Seiko V657
About Seiko V657Here you can find all about Seiko V657 like manual and other informations. For example: movement.
Seiko V657 manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Seiko V657 please write about it to help other people. [ Report abuse or wrong photo | Share your Seiko V657 photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Seiko V657, size: 849 KB |
Seiko V657
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
Cal. V657
INSTRUCTIONS BEDIENUNGSANLEITUNG INSTRUCTIONS ISTRUZIONI INSTRUCCIONES INSTRUES
(S. 16) (P. (P. (P. (P. (81 29) 42) 55) 68) )
English
You are now the proud owner of a SEIKO Analogue Quartz Watch Cal. V657. For best results, please read the instructions in this booklet carefully before using your SEIKO Analogue Quartz Watch. Please keep this manual handy for ready reference. Sie sind jetzt Besitzer einer SEIKO Analog-Quarzuhr Kal. V657. Bitte lesen Sie diese Bedienungsanleitung vor Verwendung der Uhr sorgfltig durch und heben Sie sie gut auf. Vous voici lheureux propritaire dune montre quartz analogique SEIKO Cal. V657. Pour obtenir dexcellentes performances de cet article SEIKO, veuillez lire attentivement cette brochure que vous conserverez pour toute rfrence ultrieure. Siete ora in possesso di un orologio SEIKO Analogico al Quarzo Cal. V657. Per ottenere i migliori possibili risultati dal Vostro orologio, leggere attentamente le istruzioni di questo manuale prima di utilizzare il Vostro orologio SEIKO analogico al quarzo. Conservare poi il manuale stesso per ogni qualsiasi eventuale futuro riferimento. Enhorabuena por su adquisicin de un reloj SEIKO analgico de cuarzo Cal. V657. Para ptimo resultado, lea detenidamente las instrucciones de este folleto antes de usar el reloj. Guarde este manual para consulta posterior. Voc pode sentir-se orgulhoso de possuir um Relgio SEIKO Quartz Anlogo Cal. V657. Para obter os melhores resultados, leia atentamente as instrues contidas neste opsculo antes de usar o seu Relgio SEIKO Quartz Anlogo. Queira conservar este manual para referncias futuras. V657
ENGLISH English
CONTENTS
Page ADJUSTING THE HAND POSITION... TIME/CALENDAR SETTING... STOPWATCH.... TACHYMETER... NOTES ON USING THE WATCH... BATTERY CHANGE.... SPECIFICATIONS.... 15
6 For the care of your watch, see TO PRESERVE THE QUALITY OF YOUR WATCH in the attached Worldwide Guarantee and Instruction Booklet.
CAL. V657
STOPWATCH q Three small STOPWATCH hands q Measures up to 60 minutes in 1/10 second
increments.
q Split time measurement q Tachymeter function (for models with
tachymeter scale on the dial)
TIME/CALENDAR q Hour, minute and second hands and date
ADJUSTING THE HAND POSITION
q Before setting the time, be sure to check that the STOPWATCH hands are in 0 position when the stopwatch is reset. (For resetting the stopwatch, see STOPWATCH) q If any of the STOPWATCH hands does not return to 0 position, follow the procedure below.
STOPWATCH 1/10 second hand
STOPWATCH minute hand
CROWN w
Pull out to second click. Press repeatedly to reset STOPWATCH 1/10 second hand to 0 position. Press repeatedly to reset STOPWATCH second and minute hands to 0 position. Push back in to normal position.
STOPWATCH second hand
w CROWN
* Hands move quickly if the respective buttons are kept pressed.
TIME/CALENDAR SETTING
CROWN Pull out to first click and turn clockwise until the previous days date appears. w Pull out to second click when Second hand is at the 12 oclock position. w Turn clockwise until the desired date appears. w Set Hour and Minute hands. w Push back in to normal position in accordance with a time signal.
Second hand Hour hand Minute hand
STOPWATCH
q The measured time is indicated by small STOPWATCH hands that move independently of the center hands.
HOW TO READ THE HANDS q Ex. : 15 minutes and 10.6 seconds
q Movement of STOPWATCH 1/10 second hand After the measurement exceeds 1 minute, the STOPWATCH 1/10 second hand stays at the 0 position while the stopwatch is counting. When the measurement is stopped or split time is being measured, it indicates the 1/10 seconds measured.
STOPWATCH OPERATION
Start / Stop / Restart
Standard measurement
Reset / Split / Split release
* Restart and stop of the stopwatch can be repeated by pressing button A. * Measurement and release of split time can be repeated by pressing button B.
Accumulated elapsed time measurement
RESTART
Split time measurement
START 8
SPLIT RELEASE
TACHYMETER [for models with tachymeter scale on the dial]
To measure the hourly average speed of a vehicle:
Tachymeter scale: 90
1 Use the stopwatch to determine how many
seconds it takes to go 1 km or 1 mile.
2 Locate the second marker on the main dial
which corresponds to the number of seconds measured. The number on the tachymeter scale indicates the average speed per hour.
* For the models with the tachymeter scale around the small dial at the 6 oclock position, read the tachymeter scale which the STOPWATCH second hand points to.
q Tachymeter scale can only be used to measure average speed when time required is up to 60 seconds. If the measuring distance is extended to 2 km or miles or shortened to 0.5 km or miles and STOPWATCH second hand indicates 90 on the tachymeter scale: 90 (tachymeter scale figure) x 2 (km or miles) = 180 km/h or mph 90 (tachymeter scale figure) x 0.5 (km or miles) = 45 km/h or mph
STOPWATCH second hand: 40 seconds
q Ex. : 90 (tachymeter scale figure) x 1 (km or mile) = 90 km/h or mile/h
To measure the hourly rate of operation:
Tachymeter scale: 180
1 Use the stopwatch to measure the time required to complete 1 job.
which corresponds to the number of seconds measured. The number on the tachymeter scale indicates the average number of jobs accomplished in one hour.
q If 15 jobs are completed in 20 seconds: 180 (tachymeter scale figure) x 15 jobs = 2700 jobs/hour
STOPWATCH second hand: 20 seconds
q Ex. : 180 (tachymeter scale figure) x 1 job = 180 jobs/hour
NOTES ON USING THE WATCH
q The STOPWATCH minute hand moves in correspondence with the STOPWATCH second hand.
q Before setting the time, be sure to stop and reset the stopwatch. q Do not set the date between 9:00 p.m. and 1:00 a.m. Otherwise, the date may not change properly. If it is necessary to set the date during that time period, first change the time to any time outside it, set the date and then reset the correct time. q When setting the hour hand, check that AM/PM is correctly set. The watch is so designed that the date changes once in 24 hours. Turn the hands past the 12 oclock marker to determine whether the watch is set for the A.M. or P.M. period. If the date changes, the time is set for the A.M. period. If the date does not change, the time is set for the P.M. period. q When setting the minute hand, advance it 4 to 5 minutes ahead of the desired time and then turn it back to the exact time. q Do not press any button with the crown at the second click. Otherwise, the STOPWATCH hands move and resetting them is made necessary.
q The STOPWATCH 1/10 second scale and hand differ in design and shape depending on the model. q Do not pull out the crown while the stopwatch is counting. If it is pulled out, the stopwatch operation cannot be made. q When the stopwatch is reset, it takes up to 40 seconds for the STOPWATCH second and minute hands to return to 0 position.
HOW TO OPERATE THE SCREW LOCK TYPE CROWN (for models with screw lock type crown)
q To unscrew the crown: Turn the crown counterclockwise. Then, pull it out for time/calendar setting or for adjusting the STOPWATCH hand position. q To screw in the crown: With the crown at the normal position, turn it clockwise while pressing it.
BATTERY CHANGE
The miniature battery which powers your watch should last approximately 2 years. However, because the battery is inserted at the factory to check the function and performance of the watch, its actual life once in your possession may be less than the specified period. When the battery expires, be sure to replace it as soon as possible to prevent any malfunction. For battery replacement, we recommend that you contact an AUTHORIZED SEIKO DEALER and request SEIKO SR920SW battery.
* If the stopwatch is used for more than 60 minutes a day, the battery life may be less than 2 years.
WARNING
q Do not remove the battery from the watch. q If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor immediately.
CAUTION
q Never short-circuit, heat or otherwise tamper with the battery, and never expose it to fire. The battery may burst, become very hot or catch fire. q The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the battery. 13
Necessary procedure after battery change
q When the battery is replaced with a new one, the information stored in the built-in IC does not correspond with the time actually displayed. Before using the watch, therefore, be sure to reset the circuit following the procedure below.
* In case any of the hands should move improperly, follow the procedure below to adjust the hand movement.
Pull out to second click.
Press and hold at the same time for 2 seconds.
* STOPWATCH second hand turns half a revolution counterclockwise and then returns to where it was, while STOPWATCH 1/10 second hand turns a full revolution clockwise and stops.
Press repeatedly to reset STOPWATCH 1/10 second hand to 0 position.** Press repeatedly to reset STOPWATCH second and minute hands to 0 position.** Turn to set the time, and then push back in to normal position.
** The hands move quickly if the respective buttons are kept pressed.
SPECIFICATIONS
5 Frequency of crystal oscillator. Loss/gain (monthly rate).. Operational temperature range. Driving system.. Display system Time... Date... Stopwatch.. 32,768 Hz (Hz = Hertz. Cycles per second) Less than 20 seconds at normal temperature range (5 C ~ 35 C) (41 F ~ 95 F) 5 C ~ +50 C (23 F ~ 122 F) Step motor, 3 pieces Hour, minute and second hands Displayed in numerals. Minute, second and 1/10 second hands The stopwatch measures up to 60 minutes in 1/10 second increments. Miniature silver oxide battery SEIKO SR920SW, 1 piece C-MOS-LSI, 1 piece
Battery.. IC (Integrated Circuit)..
* The specifications are subject to change without prior notice for product improvement.
Tags
GR-D200us-gr-d200 Kxtg2512FX Xv-DV580 Reference Roland SH09 Urc-7740 EKC5120 El52250 Unique PDP2556 PA 50 Handheld Server MC-767W Tvcr13F1 WD-J63B NVD-V004 DTH6000 DC725KA DMR-E55 AV220D2 CDA-9885R CLD-700 KX-TG2314 VGN-NS21m P PJ-TX300E Version 14 Samsung NC10 Stick Xv-n332 Gpsmap 62 KLV-21SR2 Eu 340 MDR-IF120K NV-GS24EG IC-756PRO ROC 56 4830 NET 120 B DST-SP1 KCE-300BT Chicago SW Dslr-A200K Globalnav 12 Aquila-GV650 PRO X2 Samson C01U EUR7722X90 GR-DX28E GCE-8526B DTH252E XLT1200-2001 8 0 Asus P5AB Deskjet 6540 KX-TG2237 L3126 S-21W Mwdgce-22 4 RCL-10 ES250PW Fostex VM04 PB6100 UX-B800 NE-1037 P4B533-V DWC283BLS SA-VA10 A E RHT387H SDX-900V Music DNC60 UX-F34CL 3000 XL LV220D MAX-DX75 Rocket US-1641 ESD 767 QW1450HT AX-890 Ignition MA09AH1 Deluxe 900 GM-V42c-gm-v42 Toshiba QF10 KLX125 Series Movement KDC-4047UM LC-20SD5e S Forge XP DHT-FS3 Digimax 202 U O GR-349sqfa MRF-250 ZE-MC292 SD870 IS C1100
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101







