Omron H3CR-F
|
|
Bookmark Omron H3CR-F |
OMRON Electronics Electromechanical Multifunction H3CR-F AC100-240Electromechanical Multifunction Timer; Time Range:0.05 sec. to 30 hr. Supply Voltage AC, Min:100VAC; No. of Timing Functions:2; Body Material:38B610; No. of Pins:11; Supply Voltage AC, Max:240VAC; Mounting Type:Panel Mount ; RoHS Compliant: Yes
Details
Brand: OMRON
Part Numbers: H3CR-F AC100-240, H3CRFAC100240
[ Report abuse or wrong photo | Share your Omron H3CR-F photo ]
Manual
Download
(English)
|
Omron H3CR-F
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
Solid-state Twin Timers
H3CR-F
DIN 48 48-mm Twin Timers
Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of long ON- or OFF-time and short OFF- or ONtime settings are possible. Fourteen time ranges from 0.05 s to 30 h or from 1.2 s to 300 h depending on the model to be used. Models with a flicker ON start or flicker OFF start are available. Easy sequence checks through instantaneous outputs for a zero set value at any time range. Length, when panel-mounted with a Socket, of 80 mm or less. 11-pin and 8-pin models are available.
Model Number Structure
Model Number Legend
H3CR - F @ @ - @ @
1. Classification F: Twin timers 2. Configuration None: 11-pin socket 8: 8-pin socket
3. Twin Timer Mode None: Flicker OFF start N: Flicker ON start 4. Time Range None: 0.05 s to 30 h models 300: 1.2 s to 300 h models
5. Supply Voltage 100-240AC: 100 to 240 VAC 24AC/DC: 24 VAC/VDC 12DC: 12 VDC 48-125DC: 48 to 125 VDC
Ordering Information
List of Models
Operating modes Flicker OFF start Supply voltage 100 to 240 VAC 24 VAC/DC 12 VDC 48 to 125 VDC Flicker ON start 100 to 240 VAC 24 VAC/DC 12 VDC 48 to 125 VDC 0.05 s to 30 h models 11-pin models H3CR-F 100-240AC H3CR-F 24AC/DC H3CR-F 12DC H3CR-F 48-125DC H3CR-FN 100-240AC H3CR-FN 24AC/DC H3CR-FN 12DC H3CR-FN 48-125DC 8-pin models H3CR-F8 100-240AC H3CR-F8 24AC/DC H3CR-F8 12DC H3CR-F8 48-125DC H3CR-F8N 100-240AC H3CR-F8N 24AC/DC H3CR-F8N 12DC H3CR-F8N 48-125DC 1.2 s to 300 h models 11-pin models H3CR-F-300 100-240AC H3CR-F-300 24AC/DC H3CR-F-300 12DC H3CR-F-300 48-125DC H3CR-FN-300 100-240AC H3CR-FN-300 24AC/DC H3CR-FN-300 12DC H3CR-FN-300 48-125DC 8-pin models H3CR-F8-300 100-240AC H3CR-F8-300 24AC/DC H3CR-F8-300 12DC H3CR-F8-300 48-125DC H3CR-F8N-300 100-240AC H3CR-F8N-300 24AC/DC H3CR-F8N-300 12DC H3CR-F8N-300 48-125DC
Note: Specify both the model number and supply voltage when ordering. Example: H3CR-F 100-240AC Supply voltage
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Accessories (Order Separately)
Name/specifications Flush Mounting Adapter Y92F-30 Y92F-73 Y92F-74 Mounting Track 50 cm (l) 7.3 mm (t) 1 m (l) 7.3 mm (t) 1 m (l) 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket 8-pin 8-pin, finger safe type 11-pin 11-pin, finger safe type Back Connecting Socket 8-pin 8-pin, finger safe type 11-pin 11-pin, finger safe type Hold-down Clip (See note 2) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-7 Y92H-8 Models
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket. 2. Hold-down Clips are sold in sets of two.
Specifications
General
Item Operating mode Pin type Operating/Reset method Output type Mounting method Approved standards 11-pin Relay output (DPDT) DIN track mounting, surface mounting, and flush mounting UL508, CSA C22.2 No.14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. H3CR-F Flicker OFF start 8-pin Time-limit operation/Time-limit reset or self-reset H3CR-F8 11-pin H3CR-FN Flicker ON start 8-pin H3CR-F8N
Time Ranges
0.05 s to 30 h Models
Time unit Setting 1.0.05 to 1.2 0.3 to 3 1.2 to to 30 s (sec) 10 s (10 sec) 1.2 to to to to 300 0.3 to 3 1.2 to to 30 min (min) 0.12 to 1.2 h (hrs)
Note: Instantaneous output is available at any time range. To obtain instantaneous output, set to below 0.
1.2 s to 300 h Models
Time unit Setting 1.10 s (10 sec) 1.2 to to to to min (10 min) 1.2 to to to to 300 0.3 to 3 1.2 to to 30 h (hrs) 0.12 to 1.h (10 hrs) 1.2 to to to to 300
Ratings
Rated supply voltage (See notes 1, 2, and 3.) 100 to 240 VAC (50/60 Hz),12 VDC, 24 VAC/DC (50/60 Hz), 48 to 125 VDC Operating voltage range Power reset Power consumption 85% to 110% of rated supply voltage; 90% to 110% with 12-VDC models Minimum power-opening time: 0.1 s 100 to 240 VAC: approx. 10 VA (2.1 W) at 240 VAC 24 VAC/VDC: approx. 2 VA (1.7 W) at 24 VAC approx. 1 W at 24 VDC 48 to 125 VDC: approx. 1.5 W at 125 VDC 12 VDC: approx. 1 W at 12 VDC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1)
Control outputs
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model. 2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 3. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
Characteristics
Accuracy of operating time Setting error Reset time Reset voltage Influence of voltage Insulation resistance Dielectric strength 0.2% FS max. (0.2% FS 10 ms max. in ranges of 1.2 and 3 s) 5% FS 50 ms max. 0.1 s max. 10% max. of rated voltage 0.2% FS max. (0.2% FS 10 ms max. in ranges of 1.2 and 3 s) 100 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) 3 kV (between power terminals) for 100 to 240 VAC, 48 to 125 VDC 1 kV for 12 VDC, 24 VAC/DC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC, 48 to 125 VDC 1.5 kV for 12 VDC, 24 VAC/DC 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) 400 V for 12 VDC Malfunction: 8 kV Destruction: 15 kV Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions Destruction: 980 m/s2 three times each in six directions Malfunction: 98 m/s2 three times each in six directions Operating: Storage: Operating: 10C to 55C (with no icing) 25C to 65C (with no icing) 35% to 85%
ON OFF ON OFF 0.1 s min.
Output NC
Flicker ON start
Power ON OFF tON tOFF tON tOFF
Lit ON indicator Not lit Lit OFF indicator Not lit Output NO ON OFF ON OFF
Note: 1. The reset time requires a minimum of 0.1 s. 2. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer.
Nomenclature
OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min., and hrs, or from 10 s, 10 min, hrs, and 10 h)
Scale range display windows
ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting
Time range selector (select one from 1.2, 3, 12, and 30 at full scale) For both ON-time and OFF-time.
ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300
17.4 5.7 6
66.6 52.3
37 dia. 14 dia.
44.8 44.8
R1.pins
H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300
Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@
Dimensions with Back Connecting Socket P3G-08/P3GA-11
17.4 81.17.4 81.5 75
H3CR-F H3CR-FN 103.2* 100.9 92.3*
H3CR-F8 H3CR-F8N 90.0 H3CR-F H3CR-FN
H3CR-F8 H3CR-F8N
Y92F-30 P2CF-11 P2CF-11-E
P2CF-08 P2CF-08-E
P3GA-11 (When Y92A-48G mounted)
Y92F-30
P3G-08 (When Y92A-48G mounted)
*These dimensions vary with the kind of DIN track (reference value).
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.
Solid-state Star-delta Timers
H3CR-G
DIN 48 48-mm Star-delta Timer
A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 0.5 seconds).
H3CR - G 8 @ L @
1. Classification G: Star-delta timer 2. Configuration 8: 8-pin socket
3. Outputs None: Star-delta operation contact E: Star-delta operation contact and instantaneous contact 4. Dimensions L: Long-body model
5. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC
Outputs Time-limit contact Time-limit contact and instantaneous contact Supply voltage 100 to 120 VAC 200 to 240 VAC 100 to 120 VAC 200 to 240 VAC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-G8L 100-120AC Supply voltage H3CR-G8L 100-120AC H3CR-G8L 200-240AC H3CR-G8EL 100-120AC H3CR-G8EL 200-240AC 8-pin models
Accessories (Order Separately)
Name/specifications Flush Mounting Adapter Y92F-30 Y92F-70 Y92F-71 Mounting Track 50 cm (l) 7.3 mm (t) 1 m (l) 7.3 mm (t) 1 m (l) 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket Back Connecting Socket Time Setting Ring Panel Cover (See note 2) 8-pin 8-pin, finger safe type 8-pin 8-pin, finger safe type Setting a specific time Limiting the setting range Light gray (5Y7/1) Black (N1.5) Medium gray (5Y5/1) Hold-down Clip (See note 3) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 Models
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. 2. The Time Setting Ring and Panel Cover are sold together. 3. Hold-down Clips are sold in sets of two.
Item Functions Pin type Operating/Reset method Output type Star-delta timer 8-pin Time-limit operation/Self-reset Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Instantaneous: SPST-NO H3CR-G8L H3CR-G8EL Star-delta timer with instantaneous output
Mounting method Approved standards
DIN track mounting, surface mounting, and flush mounting UL508, CSA C22.2 No.14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1.
Time unit Full scale setting Star-delta transfer time 0.5 to 6 s 1 to 12 s 5 to 60 s 10 to 120 s Programmable at 0.05 s, 0.1 s, 0.25 s or 0.5 s Star operation time ranges
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz) Operating voltage range Power reset Power consumption Control outputs 85% to 110% of rated supply voltage Minimum power-opening time: 0.5 s 100 to 120 VAC: approx. 6 VA (2.6 W) at 120 VAC 200 to 240 VAC: approx. 12 VA (3.0 W) at 240 VAC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1)
Note: 1. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 2. Refer to Safety Precautions for All Timers when using the Timer together with a 2-wire AC proximity sensor.
Accuracy of operating time Setting error Accuracy of Star-delta transfer time Reset voltage Influence of voltage Insulation resistance Dielectric strength 0.2% FS max. 5% FS 50 ms max. 25% FS + 5 ms max. 10% max. of rated voltage 0.2% FS max. 100 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) 3 kV (between power terminals) 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) 1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Malfunction: 8 kV Destruction: 15 kV Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions Destruction: 980 m/s2 three times each in six directions Malfunction: 294 m/s2 three times each in six directions Operating: Storage: Operating: 10C to 55C (with no icing) 25C to 65C (with no icing) 35% to 85%
6 (78.0) 63.7 0.7
39 dia.
44.8 44.pins
Dimensions with Set Ring
42 dia.
Time setting ring
Panel cover
Dimensions with Front Connecting Socket P2CF-08-@
Dimensions with Back Connecting Socket P3G-08
15 92.9 86.4
101.3*
H3CR-G8@L
99 H3CRG8@L
Y92F-30 P2CF-08 P2CF-08-E
Solid-state Power OFF-delay Timers
H3CR-H
DIN 48 48-mm Power OFF-delay Timer
Long power OFF-delay times; S-series: up to 12 seconds, M-series: up to 12 minutes. Models with forced-reset input are available. 11-pin and 8-pin models are available.
Note: This model number legend includes combinations that are not available. Before ordering, please check the List of Models on page 1 for availability.
H3CR - H @ @ L @ @
1. Classification H: Power OFF-delay timer 2. Configuration None: 11-pin socket 8: 8-pin socket
3. Input None: Without reset input R: With reset input 4. Dimensions L: Long-body model
5. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC 48DC: 48 VDC 100-125DC: 100 to 125 VDC
6. Time Range S: 0.05 to 12 s M: 0.05 to 12 min
Input Output Supply voltage 11-pin models Without DPDT reset input 100 to 120 VAC --200 to 240 VAC 24 VAC/DC 48 VDC 100 to 125 VDC With reset input 200 to 240 VAC H3CR-HRL 200-240AC S 24 VAC/DC 48 VDC SPDT H3CR-HRL 24AC/DC S H3CR-HRL 48DC S S-series 8-pin models H3CR-H8L 100-120AC S H3CR-H8L 200-240AC S H3CR-H8L 24AC/DC S H3CR-H8L 48DC S H3CR-H8L 100-125DC S H3CR-HRL 200-240AC M H3CR-HRL 24AC/DC M H3CR-HRL 48DC M H3CR-HRL 100-125DC M H3CR-H8RL 100-120AC S --H3CR-H8RL 200-240AC S H3CR-H8RL 24AC/DC S H3CR-H8RL 48DC S H3CR-H8RL 100-125DC S H3CR-H8RL 100-120AC M H3CR-H8RL 200-240AC M H3CR-H8RL 24AC/DC M H3CR-H8RL 48DC M H3CR-H8RL 100-125DC M --11-pin models M-series 8-pin models H3CR-H8L 100-120AC M H3CR-H8L 200-240AC M H3CR-H8L 24AC/DC M H3CR-H8L 48DC M H3CR-H8L 100-125DC M H3CR-HRL 100-120AC M ---
100 to 120 VAC H3CR-HRL 100-120AC S ---
100 to 125 VDC H3CR-HRL 100-125DC S 100 to 120 VAC --200 to 240 VAC 24 VAC/DC 48 VDC 100 to 125 VDC
Note: Specify the model number, supply voltage, and time range (S or M) when ordering. Example: H3CR-H8L 100-120AC S Time range Supply voltage
Name/specifications Flush Mounting Adapter Y92F-30 Y92F-70 Y92F-71 Mounting Track 50 cm (l) 7.3 mm (t) 1 m (l) 7.3 mm (t) 1 m (l) 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket 8-pin 8-pin, finger safe type 11-pin 11-pin, finger safe type Back Connecting Socket 8-pin 8-pin, finger safe type 11-pin 11-pin, finger safe type Hold-down Clip (See note 2) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P2CF-11 P2CF-11-E P3G-08 P3G-08 with Y92A-48G (See note 1) P3GA-11 P3GA-11 with Y92A-48G (See note 1) Y92H-1 Y92H-2 Models
Item Operating/Reset method Pin type Input type Output type Mounting method Approved standards H3CR-H8L H3CR-H8RL H3CR-HRL Instantaneous operation/Time-limit Instantaneous operation/Time-limit reset/Forced reset reset 8-pin --Relay output (DPDT) No-voltage Relay output (SPDT) Relay output (DPDT) 11-pin
Time unit Setting 0.6 1.12 Min. power ON time Time-up operation repeat period Forced-reset repeat period 0.05 to 0.6 0.12 to 1.2 0.6 to 6 1.2 to 12 0.1 s min. 3 s min. 3 s min. 2 s min. S-series s (sec) M-series min (min)
Note: 1. If the above minimum power ON time is not secured, the H3CR may not operate. Be sure to secure the above minimum power ON time. 2. Do not use the Timer with a repeat period of less than 3 s. Doing so may result in abnormal heating or burning. Refer to Safety Precautions (H3CR-H) on page 8 for details.
Rated supply voltage (See notes 1 and 2.) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz), 24 VAC/VDC (50/60 Hz), 48 VDC, 100 to 125 VDC Operating voltage range No-voltage input (See note 3.) 85% to 110% of rated supply voltage ON-impedance: 1 k max. ON residual voltage: 1 V max. OFF impedance: 500 k min. 100 to 120 VAC: approx. 0.23 VA (0.22 W) at 120 VAC 200 to 240 VAC: approx. 0.35 VA (0.3 W) at 240 VAC 24 VAC/DC: approx. 0.17 VA (0.15 W) at 24 VAC approx. 0.1 W at 24 VDC 48 VDC: approx. 0.18 W at 48 VDC 100 to 125 VDC: approx. 0.5 W at 125 VDC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1)
Power consumption
Note: 1. A power supply with a ripple of 20% max. (single-phase power supply with full-wave rectification) can be used with each DC Model. 2. Do not use an inverter output as the power supply. Refer to Safety Precautions for All Timers for details. 3. For contact input, use contacts which can adequately switch 1 mA at 5 V.
Accuracy of operating time Setting error Operation start voltage Influence of voltage Insulation resistance Dielectric strength 0.2% FS max. (0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s) 5% FS 50 ms max. 30% max. of rated voltage 0.2% FS max. (0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s) 100 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying metal parts) 2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit) 2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities) 1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other) 3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC; 1 kV for 24 VAC/DC, 48 VDC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC; 1.5 kV for 24 VAC/DC, 48 VDC 1.5 kV (between power terminals) and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise); 1 kV (between power terminals) for 48 VDC Malfunction: 8 kV, Destruction:15 kV Destruction: 10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions Malfunction: 10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions Destruction: 980 m/s2 three times each in six directions Malfunction: 98 m/s2 three times each in six directions Operating: Storage: Operating: 10C to 55C (with no icing), 25C to 65C (with no icing) 35% to 85%
Influence of temperature 1% FS max. (1% FS 10 ms max. in ranges of 0.6 and 1.2 s)
Mechanical: 10 million operations min. (under no load at 1,200 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h) (See note) EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (9005 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Light Gray (Munsell 5Y7/1) IP40 (panel surface) Approx. 120 g (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD:
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC for H3CR-H8L/-HRL and 100 mA at 5 VDC for H3CR-H8RL (failure level: P).
Without Reset Input (H3CR-H8L)
Time range/ unit selector
Oscillation circuit
Counting circuit
Power failure detection circuit
LCD LCD
Output indicator
With Reset Input (H3CR-H8RL/-HRL)
Reset input
Input circuit
Inputs Outputs Reset Control output Turns off the control output and resets the elapsed time. Operates instantaneously when the power is turned on and time-limit resets when the set time is up after the power is turned off.
Note: DC models, including 24 VAC/DC models, have polarity.
8-pin Models Without Reset Input (H3CR-H8L)
With Reset Input (H3CR-H8RL)
Power supply Note: Leave terminal 3 open. Do not use them as relay terminals.
11-pin Model With Reset Input (H3CR-HRL)
Power supply Note: Leave terminal 6 open. Do not use them as relay terminals.
t: Set time Rt: Minimum power ON time (S-series: 0.1 s min.; M-series: 2 s min.) If the power ON time is less than this value, the Timer may not operate (i.e., output may not turn ON). Model H3CR-H8L
Power (See note) ON OFF Rt
t Rt t
Output (1 3)
Output (1 4)
Output (8 6)
Output (8 5)
Lit Not lit Rt Rt t 0.05 s min. t 0.05 s min.
H3CR-H8RL
Power (See note) ON OFF
ON (Short-circuited) Reset input OFF (Open)
Lit Not lit
H3CR-HRL
Rt t 0.05 s min.
0.05 s min. Reset input
Output (11 9)
Output (11 8)
Note: If the power is turned ON until the set time is up, the timer will be retriggered.
Output indicator (red) Scale range display windows
Time setting knob (for setting power OFF-delay time)
Time range selector (select one from 0.6, 1.2, 6, and 12 at full scale)
Time unit display S-series: sec M-series: min
H3CR-H8L H3CR-H8RL
6 78.0 63.7 0.7
92.9 86.4 92.9 91.4
15 H3CR-H8@L 101.3* 99 112.2* H3CR-HRL 109.9
H3CRH8@L
P2CF-11 P2CF-11-E
Safety Precautions (H3CR-H)
Note: The undermentioned is common for all H3CR-H models.
Power Supplies
The H3CR-H has a large inrush current; provide sufficient power supply capacity. If the power supply capacity is too small, there may be delays in turning ON the output. With the H3CR-H@RL, for the power supply of an input device, use an isolating transformer, of which the primary and secondary windings are mutually isolated and the secondary winding is not grounded.
Wiring
The H3CR-H has a high impedance circuit. Therefore, the H3CR-H may not be reset if the H3CR-H is influenced by inductive voltage. In order to eliminate any influence of inductive voltage, the wires connected to the H3CR-H must be as short as possible and should not be installed alongside power lines. If the H3CR-H is influenced by inductive voltage that is 30% or more of the rated voltage, connect a CR filter with a capacitance of approximately 0.1 F and a resistance of approximately 120 or a bleeder resistor between the power supply terminals. If there is any residual voltage due to current leakage, connect a bleeder resistor between the power supply terminals.
Correct
H3CR-H@RL 4*, 7 1*, 5 Input terminal 10, 7* 2, 2* Power supply
Operation
An interval of 3 s minimum is required to turn on the H3CR-H after the H3CR-H is turned off. If the H3CR-H is turned on and off repeatedly with an interval of shorter than 3 s, abnormal heating or burning may occur in internal elements.
3 s min.
* :H3CR-H8RL
Input device Isolation transformer is required.
Incorrect
H3CR-H@RL 4*, 7 Input terminal 10, 7* Power supply
Output state 1 Output state 2
After the forced reset function of the H3CR-H is activated, an interval of 3 s minimum is required to activate the forced reset function again. If the forced reset function is activated repeatedly with an interval of shorter than 3 s, the internal parts of the H3CR-H may deteriorate and the H3CR-H may malfunction.
Input device
Isolation transformer
Power 3 s min. Reset input 3 s min.
Input/Output (H3CR-H@RL)
An appropriate input is applied to the input signal terminal of the Timer when the input terminal for the input signal is short-circuited. Do not attempt to connect any input terminal to any terminal other than the input terminal or to apply voltage across other than the specified input terminals or the internal circuits of the Timer may be damaged. The H3CR-H@RL uses transformerless power supply. When connecting a relay or transistor as an external signal input device, pay attention to the following points to prevent short-circuiting due to a sneak current to the transformerless power supply. If input is made simultaneously from one input contact or a transistor to the H3CR-H and a Timer whose common input terminals are used as power terminals, such as the H3CR-A, a short-circuit current will be generated. Either input through isolated contacts, or isolate the power supply for one of the Timers.
4*, 7 1*, 5 G. S. R. 7 H3CR-A H3CR-H@RL 10, 7* 2, 2* Short-circuit current 10 2
Output
If it is required that the output be turned on repeatedly with an interval of shorter than 3 s, consider use of the H3CR-A in mode D (signal OFF-delay).
Others
If the H3CR-H is dropped or experiences some other kind of shock, because a latching relay is used for output, contacts may be reversed or go into a neutral state. If the H3CR-H is dropped, reconfirm correct operation.
*: H3CR-H8RL
Safety Precautions for All Timers
Refer to the Safety Precautions for individual Timers for precautions specific to each Timer.
!WARNING
The following Timers contain lithium batteries that are not explosion proof. 1. Timers with Built-in Batteries: H5L The Timer contains a lithium battery, which may occasionally ignite or rupture. Do not disassemble, deform under pressure, heat to 100C or higher, or incinerate the Timer. 2. Timers with Replaceable Batteries: Y92S-20 (for H5CN-M) The battery may occasionally rupture, ignite, or leak fluid. Do not short the positive and negative terminals. Do not charge, disassemble, deform under pressure, or throw the battery into a fire. If a non-specified battery is used, the battery may leak fluid or rupture, occasionally resulting in equipment failure or minor injury. Use only the specified battery.
Normal operation may not be possible in locations subject to sulfidizing gas, such as in sewer systems or waste incinerators. OMRON does not market any Timers or other control devices for operation in atmospheres containing sulfidizing gas. Seal the Timer so that sulfidizing gas will not enter it. If sealing is not possible, OMRON does provide special Timers with improved resistance to sulfidizing gas. Ask your OMRON representative for details.
Power Supply
Be sure that the voltage applied is within the specified range, otherwise the internal elements of the Timer may be damaged. Install a switch or circuit breaker that allows the operator to immediately turn OFF the power, and label it to clearly indicate its function. Maintain voltage fluctuations in the power supply within Allowable Voltage Range the specified range.
!CAUTION
The following Timers contain lithium batteries that are explosion proof. Timers with Built-in Batteries: H5BR, H5AN-4DM, H5S, H5F, and H4KV The Timer contains a lithium battery, which may occasionally ignite or rupture. Do not disassemble, deform under pressure, heat to 100C or higher, or incinerate the Timer. Use a commercial power supply for the power supply voltage input to models with AC inputs. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Timer may result in ignition or burning. Do not use an inverter output for the power supply of the Timer. The Timers listed below cannot be directly turned ON and OFF by using an AC 2-wire proximity sensor to turn the Timer's power supply ON and OFF. Use the following countermeasure when using an AC 2-wire proximity sensor with the Timer. (The power supply circuit in the Timer uses half-wave rectification. Only a half AC wave is supplied to the proximity sensor, which may cause operation to be unstable.)
Precautions for Safe Use
Operating Environment
Use the Timer within the ratings specified for ambient operating temperature and ambient operating humidity for each model. Store the Timer with the specified temperature range for each model. If the Timer has been stored at a temperature of less than 10C, allow the Timer to stand at room temperature for at least 3 hours before using it. Use the Timer within the performance specified for water and oil exposure for each model. Do not use the Timer in locations subject to shock and vibration. Long-term usage in such locations may damage the Timer due to stress. Magnetic contactors generate a shock of 1,000 to 2,000 m/s2 when switching a load. When mounting to DIN Track, separate magnetic contactors from the Timer so that the Timer is not subjected to vibration and shock. Use anti-vibration rubber. Do not use the Timer in locations subject to excessive dust, corrosive gases, or direct sunlight. Do not use organic solvents (such as paint thinner or benzine), strong alkalis, or strong acids because they will damage the external finish of the Timer. Separate the input devices, input wiring, and Timer as far as possible from sources of noise and power lines carrying noise. When using the Timer in environments subject to large amounts of static electricity (e.g., pipes carrying molding materials, powders, or fluid materials), separate the Timer as far as possible from the sources of static electricity. Do not remove the external case from the Timer. Do not use the Timer in locations where condensation may occur due to high humidity or sudden temperature changes. Condensation inside the Timer may result in malfunction or damage to Timer elements. The life of internal parts may be reduced if Timers are mounted in close proximity to each other. Resin and rubber parts (e.g., rubber packing) may deteriorate, shrink, or harden depending on the operating environment (e.g., subjected to corrosive gases, ultraviolet light, or high temperatures). We recommend periodic inspection and replacement.
Applicable Models
H3Y, H3YN, H3RN, H3CA-8, RD2P, and H3CR(-A, -A8, -AP, -F, and -G)
Countermeasure
Wire through a relay and use the relay contacts to turn the power supply ON and OFF. Confirm the stability of operation after making the connections. Install protective measures (such as earth leakage breakers, wiring breakers, or fuses) on the power supply side according to any applicable laws or regulations.
Correctly Handling Input Signals
Malfunction due to noise may occur if input wiring is placed in the same duct or conduit as power lines or high-voltage lines. Separate input wiring from power lines and wire them in a separate system. Also, use shielded cables, use metal conduits, and keep wiring distances as short as possible.
Other Precautions
Confirm that you have the correct model before using it. Be sure that all terminals are wired correctly. Always test the output status with a tester before using a Timer with a built-in keep relay (e.g., the H3CR-H and H3DE-H). Shock resulting from dropping the Timer during transport or handling may cause the output contacts to reverse or to be in a neutral status. Leaving the Timer with outputs ON at a high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Use the Timer in combination with relays and avoid leaving the Timer with the output turned ON for an extended period of time (e.g., for more than a month). Reference Example (Use the Timer as shown below.)
Timers with Relays
Do not connect a load that exceeds contact ratings, such as the switching capacity (contact voltage or contact current). Insulation faults, contact welding, contact faults, and other failures to achieve specified performance may occur and the relay may be damaged or may burn. Continued use with deteriorated performance may ultimately result in insulation breakdown between circuits or relay burning. The life of the built-in relay is greatly affected by switching conditions. Before using the Timer, test operation under actual application conditions and confirm that the switching frequency presents no problems in performance. Electrical life depends on the type of load, switching frequency, and ambient environment. Observe the following precautions when using the Timer. When switching a DC load, contact transfer may cause the contacts to stick or may cause contact failure. Confirm applicability and consider using a surge absorbing element. When switching at high frequencies, heat generated by arcing may cause contacts to melt or may cause metal corrosion. Consider connecting an arc absorbing element, reducing the switching frequency, or lowering the humidity. The surge current depends on the type of load, which also affects contact switching frequency and the number of operations. Check the rated current and the surge current, and design the circuits with sufficient margin. Resistive load Solenoid load Rated current 10 to 20 times the rated current Capacitor loads Motor load 5 to 10 times the rated current Transformer loads 5 to 15 times the rated load Incandescent lamp load 10 to 20 times the rated current Mercury light loads 1 to 3 times the rated load
Auxiliary relay (e.g., MY Relays)
Be sure that only a qualified worker (e.g., an electrical engineer) performs electrical work for the Timer.
Sodium light loads
1 to 3 times the 20 to 40 times rated load the rated load
Arcing when switching and relay heating may result in ignition or explosion. Do not use the Timer in atmospheres subject to inflammable or explosive gases. Contact faults may occur. Do not use the Timer in atmospheres subject to sulfidizing gas, chloride gas, or silicon gas. The switching capacity for DC voltage loads is lower than that for AC voltage loads.
Timers with Non-contact Outputs
Short faults or open faults may occur due to destruction of the output element. Do not use the Timer for a load that exceeds the rated output current. Short faults or open faults may occur due to destruction of the output element from reverse electromotive force. When using the Timer for a DC inductive load, always connect a diode as a countermeasure against reverse electromotive force.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specied) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ERRORS AND OMISSIONS
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRONs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
COPYRIGHT AND COPY PERMISSION
This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.
2007. 3
OMRON Corporation
Industrial Automation Company
In the interest of product improvement, specifications are subject to change without notice.
Tags
KEH-M7400RDS Grandprix 2000 Pocket DJ PV-DV102D 3232C CF-430H DV7832NXC NVD-Z001 - 2001 TNS410 Primavera 32LG50D RC-850 RN-502 SGH-F700 Extensa 390 SL-P999 RA 680 Mark II KD-G161 PRO900 701 TC Powermax 230 DA6502 PC-104-PS 29PT552A-78R KV-32LS35B AES-FG CFD-E95L Travelmate 2440 VGN-UX380N Benq T705 AW0891L Review Panasonic S50 VGN-TZ31wn B IP2500 BSS610RFE AN-12 YST-MS55D DDX8027 3507722 Inspiron 8000 760-779 KDC-334SA RQ-SX65F 84250B-t HD WD900DSP23S Speaky Hdmi Reference TH-37PA20 LE32A430 P1453S AVR-681 RDR-GX3 Grill 2000LE Supplement DR7621W Airoma IPE Travelmate 4230 6 JM4 VGN-UX180P DS125-JD MC235B M1910A-BZ Contax NX DT 290 VGN-NR31e S Manuel Isis 5 0 Mcbr170W 300 Trio Triumph 5000 KX-TCD420RU H2WR54G AVR-1905 21PV340 817-1 ETS-2104 I FAX-L100 XU 04XX Gateway DPF-D70 B3900 CW-75 NW-S703F Server Mity 2 KHX1600C9d3b1k2-4G CDR775-00 15HP-1998 PCG-TR1MP SV-AS10 YO-YO 4110XM CE1031 Yamaha R-3 RHC-10 LN32C530f1F MZ-N10
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101