Horstmann Electrisaver E30
|
|
Bookmark Horstmann Electrisaver E30 |
About Horstmann Electrisaver E30Here you can find all about Horstmann Electrisaver E30 like manual and other informations. For example: review.
Horstmann Electrisaver E30 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Horstmann Electrisaver E30 please write about it to help other people. [ Report abuse or wrong photo | Share your Horstmann Electrisaver E30 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Horstmann Electrisaver E30, size: 96 KB |
Horstmann Electrisaver E30
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

Electrisaver User and Installation Instructions
The Electrisaver push button boost timer can be used to control immersion elements and other electrical appliances up to 3kW or as an override/extension timer for central heating systems. INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS. WARNING : ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION ENSURE THE UNIT IS PROPERLY EARTHED.
Installation Means of disconnection from the supply having at least 3mm contact separation in both poles must be incorporated in the fixed wiring. We recommend a separate fused circuit from the consumer unit (24 Hour supply) protected by a 15 amp HRC fuse or, preferably a 16 amp MCB. In some cases immersion heater failure can damage the Electrisaver. Installation of a 100 mA RCD will provide additional protection for the unit. If the Electrisaver is to be connected to a ring main then the spur feeding the controller should be protected in the same way. The Electrisaver is NOT suitable for mounting on an unearthed metal surface. Surface Wall Mounting The Electrisaver is suitable for mounting directly on to any surface mounted single gang moulded box having a minimum depth of 28mm. Cable entry being through the most convenient cut-out.
Flush Wall Mounting The Electrisaver can be mounted directly to any standard 35mm deep flush mounting single gang wiring box complying with BS4662
THE ELECTRISAVER SHOULD BE KEPT IN ITS SEALED PACK UNTIL ALL DUST AND DEBRIS HAVE BEEN CLEARED AWAY PRIOR TO MAKING CONNECTIONS.
Connections Use twin and earth cable with a minimum conductor size of 2.5mm2 to connect the Electrisaver to the supply. Use a suitably rated three-core flexible cord (see below) to connect the Electrisaver to the appliance to be switched. For appliances up to 2kW rating use minimum 1.0mm2 conductors. For appliances up to 3kW rating use minimum 1.5mm2 conductors. Heat resistant flexible cord must be used if connecting the Electrisaver to an immersion heater. Connections to the Electrisaver terminal block should be as follows:N in N out L in L out = = = = Neutral in Neutral out to appliance Live in Live out to appliance
out out
SUPPLY SUPPLY APPLIANCE
NEUTRAL LIVE
APPLIANCE
Remove cut-outs before fixing the box. Where appropriate drill the box to provide close fitting entry for cables and heat-resistant flexible cords. Take care to remove sharp edges. All un-insulated earth conductors must be sleeved and connected to the earth terminals on the back of the Electrisaver. The supply Earth conductor and appliance Earth conductor must use the separate terminal connections provided. Clamp all surface wiring to the wall adjacent to the Electrisaver or use trunking where appropriate. The flexible cord to the appliance should be passed through the cable entry hole in the bottom edge of the Electrisaver, and secured under the cable clamp provided. Ensure that the clamp is positioned the right way up ie. the projections on the underside of the clamp should grip the cord in order to secure the cable firmly, the cable clamp screws must be adequately tightened. Carefully offer the Electrisaver to the moulded/metal box and secure using two M3.5 captive screws provided. Do not damage insulation or trap the conductors during this operation. Finally switch on the mains supply, ensure the Electrisaver operates correctly.
Specification Purpose of control: Classification: Contact rating: Power supply: Electronic Timer (Independently mounted) Type 1C Action (RL1) 13(3)A 230V AC Suitable for loads up to 3kW 230V AC 50Hz
Operating temperature range: 0C to 35C Shock protection: Dirt protection: Enclosure protection: Class 1 (Live parts enclosed) Normal situations IP 30
Independently mounted control for surface mounting. Operating time limitation: Case material: Dimensions: Mounting: Boost Period: Timing Accuracy: Intermittent Thermoplastic, flame retardant 87mm x 87mm x 16mm (Flush mounted) 51mm (Surface mounted) Single gang surface moulded box (35mm minimum) Single gang mounting box Model E15 - 15min/30min/60min Model E30 - 1/2 Hour/1 Hour/2Hour +/- 5%
User Instructions
To use the Electrisaver simply press the BOOST button in quick succession until the indicator light for the required boost period is illuminated (see table below).
BOOST PERIOD PRESS BOOST BUTTON TO SELECT LENGTH OF REQUIRED BOOST. Electrisaver E15 Electrisaver E30 Once 15min 30min Twice 30min 1 Hour 3 times 60min 2 Hour 4 times Off Off
To cancel a boost period press the BOOST button continuously until ALL the indicator lights are OFF. Keeping the boost button depressed will cancel any boost period. When the boost is activated the indicator lights will countdown showing the approximate duration of the boost period remaining. Service and Repair The Electrisaver is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please contact a local heating engineer or a qualified electrician.
Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Horstmann Controls Limited, Bristol BS4 1UP 6
Leaflet number P80502 Issue 4

CYPRUS AGENTS SPECIAL OFFER
Horstmann electrisaver E30:
IDEAL FOR: * VACATION PROPERTIES & RENTALS * REAL ESTATE & PROPERTY MANAGEMENT Electronic Boost Control
The Electrisaver is a simple push button electronic timer that saves energy by remembering to switch off when you forget. Pays for itself in lower fuel bills - time and time again! Controls loads up to 3kW - including immersion heaters. Ideal for shops, offices and all around the home! The perfect boiler override or extension timer for central heating systems. Stylish, compact and simple to install. Flush or Surface mounting Applications Include * Immersion Heater Control - especially in Cyprus where most boilers have no emergency thermal cut out. * Air conditioning units - running costs information * Panel Heaters and / or radiators * Towel Rails * Price excludes installation - quotation available on request! Manufactured in the UK by Horstmann (est.1854)
LIMITED OFFER RRP 60
NOW 30
CALL ANDY ON or 693 NOW!
(OFFER CLOSES 31ST MAY 2009)
Tags
TD-W118 UF-590 500 Club LG MG24 DVD-P255K DV-545 EHD60020P Roland MOC1 LP-6100 VP201B Nokia N76 DX660 RR-QR270 10 B FR975-01C 47LB7DF Twain PRO CGC409W BL-C1 SUP 018M Printer 720 32PFL7762D TEO-S125-2000 LE32A430 Lrfd25850SW D-520 Zoom VGN-FS115M BV9600 MP 2550 Poulan 2050 FS-1050 L7500 SD790 IS XC12U CDX-GT08 1202VLZ LH-T552SB LP-7500 MRV-T301 Review GT122D Audiovox UV7 IZ161W 2835W SGH-D830 32PW8505-12 Destinator PN GR-L207 NP-X60 Monster 1100 DC24SC R250S PRO PEG-TH55 TPM M1736N DW-8000 CN-GP50N LN40C650 Diamond 10A TXP50V10E TX-L37d25 29FU1RS RT-28FZ10RX HD2200 Series Sable 1999 XD1170D AA4000 CQ-C1313NE KXF-W6010 TH-50PX600 240V DXZ535 Multi-tool 9000 PRO CT-P8200 MX-200 EX-Z2 AG-SW100 6500S 1100D X39 106 HT-TZ222 Recycler PN58C8000YF Sinus A10 PW1350 MW511 CDX-646 LF652D 3 0 C7660N1 HT-Z210R MS2000R Wizardry 8 6100 Bike RX-V850 Power I DVP-S525D XVM-F65WL Reference
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101