Reviews & Opinions
Independent and trusted. Read before buy Panasonic WV-CU360!

Panasonic WV-CU360


Bookmark
Panasonic WV-CU360

Bookmark and Share

 

Panasonic WV-CU360About Panasonic WV-CU360
Here you can find all about Panasonic WV-CU360 like manual and other informations. For example: review.

Panasonic WV-CU360 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Panasonic WV-CU360 please write about it to help other people.
[ Report abuse or wrong photo | Share your Panasonic WV-CU360 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Panasonic WV-CU360, size: 521 KB
Related manuals
Panasonic WV-CU360C

 

Panasonic WV-CU360

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 1. Page 1 of 1. Average Rating:
joy lindsey 6:09am on Sunday, October 17th, 2010 
Handle for easy carrying, sleek, executive looking black color, widescreen Handle blocking the latch from opening.

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

System Controller

WV-CU360
RISQUE DE CHOCS ELECTROUES NE PAS OUVRIR

CONTROLLER No. MODE

Setting the Controller Number
Controller Number Switch of WV-CU9

Key Features

The WV-CU360 System Controller enables the following key functions.
Selection the camera Alarm (Data/Display/Resume/Suspend/Recall/Reset) Setup menu
Remote control of the Panasonic dome camera series via PS Data Link mode through WJ-MP204.
Camera functions: Super Dynamic II /Electronic Shutter/Electronic Sensitivity/Automatic Gain Control/Site Alarm Lens function: Iris/Focus/Auto Focus/Zoom Housing: Defroster/Wiper/Auxiliary 1,2 Pan/Tilt: Boost Pan/Boost Tilt/Auto Pan/Auto Sort/Auto Sequence/ Random Pan/Preset/Home

DIP Switch Setting

OFF ON
Remote control of the WJ-FS309/WJ-FS316 Video Multiplexers via Panasonic Security (PS) Data Link mode.
Multiscreen/Multiscreen Sequence/Multiscreen Sequence Stop/ Multiscreen Pause/Multiscreen Backward Sequence/Multiscreen Forward Sequence/Forward step/Reverse step/Display Mode (Multiscreen/Still)/Monitor Selection
Dip Switch (1)(2): Used to set the Panasonic Security Data mode. Dip Switch (3): As reserve. Dip Switch (4): As reserve. Dip Switch (5): Used to set the termination. Dip Switch (6): Used to appear Setup menu for PanasonicSecurity Data mode. Dip Switch (7): Used to set the Baud Rate setting.
ON : 19,200 bps OFF : Baud Rate is selected 19,200, 9,600, 4,800, or 2,400 bps automatically. Dip Switch (8): Used to specify the transmission mode.
The Panasonic WV-CU360 System Controller is designed to control the optional WJ-MP204 Data Multiplex Unit or the WJ-FS309/WJ-FS316 Video Multiplexers. The WV-CU360 System Controller enables control of the Cameras, Lenses, Electric Zoom, Auto Focus, boost Pan/Tilt Heads, selection of the cameras by Numeric buttons through with the WJ-MP204 Data Multiplex Unit. The WV-CU360 System Controller, enables set Two-type of passwords, Login and Set-up menu. The WV-CU360 is highly advanced video surveillance system controller, with deliver optimum performance at a competitive cost.

Rear View

1. Controller Number switch 2. Mode Selection switches 3. Data Ports 4. DC 9V Input Jack
RISK OF ELECTRIC SHOCK. DO NOT OPEN

DC 9V IN

Unit Number As reserve As reserve

SYSTEM EXAMPLE

Camera (4) Camera (5) Camera (2) Camera (6) Camera (1)

Camera (7) Camera (8)

WJ-MP204

Camera (3)

Video Monitor
daisy chain connector (option)

Multi screen

Camera (9)

CAMERA SELECT

ALARM ALARM RESET SPOT MULTISCREEN MULTI SCREEN SERECT VTR STILL EL-ZOOM

MENU CAM

Simplex

Camera (16)

ESC Video Multiplexer WJ-FS
Panasonic Security Data Link

WJ-FS316 Time Lapse VCR

MAJOR OPERATING CONTROLS

OPERATE

SETUP FUNCTION

MONITOR UNIT

CAMERA

PROHIBITED

System Controller WV-CU
IRIS CLOSE OPEN IRIS RESET SX NEAR FOCUS FAR AUTO FOCUS L FS ZOOM WIDE TELE R UP

SHIFT ALM RESET

CAM SETUP ALM RECALL

CAM FUNCTION HOME

ALM SUSPEND VCR CAM MULTI SCREEN SELECT

B/W DEF

AUX 2 STILL EL-ZOOM WIPER
DOWN 1 CAM/DEC +1 CAM/INC SEQ PAUSE SEQUENCE AUX 1 AUTO MON CAM PRESET POSI

PATROL STOP

PATROL

LOGOUT

For PS Data
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
Operate indicator Login indicator Alarm indicator Monitor/Unit indicator LED Display Busy indicator Prohibited indicator Joystick Controller Iris buttons Focus buttons Zoom buttons
12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22.
SX/Unit button FS button Preset Position button Numeric buttons Camera/Set button Log Out button Monitor/Escape button Function/Cam Function button Setup/Camera Setup button Shift button Home/Black and White button
23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33.
Defroster/Auxiliary 2 button Wiper/Auxiliary 1 button Auto/Camera Patrol button Alarm Recall button Alarm Reset/Alarm Suspend button Multiscreen Monitor button VCR/Camera Selection button Electronic Zoom/+1 Camera Increment button Still/-1 Camera Decrement button Sequence/Patrol Stop button Sequence Pause/Step button

SPECIFICATIONS

9V DC, 400mA Use only AC Adapter model CU360D269P Power Consumption 10W Data Output/Input Port 6-conductor modular jack (RS-485, Full Duplex) Switching Functions (WJ-MP204) Selection the Camera Switching Functions Multiscreen/Multiscreen Sequence/Multiscreen Sequence Stop/Multiscreen [WJ-FS309 (WJ-FS316)] Pause/Multiscreen Backward Sequence/Multiscreen Forward Sequence/ Forward step/Reverse step Display Mode: (Multiscreen/Still) Monitor Selection Unit address 1-8 Camera Functions Super Dynamic II On/Off Electronic Shutter: On/Off, Increment/Decrement Electronic Sensitivity: On/Off, Increment/Decrement Automatic Gain Control: On/Off Site Alarm (Motion Detector): On/Off Site Alarm (Motion Detector) Display Mode: On/Off Lens Functions Iris: Open/Close/Preset (only with DC control lens) Focus: Near/Far/Auto Focus Auto Focus: Activate Zoom: Wide/Tele Housing Defroster: On/Off Wiper: On/Off Auxiliary 1: On/Off Auxiliary 2: On/Off Pan/Tilt Manual Pan (Boost): Right/Left, Manual Tilt (Boost): Up/Down Auto Pan On, Auto Sort On, Auto Sequence, Random Pan On, Preset, Home Operating for System Selection the Camera Alarm (Data/Display/Resume/Suspend/Recall/Reset), Setup Camera, Lens, Housing, PAN/TILT, External device control Ambient Operating Temperature 14F - 140F (-10C - +50C) Ambient Operating Humidity Less than 90% 300 (W) x 74 (H) x 177 (D) mm [11-13/16" (W) x 2-15/16" (H) x 6-15/16" (D)] Dimensions Weight 1.3kg (2.9 lbs.) AC Adapter.1pc 6-conductor Modular Cable Assembly.1pc Power Source

APPEARANCE

2-15/1

6" (74

2-3/4" (70)

6-15/16" (177)

11-13/16" (300)

Unit: inches (mm)

Weights and dimensions are approximate. Specifications are subject to change without notice. These products may be subject to export control regulations.

DISTRIBUTED BY:

Panasonic Security & Digital Imaging Company
A Division of Matsushita Electric Corporation of America

Security Systems Group

Executive Office : One Panasonic Way 3E7, Secaucus, New Jersey 07094 Regional Office Northeast : One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern : 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest : 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western : 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840 PANASONIC CANADA INC. 5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905) 624-5010 PANASONIC SALES COMPANY DIVISION OF MATSUSHITA ELECTRIC OF PUERTO RICO, INC. San Gabriel Industrial Park 65th Infantry Ave. KM. 9.5 Carolina, P.R. 00985 (809) 750-4300
Printed in Japan [2P-468]

doc1

System Controller

Operating Instructions

Model No.

WV-CU360
OPER ATE LOGI N ALAR M MON UNIT ITOR
SHIF T ALM RES ET FUN CTIO N SUSP END

SETU P

PRO GRAM CAM SETU P CAM FUN CTIO N AUTO

CAM ERA BUSY PROH IBITED

MULT I SCRE EN SE LECT

CAM B /W DEF

EL-ZO O

SE IRIS

troller
SEQ PAU SE SEQ SLO W PATR STO OL P PATR LEAR OL N UEN

AUX 2 WIP ER

UNIT A NEA R

OPE RESE T

CE PATR

FOC US

OL PL AY MON

ESC LOG

UNIT B

OUT SET

HOM E/PR ESET

PRO G PRES RAM ET

Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
Caution: Before attempting to connect or operate this product, please read the label on the bottom.

For U.S.A

CAUTION
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. FCC Caution: To assure continued compliance, (example use only shielded interface cables when connecting to computer or peripheral devices). Any changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate this equipment.

SA 1965

The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
The serial number of this product may be found on the bottom of the unit. You should note the serial number of this unit in the space provided and retain this book as a permanent record of your purchase to aid identification in the event of theft. Model No. Serial No. WV-CU360
SA 1966 WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or moisture.

CONTENTS

PREFACE...... 4 FEATURES..... 4 PRECAUTIONS...... 4 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS.... 5 s Front View...... 5 s Rear View..... 8 BASIC OPERATING FLOW..... 9 INSTALLATIONS..... 10 s Dip Switch Setting...... 10 SETUP...... 11 s Setup Procedures..... 11 KEY FUNCTIONS OF SETUP MENU..... 11 SETUP MENU...... 12 s Setup Menu...... 12 s Displaying the Setup Menu..... 12 SYSTEM CONNECTIONS..... 14 s Connections to the WJ-MP204 Data Multiplex Units and the WJ-FS309 (WJ-FS316) Video Multiplexer.. 14 s Connections with the AC Adapter..... 14 s Connections in Panasonic Security Data Mode.... 15 OPERATING PROCEDURES..... 16 LOG IN/LOG OUT..... 16 s LOG IN...... 16 s LOG OUT..... 16 SYSTEM SELECTION...... 17 s System Unit Selection..... 17 s Monitor Selection..... 18 s Camera Selection..... 18 CONTROLLING SYSTEM FUNCTIONS..... 19 CAMERA CONTROL FUNCTIONS..... 21 s Pan/Tilt Control...... 21 s Lens Control..... 21 s Operation of Combination Camera..... 21 s Camera Housing Control..... 25 s External Device Control..... 25 ALARM CONTROL FUNCTIONS..... 26 s Alarm Operation...... 26 s Alarm Reset...... 26 s Alarm Suspend...... 26 s Alarm Recall..... 26 ALL RESET...... 26 SYSTEM UNIT AND CAMERA SETUP..... 27 SPECIFICATIONS...... 30 STANDARD ACCESSORIES..... 31

!7 Monitor/Escape button (MON/ESC) MON: Used for monitor selection and confirmation. To select a monitor, enter the desired Monitor number with the Numeric keys, and then press this button. The selected monitor number appears on the LED display. To confirm a monitor number, simply this button. ESC: This button is used to escape from the currently highlighted selection and return to the previous menu of the Setup Menu. Pressing this button together with the CAM/SET button for approximately 2 seconds will log out from the system. !8 Program/Camera Setup/Camera Function button (PROGRAM/CAM SETUP/CAM FUNCTION) Pressing this button for 2 seconds or more will open the camera setup menu. Pressing it in combination with the Numeric buttons after pressing the Shift button will execute camera functions. The LED next to the button is lit during the camera setup operation. This button is used to program camera patrol learning and preset position functions. !9 Setup/Function button (SETUP/FUNCTION) Pressing this button for 2 seconds or more will open the Setup menu of system unit. Pressing it after pressing the Shift button will function the system unit in combination with the Numeric buttons. The LED next to the button is lit during the setup operation. @0 Shift button (SHIFT) Pressing this button in combination with buttons to which special functions have been assigned will activate these functions. The LED next to the button is lit when the button is pressed. The LED next to the button is gone off when the button is pressed again. @1 Auto Panning/Black and White button (AUTO/B/W) Pressing this button will activate the auto panning function of cameras provided with this feature. Pressing it after pressing the Shift button will display the picture which changed to a black and white picture on the monitor. AUTO PAN ON or Functions that is set in combination camera: Simply press this button, or press Numerc button 1 followed by this button. AUTO SORT ON: Press Numeric button 2 followed by this button. AUTO SEQ ON: Press Numeric button 3 followed by this button. RANDOM PAN ON: Press Numeric button 4 followed by this button.
@2 Defroster/Auxiliary 2 button (DEF/AUX 2) Pressing this button will activate the housing defroster of cameras provided with this feature. Pressing it after pressing the Shift button will turn on the AUX2 button controlling accessories connected to the cameras or the system. The LED next to the button is lit while the defroster or AUX2 mode is selected. @3 Wiper/Auxiliary 1 button (WIPER/AUX 1) Pressing this button will activate the housing wiper of cameras provided with this feature. Pressing it after pressing the Shift button will turn on the AUX1 button controlling accessories connected to the cameras or the system. The LED next to the button is lit while the wiper or AUX1 mode is selected. @4 Patrol Play/Patrol Learn button (PATROL PLAY/ PATROL LEARN) Pressing this button will turn on the camera patrol play function. Pressing this button while holding down the Program/Camera setup/Camera function button, will start to program the camera patrol learning function. @5 Alarm Suspend button (ALM SUSPEND) Pressing this button will activate the alarm suspension mode (alarm input is ignored). The LED next to the button is lit while alarm suspension mode is selected. @6 Alarm Reset/Alarm Recall button (ALM RESET/ALM RECALL) Pressing this button while the alarm function is activated will reset the alarm of the system. Pressing this button after pressing the shift button will recall the alarm logs (record of alarms activated in the past). Select a monitor, and then press this button to display the alarm logs on the monitor screen. Pressing the button after pressing the shift button again will cancel the function. The LED next to the button is lit while Alarm Recall mode is activated. @7 Multiscreen Selection button (MULTI SCREEN SELECT) This button is used to operate the multiscreen monitor connected to the MULTISCREEN OUT connector of the Video Multiplexer. Note: The above operation in not available unless a multiscreen monitor is selected. @8 VCR/Camera Selection button ( VCR/ CAM) Selects to confirm VCR playback picture for display on the multiscreen monitor. The LED next to the button is lit while VCR mode is selected.

s Displaying the Setup Menu
1. Check that DIP Switch 6 is set to ON (Administrator mode). 2. Connect the DC plug to the DC 9V IN jack and the AC adapter to an AC outlet. The power of WV-CU360 is supplied. 3. Check that the cameras and the other units are connected correctly and securely. 4. Switch the cameras and other system units on. 5. [SEtUP] appears. 6. Press the CAM/SET button. [ ] appears blinking. 7. Enter the Administrator Password. The default is [12345]. Then press the CAM/SET button. [SPEEd] appears. 8. You can proceed to another setting menu by moving the joystick up or down. 9. Press the CAM/SET button. The existing settings appear. 10. To change a parameter, press the CAM/SET button after confirming the existing settings. For details on changing the settings, see the corresponding parts of this page and the next. 11. Select a parameter by entering a number using numeric buttons, by moving the joystick to the left or right, or by pressing STILL/- button or EL ZOOM/+ button. 12. Press the CAM/SET button to set the entry. The set value appears on the LED display. The set data is saved in the memory of the WV-CU360. The setting is completed. To return to the previous menu, press MON/ESC button. To set another parameter, repeat procedures 8 to 12. 13. After disconnect the AC adapter from the AC outlet, set Dip Switch 6 back to OFF (Operator mode). Notes: If the administrator password fails in obtaining authorization, [Error] appears blinking for 2 seconds on the LED display, followed by [SEtUP]. After DIP Switch 6 is set to OFF (Operator mode), the
q Parity Check Setting (02)
1. 2. 3. 4. Select [Prty] by moving the joystick up or down. Press the CAM/SET button. [Pr-n] appears. Press the CAM/SET button. Enter 1 (n) or 2 (E) using numeric buttons. Or, select the desired parity check n (NONE) or E (EVEN) by moving the joystick to the left or right. The initial factory setting is NONE. 5. Press the CAM/SET button. 6. To return to [Prty], press MON/ESC button. Note: The desired parameter is also selected by pressing STILL/ button or EL-ZOOM/+ button.

q Wait Time Setting (03)

1. 2. 3. 4. Select [WAIt] by moving the joystick up or down. Press the CAM/SET button. [oFF] appears. Press the CAM/SET button. Enter 1 (OFF), 2 (100), 3 (200), 4 (400), or 5 (1000) using numeric buttons. Or, select the desired wait time 100, 200, 400, or 1000 ms by moving the joystick to the left or right. The initial factory setting is OFF (No retry). 5. Press the CAM/SET button. 6. To return to [WAIt], press MON/ESC button. Note: The desired parameter is also selected by pressing STILL/ button or EL-ZOOM+ button.

q User Password Setting (08)
1. Select [USrP] by moving the joystick up or down. 2. Press the CAM/SET button. [12345] appears. 3. Enter a 5-digit (00000 to 99999) using numeric buttons. The LED blinks. The initial factory setting is [12345]. 4. Press the CAM/SET button. The LED stops to blink. 5. To return to [USrP], press the MON/ESC button. Note: If a 5-digit is not entered, the setting is invalid.
q Unit Connection Test Setting (12)
Check that the power of the cameras and the other units are switched on. 1. Select [UtESt] by moving the joystick up or down. 2. Press the CAM/SET button. [01-on] or [01-oF] appears. 3. Press the CAM/SET button. The unit connection test starts (01-99). 4. The LED display shows a two-digit unit addresses on the left and a two-digit animations for testing on the right. 5. The last unit address appears when the unit test is over. 6. Press the CAM/SET button. 7. If you enter the unit address using numeric buttons after finished it, you can confirm whether the unit is connected or not. Enter a 2-digit unit address to confirm the connection. When [**-on] appears, the unit is connected. When [**-oF] (OFF) appears, the unit is not connected. 8. To return to the previous display, press the MON/ESC button. Notes: [**] displays the selected unit address (01-99) To cancel the unit connection test, press the MON/ESC button. Camera surveillance is disabled while the unit connection test continues.
q Administrator (Super User) Password Setting (09)
1. Select [SUSrP] by moving the joystick up or down. 2. Press the CAM/SET button. [12345] appears. 3. Enter a 5-digit (00000 to 99999) using numeric buttons. The LED blinks. The initial factory setting is [12345]. 4. Press the CAM/SET button. The LED stops to blink. 5. To return to [SUSrP], press the MON/ESC button. Note: If a 5-digit is not entered, the setting is invalid.
q User Authorization(Certification)Setting(10)
1. 2. 3. 4. Select [USr-C] by moving the joystick up or down. Press the CAM/SET button. [UC-on] appears. Press the CAM/SET button Enter 2 (User Certification ON) or 1 (User Certification OFF) using Numeric buttons. Or, select User

SYSTEM CONNECTIONS

s Connection to the WJ-MP204 Data Multiplex Units and the WJ-FS309 (or WJFS316) Video Multiplexer (Panasonic Security Data Mode)

The supplied 6-conductor cable permits easy connection by simply plugging it into the data port (DATA) of the WJ-MP204 Data Multiplex Unit(s) and the other end into one end of the same port (DATA) of the System Controller. If you are using locally purchased cables, make sure that they are 2-wire twisted pair shielded cables of data grade suited to the RS-485. Low-grade cables will cause instability of system operation.
Camera No. 4 Camera No. 5

Camera No. 1

Camera No. 2 Camera No. 6 Camera No. 3 Camera No. 7

Camera No. 8

VS/VD INPUT

VS/VD OUTPUT

Unit Address 2
IN IN IN A L A R M / R E M OT E IN IN IN

Unit Address 1

A L A R M / R E M OT E

T R A B A

SIGNAL GND

WJ-MP204

SD B A

RD B A

DATA MODE

3 CAMERA

1 SPOT

OUT VS/VD

OUT RS485 DATA MODE

OUT RS485

MODE 4-Line Termination OFF Panasonic Security Data mode
4-Line Termination ON Panasonic Security Data mode VD OUT

Monitor No. 1 WJ-FS316

IN ALARM/REMOTE OUT DATA CAMERA SW IN
Controller No.1 Termination ON (See page 10.) System Controller WV-CU360

8 VIDEO

1 PLAY IN

MULTI REC OUT SCREEN OUT

SPOT OUT

Unit Address 3

Branch Connector Monitor No. 2
s Connection with the AC Adapter
Insert the DC plug of the supplied AC adapter into the DC 9V input jack (DC 9V IN) on the System Controller. Then, plug the AC adapter into an AC outlet.
s Connection in Panasonic Security Data Mode

q Basic Connection

Connect one of the DATA port on the System Controller to the same port on the WJ-MP204 with the supplied RS-485 cable (a standard accessory to the system controller).
Data Multiplex Unit WJ-MP204 System Controller WV-CU360
q Loop-through Connection
1. Plug the branch cable (optional accessory) into the DATA jack on the Video Multiplexer WJ-FS309 (or WJ-FS316). 2. Connect one end of the branch cable from the DATA port on the WJ-MP204. 3. Plug the branch cable into the DATA port on the WJ-MP204, and connect one of the DATA port on the System Controller with the RS-485 cable.
Video Multiplexer WJ-FS309 (WJ-FS316)
Data Multiplex Unit WJ-MP204
System Controller WV-CU360

Branch Cable

To use cables locally purchased, they must be of the data grade: BELDEN 9406 or equivalent. The pin assignments and data flow are shown below.

Internal Diagram

No. Name GND TX(B) TX(A) RX(B) RX(A) GND Data Flow WV-CU360 System Unit WV-CU360 System Unit WV-CU360 System Unit WV-CU360 System Unit No. 6

TX (B) TX (A)

WV-CU360 1

System Unit End

RX (B) RX (A)

OPERATING PROCEDURES

The operating instructions for using the System Controller in a system are described below. For further information, refer to the Operating Instructions for the camera and for the individual system units.

LOGIN/LOGOUT

User authorization with password input is necessary for access to the system controller. If [User Certification OFF] is selected in the user authorization (certification) setting, password input is not necessary because the system controller is automatically ready for operation when the power is turned on.

SET SET

s LOG IN
1. Insert the DC plug into the DC 9V IN jack and connect the AC adapter to an AC outlet.

Blinks

2. The controller number, software version, and [LogIn] appears in order on the LED display. 3. Press the CAM/SET button. 4. Enter a 5-digit user password with the Numeric buttons. The password appears as each [-] digit. Initial factory setting is [12345] (See page 13). 5. Press the CAM/SET button. 6. If the user password is successfully entered for user authorization, LOGIN indicator lights up. The unit that is assigned to the UNIT A/UNIT button as number 1 is selected automatically. If its entry has failed, [Error] appears on the display. The display returns to [Login].

s LOG OUT

1. Press the MON/ESC and CAM/SET buttons for about 2 seconds simultaneously. 2. [Login] appears on the display and the LOGIN indicator goes off. 3. Disconnect the DC plug from the DC 9V IN jack and the AC adapter from the AC outlet. Note: If power remains on after finishing logout, the alarm indicator and alarm suspend indicator keep indicating the present system mode. The alarm indicator blinks in case of an alarm is activated after finishing logout. It changes to steady light when the alarm is automatically reset.

SYSTEM SELECTION

s System Unit Selection
The following function is available only when connected to System Units. There are two ways of system unit selection. One is to enter unit address using numeric buttons and the other is to select a system unit by pressing the UNIT A/UNIT or UNIT B button.
q Unit A/UNIT Button or UNIT B Button Selection
The UNIT A/UNIT button or UNIT B button can be assigned each till nine system units using Numeric buttons. These buttons can be assigned to system units using the Setup menu (See page 13). If two or more system units are connected, the desired one can be selected by pressing the corresponding numeric button, then press the UNIT A/UNIT button or UNIT B button. 1. Enter an UNIT A or UNIT B number using numeric buttons. This operation can be omitted if you select the unit assigned to UNIT A number 1 or UNIT B number 1.

q Unit Selection

1. Check the unit number of each system unit. 2. Enter a unit number using numeric buttons.

CAM MON CAM

LOGOUT

SET ESC LOGOUT SET

3. Press the UNIT A/UNIT button after pressing the SHIFT button.

UNIT A

2. Press the UNIT A/UNIT button or the UNIT B button.

UNIT A SHIFT UNIT UNIT

The selected unit number appears in the unit section of the LED display. The selected camera number appears in the camera section of the LED display. Notes: To confirm the selected unit number when the monitor number appears in the unit section of the LED display, take procedure 3 or press MON/ESC button. If no unit is connected, [Err] appears a few seconds after unit selecting operation is performed. In such a case, repeat the above procedures after confirming the unit address. If the unit address of a system unit is unknown, consult the administrator of it.
The selected unit address appears in the unit section of the LED display. The selected camera number appears in the camera section of the LED display. Notes: In cases where the system unit is frequently used, assign the UNIT A number [UA-no] or the UNIT B number [Ub-no] (See page 13). If [A1-**] or [b1-**] is assigned to the system unit as its UNIT A or UNIT B number, it can be selected by simply taking procedure 2. [**] displays the selected unit address (01-99)

s Monitor Selection

Check that a monitor is connected to the system unit correctly and securely. 1. Select a system unit connected to the monitor. 2. Enter the monitor number using numeric buttons. A monitor number is setup each system unit for output to the monitors. For further information, refer to the Operating Instructions for the individual units.

s Camera Selection

1. To display the selected camera, select the desired system unit connected to cameras and the monitor. 2. Press the numeric buttons for the selected camera number. The camera number appears on the LED display. 3. Press the CAM/SET button to display the picture of the selected camera. The following function are available after selecting a camera. Pan/tilt Focus Zoom Iris Defroster ON/OFF (for camera housing) Wiper ON/OFF (for camera housing) Preset Position (for Combination Camera) Home position (for Combination Camera) Color or B/W picture changing function (for Combination Camera) Auto pan (for Combination Camera) Patrol Learn function (for Combination Camera) Camera functions (for Combination Camera)
3. Press the MON/ESC button. MON
ESC The selected monitor number appears in the monitor section of the LED display. And then you can control video operation for the selected monitor. The selected camera number appears in the camera section of the LED display. Notes: To confirm the selected monitor number, simply take procedure 3 when the unit address appears in the monitor section of the LED display. The display of the unit section and the monitor section of the LED display changes alternately every time the MON/ESC button is pressed. The setting is invalid if the unit in which a monitor number has been set is not programmed. In the above case, repeat the same procedure after confirming the monitor number. If you do not know the monitor number, consult the administrator of it. When [--] appears in the monitor section of the LED display, the selected system unit is not compatible with the Monitor Selection. For further information, refer to the Operating Instructions for the system unit concerned.
Note: [--] appears in the camera section of the LED display when an alarm is activated, when the multiscreen is displayed, or when sequence mode is on. The following function is available only in cases where system units with the picture change function are connected. The currently selected camera can be replaced with the camera of the next higher number by pressing the ELZOOM/+ button after pressing the SHIFT button. The currently selected camera can be replaced with the camera of the next lower number by pressing the STILL/ button after pressing the SHIFT button.
CONTROLLING SYSTEM FUNCTIONS
It is necessary to setup the system unit compatible with Panasonic Security Data mode before using system functions. For further information, refer to the Operating Instructions for the system unit. You can also setup the system unit by this controller (See page 27). The operation differs depending on the system unit.

q System Function Control
The following function is available in cases where a system unit capable of system function control with numeric buttons is connected. For further information, refer to the Operating Instructions for the system unit used. 1. Select the desired system unit and monitor. 2. Select a system function number using numeric buttons.

q Sequence Function

The following function is available only in cases where a system unit with the sequence function and sequence pause function is connected. 1. Select the desired system unit and monitor. 2. Press the SEQUENCE/PATROL STOP button. The SEQUENCE indicator lights up.

SEQUENCE

MON CAM

PATROL STOP

3. Press the SETUP/FUNCTION button after pressing the SHIFT button.
3. To pause the sequence, press the SEQ PAUSE/SLOW button.

SEQ PAUSE SHIFT SLOW

FUNCTION
4. To move the sequence one step forward, press the ELZOOM/+ button.
The system function corresponding to the entered number is controlled.

CAMERA CONTROL FUNCTIONS

It is necessary to setup the camera before using camera control funcions. For further information, refer to the Operating Instructions for the combination camera to setup (See page 27). You can also setup it in camera setup menu when you operate systems.

FOCUS FAR AUTO FOCUS

3. Press the ZOOM TELE button to optically bring the object closer, or press the ZOOM WIDE button to optically widen the scene.

ZOOM WIDE TELE

s Pan/Tilt Control
The following function is available only to a combination camera to which a pan/tilt head is connected to the system unit. 1. Select the desired system unit, monitor and camera. 2. Move the pan/tilt head in the desired direction using the joystick. The joystick can be moved in eight directions.
4. Press the IRIS CLOSE button to close the iris, or the IRIS OPEN button to open the iris. If the IRIS CLOSE and IRIS OPEN buttons are simultaneously pressed, the iris is reset to the default.
IRIS CLOSE IRIS RESET OPEN
Joystick (8-directions) UP
s Operation of Combination Camera
It is necessary to setup the combination camera before using the operation of it. For further information, refer to the Operating Instructions for the combination camera to setup (See page 27). You can setup in camera setup menu when you operate systems.
q Changing Pictures of Preset Position
The following function is available only to cameras with the preset function. The preset function make the combination camera move to the programmed preset position. It is necessary to program preset positions in the combination camera beforehand. 1. Select the desired system unit, monitor and combination camera. 2. Select a preset number using numeric buttons, and press the HOME/PRESET/PROGRAM PRESET button.

To move the pan/tilt head slow down, move the joystick while holding down the SLOW button.

SEQ PAUSE

s Lense Control
The following functions are available to combination cameras with lens control capability.

HOME/PRESET

1. Select the desired system unit, monitor and camera.
2. Press the FOCUS NEAR or FOCUS FAR button to adjust the lens focus while watching the monitor. If you are using a camera with an auto focus feature, the lens focus can be automatically adjusted by pressing the FOCUS NEAR and FOCUS FAR buttons simultaneously.

PROGRAM PRESET

The combination camera moves to the programmed preset position and the picture of the camera in that position appears on the monitor.
q Changing the Pictures of Home Position
The following function is available only to cameras with the preset function. It is necessary to program the home position in the combination camera beforehand. 1. Select a system unit, monitor and combination camera. 2. Press the HOME/PRESET/PROGRAM PRESET button to move the combination camera to the home position.
q Changing to Black and White Pictures
The following function is available to the camera with a color-black and white switching function specified for this operation. 1. Select the desired system unit, monitor and combination camera. 2. Press the AUTO/B/W button, after pressing the SHIFT button, to change from color to black and white picture. The black and white pictures appear on the monitor.

PROGRAM PRESET SHIFT B/W

The camera returns to the home position and the picture of it appears on the monitor.

q Auto Pan

The following functions are available only to the camera with a pan/tilt head specified for this operation. It is necessary to program auto pan function in the combination camera beforehand. 1. Select the desired system unit, monitor and combination camera. 2. Press the AUTO/B/W button. The auto panning activates according to the program in the combination camera. The picture appears on the monitor. The following functions differ depending on the combination camera. AUTO PAN ON or Functions that is set in combination camera: Simply press Numeric button 1 followed by this button. AUTO SORT ON: Press Numeric button 2 followed by this button. AUTO SEQ ON: Press Numeric button 3 followed by this button. RANDOM PAN ON: Press Numeric button 4 followed by this button. For further information, refer to the Operating Instructions for the combination camera.

AUTO SEQ PAUSE

3. To change black and white picture back to color, press the AUTO/B/W button again after pressing the SHIFT button. Notes: When the changing black and white picture setting is set to AUTO in the camera setup menu, this function is disabled.

q Camera Patrol Function

The following function is available in cases where a combination camera with the camera patrol function is connected. The camera patrol function enables the combination camera to learn joystick movements and zooming operation. To program the camera patrol learning function, see page 28. 1. Select the desired combination camera. 2. Press the PATROL PLAY/PATROL LEARN button to move the combination camera according to the data saved in the memory.

PATROL PLAY

PATROL LEARN
Camera patrol picture appears on the monitor.

B/W SLOW

3. To cancel auto pan, move the joystick.
3. To cancel patrol play function, move the joystick.
Electronic Shutter The following function is available only to cameras with the electronic shutter feature. 1. Select the desired combination camera.
2. Press numeric buttons 1, 7, and 1.
q Camera Cleaning Function
This function is used in cases of where the preset positions of a combination camera have deviated. The function can be set ready using the Setup menu. For further information, refer to the description of Camera Cleaning setting in the Setup menu. (See page 13.)

q Camera Functions

For further information, refer to the Operating Instructions for the camera. Examples of camera functions are described as follows. Super DynamicII The following function is available only to cameras with the Super DynamicII function.
3. Press the CAM SETUP/CAM FUNCTION button after pressing the SHIFT button.

CAM SETUP

CAM FUNCTION
1. Select the desired combination camera. 2. Press the numeric button 8 and 4. 4. To cancel the electronic shutter function, press numeric buttons 1, 7 and 2 in procedure 2 above. 5. To increase electronic shutter speed, press numeric buttons 1, 7 and 3 in procedure 2 above. 6. To decrease electronic shutter speed, press numeric buttons 1, 7 and 4 in procedure 2 above.
4. To cancel the Super DynamicII function, press numeric buttons 8 and 5 in procedure 2 above.
Automatic Gain Control The following function is available only to cameras with the AGC feature. 1. Select the desired combination camera. 2. Press numeric buttons 1, 7 and 5.
4. To cancel the electronic sensitivity function, press numeric buttons 1, 7 and 8 in procedure 2 above. 5. To increase electronic sensitivity, press numeric buttons 1, 7 and 9 in procedure 2 above. 6. To decrease electronic sensitivity, press numeric buttons 1, 8 and 0 in procedure 2 above.

ALARM CONTROL FUNCTIONS

s Alarm Operation
When the WV-CU360 receives an alarm signal from a system unit, the alarm indicator blinks. The alarm indicator changes from blinking to steady light when the alarm is automatically reset. The camera number [---] appears in the camera section of the LED display.
Input alarm is ignored even after the ALM SUSPEND is set.

ALM SUSPEND

2. To cancel the alarm suspend function, press the ALM SUSPEND button again.

s Alarm Reset

1. Press the ALM RESET/ALM RECALL button. Notes: Alarm suspension applies to the whole system comprising the multiple system units, not to a selected unit alone.

ALM RESET

ALM RECALL
The alarm indicator goes off. Notes: Alarm reset operations (including auto reset) apply to the whole system comprising the multiple system units, not to a selected unit alone. Alarm reset mode differs depending on the system unit connected to the WV-CU360 when an alarm is reset. Confirm that the SHIFT button is released.

s Alarm Recall

The following function is available only in cases where system units with the alarm recall function are connected. 1. Select the desired system unit and monitor. 2. Press ALM RESET/ALM RECALL button after pressing the SHIFT button. The ALM RECALL indicator lights up. An alarm recall log appears on the monitor.

s Alarm Suspend

The following function is available only in cases where system units with the alarm suspend function are connected. 1. Press ALM SUSPEND button. The ALM SUSPEND indicator lights up.
3. To cancel the alarm recall function, press the ALM RESET/ALM RECALL button after pressing the SHIFT button again.

ALL RESET

The System Controller WV-CU360 can be reset to the default settings as follows: 1. Keep the DC plug of the supplied AC adapter connected, while pressing numeric buttons 4, 5 and 6 simultaneously. 2. When all indicators light up, resetting is completed. Note: Keep the DC plug of the supplied AC adapter connected to the DC 9V Input Jack until all resetting completes.
SYSTEM UNIT AND CAMERA SETUP
You can setup the system unit and the camera with the setup menu by this controller. For further information, refer to the Operating Instructions for system units and the individual combination cameras.

4. Press the HOME/PRESET/PROGRAM PRESET button while holding down the PROGRAM/CAM SETUP/CAM FUNCTION button. The actual camera position of the preset number programmed in procedure 4 is learned as preset. PROGRAM

CAM SETUP PROGRAM PRESET

SPECIFICATIONS
Power Source: Power Consumption: Data Output/Input Port: Switching Functions (WJ-MP204): Switching Functions [WJ-FS309 (WJ-FS316)]: Controller Number Unit Address Selection: Monitor Number Selection: Camera Number Selection: Camera Main Control: Lens Functions: 9 V DC, 400 mA (Use the supplied AC adapter only.) 10 W 6-conductor modular jack (RS-485, Full Duplex) Camera selection Monitor Selection/Switching of Live and Playback/Changing of the number of the Multiscreen Picture/Still/Electronic Zoom/Sequence 1-8 (Rotary Switch) 1-99 1-99 1-199 Camera Setup Camera Function Iris: Open/Close/Preset (only with DC control lens) Focus: Near/Far/Auto Focus Zoom: Wide/Tele Defroster: On/Off Wiper: On/Off Auxiliary 1: On/Off Auxiliary 2: On/Off Manual Pan: Right/Left Manual Tilt: Up/Down Auto Pan, Auto Sort, Auto Sequence, Random Pan, Preset Position, Home Position, Camera Patrol Camera selection Alarm (Display/Suspend/Recall/Reset) Setup 10C-+50C (14F-122F) Less than 90% 300 (W) x 74 (H) x 177 (D) mm [11-13/16 (W) x 2-15/16 (H) x 6 15/16 (D)] 1.3 kg (2.9 lbs.)

Housing:

Pan/Tilt:

System Operation:

Ambient Operating Temperature: Ambient Operating Humidity: Dimensions: Weight: Dimensions and weight are approximate. Specifications are subject to change without notice.

STANDARD ACCESSORIES

AC Adapter...1 pc 6-conductor Modular Cable Assembly..1 pc
Panasonic Security and Digital Imaging Systems Company A Division of Matsushita Electric Corporation of America
Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838 Midwest: 1707 North Randall Road, Elgin, IL 60123 (847) 468-5211 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7840

Panasonic Canada Inc.

5770 Ambler Drive, Mississauga, Ontario, L4W 2T3 Canada (905)624-5010
Panasonic Sales Company Division of Matsushita Electricof Puerto Rico Inc.
Ave. 65 de Infanteria. Km. 9.5 San Gabriel Industrial Park, Carolina, Puerto Rico 00985 (809)750-4300
NM1099-1129 Matsushita Communication Industrial Co., Ltd. 1999

YWV8QA5301BN

Printed in Japan N 19

 

Tags

ZEN-SP Powershot G7 C2210 32 KW 2200T Focal Dome G 1230 2442FX 644 B XMC2000 Brabus ICD-UX81F DCT2000 Urc-3415 Netdefend Systems VP-DC575WB 15200 SA-XR15 EK5162 42PF9952 12M DLE2516W DD505 SRU7040-10 6 4 531WH D350 4 L200B W2253V-PF CDM-7874 78-8846 SP-808 WD-16NEW QV-R61 KRC-794 Movie Cube 20VL63 KX-TG5100 PSR-36 RX-FT600 MX2500 01 Capri 8280 CMT-HX3 CD20T ICF-RN933 Acer P223 Elna 845 FA-150 HR2295-A Dell D600 SF-755P DC3410 SCH-8500 Travelmate 6252 Lavamat 620 Acco T40 WD-1021WF Blackberry 7510 York YS Super Duke 5630Z TX-28A1 D-EJ611 42VKX-AEX Review MDR-XB700 GK 1635 C905C WV-RC700A DXZ466MP 285 HV KRF-V7020 10 E Stylistic 2300 RFG297aabp XAA GA-8siml Marshall MB30 DVD-P355 TS-H552B Flextight 949 Kx-tg6074 350 VA ECM-HQP1 SGH-D908 K10ledv System GA-M68m-s2P DPS-V77 MPX 100 DSP-AZ2 WF6450S7W All-IN-ONE TX610FW MS8188E WM12-96 W1542S-PF NN-V453 Navigator DCR-DVD505 Bassfx Ho-2007

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101