SITRANS T measuring instruments for temperature
SITRANS T transmitters for mounting in sensor head
SITRANS TK/TK-H Two-wire system
Overview
The signal supplied by a resistance-based sensor (two, three or four-wire circuit) or a thermocouple element is amplified in the input stage. The voltage proportional to the input variable is then converted into digital signals in the analog/digital converter (1). These signals are forwarded electrically isolated (2) to the microprocessor (3). They are converted there in accordance with the sensor characteristic and further parameters (damping, ambient temperature etc.). The signal prepared in this way is converted in the digital/analog converter (4) into a load-independent direct current (4 to 20 mA). The power supply (5) is located in the output signal circuit. The SITRANS TK-H transmitter is parameterized and operated using a PC (6) connected to the two-wire line via the interface module for SIPROM software (HART modem, 7). A hand-held communicator can also be used for this purpose. The signals needed for communication in conformity with the HART r protocol V 5.7 are superimposed on the output current in accordance with the frequency shift keying (Frequency Shift Keying, FSK) method.
The smart solution The transmitter with the same capabilities as a SITRANS TK and a standardized HART interface. This universal transmitter integrates your temperature measurement in the TIA concept (Totally Integrated Automation). This makes central engineering possible, bringing you time and cost benefits. SIMATIC PDM or another HART programming tool can be used for the configuration. The transmitter provides electrical isolation and enables the connection of resistance thermometers, resistance-based sensors, thermocouples and voltage-based sensors.
Technical specifications
Input Resistance thermometer Measured variable Sensor type Acc. to DIN IEC 751 Acc. to JIS C 1604 Acc. to DIN IEC 751 Voltage measurement Type of connection Resistance-based sensors Measured variable Measuring range limits Voltage measurement Type of connection Thermocouple elements Measured variable Sensor type Acc. to DIN IEC 584-1 Acc. to DIN Acc. to DIN 4937 Acc. to ASTM 988 Voltage measurement Cold junction compensation mV Sensor Measured variable Measuring range limits Voltage measurement Overload capacity of the input Input resistance Output DC voltage 1100 mV Voltage-linear or programmable -0.5. +35 V DC 1 M 4 to 20 mA, 2-wire Acc. to HART V 5.x See "Digital measuring errors" < 0.1% of span < 0.5 K (0.9 F) 0.01%/C (0.0056%/F), typ. 0.003%/C (0.0016%/F) < 0.005% of span/V < 0.03% in first month Temperature Type B, E, J, K, R, S, T Type L, U Type N Type C, D Temperature-linear Internal, external with Pt100 or external with a fixed value Ohmic impedance 2200 Resistance-linear or programmable (TK) Two, three or four-wire system Temperature Pt25. Pt1000 Pt25. Pt1000 Ni25. Ni1000 Cu25. Cu1000 Temperature-linear Two, three or four-wire system
Application
SITRANS TK/TK-H temperature transmitters with "Non incendive" type protection can be mounted within potentially explosive atmospheres (zone 2). SITRANS TK/TK-H temperature transmitters with "Flame-proof enclosure" type protection can be mounted within potentially explosive atmospheres (zone 1).
Function
The SITRANS TK/TK-H temperature transmitter converts the signals from resistance thermometers, resistance-based sensors, thermocouples or voltage sensors into a load-independent direct current corresponding to the sensor characteristic. As a result of its compact design, the transmitter fits in the sensor head type B (DIN 43 729). The communication capability via the HART protocol V 5.x of the SITRANS TK-H permits parameterization using a PC or HART communicator (hand-held communicator). Parameterization is carried out using a PC for the programmable SITRANS TK-L. Mode of operation
Sensor TC RTD A D SITRANS TK-H 3 mP D 4 A 7 Analog-to-digital converter Electrical isolation Microprocessor Digital-to-analog converter Power supply PC/laptop HART modem Power supply 5 Load HART modem
Output signal Communication for SITRANS TK-H Measuring accuracy Digital measuring errors Error in the analog output Error in the internal cold junction Temperature drift Influence of the power supply on the span and zero point Long-term drift
Siemens FI 01 2006
Technical specifications (continued)
Rated conditions Ambient conditions Ambient temperature Relative humidity Electromagnetic compatibility Interference immunity Emitted interference Design Weight Dimensions Material Power supply For SITRANS TK For SITRANS TK-H Electrical isolation Test voltage Insulation Certificate and approvals Explosion protection ATEX "Intrinsic. safe" type of protection - EC-Type Examination Certificate for TK and TK-H Ex tested for zone 2n - Conformity statement Explosion protection to FM Identification (IS, I, NI) II 1 G EEx ia IIC T5/T6 DEMKO 03 ATEX 134603X 6.5. 35 V DC (30 V for EEx ia) 8. 35 V DC (30 V for EEx ia) Between input and output U eff = 3.75 kV, 50 Hz, 1 min 500 V AC 50 g (0.11 lb) see "Dimension drawings" Moulded plastic Acc. to EN Acc. to EN 50 081-2 -40. +85 C (-40. 185 F) < 98%, with condensation
Digital measuring errors Resistance thermometer
Input Measured range Min. measured span C (F) C (F) -200. + (18) (-328. +1562) -200. + (18) (-328. +662) -50. + (18) (-58. +482) -50. + (18) (-58. +392) Digital accuracy C (F) 0.1 (0.18) 0.1 (0.18) 0.1 (0.18) 0.1 (0.18)
Pt25. Pt500 Pt501. Pt1000 IEC Ni 25. Ni1000 Cu25. Cu1000
Resistance-based sensors
Input Measured range Resistance Resistance 0. 390 0. 2200 Min. measured span Digital accuracy 0.05 0.25
Thermocouple elements
Input Measured range C (F) +500. +1820 (+932. +3308) 0. +2300 (+32. +4172) 0. +2300 (+32. +4172) -250. +900 (-418. +1652) -210. +1200 (-346. +2192) -230. +1370 (-382. +2498) -200. +900 (-328. +1652) -200. +1300 (-328. +2372) 0. +1750 (+32. +3182) 0. +1750 (+32. +3182) -220. +400 (-364. +752) -200. +600 (-328. +1112) Min. measured span C (F) 50 (90) 100 (180) 100 (180) 50 (90) 50 (90) 50 (90) 50 (90) 50 (90) 100 (180) 100 (180) 40 (7.2) 50 (90) Digital accuracy C (F) 2 (3.6) 2 (3.6) 2 (3.6) 1 (1.8) 1 (1.8) 1 (1.8) 1 (1.8) 1 (1.8) 2 (3.6) 2 (3.6) 1 (1.8) 1 (1.8)
Type B II 3 G EEx nA IIC T5/T6 DEMKO 03 ATEX 134604X Certificate of Compliance 3017742 IS / I / 1 / ABCDEFG / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F) I / 0 / AEx ia / IIC / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F) NI / I / 2 / ABCD / T5 Ta = 85 C (185 F), T6 Ta = 50 C (112 F) nach control drawing A5E00226012B U i = 30 V, Ii = 100 mA, Pi = 0,75 W, Ci =5 nF, Li = 15 H Type C Type D Type E Type J Type K Type L Type N Type R Type S Type T Type U CPU of type 486 upwards, compatible with industrial standard 3.5" diskette drive Hard disk with 5 MB vacant space min. 4 MB RAM VGA graphics adapter (or compatible) with at least 16 colors One vacant serial port Mouse or compatible pointing device and printer (recommended) MS-DOS V 5.0 upwards, MS-Windows V 3.1 upwards see Chapter 9
Entity parameters
Hardware and software requirements for the parameterization software SIPROM TK for SITRANS TK Personal computer
mV Sensor
Input Measured range mV mV Sensor mV Sensor -10. +70 -100. +1100 Min. measured span mV Digital accuracy V 40 400
PC operating system SIMATIC PDM for SITRANS TK-H
Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: 0. 100 C (32. 212 F) Output with sensor breakage: 23 mA
Selection and ordering data Order No.
Mounting on DIN rail
Temperature transmitter SITRANS TK for installation in sensor head type B (DIN 43729); two-wire system 4. 20 mA; with electrical isolation without explosion protection } 7NG3120-1JN01 with explosion protection Ex n for zone 2 } 7NG3121-1JN01 with explosion protection ATEX (EEx ia) and } 7NG3122-1JN01 FM (IS, I, NI) Temperature transmitter SITRANS TK-H for installation in sensor head type B (DIN 43729); two-wire system 4. 20 mA; capable of communication according to HART V 5.x with electrical isolation without explosion protection } 7NG3120-2JN01 with explosion protection Ex n for zone 2 } 7NG3121-2JN01 with explosion protection ATEX (EEx ia) and } 7NG3122-2JN01 FM (IS, I, NI) Further designs Please add "-Z" to Order No. and specify Order code(s) and plain text. Customer-specific setting of operating data Test protocol (5 measuring points) Accessories SIPROM TK parameterization software for SITRANS TK, German/English/French Modem for SITRANS TK Order code
Mounting of transmitter on DIN rail, schematic diagram
14 (0.55) 50,5 (1.99) 33 (1.30)
Y01 C11 Order No. } 7NG3190-8KB } 7NG3190-6KB
59,6 (2.35)
Instruction Manual for SITRANS TK/TK-H } A5E00226012 German/English (not included in delivery of the device) DIN rail adaptor } 7NG3092-8KA for head mounted transmitters (set of 5 pcs.) SIMATIC PDM parameterization software also for SITRANS TK-H HART modem with RS232 interface with USB interface } 7MF4997-1DA
DIN rail adaptor, dimensions in mm (inch)
see Chapter 9
Schematics
} 7MF4997-1DB
} Available ex stock. D) Subject to export regulations AL:N, ECCN: EAR99H. Power supply units see "SITRANS I supply units and input isolators".
Dimensional drawings
44 (1.73)
1, 2 UH, IA 3. 6 Sensor
Pin assignment
33 (1.30)
SITRANS TK/TK-H, dimensions in mm (inches) Siemens FI 01 2006
24 (0.95)
Potentiometer Resistance Current measurment
No compensation1)
Voltage measurement
R Dreileiter-Kompensation fr bertragungswiderstand 2)
Three-wire line compensation
Four-wire compensation for line and transfer resistance 2)
Four-wire line compensation
Resistance thermometer
Thermocouple
1 No line compensation )
Internal cold junction compensation (CJC)
External CJC-compensation 1 No line compensation ) Note: Line resistance (per wire in the case of three- and four-wire connections) T > 600 C (> 1112 F): max. 10 W T < 600 C (> 1112 F): max. 30 W ) Line resistance for compensation is programmable. 2 ) Resistance between start of resistance and sliding contact.
RTD RTD
Sensor connection assignment
External CJC-compensation Three-wire line compensation

SITRANS T measuring instruments for temperature
SITRANS T transmitters for mounting in sensor head
SITRANS TK-L Two-wire system (Pt100)
Overview
accordance with the sensor characteristic and further parameters (damping, ambient temperature etc.). The signal prepared in this way is converted in the digital/analog converter (3) into a load-independent direct current of 4 to 20 mA. The power supply (4) is located in the output signal circuit.
Technical specifications
Input Resistance thermometer Measured variable Sensor type Voltage measurement Type of connection Resolution Measuring accuracy Span < 250 C (450F) Span > 250 C (450F) < 0.25 C (0.45 F) < 0.1% of span < 0.1 C (0.18 F) 0.3 mA < 0.7 s -200. 850 C (-328. +1562 F) > 25 C (45 F) C or F Programmable, max. 10 C (18 F) Max. 20 /line DC 35 V 50 and 60 Hz 4. 20 mA, 2-wire DC 8 to 35 V (28 V with Ex) 3.5/23 mA (programmable) 0. 30 s Against reversed polarity 12 bit < 0.1% of span < 0.01% of span/V typ. 0.003%/C (0.0016%/F) max. 0.01%/C (0.0056%/F) Temperature Pt100 (DIN IEC 751) Temperature-linear Two, three or four-wire system 14 bit
The economical transmitter for Pt100 measurements The SITRANS TK-L dispenses with electrical isolation and universal sensor connection to provide a low-cost alternative for Pt100 measurements. SIPROM TK software is used in combination with the modem for SITRANS TK for the parameterization. A very compact design makes the SITRANS TK-L ideal for the retrofitting of measuring points or for the use of analog transmitters. The transmitter is available as a non-Ex version as well as for use in potentially explosive atmospheres.
Repeatability Measuring current Measuring cycle Measured range Measured span Unit Offset Line resistance Overload capability Noise rejection Output Output signal Power supply Underrange/overrange limits Filter time Protection Resolution Accuracy Power supply effect Temperature drift Rated conditions Ambient conditions Ambient temperature Relative humidity Electromagnetic compatibility Interference immunity
Application
SITRANS TK-L temperature transmitters with "Non incendive" type protection can be mounted within potentially explosive atmospheres (zone 2). SITRANS TK-L temperature transmitters with "Flame-proof enclosure" type protection can be mounted within potentially explosive atmospheres (zone 1).
Function
The SITRANS TK-L transmitter converts the signals from Pt100 resistance thermometers into a load-independent direct current corresponding to the sensor characteristic. As a result of its compact design, the transmitter fits in the sensor head type B (DIN 43729). Parameterization is carried out using a PC for the programmable SITRANS TK-L. Mode of operation
Power supply 3 D A 4 Load
-40. +85 C (-40. +185 F) < 98%, with condensation According to EN 50082-2 According to EN 50081-g (0.11 lb) see "Dimension drawings" Moulded plastic IP40 IP00
Sensors Pt100 A
SITRANS TK-L 1 D 2 mP
Emitted interference Design Weight Dimensions Material Degree of protection
Analog-to-digital converter Microprocessor Digital-to-analog converter Power source
Housing Terminals Certificate and approvals Explosion protection ATEX "Intrinsic. safe" type of protection - EC-Type Examination Certificate "Non incendive" type of protection - EC-Type Examination Certificate
The signal supplied by a Pt100 (two, three or four-wire circuit) is amplified in the input stage. The voltage proportional to the input variable is then converted into digital signals in the analog/digital converter (1). They are converted in the microprocessor (2) in
ATEX II 1 G EEx ia IIC T4 DEMKO 01 ATEX 129483 X ATEX II 3G EEx nA IIC T4 DEMKO 01 ATEX 129482 X
Siemens FI 01 2006
Technical specifications (continued)
Hardware and software requirements for the parameterization software SIPROM TK for SITRANS TK and TK-L Personal computer CPU of type 486 upwards, compatible with industrial standard 3.5" diskette drive Hard disk with 5 MB vacant space min. 4 MB RAM VGA graphics adapter (or compatible) with at least 16 colors One vacant serial port Mouse or compatible pointing device and printer (recommended) MS-DOS V 5.0 upwards, MS-Windows V 3.1 upwards
Dimensional drawings
44 (1.73)
33 (1.30) 19 (0.75)
PC operating system
Factory setting: Pt100 (IEC 751) with three-wire circuit Measuring range: 0. 100 C (32 . 212 F) Output with sensor breakage: 23 mA
Selection and ordering data Temperature transmitter SITRANS TK-L for Pt100 for installation in sensor head type B (DIN 43729); two-wire system 4. 20 mA; programmable without explosion protection } 7NG3120-0JN00 with explosion protection EEx ia for zone 1 } 7NG3122-0JN00 and Ex n for zone 2 Further designs Please add "-Z" to Order No. and specify Order code(s) and plain text. Customer-specific setting of operating data Test protocol (5 measuring points) } Available ex stock. Accessories SIPROM TK parameterization software for SITRANS TK and TK-L German/English/French Modem for SITRANS TK and TK-L Instruction manual for SITRANS TK-L German/English (not included in delivery of the device) Order No. } 7NG3190-8KB Order code Order No.
SITRANS TK-L, dimensions in mm (inches)
Mounting on DIN rail
Y01 C11
Mounting of transmitter on DIN rail, schematic diagram
14 (0.55) 50,5 (1.99) 33 (1.30)
} A5E00095604
DIN rail adaptor } 7NG3092-8KA for head mouted transmitters (set of 5 pcs.) } Available ex stock. Power supply units see "SITRANS I supply units and input isolators".
DIN rail adaptor, dimensions in mm (inch)
59,6 (2.35)
} 7NG3190-6KB
Schematics
1, 2 UH, IA 3. 6 Sensors (Pt100)
Pin assignment
Resistance thermometer
No line compensation 1)
Three-wire line compensation
Four-wire line compensation
) Line resistance for compensation is programmable.
Sensor connection assignment
Tags
Aqsf 129 LW15M13C Fostex 4050 Micra DJ-175 T AV-R700 E1720NRX 600SE Omnibot 2000 Powershot S60 DR-MV7su-dr-mv7 Multitap Multi VGN-FS115M Dimension E510 HDR-XR550V Motor 15DE Dvdr3440H 58 Vert TR 42LG50D 1 DVD RX-V661 Compact Plus DVP-NS328 ROC 4407 HDC-SD9 MA-1350 2 Chorus Avent Coolpix L1 Macbook PRO 57114 950IS 1 2 BW410 Family 28PW8807 Cs3 Sun-firestorm II ASC Elna CE20 VGN-NR21s S HT488 SA7 V101 NV-MS4B Kenwood A998 P5P800S HD7600 Syncmaster 732N SU-WL31 TME-M580 Temporis 09 Sacred-mapa 933NW SX-KN2400 XE-A404 20HF5234 TDM900-2008 CDX-393mkii GT-M8910 14GR1221 Review 2 Plus VCR-3030 37LG5500 Photosmart M627 CLX-3185FW CY-RC50KN KD-G201 CMT-BX20I SP101 PPC-6700 Milan CDX-3000 PM0 4 Abit BL7 Asus W3 Pioneer A-C5 XD221U-ST MWG 729 Classroom HV-DH10 Nikon D2XS Z8245 SB-246 460UX-2 PT-AE2000 DMC-FZ8 Graphics Card DPF-X1000N Gt TH-42PW5 KX-FL613FX DC-600UW AWO 9863 Pleo Pleo Traffic PRO CX6200 View 5 CQ-FX321N KH 203
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding