NOVA CONTROLS
PRO-FLOW
Dispenser & Remote Programmer
Prevent BIG Drain Problems with the little dispenser from Hydro NOVA Pro-Flow is a compact, easy-to-use dispenser of natural enzyme chemistries that dissolve grease, food and other organic matter in drains and pipes. Pro-Flow automatically dispenses product based on preset formulas and does not need user action to start or stop operation. Pro-Flow is programmed at installation, via the installers hand-held Remote Programmer. The remote is designed to program one or multiple units, with point-and-click ease. Rather than repeatedly entering similar formulas into each customers dispenser, three formulas are stored in the remotes memory and beamed via infrared (IR) technology to the chosen dispenser. By combining easy dispenser installation with point-and-click programming, the Pro-Flow keeps drains operating efciently, thereby: Avoiding Costly Rooter Cleanings Eliminating Odor and Reducing the Need for Odor-Control Technologies Pro-Flow Dispenser with Wall Transformer and Handheld IR Remote Programmer Using Safe, Natural Enzymes Instead of Harsh, Alkaline Chemicals
Features
Remote Programming All programming, time settings and operational status information is beamed between the installers handheld remote programmer and the Pro-Flow, with point -and-click ease. Cost Effective Simple installation, and the Remote Programmers enter once, program many feature, means lower installed and total cost over the life of each unitand less installation time. Easy to Mount Mounts in just minutes with either peel and stick hook-and-loop fasteners or wall anchors & screws. No User Training Required The Pro-Flow operates automatically, throughout the week, using pre-programmed formulas. The dispenser has no operating buttons or specic language requirements. No need for the customer to turn the Pro-Flow on or off! Two LEDs indicate low battery and power-on status. Compact Size A Pro-Flow dispenser has the footprint of a 3 x 5 index card and doesnt need to be within reach. This makes Pro-Flow ideal for those small, hard-to-get-to spotsunder a sink, high on a wall, or mounted on an out-of the-way product container. Language Neutral Dispenser The Pro-Flow operates consistently, regardless of the users native language. Two LEDs are clearly labeled with universal icons to indicate low-battery and power-on. Choice of Installation Congurations No need to be near a power outlet. You can use either a wall transformer or battery box to power Pro-Flow. Mount it on a wall, on the side of a machine, or on our custom product container lid.
Installation & Operation Guidelines
Install Pro-Flow indoors on a vertical surface or product container lid. After installation, the customer experiences hands-free dispensing and can view two LEDs with universal icons for POWER-ON and LOW BATTERY. After setting the Remote Programmers current day and time, choose either the factory pre-set formula (3 oz./Midnight/Every Day) or modify it to suit your customers needs. A built-in battery backup maintains the 24-hour clock and up to three programmed formulas regardless of whether the remote is powered ON or OFF. During service calls, beam a formula to any Pro-Flow dispenser and/or check the dispensers battery life and currently used program with the press of a button. At installation (or after product container changes) press the prime button on either the remote or the dispenser for uninterrupted product supply.
Pro-Flow Dispenser w/ Battery Pack
Specication
Size5.18 W x 3.5 H x 1.9 D 13.2cm W x 8.9cm H x 4.8cm D Weight5.6 lbs. (159g) Electrical100-240 VAC, 50-60 Hz, 1 A Total Amp. draw during operation400 mA Pump Flow Rate 6 oz./min. 180-200 ml/min.
Ordering Information
Pro-Flow Dispenser with Product Container Lid and Battery Pack
Model P/N 00-08100-110 P/N 00-08105-1100 P/N 55-08095-00 P/N 08110-110 Description Pro-Flow Dispenser with Battery Pack Pro-Flow Dispenser with Wall Transformer, 115 VAC, 60Hz Handheld IR Remote Programmer Pro-Flow Dispenser with Product Container Lid and Battery Pack
LIMITED WARRANTY This unit is warranted against defects in materials and workmanship for a period of one year from the date of delivery and covers all parts of the unit except the elastomer pump tubing. Any units which prove to be defective within the warranty period will be repaired or replaced when returned to the factory, freight prepaid. No other warranty is expressed or implied. Equipment abuse or misuse voids warranty. Warranty does not cover any consequential liability resulting from the performance of the equipment.
Pro-Flow Dispenser with Wall Transformer
225 Westridge Drive, Watsonville, California, USA 95076-4168 Web: www.novacontrols.com 831.786.1470 800-252-NOVA (6682) Fax: 831.786.1650 Customer Service Fax: 831-786-1652 e-mail: sales@novacontrols.com
N OVA C O N T R O L S
L E A D I N G T H E W A Y
SystemsCompany
TOTAL ECLIPSE PRO Quick Start Guide
for the TOTAL ECLIPSE CHEMICAL MANAGEMENT SYSTEM
The TOTAL ECLIPSE PRO Controller is an integral part of the TOTAL ECLIPSE Chemical Management System, that also includes: The Machine Interface Accepts washer signals and converts them to safe, low-voltage inputs. The Pump Module Provides product transfer to the wash machine. The TOTAL ECLIPSE PRO Controller is compatible with any Nova Controls modular pumpstand. including the Eclipse, Orion or any of the Large Laundry dispensers. The Flush Manifold (optional) Available for water flush chemical transfer applications. Designed for maximum versatility in OPL or large laundry machines, the TOTAL ECLIPSE PRO Controllers selectable Operating Modes allow the system to work with trigger signals from fully-programmable washers or with manually triggered signals (or cycle time extenders) from non-programmable, fixed-time washers. The Controllers easy-to-understand, plain-text LCD display (available in a variety of languages), make operator training simple. Installation time and cost is significantly reduced with the computer based Formula Editor program, allowing an off-site technician to create sets of up to 20 industry-specific, efficient and cost-effective formulas that are loaded onto a controller with a customer-supplied USB flash drive (16 GB or smaller). Summary Reports can be saved to the same USB flash drive, providing usage and programming information to effectively analyze and manage each machine. Components Supplied
TOTAL ECLIPSE PRO Controller (P/N 01-09140-00, Grey/Teal) (P/N 01-09150-00, Black/Red)
Wall Mount Bracket, Kit (P/N 13-08462-00, Grey) (P/N 13-08916-00, Black)
Quick Start Guide (P/N 20-09130-00)
DOWNLOAD from the Nova Controls website (http://www.novacontrols.com):
Formula Editor Software for Windows 2000/XP/Vista, Linux & Mac OS 10.4 (Minimum requirements: Java JRE 1.5 or higher [90 MB disc space]; 1024 x 768 screen resolution; 128 MB RAM; 10 MB disc space; USB 2.0 and a USB flash drive [16 GB or smaller] for data transfer to TOTAL ECLIPSE PRO controller) Additional Language Files Two Types (for Formula Editor Software and for TOTAL ECLIPSE PRO Controller Menus TOTAL ECLIPSE PRO Reference Manual at www.novacontrols.com/instructions.htm (P/N 20-09120-00) How to Use the TOTAL ECLIPSE PRO Quick Start Guide
Use this Quick Start Guide if you are already familiar with installing and using dispensing systems. Please refer to the TOTAL ECLIPSE PRO Reference Manual for detailed instructions, including information on the optional Relay, Event, Occurrence and Group Operating Modes. Refer also to the Installation and Operations manual that is included with your pumpstand or upgrade kit for additional instructions.
TOTAL ECLIPSE PRO Controller Specifications
Size Weight Power Rating Data Input Field Size Pump Capacity Environmental Temperature Humidity Indoor Installation Altitude 5.2" W x 4.5" H x 2.5" D ( 13.2 cm W x 11.4 cm H x 6.4 cm D) 0.65 lb. (0.30 kg) SELV Power source is pumpstand 15 characters maximum input for custom names 99.99 oz. (2999 ml.) 8 pump (with 3 amount settings per pump) maximum IP Rating 44 Pollution Category 2 Installation Category II 10 to 49 C (50 to 120 F) maximum 95% relative humidity, maximum Approved for indoor use only. Must not be installed outdoors. Install at or below 6,500 ft. (2000 m) maximum
IMPORTANT NOTE: Quick Start instructions assume that Formula/Setup files will be loaded via a USB Specifications subject to change without notice. flash drive, which may override the following factory default settings: Standard Operation; Eclipse Flush P.I.; Flush Time0 sec.; Cycle Time90 min.; Signal Filter Time2 sec.; User Prime Disabled; Bleach DefeatOff; Units of Measure = SAE. Default Passwords are Installer = 01234; Manager = 0123. It is recommended that default passwords are changed via the controllers keypad (and noted) after installation and system setup are complete. To change formulas, settings or passwords using controller keys, or to add a machine or company name, see the Guide to Keypad and Menus (p. 5) and Initial Setup on Installer Menus (p. 6).
P/N 20-09130-00A Copyright 2008 Nova Controls, Inc. 1
Installation
WARNING Disconnect all power to the pumpstand during installation, service, and/or any time pump cabinet is opened. The TOTAL ECLIPSE PRO should be installed by a qualified technician only, in accordance with all applicable electrical and plumbing codes. Desconecte toda la corriente elctrica al dosificador durante la instalacin, servicio y / o siempre que se abra el gabinete de la bomba. El equipo TOTAL ECLIPSE PRO debe ser instalado slo por tcnicos calificados y de acuerdo con todas las normas de plomera y elctricas que apliquen.
ADVERTENCIA
Step 1. Install the Machine Interface (MI)
WARNING Keep MI and communication cable away from high voltage wires and relays. NEVER parallel the cable with high voltage lines. Mantenga M.I. y los cables de comunicacin separados de los cables de alta tensin y rels. NUNCA instale el cable paralelo con las lneas de alta tensin.
1. Route MI signal wires through 1/2 inch knock-out on washer (within the wiring area). MACHINE INTERFACE (Front) (Rear) Secure MI to washer with lock nut (provided). J2 Signal Cable Wires 2. Plug J2 cable into MI. Bundle excess J2 cable outside washer and connect other end Connection to J2 connector on rear of Controller. 3. Connect J1 cable from pump module to J1 connector on Controller. The maximum distance for a J1 cable is 75 ft. (22.9 m.) unless using a break out box and hard wiring. Contact Nova Controls for additional cables, a coupler or detailed instructions. TOTAL ECLIPSE PRO Controller (Rear) 4. Secure J1 and J2 cables to controller tie-down posts with tie wraps. J2 Cable J1 Cable Step 2. Connect Signal Wires
Voltage
Tie Wraps
The Machine Interface will work with any signal voltage between 24 240VAC or 22 24VDC. With DC signals, polarity must be observed. Common is negative. The signals should be positive voltages.
CAUTION CUIDADO Always verify all voltage sources with a meter. Electrical wiring connections for supply triggers are to be done inside the junction box. Siempre verifique la alimentacin de corriente con un voltmetro. Las conexiones elctricas a los disparadores de suministro (supply) deben hacerse dentro del recinto donde se encuentran los suministros (supply). Supply Signal Black wire Brown wire Red wire Orange wire Yellow wire Signal Common White/Black White/Brown White/Red White/Orange White/Yellow Connect to: Standard (US) Group (EU) Pump 1 Pump 2 Pump 3 Pump 4 Pump 5 Group 1 Group 1 Group 2 Group 2 Group 3
Supply Trigger Wiring
Identify the washer supply signals. In Standard or Group Mode of Operation, use appropriate terminal connectors to connect the signal wires to the Machine Interface wires, per table at right. (Do not use this table for Event or Occurrence Modes; see Manual.)
Trigger Signal Wiring Notes:
Trigger Signal 1 Signal 2 Signal 3 Signal 4 Signal 5
If one or more pump signals are not used, they Signal 6 Blue wire White/Blue Pump 6 Group 4 do not need to be connected. If you are triggering more than one pump from a single signal, connect all MI signal wires for those pumps to that signal. Wire nut unused wires. If washer has a single common, wire nut all commons together. Step 3. Mount the Controller 1. Mount bracket with velcro-style strips, according the directions at right. Install wall board screws or nuts and allen bolts, if needed. 2. Slide controller down onto mounting bracket until it snaps in place. 3. Install pump module and make all electrical and plumbing connections for the system, but do not apply power to the TOTAL ECLIPSE PRO until you are ready to select a language of operation.
Controller Language Options
1 Attach Velcro-style Strips and Mount 2 (Optional) Install Wall Board Screws or Masonry Nuts & Allen Bolts Mounting Bracket 3 With J1 and J2 cables connected, slide Controller onto mounting bracket until it snaps into place.
Each TOTAL ECLIPSE PRO is shipped with two languages installed: English/Spanish (Americas); English/German (EU); or English/Simple Chinese (Asia). Additional languages may be downloaded from the Nova website directly to your USB flash drive (16 GB or smaller). If changing from a default languages, you will need your language-enabled USB flash drive for the next step.
2 P/N 20-09130-00A
Step 4. Select the Controller Menu Language EXIT UP ENTER 1. Apply power to pumpstand & power-up Controller. Two available LANGUAGES are displayed. (Optional) To replace the non-English language, connect a USB flash drive with LEFT RIGHT the new language to the controllers USB port (under flap on right side of controller). 2. Move the selection box by using the UP or DOWN ARROWS until the correct DOWN language is contained within the box. TOTAL ECLIPSE PRO Keypad (Press & Hold=Auto-Key Repeat) 3. Press Enter to select a language. All menu and application items are translated into the new language. Text input by the installer (pump and formula name, etc.) remains in the original language and is not translated. Step 5. Set the Current Date and Time 1. After the language is set, the DATE & TIME menu appears as YYYY-MM-DD (Year-Month-Day) and HH:MM (Hour:Minute) with the first number of the year selected as the active digit, indicated by the double-arrow cursor. 2. Press the UP or DOWN ARROW to change the active digit. Press the RIGHT ARROW to move the cursor to the next digit. Set all digits until the current Year-Month-Date and Hour:Minute display. 3. Press ENTER to save the setting and display the Home Screen. Step 6. Program the Controller via USB Flash Drive The easiest way to program the controller is to load previously created set-up files from a USB flash drive onto the controller. Settings that are not transferred via a USB drive are: Passwords (Installer & Manager); Machine Name; Company Name; Calibration. 1. Connect the USB flash drive containing set up files that were created in either the Formula Editor or on another controller. 2. From the Home Screen, press ENTER to launch the MAIN MENU. 3. Move the selection box to INSTALLER MENU by pressing and holding the DOWN ARROW. 4. Press ENTER and input the default Installer Password of 01234, using the UP ARROW to increment the number and the RIGHT ARROW to move the cursor. 5. Press ENTER to accept the password input. Select DATA TRANSFER from the Installer Menu and follow the sequence below:
Default Home Screen 1. Select Installer Menu 2. Input Password 3. Select Data Transfer
NOVA CONTROLS F01
MAIN MENU
EMERGENCY PUMP STOP LOAD SIZE: 200 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENU
INSTL PASSWORD
INSTALLER MENU
INSTALLER SERVICE INITIAL SYSTEM SETUP PROGRAM FORMULAS DATA TRANSFER SET UNITS OF MEASURE
4. Display Files on USB DATA TRANSFER
WRITE REPORTS READ SETUP WRITE SETUP UPDATE FIRMWARE OK EXIT
5. Send File to Controller SETUP FILE
POG Restaurants BLS Services Eclipse Hotel Hospital Settings International Hotel AA School District
6. Remove USB flash drive. Press EXIT
to return to the Installer Menu, in order to calibrate (required) and prime pumps.
Step 7. Calibrate Pumps You must calibrate all pumps to be used; programmed formulas will not run if pumps are not calibrated. Use CALIBRATE (VOLUME) only for medium (12 or 18 oz. / 355 or 532 ml. per minute) pumps.
1. Select Installer Service 2. Select Service Pumps
INSTALLER SERVICE
SERVICE PUMPS VIEW LOAD COUNT VIEW LOAD WEIGHT VIEW AMOUNT PUMPED CLEAR DATA LOG
3. Select Pump Calibration SERVICE PUMPS
PRIME PUMP PUMP CALIBRATION NAME PUMPS ENTER PRODUCT COSTS DATE TUBE CHANGED
4. Select Calibration Method PUMP CALIBRATION
VIEW CALIBRATION CALIBRATE (TIME) CALIBRATE (VOLUME)
5. Select Pump to Calibrate CALIBRATE (VOL.)
P1 P2 P3 P4 P5 P6
6. Collect 8 oz [250 ml] CALIBRATE
P2 STOP PUMP AT 8 OZ WARNING! PLACE CONTAINER AT OUTPUT! START/STOP EXIT
Use CALIBRATE (TIME) for large displacement pumps or for a flush installation. Press START and the timer counts down 20 seconds. DO NOT stop the pump; run it for a full 20 seconds, then enter the amount pumped.
5. Select Pump to Calibrate CALIBRATE (TIME)
6. Run Pump Full 20 Seconds
CALIBRATE
6.1 Input Amount Collected DISPENSED VOLUME
ENTER AMOUNT PUMPED 00.0 OZ
WARNING! PLACE CONTAINER AT OUTPUT! START/STOP EXIT
Step 8. Prime Pumps to start and stop prime. After priming is complete, press the EXIT Press Enter
1. Select Installer Service 2. Select Service Pumps 3. Select Prime Pump
KEY until
you reach the Home Screen.
6. Start/Stop Prime PRIME
5. Select Pump to Prime
SERVICE PUMPS
SET PRIME PUMP
START/STOP
P/N 20-09130-00A
Description of Controls and Operator Menu
Home Screen
The Home Screen appears after the controller language has been selected or whenever the controller is active. If no key is pressed for 15 minutes, Power Save turns off the displays backlight. Press any key to turn the backlight on and resume normal operation. If the controller is powered off, the last formula selected is the active formula on the Home Screen when power is turned back on. See the following graphic for an explanation of the information and symbols that may appear on the Home Screen.
Company Name (can be changed during System Setup)
NOVA CONTROLS F03 TOWELS
Pumps Trigger Signals
Current Formula (or Next Formula to Run) (Formula number appears if no name is input during System Setup) NON-ACTIVE Pump Not programmed or calibrated; not in formula
ACTIVE Pump Currently running READY Pump Calibrated and has amount(s) programmed ERROR in Pump Amount(s) programmed; not calibrated
_ 2 _ 4 _ _
Qualified Signal Receiving Signal (unqualified)
Non-Active Signal
Hot Keys: Formula Quick-Select
Main Menu
Formula Quick-Select
To prevent errors in data logging or chemical dispensing: Select the correct formula before washer operation starts and be sure that all programmed pumps are triggered during the cycle. From the Home Screen, press the EXIT key (also called FORMULA SELECT). 1. 2. Press the UP or DOWN ARROW to move the selection box to the correct formula. All formulas appear, but only formulas with programmed pumps are selectable. 3. Press ENTER to start the formula and return to the Home Screen. 4. (Optional) Press ENTER to reach the load size or bleach defeat settings.
Operator Main Menu
Formula Quick-Select NOVA CONTROLS F03 TOWELS _ _ 4 _ 5 _ 6 _
To reach the Main Menu from the Home Screen, press any key (except the EXIT key).
FO1 PADS F02 CURTAINS FO3 TOWELS F04 BED LINEN F05 BLANKETS F06 TABLE LINEN
SELECT FORMULA
EMERGENCY PUMP STOP LOAD SIZE 075 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENU
Emergency Pump Stop (stops all pumps and formulas) Load Size Menu (displays default load weight for formula. Input actual weight at start of each load). Selection Box Move box to select menu item. Press ENTER to launch selected menu Print Manager Reports Input Manager password, then FROM and TO date range. Installer Programs and Settings Input Installer password.
Press to Move Selection Box
Press to Select Formula
To Return to the Home Screen: Press EXIT
or wait 15 seconds without pressing a key.
Limited Warranty SELLER warrants solely to BUYER the Products will be free from defects in material and workmanship under normal use and service for a period of one year from the date of completion of manufacture. This limited warranty does not apply to (a) hoses; (b) and products that have a normal life shorter than one year; or (c) failure in performance or damage caused by chemicals, abrasive materials, corrosion, lightning, improper voltage supply, physical abuse, mishandling or misapplication. In the event the Products are altered or repaired by BUYER without SELLERS prior written approval, all warranties will be void. NO OTHER WARRANTY, ORAL, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, IS MADE FOR THESE PRODUCTS, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY EXCLUDED. SELLERS sole obligation under this warranty will be, at SELLERS option, to repair or replace F.O.B. SELLERS facility in Watsonville, California any Products found to be other than as warranted. Limitation of Liability SELLERS WARRANTY OBLIGATIONS AND BUYERS REMEDIES ARE SOLELY AND EXCLUSIVELY AS STATED HEREIN. SELLER SHALL HAVE NO OTHER LIABILITY, DIRECT OR INDIRECT, OF ANY KIND, INCLUDING LIABILITY FOR SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR FOR ANY OTHER CLAIMS FOR DAMAGE OR LOSS RESULTING FROM ANY CAUSE WHATSOEVER, WHETHER BASED ON NEGLIGENCE, STRICT LIABILITY, BREACH OF CONTRACT OR BREACH OF WARRANTY.
4 P/N 20-09130-00A
TOTAL ECLIPSE PRO Operator Menus
Formula Select
NOVA CONTROLS F02 CURTAINS 123X56788 _ 2 _ _ _ _
F01 PADS F02 CURTAINS F03 TOWELS F04 BED LINEN F05 BLANKETS F06 TABLE LINEN
Select & Return to Home Screen
Guide to Keypad & Menus
= SELECTION BOX
Emergency Pump Stop
UP/DOWN ENTER Key Arrows Move Launches Selection Box Menu Item
ENTER also Starts/Stops Action
EMERGENCY PUMP STOP LOAD SIZE 275 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENUS
EMERGENCY STOP
STOP ALL PUMPS AND FORMULAS
350 LBS =
EDIT VALUE LEFT/RIGHT UP/DOWN Arrows Input Arrows Move Cursor Value (0-9, A-Z)
F02 FO3 FO4
or ENTER Saves & Exits EXIT Only
Input Actual Load Weight
LOAD WEIGHT
220 LB (SINGLE LOAD) OK EXIT
MENU SYMBOLS
Steady On
More Items
Pumping (Flush Off)
Flushing
Pumping & Flushing
HOME SCREEN
Pump Icon
Trigger Signal Icon
Main Menu (User Prime Pump)
Select Pump to Prime (if enabled)
Start / Stop Prime Pump
Installer Menu Access
EMERGENCY PUMP STOP LOAD SIZE 180 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENUS
EMERGENCY PUMP STOP LOAD SIZE 220 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENUS
P1 PRE-WASH P2 DETERGENT P3 LIQUID BLEACH P4 BLEACH ALTERNATIVE P5 SOUR/CONDITI P6 ENZYME LIFT
P3 LIQUID BLEACH
Main Menu (User Manual Flush)
Start/Stop Flush (if flush enabled)
MANUAL FLUSH
Main Menu (Manager Reports)
Input Manager Password
MGR PASSWORD
Report Data Range FROM (Start Date)
REPORT DATE
FROM: 2009-06-01
Report Data Range TO (End Date)
TO: 2009-07-31
Set SAVE AS File Name*
REPORT NAME
WASH23 INSERT USB DRIVE OK EXIT
* Display returns to Main Menu after data transfer is complete.
TOTAL ECLIPSE PRO Top Level Installer Menus
(factory default settings shown in selection boxes)
Up / Down Arrow - Moves Selection Box - Changes digit value
Home Screen Main Menu Input Installer Password Installer Top Level Menu
01234 INSTALLER SERVICE INITIAL SYSTEM SETUP PROGRAM FORMULAS DATA TRANSFER SET UNITS OF MEASURE EXIT
MAIN MENU INSTL PASSWORD INSTALLER MENU
EMERGENCY PUMP STOP LOAD SIZE: 175 LB USER PRIME PUMPS USER MANUAL FLUSH MANAGER REPORTS INSTALLER MENUS
Right / Left Arrow During input, moves the cursor ( ) to the next digit
L E A D I N G
1.1 Pump Maintenance /Service 1.2 View Load Count 1.3 View Load Weight 1.4 View Amount Pumped 1.5 Clear Data Log
1. Service / Routine Maintenance
INSTALLER SERVICE SERVICE PUMPS
PRIME PUMP PUMP CALIBRATION NAME PUMPS ENTER PRODUCT COSTS DATE TUBE CHANGED OK F01 PADS F02 CURTAINS F03 TOWELS F04 BED LINEN F05 BLANKETS F06 TABLE LINEN F01 PADS F02 CURTAINS F03 TOWELS F04 BED LINEN F05 BLANKETS F06 TABLE LINEN P1 PRE-WASH P2 DETERGENT P3 LIQUID BLEAC P4 BLEACH ALT P5 SOUR/CONDITI P6 ENZYME LIFT 0.0 0.0 0.0 0.0 0.0 0.0
TOTAL LOAD COUNT
TOTAL WEIGHT
PUMPED (GAL)
ZERO DATA LOG
WARNING! ALL LOGS (LOADS & VOLUMES) WILL BE CLEARED! EXIT
Systems Company
2.1 Edit Installer Password INST PASSWORD
HOTEL ECLIPSE - 67
Enter / Save Key - Launches selected menu - Saves new input & exits
2. Initial System Setup
2.2 Edit Manager Password MGR PASSWORD 2.3 Set-up Operating Mode OPERATION MODE 2.4 Edit Account Name ACCOUNT NAME 2.5 Edit Machine Name MACHINE NAME
HOUSEKEEPING 01
SYSTEM SETUP
2.6 Edit Company Name COMPANY NAME
NOVA CONTROLS
2.7 Set Pump Interface (and Flush Time, if needed) PUMP INTERFACE
01234 OK EXIT OK OK EXIT EXIT
STANDARD RELAY EVENT GROUP OCCURRENCE
NON-FLUSH ECLIPSE FLUSH P. I. ORION I I FLUSH P. I. 8-PUMP FLUSH P. I. OK EXIT OK EXIT
EDIT INST PASSWORD EDIT MGR PASSWORD OPERATION MODE EDIT ACCOUNT NAME EDIT MACHINE NAME EDIT COMPANY NAME
2.8 Set Cycle Time Limit CYCLE TIME LIMIT
MINUTES 0 (0 = OFF) OK EXIT (0 = OFF) OK EXIT OK DISABLE ENABLE LIMITED 30 SEC
2.9 Set Trigger Signal Filter TRIGGER FILTER
2.10 Auto-Formula Select AFS TRIGGER
2.11 User Prime Enable SET USER PRIME
2.12 Adjust Screen Contrast LCD CONTRAST
2.13 Set Date & Time DATE & TIME
- - 28 YYYY-MM-DD EXIT OK EXIT OK 17:06 HH:MM EXIT
2.14 Clear Controller Settings CLEAR SETTINGS
WARNING! ALL SETUPS WILL BE CLEARED TO FACTORY DEFAULTS! OK EXIT
SET PUMP INTERFACE SET CYCLE TIME SIGNAL FILTER TIME SET AFS TRIGGER SET USER PRIME SET LCD CONTRAST SET DATE AND TIME CLEAR SETTINGS VIEW SOFTWARE ID
2 SECONDS 10 SECONDS 20 SECONDS 30 SECONDS 60 SECONDS 90 SECONDS
3. Formula Programming 3.1 Set Formula F01
F01 P1
P1 P1A P1B P1C DELAY AMOUNT AMOUNT AMOUNT 0 SEC 00.00 OZ 00.00 OZ 00.00 OZ
PUMP SETTINGS SET DEFAULT WEIGHT SET COUNT PUMP EDIT NAME CLEAR FORMULA
PROGRAM FORMULAS
3.1.2 Add Pumps to Formula F01 PUMPS 3.1.3 Pump Settings
3.2 Default Load Weight F01 LOAD SIZE
3.3 Set Count Pump F01 COUNT PUMP
3.4 Edit Formula Name NAME F01
NEW NAME
3.5 Clear Formula CLEAR F01
WARNING! FORMULA WILL BE CLEARED TO FACTORY DEFAULT!
F01 F02 CURTAINS F03 TOWELS F04 BED LINEN F05 BLANKETS F06 TABLE LINEN
P1 PRE-WASH P2 DETERGENT P3 LIQUID BLEACH P4 BLEACH ALT P5 SOUR/CONDITI P6 ENZYME LIFT
P2 DETERGENT P3 LIQUID BLEACH P4 BLEACH ALT P5 SOUR/CONDITI P6 ENZYME LIFT P7
4. Upload / Download Data
4.1 Set Report FROM / TO Date
4.1.2 Set SAVE AS File Name
4.2 Read Setup - Select File to load from USB to Controller
4.3 Write Setup - Name File being sent (from Controller to USB flash drive) 4.4 Update Firmware
4.5 Diagnostic Activity Log
225 Westridge Drive, Watsonville, California, USA 95076-3 1. 6. 0. 2. N OVA ( ) FA X : 1. 6. www.novac ont rols.c om
DATA TRANSFER
FROM: 2009-01-08 HI CAP WASH
SETUP FILE
SETUP NAME
HOTEL 17
UPDATE FIRMWARE
STOP!!! DO NOT PROCEED WITHOUT PC UPDATE PROGRAM! INSERT USB DRIVE OK EXIT
OK EXIT
POG Restaurants BLS Services Eclipse Hotel Hospital Settings International Hotel AA School District ABBA INSERT USB DRIVE OK EXIT
WRITE REPORTS READ SETUP WRITE SETUP UPDATE FIRMWARE WRITE ACTIVITY LOG TO: OK 2009-02-08
REPORTEXIT DATE
INSERT USB DRIVE OK EXIT
WARNING!
5. Set Units of Measure
UNITS-MEASURE
SAE / IMPERIAL (LB/OZ) METRIC (KG/ML)
Overwrites ALL settings & formulas, except passwords, machine name, company name & calibrations.
Overwrites le of same name on USB ash drive. Does not transfer passwords, machine name, company name or calibrations.
DO NOT attempt firmware update unless you have your PC Update Program and proper computer cable.
Tags
FK-103 Cileo Graph25 Valve Tomtom GO Electroplankton Stone Suite Sbcru252-00H MK77MV FX-82MS MC235B Litepro 730 WV-CU161 2150 CMD Urc-7541 CLX-3175N SEE SGH-F400 Futura 1000 AVD-S10 If-ED Sennheiser K6 MMS321 1000 VA RS2625 E1920NX K630I MVW680 Series Aspire 3050 MRO-DV100 VLF510 32LB9R1 Faxphone B160 Reference D4160 CDR-M30 1820M NW-E507 CLC4040-H1 SYS II 715 ES VGN-AR71M Infiniti G20 580 SC Jetflash PRO Z302 AJ3122 ZWS185W VGN-B1VP Dg130HA VGN-NR11m-S MX-S6MD CC470TW S C Primopdf HD9020 Canon I250 100 WD 19LG3100 AV 40 HT-TZ315T Purple DC-T850 Penta AD41 WA90V3 PEG-TJ27 E1 CFD-RG880CP SLD-200 TLP 450 Graphite 1500 PSC 2175 HR-S7600 730MP 10000 VA KDC-W657 Mouse HR-V505 Amplifier RX-450 WD-85260NP Hbmc-15 Calculator LE46B750 MT 600 Creator Yamaha P140 MHC-RG495 U-smart M228WDP-BZJ MCT 320 TX-32LXD700 WF8620NHW Micro Star Nokia 2650 LP210 KDE-50XS955 LC-52E77U ZTE130 RE-SX10 Review
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding