Documents
FURUNO DEEPSEA WORLD
ELECTRONIC CHART DISPLAY AND INFORMATION SYSTEM (ECDIS)
Model FEA-2105
q Supports safer and more efficient navigation at sea q Complying with IMO Resolution A.817(19), IEC 61174, and related IHO standards q Continuous monitoring of the ship position through multi-sensor Kalman filter processing using GPS, DGPS, SDME (through the water or ground tracking Doppler), gyrocompass and radars (echo reference) q ENC operation with IHO S-57v.3 vector and ARCS raster chart systems q Route Planning and Route Monitoring q Grounding warnings, safe depth contours q Superimposing radar images on the electronics charts (option) q Target vectors and data from ARPA/radar to aid collision avoidance
The FEA-2105 ECDIS is a result of FURUNO's vast experience in the development and use of advanced computer techniques providing the highest quality marine electronics. The FEA-2105 complies with IMO Resolutions, IHO, IEC standards and satisfies the mariners stringent demands for a safe, but efficient aid to navigation. Useable charts are derived from an official ENC Database. The resultant SENC may be edited by the operator. When ENC coverage is not available, an ARCS chart may be used. Instant selection is assured as both chart databases are stored in the ECDIS memory.
simplified by using advanced ergonomic operating techniques and easy to use menus. Extremely accurate position, depth, alarm data and other warning facilities assure the vessel of reliable route monitoring. Using the FEA-2105 contributes greatly to safer vessel navigation and efficiency as well as reduced operator workload when compared to using traditional paper charts. The ECDIS primarily displays electronic charts, navigation lines, ARPA data, user defined information and offers vessel route planning and monitoring. ARPA and radar images may be overlaid on the ENC display.
The desired chart database is loaded and updated using The FEA-2105 has superb display resolution, using a a CD-ROM. Radar image and chart matching is easily 21" multi-color monitor (1280 x 1024 pixels). A vividly accomplished. The standard display is a tabletop mount clear picture, graphics, text and data is provided for a version with an optional deck mount pedestal being relatively inexpensive investment. Route planning is available.
Catalogue No. L-159a
The future today with FURUNO's electronics technology.
FURUNO ELECTRIC CO., LTD.
9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65-2111 Telefax: +81 (0)798 65-4200, 66-4622, 66-4623
TRADE MARK REGISTERED MARCA REGISTRADA
SPECIFICATIONS OF FEA-2105
1. Standards IMO Resolution A.817(19), IEC 61174, IEC 60945 EMC/ Environment/General requirements 21-inch high-resolution color CRT (1280 x 1024 pixels)
634 25.0" 573 22.6"
Display Unit
502 19.8" 753 29.7"
Monitor
2. Display Tube
Processor Unit
3. Media 4. Useable charts Windows NT IHO/S-57 v.3 vector chart ARCS raster chart C-MAP vector chart (option) 5. Presentation Modes True Motion North-up, Relative Motion North-up 6. Display of data Own ship: Position, SMG, CMG, heading Route: Planned route, Monitored route ARPA targets: Range, bearing, speed, course, CPA and TCPA Others: EBL, VRM, parallel index line, cursor position, navigation and pilot data notebook 7. Interface (IEC61162-1) Gyrocompass: 1 analog or 1 serial SDME (Speed log): Single-pulse type or serial EPFS: Up to 2 serial inputs 5 max. with A-Adapter Water depth: Serial input Wind sensor: Dual axis-serial input ARPA/Radar: Serial
588 23.2"
6- 2.0" 150 5.9" 150 5.9" 10 0.4" 440 17.3" 470 18.5" 179 7.1"
35 22.602N 20.22.602N 135 22.602N 20.5 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.22.602N 20.5
Connection Diagram
35 22.602N 20.22.602N 20.22.602N 20.5
Gyro (Syncro/Stepper) Log (200 p/nm) Outside Channel Limit Alarm WP Approach Alarm 24 VDC Gyro Single or Dual Axis Log EPFS 1 EPFS 2 Radar/ARPA 1 Radar/ARPA 2 Wind Sensor Echo Sounder 24 VDC Radar Signal Gyro
B-ADAPTER (built in the pedestal)
Planning Station or 2nd ECDIS Processor Unit Printer
A-ADAPTER (built in the pedestal)
Optional Shipyard Supply
24 VDC
115/230VAC for monitor
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
FURUNO U.S.A., INC.
Camas, Washington, U.S.A. Phone: +1 360-834-9300 Telefax: +1 360-834-9400
FURUNO DANMARK AS
Hvidovre, Denmark Phone: +00 Telefax: +01
00063T Printed in Japan
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K. Phone: +44 2392-230303 Telefax: +44 2392-230101
FURUNO NORGE A/S
lesund, Norway Phone: +102950 Telefax: +127021
FURUNO FRANCE S.A.
Bordeaux-Mrignac, France Phone: +Telefax: +48 01
FURUNO SVERIGE AB
Vstra Frlunda, Sweden Phone: +46 31-7098940 Telefax: +46 31-497093
FURUNO ESPANA S.A.
Madrid, Spain Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97
FURUNO SUOMI OY
Helsinki, Finland Phone: +Telefax: +3417 5716
486 19.0" 395 15.6"

AP6.1 Connection Appendix 6) Connection to FEA-2105
AP6.1 Connection
To connect FA-100 to FEA-2105; 1. Install high speed SIF card to the corresponding port in FEA-2105 A-adapter. The card is identified by the label IEC 61162 from other cards.
TS2 TS1 TIF1 port
TIF4 port
High speed SIF card (Carrying IEC61162-2 label)
TS-x (Connect FA-100 to one of TS terminals.)
TS8 TS7
TIF7 port
Fig. AP6.1.1 FEA-2105 A-adapter
a) High speed SIF card (Carrying IEC61162-2 label)
b) RIF module (RX only)
c) Normal SIF card
Fig. AP6.1.2 I/F cards for A-adapter
2. Connect CB-100 of FA-100 to A adapter of FA-100 as shown in Fig.AP6.1.3. The AIS port, L/R ECDIS/RADAR, EXTRA I/O or PC I/O is used on FA-100.
Port L/R or ECDIS/ RADAR EXTRA I/O
Signal TD4-A TD4-B GNG(iso) TD5-A TD5-B GNG(iso) TD8-A TD8-B GNG(iso)
CB-100 (48P type) 39
CB-100 (41P type) 35
FEA-2105 FA-100
CB-100
TDX-A TDX-B GND (iso) IEC-61162-2
Terminal No.
A adapter
TS X RXx + RXx TXx + TXx -
Port - L/R or ECDIS/RADAR - EXTRA I/O - PC I/O
TX GND GND GND
PC I/O
Fig.AP6.1 3
AP6.2 Updating FEA-2105 system program
The FEA-2105 system program which supports AIS function is version 3.01 and above. Program version of FEA-2105 is displayed at the lower right corner.
System version
If the program is lower than version 3.01, follow the procedure below.
Closing ECDIS program 1. Connect the service keyboard to EC-1000 (EC-1000B).
CDROM drive
Service keyboard FDD Service keyboard
2. Press [TAB] while holding [ALT]. The pop-up window as shown in the following picture appears.
3. Press [TAB] while pressing [ALT] until ECA WATCH appears in the list box. ECA WATC window appears.
ECA WATCH
ANTS.ECDIS PROCESS STARTER This window control execution of various ECDIS software computers. To move this window in background click chart area with SELECT push button.
INS PROSESS HUMAN INTERFACE S57/DRAWING VOYAGE RECORDER CONNING DISPLAY ACCESS SERVER
Restart
Restart Restart
Shutdown the ECDIS
4. Move the pointer onto Shutdown the ECDIS in ECA WATCH window and press [SELECT]. The following message appears.
Service engineer: If you want to close this window 1. Move cursor here and press SELECT button. 2. Use service keyboard and press ALT and F4 key together. ECDIS user: If this window remains forever you can use Power Off/On to restart the ECDIS
When system Program is Ver: 3.01 or more, this message appears.
5. Move the pointer onto the sentence, 1. Move cursor here and press SELECT button. and press [SELECT].
6. Press [F4] while pressing [ALT]. The display changes to Windows NT.
Updating ECDIS program (Ver3.01 and above) 7. Insert the program CD-ROM (ver.3.01 and above) to CDROM drive in EC-1000 (EC-1000B). 8. Run Windows NT explorer in PROGRAM holder in START menu.
9. Select E drive (CDROM) to open the file on the CDROM. 10. Move the pointer onto install holder icon and then press [SELECT] twice to open the holder.
Setup.exe
11. Move the pointer onto Setup. exe file icon and then press [SELECT] twice to open the file. The following window appears.
Warning Installation cant shutdown ECDIS sofware automatically Shutdown ECDIS software befor continuing 1. Use shutdown the ECDIS from EACWATCH 2. Use Alt+F4 to close background window with text press ALT and F4 if you want to close the window OK
12. Move the pointer onto OK and press [SELECT]. The System information window appears. Move the pointer onto [NEXT] and press [SELECT]. The Setup Type window appears.
13. Select installation type and then move the pointer onto [NEXT] and press [SELECT]. The Select Optional Components window appears.
Conning Display version 00.0x (untested) Demo ECDIS version 0x.0x ECDIS version 0x.0x (Select, usually)
ECDIS with Conning Display and trackpilot interf. Version 0x.0x ECDIS with Conning Display version 0x.0x
14. Move the pointer onto [NEXT] and press [SELECT]. The User info window appears. 15. Move the pointer onto [NEXT] and press [SELECT].
Re-enter the Password and HASP.pin number as below. - Password: ECDIS - HASP.pin: 2371
16. Following windows appear in order; Share info, SIO386 Settings, Radar overlay settings, Select default color caribration, COM-port settings and Start copying Files. Move the pointer onto [NEXT] in each window and press [SELECT]. The System Cleanup window appears. 17. Remove the tick in S57 Senc files line and press [SELECT]. The program updating starts automatically.
INS Sav files ECAHI Detail files S57 Group files S57 Senc files S57 Catalog files Voyage Log files
Remove the mark.
18. When the window below appears, move the pointer onto [OK] and press [SELECT]. The Setup complete window appears.
19. Select [Yes] and move the pointer onto [Finish] and press [SELECT]. The ECDIS starts automatically.
Yes, I want to restart my computer now No, I will restart my computer later
AP6.3 Setting
AP6.3.1 Setting on FA-100
Press [MENU][6][1][1] and set I/O SPEED to 38.4 k.
Port PC I/O SNSR 1 SNSR 2 SNSR 3 I/O SPEED 38.4 k 4800 Port LR* BCON EXTRA 1 XTRA I/O I/O SPEED 38.4 k 4800 38.4 k 4800
Note: When FEA-2105 is connected to L/R port, I/O FUNCTION of LR port is set to PORT LR: EXT DISP. Keystroke: [MENU][6][1][2]
AP6.3.2 Setting on FEA-2105
1. Insert the KEY disk to the floppy drive. 2. Press INITIAL SETTING twice and INITIAL SETTING window appears.
Set time Parameter Backup Digitizer Backup and Restore Installation Parameter Navigation Parameter Chart Alarm Parameter Optimization Parameter Print Navigation Parameter Print Optimization Parameter Selftest Presentation library Access server and Diagnostic
Fig.3.4
3. Move the cursor onto Installation Parameter and press [SELECT] to open Installation Parameter.
Installation parameters Sensor Parameters
Set parameter default Sensor Channel usage
Workstation parameters Set Signal Workstation Mode Workstations
Cancel
4. Move the pointer onto show SENSOR list.
in Sensor Parameter list box and press [SELECT] to
General Gyro 1 Gyro 2
Speedpilot AIS Transponder VDR
5. Move the cursor onto AIS Transponder and press [SELECT] to show Edit parameters-AIS transponder.
Edit parameters-AIS transponder Connected A- Adapter CH Device interface Device mode
OK Cancel IEC61162-2(38400 bit/s) Allow illegal values Used
IEC61162-1 Transmit checksum Checksum
Char not included (IEC61162-1 or 2)
AP6-10
6. Set items in AIS parameter setting menu as shown in the table below. (Select screened parameters.)
Item Connected A-Adapter Device interface Device mode IEC61162-1 Transmit Checksum Checksum Setting NO YES 1 to 16 IEC61162-2 (38400 bit/s) IEC61162-1 (4800 bit/s) Normal IEC61993-2 Allow illegal values Not used Used $Char not included (IEC61162-1 or2) $Char included (Some old NMEA) Remarks
Set the port number to which AIS is connected.
7. Move the cursor onto [OK] and press [SELECT] to return to Installation parameters window. 8. Move the cursor onto [OK] and press [SELECT] to show SIO Booting. 9. Remove the Key disk from the floppy disk drive.
AP6-11
AP6.3.3 Displaying AIS target
1. Press [CHART DISPLAY] on FEA-2105. The following Chart display window appears. If not, move the pointer onto the Tracking and press [SELECT].
Chart display
Chart Tracking
Past tracks Off Std
Standerd Mariner
Other Route
Other Ship System Ship Primary Ship Secndery
Length 20 min
Labels
ARPA target Length 20 min Labels 5 min
Other Predictor ship 30 User Events Automatic Events Positions sec
Not older than 3 month
Radar Overlay ARPA target AIS targets AIS target names Max. count 200 Max. range 48 nm
Ship true symbol scale
1:50000
2. Set AIS target and AIS target names lines, Max. count and Max. range. AIS target Move the pointer onto Std on AIS target line and press [SELECT] to turn on AIS target display. - Off : AIS target display is off - Std : AIS target display is on - Other: AIS target is on until [STANDARD] is pressed. when [STANDARD] is pressed, AIS target is off. AIS target name Move the pointer onto Std on AIS target names line and press [SELECT] to turn on AIS target name. - Off - Std : AIS target has no ships name. : AIS target has ships name. [STANDARD] is pressed, ships name disappears.
- Other : AIS target has ships name until [STANDARD] is pressed. When
AP6-12
Max. count To set the maximum number of the nearest AIS target from the own ship, move the pointer onto in Max. count box and press [SELECT]. Select 20, 40, 100 or 200 and press [SELECT]. Max. range Move the pointer onto in Max. range box and press [SELECT]. Select 6, 12, 24 or 48 and press [SELECT]. The AIS target within the setting range is displayed on FEA-2105.
AP6-13
AP6.4 Checking AIS signal to FEA-2105
When RX LED in FEA-2105 A-adapter blinks, FEA-2105 receives the signal normally. LED number corresponds to the T.B. number.
C2 TX R8 C1 C8 R1 R3
AP6-14
Tags
W4180N S10 2002 22LU5000 EDC536E Caplio R2 Quad 909 GH20NS10 PS-5105 D 4X4-2006 LVC-CY100NM TB-303 630UA XEA101 Updatecd3 8 510 USB AVH-P3100DVD EOS 30 DEQ2496 G2412HD Krait I6500 JBL L300 Ixus II WD-1409RDA5 Bernina 700D VGN-S560P DX-610 6143 W IP6000D Nuvi 775T Series Usbav-714 PT-LB75U Review X-360 Nokia 3510 DG834GT Bizhub C652 MHC-RG295 2800-500 Husqvarna 235R SR24-4 NWZ-A729 EWF1221 C-500 Zoom EMQ-1 TE100-P1U Array V-AMP 3 Hipath 1120 DTT 4500 TX-SR601 55 S CS300 TH-46PZ81E Minolta XG-A Beverly 500 CS-2194H Dimage A1 Centrifugeuse Kodak C182 KM-1820 UBT780 Sony A700 Fiat Qubo Sport 2004 RHT600R Corso CPX885 STA-2400 Padkontrol 32PW8651 Hts6500-37B DAV-DZ230 AX4spel MM9000 P-class R-872M Roland BX-8 ICF-DS11IP Dumbells WD-6011C CFD-S200 SA-VE505 CT250 LH-T3602SE PM4200 CUV4X-E PCG-R505EL R B ZI2300 2T Studer A700 SP-310 WM2688hnma 3228C WD-1050FHB P1165 HTR-5830 CAL 7T62 900-299011 S75348KG98
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding