Irox HBR556
|
|
Bookmark Irox HBR556 |
About Irox HBR556Here you can find all about Irox HBR556 like manual and other informations. For example: review.
Irox HBR556 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Irox HBR556 please write about it to help other people. [ Report abuse or wrong photo | Share your Irox HBR556 photo ]
Manual
Download
(English)Irox HBR556, size: 1.3 MB |
Irox HBR556
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
(3 ENG)-Page 33-48
1. INTRODUCTION
Congratulations on your purchase of the HBR556 radio weather station. The main appliance displays the weather forecast, the indoor and outdoor temperature/humidity and the time and date. The weather data are received by the external sensor. The 433 MHz technology used in the appliance means that no cables are needed between the outdoor sensor and the main appliance. The appliance is also equipped with a radio clock. The time is automatically synchronised with the time signal transmitter DCF77. If the appliance is located out of the range of the DCF77 signal, the time and date can also be set manually. The appliance has a barometer to reliably calculate the weather forecast. As a basic principle, the appliance does not need to be operated. The respective barometric pressure tendency of the previous 24 hours is depicted graphically.
WEATHER STATION WITH WEATHER FORECAST INDOOR/OUTDOOR RADIOTHERMO/HYGROMETER AND RADIO-CONTROLLED CLOCK (DCF77)
HBR556
INSTRUCTIONS FOR USE
IROX TE656NL & TS33C MANUAL (3 ENG) SIZE: W93 X H150 (mm) BY ROSE KOON 08/06/07
A LCD DISPLAY For the convenient reading of all values. B MODE KEY (BACK PANEL) Manual setting of clock / data (if required) C DOWN KEY ( ) - Reduces settings - Switch radio signal reception on/off - New search for the temperature sensor. D UP KEY ( ) - Increases settings - Keep pressed: Changes the display Barometric pressure Date (barometric pressure is not compensated at sea level) - Changes the display unit for the temperature display in degrees Celsius (C) or degrees Fahrenheit (F) E HOLDER FOR WALL HANGING For wall hanging F BATTERY COMPARTMENT For two batteries of the type UM-3 or AA. 1.5V alkaline batteries or better are recommended. G REMOVABLE STAND For setting the appliance up on a table
FEATURES OF THE THERMO/HYGRO TRANSMITTER UNIT HTS33
WIRELESS THERMO HYGRO
RESET 3 CHANNEL
A LED DISPLAY Flashes 1 x briefly during signal transmission and 2 x when battery is running out. B BATTERY COMPARTMENT For two batteries of the type UM-3 or AA. 1.5V alkaline batteries or better are recommended.
C RESET BUTTON Resetting of the appliance to the default settings and after a change of channel. D TRANSMISSION CHANNEL SELECTOR SWITCH Allocates channel 1, channel 2 or channel 3 to a sensor E HOLDER FOR WALL HANGING For wall hanging
F C/F SWITCH Switching between the temperature display in degrees Celsius (C) or degrees Fahrenheit (F) on the display unit.
2. PUTTING INTO OPERATION
2a) PLEASE READ BEFORE USE Please note the following instructions to ensure optimum operation of the appliances: - Place the receiver unit and the transmitter unit within 1 metre of one another. - Please follow the sequence described in 2b and 2e and wait until the measured value appears on the display. - Then install the receiver unit and the external transmitter unit within the possible range of the appliances, i.e. within a maximum radius of 30 metres. Please note that the actual range of the transmitters depends on the building materials of the respective building and on the respective position of the external transmitter unit and that the possible distance can be greatly reduced from the 30 metres by external influences (various radio transmitters and other sources of interference). In such cases, we recommend that you seek another position for both the transmitter and the receiver. Sometimes, moving them by just a few centimetres is sufficient! Although the external transmitter units are weatherproof, you should not position them in places where they are exposed to direct sunlight, rain or snow.
2c) PREPARATION OF THE RECEIVER UNIT 1. Open the cover of the battery compartment 2. Insert the 2 batteries (1.5 V, UM-3 or size AA) in accordance with the respective polarities. 3. Close the battery compartment again. 2d) BATTERY EMPTY DISPLAY When it is time to replace the battery with a new one, an indicator [ ] will appear next to the display of the indoor temperature (batteries receiver unit) or outdoor temperature (batteries transmitter unit) respectively. 2e) SETTING THE EXTERNAL SENSOR THERMO/HYGRO a. As soon as the batteries are in the outdoor sensor, the sensor starts to transmit the values measured in intervals of approx. 45 seconds. The main appliance also looks for signals (for approx. 2 minutes) as soon as the batteries are inserted. When the signal from the outdoor sensor is received, the outdoor temperature and the air humidity values appear on the display. b. If no sensor signals are received within 2 minutes, [ ] then appears on the display. Press the [ ] key for 3 seconds to initiate a search for the signals of the external sensor. In this way, you can synchronise the receiving and transmitting signal between the outdoor sensor and the main appliance. Important: The external sensor must be set to channel 1.
2b) PREPARATION OF THE EXTERNAL THERMO/GYRO TRANSMITTER UNITS 1. Remove the cover of the battery compartment. 2. Set channel 1 by moving the sliding switch (important: only set to channel 1!) 3. Insert the 2 batteries (1.5 V, UM-3 or size AA) in accordance with the respective polarities. 4. Press the RESET button (e.g. with a paper clip) 5. Screw down the cover of the battery compartment again.
3. WEATHER FORECAST
3a) WEATHER FORECAST Based on the change in barometric pressure, the receiver unit calculates the weather development for the next 12-24 hours and indicates this with the following symbols:
Symbols on the display Forecast Symbols on the display Forecast Rainy Strong rain Snow Sunny Slightly cloudy Clouded
3c) BAROMETRIC PRESSURE TENDENCY DISPLAY The indicator for the barometric pressure tendency in the weather forecast window indicates the trend in barometric pressure change in the previous hour. Three different indicators are displayed: Indicator
TREND TREND TREND
increasing Barometric pressure trend
staying the same
falling
3b) PLEASE NOTE THE FOLLOWING: 1. When the weather station has been put into operation, it is not necessary to set the current barometric pressure. The appliance will calculate over the next few hours a weather forecast from the changes in barometric pressure. 2. Lengthy, stable weather conditions make a weather forecast more difficult. A change in the weather symbol on the display may at times take longer than desired. 3. The weather forecast is calculated solely by means of changes in the barometric pressure. 4. The probability of the weather forecast is around 70% and applies for a radius of kilometres. 5. If the symbol sunny appears at night, this means cloudless weather. Fog is not displayed by the weather station as this can occur with different weather conditions. 6. If you take the weather station with you on your travels, the weather forecast will alter due to the differences in height above sea level and the resulting changes in barometric pressure. Please wait up to 24 hours until the weather station has calculated the weather forecast based on the barometric pressure conditions at your new location.
Note: By default, the barometric pressure measured is displayed in 'mbar/hPa'. The pressure is the pressure measured locally; it cannot be set to the sea level.
Frost alarm
The frost alarm symbol appears on the display when the outdoor temperature falls below 3C (This is transmitted by the external sensor on channel 1). When the temperature rises above +6C, the symbol disappears again.
4. RADIO CLOCK
4a) NOTES ABOUT THE RECEPTION OF THE TIME SIGNAL The appliance is designed in such a way that the calendar clock is automatically synchronised as soon as it is within the range of the DCF77 signal. To ensure a good reception of the time signal and minimise interference, you should not set up the appliance in the vicinity of metallic objects or electrical appliances. It normally takes around 3 to 5 minutes until the signal is fully received for the first time (depending on the strength of the time signal received). The subsequent hourly synchronisation of the time then only takes a few seconds. If the reception problems persist, please set the clock manually and wait until the next morning. The chances of successful reception are greater in the night (from midnight to around 4 am). One successful reception per week is perfectly sufficient to ensure that the clock runs precisely.
(flashing) reception active last reception was good last reception was not good or time was set manually No symbol Radio reception switched off
4b) MANUAL SETTINGS The appliance offers various options for changing the default settings. To do so, press the key [MODE] for three seconds to enter the setting mode. Every time the [MODE] key is pressed again, a flashing function which can be set appears on the display. Press one of the keys [ ] or [ ] respectively there. You can change the following functions (in this sequence; in between, simply press the [MODE] key each time): - Year - Calendar (Month Day Display Format (Day/Month or Month/Day) - Time format 24h or 12h - Time (hours minutes) 4c) Switching the radio reception off permanently You have the option of switching the radio reception on or off and using the appliance as a normal quartz clock. Press the [ ] button for 3 seconds to switch the radio reception on or off. When the radio reception is switched off, the receiving signal [ ] disappears from the display.
5. TECHNICAL DATA
Receiver unit Indoor temperature : -5C to +50C (23F to +122F) Relative measurement range : 25% to 95% Air humidity at 25C (77F) Resolution temperature : 0.1C 0.2C Resolution relative : 1% humidity External transmitter unit Measurement range Outdoor temperature Resolution temperature Transmission frequency Number of channels Range Measurement cycle Measurement range relative humidity Resolution relative humidity Power supply Receiver unit External transmission unit : -10C to +50C (23F to 122F) : 0.1C 0.2F : 433 MHz : 3 : Maximum 30 metres (in free field without interference) : approx. secs : 25% to 95% : 1%
Weights Receiver unit External transmitter unit Dimensions Receiver unit mm External transmitter unit
: 231g (without batteries) : 62g (without batteries) : 95(L) x 198(H) x 33.5 (D) : 55.5 x 101 x 24 mm
: 2 x UM-3 or AA 1.5V battery : 2 x UM-3 or AA 1.5V battery
CARE INSTRUCTIONS
1. Protect the appliance against moisture, dust, knocks and extreme temperatures and only clean it with a dry cloth without using an aggressive solvent. 2. Do not intervene in the appliance; otherwise, the guarantee will expire. 3. Please use only new batteries and never mix old and new batteries. Please also remember that old batteries should not be disposed of with household waste but should be handed in at the designated collection centres. Important: With all Irox appliances, all disposal fees in Switzerland (vRG; advance recycling fee) and in the EU (WEEE) have been paid.
EC Declaration of Conformity
Product: TE656 / HBR556 When used for its designated purpose, this product complies with the basic requirements of Article 3 of R&TTE 1999/5/EC Directive: Efficient use of radio frequency spectrum (Article 3.2 of the R&TTE Directive) Applied standard(s) EN 300 220-1,3:2000 Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) Applied standard(s) EN 301 489-1,3:2000 Applied standard(s) EN 300 339:200 Additional information: The product is thus compliant with the Low Voltage Directive 73/23/EEC and the Directive Regarding Electromagnetic Compatibility 89/336/EEC and bears the corresponding CE label.
PLEASE NOTE - Due to printing restrictions, the depiction of the display in these instructions for use may deviate from the actual display. Subject to change.
Compliant in the following countries: All EU countries, Switzerland and Norway CH and N
QA MANAGER : H.Y.WANG K.S plastic factory Guan Lan / Shen Shen / Cina

Remote Sensor Compatibility List Kompatibilittsliste Aussen-Sensoren Liste de compatibilit des capteurs extrieure
10. Dez 10
Product Produkt Produit
Sensor THR128 THN122
LCD cable
Thermometer HTS12C HTS22
LCD swimming
Thermo/Hygro HTS55 HTS45
LCD LCD
Channels AQUA EASY49 EASY79 EASY89 EBR606C EBR808C HBR31P HBR324 HBR325P HBR326P HBR329 HBR33 HBR425i HBR529 HBR555t HBR556 HBR558 HBR623i HBR636 HBR653 HBR657 HBVR761 HRG150 HT109 HT12 HT78 HTG77 HTG79 HTR21 HTR219 IBR923 JKBA-1 JKT-3R JKTG-4R Mete-on4 Mete-on7 Mete-on8 PRO-EC PRO-X PRO-X2 QPR505
x x i x x x x x x x x x x x x x i x x x x x x x x x x x x x x x x x x x x x i i i i i x i i i x x x x i x x x x x x x x x x x x x
i A A ab 2009
i x x x x i x x x x x x x x x x x x i x x x i x
A A A A A A A
x x x x x x x x x
x x i i i x i x x x x x x x x x i i x x x x x i
x x x x x x x x x x x x x x x x x x x x x x x x
x x x x x x x x x x x x x x x x x x x x x x x x i
A A A A A A A A A
x x x x
A A A i/A
x x x x x
A A A A A
i x x i i x x x x
x x x x x x x x x x x x x x x x x x x x x
A/i A/i A/I A/i A/i A/i
A additional or replacement remote sensors i originaly included x compatible as well
Zusatz oder Ersatz-Fhler original beigepackt auch kompatibel
sonde supplmentaire inclu original compatible de mme
Tags
SC-AK320 RD-JT21 DMC-FP8 Astra 3400 DAC-8 Yamaha SY77 Delta2 Recurve 1490T WM2355CW C-160 Globalnav II VDR-D150E ALL-IN-ONE DMR-XW400 D-NE300 Extreme 2 CCD-TR750E Metal Gear CF-21D10B EHT6435K Creed 50-2006 RE-1000 Sharepoint Review KX-FT936PD DVD-S33 Asterisk 36600 P60-1999 DSP128 CQ-C1305 C-70zoom LS-4000 Metz CT 52DC2D Zone-7 U8110 Ux-510 Satellite 1730 PC-1450 P42-H01-2 SF-2022 U500-17D DMC-FZ8 Gmrs100 Zoom 115 DCR-TRV103 L350D Gun G15 LN-T4066F IDE 1000 KV-32LS35B FP-6VH KV-21FQ10K DVP642 Fifa 2001 LC37XD1E Mw10C DAV-S400 Hdcsd10 Handheld M-6500A YS-624T Sport S10-3S GA-15 Reference Card Digital-modul R 1400W Vista Plus H2534Y33 KTC-V300N Ex-invisible WAR Dtxpress III WM30-96 LE40A796r2W MT 650 X3-reunion HTS3510 ZK25 10R LM560 Becker Z215 P5VD2-MX SET 820 BC-700 ADV350 A-1100 BDZ-T75 TRU5885-2 EX-P505 LA32C350d1 Dmcfz28 Qosmio F30 2-23 RE PV-DV51 KDC-MP2032CR CL-1 Nimh ND-BT1 BMW E32
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101







