Sailor HF Ssb Re2100
|
|
Bookmark Sailor HF Ssb Re2100 |
About Sailor HF Ssb Re2100Here you can find all about Sailor HF Ssb Re2100 like manual and other informations. For example: review.
Sailor HF Ssb Re2100 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Sailor HF Ssb Re2100 please write about it to help other people. [ Report abuse or wrong photo | Share your Sailor HF Ssb Re2100 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Sailor HF Ssb Re2100, size: 1.0 MB |
Sailor HF Ssb Re2100
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

OPERATOR MANUAL RADIOTELEPHONY
HF SSB RE2100 SAILOR COMPACT 2000 PROGRAMME
FOR YOUR INFORMATION
All information and illustrations in this manual are based on the information available when this manual was printed. We make reservations concerning errors in this manual, and all specifications are subject to change without further notice. S.P. Radio A/S has the copyright, all rights are reserved. Copyright 1993-95. Doc. No.: B2100GB Issue: D/9510
RE2100/C2140/R2120/T
CONTENTS 1 GENERAL INFORMATION
1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.kHz Distress Urgency signal Safety Signal Silence Periods Operating Simplex Communication Duplex Communication 1-1 1-1 1-1 1-1 1-1 1-1 1-1 1-1
CONTROLS SYSTEM DESCRIPTION
3.1 3.2 3.3 3.4 3.5 3.6 General Simplex Radiotelephone Standard System Duplex Radiotelephone Telegraphy Remote Control DSC/Telex 3-1 3-1 3-1 3-1 3-1 3-1
READ-OUT
4.1 4.2 Radiotelephony Radiotelephony and Telegraphy 4-1 4-1
OPERATION
5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.10 5.11 5.12 5.13 5.14 5.15 5.16 Operating Hints Initial Settings Select a Frequency Clear the TX Display Select Mode Turn OFF/ON the AGC Turn OFF/ON the Squelch Reduce/Increase the Tx Power Level DIM the Display Tune the Receive Frequency Clarify the Received Signal Return to Receiver Frequency Mode from Clarifier Mode Select Built -in Dummy Load for Tx Output Power Test Test the Alarm Signal Generator Start a New Transmitter Tune-up Cycle Interrupt a Transmitter Tune-up Cycle 5-1 5-1 5-1 5-1 5-1 5-2 5-2 5-3 5-3 5-3 5-3 5-3 5-4 5-4 5-4 5-4
CHANNEL MODE OPERATION
6.1 6.2 6.3 6.4 6.5 6.6 6.7 6.8 6.9 Operation in CH Mode Select an ITU Channel Select a Quick Select Channel Number Store a New Frequency Pair in Quick Select Channel 0-99 Change the Content of a Quick Select Channel Delete the Content of a Quick Select Channel Check which Quick Select Channel Numbers are already Used Convert a Selected Channel to a Corresponding Frequency Pair Convert a Frequency Pair to a Corresponding Quick Select Channel Number 6-1 6-1 6-1 6-1 6-1 6-2 6-2 6-2 6-2
SCANNING OPERATION
7.1 7.2 7.3 7.4 7.5 7.6 Use the Scan Programme Build-up a Scan Programme Start a Scan Programme Stop a Scan Programme Check the Content of a Scan Programme Delete a Channel from a Scan Programme 7-1 7-1 7-1 7-1 7-1 7-2
DISTRESS CALL PROCEDURE
8.1 8.2 8.3 8.4 Distress Call on 2182 kHz Stop the Alarm Signal Transmit the Alarm Signal on a Frequency other than 2182 kHz Ships Identity Information 8-1 8-1 8-1 8-2
SWEEP OPERATION
9.1 9.2 9.3 9.4 General Programming of the Sweep Programme Start/Stop of the Sweep Programme Delete a Frequency from the Sweep Programme 9-1 9-1 9-3 9-4
10 DUPLEX OPERATION
10.1 10.2 10.3 10.4 General Select Duplex Mode by means of Frequencies Select Duplex Mode by means of Channel Number Return to Simplex Mode 10-1 10-1 10-2 10-2
11 TELEGRAPHY OPERATION
11.1 11.2 11.3 11.4 11.5 11.6 11.7 General Connection Unit H2185 Select Telegraphy Mode Start Transmission of Telegraphy Stop Transmission of Telegraphy Enter BFO Control Mode Return from BFO Control Mode 11-1 11-1 11-1 11-1 11-2 11-2 11-2
12 MANUAL TUNE-UP PROCEDURE 250W SYSTEM 13 MANUAL TUNE-UP PROCEDURE 600W/1200W SYSTEM 14 OPEN/GROUNDED AERIAL
14.1 Ground the Aerial 14.2 Open the Aerial 14.3 Return from the Open or Grounded Aerial 14-1 14-1 14-1
15 ERROR MESSAGES 250W SYSTEM
15.1 Error Messages from the Receiver/Exciter RE2100 15.2 Error Messages from the Transmitter T2130 15.3 Example 15-1 15-1 15-1
16 ERROR MESSAGES 600W/1200W SYSTEM
16.1 Error Messages from the Receiver/Exciter RE2100 16.2 Error Messages from the Transmitter T2131/T2135 16.3 Example 16-1 16-1 16-1
17 OPERATION REMOTE CONTROL UNIT
17.1 17.2 17.3 17.4 17.5 17.6 General Description Stand-By Mode Active Mode Intercom Mode Radiotelephony Call Distress Call 17-1 17-1 17-1 17-1 17-1 17-2
18 QUICK SELECT/FREQUENCY TABLE 19 QUICK SELECT CHART
1 GENERAL INFORMATION
1.kHz 1.6 Operating
The international distress and call frequency 2182 kHz may be used for distress communication, urgency and safety transmissions, as well as ordinary calls between stations participating in the maritime mobile service. The distress call must have absolute priority over all other transmissions.
The operating panel is provided with a very high quality push-button keyboard panel offering an attractive solid feel. Furthermore, keyed operations are instantly confirmed by means of the display read-out. To ensure safe operation under all conditions, the keyboard is fitted with night-time illumination.
Distress
RX kHz TX kHz
The radiotelephone distress procedure must consist of: - The alarm signal (whenever possible) followed by: - the distress signal MAYDAY (three times). - The words this is. - The name of the ship in distress (three times). - MAYDAY (once). - The name of the ship. - The position expressed in longitude and latitude or by bearing to a familiar geographic point. - The nature of the distress and the kind of assistance needed. - Any other information which might facilitate the rescue, e.g. how many men on board.
DIM DUMMY LOAD
Simplex Communication
Urgency signal
The urgency signal consists of three repetitions of the group of words PAN PAN. The message must be addressed to a particular station or to all stations. The signal indicates that the calling station has a very urgent message to transmit concerning the safety of a ship or the safety of a person. The urgency signal must have priority over all other communications except distress.
The HF SSB Radiotelephone is normally operated in the simplex/semi-duplex mode. This means that communication only takes place in one direction at a time. To operate the system you have to press the handset switch and deliver your message, which must be ended with the word over. The switch is now released, allowing the other person to reply.
Safety Signal
The safety signal consists of the word SECURITY. The signal indicates that the station is about to transmit a message containing an important navigational or important meteorological warning. The safety signal must be transmitted on 2182 kHz, and the message which follows the call should be transmitted on a working frequency.
Duplex Communication
Silence Periods
Stations normally watch keeping on 2182 kHz must endeavour to watch for three minutes twice each hour beginning at xx hour 00 and xx hour 30 UTC, the so called silence periods. During silence periods distress and urgency traffic are allowed only. However, safety signals may be transmitted during the last 10 seconds of a silence period.
If your HF SSB Radiotelephone is fitted with the Duplex Receiver R2120, you have the opportunity to communicate in full duplex mode. This means that communication can take place in both directions at the same time. To operate the system you just have to press the handset switch and then make your conversation.
RE2100/C2140/R2120/T - GENERAL INFORMATION
VOL O F F RF
SIGNAL AE CURRENT 0.2 3
RX kHz TX
TX POWER
DIM DUMMY LOAD MODE
CLARIF
POWER SQ
SEND ALARM
TEST ALARM
ADD DEL
VOL O F F
CONTROLS
Volume control and on/off switch for the mains.
Sets the decimal point for the frequency in kHz.
(Digits 0-99)
Adds the RX/TX frequency to the channel number. Deletes the RX/TX frequency from the channel.
Manual RF gain control.
Tunes the receive frequency down.
Resets the tune memory at the selected frequency and starts a new tune-up cycle.
Tunes the receive frequency up.
TUNE CLARIF
Switches between clarifier (10 Hz steps) and tune of receive frequency. Selects receive functions or converts a channel number to the corresponding frequency.
Selects channel functions.
Selects transmit functions or converts a channel number to the corresponding frequency.
Reduce/increase the transmitter output power. Selects the built-in dummy load in the aerial coupler, and the TX frequency 2206.4 kHz is automatically selected.
DUMMY LOAD
Transmits the distress signal when pressed simultaneously with TEST ALARM.
Selects the distress frequency 2182 kHz.
RE2100/C2140/R2120/T - READ-OUT
Operating Hints
When TX mode is selected, the full stop sign in the TX display flashes. After 10 secs, the full stop sign will stop flashing and the receiver/exciter will return to RX mode. Default settings are: AGC on, Squelch on, and Full TX-Power. When pressing the handset key, the tune lamp is alight, and when it extinguishes, the set is ready for operation.
Initial Settings
Turn VOL/OFF knob to approx. mid position and turn RF gain knob fully clockwise.
1. Press:
Select a Frequency
Receive frequency e.g. 4125.0 kHz. Read-out:
SIGNAL AE CURRENT
J3E SQ
2. Press:
Transmit frequency e.g. 4125.0 kHz. Read-out:
Press:
Clear the TX Display
Read-out:
SIGNAL AE CURRENT 0.RX kHz TX TX POWER
Select Mode
For frequencies below 1605 kHz, H3E mode is automatically selected. For frequencies above 1605 kHz, J3E upper sideband is automatically selected. J3E R3E H3E LSB/J3E = SSB with suppressed carrier and upper sideband = SSB with reduced carrier and upper sideband = AM with upper sideband = SSB with suppressed carrier and lower sideband Read-out:
R3E SQ
To change the mode press:
RE2100/C2140/R2120/T - OPERATION
H3E SQ
LSB J3E SQ
Turn OFF/ON the AGC
Turn OFF/ON the Squelch
SIGNAL AE CURRENT RX kHz TX TX POWER
Read-Out:
Reduce/Increase the Tx Power Level
STEP 1
STEP 2
STEP 3
STEP 4
1/2 STEP 4 STEP 3
1/4 STEP 2
1/8 STEP 1 STEP 0
and up again
It is only necessary to press the TX button when more than 3 secs have elapsed between each press of the AGC/ POWER button.
DIM the Display
Step 1: Dimmes the light in the display and keyboard light is on. Step 2: Switches off both the display light and the keyboard light. Step 3: Undimmed light in the display and the keyboard light is off. Step 0: Normal light in the display and the keyboard light is off. (Default setting)
5.10 Tune the Receive Frequency
FREQ FREQ
100 Hz steps in the J3E, R3E and LSB modes 1 kHz steps in the H3E mode.
5.11 Clarify the Received Signal
to select the clarifier mode.
to decrease the frequency in 10 Hz steps (max. 150 Hz) Press:
to increase the frequency in 10 Hz steps (max. 150 Hz)
5.12 Return to Receiver Frequency Mode from Clarifier Mode
5.13 Select Built -in Dummy Load for Tx Output Power Test
DUMMY LOAD J3E SQ
The display will now show TX frequency 2206.4 kHz and the DUMMY LOAD sign is on. Key the transmitter and wait until the TUNE sign is off, whisle into the microphone and check that the aerial current indicator reads at least 2 amps.
5.14 Test the Alarm Signal Generator
The alarm signal is heard in the earpiece.
5.15 Start a New Transmitter Tune-up Cycle
Resets the tune memory at the selected frequency, and starts a new tune-up cycle. Only necessary when the aerial has been changed, or when installing the radio. Press:
5.16 Interrupt a Transmitter Tune-up Cycle
Operation in CH Mode
All ITU channel numbers have been pre-programmed in the receiver/exciter. Furthermore it is possible to programme 100 user defined quick select channels.
Select an ITU Channel
e.g. channel 421.
Select a Quick Select Channel Number
e.g. channel 43. Read-out:
(observe, the set will go to the next programmed channel, if the selected channel is empty).
Store a New Frequency Pair in Quick Select Channel 0-99
e.g. in channel 20. Key-in the wanted RX/TX frequencies and mode, e.g. RX = 1635 kHz, TX = 2060 kHz, J3E. Then press:
Change the Content of a Quick Select Channel
e.g. channel 20. Key-in the wanted RX/TX frequencies and mode, e.g. RX = 1707 kHz, TX = 2132 kHz, J3E.
RE2100/C2140/R2120/T - CHANNEL MODE OPERATION
Then press:
Delete the Content of a Quick Select Channel
e.g. channel 20. Press:
(Observe, the set will go to the next programmed channel).
Check which Quick Select Channel Numbers are already Used
Select a channel number, then Press:
you will step through the channel register starting from the displayed channel number.
Convert a Selected Channel to a Corresponding Frequency Pair
Convert a Frequency Pair to a Corresponding Quick Select Channel Number
Note: If the frequency keyed-in is an ITU frequency, it is not possible to go from frequency to channel number.
Use the Scan Programme
There are 10 scan programmes (0-9) and each of them is able to contain 128 channel numbers (ITU and quick select channel numbers can be used).
Build-up a Scan Programme
e.g. programme 2, consisting of e.g. channel 4, channel 421, channel 1604. Press:
STOP STOP
J3E SQ AGC
ADD SQ
Start a Scan Programme
e.g. programme 1. Read-out:
Stop a Scan Programme
Check the Content of a Scan Programme
e.g. programme 2.
General
The system has 10 programmable sweep programmes (SC numbers 10 to 19). Each programme has the following parameters, which can be changed by means of a programming menu. Trigger Source Code 0) Squelch trigger with full RF sensitivity (manual RF-gain is disabled). 1) Squelch trigger with adjustable RF sensitivity (manual RF-gain is adjustable). Dwell Time Dwell time in steps of 100 ms from 0.3 secs to 9.9 secs. Listen period when any activity has been detected on a frequency. Intervals from 1 sec to 60 secs, increasing 1 sec each interval. Delta frequency between two listen frequencies. Intervals from 100 Hz to 9900 Hz, increasing 100 Hz each interval. From 100 kHz to 29999.9 kHz, increasing 100 Hz each interval. From 100 kHz to 29999.9 kHz, increasing 100 Hz each interval.
Hold Time
Step Frequency
Start Frequency
Stop Frequency
Selected Invalid Frequencies When the sweep programme is running, a max. number of 12 frequencies can be deleted from the sweep frequency band.
Programming of the Sweep Programme
and then two digits to give the number of the sweep programme (10-19). Read-out: and to select the sweep programme number 12.
E.g. press
RE2100/C2140/R2120/T - SWEEP OPERATION
Press ADD to start the programming menu. The display will ask for the Trigger Source Code Co and show the value of the present code in the first line. The trigger source code is an indication of the RF level at which the receiver will stop the sweep function. Key in a value for the trigger source code (0 or 1) followed by
SQ ADD SQ
or press
to accept the present trigger source
value.
The sweep function uses squelch at full RX sensitivity which means that the manual RF-gain control is disabled. The sweep function uses squelch at reduced RX sensitivity determined by the manual RF gain control setting.
The dwell time dt is the time the sweep programme stops to listen on a frequency to detect whether any communication takes place.
Key in a dwell time (0.3 to 9.9 secs) followed by
to accept the present dwell time.
The Hold time Ht is the time the sweep programme stops to listen on a frequency if any activity has been detected.
Key in the new Hold time (1 to 60 secs) followed by
to accept the present hold time.
The Step Frequency SF is the delta frequency between the frequencies on which the sweep programme will listen. Key in a new step frequency (0.1 to 9.9 kHz) followed by
, or press
to accept the present step frequency.
The start frequency is the frequency at which the sweep programme will start every time the sweep programme is selected. If the start frequency is higher than the stop frequency, then the sweep programme runs backwards. Key in the new start frequency (begin Frequency) bF (100.0SQ SQ
29999.9 kHz) followed by present start frequency.
to accept the
When the sweep programme passes the stop frequency, the sweep programme will return to the start frequency. Key in the new stop frequency (End Frequency) EF (100.0SQ SQ
29999.9 kHz) followed by present stop frequency.
When the last ADD was pressed, the lower line in the display changed from Pr EF to SC-12. This means that the programming of sweep programme No. 12 is finished, and sweep programme No. 12 is now running from the start frequency, which is displayed in the upper line.
Start/Stop of the Sweep Programme
When the lower line in the display shows SC followed by two digits, then the sweep programmes start or stop running
when the
button is pressed.
If the upper line shows a frequency with the clarifier digit on, then the sweep programme is stopped manually, and it will start running from the frequency on which the sweep programme was stopped. When the sweep programme is stopped manually, the up/ down arrow keys can be used to adjust the receiver frequency. When a new sweep programme has to be started, or the sweep programme has to be started from the start freSC
followed by the two digits for the quency, then press sweep programme number.
Delete a Frequency from the Sweep Programme
It is possible to delete a frequency from a running sweep programme. In case the sweep programme stops automatically at the same frequency every time it passes, and the user does not want to listen on that frequency, the user can delete the frequency from the sweep programme. When the programme stops automatically on a frequency,
MODE DEL and the frequency will be deleted from the then press sweep programme. Next time the programme passes that frequency it will jump over.
To restore a deleted frequency, press
followed by
In case the step frequency is lower than 1 kHz, the sweep programme jumps over a 2 kHz band with the deleted frequency as the centre frequency. The max. number of deleted frequencies is 12.
11.1 General
To obtain the facility of telegraphy, your HF SSB Radiotelephone System must be fitted with the Duplex/Telegraphy Receiver R2120T and the CW Unit H2185. The interconnection between these units and the standard equipment for simplex radiotelephony is shown in the block diagram. The selection of frequencies and mode is performed from the Keyboard of the Receiver/Exciter RE2100. The mode used for telegraphy is named CW, which stands for Continuous Waves.
11.2 CW Unit H2185
The CW Unit H2185 is used as interface between the Morse Key and the Radio System. The transmitted symbols (dots and dashes) are transformed into an audible tone by means of the Side Tone Oscillator inside H2185. The frequency of this tone is factory adjusted to 600 Hz, but it can easily be adjusted to another frequency by means of a potentiometer at the rear panel of H2185. The volume is controlled by means of the Volume Control at the front plate of H2185, which also includes on/off switches for external and internal loudspeakers. The CW Unit H2185 also includes a connector for a Headset, which contains both microphone and earpiece. The Headset is always listening-in when the telegraphy mode is selected, but it can also be used for both simplex and duplex radiotelephony. The activation of the microphone and thereby the transmitter is controlled by means of the foot switch PTT (Press To Talk).
TRANSMITTER
OPTIONAL Loudspeaker H2054 H2185 CW Unit
MORSE KEY PTT
28899B
11.3 Select Telegraphy Mode
MODE DEL Select the CW mode with the key. Key-in the wanted RX/TX-frequency. E.g. RX/TX = 4187 kHz.
The mode lamp CW will now light up.
11.4 Start Transmission of Telegraphy
When Telegraphy mode has been selected, activate the Morse Key for a short moment. When the Morse Key is released and the possible tune procedure is ended, the transmitter will be turned off. The Exciter will still be active and generate a carrier signal ready for Telegraphy transmission. Now, every time the Telegraphy Key is activated, the transmitter will be turned on for a period equal to the key activation time. This means that the Telegraphy System is ready for use and thereby ready for transmission of dots and dashes.
RE2100/C2140/R2120/T - TELEGRAPHY OPERATION
11.5 Stop Transmission of Telegraphy
To turn off the Exciter and thereby stop the transmission of telegraphy press:
11.6 Enter BFO Control Mode
The frequency of the BFO (Beat Frequency Oscillator) is factory adjusted to give an audio signal with a frequency of 1000 Hz, every time a dot or a dash is received. The frequency of the BFO can be adjusted from the keyboard at the Receiver/Exciter Unit RE2100 to give an audio signal from 300 Hz to 1,4 kHz. To change the frequency of the BFO, please follow the procedure described below. Select Telegraphy mode as described in section 11.3. To enter BFO control mode, press:
To increase or decrease the BFO frequency, press:
11.7 Return from BFO Control Mode
To return from BFO control mode, press:
12 MANUAL TUNE-UP PROCEDURE 250W SYSTEM
Turn the system off Remove the cover
on the Transmitter 250W. from the cover.
Remove the tuning tool
Transmitter 250W
Set tune switch
to position man.
Turn the system on
28071A-GB
S1 TUNE
Remove the plug
in the bottom of the aerial coupler to max. light in the tuning tool.
and tune the aerial coupler by means of the supplied tuning tool
When tuned to max. press Press ALARM and alarm signal.
SEND TEST ALARM
simultaneously to transmit the
When the alarm signal disappears from the earpiece (After 45 secs), then press the handset key and make your distress call. (MAYDAY - name of ship - position etc.) Release the handset key and listen for an answer.
Aerial coupler
26996A
28070A-GB
RE2100/C2140/R2120/T - MANUAL TUNE-UP PROCEDURE 250W SYSTEM
13 MANUAL TUNE-UP PROCEDURE 600W/1200W SYSTEM
Turn the system off Open the cover
on the transmitter. to position man.
AUTO MAN
Place the tuning indicator
(the fork) on the
TUNE SWITCH
aerial insulator on the top of the aerial coupler. 8 Remove the plug
in the bottom of the aerial coupler
31825-GB
to max. light in the tuning indicator.
When tuned to max. press
Press ALARM and alarm signal.
When the alarm signal disappears fron the earpiece (After 45 secs), then press the handset key and make your distress call. (MAYDAY - name of ship - position etc.) Release the handset key and listen for an answer.
Aerial Coupler
31826-GB
RE2100/C2140/R2120/T - MANUAL TUNE-UP PROCEDURE 600W/1200W SYSTEM
14 OPEN/GROUNDED AERIAL
Note! Aerial is grounded when the set is switched off.
14.1 Ground the Aerial
14.2 Open the Aerial
14.3 Return from the Open or Grounded Aerial
RE2100/C2140/R2120/T - OPEN/GROUNDED AERIAL
15.1 Error Messages from the Receiver/ Exciter RE2100
Error codes: 00. Internal power supply is low. Check the power connections to the Receiver/ Exciter RE2100, or check the internal power regulators. 76. 11. Illegal transmitting frequency. The Tx frequency, at which a tune sequence has been tried, is not legal. Illegal transmitting mode. The selected mode (type of modulation) is not legal for transmitting. Keying sequence has not been finished by the
High Standing Wave Ratio (SWR) when transmitting. Check the Aerial and see technical manual for the Transmitter T2130. If the Aerial is OK, press:
Battery voltage low. Check the condition of the batteries and the power cables. See technical manual for the Transmitter T2130. Temperature sensor error. See technical manual for T2130. Internal high Standing Wave Ratio (SWR). See technical manual for T2130.
78. 15.
15.3 Example
If the communication link between the Receiver/Exciter Unit RE2100 and the Transmitter T2130 has been interrupted, The read out shows:
SIGNAL AE CURRENT 0.RX kHz TX
The communication link between the Receiver/ Exciter RE2100 and the Transmitter T2130 has been interrupted. Check the SP-BUS coax cable (blue marks) between these units. The communication link between the Receiver/ Exciter RE2100 and the Control Unit C2140 or the Telex/DSC Receiver Modem RM2150/ RM2151, has been stopped. See technical manual for Receiver/Exciter RE2100. The communication link between the Receiver/ Exciter RE2100 and the Duplex/Telegraphy Receiver R2120/T has been stopped. Check the SP-BUS coax cable (blue marks) between these units.
15.2 Error Messages from the Transmitter T2130
Error codes: 70. Motor circuit error in Aerial Coupler AT2110. See technical manual for the Transmitter T2130. Forward voltage low. See technical manual for the Transmitter T2130. Forward voltage high. See technical manual for the Transmitter T2130. High Standing Wave Ratio (SWR) when tuning the Aerial Coupler AT2110. Check the Aerial and see technical manual for the Transmitter T2130. Transmitter temperature too high. Let the Transmitter T2130 cool down. Ensure free air flow at both the top and the bottom of the Transmitter.
16.3 Example
If the communication link between the Receiver/Exciter Unit RE2100 and the Transmitter T2131/T2135 has been interrupted. The read out shows:
RE2100/C2140/R2120/T - ERROR MESSAGES 600/1200W SYSTEM
17.1 General Description
The remote control unit may be in one of the following modes, Stand-by Mode, Active Mode or Intercom Mode.
17.4.1
Operation
17.2 Stand-By Mode
In stand-by mode all the handsets at the remote control units and receiver/exciter are placed in the hooks. In this mode all units are able to control the receiver/ exciter. Loudspeakers are on. Earpiece and microphone are off.
In order to select intercom mode, press the button and then the number of the wanted intercom unit. When the audible tone is heard, lift the handset and make your telephone conversation. Note that the loudspeaker of the called unit is switched on, until the handset is lifted from the hook. This means that a person at the called unit is able to receive the message, without lifting the handset from the hook. To end an intercom you just place the handsets in the hooks.
17.4.2 17.2.1 Operation
All receiver functions are operational, except for the RF gain control.
Priority
17.2.2
All connected units have different priorities. The priority is defined in the software and must be programmed after installation (see the instruction book for the Control Unit C2140). Intercom has low priority and it is always possible to interrupt an intercom from a unit with a higher priority. In order to do this, lift the handset
All connected remote control units are able to control the Receiver/Exciter RE2100.
from the hook and press the
button.
17.3 Active Mode
In active mode, one unit has the handset removed from the hook. All other units, which are not active, shows HF-OCC (HF occupied) in the display.
17.4.3
Intercom Call
e.g. from Control Unit No. 1 to Control Unit No. 2.
17.3.1
your read-out IC-2 Control Unit 2 reads-out IC-1 other control units read-out IC-OCC
All operation and all functions are the same as described for the Receiver/Exciter RE2100.
Radiotelephony Call
Lift the handset from the hook (now you have command of the Receiver/Exciter RE2100). Select the receive and transmit frequencies or a channel as described for the Receiver/Exciter RE2100. Make your call as described for the Receiver/ Exciter RE2100. Your read-out: The selected frequencies or the channel. All other units read-out: HF-OCC and all other units are muted. Persons at a unit with higher priority than the active unit are able to take over the control by lifting the handset from the hook and then press
17.3.2
All connected units have different priorities. The priority is defined in the software and must be programmed after installation (see the instruction book for the control Unit C2140. Units with higher priority than the active one are always able to take over the control of the Receiver/Exciter RE2100. To do this, you just lift the handset from the hook and
press the button: ENT. You will now be able to operate the system as normal and all other units will show HF-OCC (HF-occupied) in the display.
17.4 Intercom Mode
In intercom mode a telephone conversation can take place between two units. All other units, which are not participating in the intercom, shows IC-OCC (intercom occupied) in the display.
RE2100/C2140/R2120/T - OPERATION REMOTE CONTROL UNIT
17.6 Distress Call
The button has always 1st priority. All control units have 1st priority. You may start a call from one unit and then continue the call from another unit.
17.6.1
Make Distress Call
Follow the same procedure as described in chapter 8.
18 QUICK SELECT/FREQUENCY TABLE
(max. 1024 frequencies of which 100 can be stored as quick select frequencies)
STATION
TRANSMITTER Frq. No.
RECEIVER Frq. No.
RE2100/C2140/R2120/T - QUICK SELECT/FREQUENCY TABLE
Notes:
19 QUICK SELECT CHART
Distress and Call Frequency
Send ALARM
Stop ALARM
RX Frequency Selection
TX Frequency Selection
Quick Select Channels
ITU Channel Selection
Operation: Press handset key, wait until the tune light extinguishes, and then make your call. Release the handset key, and wait for an answer.
RE2100/C2140/R2120/T - QUICK SELECT CHART
SAILOR
63 5$',2 $6 3RUVYHM 32 %R[ '. $DOERUJ 69 'HQPDUN 3KRQH )D[ 7HOH[ 635$' '. (PDLO VDLORU#VDLORUGN :HE ZZZVDLORUGN
Tags
Lide 80 MX-J55R Scph-30004R P2470LHD MHC-RG590S CD4450S Laserjet 8150 OT-203C Enhanced HD12538J HP-3700 STX999L Autopilot SD210U Elite IM-DR80 Infiniti J30 Amex 601 UA-4FX Jetdirect 615N Kenwood 600 Ftxr42EV1B9 2300DN Sunfire 1999 Digimax A6 Travelmate-4050 PMD201 Monitor Kodak M381 Hifax 17 ROC 3407 IC-775 SL-PG480A Predator 2 CD 235 UX-MD9000R DN-V210 QW14760 Roadmate 2000 Wonder PRO HK 825 SCB-100 PSP2 0 WD-12397TD KDC-W4544U Creative 2170 Distance DX4000 En-el3e Mouse TX-NR905 W380A MAX PL KDL-40W5000 DCR-SR220E TY-WK4p1RW Wiport Submachine GUN IC-251AE KDL-32EX401 SHE43C-shu42 Metaboli Dc-nikkor WFE1266A SCH-V910 Sidekick II Xpression SS-MF400H HS082HB Phonefax 2320 Huawei E960 Rings GTA 475 Panasonic P50 EW643F AP-45 SRS-Z510 Software 583CX LD-2040WH Digitrack VGN-S5m-S DA4352 Tomtom XXL 480DF DSC-S980 B VLT2081 Precision 8D IHP-120 T-405X 20PF5120-28B 19DX IV BH-205 Models NAS-D55HD DS8411P MIO C210 Review Degroupee Iseki MC4 2125 Cdma
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101
