Minolta CM3600D
About Minolta CM3600DHere you can find all about Minolta CM3600D like manual and other informations. For example: review.
Minolta CM3600D manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Minolta CM3600D please write about it to help other people. [ Report abuse or wrong photo | Share your Minolta CM3600D photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Minolta CM3600D - Brochure, size: 1.6 MB |
Minolta CM3600D
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

Built for Precision, Priced for Economy
New Enhanced Performance Technology teams patented performance features with simplified design and advanced cost-reducing manufacturing techniques.
The result: n A highly accurate, reliable, rugged spectrophotometer. n Versatile enough for all colorimetric applications. n Simplified operation. And n LOW PRICE
Technology
KONICA MINOLTA Innovative Optical System "World first" technology : n Numerical Gloss Control measurement within a few seconds. n Numerical UV Control for calibration and measurements. n Soft-flash mode to avoid triplet adsorption in fluorescent materials.
The Innovative CM-3600d Spectrophotometer Brings You Highest Quality Levels in Color Measurement along with Unsurpassed Versatility, User Comfort and Low Cost!
Enhanced Performance Technology Konica Minolta Innovative Optical System
The CM-3600d is equipped with Minolta Innovative Optical System technology. For users, this means high accuracy and repeatability, improved performance, additional features, simple operation, and - low, affordable pricing. This technology also provides:
Performance
Fast, simultaneous measurement of Specular Included and Specular Excluded components (SCI/SCE) Fast, Instantaneous numerical UV adjustment enables UV-included, UV-excluded, and UV-adjusted data to be obtained simultaneously Precise inter-instrument agreement. All CM-3600d's meet published inter-instrument agreement.
Full range of application coverage
Whatever your sample looks like, with the CM-3600d you can measure it! Reflectance of opaque samples, Transmittance of transparent liquids or solids and Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is truly versatile.
Versatility
Full wavelength range 360-740nm with 10nm pitch Large (6") sphere; d/8 geometry Reflectance and transmittance sample measurements Changeable measurement areas (4mm,8mm,or 25.4mm) View finder design for easy sample viewing Compact and lightweight
For high-accuracy color control The newly designed Monolith Polychromator Unit
consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array.
1.Numerical Gloss Control
Instead of using a mechanically driven gloss trap, the CM-3600d is equipped with a patented numerical Gloss (SCl/SCE) control system. By sequentially firing two flashes, within a few seconds the system provides both SCI and SCE values for each sample. SCI specular component included SCE specular component excluded
Reliability
High reliability design with fewest moving parts of any benchtop spectrophotometer
Transmittance Measurement-The CM-3600d employs the d/0 geometry (diffused lighting, 0 viewing), which conforms to ISO, DIN, CIE, and ASTM standards.
Reflectance Measurement-The CM-3600d employs d/8 geometry (diffused lighting, 8 from normal viewing) which conforms to JlS, ISO, DIN, CIE and ASTM standards.
SpectraMagic NX
(Optional)
Supports Windows2000/XP
Konica Minolta Innovative Optical System Technology
Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before.
Multiple measurement area selection Bright and clear sample viewing system
The retro mirror's reflected and illuminated sample viewing screen minimizes fatigue and allows trouble-free sample observation. To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25.4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens.
2.Numerical UV Control
To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, never seen before: The measured values of two sequentially fired flashes, one with full UV energy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UVactivated fluorescence sample. To avoid triplet effect on FWA treated samples, the CM-3600d can be set to Soft-Flash mode. Numerical UV Control technology makes faster, more effective and reliable measurements of FWA treated materials such as textiles, papers and detergents.
LAV 25.4mm
MAV 8mm
SAV 4mm
Compact but yet Powerful Designed to meet your highest ergonomic expectations
The compact and space-saving body as well as all functions of the CM-3600d have been designed to ensure easy and fatigue-free operation in daily use. The bright mirror sample viewing system, the sample holder for up to A4 size samples with full 90 lock down, and the versatile Transmittance chamber for liquid or translucent samples are all just where you expect them to be for easy operation. Behind the compact and spacesaving design, you'll find the skills of a top-class instrument with 6" large sphere and other functions so far only found in much larger and more expensive instruments.
SpectraMagic NX enables you to perform comprehensive color inspection and analysis of incoming raw materials, in process production, and outbound color critical goods and materials in virtually any industry. With SpectraMagic NX you can insert digital images with measured data. Measure samples in any of 8 universally accepted color spaces. Select from 15 illuminants, and up to 40 indices to determine specific color and appearance properties, such as strength, brightness, haze, yellowness, opacity and strength. You can even configure up to 3 customized color equations. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagic NX comes with predefined templates using skin technology, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's well known and respected Precise Color Communication. Step by step navigation help. SpectraMagic NX conforms to FDA 21 CFR Part 11 assuring integrity and reliability of data records. Windows is a trademark of Microsoft Corporation in the USA and other countries.
TM TM TM TM
Dimensions
(Units:mm)
Maintenance free technology and ruggedness concept
The CM-3600d is equipped with maintenance-free technology and solid state components to withstand rugged conditions. The monolith polychromator unit assures highest durability and stability. With one exception (Observing Lens), the CM-3600d does not use any moving parts. Furthermore, each CM-3600d passes a hard endurance test program to comply with KONICA MlNOLTA's highest quality standards in accordance with ISO-9001.
POWER ON OFF
UV-adjusted data
208 17
System Diagram
Cell CM-A97 (2mm)
Cell CM-A98 (10mm)
Cell CM-A99 (20mm)
Plastic Cell Plastic Cell Plastic Cell CM-A130 CM-A131 CM-A132 (2mm; set for 100) (10mm; set for 100) (20mm; set for 100)
Personal Computer RS-232C Cable IF-A12 (for IBM PC)
RS-232C Cables IF-A13 to IF-A15 Target Mask CM-A107 ( 4mm) Transmittance Specimen Holder CM-A96
Transmittance. Zero Calibration Plate CM-A100
Target Mask CM-A106 ( 8mm)
Unit Driver CM-A108 AC Adapter AC-A12 AC Adapter AC-A21 (for Korea)
SpectraMagic NX CM-S100w
Spectrophotometer CM-3600d
Target Mask CM-A105 ( 25.4mm)
(with floppy disk containing calibration data)
White Calibration Plate CM-A103
Standard accessories
Optional accessories
Zero Calibration Box CM-A104
Dust Cover CM-A110
Accessory Case CM-A109
Color Tiles
Specifications
Illumination/ observation system Reflectance;d/8 (diffused illumination, 8-degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded) Conforms to CIE No.15,lSO7724/1,ASTME1164, DIN5033 Teil7 and JIS Z8722 condition C standard. Transmittance : d/0 (diffused illumination, 0degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033 Teil7 standard. Silicon photodiode array (dual 40 elements) Diffraction grating 360 to 740nm 10nm Approx.10nm 0 to 200%; resolution: 0.01% 152mm Pulsed xenon lamps (X4) Approx. 1.5 seconds Approx. 4 seconds;when SCI/SCE measured
Network construction for color control either within an organization or between organizations
High inter-instrument agreement between the same Konica Minolta model and also among all CM models (benchtops and portables): CM-2000 series, CM-3000 series, This inter-instrument agreement is ideal when multiple units will be used for color control either within an organization or between organizations.
CM-3700d
Light-receiving element Spectral separation device Wavelength range Wavelength pitch HaIf bandwidth Reflectance range Sphere size Light source Measurement time Minimum interval between measurements Measurement/ illumination area
CM-3500d
LAV : 25.4mm/30mm MAV: 8mm/11mm (Selectable) SAV : 4mm/7mm Repeatability Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within E*ab0.02 Inter instrument Mean E*ab0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles agreement compared to values measured with master body. Temperature Spectral reflectance: Within 0.10%/C dependence Color difference: Within E*ab 0.05/C UV adjustment Instantaneous numerical adjustment UV cut filter 400nm cutoff and 420nm cutoff Transmittance Width: 133mm; depth: approx. 50mm; measurement dia.: approx. 17mm chamber Transmission sample holder (Optional accessory): Sample holder; for both plate-shaped and liquid samples (removable) Interface RS-232C, D-SUB 9-pin (female) terminal Power AC120V/230V 50/60Hz (Using included AC adapter) Operating temperature/ 13 to 33C, relative humidity 80% or less (at 33C) with no condensation humidity range (*1) Storage temperature/ 0 to 40C, relative humidity 80% or less (at 33C) with no condensation humidity range Size (W x H x D)/weight 244 x 208 x 378 mm(9-5/8 x 8-3/16 x 14-7/8 inch),12 kg(26-7/16 lb.) Standard accessories White Calibration Plate,Target Mask (4mm) ,Target Mask (8mm) ,Target Mask (25.4mm) , Zero Calibration box, AC adapter, Dust Cover, Accessory Case, Unit Driver, RS-232C Cable (9-pin,2m) Options SpectraMagic NX(software) ,Transmittance Specimen Holder, Cell (2mm) / (10mm) / (20mm), Transmittance Zero Calibration Plate, RS-232C Cable (IBM,PC/AT 5m) / (IBM,PS/2 2m) / (IBM,PS/2 5m)
R&D
Company A
Design
CM-3600d
Production
CM-2000 2600d 2500c series 2500d
In-house color control
Company B
Color control between companies
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series CM-3600d CM-3500d CM-2600d/2500d/2500c "State of the Art" Reference models Laboratory and Production modell Unique Top Port bench-top model Top class accuracy portables
*1 Operating temperature/humidity range of products for North America : 13 to 33C, relative humidity 80% or less (at 31C) with no condensation
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Certificate No : YKA 0937154 Registration Date : March 3, 1995
Certificate No : JQA-E-80027 Registration Date : March 12, 1997
1998 KONICA MINOLTA SENSING, INC.
9242-4868-11 AGMFPK 15
Printed in Japan
Tags
19LH2000 CF-21D30 EMP-730 LN46B610a5F Awis12P 21j1-RU Install DVD-S25 AR-F151 IP1500 Supra 522 C UE-40C7000 EDE419M EL-6920 RMR616HGA Pro PCI Niva 1600 DB245 Motorola C650 W12THM-cb60 PV-L779D Lecoaspira 700 DFH755 Compressors RK Globalmap 100 Programchart R-880B S Gate Yamaha C-6 6100A DHG525 8080 PC Optio E60 Canon ZR60 Polyglass TX710W XV-Z9000U P4C800 28PW8504-12 HI-MD Motorola K1 Deville 1994 A 50 TS380 Colibri 25 NX-8E 5720G KDL-40HX803 CMT-DF1 12 0 Siemens Vibe ERB34003W8 RS27klmr Premier 816 Review XRC450 GH688 Live Plus TDP-S8 KS 54 MB-4384B EW558F TTR90-2000 RT-44NA43RP CF-371T RM-L1AM R1043 5-DRS TXL32G20B CU-HE9GKE NON-stop Girl Model 1680 Tecra M5 Acerpower 1000 7050B VK540E-2001 Motorola I880 PSS120 Connect Mf4120 Duoset H141 DVX352 X700HNA Universalis N620C DSC-P31 VGN-A115M Apx900 GP1 250I HVR-2250 SCX-4824HN M3400 Guitarfx RDR-HX950 Yamaha HS8 HB851 PV-GS39 EOS-1DS Gig III CM1629
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding