Oregon Scientific RGR122
Oregon Scientific RGR122 Long Range Rain Gauge & Self-Emptying CupRemote control self dumping rain gauge. Check daily or total rainfall, or recall daily data from previous nine days. Electronically measure rainfall within 1/10th of an inch. Empty the container via remote. LCD includes indoor temperature.
Details
Brand: Oregon Scientific
Part Number: RGR122
UPC: 734811165367
[ Report abuse or wrong photo | Share your Oregon Scientific RGR122 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Oregon Scientific RGR122, size: 109 KB |
Oregon Scientific RGR122
User reviews and opinions
| Enviromon |
10:00am on Sunday, July 18th, 2010 ![]() |
| Performs as expected Works great. I assume the temperature is accurate, although I have never verified it. Out of the box, did not work I spent half hour (not counting opening the package it was packed it) trying to get the time set. No luck. | |
| zerbo |
1:09pm on Saturday, June 19th, 2010 ![]() |
| GREAT BUY I just love this indoor/outdoor thermometer. I live along the Adirondack Parkway in NY and temperature change daily. GREAT PRODUCT!! I LOVE THE FACT THAT THEY HAVE A SCREW WITH A KIND OF A HANDLE WIRE THING THAT HOLDS THE THING THAT TELLS YOU THE TEMP OUTSIDE.... | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

REMOTE RAIN GAUGE MODEL: RGR122 USERS MANUAL
INTRODUCTION
Congratulations on your purchasing the RGR122 Remote Rain Guage. The rain guage is equipped with the following functions: - Daily and total rainfall display - Nine-day rainfall history - Rainfall alarm - Indoor temperature display - Maximum and minimum temperatures - Real-time calendar clock - Daily alarm - 300-feet transmission range The RGR122 operates at 433MHz. No wire installation is required.
MAIN FEATURES: MAIN UNIT
A. FOUR-LINE DISPLAY - For displaying the total rainfall, current rainfall or rainfall history, indoor temperature and calendar clock B. RAIN RESET / SINCE BUTTON Displays the start day for total rainfall Presses and hold to clear the total and current rainfall Press and hold to reset the date stamp
I. [C/F] SWITCH - Selects between degree Centigrade (C) and Fahrenheit (F) J. [in/mm] SWITCH - Selects between inch and millimeter K. RAIN AL ON / OFF SWITCH - Turns on or off the rainfall alarm L. RESET BUTTON - Returns all settings to their default values M. CLOCK AL ON / OFF SWITCH - Turns on or off the daily alarm N. BATTERY COMPARTMENT - Accommodates two UM-3 or AA-sized batteries O. REMOVABLE TABLE STAND - For securing the main unit on a flat surface
C. RAIN SEARCH BUTTON - Enforces a search for the rain guage sensor D. MODE BUTTON - Changes among the clock, calendar and daily alarm in normal mode - Presses and hold to enter the setting mode E. TEMP MEM BUTTON [ ] - Changes among the maximum, minimum and current indoor temperatures in normal mode - Presses and hold to clear the temperature memory in normal mode - Decreases a value in setting mode F. RAIN HIST BUTTON [ ] - Displays the rainfall history in normal mode - Increases a value in setting mode G. RAIN ALARM [ ] BUTTON - Displays the rain alarm setting - Presses and hold to enter the rain alarm setting mode H. ANTENNA - Receives radio signal from rain collector 2
MAIN FEATURE: RAIN COLLECTOR
INSTALLATION
1. Position the main unit and rain collector within effective range (300 feet). 2. a) Insert batteries into the rain collector.
TOP VIEW
b) Mount the rain collector on a level surface c) Put drops of water on the cross at the base to check the leveling
Water stay at position 1 - 4 means the gauge is not leveled
! "
d) Use the metal ring to adjust the leveling of the rain collector P. Q. R. ANTENNA Transmits radio signal to main unit CROSS Checks the leveling of the rain collector BATTERYCOMPARTMENT Accommodates two UM-3 or AA-sized batteries 3
"AA" UM3 1.5 V
"AA" UM3 1.5V
METAL RING
3. Remove the fiber tape from around the bucket assemblies.
Note : Every time the battery in the main unit is changed, repeat installation step 4 to 7 before use.
TOTAL RAINFALL
The total rainfall is displayed on the top line of the LCD display. Use the [IN/MM] switch to select between inch and millimeter. To display the commencing date of the record, press [RAIN RESET/ SINCE] once. The date will appear on the bottom line of the display. To clear the record, hold [RAIN RESET/SINCE] for two seconds. Note that this will also clear the current (Day 0) rainfall.
4. Insert batteries into the main unit.
MODE L NO. RG R12 2
C in RAIN C LOC K RESE T F mm
RAINFALL HISTORY
The rainfall history is displayed on the second line of the LCD display. The main unit can record up to nine days of rainfall. Use [RAIN HIST / ] to display the record for a particular day. The day of the record will be displayed with a minus (-) sign. Zero (0) means the record is for the current day. To clear the current day rainfall, hold [RAIN RESET/SINCE] for two seconds. Note that this will also clear the total rainfall record.
"AA" U M3 1.5V
5. Press the [RESET] button on the main unit to initiate operation. 6. Set the calendar and clock. 7. Press [RAIN RESET / SINCE] to display the date stamp. Press and hold to reset the date stamp to current date.
RAINFALL ALARM
To set the rainfall alarm, 1. Press and hold [RAIN ALARM]. The alarm will be activated automatically. The rain alarm indicator will light up. 2. Use [RAIN HIST / ] to increase the setting or [TEMP MEM / ] to decrease the setting. 4
LOW BATTERY WARNING
There are two low-battery indicators, one appears on the total rainfall display section and one on the indoor temperature display section. The former represents the batteries of the remote rain collector, the latter those of the main unit. Replace the batteries immediately when the respective indicator lights up.
The alarm will go off for one minute when the rainfall reaches the preset value and the rain alarm indicator will flash. A reminder beep will be emitted every minute. Once the rain alarm is on the indicator will not stop flashing unless [RAIN AL] switch is turned off or the rain alarm value is reset or normally pass to next day. To stop the alarm and reminder beep, press any button or reset the rainfall alarm value. To deactivate the alarm all together, turn off the [RAIN AL] switch.
CALENDAR CLOCK
The calendar clock is displayed on the bottom line of the display. Use [MODE] to change among the clock, calendar and daily alarm. To set the clock, 1. Press [MODE] to display the clock or calendar. 2. Press and hold [MODE] for two seconds. 3. Use [RAIN HIST / ] or [TEMP MEM / ] to set the desired value. 4. Press [MODE] and repeat from Step 3 to complete all settings. 5. Press [MODE] to confirm. To set the daily alarm, 1. Press [MODE] to display the daily alarm. The daily alarm will be activated automatically. The daily alarm indicator will light up. 2. Press and hold [MODE] for two seconds. 3. Use [RAIN HIST / ] or [TEMP MEM / ] to set the desired value. 4. Press [MODE] and repeat from Step 3 to complete all settings. When active, the daily alarm will go off for one minute at the set time and the daily alarm indicator will flash. Press any button to stop the alarm. The alarm is still active and will go off at the set time the following day. To deactivate the function all together, turn off the [CLOCK AL] switch.
DISCONNECTED SIGNALS
If without obvious reason the display for the main unit goes blank, press [RAIN SEARCH] to enforce an immediate search. If that fails, check: - The remote rain collector is still in place. - The batteries of the main unit and rain collector are still good. Replace them if necessary. - The transmission is within range and path is clear of obstacles and interference. Shorten the distance if necessary. Then press [RAIN SEARCH] again.
INDOOR TEMPERATURE
The indoor temperature is displayed on the third line of the LCD display. Use the [C/F] switch to select between degree Centigrade and Fahrenheit. Use [TEMP MEM] to display the maximum and minimum temperatures in record. The reading will go from maximum to minimum to current and back. To clear the memory, press and hold [TEMP MEM] for two seconds. 5
THE RESET BUTTON
This button is used only when the unit is operating in an unfavorable way. Use a blunt stylus to hold down the button. All settings will return to their default values.
SPECIFICATIONS
Main unit Display rainfall range (total) : 0 - 999.99 inches (0 25,400 mm) : 0 - 99.99 inches (0 2,540 mm) : 0.04 inches (1 mm) : 23.0F to 122.0F (-5.0C to +50.0C ) : 23.0F to 122.0F (-5.0C to +50.0C ) : (0.1C) to 0.2F
PRECAUTIONS
This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Do not immerse the unit in water. 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. 4. Do not tamper with the units internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. 5. Only use fresh batteries as specified in the users manual. Do not mix new and old batteries as the old ones may leak. 6. Always read the users manual thoroughly before operating the unit.
Display rainfall range (history / daily) Rainfall resolution Display temperature range Proposed operating range Temperature resolution Remote Rain Collector Proposed operating range: General RF Transmission Frequency RF Transmission Range Temperature sensing cycle
: 33.8 F to 140.0F (1.0 C to 60.0C )
: 433 MHz : 300 feet (100 meters) : around 30 seconds
Power Main unit Remote sensing unit Weight Main unit Remote sensing unit Dimensions Main unit Remote sensing unit : 2 pcs UM-3 or AA 1.5V battery : 2 pcs UM-3 or AA 1.5V alkaline battery : 6.10 ounces (173 gm) : 9.17 ounces (260 gm) : 5.24 x 3.54 x 0.98 inches (133 x 90 x 25mm) : Dia 5.51x5.71 inches (140 x 145mm)
NOTE ON COMPLIANCE
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operations. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the users authority to operate the equipment. FCC : NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer of an experienced radio/TV technician 7
CUSTOMER ASSISTANCE
Should you require assistance regarding this product and its operation, please contact our customer care department at 800-853-8883 or via email at helpme@oscientific.com.
WARRANTY
This product is warranted to be free of manufacturing defects for a period of 3 months from date of retail purchase. Defective product should be directed to the place of retail purchase for exchange. Should this not be possible, contact our customer care department for assistance and a return material authorization. No returns may be made without a return authorization. Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased. This warranty does not cover product subjected to abuse, misuse, accidental damage or tampering.
CAUTION
The content of this manual is subject to change without further notice. Due to printing limitation, the displays shown in this manual may differ from the actual display. The contents of this manual may not be reproduced without the permission of the manufacturer.
for help. Company Name: Oregon Scientific, Inc. Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA Telephone Number: 1-800-853-8883
MODEL: RGR122
REMOTE RAIN GAUGE
Instruction Manual **** Mode D'emploi **** Bedienungsanleitung **** Manuale di Istruzioni **** Instrucciones de Funcionamiento

REMOTE RAIN GAUGE MODEL: RGR122 USERS MANUAL
INTRODUCTION
Congratulations on your purchasing the RGR122 Remote Rain Gauge. The rain gauge is equipped with the following functions: - Daily and total rainfall display - Nine-day rainfall history - Rainfall alarm - Indoor temperature display - Maximum and minimum temperatures - Real-time calendar clock - Daily alarm - 100-meter transmission range The RGR122 operates at 433MHz. No wire installation is required.
MAIN FEATURES: MAIN UNIT
A. FOUR-LINE DISPLAY - For displaying the total rainfall, current rainfall or rainfall history, indoor temperature and calendar clock B. RAIN RESET / SINCE BUTTON - Displays the start day for total rainfall - Presses and hold to clear the total and current rainfall, but not the rainfall history - Presses and hold to reset the date stamp C. RAIN SEARCH BUTTON - Enforces a search for the rain gauge sensor D. MODE BUTTON - Changes among the clock, calendar and daily alarm in normal mode - Presses and hold to enter the setting mode E. TEMP MEM BUTTON [ ] - Changes among the maximum, minimum and current indoor temperatures in normal mode - Presses and hold to clear the temperature memory in normal mode - Decreases a value in setting mode F. RAIN HIST BUTTON [ ] - Displays the rainfall history in normal mode - Increases a value in setting mode G. RAIN ALARM [ ] BUTTON - Displays the rain alarm setting - Presses and hold to enter the rain alarm setting mode
H. ANTENNA - Receives radio signal from rain collector I. [C/F] SWITCH - Selects between degree Centigrade (C) and Fahrenheit (F) J. [in/mm] SWITCH - Selects between inch and millimeter K. RAIN AL ON / OFF SWITCH - Turns on or off the rainfall alarm L. RESET BUTTON - Returns all settings to their default values M. CLOCK AL ON / OFF SWITCH - Turns on or off the daily alarm N. BATTERY COMPARTMENT - Accommodates two UM-3 or AA-sized batteries O. REMOVABLE TABLE STAND - For securing the main unit on a flat surface
MAIN FEATURE: RAIN COLLECTOR
INSTALLATION
1. Position the main unit and rain collector within effective range (100 meters). 2. a) Insert batteries into the rain collector.
TOP VIEW
b) Mount the rain collector on a level surface c) Put drops of water on the cross at the base to check the leveling
Water stay at position 1 - 4 means the gauge is not leveled
d) Use the metal ring to adjust the leveling of the rain collector P. Q. R. ANTENNA Transmits radio signal to main unit CROSS Checks the leveling of the rain collector BATTERYCOMPARTMENT Accommodates two UM-3 or AA-sized batteries 3
"AA" UM3 1.5 V
"AA" UM3 1.5V
METAL RING
3. Remove the fiber tape from around the bucket assemblies.
CALENDAR CLOCK
The calendar clock is displayed on the bottom line of the display. Use [MODE] to change among the clock, calendar and daily alarm. To set the clock, 1. Press [MODE] to display the clock or calendar. 2. Press and hold [MODE] for two seconds.
4. Insert batteries into the main unit.
3. Use [RAIN HIST / ] or [TEMP MEM / ] to set the desired value. 4. Press [MODE] and repeat from Step 3 to complete all settings. 5. Press [MODE] to confirm. To set the daily alarm, 1. Press [MODE] to display the daily alarm. 2. Press and hold [MODE] for two seconds.
5. Press the [RESET] button on the main unit to initiate operation. 6. Set the calendar and clock. 7. Press [RAIN RESET / SINCE] to display the date stamp. Press and hold to reset the date stamp to current date. Note : Every time the battery in the main unit is changed, repeat installation step 4 to 7 before use.
3. Use [RAIN HIST / ] or [TEMP MEM / ] to set the desired value. 4. Press [MODE] and repeat from Step 3 to complete all settings. 5. Press [MODE] to confirm. Press [CLOCK ALARM ON /OFF] to turn clock alarm on. The daily alarm will be activated. The daily alarm indicator will light up. When active, the daily alarm will go off for one minute at the set time and the daily alarm indicator will flash. Press any button to stop the alarm. The alarm is still active and will go off at the set time the following day. To deactivate the function all together, turn off the [CLOCK AL] switch.
LOW BATTERY WARNING
There are two low-battery indicators, one appears on the total rainfall display section and one on the indoor temperature display section. The former represents the batteries of the remote rain collector, the latter those of the main unit. Replace the batteries immediately when the respective indicator lights up. 4
TOTAL RAINFALL
The total rainfall is displayed on the top line of the LCD display. To display the commencing date of the record, press [RAIN RESET/ SINCE] once. The date will appear on the bottom line of the display. To clear the record, hold [RAIN RESET/SINCE] for two seconds. Note that this will also clear the current (Day 0) rainfall.
To clear the current day rainfall, hold [RAIN RESET/SINCE] for two seconds. Note that this will also clear the total rainfall record. Note : If HHH is observed on current (day 0) rainfall. Please press and hold [RAIN RESET / SINCE] to reset the reading in order to avoid misleading display on the total rainfall. Caution : The rainfall reading may be influenced by other sensor using the 433 MHz transmission frequency. Please avoid getting those sensors too close to the unit.
RAINFALL HISTORY
The rainfall history is displayed on the second line of the LCD display. The main unit can record up to nine days of rainfall. Use [RAIN HIST / ] to display the record for a particular day. The day of the record will be displayed with a minus (-) sign. Zero (0) means the record is for the current day.
Example :
1/2 2/2 3/2 4/1
Commenciy date of the record (the date battery is replaced or reset the total rainfall) show on the last line of display with "SINCE" by pressing [RAIN RESET /SINCE]
6/2 7/2 8/2 9/2 10/2 11/2 12/2 13/2 14/2 15/0 -0 -0 -2 -1 -0 -1 -0 -0 -0 0
CALENDAR DAY TOTAL RAINFALL (mm) RAINFALL (mm) DAY (show on screen) CURRENT DAY
-14 -13 -12 -11 -10
Running daily rainfall history shown on screen (10 days record including current day)
RAINFALL ALARM
To set the rainfall alarm, 1. Press and hold [RAIN ALARM] for two seconds. 2. Use [RAIN HIST / ] to increase the setting or [TEMP MEM / ] to decrease the setting. 3. Press [RAIN ALARM] to confirm. Press [RAIN ALARM ON/ OFF] to turn rain alarm on. The alarm will be activated. The rain alarm indicator will light up. The alarm will go off for one minute when the rainfall reaches the preset value and the rain alarm indicator will flash. A reminder beep will be emitted every minute. Once the rain alarm is on the indicator will not stop flashing unless [RAIN AL] switch is turned off or the rain alarm value is reset or normally pass to next day. To stop the alarm and reminder beep, press any button or reset the rainfall alarm value. To deactivate the alarm all together, turn off the [RAIN AL] switch.
INDOOR TEMPERATURE
The indoor temperature is displayed on the third line of the LCD display. Use the [C/F] switch to select between degree Centigrade and Fahrenheit. Use [TEMP MEM] to display the maximum and minimum temperatures in record. The reading will go from maximum to minimum to current and back. To clear the memory, press and hold [TEMP MEM] for two seconds.
THE RESET BUTTON
This button is used only when the unit is operating in an unfavorable way. Use a blunt stylus to hold down the button. All settings will return to their default values.
PRECAUTIONS
This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Do not immerse the unit in water. 2. Do not clean the unit with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts. 4. Do not tamper with the units internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts. 6
DISCONNECTED SIGNALS
If without obvious reason the display for the main unit goes blank, press [RAIN SEARCH] to enforce an immediate search. If that fails, check: - The remote rain collector is still in place. - The batteries of the main unit and rain collector are still good. Replace them if necessary. - The transmission is within range and path is clear of obstacles and interference. Shorten the distance if necessary. Then press [RAIN SEARCH] again.
5. Only use fresh batteries as specified in the users manual. Do not mix new and old batteries as the old ones may leak. 6. Always read the users manual thoroughly before operating the unit.
Power Main unit Remote sensing unit Weight Main unit Remote sensing unit Dimensions Main unit Remote sensing unit
: 2 pcs UM-3 or AA 1.5V alkaline battery : 2 pcs UM-3 or AA 1.5V alkaline battery : 173 gm : 260 gm
SPECIFICATIONS
Main unit Display rainfall range (total) Display rainfall range (history / daily) Rainfall resolution Display temperature range Proposed operating range Temperature resolution Remote Rain Collector Proposed operating range: : 0 25,400 mm (0 - 999.99 inch) : 0 2,540 mm (0 - 99.99 inch) : 1 mm (0.04 inch) : -5.0C to +50.0C (23.0F to 122.0F) : -5.0C to +50.0C (23.0F to 122.0F) : 0.1C to (0.2F)
: 133(142) x 90 x 25 mm : Dia 140 x 145 mm
CAUTION
The content of this manual is subject to change without further notice. Due to printing limitation, the displays shown in this manual may differ from the actual display. The contents of this manual may not be reproduced without the permission of the manufacturer.
1.0 C to 60.0C ( 33.8 F to 140.0F)
General RF Transmission Frequency RF Transmission Range Temperature sensing cycle
: 433 MHz : 100 meters : around 30 seconds
EC-DECLARATION OF CONFORMITY
This product contains the approved transmitter module TX 02 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC Directives, if used for its intended use and that the following standard(s) has/have been applied: Efficient use of radio frequency spectrum (Article 3.2 of the R&TTE Directive) applied standard(s) Electromagnetic compatibility (Article 3.1.b of the R&TTE Directive) applied standard(s) Safety of information technology equipment (Article 3.1.a of the R&TTE directive) applied standard(s) EN 60950:1997 ETS 300 683:1997 EN 300 220-1(2,3):1997
Additional information: The product is therefore conform with the Low Voltage Directive 73/23/EC, the EMC Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the respective CE marking.
VS-Villingen / Germany August 2001 Gerhard Preis R&TTE Representative of manufacturer
RTTE Compliant Countries : All EC countries, Switzerland CH , Germany D , Austria A , France F and Netherlands NL
MODEL: RGR122
REMOTE RAIN GAUGE
Instruction Manual **** Mode D'emploi **** Bedienungsanleitung **** Manuale di Istruzioni **** Instrucciones de Funcionamiento
Tags
D3122 Samsung S850 Fujifilm A230 32PW8506 12R Digimaxl60 MD-MT20 DCP-8060 Review LXE990 HD7400 LF450 Commander 2002 IP6700D EW879F TX-SA806X HS 10 VGP-prfs1 GE-940 USR5450 Rt4MD 50PF9966 Grandprix 2000 DSP-Z11 V70 R SGA 4100 AV-21JT5EU 2 0 CA-40 TL-WN827N SB-246 Square PRO Roland E-60 P-334 DAP-1160 HDR-CX305E Pcvasp4 SCH-A950 Twinset Navara IR6880C QW14790 TXP42GT20E Mcmd-R1 1 0 Server EDC77570W 96850 SRS-Z1000 Rifle LAC-M6600 JR 2006 Conquest T1954 Laserjet 3800 TLX-01911C KDC-W413U Ironhide 957MB RM185R Client CDX-434RF CT-S550S VL-NZ10 Printer WET11 SMH5140WB SH13ST Enduro 8 HD3U-40 SGH-X461 SU-VZ220 RDC-2 LE46B750 DTH8045E TX-15AT1 GC9040 BE-300 Mcd700 S-GPS FAX-515 Essen CD31 KAC-921 D845WN Makita 1902 Grandtour Nd-XX 42PFL7603D 47LB5DF Locator DAV-DZ556KB YST-FSW150-050 9970G V1812W Profile MF5770 ZDF212 Favor 119213C EOB53000X LE32R41BD Windoo
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101

1. Oregon Scientific Cable Free Long Range Rain Gauge
2. Oregon Scientific RGR126 Cable Free Long Range Rain Gauge
3. Oregon Scientific THGR122NX Wireless Temperature and Humidity Sensor