Reviews & Opinions
Independent and trusted. Read before buy Medion Blood Pressure Monitor MD 15231!

Medion Blood Pressure Monitor MD 15231

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Medion Blood Pressure Monitor MD 15231, size: 535 KB
Instruction: After click Download and complete offer, you will get access to list of direct links to websites where you can download this manual.

About

About Medion Blood Pressure Monitor MD 15231
Here you can find all about Medion Blood Pressure Monitor MD 15231 like manual and other informations. For example: review.

Medion Blood Pressure Monitor MD 15231 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Medion Blood Pressure Monitor MD 15231 please write about it to help other people.

 

[ Report abuse or wrong photo | Share your Medion Blood Pressure Monitor MD 15231 photo ]

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 6. Page 1 of 1. Average Rating:
mmxhere 8:58am on Monday, September 13th, 2010 
GREAT RESOLUTION, EVEN BETTER PRICE Purchased this for office use and it looked as good as the name brand monitors we bought in the past. Hanns G computer didplay I think the display is excellent. Colors are bright and sharp. Setup was very easy. But.
monkeyBox 7:10pm on Saturday, September 11th, 2010 
I got this tv since the one I had broke. I had a price limit and wanted a tv fast.
dtweber 2:11am on Friday, June 18th, 2010 
"We bought 2 of these a few months ago and we love them! Image is very clear, easy to adjust, works great for spreadsheets, documents, graphics. "Am very happy with this except the speakers not working but that can be fixed. Monitor size amazed me. "overall I was very pleased with this purchase.Good price,great picture quality,easy hookup.I was disappointed with the sound performance.
cMonty 3:23pm on Sunday, April 25th, 2010 
"We went to the Best Buy in Auburn, Alabama because it was the closest store that listed having this monitor in stock. But getting there.
eonlepapillon 6:34pm on Friday, April 16th, 2010 
If the price is right get the monitors. If not, spring for something that costs a bit more, but is of a better build quality. had a 20 inch CRT, I wanted to buy a 22 inch wide screen monitor but did not want to lose the vertical real estate. Budget allowed for this monitor. Inexpensive, fast. No input lag Limited viewing angles (especially vertically). Color is so so
occe 11:19am on Wednesday, April 7th, 2010 
A Top Shelf Monitor for a Low Shelf Price I purchased this monitor while in the process of building a new computer. No Warranty This worked for a couple of months, then became so noisy you could not remain in the same room with it.

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

Introduction

Congratulations on choosing to buy a health+ product. By doing so you now have the assurance and peace of mind that comes with purchasing a product made by one of Europes leading manufacturers. All products brought to you by health+ are manufactured to the highest standards of performance and safety, and, as part of our philosophy of customer service and satisfaction, are backed by our comprehensive 3 Year Warranty. Please fill in and return the Warranty Card to the address provided.

General information

Please read these operating instructions thoroughly and follow them and the safety notes in particular before using the appliance for the first time! Anything done to or with this appliance may only be undertaken as described in the operating instructions. If you pass on your device to someone else, always include the operating instructions. 5

Safety instructions

This device is not intended to be used by individuals with limited physical, sensory or intellectual abilities or limited experience, and/or a lack of knowledge (including children), unless they are being supervised by an individual responsible for their safety or receive instructions from them concerning how the device must be used. Children should be supervised in order to ensure that they do not play with the device. Keep the device and its accessories out of reach of small children. Keep the packing materials, such as foil away from children. The danger of suffocation could arise in the case of misuse. The device is suitable for healthy adults. Use the unit for comparative measurements, particularly during sporting activities. Do NOT use the unit for medical diagnosis. It can not replace medical intervention. Only start the air supply (ON/OFF button) once the unit is attached correctly. Do not drop the unit and do not place objects on top of it. Never immerse the unit in water. Do not expose it to water or moisture! 6
Do not use the device under extreme temperature conditions! Do not bend the fixed part of the sleeve!
Batteries and Proper Treatment
Batteries may contain combustible materials. By misuse, this may cause battery leakage, heat, explosion or ignition, bringing about injury or damage to the device. Please observe strictly the following matters: The unit is battery-operated. Batteries may endanger life if swallowed. For these reasons, keep the unit out of reach of children. If a battery is swallowed, please obtain immediate medical assistance. Clean the battery and device contacts, if necessary, before inserting batteries. Do not charge batteries (except rechargeable batteries). Do not forcibly discharge batteries. Do not short-circuit batteries. Do not heat or dispose off in fire. Do not disassemble or deform batteries. Your hands and fingers may be injured, or the liquid of the battery may get into your eyes or adhere to your skin. If this happens, rinse with a large quantity of water immediately and consult a doctor. Do not expose batteries to strong impact by dropping or throwing the batteries. 7
Do not reverse the positive (+) and negative (-) terminals to avoid short-circuit. Do not mix used and new or different types of batteries together. Remove the used batteries promptly from the device. Remove the batteries from your device if it is not to be used for a long period. Replace all batteries with new batteries of the same type at the same time.

Disposal

Your device is packaged to protect it against damage during transportation. The packaging is manufactured from materials that can be sent to a specialist recycling facility and disposed of in an environmentally-friendly way. At the end of its life, the appliance must not be disposed of in household rubbish. Do not dispose of used batteries in the household rubbish! They must be deposited at a collection point for used batteries.

Repair

Leave all repairs of your device to authorized and qualified personnel only.
Never try to open and/or repair the unit yourself. Repairs may only be undertaken by our Service Centre or other appropriate specialist workshop.

About this device

Purpose of use
The device is used to measure blood pressure at the wrist. It is suitable for healthy people above 14 years of age and can be used to make comparative measurements especially during sporting activities. The memories are stored in two units, and each unit can store 60 memories at most. This device is only suitable for using in dry, internal rooms. This device is intended for personal use only. It is not intended to commercial use in a heavy industry environment. Use under extreme environmental conditions can result in damage to your device.
If the values obtained give you cause to be concerned about your health, take medical advice. Do not change your treatment/dosage of medication as a result of the values unless you have discussed this with your doctor!

Blood pressure values

When interpreting the values measured, please note that there can be differences in the values measured at the wrist and arm. However, because the values measured at the upper arm and wrist undergoes the same changes the values measured at the wrist can be used for comparative measurements. The blood pressure measurement device displays blood pressure (systolic and diastolic values), pulse, date and time. The following summary can help you to assess the values you measure.
The classification of blood pressure values is based on a definition and classification by the WORLD HEALTH ORGANISATION from 1999. The WHO defines high blood 10
pressure as values above 140 mmHg (systolic value) and 90 mmHg (diastolic value). The new blood pressure classification indicator visually indicates users blood pressure category, Blood pressure classification Low Normal High-Normal Hypertension stage I Hypertension stage II Hypertension stage III systolic mmHg < - -179 > 180 diastolic mmHg < - - 109 > 110 Colourindicator Green Green Green Yellow Orange Red

Overview and Display

1. Colour indicator 2. Battery icon, the battery icon appears if the batteries need to be changed. 3. Time 4. Date (M month; D day) 5. M: Memory button: save measured blood values, set date and time, 6. Power button: Start measurement, confirm date and time setting. 12
1. Memory sign 2. Number of measurement (01 60) 01 last measurement, 02 previous measurement, etc. 3. Blood pressure classification 4. Pulse sign 5. Pulse frequency per minute 6. Diastolic pressure display Display of the memory unit (U1/U2) 7. Systolic pressure display, 8. Irregular heartbeat indication

Getting started

Inserting the batteries
Remove the cover of the battery compartment in the direction of the arrow. Insert two 1.5V batteries size AAA/LR03 (alkaline). Pay attention to the polarity (the negative terminal faces the spring). Close the battery compartment.
Replace the batteries if the battery icon appears on the display, if the display remains blank after pressing the ON/OFF button.
Replace all batteries with new batteries of the same type at the same time. Do not mix used and new or different types of batteries together. Rechargeable batteries are not suitable for the operation of this device.
Setting the date and time
1. Press the buttons and M at the same time. The current month flashes. 2. Press the M button repeatedly to set the current month. 3. Press the button. The day flashes.

4. Press the M button repeatedly to set the current day. 5. Press the button. The hour flashes.
6. Press the M button repeatedly to set the current hour. 7. Press the button. The minutes flash.
8. Press the M button repeatedly to set the current minutes. Date and time have been set. The flashing bar disappears after 10 seconds. 9. Press the button to finish the date and time setting.
The device closes the setting mode automatically after one minute.
1. Attach the wrist sleeve in such a way that it is approx. mm away from the palm of your left hand (see fig. B). Ensure that no articles of clothing are trapped in the sleeve. 2. Hold the lower part of the sleeve as shown in fig. C. Pull down and wrap it around and upwards, so that there is no gap between the sleeve and your wrist. 3. Use your thumb to hold the sleeve cover while you wrap it upwards. 4. Wrap the sleeve according to the shape of your wrist. If the sleeve is not firmly attached the pressure will increase and the wrist will become numb. Correct measurement is then no longer possible. 16
If the sleeve cannot be attached to your left arm and if it is not possible to measure your left arm, use your right one. Attach the sleeve as shown in fig. D.

Correct measurement

Place your elbow on the table or other supporting surface, and hold your arm so that the wrist sleeve is at heart height. In doing so, support your lower arm on the storage box or on a folded towel or similar. To measure your blood pressure, sit comfortably on a chair, take 5 or 6 deep breaths and relax. Always measure your blood pressure at the same time each day! It is important to measure your blood pressure at home and at the same time each day so that the blood pressure, which can change over the course of a day, is recorded properly. 18
Inform your doctor of the values measured so that he can give you medical advice. Blood pressure measured at the wrist can vary from that measured at the upper arm. The values may be slightly different because of the different measurement positions and the strength of the blood vessels in the wrist and upper arm. In many cases, the difference for healthy people can be 10 mmHg of the systolic and diastolic blood pressure.

Attention is advised for the following types of person: People with high blood pressure, diabetes, liver disease, hardened arteries, poor circulation.
Carrying out measurements
1. Attach the wrist sleeve to your wrist as described above. 2. Press the button. All indicators are displayed for a few seconds on the screen; then the screen shows the time and the most recently selected memory unit (U1/U2). 3. You can modify the current memory unit by pressing the button M. If you have already stored measurements in this unit the display shows the latest values.
During measurement do not move the sleeve or your arm or hand muscles.
A few seconds later the monitor starts searching the zero point. When the air pressure is stable the monitor begins to measure automatically. 4. If you want to stop the measurement, press the button. The air is released from the sleeve.
If you want to repeat a measurement you should wait at least five minutes. The air must be completely removed from the sleeve.

Automatic Measurement

Measurement starts automatically; the device pumps up the sleeve. If the sleeve pressure is too low the device pauses and pumps up the sleeve again until it reaches a sleeve pressure that is appropriate for the measurement. The device also measures your pulse. The value displayed will fall during measurement. The sleeve deflates when the measurement is complete. The systolic and diastolic blood pressure and the pulse with the pulse icon appear in the display.
Indication of an irregular heartbeat (arrhythmia)
The pulse normally beats evenly (rhythmically). The symbol will appear in the display if the device perceives irregularities in the rhythm of the pulse. Repeat the measurement in this case. There can be different causes of irregularities in the rhythm of the pulse. Please consult your doctor if your pulse is arrhythmic in the long term.

Memory unit

Reading the stored values
The device has two memory units U1 and U2. Up to 60 measurements can be saved in each unit. You can also display the average values of the saved measurements.
1. The device should not be in measure mode. Switch it off if necessary. 2. Press the button M to enter the memory mode. On the display appear the memory sign, the memory unit and the number of measurements, which have been stored in this unit.

3. You can modify the current memory unit by pressing the

button.

4. Press the button M to display the stored values. 5. The measured values are displayed in reverse order. With each press of the button M the previous results appear.
6. Press the button to exit the memory.
The saved values remain saved when the device is switched of with the button.

Deleting memory

1. Press the button M to enter the memory mode. On the display appear the memory sign, the memory unit and the number of measurements, which have been stored in this unit. 2. Select the memory unit you want to delete by pressing button. the 3. Press the button M for more than 2 seconds. A control tone signalizes the deletion. On the display appear two bars. The values of the selected memory unit are deleted.

Cleaning and maintenance

Notes on maintenance
It is recommended that you check the usability of the unit every three years.

Cleaning and storage

Clean the device with a soft, lint-free cloth. Do not use any solvents, corrosive or gaseous cleaning agents. Store and transport the device in the storage box supplied. Do not bend the preshaped sleeve outwards. The sleeve should neither be washed nor dry cleaned. If the appliance is not going to be used for long periods, remove the batteries.

Error messages

Defect Possible cause and solution The batteries are dead
Replace both batteries with 2 new 1.5V, LR03/ AAA batteries Take the measurement again. Dont move and dont speak during the measurement.

Er 1 Er 2 Er 3

Pressure system is unstable before measurement Systolic pressure detect fail Diastolic pressure detect fail Pneumatic system blocked or cuff is too tight during inflation. Pneumatic system leakage or cuff is too loose during inflation
Place the cuff correctly and try again.

Defect Er 5 Er 6

Possible cause and solution Inflation above 300 mmHg Over 3 minutes while pressure above 15 mmHg EEPROM accessing error Device parameter check error MCU self-verity error Span error Take the measurement again after a 5 minute break. Contact the service centre if the error is indicated repeatedly over a long period of time.

Er 7 Er 8 Er 9 Er A

If you detect failures on the display or wrong measurements, remove the batteries and replace them after 1 minute.

Technical Data

Measurement method: oscillometric Measuring range: Power supply: Display: Memory space: Pressure built up: Air release: Measuring accuracy
Blood pressure: 30 ~ 250 mmHg Pulse: 40 ~ 180 beats/min. 2 x 1.5 V batteries size LR03/AAA (alkaline) LCD 2 x 60 measurement results automatically by pump automatically via one-way valve +/- 3 mmHg pressure indicator
Operating temperature: +5 ~ +40 C air humidity < 80 % Storage temperature: Weight: Sleeve size: -20 ~ +55 C, air humidity < 95 % ca. 108 g (excluding batteries) 14 ~ 19.5 cm
Subject to technical changes.
The product meets the requirements of the guideline 93/42/EWG for medical devices. The device corresponds with standards EN 1060-1: 1995 and EN 1060-3: 1997 for non-invasive blood pressure measuring devices. Type B The device was manufactured in 2008.
The serial number is arranged inside the battery compartment.

Appendix

Table 201
Guidelines and manufacturer's declaration electromagnetic emissions
Model MD 15231 is designed for operation in an environment as described below: The customer or user of Model MD 15231 should ensure that it is operated in such an environment.
In line Interference with emission measurements HF emissions according to CISPR 11 Group 1
Electromagnetic environment guidelines Model MD 15231 uses HF energy exclusively for its internal operation. Therefore its HF emission is very low and it is unlikely that nearby electronic devices should suffer interference.
Interference emission measurements

In line with

Electromagnetic environment guidelines
HF emissions according to CISPR 11

Class B

Emission of harmonics according to IEC 61000-3-2 Emission of voltage fluctuations/flicker according to IEC 61000-3-3

Not applicable

Model MD 15231 is intended for use in all premises including residential areas and those that are directly connected to public supply networks that also supply buildings that are used for residential purposes.
Table 202 Guidelines and manufacturer's declaration electromagnetic interference immunity
Model MD 15231 is intended for operation in an electromagnetic environment as described below: The customer or user of Model MD 15231 should ensure that it is operated in such an environment

Interference immunity tests

IEC 60601test level

Pass level
Electrostatic discharge (ESD) according to IEC 61000-4-2
6 kV contact discharge 8 kV air discharge
N 8 kV Floors should be of wood or Air discharge concrete or laid with ceramic tiles. If the floor is covered with synthetic material, the relative humidity should be at least 30%. Not applicable The quality of the power supply should match that of a typical business or hospital environment.
Fast, transient electrical interference/ bursts according to IEC 61000-4-4 Voltage surges according to IEC 61000-4-5
2 kV for supply lines 1 kV for input and output lines 1 kV bipolar voltage 2 kV unipolar voltage
The quality of the power supply should match that of a typical business or hospital environment.
Voltage dropouts, shortterm breaks and drops in supply voltage according to IEC 61000-411
< 5 % UT 1) 40 % UT 2) 70 % UT 3) < 5 % UT 4)
The quality of the power supply should match that of a typical business or hospital environment. If the user of Model MD 15231 requires continued operation even if power supply drop-outs occur, we recommend supplying Model MD 15231 from an uninterruptible power supply or a battery. Magnetic fields at the mains frequency should match the typical values found in business or hospital environments.
3 A/m Magnetic field at the power frequency (50/60 Hz) according to IEC 61000-4-8
Note: VT is the main AC voltage befor application of the test level. 1) (> 95 % drop in VT) for period 2) (60 % drop in V T) for 5 periods 3) (30 % drop in VT) for 25 periods 4) (> 95 % drop in VT) for 5 s
Table 204 Guidelines and manufacturer's declaration electromagnetic stability
Model MD 15231 is designed for operation in an electromagnetic environment as described below: The customer or user of Model MD 15231 should ensure that it is operated in such an environment. Electromagnetic environment guidelines Portable and mobile should not be used closer to the [appliance or system] than the protection distance calculated using the equation applicable for the emission frequency.
Recommended protection distance:
Conducted HF interference according to IEC 61000-4-6 Radiated HF interference according to IEC 61000-4-3

3 Veff 150 kHz to 80 MHz

3 Veff

d = 1,17 1/V *

3 V/m 80 MHz to 2,5 GHz
d = 1,17 m/V * 80 MHz to 800 MHz
d = 2,33 m/V * 800 MHz to 2,5 GHz
Where P is the transmitter's nominal output in Watt (W) according to the information provided by the manufacturer of the transmitter and d is the recommended protection distance in metres (m). The field strength at all frequencies of stationary transmitters is, according to an on-site inspection a, below the pass level b. Interference may be experienced in the vicinity of appliances marked with the following symbol
NOTE 1: The higher applies at 80 MHz and 800 MHz. NOTE 2: These guidelines may not apply to all situations. The radiation of electromagnetic waves is influenced by absorption and reflection from buildings, objects and people.
The field strength of stationary transmitters, such as base stations for radio telephones and terrestrial mobile services, amateur stations, AM and FM radio and television transmitters cannot be determined precisely in theoretical terms. In order to determine the electromagnetic environment resulting from stationary HF transmitters we recommend an on-site inspection. If the field determined at the location of Model MD 15231 exceeds the pass level stated above the Model MD 15231 must be checked for normal operation at each point of use. If unusual performance characteristics are observed, it may be necessary to undertake additional measures such as realigning or moving Model MD 15231. Not applicable in the frequency range from 150 kHz to 80 MHz.

Table 206

Recommended protective distances between portable and mobile HF telecommunication devices and the [DEVICE or SYSTEM] Model MD 15231 is intended for operation in an electromagnetic environment in which the HF interference is controlled. The customer or user of Model MD 15231 can help to avoid electromagnetic interference by adhering to the minimum distance between portable and mobile HF telecommunication devices (transmitters) and the Model MD 15231 depending on the output of the communication device as shown below.
Nominal output of transmitter W
Protective distance depending on the transmission frequency m 150 kHz to 80 MHz 150 kHz to 80 MHz outside the ISM bands within the ISM bands N/A N/A N/A N/A N/A 80 MHz to 800 MHz d = 1.2 0.12 0.38 1.2 3.800 MHz to 2.5 GHz d = 2.3 0.23 0.73 2.3 7.3 23

0.01 0.10 100

N/A N/A N/A N/A N/A
For transmitters whose nominal output is not listed in the above table, the distance can be determined using the equation in the relevant column, where P is the transmitter's maximum nominal output in Watt (W) as specified in the information provided by the transmitter's manufacturer. NOTE 1 The higher frequency range applies at 80 MHz and 800 MHz. NOTE 2 The ISM frequency bands (for industrial, scientific and medical applications) between 150 kHz and 80 MHz are 6.765 MHz to 6.795 MHz; 13.553 MHz to 13.567 MHz; 26.957 MHz to 27.283 MHz and 40.66 MHz to 40.70 MHz. NOTE 3 The pass levels in the ISM frequency bands between 150 kHz and 80 MHz and in the frequency range from 80 MHz and 2.5 GHz are intended to reduce the probability that mobile/portable communication devices might cause interference if they are accidentally brought into the patient area. For this reason the additional 10/3 factor is applied when calculating the recommended protection distances in these frequency ranges. NOTE 4 These guidelines may not apply to all situations. The radiation of electromagnetic waves is influenced by absorption and reflection from buildings, objects and people.

 

Tags

CDX-GT150 HF850 LV2398 PA-80 GR-SXM740u-gr-sxm740 12-180 Audi 100 HD203WI Hdctm300 Setup Assist Z098 CVP-209-CVP-207 D-BG1 Yamaha DD-7 HL-1260E EMP-503 Of Iron KP-XA43m61 Sli GR Memoire Cs3 Fse 450 Zyxel P334 37LC2D 4 0 P4AL-800 LF-U850D CQ-RDP151N OM-4TI MW83Y Combo HS2005 LP-7500 CE7140 725MP SGH-X560L CD713 Digimax V50 DDX5022Y FZR600L LVS563 Fdrv-90E IC-751A Aqxxf 121 2 4 Strv55 Spirit-10A Academy AS301 DXS-3350SR RAS18CH1 3600 Plus STU1130-00G Airtronics M11X KDC-7024 Deskjet 920C Cube-60D HF-33W GZ-MG130 Review DX 450 Elux NOR DVP-LS785V LC-20S1E Plus 2488R FC9170 PI 2550 QW288T Gloss 650 IE Astra OPC Strategy LE32A431t2 Z1000 Wd-52825 Dect6800 ZHC600X RX-7010R Omnibook XE3 DS-12CS NV-GS80EP FX-2190 Hp 300 ONE XL 1 1 NN-A860WB Fishfinder Aficio 1022 EZ-150 Ep552HA ICC17 HAP 240 Indoor RTS CDP-XA555ES Way Plus HB401 P4B266-E Catcher UE40C5100QW AWT1235AA

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 