Reviews & Opinions
Independent and trusted. Read before buy Sharp EL-531RH!

Sharp EL-531RH


Bookmark
Sharp EL-531RH

Bookmark and Share

 

Sharp EL-531RHAbout Sharp EL-531RH
Here you can find all about Sharp EL-531RH like manual and other informations. For example: review.

Sharp EL-531RH manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Sharp EL-531RH please write about it to help other people.
[ Report abuse or wrong photo | Share your Sharp EL-531RH photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (Romanian)
Sharp EL-531RH, size: 620 KB
Download (English)
Check if your language version is avaliable.
Most of manuals are avaliable in many languages.

 

Sharp EL-531RH

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 2. Page 1 of 1. Average Rating:
energylevel 11:08pm on Friday, August 20th, 2010 
Great value / easy to use Do not let the price fool you, this calculator can do it all.
nicholashill 6:13pm on Saturday, June 12th, 2010 
Good calculator Bought this calculator for my daughter, as it was the one recommended by her school.

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

MODEL NO: SHARP EL-531VH or EL-531RH (ADVANCED D.A.L) STEP ONE: Select the statistics mode. Select MODE, this is done by pressing 2ndF followed by the DRG button and then select option 1 which is STATX. The modes are generally written on the top of the calculator. Make sure STAT x is on the screen. STEP TWO: Input the Data The simplest case is one variable. To input 3, 5, 4, 7, 1 you must do the following: 3[M+] 5[M+] 4[M+] 7[M+] 1[M+] Each time you enter a unit of data the calculator shows the count of the data entered so far. So if youve done the above, your calculator should show 5 or n=5. STEP THREE: Statistical Calculations x is the sample mean: [RCL] [4] xn the population standard deviation: [RCL] [6] xn1 the sample standard deviation: [RCL] [5] x2 the sum of squares of the sample data: [RCL] [+/-] x the sum of the sample data: [RCL] [.] n the number of items in the sample: [RCL] [0] STEP FOUR: Clearing the Data In order to start calculations on a new dataset the current memory must be cleared by selecting CA. This is done by pressing SHIFT and then DEL. STEP FIVE: Getting out of STAT Mode This is done by selecting 2ndF, MODE and then option 0 on the calculator which is NORMAL. Try the following: Try to get the mean and standard deviation of 37.75, 38, 37, 38.5, and 37.5. You should get a mean of 37.75 and a standard deviation of 0.5.
MODEL NO: SHARP EL-506W or EL-546W or EL-531W STEP ONE: Select the statistics mode. This is done by pressing the MODE button, selecting STAT which is option 1 and then select SD which is option 0 on this calculator.
STEP TWO: Input the Data The simplest case is one variable. To input 3, 5, 4, 7, 1 you must do the following: 3[M+] 5[M+] 4[M+] 7[M+] 1[M+] Each time you enter a unit of data the calculator shows the count of the data entered so far. So if youve done the above, your calculator should show 5 or n=5. STEP THREE: Statistical Calculations x is the sample mean: [RCL] [4] xn the population standard deviation: [RCL] [6] xn1 the sample standard deviation: [RCL] [5] x2 the sum of squares of the sample data: [RCL] [+/-] x the sum of the sample data: [RCL] [.] n the number of items in the sample: [RCL] [0] STEP FOUR: Clearing the Data In order to start calculations on a new dataset the current memory must be cleared by selecting CA. This is done by pressing SHIFT and then DEL. STEP FIVE: Getting out of STAT Mode This is done by selecting 2ndF, MODE and then option 0 on the calculator which is NORMAL. Try the following: Try to get the mean and standard deviation of 37.75, 38, 37, 38.5, and 37.5. You should get a mean of 37.75 and a standard deviation of 0.5.
MODEL NO: CASIO fx-83 WA STEP ONE: Select the statistics mode. This is done by pressing the MODE button and selecting SD which is option 2 on this calculator. STEP TWO: Input the Data The simplest case is one variable. To input 3, 5, 4, 7, 1 you must do the following: 3[M+] 5[M+] 4[M+] 7[M+] 1[M+] STEP THREE: Statistical Calculations x is the sample mean: [SHIFT] [1] [=] xn the population standard deviation: [SHIFT] [2] [=] xn1 the sample standard deviation: [SHIFT] [3] [=] x2 the sum of squares of the sample data: [ALPHA] [(-)] [=] x the sum of the sample data: [ALPHA] [ ,,,] [=] n the number of items in the sample: [ALPHA] [hyp] STEP FOUR: Clearing the Data In order to start calculations on a new dataset the current memory must be cleared. This is done by pressing ALPHA, then MCL and nally =. STEP FIVE: Getting out of STAT Mode This is done by selecting MODE and then COMP which is option 1. Try the following: Try to get the mean and standard deviation of 37.75, 38, 37, 38.5, and 37.5. You should get a mean of 37.75 and a standard deviation of 0.5.

MODEL NO: CASIO fx-83 ES STEP ONE: Select the statistics mode. This is done by pressing the MODE button, then selecting STAT which is option 2 on this calculator and then 1-VAR which is option 1 on this calculator. STEP TWO: Input the Data The simplest case is one variable. To input 3, 5, 4, 7, 1 you must do the following: 3[=] 5[=] 4[=] 7[=] 1[=] STEP THREE: Statistical Calculations x is the sample mean: [AC] [SHIFT] [1] [5] [2] [=] xn the population standard deviation: [AC] [SHIFT] [1] [5] [3] [=] xn1 the sample standard deviation: [AC] [SHIFT] [1] [5] [4] [=] x2 the sum of squares of the sample data: [AC] [SHIFT] [1] [4] [1] [=] x the sum of the sample data:[AC] [SHIFT] [1] [4] [2] [=] n the number of items in the sample: [AC] [SHIFT] [1] [5] [1] [=] STEP FOUR: Clearing the Data In order to start calculations on a new dataset the current memory must be cleared. This is done by pressing SHIFT, then CLR which is 9 on the calculator then press MEMORY which is option 2, then press YES which is = and nally AC. STEP FIVE: Getting out of STAT Mode This is done by selecting MODE and then COMP which is option 1.
MODEL NO: CASIO fx-83MS or fx-85MS STEP ONE: Select the statistics mode. This is done by pressing the MODE button, then selecting SD which is option 2 on this calculator. STEP TWO: Input the Data The simplest case is one variable. To input 3, 5, 4, 7, 1 you must do the following: 3[=] 5[=] 4[=] 7[=] 1[=] STEP THREE: Statistical Calculations x is the sample mean: [AC] [SHIFT] [2] [1] [=] xn the population standard deviation: [AC] [SHIFT] [2] [2] [=] xn1 the sample standard deviation: [AC] [SHIFT] [2] [3] [=] x2 the sum of squares of the sample data: [AC] [SHIFT] [1] [1] [=] x the sum of the sample data:[AC] [SHIFT] [1] [2] [=] n the number of items in the sample: [AC] [SHIFT] [1] [3] [=] STEP FOUR: Clearing the Data In order to start calculations on a new dataset the current memory must be cleared. This is done by pressing SHIFT, then CLR, then SCL which is option 1 and nally =. STEP FIVE: Getting out of STAT Mode This is done by selecting MODE and then COMP which is option 1.

 

Tags

BIG 655 SPH-B6550 DR-119E Multithermo 50 Multi-piattaforma 2 Model 2223 KH 2074 XE-A127 KX-TG1311BL TS-950SDX DTV-3200 NV-DS77 MPX-3 ESF66810X FL632C ETX-80AT-TC 9600 GT 280820 Casio 2329 SGH-E340 BMS641X L32H01EA S9-HD 320PX JBL J50 HT-R557 PAC02 FX-3650P 37AM-23S 24S Ls-color MDX 2100 Ipower 680 V-MAX-1998 Volvo 345 Lancia Musa Netscanev30 KS-5200HT HTC 8125 Uc 200B IC-720A CLP-310 XAA VI-12-18 Light 2 HZL35Z EP-6VBA LG 900B EMP100 P-660R Vivicam 2500 47PFL9603D DSX-80 WSA80 HS805 BO6040 - 2003 WS9635 Ceno 305 AX-R551BK NC4400 KX-T4550B VG510S PS142KB MX-J300 Review 55PP935299 42PF5331 Elura 90 Edirol R1 RMR939P YZF-R6-2006 CTK-810 WL-500G-C SCX-4521 Appliance CQ-DFX783N BX1220 Extensa 5430 Compass Freeline S AC-VQ11 A096UQ Up3 Diplomacy 44 AF-4 RX-V1000 NN-A883 Watch HCD-461 Blade PC XE-A201S 14PT1356 01 AVR 5500 PSR-E303 Kxtga641EX RY52004 MD 4689 VGN-NR31z S WF-A1113BC 125 S2 Duo Trio CF-21F80KX Isight

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101