Pentax Total Station R-300X
About Pentax Total Station R-300XHere you can find all about Pentax Total Station R-300X like manual and other informations. For example: review.
Pentax Total Station R-300X manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Pentax Total Station R-300X please write about it to help other people. [ Report abuse or wrong photo | Share your Pentax Total Station R-300X photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Pentax Total Station R-300X Digital Camera, size: 2.9 MB |
Pentax Total Station R-300X
User reviews and opinions
| rossisen |
7:26am on Friday, September 24th, 2010 ![]() |
| "I was given this drive as a gift for Christmas, and I can tell you right now its a life saver. "For my $ this is a good deal. Very rugged & saw on-line how it can be dropped from a ceiling & still work." Rugged. | |
| brianmosher |
3:59am on Monday, September 20th, 2010 ![]() |
| Overall a nice product. Two formats I regularly use on my computer and like to see on the screenplay are MKV and RMVB. I did my research around and until now iomega has this media player that competes with WD player. | |
| Blippo |
10:07am on Thursday, August 12th, 2010 ![]() |
| Great for marking disks. Easy To Read Print,Glides Smoothly,Good Colors,Ink Applies Evenly,Ink Dries Quickly,Long Lasting Ink Works fine Easy To Install | |
| mgsmith57 |
7:53pm on Tuesday, August 3rd, 2010 ![]() |
| The bold colors really make your labels stick out and the variety allows for visibility and easier organizing. Easy To Read Print,Good Colors. It is going quiet well. I am a kind of user who let me laptop run almost 20 hours a day. Easy To Install,Highly Compatible,Quiet,Reliable | |
| rlopes |
9:13pm on Wednesday, July 28th, 2010 ![]() |
| The product was advertised with the 8 pack of disks, but there was only 1 disk. I have found Zip/Rev disks to be the most reliable hard disk backup system yet developed. Tapes are slow and unreliable. | |
| issachary2k |
2:37am on Thursday, July 8th, 2010 ![]() |
| I am mostly on move for business. I carry lots of data every time and this drive is my constant partner. I love red color. I take this stylish ruby red rugged for all my travels. It is compact and quick. I cannot use the encryption feature to transfer my classified files on the corporate intranet network. | |
| spichanator |
11:41am on Monday, March 22nd, 2010 ![]() |
| Fast, Quiet; integrated USB and FireWire 400 hub, RUGGED, BE I DID NOT LIKE THE INCLUDED BACKUP SOFTWARE AT ALL. (USE "SU VERY RELIABLE ALSO ONLY PAID $95.00 AT WWW.NETS-INC.NET NONE | |
| jjsharshaw |
10:30pm on Sunday, March 14th, 2010 ![]() |
| The zip format is very convenient. I have been using them for years. I used to mail the 100mb disks overseas in just an envelope without a problem. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

Total Surveying Solutions
Electronic Quick Reference Guide Total Station
R-322NX R-323NX R-325NX R-335NX R-315NX
R-322EX R-323EX R-325EX R-335EX R-315EX R-326EX
The reflectorless function is applied to R-322NX, R-323NX, R-325NX, R-326EX, R-335NX, R-315NX
Basic Procedures for R-300X Series
PENTAX Industrial Instruments Co., Ltd.
2-5-2 Higashi-Oizumi / Nerima-ku, Tokyo 178-0063, Japan Tel. +/ Fax +E-mail: international@piic.pentax.co.jp Website: www.pentax.co.jp/piic/survey www.pentaxR300X.com
Electronic Total Station
Quick Reference Guide Basic Procedures for R-300X series
R-322NX, R-323NX, R-325NX, R-335NX, R-315NX, R-322EX, R-323EX, R-325EX, R-335EX, R-315EX, R-326EX
The description concerning the reflectorless function in this guide is applied to R-322NX, R-323NX, R-325NX, R-326EX, R-335NX, R-315NX.
CONTENTS
General Instruction Manuals Precautions regarding safety Warning Usage Precautions 1 Basic Operation 1.1 Removing the Battery 1.2 Attaching the Battery 1.3 Turning the Power On and Off 1.4 Centering and Leveling 1.5 Target Sighting (Focusing) 1.5.1 Auto-Focus 1.5.2 Power Focus 1.5.3 Manual Focus 1.5.4 Continuous AF mode 1.6 Angle Measurement 1.6.1 Horizontal Angle 1.6.2 Vertical Angle 1.7. Distance Measurement 1.7.1 Select your target 1.7.2 Distance Measurement 1.7.3 Changing Target constants 1.7.4 Input Temperature and Atmospheric pressure 1.7.5 Laser pointer 1.7.6Adjusting Laser Plummet brightness 1.7.7 Adjusting LCD contrast 1.7.8 Adjusting Illumination brightness 2 Changing Instrument Settings 3 Basic Field Checking Procedures 3.1 Electronic Vial 3.2 Laser Plummet 3.3 Laser Pointer 3.4 Warning and Error Messages 3.5 Atmospheric Correction 4 Specifications Notice to the user of this product
Instruction Manuals Quick Reference Guide is intended to provide a quick reference in the field. For ease of use in the field, the following Quick Reference Guide booklets are provided in the carrying case. 1. Basic procedure 2. PowerTopoLite for R-300X series, Operating procedure The complete instruction manuals are contained on the CD that is attached to each R-300X. This guide uses the symbol xN as an expression of repeating times of key operation. For example. ESC x2 means that [ESC] key is pressed two times. The symbol +expresses that multiple keys are pressed simultaneously. PRECAUTIONS REGARDING SAFETY Before using this product, be sure that you have thoroughly read and understood the instruction manual that is included in the attached CD-ROM to ensure proper operation.
WARNING
Solar Observation Never view the sun directly using the telescope as this may result in loss of sight. Laser Safety R-300NX is a class-IIIa (3R) Laser product. Avoid direct eye exposure. R-300X without NX is a class-II (2) Laser product. Do not stare into laser beam. Electro-Magnetic Compatibility (EMC) This instrument complies with the protection requirement for residential and commercial areas. If this instrument is used close to industrial areas or transmitters, the equipment can be influenced by electromagnetic fields.
Risk of Explosion Do not use this product in a location where there is coal dust, or near flammable material as there is a risk of explosion.
USAGE PRECAUTIONS
Target Constant Confirm the Target Constant of the instrument before measurement. Reflectorless and Reflecting sheet The reflectorless measurement range may vary depending on the target and surrounding brightness. In case the reflectorless measurement results in low accuracy, perform the distance measurement by Reflector sheet or Prism. (R-322NX, R-323NX, R-325NX, R-335NX, R-315NX,) Battery & Charger Use the battery charger that is suitable to the battery you are using. If water should happen to splash on the instrument or the battery, wipe it off immediately and allow it to dry in a dry location. Auto focus The Auto focus may not function under every condition depending on brightness,contrast,and the shape and size of the target.In such a case, use the Power Focus buttons or the manual focus ring. Atmospheric correction During surveys for which the survey precision or atmospheric measurement method is defined, measure the atmospheric temperature and pressure separately and enter those values rather than using the Automatic Atmospheric Correction function.
1. Basic Operation
1.1 Removing the Battery (1) Rotate the knob above the battery pack counter-clockwise. (2) Lift up the battery pack and remove it from the instrument. 1.2 Attaching the Battery (1) Place the channel on the bottom of the battery pack, onto the protrusion of the instrument and push the battery pack down into place. (2) Turn the knob clockwise. 1.3 Turning the Power On and Off To set power on : To shut down : Electronic vial screen
NOTE: The power is automatically turned off after 10 minutes of inactivity (Factory default setting). 1.4 Centering and Leveling (Laser plummet and Electronic vial) To activate electronic vial : To activate laser plummet :
PLUM.ADJ
(for the first time after power on)
or: To deactivate :
NOTE: The laser plummet and the electronic vial are always activated at the same time.When the power is switched on, however, only electronic vial is activated (Factory default setting). To change the power-on activation of laser plummet, refer to 2.3 Instrument setting itemsF.
1.5 Target Sighting (Focusing) 1.5.1 Auto-Focus Aim using the telescope collimator, and press NOTE: Place the target near the reticle center.The AF sensor is located around the horizontal line of the reticle. 1.5.2 Power focus If the AF failed or if you need to adjust the focus, use the Power focus knob. To focus on a closer object : Rotate Power Focus knob clockwise To focus on a farther object : Rotate Power Focus knob counterclockwise NOTE: Focus speed can be controlled by the rotation angle of the knob: Low speed: when rotated by approx. 5 degrees Middle speed: when rotated fully by approx. 10 degrees High speed: after one second of time has passed in the middle speed position 1.5.3 Manual focus Rotate the focus ring manually: 1.5.4 Continuous AF mode To activate the continuous AF: for 2 seconds
NOTE: Track the target by keeping the target close to the center of the reticle as much as possible. To quit: or rotate the Power focus knob :
NOTE: In case the focus does not change for one minute, the continuous AF mode will also terminate automatically.
1.6 Angle Measurement 1.6.1 Horizontal Angle Set the screen MODE A :
0 SET F3 HOLD F3
MODE A screen
Control keys for measuring horizontal angle: To set the angle to 0 To hold the angle To release HOLD To input an angle : : : :
0 SET F3 MODE F5 HOLD F3 MODE F5 ANG SET F2 F4 SELECT F5 ENT
HOLD F3
input value by using: To read clockwise angle : 1.6.2 Vertical angle To display vertical angle :
F1 MODE F5
F2 ANG SET F2
SELECT F5
DISP F4
To change permanently the combination of values displayed in MODE A: ESC x2 SELECT x3 SELECT +
F2 F5 F4 F5
Select by
ENT F4 MODE F5
To read the slope %
ANG SET F2
1.7 Distance Measurement Set the screen MODE A:
1.7.1 Select your target Select target type (measurement mode): (Reflecting sheet)
TARGET F2
(Prism)
(Reflectorless)
NOTE: The selected target is maintained until next time you change. 1.7.2 Distance measurement For a single shot measurement:
MEAS F1
When Long Range Mode is displayed
NOTE: Long Range Modeis displayed only when measuring with higher laser power (in reflectorless measurement with the instrument setting REF.LESS RANGEset as LONGand Warning Messageset as ON).
For tracking measurement
NOTE: The number of shots can be defined.The default is one time The measuring modes activated by the above operations. can be also changed.
NOTE: Quick mode is the function to shorten the initial measurement time using prism and reflector sheet.To set the mode, use direct command number [0][0][7][5][2][2].When the meas key is pressed during quick mode, <-- --> is displayed on the screen. 1.7.3 Changing Target constants The default constants are: Reflecting sheet : 0mm Prism : -30mm Reflector-less : always 0mm Before changing the constants, set Target Constant in the Initial Setting to INPUT mode: ESC SELECT x2 x2 ENT x3 +
F4 F5 F4
To change Prism constant: input value by using : ,
MODE F5
CORR F4
SELECT F5 ENT
CORR F4 F4
To change Sheet constant: input value by using:
1.7.4 Input Temperature and Atmospheric pressure The default atmospheric correction mode is Automatic. Before manual input, change the default mode to ATM INPUT : +
ESC F4
SELECT F5 CORR F4 F4 F4
To Input temperature
x2 , 0
input value by using:
To Input atmospheric pressure:
MODE F5 CORR F4 F4
x3 , 0
input value by using: 1.7.5 Laser pointer To activate Laser pointer : To quit Laser pointer :
LD POINT F2 LD POINT F2
NOTE: The laser pointer is kept activated until it is deactivated by the above procedure. 1.7.6 Adjusting Laser Plummet brightness
ENT F2
1.7.7 Adjusting LCD contrast +
LCD F4 F1
1.7.8 Adjusting Illumination brightness +
ILLU F5
for LCD
RECTICLE F3
(for Reticle)
2. Changing Instrument settings
You can change the instrument settings by HELP menu or by inputting 007 code. 2.1 Help menu While the screen is in MODE A or MODE B, +
Select a desired item by
F4 ENT
Change the setting
NOTE: Some items have sub-menus where the selecting procedure by using F1 - F4 is again repeated. 2.code While the screen is in MODE A or MODE B,
Input 007 code by using 0
NOTE: Some items have sub-menus where the selecting procedure by using F1 - F4 is again repeated. 2.3 Instrument setting items See chart on page 15
007 code 401 PRISM CONST SHEET CONST SHOT CONT SHOT INPUT
HELP menu list TARGET CONST
ATM CORR MEAS. MIN DISP SHOT COUNT
PRIM.MEAS KEY SEC.MEAS KEY AUTO MEAS. PRIORITY DISP
CRV/REF CORR MIN UNIT ANG. V. ANG. STYLE DIST.BUZ QUAD BUZ AUTO OFF EDM OFF ILLU.OFF MEAS.SIGNAL PRIORITY SELECT
LD PLUM. TILT DISP. TILT DISP.UNIT RANGE MESSAGE SETUP TEMP.UNIT PRESS UNIT BAUD RATE DATA LENGTH PARITY BITS STOP BITS SIGNAL CONTROL XON/XOFF THROUGH COMMAND
517 520
COMP AXIS LD PLUM.&E.VIAL
REF.LESS RANGE
522 701
QUICK MEAS ATM UNIT
DIST.UNIT ANG.UNIT SET UP COM.
Default -30mm 0mm AUTO COARSE 1 time 01 times 0.14 FINE Z.0 ON OFF 10 MIN 3 MIN 3 MIN MARK MEAS SHOT TRACK CONT NIL HA/HD/VD 3 Axis (2/3model) or 2 Axis OFF (when Power On) OFF COARSE NORMAL ON (when Range is LONG) EACH TIME (w/ Power ON) OFF Centigrade hPa m DEG NIL 1 ON ON NIL
Other options 0mm, INPUT INPUT ATM INPUT, ppm INPUT, NIL FINE 3 times, 5 times, INPUT (input) 0.2, NIL COARSE H.0, COMPASS OFF ON 20 MIN, 30 MIN, NIL 5 MIN, 10 MIN, NIL 5 MIN, 10 MIN, NIL VALUE MEAS CONT, TRACK SHOT, TRACK CONT TRACK SHOT, MEAS CONT, MEAS SHOT MEAS., TRACK HA/VA/SD, HA/VA/HD/SD/VD 2 Axis (2/3 model), 1Axis, , NIL ON (automatically ON) ON FINE LONG OFF PERMANENT ON Fahrenheit mmHg, inchHg ft, ft+inch DEC, GRD, MIL 2400, 4800, EVEN, ODD 2 OFF OFF a, b, c, d, e,f
3. Basic Field Checking Procedures
Checks and Adjustments should be performed before and during measurement. 3.1 Electronic Vial To display vials:
(from measurement screen)
Check if the bubble stays at the center of each vial, when rotating the instrument by 180. To adjust the vials: + instruction on the screen operate according to the
NOTE: Press these two keys for 1 second longer, then release key first.
3.2 Laser Plummet To activate the laser plummet: (for the first time after Power on) or
Check if the laser spot on the ground stays at the same position when rotating the instrument around the vertical axis. To adjust the laser plummet: Contact your local dealer 3.3 Laser Pointer To activate the laser pointer: or (from measurement screen)
Check if the projected laser spot points at the same position that is aimed by the center of the cross-hair line of the telescope. To adjust the laser pointer: Consult your local dealer.
3.4 Warning and Error Messages Warning Message
Out of tilt range
Meaning
Displayed when the instrument is tilted beyond the vertical compensation range (3) in case 1 axis or 2 axis automatic compensation is selected. This message may be temporarily displayed if the instrument is turned too fast.
What to do
Re-level the instrument. Repair is needed if the message is displayed when it is properly leveled.
Excess data
The input data exceeds the allowable Press the [ESC] key and enter the correct data. range. This message is displayed if a long Select the correct target mode. distance which is a far beyond measurable distance of R-300X series is measured with a wrong target mode. Please select a correct target then measure. If a wrong target is selected, a correct distance cannot be measured. Select a longer point, The measurement distance is less than 1.5m in Reflector sheet mode. or use a tape measure. The measurement distance is less than 1.5m in Prism mode. Under too strong sun light. Unstable light value owing to shimmer or obstacles. Reflector sheet, Target and Prism do not face the instrument. Reflector sheet,Target and Prism are not correctly sighted. Measurement range is over in Reflectorless mode. Sufficient signal does not return by sighting sharp edge etc. at Reflectorless mode. The Date Clock is powered by the built-in lithium battery. The lithium battery needs to be replaced in five years. Change the object that has much better reflectivity, or use a reflecting sheet, or wait until the sun activity has weakened.
Mismatched Target
Target is too close.
Unsuitable Condition
Li-batt.voltage is low.
Have the lithium battery replaced by the dealer from whom the instrument was purchased.
Error Message Meaning
ERROR!! EDM ERROR Distance measurement system problem 04 -05, 34-39, 50-53 ERROR!! ETH ERROR 70-76 Angle measurement system problem
Turn the power off, and then turn on again. Repair is needed when the message appears consistently.
Memory problem ERROR!! MEMORY ERROR 19
ERROR PS DATA of EDM Problem of the internal EDM parameters ERROR P DATA of EDM
ERROR ETH DATA
Problem of the internal ETH parameters
3.5 Atmospheric Correction The speed at which light travels through the air varies depending on the temperature and atmospheric pressure. The R-300X series is designed to measure distances at the speed of light in order to measure accurately, atmospheric correction needs to be used. The instrument is designed to correct for weather conditions automatically if the temperature and pressure are input. Correction is then carried out based on the following formula. Calculation formula: K= (276.26713 - 78.565271 P ) x10-6 273.14941 + t K: Atmospheric Correction Constant P: Atmospheric pressure (hPa) t: Temperature(C) Distance after Atmospheric Correction D = Ds (1+K) Ds: Measured distance when no Atmospheric Correction is used.
4. Specifications
Reflectorless items are applicable to NX models only.
R-322NX R-323NX R-325NX R-335NX R-315NX R-322EX R-323EX R-325EX R-335EX R-315EX R-326EX Telescope Magnification 30 x Resolving power 3 Field of view 2.6% (1 30) Minimum focus 1.0m Focus Auto-focus / Power Focus / Manual Manual Distance measurement Visible Laser: Class II (2) Laser Class Visible Laser: Class II (2) / Class IIIa (3R) - Long range mode in Reflectorless (NX models only) Measurement range (Good condition) Reflectorless 1.5m - Normal range mode: 90m / Long range mode 200m (NXmodels only) Reflector sheet 1.5m-600m (800m) Mini prism 1.5m-1100m (1600m) 1P 1.5m-3400m (4500m) 1.5m-3000m (4000m) 1.5m-2000m (2800m) 3P 200m-4500m (5600m) 200m-4000m (5000m) 200m-2800m (3500m) Accuracy Prism (2+2ppm x D)mm (3+2ppm x D)mm Reflector Sheet Reflectorless (5+2ppm x D)mm (5+3ppm x D)mm At Auto-Atm.Correction Prism, Ref.sheet: (2 +10ppm x D)mm / (3+10ppm x D)mm Reflectorless: (5 + 10ppm x D)mm (NXmodels only) Minimum count Fine mode (0.1mm) Normal mode (1mm) Track mode (1cm) Measuring time Repeat meas. Normal: Prism, Ref.sheet 2.0sec.(1mm) Normal: Prism, Ref.sheet 1.2sec. (1mm) Track: Prism, Ref.sheet 0.4sec.(1cm) *Quick mode Initial meas. Normal: Reflectorless 2.3sec.(1mm) Normal: Prism, Ref.sheet 2.5sec. (1mm) (NXmodels only) *Quick mode Angle measurement Measuring method Absolute rotary encoder Detection 2 sides Minimum count 1 (2cc) / 5 (10cc) selectable Accuracy(ISO 17123-3) Compensator Triple axis Dual axis Tangent screw 2 speed 1 speed Sensitivity of vials Plate level (electronic) 30/1div. Circular level 8/2mm Plummet Visible Laser, 0.8mm (instrument height 1.5m) Base Detachable Shifting Fixed Detachable Water resistant IP56 Ambient temperature -20C ~ +50C / -4F ~122F (Working range) Tripod thread 5/8 x 11 35mm x 2 5/8 x 11 Dimensions/Weight Instrument 177(W) x 343(H) x 177(L)mm Weight (incl. Battery) 5.7kg 5.5kg 5.7kg Carrying case 268(W) x 442(H) x 465(L)mm/3.9kg Battery pack BP02 Power source Ni-MH (Rechargeable)(4300mAh) , DC6V Operation time Continuous Approx. 5 hrs (ETH+EDM),12 hrs (ETH) with Approx. 2.2 hrs of charging time Weight Approx. 380g
R-322NX R-323NX R-322EX R-323EX Charger BC03 and AC Adapter AC01 Input voltage (AC01) AC 100~240V (AC01) Output voltage (BC03) DC7.5V (BC03) Weight 280g Internal Memory Coordinates data 20000 points Date Clock NX MODEL Yes EX MODEL Yes
R-325NX R-325EX
R-335NX R-335EX
R-315NX R-315EX
R-326 EX
16000 points Yes No
12000 points No
NOTE: * The measurement range may vary by measurement conditions. * Normal conditions: 20km visibility with slight shimmer. * Good conditions: 40km visibility, overcast, no heat, no shimmer and moderate wind. * Reflector sheet: PENTAX genuine Reflector sheet (5cm x 5cm). * Quick mode, which is effective only under Normal mode (1mm) setting, functions with Prism and Reflector Sheet. It is incorporated in all X series models and effective up to 500m. * When Quick Mode is on, the EDM accuracy using Prism and Reflector Sheet is (3+2ppm x D)mm. When Automatic Correction is activated in Quick Mode, the EDM accuracy is (3+10ppm x D)mm * EDM Measuring time varies according to distance to be measured and conditions of the environment. * Reflectorless: - The measurement range and accuracy of Reflectorless are based on the condition that laser beam is emitted perpendicular to the white side of the Kodak Gray Card. There is a possibility that the range may vary when the target does not satisfy the conditions above at survey work. - The measurement range may be influenced by the shape of the target and its environment. - The measurement range at TRACK mode is over 5m. * The operating time becomes shorter under the low temperature, due to the temperature dependence of the battery performance. * The points that can be recorded in one job file are maximum 2,000 measuring points (XYZ). The user can make up to 50 job files. Job history can be managed thanks to date clock recorded in each job file.
NOTICE TO THE USER OF THIS PRODUCT
To assure compliance with the Safety standard 21 CFR, Chapter 1. Subchapter J. The U.S. bureau of Radiological Health requires the following information to be provided to user.: It can be dangerous to look into the beam with optical equipment such as binoculars and telescopes.
1. Specifications of Laser Radiation A) The EDM module of the R-300X produces a visible light beam, which is emitted from the telescope objective lens and the center hole of the instrument base plate.The R-300X is designed and built to have a laser diode radiating at 620-690nm. B) Radiant power The R-300X is designed and built to radiate a maximum average radiant power of 4.75mW (0.95mW for the model without NX) from the telescope,and 0.95mW from the center hole of the base plate.The user may be subject to this radiation as a beam while operation until such time that the instrument is turned off.
2. The following labels are affixed to and must remain attached to this laser product. A) The following Certification label is located near the Plate level: This laser product is complied with the provisions of 21 CFR 1040. 10 and 1040.11. For a Class II laser product. Or for R-300 NX models: This laser product is complied with the provisions of 21 CFR 1040. 10 and 1040.11. For a Class IIIa laser product. B) Caution label is located near the exit aperture: AVOID EXPOSURE. Laser radiation is emitted from this aperture.
C) Warning logotype is located on the surface of the telescope: CAUTION LASER RADIATION DO NOT STARE INTO BEAM Or for R-300 NX models: DANGER LASER RADIATION AVOID DIRECT EYE EXPOSURE D) Warning label is Located near the exit aperture.
3. Caution to maintain the safety in compliance with the standard A) To maintain the safety standard, refrain from any operation, maintenance, or adjustment other than described in this instruction manual. B) Operation, maintenance or adjustment other than those specified in this instruction manual may result in hazardous radiation exposure. C) Maintenance and repair not covered in this manual must be done by an authorized Pentax dealer. D) The Laser beam emission by the Distance measurement can be MEAS terminated by pressing F1 key. E) Pressing keys can terminate the laser beam emission F2 by the laser pointer. F) The Laser beam emission by the Laser plummet can be terminated by pressing key.
LD POINT
AVOID EXPOSURE Laser radiation is emitted from this aperture
Aperture label
Warning label Laser beam is transmitted from this aperture
R325EX R325NX R335EX R335NX R315EX R315NX R322EX R322NX R323EX R323NX R326EX
Identification label
AVOID EXPOSURE
Laser radiation is emitted from this aperture
Laser beam is transmitted from this aperture
Warning logotype
For R-300NX model
LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
DANGER
For R-300EX model
CAUTION
R GE DAN
DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT
SE OIDEXPO ER LAS
ION AT E DIECT EY DUCT DIR R RA SUREPRO
SS CLA
For North America Certification
2-5-2 Higashi Ozumi Nerima-ku. Tokyo 178-8555 Japan This Laser product is complied with the provisions of 21 CFR 1040-10 and 1040-11 For a class IIIa product ASSEMBLED BY PENTAX VN Co. LTD Sai Dong B Industrial zone. Gia Lam. Hanoi Vietnam
2-5-2 Higashi Ozumi Nerima-ku. Tokyo 178-8555 Japan This Laser product is complied with the provisions of 21 CFR 1040-10 and 1040-11 For a class II product ASSEMBLED BY PENTAX VN Co. LTD Sai Dong B Industrial zone. Gia Lam. Hanoi Vietnam
LED is turned on at the time of emission
LASER RADIATION - DO NOT STARE INTO BEAM
620-690nm/0.95mW max.
CLASS II LASER PRODUCT
Laserclass II, conform FDA 21 CFR Ch. 1 1040
LASER RADIATION - DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENT INTO SUNLIGHT
CLASS IIIa LASER PRODUCT
Laserclass IIIa, conform FDA 21 CFR Ch. 1 1040
620-690 nm/4.95mW max.
PENTAX Industrial Instruments Co., Ltd. 2-5-2 Higashi-Oizumi Nerima-ku, Tokyo 178-0063, Japan Tel. +Fax +E-mail: international@piic.pentax.co.jp Website: www.pentax.co.jp/piic/survey
Japan Surveying Instruments Manufacturers Association
Member symbol of the Japan Surveying Instruments Manufacturers Association representing the high quality surveying products.
022005 First edition TS01401
Printed in Belgium

R-300X Series Specifications
Reflectorless items are applicable to "NX" models only R-322NX R-323NX R-325NX R-335NX R-315NX R-322EX R-323EX R-325EX R-335EX R-315EX Telescope Image Erect Magnification 30 X Resolving power 3 sec. Optical aperture 45mm (EDM aperture: 45mm) Field of view 130 (2.6%) Minimum focus 1.0m Recticle illumination Intensity settings: 10 steps Auto focus / Power focus Yes (and Manual) Method Phase differential Power Main battery Pointer Visible laser EDM Laser class Visible Laser: Class II (2) / Class IIIa (3R) - long range mode in Reflectorless ("NX" models only) Measurement range (Good condition) Reflectorless 1.5m - Normal range mode: 90m / Long range mode 270m ("NX" models only) Reflector sheet 1.5m - 600m (800m) Mini prism 1.5m - 1100m (1600m) 1P 1.5m - 3400m (4500m) 1.5m - 3000m (4000m) 3P 200m - 4500m (5600m) 200m - 4000m (5000m) Accuracy Prism (2+2ppm x D)mm Reflector sheet Reflectorless 1.5 to 200m: (5 + 2ppm x D)mm 1.5 to 200m: (5 + 3ppm x D)mm Over 200 to 270m: (7 + 10ppm x D)mm Over 200 to 270m: (7 + 10ppm x D)mm At Auto-Atm. Correction Prism, Ref.sheet: (2 + 10ppm x D)mm / Reflectorless: (5 + 10ppm x D)mm ("NX" models only) Minimum count Fine mode (0.1mm) Normal mode (1mm) Track mode (1cm) Measuring time Repeat meas. Normal: Prism, Ref.sheet 2.0sec. (1mm) Normal: Prism, Ref.sheet 1.2sec. (1mm) Track: Prism, Ref.sheet 0.4sec. (1cm) *Quick mode Initial meas. Normal: Reflectorless 2.3sec. (1mm) Normal: Prism, Ref.sheet 2.5sec. (1mm) ("NX" models only) *Quick mode Target selection Non Prism 0 offset Reflector sheet 0 offset / +99 ~ -99 offset Prism 0 offset / -30 offset / +99 ~ -99 offset Angle Measurement Type Absolute Rotary Encoder Method Horizontal: 2 sides / Vertical: 2 sides Accuracy (ISO17123-3) 5 Minimum count 1 Compensator Triple Axis Dual Axis Display / keyboard Display Type Graphic LCD / 20 alphanumeric 8 lines / 240 x 96 pixels Quantity (2nd optional) Keys 22 each (12 numeric / 5 function / 5 special) Display back light Intensity settings: 10 steps Date Clock NX MODEL Yes Yes EX MODEL Yes No Physical Tangent screws 2 speed 1 speed Vials Plate (electronic) 30 / 1 div. Circular 8 / 2mm Plummet Visible laser Accuracy 0.8mm (instrument height 1.5m) Intensity 10 steps Base Tribrach Shifting Fixed Working temperature -20 C ~ +50 C / -4 F ~ +122 F Dust and Water protection IP56 Tripod thread 5/8 x 11 Instrument dimensions 177 (W) x 343 (H) x 177 (L) mm Inst. weight (with battery) 5.7 kg / 12.6 lbs 5.5 kg / 12.1 lbs Case dimensions 268 (W) x 442 (H) x 465 (H)mm Case weight 3.8 kg / 8 lbs Battery Varies by country (standard camcorder battery, Ni-MH rechargeable DC6V) Charger Input voltage AC 100~240V (AC01) Output voltage DC7.5 (BC03) Internal Memory Coordinates data 18.600 points 16.000 points
Note: * The measurement range may vary by measurement conditions. - Normal conditions: 20km visibility with slight shimmer. - Good conditions: 40km visibility, overcast, no heat, no shimmer and moderate wind. * Reflector sheet: PENTAX genuine Reflector sheet (5cm x 5cm). * Quick mode, which is effective only under Normal mode (1mm) setting, functions with Prism and Reflector Sheet. It is incorporated in all X series models and effective up to 500m. * When Quick Mode is on, the EDM accuracy using Prism and Reflector Sheet is (3 + 2ppm x D)mm.When Automatic Correction is activated in Quick Mode, the EDM accuracy is (3 + 10ppmxD)mm. * EDM Measuring time varies according to distance to be measured and conditions of the environment.
R-326EX
Reflectorless Measurement Mode
by Pentax
Innovative Dual Mode EDM Measuring system
No more obstacles on the construction site with Pentax R-300X. Simply select the desired laser mode by striking one of the five function keys and you can measure objects up to 270 meters away without a prism.
Total Surveying Solutions
No (Manual) Visible Laser: Class II (2) 1.5m - 2000m (2800m) 200m - 2800m (3500m) (3 + 2ppm x D)mm (3 + 10ppm x D)mm
R-322NX R-323NX R-325NX R-335NX R-315NX
R-322EX R-323EX R-325EX R-335EX R-315EX R-326EX
Centralize data
The R-300X Total Stations incorporate a clock allowing time and date data to be recorded in the jobfile, making it possible for the user to effectively manage job history. Four classes of angular accuracy 2 (0.6mgon); 3 (1mgon), 5 (1.5mgon) and 6 (1.9mgon) > 11 models > two configurations > minimum count of 1 > FIT EVERY APPLICATION
* Designs and specifications are subject to change without notice. - Printed in Belgium - PENTAX 2006 - AS591320 - SURVEY/01/01/06
On-board software PowerTopoLite
R-300X comes equipped with full-featured PowerTopoLite software that helps you handle your most difficult survey jobs. This powerful software package features an easy-to-use operator interface that guides you through all measuring jobs. PowerTopoLites architecture provides open access to a number of powerfull integrated functions to solve any advanced surveying application.
Reliability made by Pentax:
Waterprotection IP56
The R-300X complies with the most stringent international industry standards. It is designed and engineered to ensure accuracy and reliability under the harshest work conditions, at the same time protecting your investment. (The degree of protection against dust and water of the R-300X complies with the International Protection standard IP56 defined following the standard IEC 60529).
Tribrach
5.7 kg / 12.6 lbs
12.000 points
Reliable Data Exchange with DL-01
Information is exchanged via a standard RS232 cable. DL-01 software supports all upload and download between PENTAX surveying instruments and PCs. DL-01 allows direct exchange of data from any software. It operates under Windows 95, 98, 2000 & NT and Windows XP. Data can be converted into the following formats: Pythagoras files, DXF, JS-Info, TDS, SDR,TAB separated ASCII, DC-1Z, 3 User Definable Formats and various other accepted formats.
Reflectorless: - The measurement range and accuracy of Reflectorless are determined by the white side of the Kodak Gray Card. - The measurement range may be influenced by the shape of the target and its environment. - It takes time, longer than usual, to measure the distance exceeding 200m or to measure the distance to the object that is hard to measure. - The maximim distance that can be shown on the display is 322m in the non-prism measurement mode. - The measurement range, accuracy of distance measurement and time required to measure may be influenced by the shape, size of surface area and reflection rate of the target and its environment.
PENTAX Industrial Instruments Co., Ltd. World Headquarters 2-5-2 Higashi-Oizumi Nerima-ku, Tokyo 178-0063, Japan Tel.: +Fax: + e-mail: international@piic.pentax.co.jp www.pentax.co.jp/piic/survey
European Headquarters PENTAX Technologies Europe-Surveying Div. Weiveldlaan 3-5 B-1930 Zaventem, Belgium Tel.: +Fax: +e-mail: info_survey@pentaxeurope.com
CAUTION
LASER RADIATION - DO NOT STARE INTO BEAM
620-690 nm/0.95mW max.
DANGER
LASER RADIATION - DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENT INTO SUNLIGHT
CLASS II LASER PRODUCT
Laserclass II, conform FDA 21 CFR Ch. 1 1040
CLASS IIIa LASER PRODUCT
Laserclass IIIa, conform FDA 21 CFR Ch. 1 1040
620-690 nm/4.95mW max.
Visit the R-300X series at: www.pentaxsurveying.com
Japan Surveying Instruments Manufacturers Association
Your Official Pentax Dealer
Member symbol of the Japan Surveying Instruments Manufacturers Association representing the high quality surveying products.
Pentax R-300X series
Stretching the limits.
R-300X
Optimal configuration, optimal productivity
R-300X Key features
On-board memory: 18.600 points Measurement time to prism/reflector sheet: 0.4 sec in Tracking Mode and 1.2 sec in Quick Mode setting EDM accuracy: (2+2ppm) on all models, except R-326EX (3+2ppm) Date clock on all non prism models Reflectorless measuring up to 270m Single prism measuring up to 4.500m (14,764 ft), with (2+2ppm) accuracy
Four classes of angular accuracy 2 (0.6mgon); 3 (1mgon), 5 (1.5mgon) and 6 (1.9mgon) Applications: Surveying Construction Industrial applications Free Station Stake Out Reference Line / Arc Area Calculation Tie Distance Height transfers Inaccessible Points Prismless Auto Focus EDM Reflective tapes may also be used as targets Auto Focus [World First Triple Focusing System] World First Dual Prismless Mode EDM [90 / 270m] Telescope with 30x magnification Visible Laser pointer Automatic Atmospheric Correction Indicator LED for Laser beam Ni-MH Battery With the compact standard camcorder Ni-MH battery (rechargeable DC6V), the R-300X user can go anywhere to measure for up to a whole working day (6 - 12 hours) without having to depend on a power source. Large graphic display Large 20 character x 8 line graphic display for simple operation. Electronic vial easy-to-operate through function keys. Incorporated date clock for more efficient job management. Alphanumeric Keyboard (10 easy-to-operate keys) Compact and Lightweight (12.1lbs / 5.5kg - 12.6 lbs / 5.7kg battery incl.) Dual Axis Compensator guarantees perfect horizontal and vertical alignment and performs fine levelling. Triple Axis Compensator for R-322 and R-323 models (NX and EX).
The noted Pentax
features
Autofocus (World First Triple Focusing System) 30x magnification of telescope Large, high resolution screen guarantees a clear display Intuitive program structure
Precision at the speed of light
The R-300X-series from Pentax incorporates two precise user selectable lasers, made for high inspection throughput and improved measurement efficiency in any possible job. This makes the Pentax R-300X Total Station a versatile measuring system that brings you and your customers important cost savings. These features, together with a measurement time of 0.4 sec in tracking mode and 1.2 sec in quick mode, contribute to an excellent productivity of Pentax R-300X total stations.
Standard configuration
Battery pack Battery charger Plumb Bob A set of tools Rain cover Carrying case Manual
optional accessories
SB-12 SC-6
Simple operation
All functions are initiated from just five keys. A function that keeps the operation intuitive and logical. Easy-to-use alphanumeric keys (10 keys) allow you to enter quickly specific characters, numbers and other information.
Large memory
The on-board memory of 18.600 measuring points (XYZ) allows you to handle efficiently any measurement and inspection tasks.
Max. 2.000 measuring points (XYZ) can be recorded in one job file. The user can make up to 20 job files.
Highest standard in Waterprotection IP56 (following the IEC 60529 standard). Laser plummet for easy and quick set-up Makes it easy to center over a set up point and step-by-step adjustable intensity of the plummet laser point to critical lighting conditions.
* 2nd display standard on R-322(N)X and R-322X, the other models have 1 display. The 2nd display (TA 06) is optional.
MPU-5A/5B
MPU-20
(Mini Prism Set)
Tags
Officejet 4200 DCR-DVD404E RX-MDX85 Dobsonians XL2400 Dualmaster V1 00 JFS516 HTS9800W Senseo Edition MC275 A63270GT 30LB120S4 SX700 Lavalogic1600 8700 LSW MP190 EL-546V SGH-F250L NS-125F Router 775VM8 Mediaboard PRO ED-205 WS-2010 NAD 711 Contax TVS3 FS-SD7 LN40C530 42WM03LW MY226X QG-HS850 LN32C450e1 500 VA BCD-165D KX-TG2422W Rdm 127 Presario 2800 FBD103 Z1020C NV-GS40 LE-37R81B B5941-5-M Navigon 7110 G43twins-fullhd Webcam Alpha Sound ICF-CD543RM Acer P223 Digimaxa502 47WLT66 VT45K LE37B530 VPC750BT Router 5100 CI Nitro Kart DTR4610 STR-DB940 Sview04 Charger KDL-22L5000 Suunto M1 GT-I6220 KV-28EW20U MM-S8 Flash RX700 Dimension 4300 Edifier R251 865PE7MF TH-37PX8ESA JBL 5234 Messenger B1445V Custom Navigon 2310 LS 600 SGH-P900 SRA-50 DVP-NS710H KX-TG7322FR W350I Review LE27S73BD DCT758 GC-L197NFS DCD5505W Ixus 95IS SSC130B HL-5250DN OT-255 EWD2203 SHR-M1 ER350 KDC-5080R DVD-7711N Linux Microtower PC
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding