doc0

Version DT 3LDPU (UNIT, SET, M) Price per PU PS*/ P. unit PG Weight per PU approx. kg 1 unit 1 unit 0.079 0.072
4. contact (N conductor) Leading switch-on, lagging switch-off N or PE terminals Through-type 3LD9 250-0BA (left) 3LD9 250-2BA (right) Auxiliary switches For mounting on the left and/or right, lagging switch-on, leading switch-off } 3LD9 250-2BA } 3LD9 250-0BA
1 NO + 1 NC For mounting on the left and/or right, lagging switch-on, leading switch-off, with gold-plate contacts for SIMATIC request 1 NO + 1 NC
4. contact (N conductor) Leading switch-on, lagging switch-off N or PE terminals Through-type 3LD9 250-0CA (left) 3LD9 250-2CA (right) Auxiliary switches For mounting on the left and/or right, lagging switch-on, leading switch-off 1 NO + 1 NC 2 NO For mounting on the left and/or right, lagging switch-on, leading switch-off, with gold-plate contacts for SIMATIC request 1 NO + 1 NC } 3LD9 250-2CA unit 103 0.073 } 3LD9 250-0CA unit 103 0.080
Rotary operating mechanisms Lockable in 0 position with up to 3 padlocks For four-hole mounting, including seal - Black 3LD9 284-1B - Red/Yellow For center-hole mounting, including seal and nut - Black - Red/Yellow A A 3LD9 284-1D 3LD9 284-3D 1 unit 1 unit 0.155 0.155 A A 3LD9 284-1B 3LD9 284-3B 1 unit 1 unit 0.154 0.152
3LD9 284-3D Assembly tools For center-hole mounting with nut A 3LD9 256-0A units 103 0.027
3LD9 256-0A Switching shafts 6 x 6 mm Length 300 mm Length 600 mm Inscription labels With English/German inscription (MAIN SWITCH/HAUPTSCHALTER) 3LD9 286-1A Without inscription Terminal covers as additional touch protection (also for distribution board mounting) Can be snapped on at top and bottom 3LD9 251-2A (left) 3LD9 251-0A (right) 1-pole 3-pole A A 3LD9 251-2A 3LD9 251-0A 4 units 4 units 0.100 0.009 A A 3LD9 286-1A 3LD9 286-4A units units 0.005 0.054 C C 3LD9 205-0C 3LD9 205-2C 5 units 5 units 0.476 0.476

kg 0.101 0.092

4. contact (N conductor) Leading switch-on, lagging switch-off N or PE terminals Through-type 3LD9 280-0B (left) 3LD9 280-2B (right) Auxiliary switches For mounting on the left and/or right, lagging switch-on, leading switch-off 1 NO + 1 NC 3LD9 200-5B For mounting on the left and/or right, lagging switch-on, leading switch-off, with gold-plate contacts for SIMATIC request 1 NO + 1 NC C 3LD9 200-5BF unit 103 0.028 } 3LD9 200-5B unit 103 0.046 } 3LD9 280-2B } 3LD9 280-0B

8UC74 24-3BB44

Further accessories
Terminal covers (1 set = 6 units) } 3KX3 557-3DA1 unit 103 0.277
3KX3 557-3DA01 Door-coupling rotary operating mechanisms IP65 Black handle, shaft 300 mm EMERGENCY-STOP (yellow/red), square shaft 300 mm Extension shaft 300 mm long Extension shaft 600 mm long Auxiliary switches with switching cam 1 NO + 1 NC (complete mounting kit)

C B B B B

8UC73 14-1BB44 8UC73 24-3BB44 8UC8UC3KX2 231-1A
1 unit 1 unit 1 unit 1 unit 1 unit
0.200 0.200 0.315 0.640 0.049
3KX2 231-1A Grounding brackets Arc chute (spare part with 3 arc-splitter assemblies) Arcing contacts (spare part with 3 fixed and 3 movable contacts) B B B 3KX2 252-1A 3KY2 202-0B 3KY2 204-0A unit 1 unit 1 unit 103 0.049 0.640 0.202

3KY2 204-0A

3KE44/3KE45 Changeover switches
Changeover switches with interruption Switch I ON Switch II OFF Switch I OFF Switch II OFF Switch I ON Switch II ON 3KX2 210-0D B 3KX2 210-0D unit 103 2.442
Door-coupling rotary operating C mechanisms IP65 Handle (black) for changeover switches with interruption, shaft 300 mm Direct operating mechanisms Twin handle (black) for fixed mounting B

8UC74 14-1BF44

Changeover switches without interruption Switch I ON Switch II OFF B Switch I ON Switch II ON Switch I ON Switch II ON Door-coupling rotary operating mechanisms IP65 Handle (black) for changeover switches without interruption, shaft 300 mm Direct operating mechanisms Twin handle (black) for fixed mounting C

8UC74 14-1FG44

Terminal covers (top and bottom) Door-coupling rotary operating mechanisms IP65 Black handle, shaft 300 mm EMERGENCY-STOP (yellow/red), square shaft 300 mm Extension shaft 300 mm long Extension shaft 600 mm long 3KX2 231-1A Auxiliary switches 1 NO + 1 NC (complete mounting kit) Grounding brackets Arc chute (spare part with 3 arc-splitter assemblies) Arcing contacts Spare part with 3 fixed and 3 movable contacts B 3KX2 252-0C unit 103 0.424

C B B B B B B B

8UC73 14-1BB44 8UC73 24-3BB44 8UC8UC3KX2 231-1A 3KX2 252-1A 3KY2 232-0A 3KY2 234-0A
1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit
0.200 0.200 0.315 0.640 0.049 0.049 1.040 0.105

3KY2 232-0A

SENTRON 3KL Switch Disconnectors with Fuses up to 800 A

NSE0_01557b

3 3KL or 3KM basic device Plug-in contact strip for 3KM 3 Fuses, optionally BS-88 or LV HRC fuses Terminal cover, IP20 (vertical to operator side) Coupling driver with extension shaft Standard products from the Siemens 3SB1 range are used as auxiliary switches. Single-pole terminal cover from 63 A to 630 A, IP20 (vertical to operator side)

1) 2) 3) 4) 5) 6) 7) 8) 9) 10)
IEC 60947-1, IEC 60947-3 3KL50 A Size and 000 3KL521) and 000 3KL531) and 000 3KL551) and 2 3KL571) and 2 3KL611) and 2 3KL621) and 2
A V kV V V kA kA A W W kA kA2s
(3 conducting paths series-connected) 220 (2 conducting paths series-connected) 3) 160 11.5 11.305) 305) 50 6304) 60.10500
8 (A2/A3) 11.5 (A4) 17 223
A A kW A A kW A A kW A A kA C C

220 10008) 25010) 8

5100 6306) 6306) 6305) 560 25209) 63010) 32
6400 8006) 8006) 8005) 700 25209) 63010) 32
-25. +55 for operation4), -50. +80 when stored 225 IP00/IP20 (from the operator side, with fuse and terminal covers)

mm mm2 Nm

25 x 6. 7.5 M6 ---

45 x 18. 22 M8 ---

40 x 35. 45 Mx 2.5 70

40 x 15

40 x 17

40 x x M12 ---

2 x 150 or 2 x x 240 35. 45 Mx 2.56 M12 ---
Technical specifications for approval on request. Configuring note: Max. permissible operating temperature for fuse blades 135 C, for connections 100 C. 110 V (one conducting path). With 3KL61 for operation -25 C. +35 C, at +55 C: Ith = 570 A. With 3ND1 switchgear protection fuse. AC-23B. 220 V DC (L1 and L3 series-connected) or 110 V DC (one conducting path) at DC-23A. At 440 V L/R = 4 ms, at 220 V L/R = 15 ms. Only DC-22A (L/R = 2.5 ms) At 440 V DC-22A, at 220 V DC-23A.
Note: For the 3KL switch disconnectors, complete kits for standard and EMERGENCY-STOP application are available for installation in the side and rear panels of control cabinets.
All switch disconnectors with degree of protection IP00 Conductor connecting screws and fuse partitions are generally included in the scope of supply
Rated uninterrupted current Iu LV HRC fuse links1) acc. to DIN 436202) Size A Operational class DT Order No. Price PU per PU (UNIT, SET, M) PS*/ P. unit PG Weight per PU approx.
3-pole for NH fuse systems 6303) 8003) and and and and and and and 23) 3 and 23) 00 and and and and and and 2 Form A2/A3 Form A2/A3 Form A4 Form A4 Form B1-B3 Form B1-B3 Form C1-C3 Form C1-C3 Form A2/A3 Form A2/A3 Form A4 Form A4 Form B1-B3 Form B1-B3 Form C1-C3 gG, aM gG, aM gG, aM gG, aM gG, aM gG, aM gG, aM3) gG, aM3) gG, aM gG, aM gG, aM gG, aM gG, aM gG, aM B B B B B B D C B B C B B B B B B B B B C D B B B B B B C 3KL50 30-1GB01 3KL52 30-1GB01 3KL53 30-1GB01 3KL55 30-1GB01 3KL57 30-1GB01 3KL61 30-1GB00 3KL61 30-1GB02 3KL62 30-1GB02 3KL50 40-1GB01 3KL52 40-1GB01 3KL53 40-1GB01 3KL55 40-1GB01 3KL57 40-1GB01 3KL61 40-1GB00 3KL50 30-1GG01 3KL52 30-1GG01 3KL52 30-1GJ01 3KL53 30-1GJ01 3KL55 30-1GG01 3KL57 30-1GG01 3KL61 30-1GG00 3KL62 30-1GG00 3KL50 40-1GG01 3KL52 40-1GG01 3KL52 40-1GJ01 3KL53 40-1GJ01 3KL55 40-1GG01 3KL57 40-1GG01 3KL61 40-1GG1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 113 1.460 2.414 2.600 6.112 6.067 18.070 15.200 15.200 2.542 2.623 2.776 6.642 6.886 16.690 1.455 2.360 2.406 2.575 6.115 6.582 16.278 15.400 2.563 2.560 2.614 2.780 6.639 7.148 16.996

Standards Type Rated uninterrupted current Iu For fuse links acc. to DIN 43620, (when SITOR semiconductor fuses are used, a reduction of rated current is necessary, see reference to technical information at start of chapter) Conventional free-air thermal current Ith1) Rated insulation voltage Ui Rated impulse withstand voltage Uimp Rated operational voltage Ue 50/60 Hz AC DC Rated short-circuit making capacity with fuses (peak value, at 50/60 Hz 690 V AC) Rated conditional short-circuit current with fuses At 50/60 Hz 690 V AC (rms value) Max. rated current In of the fuses Max. permissible power loss of the installed fuse NH BS Permissible let-through current of the fuses Maximum permissible let-through I2t value Switching capacity (infeed from the top or bottom) At 400 V AC Breaking current Ic (at p.f. = 0.35, rms) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 500 V AC Breaking current Ic (at p.f. = 0.35, rms) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 690 V AC Breaking current Ic (at p.f. = 0.35, rms) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 440 V DC (3 conducting paths series-connected)4) Breaking current Ic (L/R = 15 ms) Rated operational current Ie at DC-23A Rated short-time current (1 s current), rms value Permissible ambient temperature Mechanical endurance, operating cycles Degree of protection Power loss of the switch disconnector at Ith (plus power loss of the fuses) Main conductor connections Busbar systems, max. dimensions (w t) Cable lug, max. conductor cross-section (stranded) Busbar systems, max. dimensions (w t) Tightening torque Terminal screws Protective conductor connections Flat bars Cable lug, max. conductor cross-section (stranded)

1) 2) 3) 4) 5) 6)

IEC 60947-1, IEC 60947-3 3KM50 A Size and 000 3KM00 and 000 3KM00 and 000 3KM1 and 2 3KM1 and 2
A V kV V V V kA kA A W W kA kA2s
440 (3 conducting paths series-connected) 220 (2 conducting paths series-connected) 2) 8 (A2/A3) 11.5 (A4) 160 11.5 11.303) 303) 1000

220 10004) 2505) 8

-25. +55 for operation6) -50. +80 when stored 86 IP00/IP20 (from the operator side, with fuse and terminal covers)

mm mm2 mm Nm

9 6. 7.5 M6

10 7. 10 M6 ---

10 18. 22 M8 ---

12 35. 45 M2.5 70

or 35. 45 M2.5 120
Configuring note: Max. permissible operating temperature for fuse blades 135 C, for connections 100 C. 110 V (one conducting path). 220 V DC (L1 and L3 series-connected) or 110 V DC (one conducting path) at DC-23A. At 440 V L/R = 4 ms, at 220 V L/R = 15 ms. At 440 V DC-22A, at 220 V DC-23A. 3ND1 switchgear protection fuse.
For snapping onto busbars
All switch disconnectors with degree of protection IP00 Mounting on vertical busbars with busbar center-to-center spacing of 60 mm and bar thickness from 5 mm to 6.35 mm Conductor connecting screws and fuse partitions are generally included in the scope of supply.
Complete versions with 8UC7 door-coupling rotary operating mechanisms
3-pole for NH fuse systems (black handle) and and and and and 1 gG, aM gG, aM gG, aM gG, aM gG, aM B B B B B 3KM50 30-1GB01 3KM52 30-1GB01 3KM53 30-1GB01 3KM55 30-1GB01 3KM57 30-1GB1 unit 1 unit 1 unit 1 unit 1 unit 103 1.890 2.860 2.935 5.670 6.938
3-pole for fuses acc. to BS 88 Complete versions with 8UC7 door-coupling rotary operating mechanism (black handle) 400 Form A2/A3 Form A4 Form A4 Form B1-B3 Form B1-B3 C C C C C 3KM52 30-1GG01 3KM52 30-1GJ01 3KM53 30-1GJ01 3KM55 30-1GG01 3KM57 30-1GG1 unit 1 unit 1 unit 1 unit 1 unit 103 2.785 2.340 2.926 6.651 7.175
3-pole for NH fuse systems and and and and and 1 gG, aM gG, aM gG, aM gG, aM gG, aM B B C B B 3KM50 30-1AB01 3KM52 30-1AB01 3KM53 30-1AB01 3KM55 30-1AB01 3KM57 30-1AB1 unit 1 unit 1 unit 1 unit 1 unit 103 1.515 2.450 2.516 5.698 5.966
3KM53 30-1AB01 with fuses 3-pole for fuses acc. to BS 400 3KM55 30-1AG01 with fuses Form A2/A3 Form A2/A3 Form A4 Form A4 Form B1-B3 Form B1-B3 C C C C C C 3KM50 30-1AG01 3KM52 30-1AG01 3KM52 30-1AJ01 3KM53 30-1AJ01 3KM55 30-1AG01 3KM57 30-1AGunit 1 unit 1 unit 1 unit 1 unit 1 unit 1.450 2.405 2.430 2.520 5.689 6.250
400 8UC71 21-3BBand and and and and 1 gG, aM gG, aM gG, aM gG, aM gG, aM B B B B B 8UC71 21-3BB10 8UC72 22-3BB20 8UC72 22-3BB20 8UC73 23-3BB30 8UC73 23-3BB1 unit 1 unit 1 unit 1 unit 1 unit 103 0.200 0.200 0.200 0.200 0.200
8UC7 EMERGENCY-STOP door-coupling rotary operating mechanisms (red handle, yellow indicator plate) Form A2/A3 Form A2/A3 Form A4 Form A4 Form B1-B3 Form B1-B3 B B B B B B 8UC71 21-3BB10 8UC72 22-3BB20 8UC72 22-3BB20 8UC72 22-3BB20 8UC73 23-3BB30 8UC73 23-3BBunit 1 unit 1 unit 1 unit 1 unit 1 unit 0.200 0.200 0.200 0.200 0.200 0.200

@ 12 mm Standard C 8UC74 14-1BF1 unit 103 0.200 8UC74 10-1BF 8UC60 14

@ 12 mm 8UC60 34

@ 12 mm by 12 mm 8UC60 24
@ 12 mm Standard C 8UC74 14-1FG1 unit 103 0.200 8UC74 10-1FG 8UC60 14
@ 12 mm Standard C 8UC74 14-1BB1 unit 103 0.200 8UC74 10-1BB 8UC60 14

Individual parts

Switching device Rotary operating mechanisms Type 8UCSize Crosssection of the actuating shaft mm mm 66 Standard C EMERGENCYSTOP 88 C 8UC71 10-1BB 8UC71 20-3BB 1 unit 1 unit Version4) DT Individual parts for 8UC7 door-coupling rotary operating mechanisms Order No. Price per PU kg 0.200 0.200 PU (UNIT, SET, M) PS*/ P. unit PG Weight per PU approx.
Type 3KL50, 3KM50, 3KA50, 3KA51 8UC71
Handles with masking plate (including flat gasket and fixing screws)
3KL52, 3KM52, 8UC72 3KL53, 3KM53, 3KA52, 3KA53
Standard C EMERGENCYSTOP C
8UC72 10-1BB 8UC72 20-3BB

0.200 0.200

8UC72 3KL55, 3KM55, 8UC73 3KL57, 3KM57, 3KA55, 3KA57, 3KE42, 3KE43, 3KE44, 3KE45 8UC73 3KL61, 3KL62 8UCStandard C EMERGENCYSTOP 8UC74 3KE42, 3KE43, 8UC743) 4 3KE44, 3KE12 C 8UC74 10-1BB 8UC74 20-3BB 1 unit 1 unit 0.200 0.or 12 x 12 Standard C EMERGENCYSTOP C 8UC73 10-1BB 8UC73 20-3BB 1 unit 1 unit 0.200 0.200
Standard C Standard C Standard C
8UC74 10-1BF 8UC74 10-1FG 8UC74 10-1BB Individual parts for 8UC6 door-coupling rotary operating mechanisms Order No. Price per PU

1 PU (UNIT, SET, M)

1 unit 1 unit 1 unit PS*/ P. unit

103 PG

0.200 0.200 0.200 Weight per PU approx. kg
Rotary operating mechanisms
Cross-section of the actuating shaft
Type Coupling drivers for 3K 8UC71 8UC712) 8UC72 8UC722) 8UC73 8UC73/74 8UC71 8UC72 8UC73 8UC73/74
Coupling drivers, extension shafts, shaft couplings and reducers
B A B A B B B B C B 8UC8UC8UC8UC8UC8UC8UC8UC8UC8UC1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.078 0.070 0.075 0.043 0.251 0.253 0.068 0.132 0.217 0.315

8UC60 11

Extension shafts 300 mm long

NSE0_00373

8UC60 31. 34
Extension shafts 600 mm long 8UC71 8UC72 8UC73 8UC73/74 Shaft couplings 8UC71 8UC72 8UC73 8UC73/74 8UC74 (3KL61) Reducers 8UC71 8UC72

ns g_4

ns g0 _45

8UC60 81. 84

B B B B

8UC8UC8UC8UC60 84

1 unit 1 unit 1 unit 1 unit

0.136 0.265 0.430 0.640

NSE00374

Steg 1) Niet 1)

8UCto 8UC6024

to to 8 8

B B B B }
8UC8UC8UC8UC8UC8UC8UC70 50
0.031 0.023 0.085 0.077 0.115 0.200 0.200

8UC70 58

8UC70 50
Non-interchangeability features. Shortened coupling driver with reduced tolerance compensation. For switch disconnectors as changeover switches in various versions, see table on page 7/60

Without auxiliary switches, ammeters, current transformers } 0 0AA0 None

For BS fuse links

00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1)
3NJ62 62-3AA0@-0AA0 3NJ62 72-3AA0@-0AA0 3NJ62 82-3AA0@-0AA0 3NJ62 92-3AA0@-0AA0 3NJ62 62-3AE0@-0AA0 3NJ62 72-3AE0@-0AA0 3NJ62 82-3AE0@-0AA0 3NJ62 92-3AE0@-0AA0 3NJ62 62-4AA0@-0AA0 3NJ62 72-4AA0@-0AA0 3NJ62 82-4AA0@-0AA0 3NJ62 92-4AA0@-0AA0 3NJ62 62-4AE0@-0AA0 3NJ62 72-4AE0@-0AA0 3NJ62 82-4AE0@-0AA0 3NJ62 92-4AE0@-0AA0
3.630 6.750 15.000 15.360 3.830 6.950 15.200 15.560 3.630 6.750 15.000 15.360 4.330 7.450 15.700 16.060
A3 A3 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) C C C C C C C C C C C C C C C C C C C C C C C C C C 3NJ62 43-3AA0@-@@@@ 3NJ62 53-3AA0@-@@@@ 3NJ62 63-3AA0@-@@@@ 3NJ62 73-3AA0@-@@@@ 3NJ62 83-3AA0@-@@@@ 3NJ62 93-3AA0@-@@@@ 3NJ62 63-3AB0@-@@@@ 3NJ62 73-3AB0@-@@@@ 3NJ62 83-3AB0@-@@@@ 3NJ62 93-3AB0@-@@@@ 3NJ62 63-3AC0@-@@@@ 3NJ62 73-3AC0@-@@@@ 3NJ62 83-3AC0@-@@@@ 3NJ62 93-3AC0@-@@@@ 3NJ62 63-4AA0@-@@@@ 3NJ62 73-4AA0@-@@@@ 3NJ62 83-4AA0@-@@@@ 3NJ62 93-4AA0@-@@@@ 3NJ62 63-4AB0@-@@@@ 3NJ62 73-4AB0@-@@@@ 3NJ62 83-4AB0@-@@@@ 3NJ62 93-4AB0@-@@@@ 3NJ62 63-4AC0@-@@@@ 3NJ62 73-4AC0@-@@@@ 3NJ62 83-4AC0@-@@@@ 3NJ62 93-4AC0@-@@@@ Order No. supplement Add. price 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 3.630 3.630 3.630 6.750 15.000 15.360 3.830 6.950 15.200 15.560 3.830 6.950 15.200 15.560 3.630 6.750 15.000 15.360 4.330 7.450 15.700 16.060 4.330 7.450 15.700 16.060
Without auxiliary switches, ammeters, current transformers

0 0AA0

00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1) 00T1) B2 B4 3T1)
C C C C C C C C C C C C C C C C C C C C C C C C
3NJ62 64-1AA0@-@@@@ 3NJ62 74-1AA0@-@@@@ 3NJ62 84-1AA0@-@@@@ 3NJ62 94-1AA0@-@@@@ 3NJ62 64-1AB0@-@@@@ 3NJ62 74-1AB0@-@@@@ 3NJ62 84-1AB0@-@@@@ 3NJ62 94-1AB0@-@@@@ 3NJ62 64-1AC0@-@@@@ 3NJ62 74-1AC0@-@@@@ 3NJ62 84-1AC0@-@@@@ 3NJ62 94-1AC0@-@@@@ 3NJ62 64-2AA0@-@@@@ 3NJ62 74-2AA0@-@@@@ 3NJ62 84-2AA0@-@@@@ 3NJ62 94-2AA0@-@@@@ 3NJ62 64-2AB0@-@@@@ 3NJ62 74-2AB0@-@@@@ 3NJ62 84-2AB0@-@@@@ 3NJ62 94-2AB0@-@@@@ 3NJ62 64-2AC0@-@@@@ 3NJ62 74-2AC0@-@@@@ 3NJ62 84-2AC0@-@@@@ 3NJ62 94-2AC0@-@@@@ Order No. supplement Add. price
1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit

For size NH 3 and BS 3T

Without Moving iron Moving iron
Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without
For size NH 3 and BS 3T (continued)
1 current transformer to 1 ammeter and multi-function plug Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D 1EHEH 2 1EH3 1EH4 1EH5 1EH6 1EJ1 1EJ2 1EJ3 1EJ4 1EJ5 1EJ6 1EK1 1EK2 1EK3 1EK4 1EK5 1EK6 1EL1 1ELE L3 1EL4 1EL5 1EL6 2EH1 2EH2 2EH3 2EH4 2EH5 2EH6 2EJ1 2EJ2 2EJ3 2EJ4 2EJ5 2EJ6 2EK1 2EK2 2EK3 2EK4 2EK5 2EK6 2EL1 2EL2 2EL3 2EL4 2EL5 2EL6 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit
Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal
3 current transformer to 1 ammeter and multi-function plug Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated 1 0.5 0.5 calibrated B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D B B D 1FH1 1FH2 1FH3 1FH4 1FH5 1FH6 1FJ1 1FJ2 1FJ3 1FJ4 1FJ5 1FJ6 1FK1 1FK2 1FK3 1FK4 1FK5 1FK6 1FL1 1FL2 1FL3 1FL4 1FL5 1FL6 2FH1 2FH2 2FH3 2FH4 2FH5 2FH6 2FJ1 2FJ2 2FJ3 2FJ4 2FJ5 2FJ6 2FK1 2FK2 2FK3 2FK4 2FK5 2FK6 2FL1 2FL2 2FL3 2FL4 2FL5 2FL6 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit

3NJ69 00-4GA00 Ammeters Moving-iron measuring instruments for measurements on transformer x/1A with double overload 50 A / 1 A 100 A / 1 A 150 A / 1 A 3NJ69 00-4H. 0.6 VA 0.6 VA 0.6 VA A A A 3NJ69 00-4HB11 3NJ69 00-4HD11 3NJ69 00-4HE1 unit 1 unit 1 unit 143 0.100 0.100 0.100
Moving-iron measuring instruments for measurements on transformer x/5A with double overload 50 A / 5 A 100 A / 5 A 150 A / 5 A 0.6 VA 0.6 VA 0.6 VA A A A 3NJ69 00-4HB21 3NJ69 00-4HD21 3NJ69 00-4HE1 unit 1 unit 1 unit 143 0.100 0.100 0.100
Bi-metal measuring instruments for measurements on transformer x/1A with 1.2-times the overload 50 A / 1 A 100 A / 1 A 150 A / 1 A 1 VA 1 VA 1 VA A A A 3NJ69 00-4HB12 3NJ69 00-4HD12 3NJ69 00-4HE1 unit 1 unit 1 unit 143 0.100 0.100 0.100
Bi-metal measuring instruments for measurements on transformer x/5A with 1.2-times the overload 3NJ69 00-4H. 50 A / 5 A 100 A / 5 A 150 A / 5 A 1 VA 1 VA 1 VA A A A A A A 3NJ69 00-4HB22 3NJ69 00-4HD22 3NJ69 00-4HE22 3NJ69 20-3EB00 3NJ69 20-3ED00 3NJ69 20-3EEunit 1 unit 1 unit 1 unit 1 unit 1 unit 0.100 0.100 0.100 0.047 0.047 0.070
Multi-function plugs 6 x 2.5 mm2, with fixing screws 8 x 2.5 mm2, without fixing screws 10 x 1.5 mm2 and 8 x 2.5 mm2, without fixing screws 3NJ69 20-3EB00

3NJ69 20-3ED00

3NJ69 20-3EE00 Front panel 3NJ69 23-4BB00 For NH: 3NJ62 03-1AA. and 3NJ62 03-3AA. without/with EFM For BS: 3NJ62 03-1AA. and 3NJ62 03-3AA. without/with EFM
3NJ69 23-4BB00 3NJ69 23-4BC00

0.400 0.400

Not available in combination with multi-function plug
Terminals Single terminal for 2-/3-pole devices, 16. 300 mm2 (1 set = 3 units) 3NJ69 33-1BA00 Single terminal for 4-pole devices, 16. 300 mm2 (1 set = 4 units) Terminal covers For 2-/3-pole devices Internal terminal covers for 2-/3-pole devices Only for 4th pole A A A 3NJ69 33-1DA00 3NJ69 33-1DB00 3NJ69 04-1DA1 unit 1 unit 1 unit 143 0.146 0.020 0.070 A A 3NJ69 33-1BA00 3NJ69 34-1BAunit 1 unit 0.230 0.310

3NJ69 33-1DA00

3NJ69 33-1DB00 Contact extensions 3-pole 4-pole 3NJ69 33-1EB00 Electronic fuse monitor and line monitor A A 3NJ69 33-1EB00 3NJ69 34-1EBunit 1 unit 2.400 2.800
A A A 3NJ69 30-3FB00 3NJ69 30-3FC00 3NJ69 30-3FE1 unit 1 unit 1 unit 143 0.400 0.450 0.450

3NJ69 23-3FC00 Auxiliary switches 1 NO contact (1 NO) with cover 1 NO contact (1 NO) 1 NC contact (1 NC) with cover 3NJ69 30-2BBNC contact (1 NC) A A A A 3NJ69 30-2BB00 3NJ69 00-2BC00 3NJ69 30-2CB00 3NJ69 00-2CCunit 1 unit 1 unit 1 unit 0.050 0.020 0.050 0.020
3NJ69 00-2BC00 Current transformers For main devices and contact extensions = Feed-through opening diameter 50 A / 1 A 50 A / 5 A 3NJ69 20-3BDA / 1 A 100 A / 1 A 100 A / 5 A 100 A / 5 A 150 A / 1 A 150 A / 1 A 150 A / 5 A 150 A / 5 A 200 A / 1 A 200 A / 1 A 200 A / 5 A 200 A / 5 A 250 A / 1 A 250 A / 1 A 250 A / 5 A 250 A / 5 A Class 1 Class 1 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.5 Class 1 Class 0.VA, 21 mm 1 VA, 21 mm 2.5 VA, 21 mm 1.5 VA, 21 mm 2.5 VA, 21 mm 1.5 VA, 21 mm 2.5 VA, 21 mm 1.5 VA, 21 mm 1.5 VA, 21 mm 1.5 VA, 21 mm 2.5 VA, 21 mm 5 VA, 21 mm 2.5 VA, 21 mm 2.5 VA, 21 mm 5 VA, 21 mm 5 VA, 21 mm 2.5 VA, 21 mm 2.5 VA, 21 mm A A A A A A A A A A A A A A A A A A 3NJ69 20-3BB11 3NJ69 20-3BB21 3NJ69 20-3BD11 3NJ69 20-3BD12 3NJ69 20-3BD21 3NJ69 20-3BD22 3NJ69 20-3BE11 3NJ69 20-3BE12 3NJ69 20-3BE21 3NJ69 20-3BE22 3NJ69 30-3BF11 3NJ69 30-3BF12 3NJ69 30-3BF21 3NJ69 30-3BF22 3NJ69 30-3BG11 3NJ69 30-3BG12 3NJ69 30-3BG21 3NJ69 30-3BGunit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.160 0.160 0.160 0.160 0.160 0.160 0.170 0.170 0.170 0.170 0.180 0.180 0.180 0.180 0.180 0.180 0.180 0.180
Current transformer busbars for current transformers with feed-through opening 21 mm For 1 current transformers For 3 current transformers 3NJ69 30-3DB00 For 4 current transformers1) A A A 3NJ69 30-3DB00 3NJ69 30-3DC00 3NJ69 30-3DD1 unit 1 unit 1 unit 143 0.210 0.310 0.410

3NJ69 30-3DC00

3NJ69 30-3DD00 Holders for ammeters For sizes 00, 1, 2, 3 A 3NJ69 00-4GA1 unit 143 0.040
3NJ69 00-4GA00 Ammeters Moving-iron measuring instruments for measurements on transformer x/1A with double overload 50 A / 1 A 100 A / 1 A 150 A / 1 A 200 A / 1 A 250 A / 1 A 0.6 VA 0.6 VA 0.6 VA 0.6 VA 0.6 VA A A A A A 3NJ69 00-4HB11 3NJ69 00-4HD11 3NJ69 00-4HE11 3NJ69 00-4HF11 3NJ69 00-4HG1 unit 1 unit 1 unit 1 unit 1 unit 143 0.100 0.100 0.100 0.100 0.100

3NP1 933-1BG30 Auxiliary conductor connection, 0.25. 1 mm2 For box terminal (1 set= 3 units) A 3NP1 933-1BG1 unit 143 0.006

3NP1 933-1BG40

For size NH00 (continued) Device covers, auxiliary switches
Reach-around protection for busbar mounting (1x at top, 1x at bottom) For System Siemens 8US 3NP1 933-1CA10 For System Rittal Cable connection covers (at top and bottom) For flat terminal 3NP1 933-1CB00 Cable connection covers with rear reach-around protection in case of busbar mounting (at top and bottom) For flat terminal A 3NP1 933-1CC1 unit 143 0.093 A A A 3NP1 933-1CA10 3NP1 933-1CA20 3NP1 933-1CB1 unit 1 unit 1 unit 143 0.058 0.044 0.045
3NP1 933-1CD1 unit 143 0.079
3NP1 933-1CC00 Cable connection covers with rear reach-around A protection in case of busbar mounting (at top and bottom) For flat terminal
3NP1 933-1CD00 Masking frame supports (1 set = 2 units) A 3NP1 933-1CF1 unit 143 0.012
3NP1 933-1CF00 System masking frames Dimensions (H x W) 215 x 130 mm Fixing kits For 2 standard mounting rails 125/150 mm A 3NP1 933-1EB1 unit 143 0.009 A 3NP1 933-1DA1 unit 143 0.024
3NP1 933-1EB00 Auxiliary switches 1 CO 1 CO contact, solid-state compatible A A 3NP1 930-1FA00 3NP1 930-1FBunit 1 unit 0.012 0.012
3NP1 930-1FB00 Fuse carriers Standard With electromechanical MFM fuse monitoring With electronic EFM 10 fuse monitoring With electronic EFM 20 fuse monitoring and line monitoring 3NP1 933-1GB10 With electronic EFM 25 fuse monitoring and line monitoring Locking devices (1 set = 10 units) A 3NP1 900-1HA1 unit 143 0.006 A A A A A 3NP1 933-1GA00 3NP1 933-1GB10 3NP1 933-1GB20 3NP1 933-1GB30 3NP1 933-1GB1 unit 1 unit 1 unit 1 unit 1 unit 143 0.165 1.293 0.589 0.611 0.611

For size NH1 Connection

Saddle terminals, 70. 150 mm2 For flat terminal (1 set = 3 units) 3NP1 943-1BA00 Prism terminal single, 70. 150 mm2 For flat terminal (1 set = 3 units) 3NP1 943-1BB10 A 3NP1 943-1BB1 unit 143 0.270 A 3NP1 943-1BA1 unit 143 0.144

3NP1 943-1BB20

Prism terminals double, 2 x 35. 70 mm2 For flat terminal (1 set = 3 units)
Auxiliary conductor connection, 0.25. 1 mm2 For flat terminal (1 set = 3 units) 3NP1 943-1BG10 Auxiliary conductor connection, 0.25. 1 mm2 For saddle-type or prism terminals (1 set = 3 units)

3NP1 943-1BG10

3NP1 943-1BG30
3NP1 943-1BG30 Auxiliary conductor connection, 0.25. 1 mm2 For box terminal (1 set= 3 units) A 3NP1 943-1BG1 unit 143 0.014

3NP1 943-1BG40

Rated Connection types uninter- (on both sides) rupted current Iu Connec- For contion ductor crosssection A mm2 For LV HRC Auxiliary switches fuse links acc. to DIN 436201) On switch disconnector NH size Version On the fuse monitor Version Order No. Price per PU kg DT Degree of protection IP00, without fuse links, without isolating links, with terminal screws PU PS*/ (UNIT, P. unit SET, M) PG Weight per PU approx.
For rated operational voltages Ue from 400 V to 500 V AC, infeed must come from above! Busbars with a width of 12 mm and thickness of 5 mm or 10 mm 160 Flat terminals 2.5. 1202) Connection at bottom 00 and NO + 1 NC 2 NO + 1 NC B 3NP50 65-1HF1 unit 103 2.776

3NP50 65-1HF13

For LV HRC fuse links, see chapter 5 "Fuse Systems". According to DIN 46234 or 16 mm2. 95 mm2 according to DIN 46235 (use M10 cable lug as necessary).
Version For fuse switch disconnectors DT Order No. Price PU per PU (UNIT, SET, M) PS*/ P. unit PG Weight per PU approx. kg Fuse carriers 3NP50 6.-.C.0 3NP52 60-.C.0 3NP53 60-.C.0 3NP54 60-.C.0 With fuse monitoring by 3RV1 MSPs (with auxiliary switch 1 NO + 1 NC), with plug-in connection, without connector and connecting cable 3NYConnector and connecting cable 1 m long 3 m long With electronic fuse monitoring for 400 V. 500 V (with auxiliary switch 2 NO + 1 NC), with plug-in connection, without connector and connecting cable 3NP50 6.-.E.6 3NP52 60-.E.6 3NP53 60-.E.6 3NP54 60-.E.6 B B B B B B B B 3NY3NY3NY3NY3NY3NY3NY3NY1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.620 0.263 1.510 1.690 1.405 1.900 1.980 2.600
3NP5 with 3RV1 B B 3NP50 6.-.H.13 3NP52 60-.H.13 3NP53 60-.H.13 3NP54 60-.H.13 B C B C
3NY3NY3NY1 513-0 3NY1 513-2 3NY1 513-3 3NY1 513-4
0.097 0.261 1.235 2.130 2.146 0.325
3NY1 513-3 Plugs and connecting cables (6-pole) 3 m long 3NP5 with EFM B 3NYunit 103 0.372
3NYAuxiliary switches 1 NO + 1 NC With actuating cams, screws and washers (mounting kit) 3NP501) B 3NYunit 103 0.015
3NYWith fixing bracket and screws (mounting kit) 3NP52. 3NP54 B 3NYunit 103 0.015
3NYArc chute (3 units each are required for 3NP52, 3NP53 and 3NP54) 3NP50 3NP52 3NP53, 3NP54 B B B 3NY3NY3NYunit 1 unit 1 unit 103 0.218 0.215 0.240

3NY4 031

3NYMolded-plastic masking frames As replacement for mask- mm 3NYing frames from assembly mm 3NYkits for installation (without mm 3NYfixing brackets and small parts)

3NY3NY3NY1 104

0.071 0.075 0.084
If retrofitted, drill holes required.
SITOR fuses for 3NP5 fuse switch disconnectors: Assignment table
For switch disconnectors Type Permissible load current1) A 3NP3NP820 3NP400
SITOR fuses NH size Operational class Rated current Rated voltage2) DT
Required conductor crosssection Cu mm 2 1.5 2.2 (40 x 5) 2 (40 x 5) 2 (40 x 5) 2 (50 x 5) 2 (50 x 5) 2 (50 x 5) 2 (40 x 5) 2 (40 x 8) 2 150
A gR/gS gR/gS gR/gS gR/gS gR/gS gR/gS gR/gS gR/gS gR/gS gRgS gR gR/gS gR gR/gS gR gR/gS gR gR/gS gR gR/gS gR gR/gS gR/gS gR gR/gS gR/gS gR gR/gS gR gR/gS gR gR gR/gS gR gR gR gR gR gR gR gR aR aR aR aR gR gR gR gR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR aR 450
V 800 } } } } } } } } } } A } A } A } A A A } A } A A A A A A A A D B A B A A A } } } } } } } } } } } } } } } } A A } } } } A A } } } }
kg 3NE1 813-0 3NE1 814-0 3NE1 815-0 3NE1 803-0 3NE1 802-0 3NE1 817-0 3NE1 818-0 3NE1 820-0 3NE1 021-0 3NE1 022-0 3NE1 022-2 3NE1 224-0 3NE1 224-2 3NE1 225-0 3NE1 225-2 3NE1 227-0 3NE1 227-2 3NE1 230-0 3NE1 230-2 3NE1 331-0 3NE1 331-2 3NE1 332-0 3NE1 333-0 3NE1 333-2 3NE1 334-0 3NE1 435-0 3NE1 435-2 3NE1 436-0 3NE1 436-2 3NE1 437-0 3NE1 437-1 3NE1 437-2 3NE1 438-0 3NE1 438-1 3NE1 438-2 3NE1 447-2 3NE1 438-2 3NE8 015-1 3NE8 003-1 3NE8 017-1 3NE8 018-1 3NE8 020-1 3NE8 021-1 3NE8 022-1 3NE8 024-1 3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3 230-0B 3NE3NE3 232-0B 3NE3NE4 327-0B 3NE4 330-0B 3NE4 333-0B units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 047 0.133 0.124 0.127 0.128 0.126 0.129 0.126 0.124 0.204 0.195 0.195 0.522 0.535 0.518 0.508 0.515 0.533 0.519 0.519 0.687 0.684 0.519 0.689 0.691 0.765 1.000 1.098 1.113 1.038 1.045 1.179 1.031 1.560 1.100 1.067 1.044 1.067 0.193 0.195 0.614 0.196 0.206 0.207 0.195 0.195 0.824 0.258 0.274 0.257 0.261 0.260 0.265 0.274 0.510 0.506 0.513 0.586 0.580 0.513 0.515 0.520 0.580 0.780 1.539 0.682

doc1

Switch disconnectors
Main and EMERGENCY-STOP switches 16 A to 250 A Devices for front mounting, floor mounting with door-coupling rotary operating mechanism, distribution board mounting or in molded-plastic enclosures Front mounting with four-hole and center hole arrangement 3, 4 and 6-pole versions 3LD 3 and 4-pole load transfer switches Solar plant isolators 800 V DC Switch disconnectors 63 A to 1000 A Devices for floor mounting with handle, with door-coupling rotary operating mechanism, in molded-plastic enclosures and for mounting in control cabinet side panels 3 and 4-pole versions 3KA/3KE Accessories for use as load transfer switches and parallel switches 3KA/3KE 17/26 3LD
Switch disconnectors with fuses
Switch disconnectors with fuses up to 800 A Devices for floor mounting with door-coupling rotary operating mechanism and for mounting in control cabinet side panels 3KM versions with isolating plug connector for mounting on vertical busbars 3 and 4-pole versions 3KL / 3KM Suitable for NH and BS 88 fuse systems In-line switch disconnectors with fuses, plug-in type, up to 630 A 3 and 4-pole versions Suitable for NH and BS 88 fuse systems 3NJ62 Manually operated or with motorized operating mechanism Optionally with integrated current transformers, auxiliary switches and electronic fuse monitoring 3NJ62 17/58 3KL 3KM 17/38 17/47
Fuse switch disconnectors
Fuse switch disconnectors up to 630 A Connection components are available for flat connection, saddle-type terminal connection, prism terminal connection and box terminal connection Electromechanical and electronic fuse monitoring with/without network monitoring function Mounting variants for floor mounting and 40/60 mm busbar system 3NP1 In-line fuse switch disconnectors up to 2000 A 1- and 3-pole switchable versions Versions for secondary-side fusing of transformers Connection components are available for flat connection, stud bolt connection, saddle-type terminal connection, prism terminal connection and box terminal connection Versions with/without integratable current transformer Versions with/without electronic fuse monitoring 3NJ4/3NJ5 17/108 3NP1 / 3NP5 17/79

3NJ4/3NJ5

Busbar systems
Systems for 40 mm and 60 mm busbar center-to-center clearance 1, 2, 3, 4 and 5-pole systems For flat copper bars and special profiles up to 1600 A Versions for IEC and UL applications 8US 8US 17/118
Switch Disconnectors, Main and EMERGENCY-STOP Switches
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A

General data

4th contact (N conductor) N or PE/ground terminal, continuous Auxiliary switch 1 NO + 1 NC Rotary operating mechanism, red/yellow Rotary operating mechanism, black Front plate, English/German Terminal cover, three-pole Terminal cover, single-pole

kg 0.169 0.046 0.171 0.046 0.168 0.046 0.311 0.046 0.379 0.046 0.379 0.046 2.000 0.046 2.000 0.046 0.183 0.046 0.171 0.046 0.039 0.168 0.046 0.039 0.311 0.046 0.080 0.379 0.046 0.102 0.379 0.046 0.102 2.000 0.046 0.500 2.000 0.046 0.500

3LD2 530-0TK11

4th contact element as N conductor to be ordered separately; see "Accessories for floor mounting". Auxiliary switches 1 NO + 1 NC to be ordered separately, see "Accessories".

Molded-plastic enclosure

Number and version of the contacts Main Auxiliary contact contact elements elements Base Rated data at terminal 50 Hz. 60 Hz, 380 V. 440 V P/AC-23A Iu DT Order No. Price PU per PU (UNIT, SET, M) PS* PG Weight per PU approx.
Main and EMERGENCY-STOP switches
With N- and/or PE-/ground base terminals Lockable in 0 position with up to 3 padlocks Degree of protection IP65 Rotary operating mechanisms with center-hole mounting For floor-mounted auxiliary switches Metric screw connection 3 -PE + N 7.5 PE + N 9.5 PE + N 11.5 PE + N 22 PE + N 37 PE + N 45 3+N -PE PE PE PE 3LD2 164-0TB53 7.5 9.5 11.100 A A A A A A A A C C A } PE + N A } NO + 1 NC N N N N N N 3+N 1 NO + 1 NC PE 7.5 9.5 11.7.A A A A A A A } PE 9.A } PE 11.C } PE C } N A } N A } Actuator color Black Red/yellow (EMERGENCY-STOP)
3LD2 064-0TB5@ 3LD2 164-0TB5@ 3LD2 264-0TB5@ 3LD2 565-0TB5@ 3LD2 766-0TB5@ 3LD2 866-0TB5@ 3LD2 064-1TC5@ 3LD2 164-1TC5@ 3LD2 264-1TC5@ 3LD2 565-1TC5@ 3LD2 766-0TB5@ +1) 3LD9 280-0C 3LD2 866-0TB5@ +1) 3LD9 280-0C 3LD2 064-1GP5@ 3LD2 164-1GP5@ 3LD2 264-1GP5@ 3LD2 565-1GP5@ 3LD2 766-1GP5@ 3LD2 866-1GP5@ 3LD2 064-1TC5@ +2) 3LD9 200-5C 3LD2 164-1TC5@ +2) 3LD9 200-5C 3LD2 264-1TC5@ +2) 3LD9 200-5C 3LD2 565-1TC5@ +2) 3LD9 200-5C 3LD2 766-1GP5@ +2) 3LD9 280-0C 3LD2 866-1GP5@ +2) 3LD9 280-0C
1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit
0.463 0.463 0.465 0.906 1.890 1.890 0.453 0.487 0.500 0.960 1.890 0.102 1.890 0.102 0.507 0.501 0.488 0.935 1.838 1.843 0.453 0.046 0.487 0.046 0.500 0.046 0.960 0.046 1.838 0.102 1.843 0.102

PE + N 37

Number and version of the contacts Main Auxiliary contact contact eleelements ments Base Rated data at terminal 50 Hz. 60 Hz, 380 V. 440 V P/AC-3 P/AC-23A Iu DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx.
Main and EMERGENCY-STOP switches with rotary operating mechanism (6-pole)
With N- and/or PE-/ground base terminals Degree of protection IP65 Metric screw connection 6 -PE + N 7.5 PE + N 9.5 PE + N 18.1 NO + 1 NC N N 7.5 9.5 9.5 11.5 22.0 9.5 11.5 22.63 A A A A A A 3LD2 165-3VB5@ 3LD2 265-3VB5@ 3LD2 566-3VB5@ 3LD2 165-4VD5@ 3LD2 265-4VD5@ 3LD2 566-4VD5@ 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.880 0.878 2.105 0.914 0.910 2.084

Rotary operating mechanisms Lockable in 0 position with up to 3 padlocks For four-hole mounting, including seal - Black A A A A 3LD9 284-1B 3LD9 284-3B 3LD9 284-1D 3LD9 284-3D 1 unit 1 unit 1 unit 1 unit 0.154 0.152 0.155 0.155

3LD9 284-1B

- Red/yellow For center-hole mounting, including seal and nut - Black - Red/yellow
3LD9 284-3D Mounting tools For center-hole mounting with nut A 3LD9 256-0A units 103 0.027
3LD9 256-0A Switching shafts 6 x 6 mm Length 300 mm Length 600 mm Inscription labels With English/German inscription (MAIN SWITCH/HAUPTSCHALTER) 3LD9 286-1A Without inscription Terminal covers as additional touch protection (also for distribution board mounting) Can be snapped on at top and bottom 3LD9 251-2A (left) 3LD9 251-0A (right) 1-pole 3-pole A A 3LD9 251-2A 3LD9 251-0A 4 units 4 units 0.100 0.009 A A 3LD9 286-1A 3LD9 286-4A units units 0.005 0.054 C C 3LD9 205-0C 3LD9 205-2C 5 units 5 units 0.476 0.476
Version DT 3LDand 3LDPU (UNIT, SET, M) Price per PU 1 unit 1 unit PS* PG Weight per PU approx.

kg 0.101 0.092

4th contact (N conductor) Leading switch-on, lagging switch-off N or PE terminals Continuous 3LD9 280-0B (left) 3LD9 280-2B (right) Auxiliary switches For mounting on the left and/or right, lagging switch-on, leading switch-off 1 NO + 1 NC 3LD9 200-5B For mounting on the left and/or right, lagging switch-on, leading switch-off, with gold-plate contacts for SIMATIC request 1 NO + 1 NC C 3LD9 200-5BF unit 103 0.028 } 3LD9 200-5B unit 103 0.046 } 3LD9 280-2B } 3LD9 280-0B
4th contact (N conductor) Leading switch-on, lagging switch-off N or PE terminals Continuous 3LD9 280-0C (left) 3LD9 280-2C (right) Auxiliary switches For mounting on the left and/or right, lagging switch-on, leading switch-off 1 NO + 1 NC 2 NO 3LD9 200-5C (left) 3LD9 200-6C (right) For mounting on the left and/or right, lagging switch-on, leading switch-off, with gold-plate contacts for SIMATIC request 1 NO + 1 NC Rotary operating mechanisms for four-hole mounting Lockable in 0 position with up to 3 padlocks, including seal Black 3LD9 284-1B Red/yellow Switching shafts 6 x 6 mm Length 300 mm Length 600 mm Inscription labels With English/German inscription (MAIN SWITCH/HAUPTSCHALTER) 3LD9 286-1A Without inscription Terminal covers as additional touch protection (also for distribution board mounting) Can be snapped on at top and bottom 1-pole (1 pack = 4 units) 3LD9 281-2A A 3LD9 281-2A units 103 0.007 A A 3LD9 286-1A 3LD9 286-4A units units 0.005 0.054 C C 3LD9 205-0C 3LD9 205-2C 5 units 5 units 0.476 0.476 A A 3LD9 284-1B 3LD9 284-3B 1 unit 1 unit 0.154 0.152 C 3LD9 200-5CF unit 103 0.028 } } 3LD9 200-5C 3LD9 200-6C 1 unit 1 unit 0.046 0.046 } 3LD9 280-2C unit 103 0.093 } 3LD9 280-0C unit 103 0.102

Rated values reduced in the event of strong harmonics caused by frequency converter operation.
For 8UC7 EMERGENCY-STOP door-coupling rotary operating mechanisms (red handle, yellow indicator plate), see Accessories.
Rated uninterrupted current Iu DT 3-pole, assembly kit for mounting in control cabinet side panel Assembly kits (IP40) Comprising: Lockable handle and three terminal covers for the infeed side Order No. A Price per PU unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 103 PU (UNIT, SET, M) PS* PG Weight per PU approx.
kg 0.591 0.591 0.843 0.843 1.560 1.560 1.560

Black handle

630 B B B B B B B 3KX3 516-2AA 3KX3 516-2AA 3KX3 536-2AA 3KX3 536-2AA 3KX3 556-2AA 3KX3 556-2AA 3KX3 556-2AA
3KA53 30-1AE01 with 3KX3 536-2AA
EMERGENCY-STOP red handle
630 B B B B B B B 3KX3 516-2BA 3KX3 516-2BA 3KX3 536-2BA 3KX3 536-2BA 3KX3 556-2BA 3KX3 556-2BA 3KX3 556-2BA unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 103 0.584 0.584 0.860 0.860 1.590 1.590 1.590
All switch disconnectors with degree of protection IP00 with high speed closing and opening conductor connecting screws are generally included in the scope of supply
Rated uninterrupted current Iu DT 3-pole, operating mechanism and actuation from the front Direct operating mechanisms Order No. A Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg 1 unit 1 unit 1 unit 1 unit 4.210 4.178 7.184 7.838
Complete versions with black handle
B B B B 3KE42 30-0BA 3KE43 30-0BA 3KE44 30-0BA 3KE45 30-0BA

3KE43 30-0BA

B B B B 3KE42 30-0AA 3KE43 30-0AA 3KE44 30-0AA 3KE45 30-0AA 1 unit 1 unit 1 unit 1 unit 3.879 3.870 6.915 7.427
EMERGENCY-STOP red handles + coupling sockets for basic switch versions without handle
250 B B 400 B B 630 B B 1000 B B 8UC+ 3KX2 210-0H 8UC+ 3KX2 210-0H 8UC+ 3KX2 210-0H 8UC+ 3KX2 210-0H 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.146 0.236 0.146 0.236 0.165 0.236 0.165 0.236
Rated uninterrupted current Iu
3-pole, operating mechanism and actuation from the front Door-coupling rotary operating mechanisms (lockable) Order No.

PU (UNIT, SET, M)

Weight per PU approx.

Price per PU

B B B B B B B B 3KE42 30-0GA 3KE43 30-0GA 3KE44 30-0GA 3KE45 30-0GA 3KE42 30-0AA 3KE43 30-0AA 3KE44 30-0AA 3KE45 30-0AA 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 5.032 5.041 7.885 8.532 3.879 3.870 6.915 7.427

630 1000

250, 400, 630, 1000 C 8UC73 24-3BB1 unit 103 0.200
Rated uninterrupted current Iu DT 3-pole, rear operating mechanism and actuation Order No. A Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg
Direct operating mechanisms Direct operating mechanisms (lockable) B B C C 3KE42 30-0CA 3KE43 30-0CA 3KE44 30-0CA 3KE45 30-0CA 1 unit 1 unit 1 unit 1 unit 5.306 5.030 7.395 7.990 B B C C 3KE42 30-0CA 3KE43 30-0CA 3KE44 30-0CA 3KE45 30-0CA 1 unit 1 unit 1 unit 1 unit 5.306 5.030 7.395 7.990

Identical accessories for 3KA switch disconnectors and for 3KL and 3KM switch disconnectors with fuses simplify stock keeping. Please inquire about a special variant with reduced values that is particularly resistant to atmospheres high in sulfur, e. g. in the paper and cellulose processing industries.
3KL switch disconnectors with fuses protect against overload and short-circuits as main and EMERGENCY-STOP switches of switch boards, distribution boards, power supply and motor outgoing feeders. In conjunction with Siemens SITOR semiconductor fuses, they are also used in UPS systems, frequency converters and capacitor control systems. All 3K switch disconnectors are climate-proof and meet the requirements of IEC 60947-1, IEC 60947-3 and VDE 0660 Part 107.
Standards Type Rated uninterrupted current Iu For fuse links acc. to DIN 43620, (when SITOR semiconductor fuses are used, a reduction of rated current is necessary, see Catalog Add-On ET B1 AO 2009) Conventional free-air thermal current Ith2) Rated insulation voltage Ui Rated impulse voltage Uimp Rated operational voltage Ue AC 50 Hz/60 Hz DC Rated short-circuit making capacity with fuses Peak value, at 50 Hz/60 Hz 690 V AC Rated conditional short-circuit current with fuses Rms value, at AC 50 Hz/60 Hz 690 V Max. rated current In of the fuses Max. permissible power loss of the installed fuse NH BS Permissible let-through current of the fuses Maximum permissible let-through I2t value Switching capacity (infeed from the top or bottom) At 400 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 500 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 690 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 440 V DC (3 conducting paths series-connected)7) Breaking current Ic (L/R = 15 ms) Rated operational current Ie at DC-23A Rated short-time current Icw (1 s current, rms value) Permissible ambient temperature Mechanical endurance, operating cycles Degree of protection Power loss of the switch disconnector at Ith (plus power loss of the fuses) Main conductor connections Busbar systems, max. dimensions (w x t) Cable lug, max. conductor cross-section (stranded) Tightening torque Terminal screws Protective conductor connections Flat bars Cable lug, max. conductor cross-section (stranded)

3KX3 5.7-3AA Cover IP20 For 3KL52 3-pole devices Cover IP20 For 3KL53 3-pole devices Fuse partitions (1 set = 5 units) Lyre-shaped fuse covers (1 set = 6 units) } } } B 3KX3 527-0CA02 3KX3 537-0CA02 3KX3 507-0AA01 3KX3 507-0BAunit 1 unit 1 unit 1 unit 0.765 0.765 0.044 0.033

3KX3 507-0BA01

For 3KX3 527-3AA: Not suitable for use with type A4 BS fuses.
Version DT Order No. Price PU per PU (UNIT, SET, M) PS* PG Weight per PU approx. kg 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 0.200 0.200 0.155 0.132 0.265 0.023
Door-coupling rotary operating mechanisms IP65 Black handle, shaft 300 mm EMERGENCY-STOP (yellow/red), shaft 300 mm Operating mechanisms for fixed mounting Black handle, shaft 250 mm Extension shaft 300 mm long Extension shaft 600 mm long Shaft connecting pieces

C C } B B B

8UC72 12-1BB20 8UC72 22-3BB20 3KX3 536-1AA 8UC8UC8UC60 22
3SB14 00-0A Auxiliary switches 1 NO + 1 NC 20 ms leading, 1 NO + 1 NC 2 NO 2 NC Fuse monitor connections (1 set = 6 units) C B C D B 3SB14 00-0A 3KX3 552-3EA01 3SB14 00-0G 3SB14 00-0H 3KX3 505-0AA unit 1 unit 1 unit 1 unit 1 unit 103 0.020 0.019 0.020 0.020 0.014

3KL55/3KL57

Terminal cover For 3-pole devices (1set = 6 units) For 4-pole devices (1set = 8 units) Fuse covers (interlock only detachable in the OFF position) } B } 3KX3 557-3DA01 3KX3 557-3DB01 3KX3 557-3AA unit 1 unit 1 unit 103 0.277 0.362 0.212
3KX3 5.7-3AA Cover IP20 For 3-pole devices Fuse partitions (1 set = 5 units) Door-coupling rotary operating mechanisms IP65 Black handle, shaft 300 mm EMERGENCY-STOP (yellow/red), shaft 300 mm Operating mechanisms for fixed mounting, size 3 Black handle, shaft 250 mm } } 3KX3 557-0CA02 3KX3 557-0AAunit 1 unit 1.235 0.162
8UC73 13-1BB30 8UC73 23-3BB30 3KX3 176-1E

1 unit 1 unit 1 unit

0.200 0.200 0.285
3KX3 176-1E Extension shaft 300 mm long Extension shaft 600 mm long Shaft connecting pieces Auxiliary switches 1 NO + 1 NC 20 ms leading, 1 NO + 1 NC 2 NO 2 NC C B B C B C D 8UC8UC8UC3SB14 00-0A 3KX3 552-3EA01 3SB14 00-0G 3SB14 00-0H unit 1 unit 1 unit 1 unit 1 unit 1 unit 1 unit 102 0.217 0.430 0.085 0.020 0.019 0.020 0.020

3KL61/3KL62

Terminal cover For 3-pole devices (1 set = 6 units) For 4-pole devices (1 set = 8 units) Fuse covers Cover plate Complete covers1) Door-coupling rotary operating mechanisms IP65 Black handle, shaft 300 mm 8UCEMERGENCY-STOP (yellow/red), shaft 300 mm } B A A C } C } Operating mechanisms for fixed mounting, size 5 Black handle, shaft 250 mm Extension shaft 300 mm long Extension shaft 600 mm long Shaft connecting pieces Auxiliary switches 1 NO + 1 NC 2 NO 2 NC

A 3KL(3KL62) 630 (710)3) 630 (710)3) 630 (700)3) 630 (800)3) 630 (800)3) 630 (760)3) 3KL(3KL62) 3KL50 (3KM50) 630 (670)3) 630 (790)3) 210 3KL57 (3KM57) 340 (360)3) (290)4) 380 (400)3) (320) 4) 440 (470)3) (360)4) 500 (530)3) (400)4) 540 (580)3) (400)4) 600 (640)3) (400)4) 630 (720)3) (400)4) 630 (800)3) (400)4) 200 (200)3) (175)4) 260 (260)3) (230)4) 370 (370)3) (340)4) 425 (450)3) (380)4) 600 (630)3) (400)4) 3KL61 (3KL62) 145 (150)3) 180 (190)3) 225 (240)3) 255 (270)3) 330 (345)3) 400 (400)3) 135 (140)3) 180 (190)3) 225 (240)3) 300 (315)3) 425 (450)3) 630 (800)3)

A 500 1000

V A D B A B A A A } } } } } } } } } } } } } } } } A A } } } } A A } A A } } } } } } } } } } } B B B B B B B B B B B C
kg 3NE1 437-0 3NE1 437-1 3NE1 437-2 3NE1 438-0 3NE1 438-1 3NE1 438-2 3NE1 447-2 3NE1 448-2 3NE8 015-1 3NE8 003-1 3NE8 017-1 3NE8 018-1 3NE8 020-1 3NE8 021-1 3NE8 022-1 3NE8 024-1 3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3NE3 230-0B 3NE3NE3 232-0B 3NE3NE3 332-0B 3NE3NE3 334-0B 3NE3NE3NE3 337-8 3NE3 338-8 3NE3 340-8 3NE4 327-0B 3NE4 330-0B 3NE4 333-0B 3NE4 334-0B 3NE3NC2 423-3C 3NC2 425-3 3NC2 427-3 3NC2 428-3 3NC2 431-3C 3NC2 432-3C 3NC8 423-3 3NC8 425-3 3NC8 427-3 3NC8 431-3 3NC8 434-3 3NC8 444-units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 3 units 1.117 1.120 1.153 1.124 1.113 1.184 1.170 1.207 0.205 0.204 0.203 0.205 0.203 0.205 0.213 0.207 0.278 0.277 0.276 0.279 0.276 0.278 0.279 0.279 0.580 0.568 0.573 0.570 0.580 0.585 0.590 0.576 0.720 0.759 0.748 0.753 0.756 0.760 0.762 0.764 0.753 0.753 0.760 0.760 0.754 0.771 0.940 1.057 1.066 1.078 0.940 0.940 1.062 1.063 1.069 1.072 1.069 1.085
2 x (50 x 5) x (50 x 5) 2 x (40 x 5) x (40 x 8) 2 x (30 x 5) 2 x (30 x 5) 2 x (40 x 5) 3
SITOR fuses 3NE3. 3NE8, 3NC2 for 3KL5, 3KL6 and 3KM5

3KL52 (3KM52)

3KL552) (3KM55)2)

3KL61 (3KL62) (3KM57)

2 (60 x 6) 3
Permissible load current in the switch disconnector. In the case of cyclic loads, the currents may have to be reduced again (precise values on request).
Due to the mechanical stress on the relatively long fuse blades, SITOR 3NE41 fuses should be switchable only occasionally and only at zero current. Values in black in brackets apply to 3KL62 switch disconnectors. Values in blue in brackets apply to 3KM switch disconnectors.
For technical specifications and dimensional drawings of the SITOR fuses see Catalog ET B1.
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
All switch disconnectors feature double contact interruption and an isolating distance. As a result, the fuses are de-energized when the switch disconnectors are in the disconnected position. The 3KM switch disconnectors with fuses also feature an isolating plug connector. This facilitates mounting and contact establishment in motor control centers (MCCs) in conjunction with vertical busbars. Generally, all 3K. 5 switch disconnectors can be
secured on the shaft with a padlock to prevent unauthorized reclosing. Identical accessories for 3KA switch disconnectors and for 3KL and 3KM switch disconnectors with fuses simplify stock keeping. Please inquire about a special variant with reduced values that is particularly resistant to atmospheres high in sulfur, e. g. in the paper and cellulose processing industries.
3KM switch disconnectors with fuses protect against overload and short-circuits as main and EMERGENCY-STOP switches of switch boards, distribution boards, power supply and motor outgoing feeders. In conjunction with Siemens SITOR semiconductor fuses, they are also used in UPS systems, frequency converters and capacitor control systems. All 3K switch disconnectors are climate-proof and meet the requirements of IEC 60947-1, IEC 60947-3 and VDE 0660 Part 107.
Standards Type Rated uninterrupted current Iu A For fuse links acc. to DIN 43620, Size (when SITOR semiconductor fuse links are used, a reduction of rated current is necessary, see Catalog Add-On ET B1 AO 2009) Conventional free-air thermal current Ith1) Rated insulation voltage Ui Rated impulse voltage Uimp Rated operational voltage Ue AC 50 Hz/60 Hz DC Rated short-circuit making capacity with fuses (peak value, at 50 Hz/60 Hz 690 V AC) Rated conditional short-circuit current with fuses (rms value, at 50 Hz/60 Hz 690 V AC) Max. rated current In of the fuses Max. permissible power loss of the installed fuse NH BS Permissible let-through current of the fuses Maximum permissible let-through At 400 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 500 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 690 V AC Breaking current Ic (at p.f. = 0.35, rms value) Rated operational current Ie with AC-21A, AC-22A, AC-23A Motor switching capacity AC-23A At 440 V DC (3 conducting paths series-connected)4) Breaking current Ic (L/R = 15 ms) Rated operational current Ie at DC-23A Rated short-time current (1 s current), rms value Permissible ambient temperature Mechanical endurance, operating cycles Degree of protection Power loss of the switch disconnector at Ith (plus power loss of the fuses) Main conductor connections Busbars, max. dimensions (w t) Cable lug, max. conductor cross-section (stranded) Busbars, max. dimensions (w t) Tightening torque Terminal screws Protective conductor connections Flat bars Cable lug, max. conductor cross-section (stranded)

B B B B D B B D B B D B B D B B B B D B B D B B D B B D B B B B D B B D B B D B B D B B B B D B B D B B D B B D
1EB1 1EB4 1ED1 1ED2 1ED3 1ED4 1ED5 1ED6 1EE1 1EEE E3 1EE4 1EE5 1EE6 2EB1 2EB4 2ED1 2ED2 2ED3 2ED4 2ED5 2ED6 2EE1 2EE2 2EE3 2EE4 2EE5 2EEFB FB 4 1FD1 1FD2 1FDFD 4 1FD5 1FD6 1FE1 1FE2 1FE3 1FE4 1FE5 1FE6 2FB1 2FB4 2FD1 2FD2 2FDFD FD FD 6 2FE1 2FEF E3 2FE4 2FE5 2FE6
x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x
Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Moving iron Moving iron
3 current transformer to 1 ammeter and multi-function plug

T1 T2 T3

Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal
Ammeters Current transformers Primary current Secondary current A A Without Without 1 0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.5 } B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B 0AA0 1DB1 1DB4 1DD1 1DD4 1DE1 1DED F1 1DFD G1 1DG4 2DB1 2DB4 2DD1 2DD4 2DE1 2DED FD F4 2DG1 2DG4 0BB1 0BB4 0BD1 0BD2 0BD4 0BD5 0BE1 0BE2 0BE4 0BE5 0B F1 0BF2 0BF4 0BF5 0BG1 0BG 2 0BG 4 0BG5 0CB1 0CB4 0C D 1 0C D 2 0C D 4 0C D 5 0C E 1 0C E 2 0C E 4 0C E 5 0C F 1 0C F C F4 0CF5 0CG1 0CG2 0CG4 0CG5 None x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x Accuracy class DT Order No. supplement 3NJ62.-..-@@@@ Add. price

For size NH 1 and BS B2

Without 250 250
Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Moving iron Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Bi-metal Without Without
Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without
Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without Without
For size NH 1 and BS B2 (continued)
1 current transformer to 1 ammeter and multi-function plug Moving iron 1 Moving iron 1
B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B B

Flat connectors Box terminals 160 3NP1 133-1JC630 Flat connectors Box terminals 3NP1 133-1JC630 Flat connectors Box terminals 160 3NP1 133-1JC00 / and and and 2 C C C C C 3NP1 123-1JC22 3NP1 133-1JC22 3NP1 143-1JC22 3NP1 153-1JC22 3NP1 163-1JC1 unit 1 unit 1 unit 1 unit 1 unit 143 0.940 1.120 2.990 5.130 7./ and and and 2 C C C C 3NP1 133-1JC12 3NP1 143-1JC12 3NP1 153-1JC12 3NP1 163-1JCunit 1 unit 1 unit 1 unit 1.120 2.990 4.900 6./ and and and 2 C C C C 3NP1 133-1JC21 3NP1 143-1JC21 3NP1 153-1JC21 3NP1 163-1JCunit 1 unit 1 unit 1 unit 1.420 3.290 5.430 7./ and and and 2 C C C C 3NP1 133-1JC11 3NP1 143-1JC11 3NP1 153-1JC11 3NP1 163-1JCunit 1 unit 1 unit 1 unit 1.420 3.290 5.200 7.00 / and and and 2 A A A A A 3NP1 123-1JC20 3NP1 133-1JC20 3NP1 143-1JC20 3NP1 153-1JC20 3NP1 163-1JC1 unit 1 unit 1 unit 1 unit 1 unit 143 0.820 0.980 2.850 4.990 7./ and and and 2 A A A A 3NP1 133-1JC10 3NP1 143-1JC10 3NP1 153-1JC10 3NP1 163-1JCunit 1 unit 1 unit 1 unit 0.980 2.850 4.760 6.840
Flat connectors Box terminals 160 3NP1 133-1JC00 / and and and 2 C C C C C 3NP1 123-1JC23 3NP1 133-1JC23 3NP1 143-1JC23 3NP1 153-1JC23 3NP1 163-1JC1 unit 1 unit 1 unit 1 unit 1 unit 143 0.940 1.120 2.990 5.130 7./ and and and 2 C C C C 3NP1 133-1JC13 3NP1 143-1JC13 3NP1 153-1JC13 3NP1 163-1JCunit 1 unit 1 unit 1 unit 1.120 2.990 4.900 6.980
3NP1 for industrial applications, power distribution Accessories
For size NH000 Connection methods
Feeder terminals, 16. 95 mm2 (1 set = 3 units) A 3NP1 923-1BD1 unit 143 0.097
3NP1 923-1BD00 Three-tier terminals, 3 x 2.5. 16 mm2 for box terminal (1 set = 3 units) A 3NP1 923-1BE1 unit 143 0.134
3NP1 923-1BE20 Covering caps for 1 blank space on a three-phase busbar (1 set = 20 units) 3NP1 923-1BF10 Three-phase busbars Iu = max. 225 A (1 set = 5 units) For 2 x NH000 3NP1 933-1BF30 For 3x NH000 For 4x NH000 Link rails, Iu = max. 225 A (1 set = 3 units) for three-phase busbars 3NP1 933-1BF50 Auxiliary conductor connection, 0.25. 1 mm2 (1 set = 3 units) for box terminal A 3NP1 923-1BG1 unit 143 0.004 A A A A 3NP1 923-1BF20 3NP1 923-1BF30 3NP1 923-1BF40 3NP1 923-1BFunit 1 unit 1 unit 1 unit 0.268 0.436 0.650 0.263 A 3NP1 923-1BF1 unit 143 0.012
For size NH000 (continued) Device covers, auxiliary switches
Reach-around protection for busbar mounting (1x at top, 1x at bottom) For system Siemens 8US For system Rittal 3NP1 923-1CA10 Cable connection covers only for busbar systems 40 mm / 60 mm, top and bottom A 3NP1 923-1CB1 unit 143 0.039 A A 3NP1 923-1CA10 3NP1 923-1CAunit 1 unit 0.048 0.053

3NP1 933-1CF00 System covers Fixing kits For 2 standard mounting rails 125/150 mm A 3NP1 933-1EB1 unit 143 0.009 Dimensions (H x W) 215 x 130 mm A 3NP1 933-1DA1 unit 143 0.024
3NP1 933-1EB00 Auxiliary switches 1 CO 1 CO, solid-state compatible A A 3NP1 930-1FA00 3NP1 930-1FBunit 1 unit 0.012 0.012
3NP1 930-1FB00 Fuse carriers Standard With MFM electromechanical fuse monitoring With electronic EFM 10 fuse monitoring With electronic EFM 20 fuse monitoring and line monitoring 3NP1 933-1GB10 With electronic EFM 25 fuse monitoring and line monitoring Locking devices (1 set = 10 units) A 3NP1 900-1HA1 unit 143 0.006 A A A A A 3NP1 933-1GA00 3NP1 933-1GB10 3NP1 933-1GB20 3NP1 933-1GB30 3NP1 933-1GB1 unit 1 unit 1 unit 1 unit 1 unit 143 0.165 1.293 0.589 0.611 0.611
For size NH1 Connection methods
Saddle terminals, 70. 150 mm2 for flat connector (1 set = 3 units) 3NP1 943-1BA00 Prism terminals single, 70. 150 mm2 for flat connector (1 set = 3 units) 3NP1 943-1BB10 Prism terminals double, 2 x 35. 70 mm2 for flat connector (1 set = 3 units) A 3NP1 943-1BB1 unit 143 0.311 A 3NP1 943-1BB1 unit 143 0.270 A 3NP1 943-1BA1 unit 143 0.144
3NP1 943-1BB20 Auxiliary conductor connection, 0.25. 1 mm2 for flat connector (1 set = 3 units) 3NP1 943-1BG10 Auxiliary conductor connections, 0.25. 1 mm2 For saddle-type or prism terminals (1 set = 3 units) A 3NP1 943-1BG1 unit 143 0.004 A 3NP1 943-1BG1 unit 143 0.009
3NP1 943-1BG30 Auxiliary conductor connection, 0.25. 1 mm2 for box terminal (1 set = 3 units) A 3NP1 943-1BG1 unit 143 0.014

3NP1 943-1BG40

For size NH1 (continued) Device covers, auxiliary switches
Reach-around protection for busbar mounting (1x at top, 1x at bottom) 3NP1 943-1CA10 For system Siemens 8US For system Rittal Cable connection covers (at top and bottom) A A A 3NP1 943-1CA10 3NP1 943-1CA20 3NP1 943-1CB1 unit 1 unit 1 unit 143 0.024 0.034 0.172
3NP1 943-1CB00 Cable connection covers with rear reach-around protection (at top and bottom) A 3NP1 943-1CD1 unit 143 0.277
3NP1 943-1CD00 Cover supports (1 set = 2 units) System covers Dimensions (H x W) 375 x 220 mm Fixing kits For 2 standard mounting rails 125/150 mm A 3NP1 943-1EB1 unit 143 0.017 A 3NP1 943-1DA1 unit 143 0.092 A 3NP1 943-1CF1 unit 143 0.026

Clamp ter- 1 conductor 00 and 000 minal 2.5. 50 or 2 conductors 1 2.5. 2.5. 35 Connection at bottom
For LV HRC fuse links, see Catalog ET B1. For accessories and more devices on busbar systems, see "Accessories". According to DIN 46234 or 16 mm2. 95 mm2 according to DIN 46235 (use M cable lug if necessary).
3NP5 for extended technical requirements For 60 mm busbar system
Note: For switch versions "For installation in any distribution board" and busbar adapters see page 17/107.
3NP5 for extended technical requirements With fuse monitoring
Fuse monitoring by circuit breaker Floor mounting
Rated uninterrupted current Iu Connection types (on both sides) For LV HRC fuse links acc. to DIN 436201) Auxiliary switch DT Degree of protection IP00, without fuse links, without isolating links, with terminal screws PU (UNIT, SET, M) PS* PG Weight per PU approx.

Connection

For conductor crosssection mm2 Size
On switch On MSP/ disconcircuit nector breaker Version Version Order No. Price per PU kg
Completely compartmentalized, with high speed closing features with fuse monitoring by SIRIUS motor starter protector
With plug-in connection of the auxiliary switch connecting cable (length approx. 1 m) to the circuit breaker 160 Flat con- 2.5. 1503) 00 and 000 nectors2) 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO 1 NO + 1 NC 2 NO } B B B 3NP50 60-0EA86 3NP50 60-0EA26 3NP50 60-0EB86 3NP50 60-0EB1 unit unit unit unit 2.484 2.550 2.616 2.650
Clamp 1 conductor 00 and 000 terminals 2.5. conductor 1 2.5. 2.5. Flat con- 6. 1504) nectors 1 and 0
1 NO + 1 NC 2 NO 1 NO + 1 NC 2 NO

} B B B

3NP52 60-0EA86 3NP52 60-0EA26 3NP52 60-0EB86 3NP52 60-0EB26

unit unit unit unit

6.014 6.867 7.095 6.659
Clamp 35. 120 terminals 3NP52 60-0EAFlat con- 6. 2404) nectors

1 and 0

2 and 1

1 NO + 1 NC 2 NO

3NP53 60-0EA86 3NP53 60-0EA26

unit unit

7.083 5.410
3NP53 60-0EAFlat con- 6. 2 nectors 2404) 3 and NO + 1 NC 1 NO + 1 NC 1 NO + 1 NC 2 NO } B 3NP54 60-0EA86 3NP54 60-0EA1 unit unit 8.462 9.233

3NP54 60-0EA86

For LV HRC fuse links, see Catalog ET B1. For 3NPwith flat connectors, appropriate 3NYcable lug covers must be used to provide finger-safe cover, according to DIN VDE 0106 Part 100 (see Accessories). According to DIN 46234 or 16 mm2. 95 mm2 according to DIN 46235 (use M10 cable lug if necessary). According to DIN 46234 or DIN 46235, with cable lug to DIN 46235: Min. conductor cross-section 16 mm2 (use M12 cable lug if necessary).

17/127

Base assemblies up to 630 A
60 mm busbar system: Base assemblies up to 630 A
Description DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg % Busbar supports End and intermediate holders for flat copper profiles 12 mm x 5 mm, 12 mm x 10 mm, 15 mm x 5 mm, 15 mm x 10 mm, 20 mm x 5 mm, 20 mm x 10 mm, 25 mm x 5 mm, 25 mm x 10 mm, 30 mm x 5 mm, 30 mm x 10 mm 1-pole, in addition for copper profiles 6 x 6 mm, mounting on 8US1923-2AA01 3-pole busbar supports or free standing PE/N A 8US19 23-1AA10 units 143 0.200

8US19 23-1AA01

3-pole, with outside fixing 3-pole, with inside fixing

L1L3 L1L3

8US19 23-2AA01 8US19 23-3AA01

10 units 10 units

8US19 23-3AA01
4-pole, with inside fixing 2-pole, with outside fixing

L1L3 + PE/N

8US19 23-4AA00 8US19 23-5AA00

0.269 0.200

8US19 23-5AA00

17/128

Description Length Width DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Weight per PU approx. kg
mm & End covers For covering unterminated busbar ends For 8US19 23-2AA01 or 8US19 23-3AA01 4-pole, for 8US19 23-4AApack = 2 units (1x right, 1x left) For 5SHholder Height 230 mm (3-pole) 8US19 22-1AC00 5SHHeight 290 mm (4-pole or 3-pole + cable duct), 1 pack = 2 units (1x right, 1x left) ( Cover profiles for busbars 12 mm 5 mm 1000 L1L3 L1L3 + PE/N
8US19 22-1AC00 8US19 22-1AB00

10 units 1 unit

0.020 0.055

5SH5SH3 534

4 units 4 units

016 016

0.038 0.048

8US19 22-2CA00

8US19 22-2CAmm 5 mm, 20 mm 5 mm, 25 mm 5 mm, 30 mm 5 mm 1000 A 8US19 22-2AA10 units 143 0,156
8US19 22-2AAmm x 10 mm, 15 mm x 10 mm, 20 mm 10 mm, 25 mm x 10 mm, 30 mm 10 mm For 5SHand 5SH1000 A 8US19 22-2BA10 units 143 0,105
+ Holders for edge profiles and partitions B 5SHunits 016 0,106
5SHEdge profiles1) - For base 230 mm mm 36 mm, for 3-pole version 5SH- For base 290 mm mm 36 mm, for 4-pole version 5SH) Supports (for blanking covers) Mounting on busbar (2 units per section of blanking cover) B 5SHunits 016 0.040 C 5SHunits 016 0.583 B 5SHunits 016 0.311
5SH* Blanking covers Mounting on 5SHsupport for 1000 blanking covers 202 A 5SHunits 016 0.075

5SH3 537

When configuring a 3-pole busbar system with the base 230 mm, only 5SHis required. When configuring a 4-pole busbar system (or a 3-pole with cable duct) with the 290 mm base, - 5SHand , 5SHare required.

 

Tags

Quattro 70-47 7600GT Salton LM8 Environment MAX-A55 R 153S KDL-55EX713 Casio 3071 EX 800 HT-170 ICN320 FLM-4034B ZDF200 Alliance 2 Doro 915C Siemens SL42 UBT780 CQ-RDP113N GMP32G5 Civilization 4 KDL-46EX501 Server EX-H10 Workcentre 7242 TX-L37g10E Tntsat Drive TM 808 Alcatel 4200 Sp6000 I865G Konstanz CD31 Nordic R HCD-EC70 Phaser 600 TFT1501 TC-WE405 Tracker DSR-450wspl Samsung ST61 PCG-X18 B1524 CQ-RD25 TX-14P1F Zikmu PS-6100 WD-80150NUP ZDM6814 Reference 30 M-480 Edition CK135M RW750 PC5010 Nilfisk 90C ICF-SW40 Contisys OBD Headset H350 P-3030 VP-X300L Manager EMP-1825 Merlin 3000 Warrior KH 2158 Kardon 330B Donna S1900 Canoscan-4400F FAX180 1100DF Scattergories Fostex FR2 F5D8235ed4 Aa-v15 Systems 21GR2554 KDC-W4034AY 42 U Review Ur3 TTP Fostex PH-5 Manager EMP-820 Travelmate-C100 Model 2600 ZIP-1000 Tivoli 63 Fandango VGP-BPS2C Bravada 2002 FT-7B Extensa-4220 Sp-MNM-003 Bizhub 190F CPX1200 T1954 Laserjet 4L TV-850 Lugf02-90-S

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 