Sharp KC-6400E 6500E
|
|
Bookmark Sharp KC-6400E 6500E |
About Sharp KC-6400E 6500EHere you can find all about Sharp KC-6400E 6500E like manual and other informations. For example: review.
Sharp KC-6400E 6500E manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Sharp KC-6400E 6500E please write about it to help other people. [ Report abuse or wrong photo | Share your Sharp KC-6400E 6500E photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Sharp KC-6400e/6500E, size: 4.0 MB |
Related manuals Sharp KC-6400e/6500E Annexe 2 Sharp KC-6400e/6500E Annexe 1 |
Sharp KC-6400E 6500E
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents
KC-6400E KC-6500E
KC-6400E
KC-6500E
Free standing type Freistehende Ausfhrung Typ wolnostojcy
*Plasmacluster is a trademark of Sharp Corporation.
POLSKI
OCZYSZCZACZ POWIETRZA INSTUKCJA OBSUGI
DEUTSCH
LUFTREINIGER BEDIENUNGSANLEITUNG
ENGLISH
AIR PURIFIER OPERATION MANUAL
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS.. E-2 WARNING... E-2 CAUTIONS CONCERNING OPERATION... E-3 INSTALLATION GUIDELINES... E-3 FILTER GUIDELINES... E-3 PLEASE READ BEFORE OPERATING YOUR NEW AIR PURIFIER. E-4 FEATURES... E-5
PART NAMES... E-6 ILLUSTRATIVE DIAGRAM... E-6 BACK... E-7 INCLUDED... E-7 MAIN UNIT DISPLAY.. E-8 PREPARATION.. E-10
ENGLISH DEUTSCH
FILTER INSTALLATION.. E-10 POUR WATER INTO THE TANK... E-12
OPERATION... E-13 POWER ON/OFF BUTTON.. E-13 ION SHOWER MODE OPERATION... E-13 MODE SELECTION BUTTON... E-14 HUMIDIFY AND CLEAN AIR MODE.. E-14 RUNNING CLEAN AIR MODE ONLY.. E-15 PLASMACLUSTER ION MODE.. E-15 LIGHTS ON/OFF... E-15 CARE AND MAINTENANCE... E-16 MAIN UNIT... E-16 TANK... E-16 SENSORS... E-16 FILTER CLEANING.. E-17 WASHABLE ACTIVE CARBON FILTER CARE. E-17 MIST TRAY... E-18 MIST FILTER... E-19
FILTER REPLACEMENT GUIDELINES... E-20
TROUBLE SHOOTING.. E-21 SPECIFICATIONS.. E-22 INFORMATION ON PROPER DISPOSAL.. E-23
Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: Important Safety Instructions. After reading this manual, retain it in a convenient location for future reference.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
Read all instructions before using the unit. Use only a 220-240 volt outlet. Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened. Periodically remove dust from the power plug. Do not insert fingers or foreign objects into the intake or air outlet. When removing the power plug, always hold the plug and never pull the cord. Electrical shock and/or fire from short circuit may occur as a result. Do not remove the power plug when your hands are wet. Do not use this unit near gas appliances or fireplaces. When pouring the water into the Tank, when cleaning the unit and when not using the unit, be sure to unplug the power cord. Electrical shock from bad insulation and/or fire from short circuit may occur as a result. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard. Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a bathroom. Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior. Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs. When carrying the Main Unit, please remove the Tank and MIST Tray and hold the Handles on both sides. Do not drink in jest the water in the MIST Tray or Tank. It may cause illness. Change the Tank water every day with fresh tap water. Keep inside the Tank clean. (See Tank maintenance E-12) Leaving water in the Tank will result in mold, bacteria, and bad odours. In rare cases, this bacteria cause harmful physical effects. When not in use, dispose the water in the Tank and MIST Tray. Leaving water in the Tank and MIST Tray will cause mold and bacteria.
NOTE - Radio or TV Intreference
If this air purifier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation distance between the unit and radio/TV receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
CAUTIONS CONCERNING OPERATION
Do not block the intake and air outlet. Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. Do not lay the unit down when using. Always hold the handles on both sides of the unit when moving it. Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury. Do not operate the unit without the filter. Do not wash and reuse HEPA filter. Not only does it not improve filter performance, it may cause electric shock or malfunction. Clean the exterior with a soft cloth only. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result. The frequency of maintenance (descaling) will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary.
INSTALLATION GUIDELINES
During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipments. Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur. Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. (Use under appropriate conditions between 5 and 35C in the room.) Place on a stable surface with sufficient air circulation. When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly. When placing the unit on an uneven surface, the water may leak from the Tank. Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. Leave about 60cm of space from the ceiling and wall. The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.
FILTER GUIDELINES
Follow the instructions in this manual for correct care and maintenance of the filters.
Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through a Washable Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through, a new HEPA Filter can remove 99.97% of dust particles, of as small as 0.3 microns. The Washable Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. (Odour elements are absorbed by HEPA Filter as well.) Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected. If the odour persists, then the filters are fully expended and it is necessary to purchase the optional replacement filter.
The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot completely remove the odour. (for example, odours from construction materials and pet odours). It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Washable Active Carbon Filter
(Common illustration has used KC-6500E)
FEATURES
New Air Purifier with "Humidifying" ability beyond the "Two-in-one" effect
"Synergy" of humidification and Plasmacluster ion realize the more powerful deodorization and eliminating of airborne dust, mold, or microbes. 1.Simultaneously generating the Plasmacluster ions and vaporized mist realize the longer life of ions and higher performance of purification. (Not available to get this effect from separate Humidifier and Air Purifier.) 2. Powerfully decompose and remove the airborne microbes or house dust. 3. Effectively eliminating of static electricity which tend to be caused in a dry environment. 4. Powerful deodorizing - not only the airborne odour but the adherent one which is inside of the fabric of clothes. 5. Provide the appropriate humidity in the room, and controls the activity of viruses in the dry room. 6. Usual air purifying operation is available by selecting humidify off mode.
Powerful Humidifying Ion Shower Operation
Enhanced Ion Shower operation with humidification releases concentrated Plasmacluster ions by repeating its airflow cycles between strong and gentle, effectively removes the airborne dust, pollen, mold, and allergen.
Dual Filtering System
1) Washable Active Carbon Filter Collect the large dust particles at the surface, and absorbes odour elements. Washable to maintain optimum deodorization performance. 2) HEPA (High Efficiency Particulate Air) Filter with Microbial control. High efficiency filter can remove the dust particles as small as 0.3 microns.
PART NAMES
ILLUSTRATIVE DIAGRAM
(KC-6400E)
Control Panel Air Outlet Temperature / Humidity Sensor Odour Sensor
HEPA Filter (white) Washable Active Carbon Filter (black) Main Unit
Front Panel
(KC-6500E)
Control Panel Air Outlet Odour Sensor Temperature / Humidity Sensor Dust Sensor Dust Sensor Filter HEPA Filter (white) Washable Active Carbon Filter (black) Filter Support Main Unit Front Panel
Handle
(2 locations left and right) (left and right/bottom side)
Air Inlet
Air Outlet
Tank Handle Date Label Tank
Tank Cap
Power Cord Power Plug
Float MIST Filter MIST Tray
(Shape of plug depends on country.)
(2 locations left and right)
(left and right/bottom side)
Tank Handle Tank
Date Label
Float MIST Filter
MIST Tray
INCLUDED
Operation manual
MAIN UNIT DISPLAY
Clean Air Mode
Mode Selection Button Plasmacluster ON/OFF Indicator Light (green) Operation Indicator Light(green)
ION SHOWER Mode Button
(Humidification + Plasmacluster)
Plasmacluster ON/OFF Button Plasmacluster Indicator Light
Colour Mode
Ion SHOWER Cycle of light and shade blue Plasmacluster ON Plasmacluster OFF Light off
CLEAN-SIGN Light
Air of room
red orange green
the colour of CLEAN-SIGN DETERMINING THE BASE IMPURITY RATE
ION SHOWER Indicator Light (blue.green)
Humidify Mode
Mode Selection Button
Operation Indicator Light(green)
MIST Filter Indicator Light (red)
Informs you when you must clean your MIST Filter. After cleaning
MIST Filter Reset Button
The Mist Filter Indicator Light turns off.
Water Supply Indicator Light (red)
Informs you when the tank needs to be refilled with water.
green)
Humidity Indicator Light (green)
Displays a rough measure of the current level of indoor humidity. (Inputting your preferred humidity settings is not allowed) The unit will check the current level of humidity for one minute immediately after the power is turned ON, during which time numbers 30 - 70 flash sequentially. (Ex.) At 50% humidity
Power ON/OFF Button
PREPARATION
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in the plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
Install the filters
1 Remove the Front Panel.
Push in the hooks, then pull the Front Panel.
Front Panel Hook
HEPA 1 Place theunit. Filter within the main
Please make sure that the HEPA Filter is placed in proper orientation.
Do not install the filter backwards or the unit will not operate properly.
HEPA Filter
2 Remove the Filter Support.
Push in the hooks on top , then pull the Filter Support.
(Only KC-6500E)
2 Place the Washable Active Carbon Filter into the main
Filter Support
Remove the Washable Active Carbon Filter (black) and HEPA Filter (white) from the plastic bags.
HEPA Filter Wachable Active Carbon Filter
Fit the Washable Active Carbon Filter to the tab on the top of the main unit.
Fit the band to the tab facing toward you in the direction indicated by the arrow, and insert fully.
band(blue)
(At open) The filter may sometimes discharge deodorant powder, but such discharge does not affect deodorizing performance.
Band(blue)
Replace the Front Panel.
Place the Filter Support through the bands (2 places) located at the corners of the Washable Active Carbon Filter.
Wa s h a b l e A c t i v e Carbon Filter Front Panel Filter Support
Replace the Filter Support and the Washable Active Carbon Filter back to the main unit.
in 4 Fillthethe usage start date on Date Label.
Use the date as a guide for the Filter Replacement schedule.
Pour water into the Tank
This product can be used as an air purifier without putting water in the tank.
Tank Handle
Hold the tank handle and remove the tank.
2 Remove the tank cap and pour water.
Use drinkable tap water. (Generally speaking, tap water is sterilized with chlorine to suppress propagation of bacteria.) Change the tank water every day with fresh tap water.
supplying 3 Aftercap. water, securely tighten the tank
Check to see that there is no water leak. Be sure to wipe off any excess water around the tank. When carrying the tank, hold it with both hands so that the tank opening is facing up.
4 Mount the tank to the main unit.
CAUTION
Insert the tank cap into the dented part of the unit. Make sure the tank is firmly attached by pushing it in until you hear a click.
Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result. Do not use hot water (of 40C or higher), chemical agents, aromatic substances, dirty water, etc. Deformation and/or malfunction may occur as a result. Do not use mineral water, ionized alkaline water, well water, purified water, etc. Propagation of mold fungus and bacteria may occur as a result. Securely tighten the tank cap. If the tank cap is difficult to tighten, loosen the cap one full turn to properly set the cap to the tank.
When the tank is dry and the water in the tray begins to dry up, the Water Supply Indicator Light will begin to flash. Fill the tank with water. When not operating in Humidify Mode, press the Humidify Mode Selection Button to turn the mode OFF; the Water Supply Indicator Light will turn off.
(Ex.) When water runs out during Automatic Humidify Mode
Flashing
OPERATION
Clean Air Mode Plasmacluster ON/OFF Indicator Light
Operation Indicator Mode Light Selection Button
Operation Indicator Light Mode Selection Button
Plasmacluster Indicator Light
ION SHOWER Indicator Light
Humidity Indicator Light
POWER ON/OFF BUTTON
Press the POWER ON/OFF Button on the main unit.
Mode activates after the short "beep". Unless unplug the power cord, the operation starts in the previous mode the unit was operated in. When stop operation during ION SHOWER Operation, the unit will back to the prior operation of ION SHOWER Operation. When the tank is dry, the Water Supply Indicator Light turns on. When not operating in Humidify Mode, turn the mode OFF by pressing the Humidify Mode Selection Button; the Water Supply Indicator Light will turn off.
Mode stops running after the long "beep".
ION SHOWER Mode Operation
Shower (Humidification + Plasmacluster Ion) Mode
When pushing the ION SHOWER Mode button, the ION SHOWER operation will be activated. (Direct start is available even when the unit is not turned on.) The concentrated Plasmacluster Ions (ION SHOWER) will be generated in the room like a shower for 15 minutes, repeating the airflow cycles between strong and gentle. (The Plasmacluster Indicator Light repeats its colour cycles between light and shade.), and effectively controls the airborne dust, pollen, mold, and allergen. When the operation finishes, the unit will return to the prior operation. When pushing the ION SHOWER button while the ION SHOWER operation mode is working, the unit will return to the prior operation.
The operation mode can be switched, and the Indicator Light will turn on.
Clean Air
During operation
Humidify
Humidify and Clean Air Mode
Use the Clean Air Mode and Humidify Mode together to quickly remove house dust floating in the air as well as eliminates odour. (for fresh air and those of saturated ones.) During Normal Use
Clean Air : Humidify : AUTO AUTO
4 sensors (a *Dust Sensor and an Odour Sensor for detecting impurities in the air, and Temperature/Humidity Sensors for detecting temperature and humidity) are used to automatically control airflow volume in accordance with the state of your room.
For Quiet Use at Bedtime, Etc. 2 sensors (a *Dust Sensor and an Odour Sensor for detecting Clean Air : AUTO impurities in the air) are used to automatically control airflow volume in accordance with the amount of impurities detected in Humidify : LOW your room, while humidifying gently and quietly in "Humidify LOW" Mode. When Air is Dry
Clean Air : Humidify : AUTO HIGH
2 sensors (a *Dust Sensor and an Odour Sensor for detecting impurities in the air) are used to automatically control airflow volume in accordance with the amount of impurities detected in your room, humidifying vigorously in "Humidify HIGH" Mode. (Operation noise increases)
* Only KC-6500E is equipped with the Dust sensor.
About Automatic Humidify Mode The Temperature/Humidity Sensors control humidity automatically in accordance with changes in room temperature.
on the size dryness of * Dependingin "Humidifyand suchMode. your room, humidity may not reach 55 - 65%. In cases, it is recommended to operate HIGH"
When operating Clean Air Mode and Humidify Mode together, Humidify Mode takes priority.
(when you wish to turn OFF Humidifying) On rainy days, etc. when your room is reasonably humid, turn Humidify Mode OFF.
Running Clean Air Mode Only
When the device is running, press the Humidify Mode Selection Button to turn Humidify Mode OFF. Press the Clean Air Mode Selection Button to set your preferred purification mode.
AUTO operation
The fan speed is automatically switched (HIGH*, MEDIUM, LOW) depending on the amount of impurities in the air. The sensors detect the impurities for efficient air purification. * HIGH fan speed is an intermediate speed between MEDIUM and MAX.
MAX operation
The unit will operate at a fan speed of MAX.
MEDIUM operation
The unit will operate at a fan speed of MEDIUM.
LOW operation
The unit will operate quietly using minimal air intake.
Plasmacluster Ion Mode
Each time the Button is pressed during operation, the Plasmacluster Ion Mode turns ON and OFF and the Plasmacluster ON/OFF Indicator Light turns ON (green) and OFF.
LIGHTS ON/OFF
Use when the Plasmacluster Indicator Light and the CLEANSIGN Light are too bright. (Please press the Plasmacluster ON/OFF Button for 3 seconds 2 short beeps are generated.) Switches the Plasmacluster Indicator Light and CLEAN-SIGN Light either ON or OFF.
When the Plasmacluster ON/OFF Button is released before the 2 short beeps, The Plasmacluster Ion Mode switches between ON and OFF; the CLEANSIGN Light does not turn ON/OFF because only the Plasmacluster Indicator Light turns ON/OFF.
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
Care Cycle 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
Care Cycle Every water supply
With a small amount of water inside and the tank cap closed, wash the tank set by shaking it. When using a kitchen detergent, dilute the detergent with water and rinse it thoroughly.
Tank Cap Tank
SENSORS (*DUST SENSOR, ODOUR SENSOR, TEMPERATURE/HUMIDITY SENSOR) Care Cycle 2 months * Only KC-6500E is equipped with the Dust sensor.
Remove dust from the surface of the hole of the sensors using a vacuum cleaner. KC-6500E
Opening of Odour Sensor Opening of Temperature/Humidity Sensor Opening of Dust Sensor
SENSOR FILTER CARE (KC-6500E only)
(The sensor Filter is in the sensor cover.) Detach the sensor filter and tap it lightly with your hand to remove the dust. If it is very dirty, wash it with water and then allow it to dry thoroughly.
Sensor Cover
Opening of Temperature/Humidity Sensor Opening of Odour Sensor Sensor Filter It does not have a front and a back.
FILTER CLEANING
Care Cycle 2 months
Clean the top surface of the Washable Active Carbon Filter lightly with a vacuum cleaner.
(The illustration has used KC-6500E )
WASHABLE ACTIVE CARBON FILTER CARE
HAND WASH ONLY! DO NOT TUMBLE DRY!
detergent and stir.
Dilute as indicated on the detergent container.
If the filter surface is very dirty, scrub with an old toothbrush.
The wet filter is heavy. Fix it securely for drying to make sure it does not fall down. The filter takes longer to dry in winter, on rainy days. Wash it on a day when the weather is good and dry it in the sun. Move it indoors at night to prevent freezing. Dry the filter outdoors in a well ventilated area. If dried indoors, the water dripping off the filter may soil your floor. Make sure that the activated carbon has not shifted to one side inside the filter. If it has, distribute it evenly with your fingers. Let the filter dry thoroughly. If used while the filter is still moist, then the air that is exhausted from the main unit will have an odour. It may take 1 or 2 days to dry.
Handle with care to prevent damage to the activated carbon particles.
3 Rinse thoroughly with clean water.
If rinsing in a container, be sure to rinse 3 to 4 times so that the odour is rinsed thoroughly from the filter.
4 Remove excess water.
The filter will be saturated with water after rinsing. To decrease drying time, wrap the filter in an old thick towel so that excess water can be removed.
Some carbon may adhere to the towel, but it is harmless. It is not allowed to wring out the filter.
6 Reinstalling the Filters.
Reinstall the filters as shown on Page E-10,11.
2 Allow the filter to soak approximately 10 minutes before washing.
container with 1 Fill a large a mild kitchen warm water, add
outdoors if pos5 Dry theinfilterwell ventilated sible a
MIST TRAY
The frequency of maintenance (descaling) will depend on the hardness of the water that you use; the harder the water the more often descaling will be necessary.
1 Remove the Tank and MIST Tray.
The Tank is removed first, and the tray is removed. Use both hands to pull out the MIST Tray to avoid spilling of water.
When Water Deposits are Difficult to Remove
Fill MIST tray with warm water, add a mild kitchen detergent and stir.
Dilute as indicated on the detergent container. Clean difficult-toreach parts with a cotton swab or tooth brush.
Remove the Tank and MIST Filter from the MIST Tray and drain the water by tilting the MIST Tray slowly.
MIST Filter
Rinse the MIST tray with water.
REPLACING THE FILTER
1. See page E-19 for directions on how to install the filters when replacing. 2. Fill in the usage start date of the filters on the Date Label. Disposal of Filter Please dispose of replaced filters according to the local disposal laws and regulations. MIST Filter materials: Rayon , Polyester
TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM
Odours and smoke are not removed. The CLEAN-SIGN Light illuminates green even when the air is impure. The CLEAN-SIGN Light illuminates orange or red even when the air is clean. A clicking or ticking sound is heard from the unit. The discharged air has an aroma or odour.
REMEDY (not a malfunction)
Clean or replace the filters if they appear to be heavily soiled. (Refer to E-17,E-20) The air could be impure at the time the unit was plugged in. (Refer to E-8) Pull out the plug from the electrical outlet, and insert the plug one minute later. The sensitivity of the sensors become unstable when the opening of the odour sensor or dust sensor is dirty or is clogged. Clean the dust around the sensor opening using a vacuum cleaner. (Refer to E-16) Clicking sound or ticking sound is emitted when the unit is generating ions.
The MIST Filter Indicator Light remains activated even after replacing filter. The Plasmacluster Indicator Light or the CLEAN-SIGN Light will not activate. Plasmacluster Indicator Light repeat colour cycles between light and shade. The Mist Filter Indicator Light does not turn on even water is in. When the water of the tank does not decrease or the decrease of the water is slow. The CLEAN-SIGN LIGHT switches frequently.
After replacing filters, connect the power cord to an outlet and press the Mist Filter Reset Button. (Refer to E-19) Check to see if the Lights OFF Mode selected. If so, then press the Plasmacluster ON/OFF Button for 3 seconds to activate the indicator lights. (Refer to E-15) The ION SHOWER operation is working. Please check if the impurities adhered to the surface of the Float. Clean the Mist Tray. Check to see if the Main Unit is put on a inclined surface. Check to see if the Mist Tray and Tank are installed correctly. Check the Mist Filter. Replace the filter when it is heavily soiled. (Refer to E-19,20) The CLEAN-SIGN Light will automatically switches the colours when detected by dust and odour sensors.
The unit does not operate when cigarette smoke is in the air.
Is the unit installed in a location that is difficult for the sensor to detect cigarette smoke? Are the dust or odour sensor openings blocked or clogged? (In this case, clean the openings.) (Refer to E-16) (Care Cycle : MIST Filter : 1 month)
Check to see if the filters are heavily soiled. Replace the filters. Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour. These ozone emissions are well below safety levels.
ERROR DISPLAY
LAMP INDICATION
The LOW Operation Indicator Light (Clean Air) blinks.
If error occurs again, contact the Sharp Service Centre.
REMEDY
Fan motor disconnected or abnormal. Operation stops. Pressing the POWER ON/OFF button will reset the error display. Microcomputer Errors. Remove the power plug, wait for a while, then reinsert the plug and try operating the device again. Temperature/Humidity Sensor Errors. Remove the power plug, wait for a while, then reinsert the plug and try operating the device again.
The Auto Operation Indicator Light (Clean Air ) blinks. The Humidity Indicator Light (30) blinks.
SPECIFICATIONS
The applicable floor surface area is appropriate for operating the unit of maximum fan speed. Applicable floor surface area indicates the space where a certain amount of dust particles can be removed in 30 minutes. (JEM1467) Humidification Amount changes in accordance with indoor and outdoor temperature and humidity. Humidification Amount increases as temperatures rise or humidity decreases. Humidification Amount decreases as temperatures decrease or humidity rises. Measurement Condition : 20 degree celcius, 30% humidity (JEM1426)
Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.8W of standby power. For energy conservation, unplug the power cord when the unit is not in use.
A. Information on Disposal for Users (private households) 1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.
If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements. By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you dont purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch.
B. Information on Disposal for Business Users.
1. In the European Union
If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
Free standing type Freistehende Ausfhrung
INHALT
WICHTIGE SICHERHEITSHINWEISE..D-2 WARNUNG... D-2 SICHERHEITSHINWEISE FR DEN BETRIEB.. D-3 RICHTLINIEN ZUR INSTALLATION.. D-3 RICHTLINIEN ZUM UMGANG MIT FILTERN. D-3 BITTE LESEN BEVOR SIE IHR NEUES LUFTREINIGUNGERT IN BETRIEB NEHMEN. D-4 LEISTUNGSMERKMALE... D-5 BEZEICHNUNGEN DER EINZELNEN KOMPONENTEN.. D-6 EXPLOSIONSZEICHNUNG.. D-6 RCKSEITE... D-7 IM LIEFERUMFANG... D-7 ANZEIGEN AM HAUPTGERT.. D-8
VORBEREITUNG... D-10 FITERINSTALLATION... D-10 WASSER EINFLLEN IN DEN TANK.. D-12 BETRIEB.... D-13 EIN-/AUSSCHALTER... D-13 IONENDUSCHE... D-13 AUSWAHLTASTE : MODUS.. D-14 LUFTBEFEUCHTUNG UND-REINIGUNG.. D-14 NUR LUFTREINIGUNG... D-15 PLASMACLUSTER-IONEN-MODUS.. D-15 LEUCHTEN EIN/AUS... D-15 PFLEGE UND WARTUNG.. D-16 HAUPTGERT... D-16 TANK... D-16 SENSOREN... D-17 FILTERREINIGUNG... D-17 PFLEGE DES AUSWASCHBAREN AKTIVKOHLEFILTERS. D-17 SPRHNEBELWANNE... D-18 SPRHNEBELFILTER... D-19 HINWEISE ZUM FILTERAUSTAUSCH.. D-20 STRUNGSBESEITIGUNG... D-21 TECHNISCHE DATEN.. D-22 ENTSORGUNSINFOMATIONEN.. D-23
KC-6400E KC-6500E
KC-6400E
KC-6500E
Free standing type Freistehende Ausfhrung
*Plasmacluster is a trademark of Sharp Corporation.
DEUTSCH
LUFTREINIGER BEDIENUNGSANLEITUNG
ENGLISH
AIR PURIFIER OPERATION MANUAL
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS.. E-2 WARNING... E-2 CAUTIONS CONCERNING OPERATION... E-3 INSTALLATION GUIDELINES... E-3 FILTER GUIDELINES... E-3 PLEASE READ BEFORE OPERATING YOUR NEW AIR PURIFIER. E-4 FEATURES... E-5
PART NAMES... E-6 ILLUSTRATIVE DIAGRAM... E-6 BACK... E-7 INCLUDED... E-7 MAIN UNIT DISPLAY.. E-8 PREPARATION.. E-10
ENGLISH DEUTSCH
FILTER INSTALLATION.. E-10 POUR WATER INTO THE TANK... E-12
OPERATION... E-13 POWER ON/OFF BUTTON.. E-13 ION SHOWER MODE OPERATION... E-13 MODE SELECTION BUTTON... E-14 HUMIDIFY AND CLEAN AIR MODE.. E-14 RUNNING CLEAN AIR MODE ONLY.. E-15 PLASMACLUSTER ION MODE.. E-15 LIGHTS ON/OFF... E-15 CARE AND MAINTENANCE... E-16 MAIN UNIT... E-16 TANK... E-16 SENSORS... E-16 FILTER CLEANING.. E-17 WASHABLE ACTIVE CARBON FILTER CARE. E-17 MIST TRAY... E-18 MIST FILTER... E-19
FILTER REPLACEMENT GUIDELINES... E-20
TROUBLE SHOOTING.. E-21 SPECIFICATIONS.. E-22 INFORMATION ON PROPER DISPOSAL.. E-23
Thank you for purchasing the SHARP Air Purifier. Please read this manual carefully for the correct usage information. Before using this product, be sure to read the section: Important Safety Instructions. After reading this manual, retain it in a convenient location for future reference.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
Read all instructions before using the unit. Use only a 220-240 volt outlet. Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet is loosened. Periodically remove dust from the power plug. Do not insert fingers or foreign objects into the intake or air outlet. When removing the power plug, always hold the plug and never pull the cord. Electrical shock and/or fire from short circuit may occur as a result. Do not remove the power plug when your hands are wet. Do not use this unit near gas appliances or fireplaces. When pouring the water into the Tank, when cleaning the unit and when not using the unit, be sure to unplug the power cord. Electrical shock from bad insulation and/or fire from short circuit may occur as a result. If the power cord is damaged, it must be replaced by the manufacturer, its service agent, Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard. Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a bathroom. Be cautious when cleaning the unit. Strong corrosive cleansers may damage the exterior. Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service Centre for any problems, adjustments, or repairs. When carrying the Main Unit, please remove the Tank and MIST Tray and hold the Handles on both sides. Do not drink in jest the water in the MIST Tray or Tank. It may cause illness. Change the Tank water every day with fresh tap water. Keep inside the Tank clean. (See Tank maintenance E-12) Leaving water in the Tank will result in mold, bacteria, and bad odours. In rare cases, this bacteria cause harmful physical effects. When not in use, dispose the water in the Tank and MIST Tray. Leaving water in the Tank and MIST Tray will cause mold and bacteria.
NOTE - Radio or TV Intreference
If this air purifier should cause interference to radio or television reception, try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation distance between the unit and radio/TV receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
CAUTIONS CONCERNING OPERATION
Do not block the intake and air outlet. Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into contact with steam. Do not lay the unit down when using. Always hold the handles on both sides of the unit when moving it. Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in bodily injury. Do not operate the unit without the filter. Do not wash and reuse HEPA filter. Not only does it not improve filter performance, it may cause electric shock or malfunction. Clean the exterior with a soft cloth only. The unit surface may be damaged or cracked. In addition, the sensors may malfunction as a result. The frequency of maintenance (descaling) will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary.
INSTALLATION GUIDELINES
During the operation of the product, please place the unit at least 2m away from equipments which involve electric wave such as televisions, radios or wave clocks, in case electrical interference occurs to such equipments. Avoid a location where the sensor is exposed to direct wind. The unit may not operate properly. Avoid locations where curtains, etc., come into contact with the intake or air outlet. Curtains, etc., may become dirty or a malfunction may occur. Avoid locations where the unit is exposed to condensation, due to drastic temperature changes. (Use under appropriate conditions between 5 and 35C in the room.) Place on a stable surface with sufficient air circulation. When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly. When placing the unit on an uneven surface, the water may leak from the Tank. Do not install when there is generation of lampblack, such as in a kitchen, etc. The unit surface may crack or the sensor may malfunction as a result. Leave about 60cm of space from the ceiling and wall. The wall behind the air outlet may become dirty as time passes. When using the unit for extended period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In addition, periodically clean the wall.
FILTER GUIDELINES
Follow the instructions in this manual for correct care and maintenance of the filters.
Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through a Washable Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection filter) inside of the unit, then discharges the air from its air outlet. The air purifier unit repeats this process by moving its internal fan. As air passes through, a new HEPA Filter can remove 99.97% of dust particles, of as small as 0.3 microns. The Washable Active Carbon Filter gradually absorbs odour elements as they repeatedly pass through the filter. (Odour elements are absorbed by HEPA Filter as well.) Some odour ingredients absorbed by the filters may become separated and may be discharged through the air outlet and result in additional odour. Depending on the usage environment, especially when the product is used in a condition significantly more severe than household use, this odour may become strong in a shorter period than expected. If the odour persists, then the filters are fully expended and it is necessary to purchase the optional replacement filter.
The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot completely remove the odour. (for example, odours from construction materials and pet odours). It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.
Washable Active Carbon Filter
(Common illustration has used KC-6500E)
FEATURES
New Air Purifier with "Humidifying" ability beyond the "Two-in-one" effect
"Synergy" of humidification and Plasmacluster ion realize the more powerful deodorization and eliminating of airborne dust, mold, or microbes. 1.Simultaneously generating the Plasmacluster ions and vaporized mist realize the longer life of ions and higher performance of purification. (Not available to get this effect from separate Humidifier and Air Purifier.) 2. Powerfully decompose and remove the airborne microbes or house dust. 3. Effectively eliminating of static electricity which tend to be caused in a dry environment. 4. Powerful deodorizing - not only the airborne odour but the adherent one which is inside of the fabric of clothes. 5. Provide the appropriate humidity in the room, and controls the activity of viruses in the dry room. 6. Usual air purifying operation is available by selecting humidify off mode.
Powerful Humidifying Ion Shower Operation
Enhanced Ion Shower operation with humidification releases concentrated Plasmacluster ions by repeating its airflow cycles between strong and gentle, effectively removes the airborne dust, pollen, mold, and allergen.
Dual Filtering System
1) Washable Active Carbon Filter Collect the large dust particles at the surface, and absorbes odour elements. Washable to maintain optimum deodorization performance. 2) HEPA (High Efficiency Particulate Air) Filter with Microbial control. High efficiency filter can remove the dust particles as small as 0.3 microns.
PART NAMES
ILLUSTRATIVE DIAGRAM
(KC-6400E)
Control Panel Air Outlet Temperature / Humidity Sensor Odour Sensor
HEPA Filter (white) Washable Active Carbon Filter (black) Main Unit
Front Panel
(KC-6500E)
Control Panel Air Outlet Odour Sensor Temperature / Humidity Sensor Dust Sensor Dust Sensor Filter HEPA Filter (white) Washable Active Carbon Filter (black) Filter Support Main Unit Front Panel
Handle
(2 locations left and right) (left and right/bottom side)
Air Inlet
Air Outlet
Tank Handle Date Label Tank
Tank Cap
Power Cord Power Plug
Float MIST Filter MIST Tray
(Shape of plug depends on country.)
(2 locations left and right)
(left and right/bottom side)
Tank Handle Tank
Date Label
Float MIST Filter
MIST Tray
INCLUDED
Operation manual
MAIN UNIT DISPLAY
Clean Air Mode
Mode Selection Button Plasmacluster ON/OFF Indicator Light (green) Operation Indicator Light(green)
ION SHOWER Mode Button
(Humidification + Plasmacluster)
Plasmacluster ON/OFF Button Plasmacluster Indicator Light
Colour Mode
Ion SHOWER Cycle of light and shade blue Plasmacluster ON Plasmacluster OFF Light off
CLEAN-SIGN Light
Air of room
red orange green
the colour of CLEAN-SIGN DETERMINING THE BASE IMPURITY RATE
ION SHOWER Indicator Light (blue.green)
Humidify Mode
Mode Selection Button
Operation Indicator Light(green)
MIST Filter Indicator Light (red)
Informs you when you must clean your MIST Filter. After cleaning
MIST Filter Reset Button
The Mist Filter Indicator Light turns off.
Water Supply Indicator Light (red)
Informs you when the tank needs to be refilled with water.
green)
Humidity Indicator Light (green)
Displays a rough measure of the current level of indoor humidity. (Inputting your preferred humidity settings is not allowed) The unit will check the current level of humidity for one minute immediately after the power is turned ON, during which time numbers 30 - 70 flash sequentially. (Ex.) At 50% humidity
Power ON/OFF Button
PREPARATION
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
To maintain the quality of the filters, they are installed in the main unit and packed in the plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
Install the filters
1 Remove the Front Panel.
Push in the hooks, then pull the Front Panel.
Front Panel Hook
HEPA 1 Place theunit. Filter within the main
Please make sure that the HEPA Filter is placed in proper orientation.
Do not install the filter backwards or the unit will not operate properly.
HEPA Filter
2 Remove the Filter Support.
Push in the hooks on top , then pull the Filter Support.
(Only KC-6500E)
2 Place the Washable Active Carbon Filter into the main
Filter Support
Remove the Washable Active Carbon Filter (black) and HEPA Filter (white) from the plastic bags.
HEPA Filter Wachable Active Carbon Filter
Fit the Washable Active Carbon Filter to the tab on the top of the main unit.
Fit the band to the tab facing toward you in the direction indicated by the arrow, and insert fully.
band(blue)
(At open) The filter may sometimes discharge deodorant powder, but such discharge does not affect deodorizing performance.
Band(blue)
Replace the Front Panel.
Place the Filter Support through the bands (2 places) located at the corners of the Washable Active Carbon Filter.
Wa s h a b l e A c t i v e Carbon Filter Front Panel Filter Support
Replace the Filter Support and the Washable Active Carbon Filter back to the main unit.
in 4 Fillthethe usage start date on Date Label.
Use the date as a guide for the Filter Replacement schedule.
Pour water into the Tank
This product can be used as an air purifier without putting water in the tank.
Tank Handle
Hold the tank handle and remove the tank.
2 Remove the tank cap and pour water.
Use drinkable tap water. (Generally speaking, tap water is sterilized with chlorine to suppress propagation of bacteria.) Change the tank water every day with fresh tap water.
supplying 3 Aftercap. water, securely tighten the tank
Check to see that there is no water leak. Be sure to wipe off any excess water around the tank. When carrying the tank, hold it with both hands so that the tank opening is facing up.
4 Mount the tank to the main unit.
CAUTION
Insert the tank cap into the dented part of the unit. Make sure the tank is firmly attached by pushing it in until you hear a click.
Do not expose the unit to water. Short circuit and/or electrical shock may occur as a result. Do not use hot water (of 40C or higher), chemical agents, aromatic substances, dirty water, etc. Deformation and/or malfunction may occur as a result. Do not use mineral water, ionized alkaline water, well water, purified water, etc. Propagation of mold fungus and bacteria may occur as a result. Securely tighten the tank cap. If the tank cap is difficult to tighten, loosen the cap one full turn to properly set the cap to the tank.
When the tank is dry and the water in the tray begins to dry up, the Water Supply Indicator Light will begin to flash. Fill the tank with water. When not operating in Humidify Mode, press the Humidify Mode Selection Button to turn the mode OFF; the Water Supply Indicator Light will turn off.
(Ex.) When water runs out during Automatic Humidify Mode
Flashing
OPERATION
Clean Air Mode Plasmacluster ON/OFF Indicator Light
Operation Indicator Mode Light Selection Button
Operation Indicator Light Mode Selection Button
Plasmacluster Indicator Light
ION SHOWER Indicator Light
Humidity Indicator Light
POWER ON/OFF BUTTON
Press the POWER ON/OFF Button on the main unit.
Mode activates after the short "beep". Unless unplug the power cord, the operation starts in the previous mode the unit was operated in. When stop operation during ION SHOWER Operation, the unit will back to the prior operation of ION SHOWER Operation. When the tank is dry, the Water Supply Indicator Light turns on. When not operating in Humidify Mode, turn the mode OFF by pressing the Humidify Mode Selection Button; the Water Supply Indicator Light will turn off.
Mode stops running after the long "beep".
ION SHOWER Mode Operation
Shower (Humidification + Plasmacluster Ion) Mode
When pushing the ION SHOWER Mode button, the ION SHOWER operation will be activated. (Direct start is available even when the unit is not turned on.) The concentrated Plasmacluster Ions (ION SHOWER) will be generated in the room like a shower for 15 minutes, repeating the airflow cycles between strong and gentle. (The Plasmacluster Indicator Light repeats its colour cycles between light and shade.), and effectively controls the airborne dust, pollen, mold, and allergen. When the operation finishes, the unit will return to the prior operation. When pushing the ION SHOWER button while the ION SHOWER operation mode is working, the unit will return to the prior operation.
The operation mode can be switched, and the Indicator Light will turn on.
Clean Air
During operation
Humidify
Humidify and Clean Air Mode
Use the Clean Air Mode and Humidify Mode together to quickly remove house dust floating in the air as well as eliminates odour. (for fresh air and those of saturated ones.) During Normal Use
LIGHTS ON/OFF
Use when the Plasmacluster Indicator Light and the CLEANSIGN Light are too bright. (Please press the Plasmacluster ON/OFF Button for 3 seconds 2 short beeps are generated.) Switches the Plasmacluster Indicator Light and CLEAN-SIGN Light either ON or OFF.
When the Plasmacluster ON/OFF Button is released before the 2 short beeps, The Plasmacluster Ion Mode switches between ON and OFF; the CLEANSIGN Light does not turn ON/OFF because only the Plasmacluster Indicator Light turns ON/OFF.
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the sensor and filters periodically. When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet hands. Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
Care Cycle 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
Care Cycle Every water supply
With a small amount of water inside and the tank cap closed, wash the tank set by shaking it. When using a kitchen detergent, dilute the detergent with water and rinse it thoroughly.
Tank Cap Tank
SENSORS (*DUST SENSOR, ODOUR SENSOR, TEMPERATURE/HUMIDITY SENSOR) Care Cycle 2 months * Only KC-6500E is equipped with the Dust sensor.
Remove dust from the surface of the hole of the sensors using a vacuum cleaner. KC-6500E
Opening of Odour Sensor Opening of Temperature/Humidity Sensor Opening of Dust Sensor
SENSOR FILTER CARE (KC-6500E only)
(The sensor Filter is in the sensor cover.) Detach the sensor filter and tap it lightly with your hand to remove the dust. If it is very dirty, wash it with water and then allow it to dry thoroughly.
Sensor Cover
Opening of Temperature/Humidity Sensor Opening of Odour Sensor Sensor Filter It does not have a front and a back.
FILTER CLEANING
Care Cycle 2 months
Rinse the MIST tray with water.
Change the water and repeat this procedure 2-3 times. Use clean water each time. Inadequate rinsing may cause the detergent odour or changes in the shape/ colour of the main unit.
Wash inside the tray with water to remove impurities. Float
Do not remove the float (Styrofoam). Clean difficult-toreach parts with a cotton-tipped swab or tooth brush.
Be sure that no gaps are left between the tray and the main unit when you load the tray. The unit may not operate if the tray is not securely fitted. Use only designated alkaline and acidic cleansers. Using non-designated cleansers can cause deformation, tarnishing, cracking (water leakage).
When Float comes off, please insert the tabs of the Float into the holes of Mist Tray as shown in the right diagram.
Insert the tab of the float into the hole.
Insert the float below this protrusion. Insert the tab on the other side of the float into the hole.
MIST FILTER
Care Cycle 1 month The MIST Filter Indicator Light turns on.
The frequency of maintenance (descaling) will depend on the hardness or the impurities of the water that you use; the harder the water the more often descaling will be necessary. MIST Filter Indicator Light The Mist Filter Indicator Light turns ON to remind you when it is time to clean the MIST Filter. The Indicator Light will turn ON after approximately 1 month of all-day, 24-hour use in Humidify Mode. Please clean the MIST Filter.
Remove the MIST Filter from the MIST Tray. Be careful of the water drops that may fall.
the 5 AttachTray. MIST Filter to the MIST
The MIST Filter does not need to be oriented in any particular position (forward/backward, up/ down) When not using the device for a prolonged period of time, be sure to dry the MIST Filter completely before installing.
Dissolve 3 teaspoons of citric acid and 600 ml of luke-warm water in a suitable container, and stir well.
<For using lemon juice>
Use only bottled 100% lemon juice with no pulp (please check before using and strain through a fine strainer there seems to be some pulp). Pour 50 ml of lemon juice and 600 ml of luke-warm water in a suitable container, and stir well.
Presoak the mist filter in the solution prior to cleaning.
When using lemon juice, it is recommended to presoak longer than citric acid.
Plug in the product and press the MIST Filter Reset Button on the main unit.
Rinse the MIST Filter with water.
Change the water and repeat this procedure 23 times. Use clean water each time. Inadequate rinsing may cause citric acid odour or changes in the shape/colour of the main unit. * Do not wash the MIST Filter vigorously. The Mist Filter might be damaged.
You will notice reddish-brown or white deposits forming on the surface of the MIST Filter. These impurities (calcium, etc.) are due to the impurities contained in tap water; this is not a defect. Replace the MIST Filter when it is covered completely in white deposits.
Citric acid, available at some drugstores, or 100% bottled lemon juice are used for descaling. Choose either one to use, and prepare the descaling solution. <For using citric acid>
2 Preparing the descaling solution.
FILTER REPLACEMENT GUIDELINES
The replacement period differs depending on the room environment, the usage hours and location of the unit. If dust or odours persists, replace the filters. (Refer to Please read before operating your new Air Purifier)
HEPA Filter / Washable Active Carbon Filter
Up to 5 years after opening
Guide for filter replacement timing Filter life can be greatly reduced in poor environments. The presence of cigarette smoke, pet dander and other concentrations of airborne particles will cause filters to become clogged in less time. Please check filters regularly and replace as needed.
Replacement Filters
Model FZ-6500SF (for KC-6500E) HEPA Filter : 1unit Washable Active Carbon Filter : 1unit Model FZ-6400SF (for KC-6400E) HEPA Filter : 1unit Washable Active Carbon Filter : 1unit
REPLACING THE FILTERS
1. See page E-10,11 for directions on how to install the filters when replacing. 2. Fill in the usage start date of the filters on the Date Label. Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations. HEPA Filter materials: Filter: Polypropylene Frame: Polyester Washable Active Carbon Filter Materials: Deodorizer: Activated charcoal Net: Polypropylene 60%, Polyester 40%
Up to 1 year after opening
Guide for filter replacement timing.
The Mist Filter life can be greatly reduced in poor environments. Please exchange the Mist Filter, even if within 1 year after opening, if the following conditions appear: Mineral deposits (white, black, or red masses) do not come off after cleaning or the Mist Filter is still dirty. Severe damage or change of shape has resulted.
Replacement Filter
Model FZ-6500MF (for KC-6500E) MIST Filter : 1unit Model FZ-6400MF (for KC-6400E) MIST Filter : 1unit
REPLACING THE FILTER
1. See page E-19 for directions on how to install the filters when replacing. 2. Fill in the usage start date of the filters on the Date Label. Disposal of Filter Please dispose of replaced filters according to the local disposal laws and regulations. MIST Filter materials: Rayon , Polyester
TROUBLESHOOTING
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM
Odours and smoke are not removed. The CLEAN-SIGN Light illuminates green even when the air is impure. The CLEAN-SIGN Light illuminates orange or red even when the air is clean. A clicking or ticking sound is heard from the unit. The discharged air has an aroma or odour.
REMEDY (not a malfunction)
Clean or replace the filters if they appear to be heavily soiled. (Refer to E-17,E-20) The air could be impure at the time the unit was plugged in. (Refer to E-8) Pull out the plug from the electrical outlet, and insert the plug one minute later. The sensitivity of the sensors become unstable when the opening of the odour sensor or dust sensor is dirty or is clogged. Clean the dust around the sensor opening using a vacuum cleaner. (Refer to E-16) Clicking sound or ticking sound is emitted when the unit is generating ions.
The MIST Filter Indicator Light remains activated even after replacing filter. The Plasmacluster Indicator Light or the CLEAN-SIGN Light will not activate. Plasmacluster Indicator Light repeat colour cycles between light and shade. The Mist Filter Indicator Light does not turn on even water is in. When the water of the tank does not decrease or the decrease of the water is slow. The CLEAN-SIGN LIGHT switches frequently.
After replacing filters, connect the power cord to an outlet and press the Mist Filter Reset Button. (Refer to E-19) Check to see if the Lights OFF Mode selected. If so, then press the Plasmacluster ON/OFF Button for 3 seconds to activate the indicator lights. (Refer to E-15) The ION SHOWER operation is working. Please check if the impurities adhered to the surface of the Float. Clean the Mist Tray. Check to see if the Main Unit is put on a inclined surface. Check to see if the Mist Tray and Tank are installed correctly. Check the Mist Filter. Replace the filter when it is heavily soiled. (Refer to E-19,20) The CLEAN-SIGN Light will automatically switches the colours when detected by dust and odour sensors.
The unit does not operate when cigarette smoke is in the air.
Is the unit installed in a location that is difficult for the sensor to detect cigarette smoke? Are the dust or odour sensor openings blocked or clogged? (In this case, clean the openings.) (Refer to E-16) (Care Cycle : MIST Filter : 1 month)
Check to see if the filters are heavily soiled. Replace the filters. Plasmacluster Air Purifiers emit small traces of ozone which may produce an odour. These ozone emissions are well below safety levels.
ERROR DISPLAY
LAMP INDICATION
The LOW Operation Indicator Light (Clean Air) blinks.
If error occurs again, contact the Sharp Service Centre.
REMEDY
Fan motor disconnected or abnormal. Operation stops. Pressing the POWER ON/OFF button will reset the error display. Microcomputer Errors. Remove the power plug, wait for a while, then reinsert the plug and try operating the device again. Temperature/Humidity Sensor Errors. Remove the power plug, wait for a while, then reinsert the plug and try operating the device again.
The Auto Operation Indicator Light (Clean Air ) blinks. The Humidity Indicator Light (30) blinks.
SPECIFICATIONS
The applicable floor surface area is appropriate for operating the unit of maximum fan speed. Applicable floor surface area indicates the space where a certain amount of dust particles can be removed in 30 minutes. (JEM1467) Humidification Amount changes in accordance with indoor and outdoor temperature and humidity. Humidification Amount increases as temperatures rise or humidity decreases. Humidification Amount decreases as temperatures decrease or humidity rises. Measurement Condition : 20 degree celcius, 30% humidity (JEM1426)
Standby Power In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product consumes about 0.8W of standby power. For energy conservation, unplug the power cord when the unit is not in use.
A. Information on Disposal for Users (private households) 1. In the European Union
Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one.
*) Please contact your local authority for further details.
Attention: Your product is marked with this symbol. It means that used electrical and electronic products should not be mixed with general household waste. There is a separate collection system for these products.
If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements. By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.
2. In other Countries outside the EU
If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you dont purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch.
B. Information on Disposal for Business Users.
1. In the European Union
If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.
INHALT
WICHTIGE SICHERHEITSHINWEISE..D-2 WARNUNG... D-2 SICHERHEITSHINWEISE FR DEN BETRIEB.. D-3 RICHTLINIEN ZUR INSTALLATION.. D-3 RICHTLINIEN ZUM UMGANG MIT FILTERN. D-3 BITTE LESEN BEVOR SIE IHR NEUES LUFTREINIGUNGERT IN BETRIEB NEHMEN. D-4 LEISTUNGSMERKMALE... D-5 BEZEICHNUNGEN DER EINZELNEN KOMPONENTEN.. D-6 EXPLOSIONSZEICHNUNG.. D-6 RCKSEITE... D-7 IM LIEFERUMFANG... D-7 ANZEIGEN AM HAUPTGERT.. D-8
VORBEREITUNG... D-10 FITERINSTALLATION... D-10 WASSER EINFLLEN IN DEN TANK.. D-12 BETRIEB.... D-13 EIN-/AUSSCHALTER... D-13 IONENDUSCHE... D-13 AUSWAHLTASTE : MODUS.. D-14 LUFTBEFEUCHTUNG UND-REINIGUNG.. D-14 NUR LUFTREINIGUNG... D-15 PLASMACLUSTER-IONEN-MODUS.. D-15 LEUCHTEN EIN/AUS... D-15 PFLEGE UND WARTUNG.. D-16 HAUPTGERT... D-16 TANK... D-16 SENSOREN... D-17 FILTERREINIGUNG... D-17 PFLEGE DES AUSWASCHBAREN AKTIVKOHLEFILTERS. D-17 SPRHNEBELWANNE... D-18 SPRHNEBELFILTER... D-19 HINWEISE ZUM FILTERAUSTAUSCH.. D-20 STRUNGSBESEITIGUNG... D-21 TECHNISCHE DATEN.. D-22 ENTSORGUNSINFOMATIONEN.. D-23
Tags
50 4T R2 0 Singer 155 Plcxp56 Motorola V3 FA130 Sega Wccf Triax C10 Deskjet 692K XM1800S M1003R DC C800 SF-7800 7850 AG-HMC151E Sbcmc8650 PDP-4270XD DKS-6100B RB67pros MAC 5-18 Dect180 YP-T7FZS CDX-GT240 MD 5275 Valloire 2 VFX-SD SPV M600 600 E HT-C655W ALL-IN-ONE YZ426F-2000 FXO-08 Chrono VD53 Remote DIR-652 TSG 604 AS Gr16 Prostar 190 MWD7006 DCP-310CN 10 GO 9-5 2002 KAC-PS500F GT-B7320L Piranhamax 15 Scanner Rtgr328N CLP-310 Easyshare CD33 3 1 1 2 XV-Z9000E DSX6073 03A DEQ224 DSC-H9 DCR-HC28E HQ5705 LV800 DV6500 KDC-M907 DVS-9513N RA-971 Cutter TX-550 MS9007C 6592G KD-AVX77E MC18AHR PS50C96HD 42PFL9900D KDL-55NX810 18-270 VC DW621 Madden 2005 EW952S Series Multipass F30 Kfea100 KDL-52V5500 MT370 MT600 KDL-40W4500 CDX-CA700 Mountaineer 2002 RD-HA3 Review LG V271 25415 LE19R71W V7 30 VLT4105 TX-SR500E Solo 2500 DCR-TRV33K Yzea 600 DCR-TRV310E P-661HW-D Tester DR-EX300IP DCS-3430 SGH-L760V EP738
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101
