Samsung SH12ZWH
About Samsung SH12ZWHHere you can find all about Samsung SH12ZWH like manual and other informations. For example: review.
Samsung SH12ZWH manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Samsung SH12ZWH please write about it to help other people. [ Report abuse or wrong photo | Share your Samsung SH12ZWH photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Samsung SH-12ZWH Dvd Recorder, size: 1.3 MB |
Related manuals Samsung SH12zwhd-XSA Samsung SH-12zwhd/ser Samsung SH-12zwhx Samsung SH12ZWH-SEK Samsung SH-12zwh/ser |
Samsung SH12ZWH
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
DB98_15924A(3)_co
4/6/04 3:16 PM
Page 3
ROOM AIR CONDITIONER
INDOOR UNIT
SH09AWH SH09ZWH AQ09WHWE KFR-25G/SWA SH12AWH SH12ZWH AQ12WHWE KFR-35G/SWA
OUTDOOR UNIT
SH09AWHX SH09ZWHX UQ09WHWE KFR-25W/SWA SH12AWHX SH12ZWHX UQ12WHWE KFR-35W/SWA
SERVICE
AIR CONDITIONER
Manual
CONTENTS 1. Product Specifications 2. Disassembly and Reassembly 3. Refrigerating Cycle Diagram 4. Set Up the Model Option 5. Troubleshooting 6. Exploded Views and Parts List 7. Block Diagram 8. Wiring Diagram 9. Schematic Diagram
DB98_15924A(3)_1
4/6/04 2:59 PM
Page 1
1. Product Specifications
1-1 Table
Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R410A) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8./ 36 / / 36 / 34 2.81 3.22 1-220 / 240-900 4.5 4.5 96.5 95.5 21.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.2 6.35 x 7.5 9.52 x 7.x 550 Rotary Induction Motor(PSC) 900 DAPHNE FV68S(PVE) Cross-flow steel 15 2ROW 14STEP MRA99134-9201 INDOOR UNIT : DB27C WB19C INDOOR UNIT : DB32C WB23C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE Cross-flow steel 15 2ROW 14STEP 520 1,020 MRA99908-9201 OUTDOOR UNIT : DB35C WB24C OUTDOOR UNIT : DB43C WB26C CAPILLARY TUBE 720 x 548 x 265 28.4 x 21.6 x 10.4 31.x 285 x 189 32.5 x 11.2 x 7.44 8.4 6.35 x 7.5 9.52 x 7.x 550 Rotary Induction Motor(PSC) 1,075 DAPHNE FV68S(PVE) Propeller steel 50 2ROW 24STEP SH09AWH Indoor unit 2.75 2.90 1./ / 51 8.3 9./ 39 / / 39 / 37 2.82 3.23 1-220 / 240-50 1,240 1,300 5.7 5.7 98.3 98.0 30.0 250V-10A 720 x 548 x 265 28.4 x 21.6 x 10.4 33.8 Outdoor unit Indoor unit 3.5 4.2 1./ / 53 SH12AWH Outdoor unit
Wall-mounted
Samsung Electronics
Page 2
Table(cont.)
Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R22) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8./ 36 / / 36 / 34 2.70 3.22 1-220 / 240-50 1,4.5 4.0 98.2 99.1 21.0 250V-10A 825 x 285 x 189 32.5 x 11.2 x 7.44 8.2 6.35 x 5.0 9.52 x 5.x 550 Rotary Induction Motor(PSC) 1,005 SUNISO-4GSD Cross-flow steel 15 2ROW 14STEP RAC12110-9622 INDOOR UNIT : DB27C WB19C INDOOR UNIT : DB32C WB23C Propeller steel 50 1ROW 24STEP CAPILLARY TUBE steel 15 2ROW 14STEP RAC12074-9622 OUTDOOR UNIT : DB35C WB24C OUTDOOR UNIT : DB43C WB26C CAPILLARY TUBE Cross-flow 720 x 548 x 265 28.4 x 21.6 x 10.4 31.x 285 x 189 32.5 x 11.2 x 7.44 8.4 6.35 x 5.0 12.70 x 5.x 550 Rotary Induction Motor(PSC) 1,206 SUNISO-4GSD Propeller steel 50 2ROW 24STEP Indoor unit 2.70 2.90 1./ / 51 8.3 9./ 39 / / 39 / 37 2.99 3.48 1-220 / 240-50 1,170 1,150 5.2 5.2 96.9 96.2 30.0 250V-10A 720 x 548 x 265 28.4 x 21.6 x 10.4 33.8 SH09ZWH Outdoor unit Indoor unit 3.5 4.0 1./ / 53 SH12ZWH Outdoor unit
Model Item Type Cooling Heating Dehumidifying Air Volume Performance Noise Energy Efficiency Ratio Power Power Consumption Operating Current Power Power Factor Starting Current Length Power Cord Number of Core Wire Capacity Outer Dimension Weight(Net) Refrigerant Pipe Drain Hose Size Compressor Oil Type Type Blower Heat Exchanger Refrigerant Control Unit Freezer Oil Capacity Refrigerant to Change(R22) Protection Device(OLP) Cooling Test Condition Maximum Operation Condition cc g Motor Type Rated Output W Type Motor Type Rated Output Liquid GAS Width x Height x Depth A mm inch kg mm x L(m) mm x L(m) D x L(mm) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating kW kW |/h m3/min dB W/W V-Hz W A % A m 7.3 8.0
5) Loosen 2 fixing screws of Front Grille.
Page 6
Disassembly and Reassembly
Procedure 6) Unlock 2 hooks to fix Panel Front and Tray Drain.
Remark
7) Unlock 3 hooks to fix Panel Front and Back-Body.
Control-In (Main PCB)
1) Take all the connector of PCB upper side out. (Inclusion Power Cord) 2) Detach the outdoor unit connection wire from the Terminal Block. 3) Loosen 4 fixing screws of Ass'y Control-In.
Tray Drain
1) Pull Tray Drain out from the Back Body.
Page 7
Parts Heat Exchanger 1) 2) 3) 4)
Procedure Loosen 2 fixing earth screws of right side. Detach the Connection Pipe. Detach the Holder Pipe at the rear side. Loosen the 3 fixing screws of right and left side. 5) Lifting the Heat Exchanger up a little to push the up side for separation from the indoor unit.
Fan Motor & Cross Fan
1) Loosen the fixing screw and detach the Motor Holder. 2) Detach the Fan Motor from the Fan. 3) Detach the Fan From the left Holder Bearing.
Page 8
2-2 Outdoor Unit
No 1 Parts Common Work Procedure 1) Loosen each 3 fixing screws on both right and left Cabinet-Side edge and a fixing screw on the Cabinet-Front lower to detach the Cabinet-Front. Remark
2) Loosen 2 fixing screws of the Ass'y-Control.
3) Loosen 6 fixing screws of the Cabinet-Side RH.
4) Loosen 2 fixing screws of the Cabinet-Side LF.
Page 9
Parts Fan & Motor
Procedure 1) Detach the Nut Flange.(Turn counterclockwise because the screw is right-handed) 2) Detach the Fan. 3) Loosen 4 fixing screws to detach the Motor.
Heat Exchanger
1) Loosen 2 fixing screws on both sides. 2) Disassemble the pipe in both inlet and outlet with welding torch. 3) Detach the Heat Exchanger.
Compressor
1) Loosen the Terminal Cover nut to open the Terminal Cover. 2) Disassemble the cloth sound felt. 3) Disassemble the pipe in both inlet and outlet of the Compressor with welding torch. 4) Disassemble the pipe in both inlet and outlet of the Condenser with welding torch. 5) Loosen the 3 bolts at the bottom. 6) Detach the Compressor.
Page 10
Setting Option SEG2. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
3 1,4 2,5
Change it into the set display of Option SEG3 and SEG4 with the button.
Setting Option SEG3. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Setting Option SEG4. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
4/6/04 3:00 PM
Page 15
Set Up the Model Option
Change it into the set display of Option SEG5 and SEG6 with the button.
Setting Option SEG5. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Setting Option SEG6. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
6,9 7,10 8,11
Change it into the set display of Option SEG7 and SEG8 with the button.
Setting Option SEG7. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Setting Option SEG8. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Change it into the set display of Option SEG9 and SEG10
with the
button.
Setting Option SEG9. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Setting Option SEG10. Push the button to set the display panel to. Every time you push the button, the display panel reads. repeatedly.
Page 16
Step 3 : Upon completion of the selection, check you made right selections. Whenever you press the button, the set Option will be displayed.
Step 4 : Pressing the ON/OFF button ( ) When pressing the operation ON/OFF key with the direction of remote controller for unit, the sound "Ding" is heard and the OPERATION LED lamp is flickering at the same time, then the input of option is completed. (If the "ding" sound isn't heard, try again pressing the ON/OFF button.)
Step 5 : Unit operation test-run First, Remove the battery from the remote controller. Second, Re-insert the battery into the remote controller. Third, Press ON/OFF ( ) key with the direction of remote controller for set.
Error Mode 1st 2nd If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model.
Page 17
4-2 Table of the option Code
Model SEG1 SH12AWH SH12ZWH AQ12WHWE KFR-35G / SWA SEG2 SEG3 SEG4 Option Code SEG5 SEG6 SEG7 SEG8 SEG9 SEG10
SH09AWH
SH09ZWH AQ09WHWE KFR-25G / SWA F b
Page 18
5. Troubleshooting
Check the basic items first to judge if the problem was caused by breakdown or misuse. If none of the basic items are related to the problem, please scrutinize the machine according to the 'Breakdown Diagnosis by Symptoms' method.
5-1 Basic Breakdown Diagnosis Items
1. The input voltage should be rating voltage 10% range. The airconditioner may not operate properly if the voltage is out of this range. Is the link cable linking the indoor unit and the outdoor unit linked properly? The indoor unit and the outdoor unit shall be linked by 5 cables. Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables. Otherwise the airconditioner may not operate properly. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the malfunction of the airconditioner.
No 1 Operation of air conditioner The OPERATION indication LED(GREEN) blinks when a power plug of the indoor unit is plugged in for the first time. In a COOL operation mode, the compressor does not operate at a room temperature higher than the setting temperature that the INDOOR FAN should operate. In a HEAT operation mode, the compressor does not operate at a room temperature lower than the setting temperature that indoor fan should operate. Fan speed setting is not allowed in DRY( ) mode. Explanation It indicates power is on. The LED stops blinking if the operation ON/OFF button on the remote control unit is pushed. In happens after a delay of 3 minutes when the compressor is reoperated. The same phenomenon occurs when a power is on. As a phenomenon that the compressor is reoperated after a delay of 3 minutes, the indoor fan is adjusted automatically with reference to a temperature of the air blew. The speed of the indoor fan is set to LL in DRY mode. Fan speed is selected automatically in AUTO mode. ) Compressor operation is controlled automatically in DRY mode depending on the room temperature and humidity. When the unit is turned off while de-ice is activated, the compressor continues operation for up to 9 minutes (maximum) until the deice is completed. Timer is being activated and the unit is in ready mode. The unit operates normally if the timer operation is cancelled. The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protect the compressor from overheated air in a HEAT mode. The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heater operation The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozen depending on the inside/outside air temperature.
Compressor stops operation intermittently in DRY( mode.
Compressor of the outdoor unit is operating although it is turned off in a HEAT mode.
Timer LED(GREEN) of the indoor unit lights up and the air conditioner does not operate. The compressor and indoor fan stop intermittently in HEAT mode.
Indoor fan and outdoor fan stop operation intermittently in a HEAT mode.
The compressor stops intermittently in a COOL mode or DRY mode, and fan speed of the indoor unit decreases.
Page 19
5-2 Trouble check in the initial status
5-2-1 Diagnosis and marking of the part in trouble.
Please check the air conditioner operation status and write the check result in the chart in the room.
LAMP Description OPERATION TIMER TURBO
Indoor unit room temperature sensor error (open or short) Indoor unit heat exchanger temperature sensor error (open or short) Indoor fan motor mal function EEPROM error Option error (option wasn't set up or option data error)
: Lamp off : Lamp flickering
5-2-2 Operation with abnormal motion
No 1 Abnormal condition No response from the remote control operation signal. Inspection Plug out and plug in 5 seconds later. Able to operate the remote control. Unable to operate the remote control. Initial Diagnosis OK Press the button in the indoor unit. If it operates, the remote control and indoor unit receiver are in trouble. If not, the indoor unit is in trouble.
Unable to operate the outdoor unit
Press the TURBO button with the remote control. In 3 minutes, check the voltage between the indoor unit terminal block N(1) and 1.
AC200V ~ AC240V
Problem with the outdoor unit or PCB
No power source displayed.
Problem with the relay (RY71) or PCB
Page 20
5-3 Breakdown diagnosis by symptoms
5-3-1 No Power (completely dead)-Initial diagnosis
1. Checklist : 1) Is input voltage normal? 2) Is AC power linked correctly? 3) Is input voltage of DC regulator IC KA7805 (IC02) normal? (11VDC-12.5VDC) 4) Is output voltage of DC regulator IC KA7805 (IC02) normal? (4.5VDC-5.5VDC) 2. Troubleshooting procedure
Unplug the power cord and plug it after 5 seconds
Press the Power Button on the remote control unit to operate the air conditioner
does not operate
operate
x Check the display board
x Check the indoor unit control board
Check whether two wires of power cord are connected correctly to the terminal block and control board.
Reconnect wires correctly
Check whether the fuse on the control board is normal. F701: 3.15[A]/250[V]
Replace fuse
Check the output of SMPS on the control board. Input power: AC23015%[V] IC02 Input: DC 12[V] IC02 output: DC 5[V]
Replace the control board
x Check the setting temperature
Page 21
Troubleshooting
5-3-2 When the Indoor Unit Fan Does Not Operate. (Initial Diagnosis)
1. Checklist : 1) Is the indoor unit fan motor properly connected with the connector (CN72)? 2) Is the AC voltage correct? 3) Is HALL IC in indoor fan motor properly connected with the connector (CN44)? 4) Is the running capacitor (CR71) properly connected with PCB board? 2. Troubleshooting procedure
After unplugging out the power cord should be reconnected within 5 seconds.
Does the OPERATION lamp blink?
Check as in the procedure "NO power parts"
Yes No
Does the Solid State Relay(SS71) work properly? Test rod location + SS71SS71Yes No
Micom is out of order.
Micom should be replaced
Normal Voltage
Is the supply voltage of the fan motor sufficient? Test rod location PCB CN72 pin #3 and #5 Condition Fan operate Normal Voltage About AC 180V
PCB is out of order.
PCB should be replaced.
Motor Fan-Capacitor is out of order
Replace Motor Fan-Capacitor
Fan motor is out of order.
Fan motor should be replaced.
Page 22
5-3-3 When the Outdoor Unit Does Not Operate. (Initial Diagnosis)
1. Checklist : 1) Is input voltage normal? 2) Is the set temperature of the remote control higher than room temperature in COOL mode? 3) Is the set temperature of the remote control lower than room temperature in HEAT mode? 4) Is the POWER IN connector (CN71) linked correctly? 5) Is the outdoor unit properly connected with the TERMINAL BLOCK connector(N(1), 1, 2, 3)? 2. Troubleshooting procedure
Does the OPERATION lamp blink
Check as in the procedure "No Power parts"
Yes Yes
Room temperature sensor is out of order
Does the timer lamp blink during operation?
PCB should be checked.
Is the power relay RY71 operated by adjusting the room temperature? Test rod location + IC04 Pin No.38 GND Condition RY71 ON
DC 4.8V
Is rating voltage 10% range applied relay between Terminal block No. N(1) and No. 1
Power relay is out of order
Power relay should be replaced.
Outdoor unit is out of order.
! Yes No @
Is the room sensor normal register? 10C 17.96k 20C 12.09k 30C 8.3k
Page 23
5-3-4 When the UP/DOWN Louver Motor Does Not Operate. (Initial Diagnosis)
1. Checklist : 1) Is input voltage normal? 2) Is the UP/DOWN louver motor properly connected with the connector (CN61)? 2. Troubleshooting procedure
Remove power cord and plug in again in approx. 5 seconds.
Is STD lamp blinking?
Check as in the procedure "No Power parts".
Does operation start when swing button of the remote control unit pushed?
Normal
Voltage at pin #57~#60 of micom (IC04) change? (Squarewave)
Micom (IC04) is faulty.
Voltage at pin #16 of IC06(ULN2003A) and #10~#12 of IC08(ULN2003A) change? (Squarewave)
Driver IC06/08 (ULN2003A) is faulty.
UP/DOWN louver motor is faulty.
Page 24
5-3-5 In the HEAT mode, When there is no warm air current. Check this fist;
1. Checklist : 1) Is the set temperature of Remote Control lower than room temperature in Heat mode? 2) Is the Indoor PCB properly connected with the CN71 connector? 2. Troubleshooting procedure
After training on, the heating operation should start in 5 minutes.
Is the number #38 of Micom (IC04) DC 5.0V?
Abnormal Micom
Is the number checking #11 of IC05 (ULN2003A) LOW?
Is the voltage between CN71 #1 and CN71 #5 rating voltage 10% range
Abnormal IC05
Abnormal 4-Way valve of Outdoor Unit. or connecting Cable
Abnormal RY73
4-Way valve should be replaced or connecting Cable Check.
Page 25
5-3-6 Room temperature sensor failure
Indoor unit room temperature sensor error(open or short)
Detach the assembly sensor from the ASS'Y PCB CN43 connector and measure the sensor resistance with an ohmmeter (tester).
Is the sensor resistance value 10K 3% at the room temperature of 25C?
ASS'Y Sensor Replace SENSOR Resistance Value : 20C-12.09k SENSOR Resistance Value : 30C-8.31k SENSOR Resistance Value : 35C-6.94k SENSOR Resistance Value : 40C-5.83k
Connect the sensor to CN43, supply power, and measure the voltage of #1 and #2 of the CN43 connector.
Below 0.5V?
Poor ASS'Y PCB Replace
Over 4.9V?
MICOM Error or Connector(CN43) check
Page 26
5-3-7 Room Pipe sensor failure
Indoor unit heat exchanger temperature sensor error (open or short)
1. Check the assembly condition of the sensor connector(CN43) on the indoor unit Main PCB and if not assembled, reassemble the connector accurately. 2. Detach the room pipe sensor connector(CN43) and check the resistance between connector 3 and 4.
Temperature(C) 25 Resistance Value(Kohm) 14.68 12.Temperature(C) 40 Resistance Value(Kohm) 8.31 6.94 5.83 The data tolerance is 3%. Others
If the above data is not met, replace the room pipe sensor. 3. Assemble the room pipe sensor to PCB, plug in, and check the voltage of connector 3 and 4. If the resistance is below 0.5V or over 4.9V, replace the indoor Main PCB. (short or disconnected in the PCB board)
5-3-8 When the remote control is not receiving.
1. Check if the connector was normally assembled. 2. Put the set in operation and check the voltage of No. 3(+) and No. 2(-) of the main PCB CN91 while operating the remote control. When the voltage descends below 3V, the assembly module PCB is normal and the main PCB is poor. Then replace the main PCB. 3. Replace the assembly display PCB because the module PCB is poor if the voltage between No. 2~3 of CN91 maintains 5V after the remote control starts operation.
Page 27
5-4 PCB Inspection Method
5-4-1 Pre-inspection Notices
1. Check if you pulled out the AC power plug when you eliminate the PCB or front panel. 2. Don't hold the PCB side not impose excessive force on it to eliminate the PCB. 3. Don't pull the lead wire but hold the whole housing to connect or disconnect a connector to the PCB.
5-4-2 Inspection Procedure
1. Check connector connection and peeling of PCB or bronze coating pattern when you think the PCB is broken. 2. The PCB is composed of the 3 parts. q Main PCB Part : MICOM and surrounding circuit, relay, room fan motor driving circuit and control circuit, sensor driving circuit, power circuit of DC12V and DC5V, and buzzer driving circuit. q Display part : LED lamp q Switch part : Switch
5-4-3 Detailed Inspection Procedure
No Procedure Plug out and pull the PCB out of the electronic box. Check the PCB fuse. Supply power. If the operating lamp twinkles at this time, the above 1)~3) have no relation. Inspection Method 1) Is the fuse disconnected? (F701) Cause Overcurrent Indoor Fan Motor Short AC Part Pattern Short of the MAIN PCB
Checking the power voltage. 1) Is the DB71input voltage AC200V~AC240V? Power Cord is fault, Fuse open. Wrong Power Cable Wiring, AC Part is faulty. Switching Trans or Power Circuit is faulty
2) Is the voltage between both terminals of the C102 on the 2nd side of the transformer AC12V 0.5V? 3) Is the voltage between both terminals of OUT and GND of IC02(KA78L05) DC5V 0.5V?
Power Circuit is faulty, Load Short
Press the ON/OFF button and operate TURBO mode. But, exclude the RESERVE operation.
Checking the power voltage. 1) Check the voltage of the relay(RY71) coil(IC05 PIN #11 and GND : 0V, PIN#6 and GND : 5V) during operation(3 minutes after TURBO operation). 2) Check the voltage of both terminals of terminal block 1 and N(1) after 3 minute operation.: AC220V Relay(RY71) Coil Disconnection, IC05 is faulty
Relay(RY71) Contact is faulty
Press the ON/OFF button. 1) Is the voltage over AC180V being imposed on terminal #3 and #5 of the fan motor 1. FAN Speed [High] connector(CN72)? 2. Continuous Operation 2) The fan motor of the indoor unit doesn't run.
Q'TY No.
1 1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2
Code No.
DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112A DB96-03112B
Description
ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP TOTAL ASS'Y-EVAP TOTAL ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS
Specification SH09AWH
Remark SH12AWH
1 Refer to page 40
YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.3S, 2x14 1.5S, 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g, 24BYJ48 ASS'Y STS, PI1.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0.6x320x650 PS ABS-V0 REMOCON
2-1 2-2 2-3
DB63-00850A DB60-00118A DB96-04716A DB96-04716B
3 3-1 3-2 3-3 3-4 3-5 3-6 3-7 3-8 3-8-5 5-1 5-2 5-3 5-9
DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481L DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B
Page 32
Parts List(cont.)
Q'TY No. Code No. Description Specification SH09ZWH AQ09WHWE
SH12ZWH AQ12WHWE
DB94-00454B DB61-01632A DB69-00834A DB61-01634A DB31-00219A DB94-00456A DB97-02075A DB73-00181A DB94-40007A DB96-03112C DB96-03112D
ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON
ASS'Y HIPS EPS HIPS YDK-20S4F8C-1 OD92x635 ASS'Y RUBBER BEARING ASS'Y ASS'Y ABS PVC 1.3S, 2x14 1.5S, 2x14 ASS'Y ABS HIPS PP ABS EPS30 GUM-EPM PM24-600g, 24BYJ48 ASS'Y STS, PI1.0 ASS'Y ASS'Y PS HIPS ASS'Y PP SGCC-M T0.6x320x650 PS ABS-V0 REMOCON
DB63-00850A DB60-00118A DB96-03060A DB96-03257A
DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481 DB92-00536A DB64-00989A DB64-00990A DB97-02064A DB63-00846A DB70-00406A DB61-01638A DB63-00844A DB93-02532B
Refer to page 40
Page 33
ASS'Y-BACK BODY BACK-BODY CUSHION-BACK BODY SUPPORTER-EVAP RH MOTOR-IN ASS'Y-CROSS FAN ASS'Y BOLT-SPECIAL RUBBER-BEARING MOLD-BEARING ASS'Y CYCLE IN ASS'Y CYCLE IN COVER BEARING SPACE-EVAP-LOW ASS'Y-EVAP ASS'Y-EVAP ASS'Y-TRAY DRAIN TRAY-DRAIN BLADE-H BLADE-V STABILIZER CUSHION-TRAY RH RUBBER-CAP ASS'Y-STEPPING-MOTOR ASS'Y DRAIN HOSE CLIP TERMINAL HOSE ASS'Y-CONTROL IN ASS'Y-PANEL FRONT PANEL-FRONT GRILLE-AIR INLET ASS'Y-COVER DISPLAY GUARD-AIR FILTER PLATE-HANGER HOLDER-PIPE COVER TERMINAL ASS'Y-REMOCON ASS'Y HIPS EPS HIPS
Specification
KFR-25G / SWA KFR-35G / SWA
DB94-00457D DB63-00848A DB61-01635A DB61-01636A DB63-00849A DB69-00839A DB73-00180A DB95-20138A DB94-00458B DB61-01715A DB93-02481 DB92-00536B DB64-00989A DB64-00990A DB97-02064A DB63-00846B DB70-00406A DB61-01638A DB63-00844A DB93-02532D
Page 34
Q'TY No. Code No. Description Specification SH09ZWH
(RUSSIA)
SH12ZWH
Page 35
(AUSTRALIA)
Page 36
6-2 Outdoor Unit
17-1 17-2 17-5
17-7 17-9 17-8
19-4 19-3 17-10 19-2 19-1
Page 37
3 3-1 3-17 17-1 17-2 17-3 17-4 17-5 17-6 17-7 17-8 17-9 17-19 19-1 19-2 19-3 19-21 22
DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330A DB90-01330B DB99-00401A DB94-00459C DB94-00459B DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03061A DB96-03172A DB93-02554A DB93-02554B DB61-01642A 2501-001236 2501-001237 2301-001375 DB65-40049E DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB93-00481J DB33-00050A DB35-00029A DB35-00029B DB72-00726A DB72-00726B DB95-00468A DB95-00467A DB95-00501A DB95-00534A DB63-00943A DB63-00999A DB63-00942A DB60-30018A DB96-03062A DB96-03049A DB99-00445A DB99-00413A DB71-00090A DB71-00090B
ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CAPILLARY ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL ASS'Y ASS'Y ASS'Y ASS'Y NR NR
T0.7, SECD-P PP, 378g ASS'Y T0.6, SECC-P PP, 30g T0.6, SECC-P ABS-V0, 66g T1.0, SECC-P T1.0, SECC-P SECC-P, T1.0x95x235 ASS'Y, SGCC-M, T0.6 ASS'Y, SGCC-M, T0.6 SGCC-M T0.6x370x490 ASS'Y ASS'Y YDK-25F6M13E-1 AS+G/F 20%, 422g
SH09AWHX
SH12AWHX
2x24, FP1.5, LOUVER 1x24, FP1.5, LOUVER ASS'Y ASS'Y SGCC-M T0.6x150x250 30Fx450V 35Fx450V 1.5Fx450V
WIRE, ASS'Y MRA99908-9201 MRA99134-9201 FELT+PVC FELT+PVC
45, SANYO 55, SANYO
Page 38
Q'TY No. Code No. Description Specification SH09ZWHX UQ09WHWE
1 NR NR 2x24, FP1.5, LOUVER 1x24, FP1.5, LOUVER ASS'Y ASS'Y SGCC-M T0.6x150x250 30Fx450V 40Fx450V 1.5Fx450V WIRE, ASS'Y RAC12074-9622 RAC12110-9622 FELT+PVC FELT+PVC SEC SEC ASS'Y ASS'Y ASS'Y ASS'Y 1
SH12ZWHX UQ12WHWE
DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330E DB90-01330B DB99-00401A DB94-00459C DB94-00459B DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03580A DB96-03581A DB93-02748A DB93-02748B DB61-01642A 2501-001236 2501-001238 2301-001375 DB65-40049E DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB33-00050A DB35-00030C DB35-00020G DB72-00726E DB72-00726D DB95-00552A DB95-00551A 48D129JU1EL 44B102JX1EL DB63-20002A DB63-10165D DB60-30018A DB99-00453A DB99-00478A DB99-00475A DB99-00477A DB71-00090A DB71-00090B
ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CHECK VALVE ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL
Page 39
DB90-01341A DB63-00847A DB90-01332A DB64-01094A DB64-00992A DB90-01331A DB63-00853A DB90-01330E DB90-01330B DB99-00401A DB94-00459D DB94-00459E DB61-01644A DB97-02225A DB97-02225B DB31-00220A DB67-00397A DB60-30004A DB63-00815A DB63-00763A DB60-30028A DB96-03580A DB96-03581A DB93-02748C DB93-02748D DB61-01642A 2501-001236 2501-001237 2301-001375 DB65-40049H DB65-10046A DB61-00250A DB93-50062C DB93-00481H DB33-00050A DB35-00030C DB35-00030A DB72-00726E DB72-00726D DB95-00543B DB94-00542B 48D129MXAEL 44B102MXAEL DB63-20002A DB63-10165D DB60-30018A DB99-00453A DB99-00478B DB99-00475A DB99-00491A DB71-00090A DB71-00090B
ASS'Y-CABI FRONT GUARD-FAN ASS'Y CABI SIDE LF CABI SIDE LF(COATING) HANDLE LF ASS'Y CABI SIDE RH COVER-CONTROL ASS'Y-BASE ASS'Y-BASE ASS'Y BRACKET VALVE ASS'Y-PARTITION ASS'Y-PARTITION BRACKET-MOTOR ASS'Y PLATE SUPPORT B/M ASS'Y PLATE SUPPORT B/M MOTOR-OUT PROPELLER-FAN NUT FLANGE GROMMET GROMMET NUT WASHER ASS'Y-COND ASS'Y-COND ASS'Y-CONTROL OUT ASS'Y-CONTROL OUT CASE-CONTROL OUT CAPACITOR-COMP CAPACITOR-COMP CAPACITOR-MOTOR TERMINAL-BLOCK CLIP-CAPACITOR HOLDER-WIRE LEAD WIRE ASS'Y LEAD WIRE SOLENOID-ASS'Y OLP OLP SPONGE-FELT COMP CLOTH SPONGE-FELT COMP CLOTH ASS'Y-COMP ASS'Y-COMP COMP COMP GASKET COVER-TERMINAL NUT FLANGE ASS'Y CHECK VALVE ASS'Y CHECK VALVE ASS'Y 4WAY VALVE ASS'Y 4WAY VALVE BAR-STEEL BAR-STEEL ASS'Y ASS'Y ASS'Y ASS'Y SSEC SSEC NR NR
Specification KFR-25W / SWA
T0.7, SECD-P PP, 378g ASS'Y T0.6, SECC-P PP, 30g T0.6, SECC-P ABS-V0, 66g T1.0, SECC-P T1.0, SECC-P SECC-P, T1.0x95x235 ASS'Y, SGCC-M, T0.6 ASS'Y, SGCC-M, T0.6 SGCC-M T0.6x370x490 ASS'Y ASS'Y YDK-25F6M13E-1 AS+G/F 20%, 422g 3 2x24, FP1.5, LOUVER 1x24, FP1.5, LOUVER ASS'Y ASS'Y SGCC-M T0.6x150x250 30Fx450V 35Fx450V 1.5Fx450V WIRE, ASS'Y RAC12074-9622 RAC12054-9622 FELT+PVC FELT+PVC 1
KFR-35W / SWA
Page 40
6-3 Ass'y-Control In(Code No : DB93-02481)
Code No. DB93-02481L
MODEL SH09AWH/EDC, SH12AWH/EDC, SH09ZWH/EDC, SH12ZWH/EDC, AQ09WHWE/FES, AQ12WHWE/FES
Code No. DB93-02481G DB93-02481J KFR-35G/SWA KFR-25G/SWA
DB93-02481C DB93-02481E
SH09ZWH/XSA, SH12ZWH/XSA SH09ZWH/SER, SH12ZWH/SER, SH09ZWH/XFO, SH12ZWH/XFO
DB61-01637A DB93-02482A DB65-00140A DB93-02483A DB61-01639A DB61-00171A DB39-00949A DB39-00147D DB32-00020D DB63-00851A CASE-CONTROL ASS'Y PCB MAIN
FR-4, 120x90 4P FR-1, 30x70 SGCC-M, T1-2 ABS PH M3xL22 TH M4xL16 TH M4xL10 8P 5P 4P(103AT) HIPS 3P
ASS'Y TERMINAL BLOCK ASS'Y S/W & MODULE & DISPLAY PCB PLATE-CONTROL HOLDER-WIRE CLAMP SCREW-MACHINE SCREW-MACHINE SCREW-MACHINE CONNECTOR WIRE S/W & MODULE & DISPLAY CONNECTOR WIRE STEP MOTOR UP/DOWN ASS'Y THERMISTOR WIRE COVER CLAMP POWER CORD
SNA SNA SNA
Page 41
7. Block Diagram
CONTROLLER
IC-MCU
HEAT EXCHANGER SENSOR ROOM TEMPERATURE SENSOR INFRARED SIGNAL RESET CIRCUIT BLADE CONTROL INDOOR FAN MOTOR CONTROL COMPRESSOR CONTROL TEMPERATURE CONTROL TIMER BUZZER CONTROL OUTDOOR FAN MOTOR CONTROL 4-WAY VALVE CONTROL DISPLAY PART OPERATION TIMER TURBO
OSCILLATION CIRCUIT ZERO VOLTAGE DETECT
REMOTE CONTROL
COMPRESSOR CONTROL SIGNAL POWER ON/OFF STEPPING MOTOR CONTROL SIGNAL BUZZER CONTROL SIGNAL OUTDOOR FAN MOTOR CONTROL SIGNAL 4-WAY VALVE CONTROL SIGNAL SSR
TRIGGER SIGNAL
MODE (AUTO, COOL, DRY, FAN, HEAT)
INDOOR FAN MOTOR
TURBO OPERATION
1HR TIMER COMPRESSOR DRIVE OUTDOOR FAN MOTOR DRIVE STEPPING MOTOR DRIVE FLAP BUZZER DRIVE 4-WAY VALVE DRIVE ON, OFF TIMER SELECT STEPPING MOTOR : BLADE UP/DOWN BUZZER COMPRESSOR OUTDOOR FAN MOTOR 4-WAY VALVE
FAN SPEED SELECT (H/M/L)
TEMPERATURE SELECT
DC 5V VOLTAGE REGULATOR
SLEEP SELECT DC 12V SMPS POWER BLOCK BATTERY CHECK
ENERGY SAVING
AC INPUT
Page 42
8. Wiring Diagram
8-1 Indoor Unit
Code No : DB98-15138A
This Document can not be used without Samsung's authorization.
Page 43
8-2 Outdoor Unit
MOTOR CAPACITOR COMP CAPACITOR
FM1 O.L.P
FAN MOTOR OVER LOAD PROTECTOR
SPLIT TYPE
The wonderful practicalism enhances the guality of your living
imagine an air conditioner that takes your breath away
Samsung Air Conditioner
The design incorporates clean-cut front panel that would fit to any interior. An unique color line placed in the front panel gives strong impression. As front panel opens widely upwards it is easy to clean the filters. It is designed for convenience as well as aesthetic.
Flush Front Panel
The flush front panel was realized by moving the front grille to the top of the air conditioner. Cleaning is so easy, simply wipe to recover the brand new look.
Accent Line
Blue line on the white body. The design resembles a refreshing blue sky. The simple design looks great with any interior.
Other Features
Multi-Step Purifying System
The Samsung Multi-Step Air Purifying System removes almost all harmful elements to human beings by using various filters. At the same time, the system also keeps the interior of the air conditioner ultra-clean, so only ultra-fresh air is produced.
Waterfall Heating Air Flow
Auto Changeover
Anti-Bacterial
Molded with an antibacterial formula to suppress proliferation of molds and bacteria, preventing the causes of unpleasant odors. The new Samsung air conditioners feature a wide-angle blade system. In conventional models, the indoor units blade could only open up to 70 degrees, which made it difficult to direct heated airflow to the lower spaces of the room. The wide-angle blade system can open the blades to an angle of 90 degrees. You can control air flow direction vertically and horizontally, providing even distribution of air to any place of the room.
Cooling
Heating
The Auto Changeover automatically selects the operating mode (Cooling or Heating) according to the temperature setting. Thus, when a temperature is selected in the auto mode, the air conditioner heats and cools as required to maintain the set temperature.
Silver Coated Evaporator
The fins of the evaporator are triple coated with environmentally friendly materials (2 layers of chrome-free silica, 1 layer of Silver coating) to ensure efficient removal of condensation and to guarantee the production of clean and fresh air.
Activated carbon is incorporated in the filter, efficiently absorbing cigarette smoke, pet odors and other unpleasant smells.
Rapid Cooling & Heating
Energy Efficient and Quiet Fan
Conventional
Catechin filter
Catechin, extracted from green tea, is contained in the filter and deactivates captured bacteria and unpleasant odors.
Samsung
Silver Coated filter
The silver-nano coating applied to the filter, serves to trap and remove dust particles to provide you fresher and healthier air. Everyone wants to have the room temperature in the ideal state when they come home. Especially in severe hot or cold weather. With the exceptional technical characteristics and superior quality features, the new Samsung air conditioners maximize the speed of cooling and heating to reach the set temperature in a short time. In the outdoor unit, the new propeller fan has better performance characteristics due to its trianglular hub shape, resulting in enhanced energy efficiency and fan capacity, greater hot temperature resistance, and quieter operation.
Samsungs Forte Series includes the Air Purifying System built inside.
The Most Silent Air Conditioner, Forte Catechin Filter Double Blade System Easy Detachable & Washable Grille
Catechins Anti-bacterial Effect
Staphylococcus aureus, methicillin-resistant Staphylococcus aureus (MRSA), Escherichia coli, etc. are deactivated.
Catechins Deodorizing Effect
Non-Inverter
The causes of odors from pet odor to cigarette smoke (ammonia, acetaldehyde, hydrogen sulfide, etc.) can be minimized and deodorized by physical decomposition and absorption.
Deodorizing Filter
Samsung implemented the innovative double blade in the NEW Classic Series, which can control the airflow even more effectively, distributing air in the desirable direction. With widened angles, this revolutionary blade system offers reliable, controllable comfort all year round while ensuring optimum air conditioner performance.
Changing the grille used to be a very irritating chore. With Samsungs Classic Series however, you will never experience such problems again. Newly designed grilles can be easily detached from the indoor unit for regular cleaning, providing extra convenience for users as they have to clean the grille regularly according to the air conditioners operational manual.
*Lowest noise level of an indoor unit for Non-Inverter / R410A / Heat Pump
Outdoor Installation Pipe
Activated carbon is incorporated in the filter, efficiently absorbing cigarette smoke, pet odors, and other unpleasant smells, replacing them with clean, refreshing air.
ngth g Le Pipin (15m) 30m
Improved Low Temperature Operation
Easy Handle for Convenience During Transporting, Unloading, etc
Bigger Heating Capacity
Classic(SH12AWH)
nce iffere ) ht D 5m(8m 1 Heig
Three drainage holes Extended drainage channels Above features apply for specific models only
Conventional SH12ZWH - 5% improvenment(4.0kw)
The connection pipe is extendable up to 30 meters in length and up to 15 meters in height (18,000~24,000Btu/h) [or 15 meters in length and 8 meters in height (9,000~12,000Btu/h)]. So, there is great flexibility in the choice of location for the Outdoor unit.
Improved heating capacity ultimately results in improved performance in low temperatures. Moreover, the new base structure of the outdoor unit includes three drainage holes and extended drainage channels, providing better protection for the cabinet against excess water, freezing, and rust. An automatic defrosting algorithm developed specifically for cold countries allows smooth heating operation with outdoor temperatures below 0C.
The lightweight and compact outdoor unit is equipped with a handle for convenience during transporting, unloading, etc. Because the outdoor unit can be carried with ease, installation is quick and simple.
Samsungs new air conditioners ensure a higher heating capacity. By applying cutting edge technologies, Samsung improved the heating capacity by as much as 10% compared to previous models, allowing our customers to enjoy even more warm air.
Forte Inverter (Europe)
Forte (Europe)
Model Number
9000 Btu/h 12000 Btu/h 18000 Btu/h 24000 Btu/h
AQV09FA (Inverter) AQV12FA (Inverter) AQV18FA (Inverter) AQV24FA (Inverter)
Cooling Only
Heat Pump
AQ09FA AQ12FA AQ18FA AQ24FA
Features
Good Morning Mode Smart Inverter Silver Coated Filter Silver Coated Evaporator Deodorizing Filter Catechin Filter Dehumidification Turbo Mode / Sleep Mode Timer Auto Restart Auto Changeover Auto Wind Auto Grille
Catechin Filter
Tags
CDE-7874EB Xr1850NF 450 XC-W Aspire 5630 UE37C6820US Rique Dora MZ-2000 Milestone 2 Globalmap 100 Wide Zoom 37S86BD LE26A457 KD-R411 743NX Babyface Laserjet 5100 Fo-a660 SWF-P10 Alice AVC-A1SE CPD-17SF2 BJC-2000 AR-M277 All-IN-ONE Nokia 2125 Deere 6230 System LE37S8 S-MAP 93ST-A Korg X5DR Silence Omron E5CN 9512 TS STR-SE581 DB415 Yamaha P150 FA1026hydr America SLV-SE800B XV-Z1E Command Unit Review Extensa-5620 VA712B GT-S5233W LV-104U 4 5 IC-GM651 Picturemate Zoom B1X F14932DS Reverb AMP RC299 Thinkpad T21 MFC-3320CN Iwork 08 16 II TH-50PHD3 Classic-2005 YP-S3 100 Plus Fo-610 3175 WX LC-19A1E Gz-hd7 Audio 5060 CFW-10 CCD-TR315E CMX100II BDP-N460 Cle USB KM-2560 CU-L34dbe5 MW500 GEB-7 Express Plus SUP021R Recorder PCV-LX900 St 1400 Z8612 IS RNS149 Deluxe CDX-GT450S CDC A01 I8000 Juno ST DSC-V3 AD-44 LX8500W 90070 BDP1400 CQ-VW100U WFT11C65EF Printer 42LB5RT Omnibot HT-C350 NN-K453 SE4351S
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101