Reviews & Opinions
Independent and trusted. Read before buy LG Starvert IG5!

LG Starvert IG5

 

 

LG Starvert IG5About LG Starvert IG5
Here you can find all about LG Starvert IG5 like manual and other informations. For example: review.

LG Starvert IG5 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a LG Starvert IG5 please write about it to help other people.
[ Report abuse or wrong photo | Share your LG Starvert IG5 photo ]

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
LG Starvert IG5 - Brochure, size: 536 KB

LG Starvert IG5

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

ower in Motion
LG Variable Frequency Drive(VFD) : Inverter

Starvert iG5

0.37 - 4.0kW (0.5 - 5.4HP) 1 and 3 phase 200 - 230 Volts, 3 phase 380 - 460 Volts

Contents

Overview Features & Selection Guide Specifications & Wiring Terminal Configuration, Keypad & Parameter Navigation Program Parameter Descriptions Dimension DB Resistor, Options & Peripheral Devices 14

Overview

Standard features
kW / Voltage Ratings: 0.5 ~ 2HP, 200-230VAC, 1phase 0.5 ~ 5HP, 200-230VAC, 3phase 0.5 ~ 5HP, 380-460VAC, 3phase Enclosure: IP00 ~ IP20 Inverter Type: PWM with IGBT Control Method: Volts / Hertz with Space Vector Technology Built-in RS-485 Built-in ModBus-RTU Built-in PID control Removable keypad (Able to read & write parameter) 150% torque at 0.5Hz Trip-free operation algorithm 8 preset speeds 3 jump(skip) frequencies 3 Multifuctional inputs 1 Multifuctional output Analog output (0~12V) PNP and NPN dual directional signals Speed search 3 wire operation 1 to 10 kHz carrier frequency Built-in Braking transistor Manual/Auto torque boost
Compact iG5, is the best for a small and cost effective configuration.

Options

Cable for Remote Keypad Operations(2,3 and 5 meters) DIN rail base for easy installation

Application

Converting Fan Pump Food processing machine Electric shutter Dryer Running machine Overheat Commercial washing machine Grinder Textile machine Material handling machine Centrifuge Elevator door Tooling machine
Conformity to global standards
UL and cUL listed for North America CE marked for Europe Quality process controlled by ISO9001, ISO14000

Reduced size

Enhancing its performance the iG5 shows much smaller size compares to the previous model, the iG series. Maximum 50% of total volume has been reduced in iG5 in order to mount it easily on smaller control panel and DIN rail with less weight. It allows more cost effective panel construction and system design.
Built-in communication interface and PC monitoring software
The iG5 has built-in the most popular communication interfaces such as Modbus-RTU and RS232/485. The iG5 has the small inverter features and standard medium drive features together. The "DriveviewTM" software offers Window based computer monitoring tool through RS485 interface with graphic capture, keypad emulator, parameter edit and text monitor. It is applicable for all LG inverters.

RS - 485 ModBus-RTU

Built-in PID control
It is valuable in process control. The built-in PID controller controls flow, temperature, pressure, etc. through the proportional, integral and differential calculus between the feedback value and reference value in closed loop.
Space vector PWM technology
The Space vector technology is being adopted in all LG drives. It features outstanding performance in its control characteristics. It has low total harmonic distortion, low current ripple, low torque ripple, low motor temperature rise, and better voltage utilization. It is a basic control platform of the iG5 drive. The advantages of Space vector PWM technology are being proved in many applications.
Better Efficiency (Low Iron Loss in Motor)
Low Total Harmonic Distortion
Low Motor Heat (Extended Motor) High Voltage Utilization (15.9%)

Low Torque Ripple

Low Current Ripple
Stable & Smooth Operation High and Stable Torque
Features & Selection Guide
Optimum acceleration and deceleration
To achieve a maximum torque during the acceleration and deceleration, "trip free" function is activated. The 32-bit DSP CPU monitors the current transition during the acceleration and deceleration to program an optimum curve that is under the trip-triggering level.

Stopped

CH1=2V DC 10:1 CH3=5V DC 10:1 CH4=2V DC 10:1 1s/div [1s/div] NORM:1kS/s
=Filter= =Offset= =Record Length= Main : 10k Zoom : 500 =Trigger= Mode : AUTO Type : EDGE CH1 Delay : 0.0ns Hold Off : MINIMUM =Filter= =Offset= =Record Length= Main : 10k Zoom : 500 =Trigger= Mode : AUTO Type : EDGE CH1 Delay : 0.0ns Hold Off : MINIMUM Smoothing : OFF Ch1 : 0.00V BW : FULL Ch2 : 0.00V CH3 : 0.00V CH4 : 0.00V Smoothing : OFF Ch1 : 0.00V BW : FULL Ch2 : 0.00V CH3 : 0.00V CH4 : 0.00V

Traditional curve

Optimum curve
PNP and NPN switchable duals signals
The iG5 has both PNP and NPN signals in order to controlled by PLC or outside controller. Regardless the type of PLC or type of control signal, iG5 can work with positive 24Vdc and negative 24Vdc.
Inverter rating selection guide
Inverter type nomenclature

SV 008 iG5 -4

LG Starvert drive

015. 220

0.37kW 0.75kW 1.5kW. 22kW

iG5 iS5 iH iV5

iG5 series iS5 series iH series* iV5 series

-1 -2 -4

1 phase 200~230V 3 phase 200~230V 3 phase 380~460V
* iH drive has a different designation in kW.
Specifications 200 ~230V Class(0.5~ 5.4 HP)
Drive Type (SV_ _ _iG5-_) [HP] 1) [kW] 2) Capacity[kVA]* FLA[A] Output ratings Frequency Voltage Voltage Input ratings Frequency Weight[kg] Braking circuit Average braking torque Braking torque Max. continuous braking time Max. duty Cooling method Enclosure Motor Rating* 004-1 0.5 0.37 1.008-2 015-2 022-2 037-5 0.75 1.5 2.2 3.7 1.4.5 6.~ 400 Hz 3) 200 ~ 230V* 1 phase 200 ~ 230 V( 10%) 3 phase 200 ~ 230 V( 10%) 50 ~ 60 Hz ( 5%) 50 ~ 60 Hz ( 5%) 2.1 1.2 1.2 1.8 2.1 2.2 1.8 On board 20% (with optional external braking resistor : 100%, 150%) 15 seconds 0 ~ 30 % ED Forced air cooling Natural Forced air cooling IP00 008-0.75 1.015-1.8 004-2 0.5 0.37 1.040-2 5.6.5 17

Specifications 380 ~460V Class(0.5~ 5.4 HP)
Drive Type (SV_ _ _iG5-_) 1) [HP] [kW] 2) Capacity[kVA]* FLA[A] Output ratings Frequency Voltage Voltage Input ratings Frequency Weight[kg] Weight [kg] Braking circuit Average braking torque Braking torque Max. continuous braking time Max. duty Cooling method Enclosure Motor Rating* 004-4 0.5 0.37 1.1 1.1 008-0.75 1.9 2.5 015-1.4 022-2.2 4.037-3.7 6.040-4 5.6.5 9
0 ~ 400 Hz 3) 380 ~ 460V* 3 phase 380 ~ 460 V( 10%) 50 ~ 60 Hz ( 5%) 1.8 2.1 1.7 On board 20% (with optional external braking resistor : 100%, 150%) 15 seconds 0 ~ 30 % ED Forced air cooling IP00
*1) Indicates the maximum applicable capacity when using 4 pole LG standard motor. *2) Rated capacity ( 3*V*I) is based on 220V for 200V class and 440V for 400V class. *3) Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be set.
Control method Frequency setting resolution Frequency accuracy Control V/F ratio Overload capacity Torque boost Operation method Frequency setting Start signal Input signal Multi-step Multi-step accel/decel time Emergency stop Jog Fault reset Output signal Operation status Fault output Indicator
V/F control Digital reference : 0.01 Hz (below 100 Hz), 0.1 Hz (over 100 Hz) Digital : 0.01% of max. output frequency Linear, Square pattern, User V/F 150 % of rated current for 1 min., 200% of rated current for 0.5 sec. (characteristic is inversely proportional to time) Manual torque boost (0 ~ 15 %), Auto torque boost Keypad / terminal / communication operation Analog : 0 ~ 10V / 4 ~ 20 mA Forward, Reverse Up to 8 speeds can be set (use multi-function terminal) 0 ~ 6,000 sec, up to 8 types can be set and selected for each setting (use the multi- function terminal), Accel/Decel pattern : linear pattern, U pattern, S pattern, Optimum, Minimum Interrupts the output of the drive Jog operation Resets fault when protective function is active Frequency level detection, Overload alarm, stalling, overvoltage, undervoltage, drive overheating, running, stop, constant speed, speed searching Contact output (30A,30C,30B) - AC250V 1A, DC30V 1A Choose 1 from output frequency, output current, output voltage, DC voltage (Output pulse: 500Hz, Output voltage: 0 ~ 10V) DC braking, frequency limit, frequency jump, second function, slip compensation, reverse rotation prevention, auto restart, PID control Digital : keypad Analog reference : 0.03 Hz / 50 Hz Analog : 0.1% of max. output frequency

Operation

Operation function Drive trip Protective function Display Keypad Inverter alarm Momentary power loss Operation information Trip information Ambient temperature Storage temperature Environment Ambient humidity Altitude. Vibration Application site

Overvoltage, undervoltage, overcurrent, drive overheating, motor over heating, input/output phase loss, input/output mis-wiring, overload protection, communication error, loss of speed command, hardware fault. Stall prevention, overload alarm Less than 15 msec : continuous operation, more than 15 msec : auto restart possible Output frequency, output current, output voltage, frequency value setting, operating speed, DC voltage Indicates the fault when the protection function activates, memorizes up to 5 faults -10 C ~ 40 C -20 C ~ 65 C 90 % RH max.(Non condensing) Below 1,000 m below 5.9m/sec2(=0.6g) No corrosive gas, combustible gas, oil mist, or dust
Specifications & Wiring

Wiring

DB Resistor*2
MCCB 1 230V or 3 230/460V 50/60Hz R S T G
24 Forward Run/Stop Reverse Run/Stop Drive gate block Fault Reset Jog Multi-function Input 1 Multi-function Input 2 Multi-function Input 3 Common Terminal

B2 U V W

+ FM FM Output Frequency Meter (0 ~ 12V : pulse output)
FX RX BX RST JOG P1 P2 P3 CM Factory Setting `Speed-L` `Speed-M` `Speed-H` A C B CM
Fault output relay Iess than AC250V, 1A Iess than DC30V, 1A
Potentiometer (1kohm, 1/2W)
Shield MO Power supply for VR speed signal: +12V, 100mA V1 Speed signal input: 0 ~10V I Speed signal input: 4 ~ 20mA(250ohm) CM Common for VR, V1, I S+ SModBus-RTU RS-485 Communication port MG Multi-function output Iess than DC24V, 50mA Factory setting:`RUN`

Speed signal Input*1

" " display main circuit terminals, " " display control circuit terminals. 1. Analog speed command can be set by Voltage, Current and both of them. 2. DB resistor is optional.
Power terminal configuration
Symbol R S T U V W B1 B2 G Function AC Line input (1 phase 200~230 Vac for "-1" units 3 phase, 200~230 Vac for "-2" units and 380~460 Vac for "-4" units)
3 phase output terminals to motor
External additional dynamic braking resistor connection terminals. Chassis ground (The gound terminal("G") may be located on heat sink instead of terminal strip depend on the model name)
Control terminal configuration
Type Symbol P1, P2, P3 FX RX JOG BX Name Multi function input 1,2,3 Forward run command Reverse run command Jog frequency reference Drive gate block Descripton Used for multi function input. Factory default is set to step frequency 1, 2, 3. Forward run when closed and stop when opened. Reverse run when closed and stop when opened. Runs at jog frequency when the jog signal is on. The direction is set by the FX (or RX) signal. Starting Contact When the BX signal is ON, the output of the drive is cut off. When the motor uses an mechanical brake to stop, Function Slection BX is used to cut off the output signal. When the BX signal, which does not cut off by latching, is OFF and the FX signal (or the RX signal) is ON, the motor keeps running, so be cautious. RST Used to release the protective status when the protective circuit is active. Fault reset CM Used for the common terminal for contact input terminals. Sequence common VR Used as power for the analog frequency setting. Maximum output is +12V, 100mA. Frequency setting power(+12V) Analog Frequency V1 Used for frequency reference and uses 0-10V for input. Input resistance is 20 k Frequency reference (Voltage) Setting I Used for frequency reference and uses DC 4-20mA for input. Input resistance is 250 Frequency reference(Current) CM Frequency setting common terminal Common terminal for the analog frequency reference signal and the FM (for monitoring). FM.CM Analog/digital output Outputs one of the followings: output frequency, output current, output voltage, DC link voltage. Factory default is set to output frequency. Maximum output voltage and output current is 0-12V, 1mA. (For external monitoring) Pulse Output frequency is set to 500Hz. 30A, 30C, 30B Fault contact output Activates when the protective function is operating. AC250V 1A or less, DC30V 1A or less Fault : 30A-30C short (30B-30C open) Nomal : 30A-30C short (30B-30C open) Contact MO.MG Multi-function output Used for multi-function output (Open collector output) S+, SCommunication ports for RS-485 Communication port RS232

Keypad

Class Display FUNC UP KEY DOWN RUN STOP/RESET REV LED FWD SET RUN Name Program key Up key Down key Run key STOP/RESET key Reverse run Forward run Setting Operating Description Press to change the parameter setting. Press to move through codes or to increase the parameter values. Press to move through codes or to decrease the parameter values. Use to operate the drive Press to stop during operation. Press to reset when a fault has occurred. During reverse run. During forward run. When the user is setting the parameters using the FUNC key When in constant speed and blinks when accelerating or decelerating.

Parameter group

Output signal

Input signal

Group name
Description Basic parameters of Command frequency, Accel/Decel time etc. Basic parameters of Max. Frequency, Torque boost etc. Application parameters of Frequency jump, Frequency limit etc. Multifunction terminal setting and Sequence operation parameters
Drive Group Function 1 Group Function 2 Group Input / Output Group
Terminal Configuration, Keypad & Parameter Navigation

Parameter navigation

1. Drive Group

SET RUN FWD REV

SET RUN

FWD REV

2. Function Group

3. I/O Group

FWD REV SET RUN

FU I F O

I0 I 0
Program parameter descriptions

1. Drive Group [DRV]

Code DRV-00 DRV-01 DRV-02 DRV-03 Description Output Frequency during running, Reference Frequency during stop Acceleration Time Deceleration Time Drive Mode (Run/Stop method) Keypad Display 0.00 ACC Setting Range 0 to Max. Freq. (FU1-20) 0 to 6000 [sec] 0 to 6000 [sec] 0 (keypad) 1 (Keypad-2) 2 (Fx/Rx-2) 3 (ModBus-RTU) 0 [Keypad-1] 1 (Keypad-2) 2 (V1) 3 (I) 4 (V1+I) 5 (ModBus-RTU) Starting freq (FU1-22) to Max. freq (FU1-20) Units 0.01 0.1 0.1 Factory Default 60.00 [Hz]* 10.0 [sec] 10.0 [sec] 1 Adjustable during run Yes Yes Yes No

DRV-04

Frequency Mode (Freq. setting method)
DRV-05 DRV-06 DRV-07 DRV-08 DRV-09 DRV-10 DRV-11 DRV-12 DRV-13 DRV-20 DRV-21 DRV-22
Step Frequency 1 Step Frequency 2 Step Frequency 3 Output Current Motor Speed DC link Voltage User Display selection Fault Display Motor Direction set FU1 Group selection FU2 Group selection I/O Group selection

0.01 0.01 0.01 -

10.00 [Hz] 20.00 [Hz] 30.00 [Hz] - [A] - [rpm] - [V] nOn F
* [A] * [rpm] * [V] Selected in FU2-73 (User disp) F (Forward) r (Reverse)

2. Function Group1[FU1]

FU1-00 FU1-03 Jump to desired code # Run Prevention F0 Fto (None) 1 (Forward Prev) 2 (Reverse Prev) 0 (Linear) 1 (S-curve) 2 (U-curve) 3 (Minimum) 4 (Optimum) 0 (Linear) 1 (S-curve) 2 (U-curve) 3 (Minimum) 4 (Optimum) 0 (Decel) 1 (DC-brake) 2 (Free-run) FU1-22 to 50 [Hz] 0 to 60 [sec] 0 to 200 [%] 0 to 60 [sec] 0 to 200 [%] 0 to 60 [sec] 40 to 400 [Hz] 30 to FU1-20 0.1 to 10 [Hz] 0 (No) 1 (Yes) FU1-22 to FU1-25 FU1-24 to FU1-(Manual) 1 (Auto) 0 to 15 [%] 0 to 15 [%] 0 (Linear) 1 (Square) 2 (User V/F) 0 to FU1-to 100 [%] FU1-30 to FU1-to 100 [%] FU1-32 to FU1-to 100 [%] FU1-34 to FU1-to 100 [%] 40 to 110 [%] 0 to 30 [%] 0 (No) 1 (Yes) FU1-52 to 150 [%] 50 to FU1-(Self-cool) 1 (Forced-cool) 0 Yes No

FU1-05

Acceleration Pattern

FU1-06

Deceleration Pattern

FU1-07

Stop Mode
FU1-08 FU1-09 FU1-10 FU1-11 FU1-12 FU1-13 FU1-20 FU1-21 FU1-22 FU1-23 FU1-24 FU1-25 FU1-26 FU1-27 FU1-28 FU1-29
DC Injection Braking Frequency DC Injection Braking On-delay Time DC Injection Braking Voltage Starting DC Injection Braking Time Starting DC Injection Braking Voltage Starting DC Injection Braking Time Maximum Frequency Base Frequency Starting Frequency Frequency Limit selection Low Limit Frequency High Limit Frequency Manual/Auto Torque Boost selection Torque Boost in Forward Direction Torque Boost in Reverse Direction Volts/Hz Pattern
F8 F9 FI0 FI I FI2 FI3 F20 F2 I F22 F23 F24 F25 F26 F27 F28 F29
0.01 0.0.0.1 0.01 0.01 0.01 0.01 0.01 0.1 0.1 -
5.00 [Hz] 0.5 [sec] 50 [%] 1.0 [sec] 50 [%] 0.0 [sec] 60.00 [Hz]* 60.00 [Hz]* 0.50 [Hz]
No No No No No No No No No No No No No No No No
0.50 [Hz] 60.00 [Hz]* 0 5.0 [%] 5.0 [%] 0
FU1-30 FU1-31 FU1-32 FU1-33 FU1-34 FU1-35 FU1-36 FU1-37 FU1-38 FU1-39 FU1-50 FU1-51 FU1-52 FU1-53
User V/F - Frequency 1 User V/F - Voltage 1 User V/F - Frequency 2 User V/F - Voltage 2 User V/F - Frequency 3 User V/F - Voltage 3 User V/F - Frequency 4 User V/F - Voltage 4 Output Voltage Adjustment Energy Save Level F39 Electronic Thermal selection Electronic Thermal Level for 1 minute Electronic Thermal Level for continuous Electronic Thermal Characteristic selection (Motor type)

F30 F3 I F32 F33 F34 F35 F36 F37 F38 F39 F50 F5 I F52 F53

0.0.0.0.0.-

15.00 [Hz]* 25 [%] 30.00 [Hz]* 50 [%] 45.00 [Hz]* 75 [%] 60.00 [Hz]* 100 [%] 100[%] 0 [%] [%] 150 [%] 0
No No No No No No No No No Yes Yes Yes Yes Yes
Program Parameter Descriptions
Factory Default 150 [%] 10.0 [sec] [%] 60.0 [sec] 000 Adjustable during run Yes Yes Yes Yes No
Code FU1-54 FU1-55 FU1-56 FU1-57 FU1-58 FU1-59
Description Overload Warning Level Overload Warning Hold Time Overload Trip selection Overload Trip level Overload Trip Delay Time Stall Prevention Mode selection
Keypad Display F54 F55 F56 F57 F58 F59
Setting Range 30 to 150 [%] 0 to 30 [sec] 0 (No) 1 (Yes) 30 to 200 [%] 0 to 60 [sec] 000 - 111 (bit set) Bit 0: during Accel. Bit 1: during Steady speed Bit 2: during Decel. 30 to 150 [%]

Units 1 0.1 bit

FU1-60 FU1-99
Stall Prevention Level Return Code

150 [%] -

3. Function Group2 [FU2]
FU2-00 FU2-01 FU2-02 FU2-03 FU2-04 FU2-05 FU2-06 FU2-07 FU2-08 FU2-10 FU2-11 FU2-12 FU2-13 FU2-14 FU2-15 FU2-16 FU2-19 Jump to desired code # Previous Fault History 1 Previous Fault History 2 Previous Fault History 3 Previous Fault History 4 Previous Fault History 5 Erase Fault History Dwell Frequency Dwell Time Frequency Jump selection Jump Frequency 1 Low Jump Frequency 1 High Jump Frequency 2 Low Jump Frequency 2 High Jump Frequency 3 Low Jump Frequency 3 High Input/Output Phase Loss Protection H0 HI H2 H3 H4 H5 H6 H7 H8 HI0 HI I HI2 HI3 HI4 HI5 HI6 HIto nOn nOn nOn nOn 0 5.00 [Hz] 0.0 [sec] 0 0.00 [Hz] 0.00 [Hz] 0.00 [Hz] 0.00 [Hz] 0.00 [Hz] 0.00 [Hz] 00 Yes Yes Yes Yes Yes No No No No No No No No No Yes

FU2-20 FU2-21 FU2-22

Power ON Start selection Restart after Fault Reset Speed Search selection

H20 H2 I H22

FU2-23 FU2-24 FU2-25 FU2-26 FU2-27 FU2-30 FU2-31 FU2-32 FU2-33 FU2-34 FU2-36 FU2-37 FU2-39 FU2-40
Current Limit Level during Speed Search P Gain during Speed Search I Gain during speed search Number of Auto Restart Attempt Delay Time before Auto Restart Rated Motor selection Number of Motor Poles Rated Motor Slip Rated Motor Current in RMS No Load Motor Current in RMS Motor Efficiency Load Inertia Carrier Frequency Control Mode selection
H23 H24 H25 H26 H27 H30 H3 I H32 H33 H34 H36 H37 H39 H40
FU2-50 FU2-51 FU2-52 FU2-53 FU2-54 FU2-70 FU2-71
PID Feedback Signal selection P Gain for PID Control I Gain for PID Control D Gain for PID Control Limit Frequency for PID Control Reference Frequency for Accel and Decel Accel/Decel Time Scale
H50 H5 I H52 H53 H54 H70 H7 I

FU2-72

Power On Display
0 (No) 1 (Yes) 0 to FU1-to 10 [sec] 0 (No) 1 (Yes) FU1-22 to FU2-12 FU1-11 to FU2-20 FU1-22 to FU2-14 FU2-13 to FU1-20 FU1-22 to FU2-16 FU2-15 to FU1-- 11 (bit set) Bit 0: Output phase loss protection Bit 1: Intput phase loss protection 0 (No) 1 (Yes) 0 (No) 1 (Yes) 0000 - 1111 (bit set) Bit 0: during Accel. Bit 1: after fault reset Bit 2: after instant power failure restart Bit 3: when FU2-20 is set to 1 (Yes). 80 to 200 [%] 0 to to to to 60 [sec] 0.4 (0.37kW) 0.8 (0.75kW) 1.5 (1.5kW) 2.2 (2.2kW) 2 to to 10 [Hz] 0.1 to 99.9 [A] 0.1 to 99.9 [A] 50 to 100 [%] 0 to to 10 [kHz] 0 (V/F) 1 (Slip Compen) 2 (PID) 0 (I) 1 (V1) 0 to to to to FU1-(Max Freq) 1 (Delta Freq) 0 (0.01 sec) 1 (0.1 sec) 2 (1 sec) 0 (Cmd. Freq) 1 (Acc. Time) 2 (Dec. Time) 3 (Drv mode) 4 (Freq mode) 5 (Step Freq 1) 6 (Step Freq 2) 7 (Step Freq 3) 8 (Current) 9 (Speed) 10(DC link Vtg) 11 (User disp) 12 (Fault Display) 13 (Motor direction)
0.01 0.1 0.01 0.01 0.01 0.01 0.01 0.01 -

Yes Yes No

100 [%] 0 1.0 [sec]
Yes Yes Yes Yes Yes No No No No No No No Yes No

1 0.01 -

60.00 [Hz]* 0 1
No Yes Yes Yes Yes No Yes
Factory Default 0 Adjustable during run Yes

Code FU2-73

Description User Display selection

Keypad Display H73

Setting Range 0 (Voltage) 1 (Watt) 2 (Torque) 1 to 1000 [%] 0 [None] 1 [None] 2 (Ext.DB-R) 0 to 30 [%] 0 to 6000 [sec] 0 to 6000 [sec] 30 to FU1-(Linear) 1 (Square) 2 (User V/F) 0 to 15 [%] 0 to 15 [%] 30 to 150 [%] FU2-89 to 150 [%] 50 to FU2-88(maximum 150%) 0.1 to 99.9 [A] 0 (No) 1 (Yes) 0 (No) 1 (Yes) 0 (No) 1 (All Groups) 2 (DRV) 3 (FU1) 4 (FU2) 5 (I/O) 0 to 255

Units -

FU2-74 FU2-75
Gain for Motor Speed Display DB(Dynamic Braking)Resistor Mode selection Duty of Dynamic Braking Resistor Software Version 2nd Acceleration Time 2nd Deceleration Time 2nd Base Frequency 2nd V/F Pattern

H74 H75

100 [%] 0

Yes Yes

FU2-76 FU2-79 FU2-81 FU2-82 FU2-83 FU2-84

H76 H79 H8 I H82 H83 H84

1 0.1 0.1 0.01 -
10 [%]. E 5.0 [sec] 10.0 [sec] 60.00 [Hz]* 0

Yes Yes Yes No No

FU2-85 FU2-86 FU2-87 FU2-88 FU2-89 FU2-90 FU2-91 FU2-92 FU2-93
2nd Forward Torque Boost 2nd Reverse Torque Boost 2nd Stall Prevention Level 2nd Electronic Thermal Level for 1 minute 2nd Electronic Thermal Level for continuous 2nd Rated Motor Current Read Parameters into Keypad from Inverter Write Parameters to Inverter from Keypad Initialize Parameter
H85 H86 H87 H88 H89 H90 H9 I H92 H93

0.1 0.0.1 -

5.0 [%] 5.0 [%] 150 [%] 150 [%] 100 [%] 1.8 [A] 0
No No No Yes Yes No No No No

FU2-94 FU2-99

Parameter Write Protection Return Code
4.Input / Output Group [I/0]
Code I/O-00 I/O-01 I/O-02 I/O-03 I/O-04 I/O-05 I/O-06 I/O-07 I/O-08 I/O-09 I/O-10 I/O-11 Description Jump to desired code # Filtering Time Constant for V1 Signal Input V1 Input Minimum Voltage Frequency corresponding to V1 Input Minimum Voltage V1 Input Maximum Voltage Frequency corresponding to V1 Input Maximum Voltage Filtering Time Constant for I Signal Input I Input Minimum Current Frequency corresponding to I Input Minimum Current I Input Maximum Current Frequency corresponding to I Input Maximum Current Criteria for Analog Input Signal Loss Keypad Display I I I I I I I I I I I I 0 I I0 II Setting Range 1 to to 9999 [ms] 0 to I/O-to FU1-20 I/O-02 to 10 [V] 0 to FU1-to 9999 [ms] 0 to I/O-to FU1-20 I/O-07 to 20 [mA] 0 to FU1-(None) 1 (Half of x1) 2 (Below x1) 0 (Speed-L) 1 (Speed-M) 2 (Speed-H) 3 (XCEL-L) 4 (XCEL-M) 5 (XCEL-H) 6 (Dc-brake) 7 (2nd Func) 10 (Up) 11 (Down) 12 (3-Wire) 13 (Ext trip-A) 14 (Ext trip-B) 16 (Open-loop) 17 (Main-drive) 18 (Analog hold) 19 (XCEL stop) Same as above Same as above 00000000 - 11111111 (bit set) 0 - 1 (bit set) 2 to 50 FU1-22 to FU1-20 FU1-22 to FU1-20 FU1-22 to FU1-20 FU1-22 to FU1-20 FU1-22 to FU1-to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] Units 0.01 0.01 0.01 0.0.01 0.01 0.01 0.01 Factory Default 1 1,000 [ms] 0.00 [V] 0.00 [Hz] 10.00 [V] 60.00 [Hz]* 1,000 [ms] 4.00 [mA] 0.00 [Hz] 20.00 [mA] 60.00 [Hz]* 0 Adjustable during run Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

I/O-12

Multi-function Input Terminal 'P1' define 8,9, 15, 20, 21, 22, 23, 24, 25, 26(-Reserved-)
I/O-13 I/O-14 I/O-15 I/O-16 I/O-17 I/O-20 I/O-21 I/O-22 I/O-23 I/O-24 I/O-25 I/O-26 I/O-27 I/O-28 I/O-29 I/O-30
Multi-function Input Terminal 'P2' define Multi-function Input Terminal 'P3' define Terminal Input Status Terminal Output Status Filtering Time Constant for Multi-function Input Terminals Jog Frequency setting Step Frequency 4 Step Frequency 5 Step Frequency 6 Step Frequency 7 Acceleration Time 1 for Step Frequency Deceleration Time 1 for Step Frequency Acceleration Time 2 Deceleration Time 2 Acceleration Time 3 Deceleration Time 3
I I I I I I I I I I I I I I I I

I3 I4 I5 I6 I2I 30

1 0.01 0.01 0.01 0.01 0.1 0.1 0.1 0.1 0.1 0.1 0.1
15 10.00 [Hz] 40.00 [Hz] 50.00 [Hz] 40.00 [Hz] 30.00 [Hz] 20.0 [sec] 20.0 [sec] 30.0 [sec] 30.0 [sec] 40.0 [sec] 40.0 [sec]
No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes

Dimension

Factory Default 50.0 [sec] 50.0 [sec] 40.0 [sec] 40.0 [sec] 30.0 [sec] 30.0 [sec] 20.0 [sec] 20.0 [sec] 0 Adjustable during run Yes Yes Yes Yes Yes Yes Yes Yes Yes
Code I/O-31 I/O-32 I/O-33 I/O-34 I/O-35 I/O-36 I/O-37 I/O-38 I/O-40
Description Acceleration Time 4 Deceleration Time 4 Acceleration Time 5 Deceleration Time 5 Acceleration Time 6 Deceleration Time 6 Acceleration Time 7 Deceleration Time 7 FM (Frequency Meter) Output selection
Keypad Display I I I I I I I I I 3I 38 40
Setting Range 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 to 6000 [sec] 0 (Frequency) 1 (Current) 2 (Voltage) 3 (DC link Vtg) 10 to 200 [%] 0 to FU1-to FU1-(FDT-1) 1 (FDT-2) 2 (FDT-3) 3 (FDT-4) 4 (FDT-5) 5 (IOL) 6 (IOL) 7 (Stall) 8 (OV) 9 (LV) 10 (OH) 11 (Lost Command) 12 (Run) 13 (Stop) 14 (Steady) 17 (Search) 000 - 111 (bit set) Bit 0: LV Bit 1: All Trip Bit 2: Auto retry 1 to (1200 bps) 1 (2400 bps) 2 (4800 bps) 3 (9600 bps) 4 (19200 bps) 0 (None) 1 (FreeRun) 2 (Stop) 0.1 to 120 [sec] 0 (LG- BUS) 1~6(ModbusASCII) 7~9 (Modbus-RTU)
Units 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 -
I/O-41 I/O-42 I/O-43 I/O-44
FM Output Adjustment Frequency Detection Level Frquency Detection Bandwidth Multi-function Output define (MO)15, 16, 18, 19, 20(-Reserved-)

I I I I

1 0.01 0.01 -
100 [%] 30.00 [Hz] 10.00 [Hz] 12

Yes Yes Yes Yes

I/O-45
Fault Output Relay setting (30A, 30B, 30C)

I/O-46 I/O-47

Inverter Number Baud Rate I47

I 46 I 47

I/O-48
Operating selection at Loss of Freq. Reference

I/O-49 I/O-50

Waiting Time after Loss of Freq. Reference Communication Protocol selection

I 49 I 50

1.0 [sec] 7

I/O-99

Return Code
Note: Parameters that are set by bit are ON (1) when the upper LED is lit. (F59, H19, H22, I15, I16, I45 are the parameters that are set by bit.) Note: *marked default value changes depend on the main frequency setting in factory(50 / 60Hz)

Dimension : mm(inch)

VARIABLE FREQUENCY DRIVER
SOURCE AC200-230V 50/60Hz OUTPUT CAPACITY 1.5kVA CURRENT 5A FRCQUENCY 0.2-400Hz

FUNC RUN STOP RESET

International system Co, Ltd Made In Korea

SV015IG5-2

CAUTION
Read the manual and follow the safety instruction before installation or operation Do not the power supply to the drive output terminal (U, V, W) Before opening the cover, disconnect all power and wait at least 3 minutes untill DC bus capacitors discharge. `Risk of Electric Shock`-more than one disconnect switch is required to de energize the equipment before servicing.

4.5 W2 W1

Inverter SV004iG5-1 SV004iG5-2 SV008iG5-1 SV008iG5-2 SV015iG5-1 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4

HP 0.5 0.5 5.4 0.5 5.4

W1 100(3.94) 100(3.94) 130(5.12) 100(3.94) 150(5.90) 130(5.12) 150(5.90) 150(5.90) 150(5.90) 130(5.12) 130(5.12) 130(5.12) 150(5.90) 150(5.90) 150(5.90)
W2 88(3.46) 88(3.46) 118(4.65) 88(3.46) 138(5.43) 118(4.65) 138(5.43) 138(5.43) 138(5.43) 118(4.65) 118(4.65) 118(4.65) 138(5.43) 138(5.43) 138(5.43)
H1 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04) 128(5.04)
H2 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63) 117.5(4.63)
D1 130.9(5.15) 130.9(5.15) 150.9(5.94) 130.9(5.15) 155(6.10) 150.9(5.94) 155(6.10) 155(6.10) 155(6.10) 150.9(5.94) 150.9(5.94) 150.9(5.94) 155(6.10) 155(6.10) 155(6.10)

Dynamic Braking(DB) Resistors

1. Standard application

Drive SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Resistor capacity [W] 100 Resistor value[ ] 200 Average braking torque[%] 100 Enable duty[%] 2 Continuous braking time[sec] 5
2. When the braking magnitude is high
Drive SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Drive SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Resistor capacity [W] 500 Resistor capacity [W] 600 Resistor value[ ] 200 Resistor value[ ] 130 Average braking torque[%] 100 Average braking torque[%] 150 Enable duty[%] 5 Enable duty[%] 5 Continuous braking time[sec] 5 Continuous braking time[sec] 5
Option DIN Rail base Remote keypad mounting fixture and cable Description Din rail mounting plate 2 meter, 3 meter and 5 meter cable and mounting fixture.

Peripheral devices

Drive Models SV004iG5-1 SV008iG5-1 SV015iG5-1 SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 kW 0.37 0.75 1.5 0.37 0.75 1.5 2.2 3.0.37 0.75 1.5 2.2 3.MCCB, ELB ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 ABS33a, EBS33 Magnetic Contactor SMC-10P SMC-10P SMC-10P SMC-10P SMC-10P SMC-10P SMC-15P SMC-20P SMC-20P SMC-10P SMC-10P SMC-10P SMC-20P SMC-20P SMC-20P R,S,T 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) Wire, mm2(AWG) U,V,W Ground 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 3.5(12) 2(14) 2(14) 2(14) 2(14) 2(14) 2(14) AC Input 10A 10A 10A 10A 10A 15A 25A 40A 40A 6A 6A 10A 10A 20A 20A AC Reactor 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 2.13mH, 5.7A 1.20mH, 10A 0.88mH, 14A 0.56mH, 20A 0.56mH, 20A 8.63mH, 2.8A 8.63mH, 2.8A 4.81mH, 4.8A 3.23mH, 7.5A 2.34mH, 10A 2.34mH, 10A DC Reactor 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 7.00mH, 5.4A 4.05mH, 9.2A 2.92mH, 13A 1.98mH, 19A 1.98mH, 19A 28.62mH, 2.7A 28.62mH, 2.7A 16.14mH, 4.6A 11.66mH, 7.1A 7.83mH, 10A 7.83mH, 10A

DB Resistor, Options & Peripheral Devices

RFI Filters

IG5 Series Drive Models SINGLE PHASE SV004iG5-1 SV008iG5-1 SV015iG5-1 THREE PHASE SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 IG5 Series Drive Models SINGLE PHASE SV004iG5-1 SV008iG5-1 SV015iG5-1 THREE PHASE SV004iG5-2 SV008iG5-2 SV015iG5-2 SV022iG5-2 SV037iG5-2 SV040iG5-2 SV004iG5-4 SV008iG5-4 SV015iG5-4 SV022iG5-4 SV037iG5-4 SV040iG5-4 Power Code Current Power Code Current Footprint Filter Tension Voltage (max.) 250VA 250VA 250VA (max.) 250VA 250VA 250VA Leakage Current 3.5A 3.5A 3.5A 0.3A 18A 0.3A 18A 0.3A 18A Dimensions LWH 173.5 X 103.5 X 40 173.5 X 133.5 X 40 173.5 X 153.5 X 40 173.5 X 103.5 X 40 173.5 X 133.5 X 40 173.5 X 153.5 X 40 Mounting YX 159.5 X 80 159.5 X 110 159.5 X 130 159.5 X 80 159.5 X 110 159.5 X 130 Weight Mount Output Chokes FS-1 FS-1 FS-2 FS-1 FS-2 FS-2
0.4kW 0.8kW 1.5kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW
FFG5-M010-1 FFG5-M011-1 FFG5-M020-1 FFG5-T005-1 FFG5-T012-1 FFG5-T020-1

10A 11A 20A 5A 12A 20A

M4 M4 M4 M4 M4 M4

FFG5-T006-1

380VAC

0.5A 27A

173.5 X 133.5 X 40

159.5 X 110

FFG5-T011-1

159.5 X 130

Standard Filter Tension Voltage (max.) 0.4kW 0.8kW 1.5kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW 0.4kW 0.8kW 1.5kW 2.2kW 3.7kW 4.0kW FEG5-T010-(X) FEG5-T015-(X) FEG5-T006-(X) FEG5-T012-(X) FEG5-T020-(X) 10A 15A 6A 12A 20A 250VA 250VA (max.) 250VA 250VA 250VA 3.5A 3.5A 0.3A 18A 0.3A 18A 0.3A 18A 150.5 X 55 X 45 150.5 X 55 X X 110 X X 110 X X 140 X X X X X X 106 ----------FS-1 FS-2 FS-2 FS-2 FS-2 Leakage Current Dimensions LWH Mounting YX Weight Mount Output Chokes

FEG5-T006-(X)

250 X 110 X 60

238 X 76

FEG5-T012-(X)
(X) (1) Industrial environment EN 50081-1 (A class) (2) Domestic and industrial environment EN 50081-1 (B class)

FF Series (Footprint)

FE Series (Standard)
FS Series (output chokes)

D 21 28.58

W 150 200

H 110 170

X 125 x x 45

FS-1 FS-2 FS-3 FS-4

INVERTER

FILTER

SHIELDED CABLE

INVERTER FILTER

LG constantly endeavor to improve our products so that information in this catalog is subject to change without notice.
HEAD OFFICE LG TWIN TOWERS, 20 Yoido-dong, Youngdungpo-gu, Seoul, 150-721, Korea. Tel.(82-2)3777- 4640 ~ 4649 Fax.(82-2)3777- 4648 http://www.lgis.com http://www.fasolution.com OVERSEAS BRANCHES Beijing Tel.86-10-6462-3254, 3256, 3259, 6464-8637 Shanghai Tel.86-21-6252-3367, 3795, 6240-3477 Hanoi Tel.84-4-882-0222 Dalian Tel.86-411-730-6495, 730-7580 Tokyo Tel.81-3-3582-9126 Jakarta Tel.62-21-897-4311 New Jersey Tel.1-201-816-2982

doc1

Leader in Electrics & Automation

Starvert iG5A

Economic type intelligent inverter, extended its capability up to 7.5kW
5.5~7.5kW 3 Phase 200~230V, 380~460V

Automation Equipment

Release Starvert
LG Starvert iG5A is very competitive in its price and shows an upgraded functional strength compared to iG5. User-friendly interface, extended inverter ranges up to 7.5kW, superb torque competence and small size of iG5A provides an optimum use environment.

Starvert

ISO9001 ISO14000

CE, UL

Flexibility
Sensorless vector control high torque Built-in sensorless vector control realizes the superb speed control and powerful high torque. Ground-fault protection function during running Ground-fault protection of output terminal is possible during running. Cooling fan control according run pattern By controlling the cooling fan, iG5A provides a virtually quite environment according motors run and stop. Auto carrier frequency changes according temperature When the internal temperature of the inverter increses too high, it is detected and then the inverter controls the carrier frequency automatically. This function automatically eliminates the temperature increase factor of inverter, thereby it keeps a sounded operation.
Speed vs Torque Characteristics

Torque (%)

Speed (Hz)

Condition:

Sensorless Vector Control Mode : Auto tuning Measure maximum torque(%) at each speed (1/5/10/20/30/40/50/60Hz)
More convenient interface The parameter setup became easier by adopting the 4 directions key. Easy change of the fan In case of the fan breakdown, it is always changeable by the user as iG5A has been designed to a easy fan changeable structure.
Built-in communication By the built-in the RS485 LG bus and the Modbus-RTU communications iG5A came to easy application to the communication environment.
Built-in PID control The built-in process PID function enables controlling the flow-rate,oil-pressure, temperature etc, without any extra controller. Control from -10V to +10V Controlling forward and reverse run became possible with inputting voltage signals that ranges from -10V to +10V. PNP/NPN input Both PNP and NPN inputs became possible and these enable to use the outer power. To do so, the user will be given wider choices of selecting the controller.

Converter

Specifications

Rated input/output

SV iG5A- Motor Rated output

Note 1

Capacity Current Frequency Voltage [V] [V] Rated Voltage input Frequency Cooling type Weight (kg)
Note 1 : Note 2 : Note 3 : Note 4 : Note 5 :
[HP] [kW] [kVA] Note 2 [A] Note 3

055-2 7.5 5.5 9.1 24

075-7.5 12.2 32

055-4 7.5 5.5 9.1 12

075-7.5 12.2 16
0~400 [Hz] Note 4 3Phases 200~230V Note 5 3Phases 380~460V Note 5 3Phases 200~230 VAC (+10%, -15%) 3Phases 380~460 VAC (+10%, -15%) 50~60 [Hz] (5%) Forced cooling 3.86 4.01 3.86 4.01
The motor capacities were indicated assuming to use 4 poles standard motors. The rated input voltage for 200V is 220V and 400V is 440V. Derating is needed when the carrier frequency is setup over 3kHz. The maximum frequency can not be setup up to 300Hz in case of sensorless vector control. The maximum output voltage does not rise over rated input voltage and the output voltage can be freely set up unless it exceeds the input voltage.

Control

Control type Frequency setup resolution Frequency precision V/F pattern Overload capacity Torque boost Regenerative Maximum brake braking torque Time/ V/F and sensloress vector Digital : 0.01Hz Analog : 0.06Hz (Maximum frequency:60Hz) Digital operation : 0.01% of maximum output frequency Analog operation : 0.1% of maximum output frequency Linear, square, user V/F 150%/1Minute Manual torque boost and auto torque boost 20% Note 1 150% with resistor Note 2

Note 1 : 20% torque regenerative refers to the average braking torque of the motor loss which is generated at deceleration stopping. Note 2 : Please refer to the user manual regarding the braking resistor specification.

Operation

Operation type Frequency setup Operation function Selection among loader, terminal, communication, remote loader operations Digital : Loader Analog : 0~10V, -10~+10V, 0~20mA PID control, up-down operation, 3-wire operation NPN/ PNP selection Function : Forward run, reverse run, emergency stop, fault reset, Jog, multi-step frequency-high, middle, low, multi-step deceleration-high, middle,low, DC braking during stop, second motor selection, frequency increase, frequency decrease, 3-wire run, external trip A/B, changing run pattern from PID to normal operation mode Changing run pattern from the option run to main operation mode, analog frequency fix, Selecting during acceleration/decerelation stop Outputs of the inverter faults or running modes Below DC 24V 50mA Below 1 A (N.O, N.C) AC250V, Below 1A DC30V
P1~P8 Multi function terminal (8points)

Output

Multi function open collector terminal Multifunction relay terminal Analog output
0~10Vdc (Below 10mA) : Selection among frequency, current, voltage, DC voltage

Protective feature

Trip Over voltage, low voltage, over current, ground fault current detection, inverter over-heating, motor over-heating, output overload protection, communication error, output phase open, frequency command loss, hardware fault, cooling fan fault Stall prevention, overload Below 15msec : Runs without stopping yet both input voltage and output should be within rated value Over 15 Msec: Automatic restart
Exterior structure and Environment
Protection Ambient temperature Storage temperature Ambient humidity Altitude, vibration Ambient atmospheric pressure Application site Open type IP20 -10~50 -20~65 Below 90% RH (Non-condensing) Below 1000M or 3,300FT. Below 5.9m/sec2 (0.6G) 70~106 kPa No corrosive gas, combustible gas, oil mist or dust
Alarm Instant power failure

Wiring & Dimension

Wiring

Control terminal

Terminal Function Multi function open-collector output MO common 24V ouput /100mA Multi function input FX : Forward run command RX : Reverse run command (initial setup) Input signal common BX : Emergency stop Multi function input JOG : Jog frequency run (initial setup) RST : Trip release signal Input signal common Multi step frequency-low Multi function input Multi step frequency-middle (initial setup) Multi step frequency-high 10V output terminal for the vloume resistor Voltage signal input for frequency setup : -10~+10V Current signal input for frequency setup : 0~20mA Multi function analog output signal : 0~10V A contact point output B contact point output Contact point common
Multi function relay output
RS485 communication signal connection

Power Terminals

3Phases AC input (Rated input voltage) DB Resistor Commercial line input DB resistor connection Motor connection

Dimension

Inverter Capacity [kW] W [mm] W1[mm] H [mm] H1 [mm] D [mm] [mm] A [mm] B [mm] Weight [Kg] SV055iG5A-2 5.4.4.5 3.86 SV075iG5A-2 7.4.4.5 4.01 SV055iG5A-4 5.4.4.5 3.86 SV075iG5A-4 7.4.4.5 4.01

W A W1 A

H D B W1 B

 

Tags

EL-S752K DPX-510 32VT68N Omni-624 EU KX-TG7170EX K3G21-G Volvo S40 Astra 5000I EX-Z29 5-device Blackberry 7730 Edition CCD-FX410 AV220C2 Maxima-1996 - 1998 MS-194AS DB325 Earth 2150 Series 1-1-0 Masterchef 370 VR-806 Exai8580 FH-P4100R 1200 C DV328AEW XAA CQ-C1123NE Francisco Cd72 Janome 204D E8210 Versatis 620 CA40 Dect KF-50SX200 DVD-SH895M WB1000 Rx-d702 LA37B530p7R NV-F65B - 2000 SRV-3030D R-613 MEX-DV90EE MA-1350-1 NWZ-E455 KA68030A PS-42S4S GS-1524 SGU44E02SK Cronometro 300 3 5 TK-6000 NN-K354 Krups 962 FWG3126 EW962S Review R-26ST XRC5300X NE-1880 Generator Series Qr170 Versatis 670 Touch2 Animal RM-Z250 Software VSX-45TX S50 3D NN-S225mbepg Yamaha QY20 RME ADI2 FSV-M3 Kings DLA-SX21 32PFL7862D 10 Control 1318 NEC Computer Deluxe ML-1640 XEU PS50B550 SF-10 Moov M300 W 101 DWL-2100AP FSM7352S G-III Ql19 LP-R400 Asko W600 DX6000 SS-RXD8S BCD-191NS EL-6930 DC210 KX-TG2357 Bluetooth HUB LS6215-2 PET706

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 