprit 728 Plus like manual and other informations. For example: review.
Esprit 728 Plus manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Esprit 728 Plus please write about it to help other people. [ Report abuse or wrong photo | Share your Esprit 728 Plus photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Esprit 728 Plus, size: 1.1 MB |
Related manuals Esprit 728 Plus Installation Manual Version 3.3 |
Esprit 728 Plus
User reviews and opinions
| rand() |
2:18am on Monday, October 11th, 2010 ![]() |
| I have nothing to say, mac for me is over rated always ends up in the trash quickly only spend my money. Screen is great. I use this iMac for all of my work. I work with Adobe CS5 for special effects, photography. | |
| MarkColeman |
11:58am on Wednesday, September 8th, 2010 ![]() |
| i use this product to send xbox 360 game video directly to imac 27inch great value when i bought it here at JR world. You can zoom in and out using the mouse, super easy to assemble, all around awesome product. Easy To Set Up | |
| RLeslie |
12:52am on Thursday, July 8th, 2010 ![]() |
| Once again Apple has created a cute looking product that works good. But it does not live up to the hype. Great product at a good price,[...] I saved almost $300 as compared to buying at a local Apple store. ($50 discount from list. | |
| James Clark |
2:17pm on Monday, July 5th, 2010 ![]() |
| I am in love. I can honestly say I have been waiting for this computer all my life. This is the sixth Mac product we have purchased and are very satisfied with the computers, and with the MacConnection service. | |
| davidkpt |
5:47pm on Wednesday, April 14th, 2010 ![]() |
| I chose the iMAC21. I absolutely love it! Very easy to use. My mom who is very computer illitereate can also use it with ease! build quality, design, Easy to Use/Setup. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

MODEL 633 KEYPAD
X O D R
E C U R I T Y S Y S T
ESPRIT
User Manual
TROUBLE DISPLAY
Light "ON" =
[1] [2] [3] [4] [5] [6]
NOTE: Use key [8] to chime program keypad zone.
No battery/Low battery [7] Communicator fail to report [8] Time lost * Power failure [9] Tamper or zone wiring fail AC fail [10] Telephone line monitor No bell [11] Fire trouble [11] Fire trouble Bell output limit Aux. power output
Programmable "chime" zones. Pressing any of these keys for 3 seconds activates chime zones (intermittent beeps) or de-activates chime zones (continuous beeps).
For regular arming the green LED must be "ON" (all zones closed) before system can be armed. Flashing indicates that exit delay is in progress.
* To program or change the time Press: [ENTER] + master code +
[MEM] + 00-23 for hours + 00-59 for minutes + [ENTER] + [CLEAR].
Zone lights
Red LED illuminates when system is armed.
When "ON", indicates existence of trouble conditions. Press to view the "trouble code" display.
Press for 3 sec. to enable keypad buzzer "mute" (intermittent beep) or disable it (continuous beep).
+ CODE (NO PARTITION)
Y ED AD RM A
MEM MEM
When "ON", indicates if alarms were generated while system was armed. Press [MEM] to bring up alarm zones stored in memory.
Software versions prior to 2.00: "AWAY" auto bypass arming. Versions 2.00 and beyond: "AWAY" force arming. (See p. 11)
+ CODE (WITH PARTITION)
System "B" arm/disarm key + Display
+ CODE
Activates manual zone bypassing. You select which zones to leave open when arming the system.
Activates "STAY" arming. To stay on the premises,and still be protected, "STAY" (partial system) arming permits movement in pre-selected, unarmed zones.
+ CODE (PARTITIONED SYSTEMS)
** Enabled by alarm system installer
ENTER ENTER System "A" arm/disarm key + Display 10 ** Oops! Made a "FAST ARM" key. Press for 2 seconds mistake? Just press Use this key to STAY and system arms automatically. [CLEAR]. It erases any store keypad 11 ** entries in memory. No need to enter an access code. keypad entries and "FAST STAY ARM" key. Press for 2 seconds and returns control panel the system "stay" arms automatically.No need to to previous status. enter an access code.
Paradox Security Systems - Graphic Dept. - PRINTED IN CANADA
UM633 970213-0002
ESPRIT BURGLAR ALARM CONTROL PANEL Welcome to the world of ESPRIT technology. Your Esprit control panel has been designed with ease of use and simplicity in mind. Weve developed an advanced technology control panel with powerful features that ANYONE can use, without memorizing complex, confusing codes or taking a course in computer programming!! Not only is ESPRIT easy to operate, with many functions accessible by one touch of the keypad, but its also functional and stylish. We hope that youve already been impressed by its compact design and attractively styled keypads, with their adjustable illumination levels. The dwelling or building that you want to secure can be divided into as many as 24 zones (depending upon which model of the ESPRIT panel you require), and controlled by up to 5 keypads or PS1 bedside remote arming modules. Thanks to the ESPRIT's "partitioning" feature, two distinct systems (A and B), a dual area (assigned to both systems) and a common area (no system assignment) can be created and controlled by the panel. Partitioning can be used in installations where shared security systems are more practical, such as office/warehouse buildings, or apartment/condominium complexes. The ESPRIT 633 keypads comprehensive 12-LED zone display, 8 function keys and keypad sounder serve to keep you instantly aware of alarm, system and operational status. Motion detectors, smoke, glass break, as well as vibration/shock and door/window contact sensors will all report to ESPRITs RISC microprocessor brain, and vital security information will be communicated to you by the keypad display.
Control panel software versions 2.00 and beyond
The ESPRIT can report a wide range of status conditions to the central monitoring station. Automatic test reports can also be sent to the central to ensure that your system is functioning properly. We recommend that such tests be conducted regularly. Please consult your installer for instructions. Using telephone lines, a computer modem & high-security software, your installation or monitoring company can perform remote diagnostics and modifications to your ESPRIT panel at your request. In addition, your panel can also be remotely armed should you forget to arm it. Depending upon the panel, you may even obtain an activity printout of the last 120 events that occurred in your system. All panels software version 3.00 and beyond, will provide a report of the last 256 events. This reduces time and expense devoted to security supervision and can be performed in minutes. Look Everything you need to know about your system is clearly and simply displayed on the Esprit keypad. The keypad diagram on the back page of this manual provides you with an excellent introduction to the roles of the keypad function keys. Individual zone LIGHTS communicate the status of the zones in your system. If the zone LIGHT is not on, the status in that zone is normal. If the zone LIGHT is "on" (constant light), this means the zone is open. If the zone LIGHT is flashing, this means that there is a zone wiring problem (which will be automatically communicated to your security company.) Note: If [2ND] key is on, it indicates that a zone from 13-24 is open or has a wiring problem. Press the [2ND] key. It will flash, and the light(s) corresponding to the affected zone(s) will illuminate. Listen Every time a key is pressed, the keypad beeps (0.5 second tone) to show that the entry has been recognized. When you enter
information on the keypad, it will guide you with beep tones that communicate acceptance or rejection of your entries. You should be familiar with these two keypad beep tones: Keypad beep tones CONFIRMATION beep: When an operation (i.e. arming/disarming) is successfully entered on the keypad, or when the system switches to a new status/mode, the sounder produces an intermittent beep tone. END/REJECTION beep: When the system reverts to previous status, or when an operation is incorrectly entered on the keypad, the sounder emits a continuous beep tone. "PARTITIONING" (available on 737, 728, 738, 748, 748ES models) Based on your instructions, your installer can program your panel to recognize and control two separate systems by activating the panel's "partitioning" feature. When partitioning is activated, each zone can be defined as belonging to System A, System B, both systems (dual area) or given no system assignment (common area). User access codes can also be programmed to arm/disarm one system or both systems simultaneously. Your keypad can display the status of both systems. In partitioning mode, when System A is armed, flashes*. If System B is armed, the light flashes*. When both systems are armed, both of these lights will flash*. *On control panel models 728, 728 EXPRESS and 738 EXPRESS using software versions 2.1X onward, lights indicated will not flash, but will be constantly illuminated.
Code priority When deciding who should have access to your security system control panel, please keep in mind that each of the Esprit master and user codes can be assigned a different code priority. Code priority determines the level of security access each user will have, and which features and functions they can activate. The Master User Code (00) and User Code 01 can program user codes. User Codes 01-16, or 01-48 (on control panels software version 3.00 and beyond) can be programmed to arm/disarm the system, activate [STAY] or [AWAY] arming, and zone bypassing. These codes can also be designated to arm/disarm only System A zones, only System B zones, or both systems by your installer. Programming User Codes In addition to the master code, your Esprit control panel can be programmed to accept up to 8, 16 or 48 user codes, depending on the control panel. You can choose to use either 4 or 6-digit access codes with your system. 6-digit codes are considered more difficult to crack and are therefore seen as more secure. If, however, ease of recall is your priority, then 4-digit access codes can be programmed instead. Once your codes are entered your panel will store them even after total AC and battery failure. Note: Never select a code that is too simple or too obvious, such as your telephone number or street address or codes such as 1234, since these codes are used as defaults by many manufacturers. Your installer will program the Esprit to accept 4 or 6 digit codes, and also assigns code definitions to all access codes. To create or modify access codes, follow the steps indicated below. The master code must be used to enter programming mode to program user codes. Each access code is made up of 4 or 6 digits.
(determined by alarm installer.) The master code 474747 and user codes are identified by a 2 digit "code number": ACCESS CODE Master User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12 User 13 User 14 User 15 User 16 User 17 User 18 User 19 User 20 User 21 User 22 User 23 User 24 CODE # 24 ACCESS CODE User 25 User 26 User 27 User 28 User 29 User 30 User 31 User 32 User 33 User 34 User 35 User 36 User 37 User 38 User 39 User 40 User 41 User 42 User 43 User 44 User 45 User 46 User 47 User 48 CODE # 47 48
zones are armed. You may choose to have entry/exit points like doors or windows protected, or the basement, or perhaps all the zones on the perimeter of your home or establishment. Based on your instructions, your installer programs the control panel to arm certain zones in stay arming mode. These programmed stay zones will arm on "stay" mode and can only be changed by your installer. Please remember that fire zones cannot be bypassed. (Using this convenient feature, you can "stay" arm the system and then leave the premises while others remain in the protected area.) Pressing [STAY] + ACCESS CODE (or KEY [STAY/11] - see one key arming) on the keypad activates the stay arming command. STAY arming can also be activated by a key switch - please refer to key switch/push button arming. (3) ONE KEY arming (One touch system arming - no code required) KEY [10] regular arming When the "READY" light is on, pressing KEY [10] steadily for 2 seconds automatically "full" arms the system, if programmed. No user code is required. This feature can be used to allow specific individuals like service personnel (i.e. cleaners, maintenance) to arm the system when leaving the protected area, without giving them access to any other control panel operations. KEY [STAY/11] stay arming Please refer to stay arming section above for a full explanation of this feature. There is no need to wait for the "READY" light before stay arming, however all zones that are defined to be armed in "stay" mode by your installer must be "closed" (no movement in
the zones when arming the system). Pressing key [STAY/11] steadily for 2 seconds will automatically "stay" arm the system. When the system is "stay" armed, pressing key [stay/11] will activate an exit delay, and then return the system to STAY ARM status. Pushing key [10] will activate exit delay and "full" arm the system. Double Stay arming During the exit delay, press [STAY/11] again to switch any delay 1 or delay 2 zones to instant zones. 24 hour Stay zones, follow Stay zones and instant Stay zones are not affected. Full system arming cancels Double Stay arming. Fast Exit Exit while system is armed in Stay mode (the light flashes*): A. Fast exit and stay key [11] To exit the premises and remain Stay armed, press key [STAY/11] for two seconds. The system will switch to exit delay mode ("READY" LED flashes). At the end of the exit delay period, the system will return to Stay arming mode. B. Fast exit and regular arm key [10] Press key [10] for two seconds. The system will switch to regular arming (the and lights flash*) with an exit delay (READY LED flashes). At the end of the exit delay period, the system is regular armed. *On control panel models 728, 728 EXPRESS and 738 EXPRESS using software version 2.1X, keys indicated will not flash, but will be constantly illuminated. Software versions 2.2X onward, keys indicated do not illuminate. However, if system is Stay armed, [STAY] will illuminate.
Key switch/Push-button Arming Your system can include a key switch or a push button that arms/disarms the system. This arming method is particularly useful when installed in a master bedroom, making system arming and disarming convenient and accessible. The beautifully styled Esprit PS1 bedside remote has been specifically designed for this application and includes a panic zone. If an alarm is generated in your system, or if the system is in entry delay, the system can only be disarmed from a keypad (if keyswitch is defined as "stay" arming), using an access code. Please ask your installer for more information. (4) MANUAL BYPASS arming [BYP] plus ACCESS CODE (Arms the system while bypassing defective zones and/or zones you wish to leave open) Note: When you bypass a zone, it is no longer monitored by the security system. It will not generate an alarm on the control panel. You might not wish to arm the entire system when, for example, workers are renovating part of your house, or for any other reason you need to leave a zone open. If a component of your security system is damaged, it can also be bypassed until repairs are made. Manual bypass arming instructs the control panel to ignore zones that you designate open, so that the rest of the system can still be armed. (Based on your instructions, only zones that your installer has programmed bypass-enabled can be bypassed during manual bypass arming, auto-bypass (Away) arming or Stay arming. Please note that the fire zone can not be bypassed.)
Press the bypass [BYP] key, followed by your ACCESS CODE. You are now in bypass mode. The [BYP] key will be illuminated and if zones are currently bypassed their lights will come on as well. Enter the key numbers corresponding to the zones you wish to "bypass". Press again on the key if you wish to undo a zone selection. If you have entered the correct zone bypass information, press [ENTER]. The [BYP] key light will remain on indicating that zones have been bypassed. If you make an error entering zone numbers, press [CLEAR]. By using the bypass recall feature, you can reinstate the latest zone bypass instructions saved in memory. Press [BYP] while in manual bypass arming mode and the previous bypass status will be reestablished. This eliminates the need to enter the same "bypass" information every time you arm. (5) AUTO BYPASS (away) arming [AWAY] plus ACCESS CODE Control panel software version prior to 2.00 (System arming without entering zone bypasses - If programmed) If you want to arm the system without manually entering zones to be bypassed on the keypad, you can use the Away auto-bypass feature. [AWAY] + ACCESS CODE should be keyed in. The panel will automatically bypass any open zones after the exit delay terminates and the system will be armed. The ready light does not have to be on, but all open zones must be bypass-enabled. If any zones have been left open, the [BYP] key light will illuminate to indicate that zones have automatically been bypassed. (The fire zone cannot be bypassed.) FORCE (Away) arming [AWAY] plus code Control panel software versions 2.00 and beyond: To arm the system rapidly without waiting for the READY light, use
Control panel software versions prior to 2.00
Force Away arming. Press [AWAY], followed by a valid access code. Once the exit delay expires, any open zones will not be considered activated by the panel. Open zones will not be protected, and will not generate an alarm or prevent arming. These Away zones will be activated (and, therefore, protected) as soon as they are closed. Armed status is indicated by the light flashing*. (The fire zone cannot be force armed.) *On control panel models 728, 728 EXPRESS and 738 EXPRESS using software version 2.1X, key indicated will not flash, but will be constantly illuminated. Software versions 2.2X onward, key indicated does not illuminate. Notes: 1 - These features are not recommended for regular use because leaving zones open can reduce the efficiency of system protection. (Auto-bypass Away arming and force arming are ideal features for use with overhead garage doors!) 2 - Upon system disarm, bypassed zones are cleared, unless they have 24 hr. definition. "No movement" supervision feature Your panel can be programmed to send a report and/or arm the system if the system is not armed (full or stay arming) and there is no zone activity for a preprogrammed amount of time. This is a particularly useful feature when supervising the elderly, individuals with chronic health problems or an individual that lives alone. Automatic Arm on Time Your installer can program your system to arm at a specific time
each day. In this mode, all protected zones and detection devices must be in "normal" status before arming can occur. Panic zones If you need to signal a panic situation, the Esprit provides three "panic" zones on your keypad. These panic zones must be programmed by your installer. Pressing keys [1] and [3] simultaneously for 2 seconds will generate a panic alarm. Pressing keys [4] and [6] simultaneously for 2 seconds will generate a panic alarm or, if programmed, a "medical alarm". Pressing keys [7] and [9] simultaneously for 2 seconds will generate a "panic" alarm or, if programmed, a "fire alarm". Based on your needs, your installer can program these panic zones to generate audible alarms (sirens or bells) or silent alarms, both of which can also be sent directly to your central security station. The 3 different panic zones can also communicate specific messages to your monitoring station, i.e. pressing panic means "call the police", pressing panic means "call the fire department" etc. Ask your installer for the exact definition of your panel's panic alarms. DISARMING THE SYSTEM (without partitioning) Enter the area using the designated entry-exit door(s). The keypad sounder emits a constant tone to remind you to disarm your system. Enter your user code on the keypad before the entry time expires. If you make a mistake while entering this code, press [CLEAR] and re-enter it. The "armed" light will go off and the sounder will stop. If a fire or 24 hour zone alarm was generated while the system was armed, entering your user code will silence the siren. However, you should then check the zone and eliminate the cause of the alarm. 24 hour zones that restore and re-alarm will cause another alarm 30
seconds after an access code is entered to silence the alarm. If you are unable to pinpoint the reason for the alarm, call your installer. SYSTEM ARMING/DISARMING (with partitioning) Zones can be divided into two systems. Based on your requirements, the installer designates which zones belong to "System A" or "System B" both systems (dual area) or are not given a system assignment (common area). (Zones can also be selected to arm when both systems are armed - these zones will only be armed/disarmed upon full disarming.) Once zones have been assigned to either "System A" or "System B", code definition, also programmed by the installer, determines which access codes can arm "System A" zones, as well as which codes can arm "System B" zones. Codes can also be given access to both systems. When the "READY" light is on, entering a code that can access both systems will arm both System A and System B. The and lights will flash*, indicating the panel's armed status. Entering this code when the panel is armed will disarm both systems. To arm/disarm each system separately, do the following: Press [STAY] + a valid access code to arm/disarm "System A". (Valid access code = "System A" code, or code with access to both systems.) When the light flashes*, this indicates System A's armed status. Press [AWAY] + a valid access code to arm/disarm "System B". (Valid access code = "System B" code, or code with access to both systems.) When the light flashes*, this indicates System B's armed status.
*On control panel models 728, 728 EXPRESS and 738 EXPRESS using software versions 2.1X onward, keys indicated will not flash, but will be constantly illuminated. Note: "System A" codes can stop sirens coming from "System B" zones (and vice versa), but will not disarm a system that is in alarm. Pressing key [10] activates "one key" full arming. (When partitioning is enabled, System "A" and "B" are armed when key [10] is pressed.) Pressing key [STAY/11] activates "one key" stay arming. (When partitioning is enabled, System "A" is armed by pressing key [STAY/11].) PS1 Bedside remote module Pressing any one of the three keys of this module will arm or disarm the system if in "stay" mode (when partitioning is not activated). Please note that if the system is in entry delay or if an alarm is in progress, for your protection the panel can only be disarmed from a keypad. Pressing any two PS1 keys simultaneously will generate a panic alarm. Your installer can also adjust the PS1's illumination level and mute the buzzer as required. Alarm Memory [MEM] The memory key [MEM] on your keypad will illuminate if any alarm situations take place while your system is armed. A record of all alarm situations that occur is stored in memory. After disarming the system, pressing once on [MEM] brings up the zones that were open during the last alarm period. Programmable output Not only does your Esprit panel provide top security, it also offers you total convenience. Your installer can program the panel to
reset smoke detectors & Glasstreks, to activate strobe lights, to activate light switches in your home or office, to reduce or increase building temperature, turn on/off air conditioning, open/close automatic garage doors, and more. Talk to your installer about this helpful feature! Keypad night illumination The installer can adjust the illumination to the level you require. Chime zones Zones 1 to 6, as well as the local keypad zones, can be programmed as chime zones. A chime zone "advises" you when it is opened by creating a rapid intermittent beep tone. To turn on the "chime zone" feature, press on the selected zone key for three seconds until the intermittent chime beep is heard. This means that the chime feature has been activated. If a continuous beep is heard, this means that the chime is "off". (Keypad zone chime is enabled by pressing key [8].) If you have more than one keypad in your system, please "chime" program each keypad separately. Keypad chimes must be reprogrammed if the panel suffers a total power loss.
CHIME KEYS:
TROUBLE DISPLAY [TRBL] and TROUBLE MEMORY [2ND] 11 different trouble conditions can be displayed on the keypad. When trouble conditions occur, the [TRBL] key illuminates and if programmed by your installer, keypad sounder will beep. (When power supply failure trouble occurs, the [TRBL] key flashes rapidly.) Display will alternate between SYSTEM TROUBLE/POWER SUPPLY and the system status message. Press on this key and it flashes, indicating that your panel is in "trouble display" mode. Control panel software versions prior to 2.00: Key lights that illuminate in "trouble display" mode tell you which trouble conditions are taking place and/or are in memory. Press on any key except [2ND] to return the keypad to normal zone display. Trouble conditions will remain in "trouble" memory. Pressing the [2ND] key displays current trouble conditions. Pressing [CLEAR] will erase trouble conditions in memory. Control panel software versions 2.00 and beyond: The keys that illuminate in trouble display mode tell you which trouble conditions are currently taking place. Pressing on any key will return the keypad to normal zone display. Light No battery/low battery If the battery is not connected to the control panel, or if it is at low capacity, this is indicated by the illumination of light [1]. When trouble indicator [1] illuminates, this means that the battery connected to the panel should be replaced because it can no longer provide adequate back-up current in the event of a power failure. Trouble indicator [1] will also illuminate if the battery voltage drops to 10.5 volts while the control panel is running on battery power (with no AC).
Key [1]-[6] Turns chime "ON" or "OFF" in zones numbered 1-6 Turns the chime "ON" and "OFF" for the zone connected to this keypad. Each keypad must be programmed independently. Turns keypad sounder "ON" and "OFF" (intermittent beep means MUTE is activated, keypad sounder "OFF", depress for 2 seconds to disable)
Key [8]
PANEL BUZZER MUTE:
Key [9]
Light Power failure (software versions 1.4 and beyond) If AC power is not being supplied to the control panel and/or the power supply is unable to charge the battery and/or the power supply voltage exceeds 14.9 volts, light [2] will illuminate. Power failure can be excluded from key [TRBL] display by your alarm installer. Light AC power failure (software versions prior to 1.4) If AC power is not being supplied to the control panel, light [3] will illuminate. AC trouble can be excluded from keypad "trouble display" by your alarm installer. Light Bell disconnect If a bell or siren is not connected to the bell/siren output, this is indicated by the illumination of light [4] in trouble display mode. Light Maximum bell current If light [5] illuminates, it indicates that the processor has recognized that the bell/siren output current exceeds 3A. This causes automatic shutdown of the bell output. Once the problem is corrected, power will automatically be restored to the bell/siren circuit. Light Maximum auxiliary current Light [6] illumination indicates that the processor has recognized that the auxiliary output current exceeds 1A. (748ES -3A) This causes automatic shutdown of the auxiliary output. Once the problem is corrected, power will automatically be restored to the auxiliary output. This output powers such devices as motion detectors and accessory modules. Light Communicator report failure If your control panel cannot communicate with the central monitoring station, light [7] illuminates.
Light Timer loss If the system timer is not functioning, usually after a total battery and AC power failure, light [8] illuminates. The timer should be reprogrammed after total power loss. To reprogram the timer (control panel software versions prior to 2.00): Press [ENTER], master code/user code 1, and [MEM], followed by [ENTER]. Then enter 2 digits (00 to 23) for hours, followed by 2 digits (00 to 59) for minutes. Press [ENTER] twice. If trouble light [8] is still illuminated, press [TRBL], then [CLEAR] after programming the time. To reprogram the timer (control panel software versions 2.00 and beyond): Press [ENTER], followed by the master code/user code 1, and [MEM]. Key [MEM] flashes. Then enter 2 digits (00 to 23) for hours, followed by 2 digits (00 to 59) for minutes. Press [ENTER]. Light Tamper/zone wiring failure Light [9], if illuminated, means that there is a wiring problem in one of your protected zones. Light Telephone line monitor Light [10] illuminates if the panel detects the loss of the telephone line. Light Fire/trouble If the fire zone is cut, the fire zone light and trouble light [11] will illuminate. Most of these "trouble" conditions will be programmed by your installer to be reported directly to your security company. Please make sure to contact your alarm company, however, to ensure that repairs are immediately made to your security system.
Fire Alarm Operation Alarm Upon a Fire Alarm, the bell/siren will operate in "pulse mode". Silence/Reset To silence or reset a fire alarm, enter a valid user code. IMPORTANT: IN CASE OF FIRE, FOLLOW YOUR EVACUATION PLAN IMMEDIATELY! If there is no fire condition, contact your monitoring company without delay to avoid an unnecessary response. Fire Safety in the Home Reasonable fire safety can be achieved by following a three point program: 1. Minimizing fire hazards 2. Providing a fire warning system 3. Having and practicing an escape plan Minimizing Fire Hazards The three traditional fire killers are: 1. Smoking in bed 2. Leaving children home alone 3. Cleaning with flammable liquids such as gasoline Providing a Fire Warning System Household fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome occupants while they sleep. To warn against fire, smoke detectors should be installed outside of each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements.
Having and Practicing an Escape Plan There often may be very little time between detection of a fire and the time that it becomes deadly. This interval may be as little as one or two minutes. Advance warning of a fire may be wasted unless the family has planned in advance for a rapid exit from their residence. Notes: 1. Plan and practice for fire conditions with the focus on rapid exit from the residence. 2. Drills should be held so that all family members know what to do. 3. Each person should plan for the possibility that exit out of the bedroom window may be necessary. An exit out of the residence without requiring the opening of a bedroom door is essential. Provision for the Disabled For special circumstances where life-safety of some occupant(s) depends upon prompt rescue by others, the fire warning system includes a means of prompt, automatic notification to those who are to be depended upon for the rescue. Testing your System It is recommend that your system be tested once a week. Contact your monitoring station BEFORE and AFTER testing. Burglar Alarm Testing With the system disarmed and the READY light on, activate motion detectors (walk in protected area). Open and close protected doors. Observe the zone light. It should come on following each activation If keypad panic keys are enabled (check with your
installer), pushing one of these keys will initiate a local alarm (if programmed) and a signal to be transmitted to the monitoring station (if programmed). Your installer can advise you of the best way to test your particular system. Fire Alarm Testing CAUTION: Do not use open flame or burning materials to test your fire detection devices. Contact your installer for safe methods to test your system. System Maintenance Under normal use, your system requires virtually no maintenance other than regular testing. It is recommended that the standby battery be changed every three years.
IMPORTANT: Keep this information in a secure location. ZONE DESCRIPTION
PARTITIONING ACTIVATED l Yes l No SYSTEM A B 24 Bypass Hr Enabled
Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone Zone
1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24:
l l l l l l l l l l l l l l l l l l l l l l l l
ACCESS CODES Name l 4 digit l 6 digit Code Arming Priority Reg. Stay/A Away/B Byp Master 00 l l l l User 01 l l l l User 02 l l l l User 03 l l l l User 04 l l l l User 05 l l l l User 06 l l l l User 07 l l l l User 08 l l l l User 09 l l l l User 10 l l l l User 11 l l l l User 12 l l l l User 13 l l l l User 14 l l l l User 15 l l l l User 16 l l l l User 17 l l l l User 18 l l l l User 19 l l l l User 20 l l l l User 21 l l l l User 22 l l l l User 23 l l l l User 24 l l l l User 25 l l l l
Code User User User User User User User User User User User User User User User User User User User User User User User 48 Reg. l l l l l l l l l l l l l l l l l l l l l l l
Arming Priority Stay/A Away/B Byp l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l
NOTE: For security reasons, write only the user's name and not his/her access code! When partitioning is not used, zones selected as STAY will be the only ones armed during STAY arming. Consult your installation or monitoring company for any additional information or system modifications.
SPECIAL KEYS AND FUNCTIONS l Key [10] Regular arming is activated. l Key [STAY/11] Stay arming is activated (Arms system A only, when partitioning is enabled) [1] and [3]* Police or [4] and [6]* Auxiliary or [7] and [9]* Fire or l Silent l Audible l Not Used l Silent l Audible l Not Used l Silent l Audible l Not Used
IMPORTANT This security system should undergo frequent testing. However, despite regular testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. WARRANTY Warranty conditions for the Esprit may vary from country to country. Please consult your local dealer for complete warranty information. In all cases, the warranty does not cover malfunctions arising from installer error or failure to follow installation/operation instructions, nor does it apply to damages due to causes beyond the control of Paradox Security Systems, such as lightning, excessive voltage, mechanical shock or water damage. LIABILITY Under no circumstances shall Paradox Security Systems be held liable for any direct or indirect damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation, operation or failure of this product.
* Both keys must be depressed at the same time for 2 seconds Armed LED will flash. The PGM (Programmable Output) function (if applicable), is ___________________and is activated by SYSTEM TIMES Entering and exiting your premises is permitted through doors that you and your installer have determined. You have one exit time and up to two individual entry times i.e. Zone 1-Front door delay 1 (30 sec), Zone 7-Garage door delay 2 (90 sec) You have seconds to EXIT your premises. Your Entry delay 1 is sec. and you may enter thru zone #. Your Entry delay 2 is sec. and you may enter thru zone #. Your Siren, if activated by an alarm, will sound for minutes. OTHER INFORMATION This alarm system was installed on: By: Service is provided by Tel: Your monitoring station's phone number is: Your account number is: Your alarm transformer location is and is on circuit #
UL verified compatibility of the 633 with Esprit models 708, 728, 728 EXPRESS, 738, 738 ESPRESS, 748, 748ES and SRI-18. Look for and marks on products. Only products bearing those marks are UL and ULC listed.
Tags
YFZ450-2007 GT-C5130 125-1997 PA-3100 SMC2635W KDL-40EX501 PT-8000 Vietcong MF110 Mcintosh C42 DGL-4100 Review EB-1725 Montreal CD34 Lexmark E238 Fishmark 500C Nikon WT-2 MDE9651 Easyshare P880 Samsung ST45 XP-V70 CR-FOX 8818 PC Minolta 7075 Roland E-60 KD-LX10R HD7810-85 Videostudio 7 DR4810 10 0 Satellite L40 773 TFT Al II GZ-HD300 Abit KG7 CF-340 Quickwash Deskpro 386 XR-CA630X JX25 Jx35 RX585 Ixus V3 LA40B610 Lide 90 160 HD Fishfinders CDX-3103 P-2302hwudl-P1 Curve 8320 CDX-GT620U RE-32FZ10PX Urc 6131 KM500C SC-HT1500setupguide 20LC1RB GT-I7500 CQ-C1303U 105S59 1E-08 KZ-32TS1E FWD-S47h1 PSS-140 A8 W12 Ifinder Hunt ATS-404 Temporis 10 Roland TD-7 Analog 25PT4403 KX-TG7321RU Instruments Phep Laser Powerlite S5 VX2000 EX-V8 BDV-IZ1000W Pinkie PIE W3706MC 7 GO 1220S Lide 30 Touch 530 D3250 DEX-P99R Motorola U9 WD-14126RD IC-751A PX-mxxxl S10 2000 Logicom G350 MC-CG463 Tepee KX-TG1311FX ESF6124 WHR-G300N PV-GS19 CQ-DF403W LUX1R Titan V2 PRO 8 EX-8000
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101





