Tandberg 220-420LTO
|
|
Bookmark Tandberg 220-420LTO |
Here you can find all about Tandberg 220-420LTO like manual and other informations. For example: review.
Tandberg 220-420LTO manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Tandberg 220-420LTO please write about it to help other people. [ Report abuse or wrong photo | Share your Tandberg 220-420LTO photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Tandberg 220-420LTO - Quick Installation Guide, size: 205 KB |
Tandberg 220-420LTO
User reviews and opinions
| ncaew |
6:21pm on Tuesday, October 12th, 2010 ![]() |
| 100 MB USB ZIP DRIVE The USB 100 MB ZIP Drive worked perfectly as soon as I had plugged into a spare port. Now I can see my old photos. no happy Compre este producto como nuevo (new) y me enviaron uno usado (used) Iam no happy , sorry!!!! | |
| Athena |
11:41am on Tuesday, August 31st, 2010 ![]() |
| It enabled my use of over 20 zip disks I already owned ! The original installation disks that came with my order were not for Windows XP. Mis-information Imation Corp 1PK 52X CD-R 700 MB 80 MIN ( 17331 ) If I was not so tired when I made the order. | |
| rbauer |
12:41pm on Sunday, August 22nd, 2010 ![]() |
| I was pleased with the price, the speed of delivery, and the quality of the zip cartridges I purchased. Future Computers is a wonderful outfit. | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

220/420LTO Tandberg 220/420LTO
Half Height LTO1 and LTO2 Tape Drive
Quick Installation Guide
Revision 4b April 2007
Mechanical Installation
For mechanical mounting specifications, please refer to Figure 1. Allowed mounting position is either horizontal with the indicator LEDs to the right, or vertical with the LEDs up. The drive occupies a half-size 5.25-inch slot with standard holes for mounting screws on both sides of the drive chassis and at the bottom of the drive.
Figure 1
Important! Mounting screw requirements
Mounting specifications
Only M3 (metric) screws must be used for mounting the drive Maximum permitted screw penetration: 2.5 mm Minimum required screw penetration: 2.0 mm Screw torque, mounting screws: 0.5 Nm Screws are supplied with all the Tandberg 220/420LTO drive variants Bags with 4 screws and 4 SCSI ID jumpers are available (Ordering no. 65)
Do not use longer screws or higher screw torque than specified!
Figure 2
Allowed mounting orientations
SCSI Identification
Make sure that the drive unit has the proper SCSI-ID before it is connected to a computer system. Refer to manuals for host computer and application software to obtain the correct ID. For correct mounting of ID-jumpers at the rear of the drive, please refer to Figure 3 and Table 1. External drives have a thumb-wheel switch to set the SCSI-ID (see Figure 6).
Power Connector
Service Connector
SCSI Connector
Figure 3 The factory default drive number setting is SCSI ID = 2. If the drive has to be set up with a different unit number, the jumpers (on the Service Connector) have to be connected according to Table 1. Example: SCSI ID = 3
Drive connectors
SCSI ID=0 SCSI ID=1 SCSI ID=2 SCSI ID=3 SCSI ID=4 SCSI ID=5 SCSI ID=6 SCSI ID=7 SCSI ID=8 SCSI ID=9 SCSI ID=10 SCSI ID=11 SCSI ID=12 SCSI ID=13 SCSI ID=14 SCSI ID=15
Table 1 Service Connector jumper settings for SCSI ID (Dark = Jumper mounted) 3
SCSI Cable
Host Internal Terminator Connector Last SCSI Device SCSI-bus 10 cm
Figure 4
SCSI cable (Ordering no. 51) (Ordering no. 53) (Ordering no. 17) (Ordering no. 64)
Internal SCSI-LVD/SE-cable with 5 connectors Internal, removable SCSI-LVD/SE-terminator External, removable SCSI-LVD/SE-terminator External SCSI 68HD/VHDCI 320MBs-cable
Termination
The SCSI-bus cable must be terminated in both ends according to SCSI specifications. If the tape drive is the last device on the bus, the bus must be terminated within 10 cm of the tape drive connection. Tandberg 220/420LTO has a combined SCSI-LVD/SE interface embedded. The PC-98 Specification specifies that the termination of the SCSI-bus system is a part of the SCSI-cable and not a part of the SCSI-device. As a result, termination cannot be turned on or off directly on the tape drive itself. For internal devices, a SCSI-cable with an integrated terminator or a separate terminator applied to the end connector of the cable, 10 cm from the last device, must be used. External devices must be terminated with an external terminator on the last device on the SCSI-bus.
Software Installation
For Software Application support and software drivers, please see www.tandberg.com. Then select SUPPORT and Select Product. For installation of Backup Application software, refer to the software vendors software application user guide supplied with the software or on the software vendors web.
Front LED Indicators
Figure 5
Light Emitting Diodes (LED)
Drive State
READY LED (Green left)
ACTIVITY LED (Green)
CLEAN LED (Amber)
FAULT LED (Amber right)
LED-test. The LEDs are turned ON one-by-one. Power-On Self-Test starts in parallel with the LED-test. Cartridge not loaded. Cartridge loaded, no activity Cartridge loaded, activity Cleaning Cartridge loading or unloading Unrecoverable drive failure Over temperature Media Error (wrong, write protected or harmed media)
OFF ON ON OFF OFF ON / OFF OFF OFF
OFF OFF Flashing Flashing Flashing OFF OFF Flashing
ON / OFF ON / OFF ON / OFF ON ON / OFF ON / OFF ON / OFF ON / OFF
OFF OFF OFF OFF OFF Flashing ON Flashing
Table 2
Front LED behavior during normal operation
Media and Capacities
To achieve and maintain the maximum quality of your Tandberg Data tape drive, we recommend using Tandberg Data media.
Drive Model Tandberg 220LTO Tandberg 420LTO LTO1, 2, 3 Media Name Tape Length 609 m 609 m 609 m Capacity (Native) 100 GByte 200 GByte 100 GByte Ordering no. 26 31
LTO Ultrium Generation 1 (Native format) LTO Ultrium Generation 2 (Native format) LTO Ultrium Generation 1 (Read/Write compatible) Cleaning Cartridge for LTO1, LTO2 and LTO3
Table 3
Media alternatives
External Tabletop Enclosure
ON/OFF Switch Cooling Fan SCSI_ID Switch
SCSI Interface Connectors
Figure 6
External tabletop enclosure, rear side
Power Requirements
Tandberg 220/420LTO in external tabletop enclosure: AC Input: 100 VAC / 0.6 A or 240 VAC / 0.3 A, 50-60 Hz Tandberg 220/420LTO as standalone: DC Input (typical operation): 5 VDC / 2.1 A, 12 VDC / 0.6 A
Heat Dissipation
Tandberg 220/420LTO as standalone: Operating: 18 W Sleep mode with cartridge inserted: 9 W 6
Total customer satisfaction is of the utmost importance to Tandberg Data.
We guarantee that this product left our premises defect free. If you are not satisfied with the quality of this product, please contact your distributor or the nearest Tandberg Data office to have the problem solved! For more documentation and information, please see our website www.tandberg.com.
Tandberg Data
International headquarter
Tandberg Data ASA, Kjelssveien 161, Oslo, P.O. Box 134 Kjelss, N-0411 Oslo, Norway. Tel: +90. Fax: +50. www.tandberg.com
Worldwide subsidiaries
Tandberg Data Corp., 2108 55th Street, Boulder, CO 80301, USA Tel. Toll Free: +1 800-392-2983. Tel. Local: (303) 442-4333 Tandberg Data GmbH, Feldstrasse 81, D-44141 Dortmund, Germany. Tel: +5436 0. Fax: +5436 111. Tandberg Data S.A.S., 16/18 Ave. Morane-Saulnier, F-78941 Vlizy Cedex, France. Tel: +01 01/00800-82632374. Fax: +(for technical support: 00800-07867243). Tandberg Data (Asia) Pte. Ltd, 20 Bendemeer Road, #04-05 Cyberhub, Singapore 339914, Tel: +0786. Fax: +0787. Tandberg Data (Japan) Inc., Eitaibashi Eco-Piazza Bldg. 8th floor 29-13, Shinkawa 1-chome, Chuo-ku Tokyo 104-033, Japan Tel: +5566 2871. Fax: +5566 2875. Tandberg Data Ltd., Bloxham Mill Business Centre, Barford Road, Bloxham, Banbury, Oxfordshire, OX15 4FF, United Kingdom Tel: +44 (0) 8450706916.
Specifications subject to change without notice. All trademarks are the property of their respective owners. 2006 Tandberg Data ASA. All Rights reserved. Part No. 433261-04. February 2006.
Tandberg 220/420LTO
Half Height LTO1 and LTO2 Tape Drive
Quick Installation Guide
Revision 4 February 2006
Mechanical Installation
For mechanical mounting specifications, please refer to Figure 1. Allowed mounting position is either horizontal with the indicator LEDs to the right, or vertical with the LEDs up. The drive occupies a half-size 5.25-inch slot with standard holes for mounting screws on both sides of the drive chassis and at the bottom of the drive.
Figure 1
Important! Mounting screw requirements
Mounting specifications
Only M3 (metric) screws must be used for mounting the drive Maximum permitted screw penetration: 2.5 mm Minimum required screw penetration: 2.0 mm Screw torque, mounting screws: 0.5 Nm Screws are supplied with all the Tandberg 220/420LTO drive variants Bags with 4 screws and 4 SCSI ID jumpers are available (Ordering no. 65)
Do not use longer screws or higher screw torque than specified!
Figure 2
Allowed mounting orientations
SCSI Identification
Make sure that the drive unit has the proper SCSI-ID before it is connected to a computer system. Refer to manuals for host computer and application software to obtain the correct ID. For correct mounting of ID-jumpers at the rear of the drive, please refer to Figure 3 and Table 1. External drives have a thumb-wheel switch to set the SCSI-ID (see Figure 6).
Power Connector
Service Connector
SCSI Connector
Figure 3 The factory default drive number setting is SCSI ID = 2. If the drive has to be set up with a different unit number, the jumpers (on the Service Connector) have to be connected according to Table 1. Example: SCSI ID = 3
Drive connectors
SCSI ID=0 SCSI ID=1 SCSI ID=2 SCSI ID=3 SCSI ID=4 SCSI ID=5 SCSI ID=6 SCSI ID=7 SCSI ID=8 SCSI ID=9 SCSI ID=10 SCSI ID=11 SCSI ID=12 SCSI ID=13 SCSI ID=14 SCSI ID=15
Table 1 Service Connector jumper settings for SCSI ID (Dark = Jumper mounted) 3
SCSI Cable
Host SCSI-bus Internal Terminator Connector Last SCSI Device 10 cm
Figure 4
SCSI cable (Ordering no. 51) (Ordering no. 53) (Ordering no. 17) (Ordering no. 64)
Internal SCSI-LVD/SE-cable with 5 connectors Internal, removable SCSI-LVD/SE-terminator External, removable SCSI-LVD/SE-terminator External SCSI 68HD/VHDCI 320MBs-cable
Termination
The SCSI-bus cable must be terminated in both ends according to SCSI specifications. If the tape drive is the last device on the bus, the bus must be terminated within 10 cm of the tape drive connection. Tandberg 220/420LTO has a combined SCSI-LVD/SE interface embedded. The PC-98 Specification specifies that the termination of the SCSI-bus system is a part of the SCSI-cable and not a part of the SCSI-device. As a result, termination cannot be turned on or off directly on the tape drive itself. For internal devices, a SCSI-cable with an integrated terminator or a separate terminator applied to the end connector of the cable, 10 cm from the last device, must be used. External devices must be terminated with an external terminator on the last device on the SCSI-bus.
Software Installation
For Software Application support and software drivers, please see www.tandberg.com. Then select SUPPORT and Select Product. For installation of Backup Application software, refer to the software vendors software application user guide supplied with the software or on the software vendors web.
Front LED Indicators
Figure 5
Light Emitting Diodes (LED)
Drive State
READY LED (Green left)
ACTIVITY LED (Green)
CLEAN LED (Amber)
FAULT LED (Amber right)
LED-test. The LEDs are turned ON one-by-one. Power-On Self-Test starts in parallel with the LED-test. Cartridge not loaded. Cartridge loaded, no activity Cartridge loaded, activity Cleaning Cartridge loading or unloading Unrecoverable drive failure Over temperature Media Error (wrong, write protected or harmed media)
OFF ON ON OFF OFF ON / OFF OFF OFF
OFF OFF Flashing Flashing Flashing OFF OFF Flashing
ON / OFF ON / OFF ON / OFF ON ON / OFF ON / OFF ON / OFF ON / OFF
OFF OFF OFF OFF OFF Flashing ON Flashing
Table 2
Front LED behavior during normal operation
Media and Capacities
To achieve and maintain the maximum quality of your Tandberg Data tape drive, we recommend using Tandberg Data media.
Drive Model Tandberg 220LTO Tandberg 420LTO LTO1, 2, 3 LTO Ultrium Generation 2 (Native format) LTO Ultrium Generation 1 (Read/Write compatible) Cleaning Cartridge for LTO1, LTO2 and LTOm 609 m 200 GByte 100 GByte 31 Media Name Tape Length 609 m Capacity (Native) 100 GByte Ordering no. 30
LTO Ultrium Generation 1 (Native format)
Table 3
Media alternatives
External Tabletop Enclosure
ON/OFF Switch Cooling Fan SCSI_ID Switch
SCSI Interface Connectors
Figure 6
External tabletop enclosure, rear side
Power Requirements
Tandberg 220/420LTO in external tabletop enclosure: AC Input: 100 VAC / 0.6 A or 240 VAC / 0.3 A, 50-60 Hz Tandberg 220/420LTO as standalone: DC Input (typical operation): 5 VDC / 2.1 A, 12 VDC / 0.6 A
Heat Dissipation
Tandberg 220/420LTO as standalone: Operating: 18 W Sleep mode with cartridge inserted: 9 W 6
Total customer satisfaction is of the utmost importance to Tandberg Data.
We guarantee that this product left our premises defect free. If you are not satisfied with the quality of this product, please contact your distributor or the nearest Tandberg Data office to have the problem solved! For more documentation and information, please see our website www.tandberg.com.
Tandberg Data
International headquarter
Tandberg Data ASA, Kjelssveien 161, Oslo, P.O. Box 134 Kjelss, N-0411 Oslo, Norway. Tel: +90. Fax: +50. www.tandberg.com
Worldwide subsidiaries
Tandberg Data Corp., 13000 Gregg Street, Poway, CA 92064, U.S.A. Tel: 858-726-1800. Fax: 858-726-1801 Tandberg Data GmbH, Feldstrasse 81, D-44141 Dortmund, Germany. Tel: +5436 0. Fax: +5436 111. Tandberg Data S.A.S., 16/18 Ave. Morane-Saulnier, F-78941 Vlizy Cedex, France. Tel: +01 01/00800-82632374. Fax: +(for technical support: 00800-07867243). Tandberg Data (Asia) Pte. Ltd, 20 Bendemeer Road, #04-05 Cyberhub, Singapore 339914, Tel: +0786. Fax: +0787. Tandberg Data (Japan) Inc., Eitaibashi Eco-Piazza Bldg. 8th floor 29-13, Shinkawa 1-chome, Chuo-ku Tokyo 104-033, Japan Tel: +5566 2871. Fax: +5566 2875. Tandberg Data Ltd., Bloxham Mill Business Centre, Barford Road, Bloxham, Banbury, Oxfordshire, OX15 4FF, United Kingdom Tel: +44 (0) 8450706916.
Specifications subject to change without notice. All trademarks are the property of their respective owners. 2006 Tandberg Data ASA. All Rights reserved. Part No. 433261-04. February 2006.
Tags
Navigon 6310 Disk Shot GR20CB Siemens CX70 20U51 T 7720 62015-91600 250DX GR-051SSF CAN DMC-TS1 GR-DVX7 Satellite L505 Dect2188 TX8201 Bizhub 423 Roomba 570 PH 211 WJ-HD500 MCD795SW DCR-PC104E DSP-AX2 TH-42PY85PA IC-M31 CW600T DP43TF Olympus X-41 Satio U1I 3-300 RSP-1066 T 265 250 358-353690-2-3-16 PS CMX100III CDR880-00S Aktywnych TTR50-2006 32PF3321 LCD1760NX Handset 7510A Sd7581 WD-10155FB DAR482BLS BMW 520D AJM180 HD154UI Zoom-nikkor HVL-LBP 27WL46 SE-2008 LE-32S62B Review GR-DF420 Orbit V2 NV-HV51 D-LUX 5 PM635I FS750T2 BHM-612A 48230 4 LI 234XL XR-1900 TX32LE8FA V1 0 Gpsmile236 F1013J HR7774 Rotak 320 CDX-M770X Easyshare C663 SD110 Birchmeier Iris AVR-1706 Wildfire 30 ER-A310 Server 21PT1532-58 DSC-W350 P Coupe CS-XE12EKE X-25B LA40R71BD WM-EQ3 KDL-40EX709 KDC-4021 LT RTS EL-1750piii RC-971 WL-5430AP Biotec 30 FX-991MS CL-15K5MN KDL-19BX200 System I Watch B080 713BM Plus M6 TTL OT-802 50 ST 68002K-MN
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding
Sitemap
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101










