Reviews & Opinions
Independent and trusted. Read before buy Sony MDX-C800REC!

Sony MDX-C800REC


Bookmark
Sony MDX-C800REC

Bookmark and Share

 

Sony MDX-C800RECAbout Sony MDX-C800REC
Here you can find all about Sony MDX-C800REC like manual and other informations. For example: review.

Sony MDX-C800REC manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Sony MDX-C800REC please write about it to help other people.
[ Report abuse or wrong photo | Share your Sony MDX-C800REC photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
Sony MDX-C800rec Car Audio, size: 2.4 MB
Related manuals
Sony MDX-C800rec Installation Guide
Sony MDX-C800rec Annexe 1

 

Sony MDX-C800REC

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

MDX-C800REC

SERVICE MANUAL

SUPPLEMENT-1
File this supplement with the service manual.
AEP Model UK Model E Model
Subject : Electrical Adjustments

ELECTRICAL ADJUSTMENT

TEST MODE
This set has the test mode functionality. The test mode should be always set before performing adjustments. <Setting the Test Mode> 1. Input the specified voltage (14.4 V) to the ACC and BATT terminals. 2. 1:00 is displayed on the LCD display. 3. Press 4 key. 4. Press 5 key. 5. Press 1 key for more than 2 seconds. 6. All segments are lit on the LCD display entering the test mode. <Releasing the Test Mode> 1. Press OFF key. ADJUSTMENT mode: SHUF indication off Key Description of test 2 Laser power adjustment mode ENTER DSPL Traverse adjustment mode Focus bias adjustment mode STOP Switch the mode CLV jitter measurement Select the display
PLAY mode: SHUF1 Key Description of test 2 Laser power check mode ENTER DSPL REC mode: SHUF2 Key 6 ENTER DSPL Focus + CLV ON Tracking servo ON/OFF STOP Switch the mode CPLAY mode (middle/outer/inner area) Select the display

DISPLAY TEST

1. Once the test mode is set, each pressing of the DSPL key will cause the LCD display to change as follows:
All segments ON Press DSPL key. Half segments ON (1) Press DSPL key. Half segments ON (2) (The other half segments that were OFF in (1) are ON.) Press DSPL key. All segments OFF Press DSPL key.
Description of test Laser power check mode Focus + CLV ON Tracking servo ON/OFF STOP Switch the mode CREC mode (middle/outer/inner area) Select the display

TEST MODE STRUCTURE

1. Set the test mode. 2. Insert a disc and press 5 key. 3. Each time 6 key is pressed, the mode will change as follows:

Unused mode: SHUF ALL

ADJUSTMENT mode SHUF indication off Press 6 key. PLAY mode SHUF1 indication is lit. Press 6 key. REC mode SHUF2 indication is lit. Press 6 key. Unused mode SHUF ALL indication is lit. Press 6 key.

NOTES FOR ADJUSTMENT

1. Perform the following adjustments as listed when the optical pickup and IC400, IC402 and/or IC440 in the MD SERVO board have been replaced: (1) Laser power adjustment (2) Traverse adjustment (3) Focus bias adjustment (4) CD error rate check (5) MO error rate check 2. Set the test mode to perform these adjustments. Release the test mode after the adjustments are completed. 3. Perform the adjustments in the order that they are listed. 4. Use the following jigs and measuring equipment: Test disc (special disc for playback) TDYS-1 (Part No.: 4-963-646-01) Laser power meter LPM-8001 (Part No.: J-2501-046-A) Oscilloscope (Measure after the probe is calibrated.) Digital voltmeter 5. When observing multiple signals with an oscilloscope or other equipment, take care to prevent connection between VC and ground in the oscilloscope. (Otherwise, VC and ground are shorted.)
PREPARING A CONTINUOUSLY RECORDED DISC
This disc is used for focus bias adjustment and error rate check. This disc is prepared as follows: 1. Set the test mode. (See page 2.) 2. Insert a commercial disc (blank) and press 5 key. 3. Press 6 key twice to set the REC mode. (Verify that the SHUF2 indication is lit on the LCD display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits are displayed). 5. Press ENTER key three times and verify that there is no disc number displayed (the disc is recorded from the inner area). If 3 or 7 is displayed, press ENTER key again to clear the indicator. LCD display

SHUF 2

Disc No. indicator

REC mode

6. Record the data until the disc number indicator shows 9 and then press 5 key to stop recording. 7. Press Z key and take out the disc. The continuously recorded disc for focus bias adjustment and error rate check is now prepared. Note: Take care to prevent vibrations during continuous recording.

For the measurement points, see page 7.

LASER POWER ADJUSTMENT

Connection:

laser power meter

<Setting the read power reference value> 8. Press 2 key. LCD display
optical pick-up objective lens digital voltmeter MD servo board TP (I+3V) TP (IOP)
Mode No. 0.7 mW power (LD Power Adj.)
Procedure: <Setting the write power reference value> 1. Connect a digital voltmeter between TP (I+3V) and TP (IOP). 2. Set the test mode. (See page 2.) 3. Insert a laser power meter into the disc insertion port and press 5 key. 4. Press 2 key. LCD display
9. Use DISC + or DISC key to adjust so that the reading on the laser power meter is 0.69 to 0.71 mW. 10. Press + > M key for 2 seconds to save the data that has been set in step 9. 11. Press 2 key. LCD display
Mode No. Main beam conversion power (LD Power Adj.)
12. Verify that the reading on the laser power meter is 6.0 to 6.4 mW. If outside the specified value, adjust again from step 1. 13. Press 2 key. The laser power adjustment is completed.
Mode No. 7.0 mW power (LD Power Adj.)
5. Use DISC + or DISC key to adjust so that the reading on the laser power meter is 6.9 to 7.1 mW. 6. Press + > M key for 2 seconds to save the data that has been set in step 5. 7. Verify that the digital voltmeter reads out the specified value. Specified value: Reading on the digital voltmeter: Optical pick-up label indication value 10%
(Optical pick-up label) KMS-263A 27X93 B0825
In this case, Iop = 82.5 mA Iop (mA) = Reading on the digital voltmeter (mV)/1 ()

TRAVERSE ADJUSTMENT

oscilloscope MD servo board TP (TE) TP (VC)

FOCUS BIAS ADJUSTMENT

Procedure: 1. Set the test mode. (See page 2.) 2. Insert the continuously recorded disc (see page 3.) and press 5 key. 3. Press 4 key and check the error rate in the current focus bias setting. LCD display
+ V: 0.5 V/div H: 10 ms/div Input: DC mode
Procedure: 1. Connect an oscilloscope between TP (TE) and TP (VC). 2. Set the test mode. (See page 2.) 3. Insert the test disc TDYS-1 and press 5 key. 4. Press 3 key. LCD display
Mode No. Represents the Indicates the (Focus Bias Adj.) initial measurement C1 error rate

<Setting the focus bias point A> 4. Verify that the first digit of the C1 error rate are 0. Then, press 4 key. LCD display
Mode No. Represents Initial set value Value after (EF-B Adj.) EF adjustment automatic adjustment
Mode No. Represent the Indicates the C1 error rate (Focus Bias Adj.) point A measurement
5. The traverse is automatically adjusted. Verify that the waveform of the oscilloscope meets the specified value. 6. If outside the specified value, use DISC + or DISC to adjust the waveform. Pressing of DISC + or DISC will cause the value after automatic adjustment to be varied.
(Traverse waveform) A VC B Specification: A = B
5. Press DISC + key until the C1 error rate value reaches 1.00 (Note 1). 6. Press + > M key for 2 seconds to save the data set in step 5. <Setting the focus bias point B> 7. Press 4 key. LCD display
7. Press + > M key for 2 seconds to save the data set in steps 5 and 6. After saving the data, verify that the initial set value is equal to the value after automatic adjustment. 8. Press 3 key. The traverse adjustment is completed.
Mode No. Represents the Indicates the C1 error rate (Focus Bias Adj.) point B measurement
8. Press DISC key until the C1 error rate value reaches 1.00 (Note 1). 9. Press + > M key for 2 seconds to save the data set in step 8. 10. Press 4 key. LCD display
Mode No. Represents the Indicates the C1 error rate (Focus Bias Adj.) calculated point C measurement
11. Verify that the calculated point C error rate is 0.30 or less. If more than 0.30, adjust again from step 1. 12. Press 4 key. The focus bias adjustment is completed. Note 1) Since the C1 error rate varies, the average should be read to perform this adjustment. Note 2) The relationship between C1 error rate and focus bias amount is shown in the figure below. Find out the points A and B in the above adjustment. The total focus point C is automatically calculated from the points A and B.

C1 error rate 100

MO ERROR RATE CHECK
Procedure: 1. Set the test mode. (See page 2.) 2. Insert the continuously recorded disc (see page 3.) and press 5 key. 3. Press 6 key to set the PLAY mode. (Verify that the SHUF1 indication is lit on the display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits are displayed). 5. Press ENTER key and verify that the disc No. indicator shows 3. If 7 is shown or there is no display, repeatedly press ENTER key until 3 is displayed. LCD display

Focus bias amount A (F. BIAS)

SHUF 1

PLAY mode

C1 error rate

CD ERROR RATE CHECK
Procedure: 1. Set the test mode. (See page 2.) 2. Insert the test disc TDYS-1 and press 5 key. 3. Press 6 key to set the PLAY mode. (Verify that the SHUF1 indication is lit on the display.) 4. Verify that no number is displayed at the disc No. indicator. If any number is displayed, repeatedly press DSPL key until the number disappears (only two digits are displayed). 5. Press ENTER key and verify that the disc No. indicator shows 3. If 7 is shown or there is no display, repeatedly press ENTER key until 3 is displayed. LCD display
6. Verify that the C1 error rate is 0.30 or less. 7. Press 5 key. The MO error rate check is completed.
6. Verify that the C1 error rate is 0.30 or less. 7. Press 5 key. The CD error rate check is completed.

Measurement points:

MD SERVO BOARD (SIDE A)

9-870-144-81

Sony Corporation
Audio Entertainment Group
2000F0455-1 Printed in Japan 2000. 6 Published by ME General Engineering Dept.

 

Tags

Alesis AI3 TM-IP5600 DTA100 S70408-KG Quad 34 GR-M492YLY WID 3000 86435 5000 RSM ETW4100SQ XC1000 KX-FLB801 GTK 2004 Satellite M50 Scanmaker 4700 Omron CQM1 HDC-TM20 IC-2E Prophet VS S9500 Sapt956 CN-HW830D GF-650 Omron E5EK 7996-500 PDF MC-8088HL SFP 630 Radiata-stories CQ-MR555LEN Drawer Ascom I62 UE55C9000ZW Sector MAP MDS-S41 BAR206A CDX-P1280 Frisquet TGP CLD-D504 Cabriolet LG XD63 Transformer TNT T55 505II WL-404 AVH-P5100DVD 32LF2500 RH1999H GT1417DV PS-P2 0 DVD-V7070 80383 HR2811FT Ixus I5 F-401S 32PW9617 12 5520G Microphone FE-10 32PFL3403 12 LV4265 LMS-160 MAP EWV401 Speaker Geist GSM7312 FLS1072C GR-D40 LHT854 DJ-175 KDL-40LX900 SKY Plus 1800-100 HK-DP1eu Rrus551 Olympus X-41 SDM-HS94p B Q5030 SP-P300ME Companion 2 X-drive II CJ-N75CL LAV40800 Golive CS2 Samsung C260 Conroe945G-DVI AX-470 DCD5505W Office AZ1574 LE32A430t1 600 E PCI-424 Serie 03 Vivicam 3350 Review TDA-7560R Mediaboard PRO Bamboo FUN ECM-CG1 Controller YP-U4QB

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 