Reviews & Opinions
Independent and trusted. Read before buy Technoline BC-900!

Technoline BC-900


Bookmark
Technoline BC-900

Bookmark and Share

 

Technoline BC-900About Technoline BC-900
Here you can find all about Technoline BC-900 like manual and other informations. For example: review.

Technoline BC-900 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a Technoline BC-900 please write about it to help other people.
[ Report abuse or wrong photo | Share your Technoline BC-900 photo ]

 

 

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (Polish)
Technoline BC-900, size: 168 KB
Download (English)
Check if your language version is avaliable.
Most of manuals are avaliable in many languages.

 

Technoline BC-900

 

 

Video review

BC 900 battery test, Dec 21, 2009

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc0

BATTERY CHARGER

Instruction Manual
BEFORE USING OUR BATTERY CHARGER, READ IN DETAILS ALL INSTRUCTIONS CONTAINED IN THIS MANUAL. KEEP THIS MANUAL IN A SAFE PLACE AS YOU MAY NEED TO USE IT AT A LATER DATE. We draw the attention of all users of this device: please follow the safety and maintenance instructions which are part of this manual. Also read the caution markings on the charger, the manual, and the gift box.

INTRODUCTION:

Congratulations on purchasing this intelligent charging unit which enables definitely quick and optimum charging to AA and AAA rechargeable batteries. With charging, discharging, refreshing and capacity test functions as well as individual LCD displays for charging compartments; this charging unit is reliable, user-friendly and ideal for use in the home, office or on journey. The Charging unit

CAUTIONS:

1. The charger is restricted to charging NiCd and NiMH rechargeable batteries only. Never adopt this charger to other types of batteries such as alkaline, lithium, carbon zinc or other types that are not specified. The charging unit shall only be used only at normal indoor room conditions. Always follow the charging instructions for the rechargeable battery. Observe the recommended charging current of the rechargeable batteries. Never adopt a charging current higher than recommended in the charging process. Never use any power cable and transformer other than those originally supplied with the charging unit. The rechargeable batteries may become hot during charging (especially when high charging current is chosen). User shall take extra care when taking out the batteries after charging. Unplug the charging unit from the power source when not in use.

FEATURES:

The Charging unit Charging the rechargeable battery in various current value (200, 500 or 700 mA) Individual LCD display for compartments Charging both AA and AAA rechargeable batteries simultaneously
Overheat detection to protect rechargeable batteries from over-charging Minus delta voltage (-dV) detection for charge termination Damaged batteries detection Discharge mode (first discharging and then charging) to remove memory effect of rechargeable batteries Refreshing old rechargeable batteries by discharging/ charging cycles Test function to check the capacities of rechargeable batteries Different Charging/ Discharging functions can be launched independently and simultaneously to each rechargeable battery in the compartments Various display modes during charging/ discharging the charging current (in mA), time elapsed (in hh:mm), the terminal voltage (in V) and accumulated capacities (in mAh or Ah) INVENTORY OF CONTENTS 1. Charging unit 2. Transformer 3. Instruction Manual

FUNCTION KEYS:

There are three easy-to-use function keys and four number keys in the charging unit:

Compartment Number keys

CURRENT key

MODE key

DISPLAY

Compartment Number key

Press and release the Number key to select a particular battery compartment for charge modes and/or display mode adjustment.
The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will enable to toggle between the
Charge, Discharge, Test and Refresh mode. To change the operating mode for individual rechargeable battery, first press corresponding NUMBER key then press the MODE key.

DISPLAY key

Press and release to select the displays of the charging current (in mA), time elapsed (in hh:mm), the terminal voltage (in V) and accumulated capacities (in mAh or Ah) during the charging or discharging process. To change the display content of a particular rechargeable battery, first press corresponding NUMBER key then press the DISPLAY key.

Press to select the amount of current to be applied (within the first 8 seconds after batteries are inserted) in different operating modes (also see Start charging the rechargeable batteries below).
OPERATING MODES OF THE CHARGING UNIT
This powerful charging unit provides the following operating modes: a. Charge up the rechargeable battery (CHARGE) to charge up the rechargeable battery, automatically switch to trickle charge after rechargeable battery is full.
Discharge then charge up the rechargeable battery (DISCHARGE) to discharge the rechargeable battery then charge it for minimizing the memory effect. Refresh the rechargeable battery (REFRESH) to refresh the rechargeable battery to its maximum capacity by charging and discharging the rechargeable battery repeatedly until no further increase in the capacity is estimated. For old rechargeable batteries or those have not been used for a long times, refreshing may bring the rechargeable battery back to the optimum condition. Check the rechargeable battery capacity in mAh/ Ah (TEST)

CHARGE MODE

Charging at 200 mA is the default-operating mode of the charging unit. User may select a charging current of 200, 500 or 700 mA.
The estimated time of charging by various charging current is tabulated in Table 1. Table 1. Charging Time with various charging current Size of battery Battery Capacity Charging current selected (mA) Estimated charging time 700 ~3 hr 35 min AA 2500 mAh 500 ~5 hr 200 ~13 hr 700 ~60 min AAA 700 mAh 500 ~84 min 200 ~3 hr 30 min Note: User shall always observe the recommended maximum charging current of the rechargeable batteries. In general, 200 mA is a recommended charging current if rapid charging is not necessary. It is definitely safe and optimum to the rechargeable batteries. It may be necessary to charge and discharge the new rechargeable batteries for several times in the beginning before the optimum capacity of the rechargeable batteries can be obtained. And user is recommended to adopt once the "Refresh"
mode to the new rechargeable batteries in order to achieve the optimum battery capacity. When the transformer has been plugged to the power source, the version number of the charger (for example 29 ) will be displayed first. Then all the segments will light up momentarily and the null sign will be shown before batteries are placed. If damaged batteries are placed to the charging unit, the charger will also show null on LCD.

null displayed - No battery or damaged battery is placed to the charging unit
START CHARGING THE RECHARGEABLE BATTERIES
Once a rechargeable battery is inserted after the transformer has been plugged to the power source, the battery voltage (for example, 1.39V) will be displayed for 4 seconds. Then 200 mA Charge (default mode) will be shown on LCD for another 4 seconds, indicating that charging with 200 mA is to be started if no alternation in setting is made. Within this 8-second time from inserting the batteries the user may first select the operating mode by the MODE key. Then within 8 seconds from the last key pressing, user may select the charging/ discharging current by pressing the CURRENT key. Note: The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will enable to toggle between the Charge, Discharge, Test and Refresh mode. There is a 8-second time allowed for choosing further functions after each key pressing. If no more key is pressed, the LCD will blink one time to indicate the end of setting. Afterward, the current can no longer be changed during the process and the selected mode will be undergone.
After 8 seconds from no more keys pressing, the LCD will blink once to indicate the setting is confirmed and the selected mode activated

Charging current: 200 mA

Charge Mode
During charging, the different displays- Charging current (in mA), Time elapsed (in hh:mm), Terminal voltage (in V) and Accumulated capacities (in mAh or Ah) may be toggled and selected by pressing the DISPLAY key (refer Table 4). After the rechargeable battery is fully charged, Full sign will be shown on the display and the user may take out them at this time. Or if the rechargeable batteries are kept placing at the compartments, trickle charging will start. The trickle charging current is around 5% of the selected charging current to keep the rechargeable batteries being full.
Full sign is shown -The battery is fully charged Note : The current cannot be altered once the setting has been confirmed in the initial stage. This can avoid the user changing the current setting accidentally while doing setting on other rechargeable batteries. If one wants to change the applied current afterward, the rechargeable batteries must be taken out and inserted again. The maximum charging current of other rechargeable batteries are restricted by the current setting of the first inserted rechargeable battery. For instance, if the first inserted rechargeable battery is set to charge at 500 mA, then the second, third and fourth rechargeable batteries can be only set to charging at a maximum current of 500 mA.

Therefore, user is recommend to place the battery with the highest expected charging current at Compartment 1 first. To release the restriction of setting charging current, user shall take out all four rechargeable batteries from the charging unit. To change the operating mode during charging, one can press the MODE key (for selecting all rechargeable batteries) or NUMBER key then MODE key (for selecting individual rechargeable battery). 8 seconds after the last key press the LCD will blink one time to indicate the end of changing. When overheating condition occurs (over about 53C, usually due to too high a charging current selected), the charging will be stopped immediately and the display will shown 000 mA, the charging process will only resume once the temperature of the rechargeable batteries drops to a safe level. If overheat conditions continue to occur, the rechargeable batteries shall be taken out to cool down and then charged at a lower current.
When the battery is overheated the charging will ceases automatically. 000 mA will be displayed.
For new rechargeable battery it is recommended to charge it with 200 mA current for re-conditioning it from the long storage status.

DISCHARGE MODE

Discharge mode will first discharge the rechargeable battery then charge it. It is for removing the memory effects of rechargeable batteries. By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Discharge mode can be selected. (The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will enable to toggle between the Charge, Discharge, Test and Refresh mode.) Then user may also select different discharging current (see Table 2) by pressing the CURRENT key, within 8 seconds after inserting the batteries. (The display will blink once to indicate the setting has been confirmed and the current cannot be changed afterward.) Discharging current: 250 mA

Discharge Mode

Note: The discharging current is always set to be half of the coming charging current whose upper limit is 700 mA (see Table 2). Therefore user is recommended to carefully select the discharging current so that the charging current afterward will not be too high. Table 2. DISCHARGE MODE Current User-selected Discharging 100 mA current Thereafter Charging 200 mA current

250 mA 500 mA

350 mA 700 mA
Finally batteries will be fully charged in discharge mode and Full will be displayed. If user presses DISPLAY key at this time, "charge" icon instead of "discharge" icon will be displayed.

REFRESH MODE

Old rechargeable batteries and those have not been used for a long time require refreshing. This process will recover the optimum capacity of the rechargeable batteries. By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can be selected.
Refresh mode will start with discharging the rechargeable battery, then charging it. The repeated discharging and charging cycles will be launched until no further increase in the measured capacities is estimated.
Discharging current: 250 mA
Refresh mode (the battery is being discharged) Note: By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Refresh mode can be selected. (The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will enable to toggle between the Charge, Discharge, Test and Refresh mode.)
Then user may also select different discharging current by pressing the CURRENT key (see Note in Discharge mode and Table 2), within 8 seconds after inserting the batteries. (Or the display will blink once to indicate the end of setting and the current cannot be changed afterward.) It may take up to several days to finish the refreshing process, depending on the selected discharging current. The maximum refresh current is 350 mA.

TEST MODE

In Test mode the rechargeable batteries will first be fully charged and then discharged to determine the capacities. Finally, the rechargeable batteries are charged up again and the capacity in (mAh) of (Ah) will be estimated and shown after the discharging ends. By pressing the MODE key within 8 seconds after inserting the rechargeable batteries, the Test mode can be selected. (The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will enable to toggle between the Charge, Discharge, Test and Refresh mode.)

The Charging current in (mA)
Test mode Note: After selecting the Test mode, user may select different charging current in the Test mode by pressing the CURRENT key, within 8 seconds after the batteries are inserted. The afterward-discharging current will be half of the selected charging current (see Table 3). Table 3. TEST MODE Current User-selected Charging 200 mA current Thereafter Discharging 100 mA current

500 mA 250 mA

700 mA 350 mA
The maximum charging current is 700 mA. After the test mode is finished, the display will shift between the Full sign and the battery capacity (in mAh or Ah) automatically in 3-second intervals until the rechargeable batteries are removed. User can switch to other displays by pressing the DISPLAY key.
Battery capacity displayed in (mAh) as the checking is finished in Test mode.

TRICKLE CHARGING

After the rechargeable battery is fully charged in any of the operating modes, the charger will give a small amount of current to the rechargeable batteries to maintain the fully charged level. This mode is automatically launched after rechargeable batteries are fully charged and kept at the charging unit. The signal Full will be displayed on the LCD.

DISPLAY MODE INFORMATION

User can use different display modes to monitor the rechargeable battery condition during the different operations (see below figure and Table 4 to 7). Different display modes are exhibited: Charging current, Time, Voltage and Capacity
Different operating modes
Table 4. Various displays in Charge Mode Various displays (toggled by pressing DISPLAY key) Stage in Charge Capacity mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) During charging Full stage Instantaneous Battery voltage Charging current Trickle charging current Charging time elapsed Accumulated capacity
Table 5. Various displays in Discharge Mode Various displays (toggled by pressing DISPLAY key) Stage in Capacity Discharge mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) During Discharging Discharging time Capacity during discharging current elapsed discharging Instantaneous During charging Battery voltage Charging current Charging time Accumulated elapsed capacity Trickle charging Full stage current
Table 6. Various displays in Refresh Mode Various displays (toggled by pressing DISPLAY key) Stage in Capacity Refresh mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) During Instantaneous Discharging Discharging time Capacity during discharging Battery voltage current elapsed discharging processes Capacity During charging Instantaneous Charging time determined in Charging current processes Battery voltage elapsed last time discharging Maximum battery capacity Instantaneous Trickle charging Elapsed time of Full stage determined in Battery voltage current last discharging discharging

Table 7. Various displays in Test Mode Various displays (toggled by pressing DISPLAY key) Stage in Test Capacity mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) Charging time During charging Charging current --- mAh elapsed During Discharging Discharging time --- mAh discharging current elapsed Capacity of the Instantaneous During 2nd 2nd charging battery Battery voltage Charging current charging time elapsed determined in discharging Capacity of the Trickle charging Discharging time battery Full stage current elapsed determined in discharging Note: *The timer will be resumed and counted from 00:00 again after the time elapsed is longer than 20 hours. (For example, 1:45 will be shown after the battery has been refreshed for 21 hr and 45 min.)
In case the power source is shortly interrupted or terminated when the charger is being operated, the operational mode will automatically be set to Charge mode at 200 mA to charge up the battery once the power source is back to normal, regardless the operating mode (Charge, Discharge, Refresh or Test) which has been selected by user before.

CARE AND MAINTENANCE:

Extreme temperatures, vibration and shock should be avoided as these may cause damage to the unit When cleaning the displays and casings, use a soft damp cloth only. Do not wet the exposed metal part of the charging unit. Do not use solvents or scouring agents as they may mark the LCD and casing. Do not spill water to the charging unit. Do not make any repair attempts to the units. Return it to its original point of purchase for repair by a qualified engineer. Opening and tampering with the units may invalidate its guarantee. Do not expose the unit to extreme and sudden temperature changes, this may lead to damage to the electronic parts in the unit.

SPECIFICATIONS:

Input voltage for AC/DC adapter Charging current range Max charging capacity (capacity of rechargeable batteries) Dimensions (L x H x W) of Charging unit : : : : 100-240 VAC 200 mA - 700 mA 3000 mAh 75 x 130 x 40 mm

LIABILITY DISCLAIMER:

The manufacturer and supplier cannot accept any responsibility for any improper or incorrect use and any consequences occur. Any performance of repairs or alternations by someone other than the original supplier will invalidate the warranty. This product is only designed to be used by people who have read and understood this instruction manual. The specifications of this product may change without prior notice. This product is not a toy. Keep out of the reach of children. No part of this manual may be reproduced without written consent of the manufacturer.

CAUTION - SAFETY INSTRUCTIONS :
Attention of users is drawn to the following important safety instructions: As stated in the manual above , only use NiCd or NiMH rechargeable batteries. Indoor use only, do not expose to humidity. Do not place in water or submit to rain and/or snow. Do not store or use near by an extreme heat. Keep batteries away from the fire. Do not use any accessories not supplied with the charger. Especially, never use any power cable and transformer other than those originally supplied with the charging unit. Disconnect the AC/DC when not in use Do not operate the charger if it has received a blow or has been subject to any damage. Do not use the Battery charger for other purposes than the Only one originally forecast Do not open or/and disassemble the charger: such handling may result in a risk of electric shock or fire.

 

Tags

MT-01 RQ-S80 Urc-2585 Actifry CI-5100T MAV5920AGW KDE-P32hv2 CPC-112 HF3463 DW511 68-35 Explorer-2006 LN52A850 KDC-7090R SCH-I830 6210701X61 F1 4 4124 CH 43P8341 Jungle Beat BM325 37LC51 DXZ435 Mainboard AR-7084GB 3 0 Roland S-10 CPX980 KDC-W531 HDT8010 12 JV-90 SC-HT535 GTA 4100 KDC-W312 MIX-R1U Calculator HRT 8010 NW-S203F 29PT8508 Singer 241 DK172 DN-C615 Express HD DR-M10s-dr-m10 KX-TD816NE PMA-510AE Se Date Dista T500 TL-WN310G RCM126 DSC-F717 Software W61 AF-IR ZMC19MG Alesis DM5 Firefly Kids Becker Z102 Syndicate Wars QG-HS805 ART FXR HS06THB D RS-505 DE Luxe 11-5CVT92meja Cusut Photo EX3 GR-AX720 TT-M1 DXZ935 Roland JS-5 Mc1602 Blackberry 6700 W2242PM-SS 700 M DRW-500 Printer AUB200 Casio 4317 4X4-2005 Vitamin CTK-900 U8120 CDP-CX270 VGN-NS21s S Poster Back K-SC 150 Vega 252 BOX 7240 P4P8x SE Pocket PC CLD-990 Antenna 15065D TX-21AP1C Review Emx212S Master 100 88730 CE-200 MZ-R500 SCH-V740

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 