Vaillant Combi-heater VCW
|
|
Bookmark Vaillant Combi-heater VCW |
Here you can find all about Vaillant Combi-heater VCW like manual and other informations. For example: review.
Vaillant Combi-heater VCW manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a Vaillant Combi-heater VCW please write about it to help other people. [ Report abuse or wrong photo | Share your Vaillant Combi-heater VCW photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)Vaillant Combi-heater VCW, size: 714 KB |
Vaillant Combi-heater VCW
User reviews and opinions
| lawfinger |
10:43am on Sunday, September 5th, 2010 ![]() |
| I bought this product, it looked great on the show. What I found after 4 uses is that blender blade no longer spins due to the plastic housing. | |
| CC-RIDER |
7:08am on Tuesday, August 17th, 2010 ![]() |
| I purchased this food processor in Feb 2010 - it appears to be a well made machine, and according to the booklet, will do all sorts of tricks. | |
| pchretien |
9:26am on Monday, July 5th, 2010 ![]() |
| Beware of missing parts I bought this product about two weeks ago and when i received it i opened the box to find out that the battery cover was missi... 3-in-1 Media Remote (PS3) I Do not recommend this at all. Its cheaply made and has a horrible feel to it. if you going to buy a PS3 remote. Failure - a comprehensive review This ones like a boomerang and heading straight back to where it came from! Rubbish! Avoid like the Plague Hoew can this be called a remote control or media remote? | |
| jeditdog |
8:34am on Thursday, April 15th, 2010 ![]() |
| I bought this Emeril 3 in 1 food processor for myself. Only made 1 milkshake in the blender. My daughter from Michigan came to visit. This is agreat product. I use it 3-4 times a week! | |
Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.
Documents

Vaillant Training/Logical Fault Finding Guide for all COMBlcompact and THERMOcompact models
~ Vaillant
HEATING,CONTROLS,HOT WATER.
"
tWJVaillanl
HEATING,CONTROLS, OTWATER. H
Contents
Guidance Notes
IICD l'
.".
Room Sealed Fan Flued Models (RSF) COMBlcompact VCW 242E, 282E THERMOcompact VC112E, 142E, 182E, 242E, 282E
Balanced Flue & Open Flue Models COMBlcompact VCW221, 240, 280 THERMOcompact VC110, 180, 240, 221.
tJ Vaillant
Guidance Notes (should be read before using this fault finding guide)
1. Check you are using correct guide for your appliance. See index and check model number. 2.Always start at the beginning of guide and work through one step at a time. 3.AII guides deal with central heating (C/htg) first, then hot water (D.HW.) Do the same when following guides. 4. When checking 240v AC mains voltage use terminal 1 on appliance terminal strip as the neutral test point. 6.ln order to use this fault finding guide ensure that the operating mode of circulating pump is set to operating mode (I) (selector plug adjacent to appliance terminal strip makes electrical connection to contact one) see diagram. T
0Gro GroG
5. When checking D.C. voltage use terminal 9 on appliance terminal strip as the negative test point. (All D.C. voltages are low voltage).
7. Note that illustrations and pictures are shown only once and are not duplicated again in this guide. Each illustration/picture has been given a reference number.
FRONT CONTROL PANEL Key 1. Yellow neon indicating power to operator. 2. Green neon indicating operation of Diaphragm pump. As voltage decreases to diaphragm pump so neon loses luminosity. 3. 0.16 amp anti surge fuse. 4. Time delay adjustment (factory set 5 minutes, adjustable 1-12 minutes). 5. Fault suppression button (ignition lockout). 6. Indicating neon (lockout). 7. 2 x 2 amp fuses (L&N). 8. Variable potentiometer controlling central heating flow temperature only. 9. Red neon rocker switch for power on. 10. Central heating rocker switch (not fitted on VC appliances).
Note 1 It is law* that any work carried out on a gas appliance must be carried out by a competent person who is registered with CORGI (Council for Registered Gas Installers). Note 2 All work involving electricity must be carried out by a competent person who is responsible for electrical safety checks. *Gas Safety (Installations and Use) Regulations 1984 Gas Safety (Installations and Use) Amendment Regulation 1990
tJVaillanl
Room Sealed Fan Flued Models (RSF)
guidance note 6)
+ YES +
~. f.l
(c) Check appliance not in time delay (isolate power, wait 5 seconds and restore). (d) Check anti surge fuse (0.16 amp).
tiJVaillanl
HEATING, CONTROLS, OTWATER. H
Inoe. pU\pP run1
~NO"
(a) Check 240v AC across pump terminals T Pic10
(b) Check pump free to rotate and not stuck T Pic11 ~.
Go ill 4
and (b) are OK.- change
Check hydraulic operation OK ? 1. Hydraulic diverter valve moves left closes microswitch M2 (VCW only)
(a) Check appliance and system full, pressurised and vented of air. (b) Check servo valve is in C/htg position, return spring holds carn down (VCW only). T Pic 12
(c) Check for dirt, sludge, flux or inhibitorcausTng frothing in system affecting:1. Pump performance 2. Hydraulic diverter valve (VCW only) 3. Servo valve (VCW only) 4. Connecting tubes 5. Main heat exchanger 6. Differential valve
M3 OPEN
2. Differential valve opens. T Pic 14
Rear view
Go to 5
Does applianC1 ignition? T
(a) Check microswitchM2 (20v DC) is making contact and closed circuit(VCW only). T Pic 15
(d) Check combustion chamber seals. (e) Cneck air switcn"tubes kinked and Sl., top cover plate clear. T
(yellow neon glowing front control box) (b) Check fan pressure switch oper9tes (240v AC :from both sides of switch to neutral terminal 1) if not check C to F T Pic 16
(1) Check fan working correctly. If all above OK change fan
pressure switch.
(c) Check flue installation: - Joints correctly located - Flue not blocke( - Terminal position
Does burner light and remain alight?
N;B. For lockoat (Black button & Red Neon) problems when no flame is visible check A to F. T
~ YES ~ t
\)~rnenflame is visible prior to lockout checkFto H only (a). Check gas supply to appliance live and purged. (b). Check differential valve open (if no return to Q4). (c). Check20v DC across gas operator, if available but operator fails to open (audible click) change operator. T
(d). Check central heating' overheat thermostat and connection (should be closed circuit, if open change component). T b" Pic22
71 I~O~
I (a) Check standing and working gas pressure at appliance inlet. T Pic25 (c) Check voltage across diaphragm pump (approx 6v DC) withNTC disconnected. T Pic27
Go to 8
(b) Check diaphragm pump operating tubes and throttle jet clear.
T Pic26
(d) Check burner pressure settings low and high fire rate. T Pic 28
(e) Check and/or replace gas operator.
fjJ NO~
(a) TestNTC/Elebtronic board. Pull off NTC wire (from D.H.W. overheat) touch it on chassis, if burner goes off, change NTC. T Pic29 If burner stays on change electronic board. (The gas operator may be stuck open eg debris. This symptom is very unlikely but can be checked by pulling off the wire to operator. Ifburner remains alight then change operator).
(a) Check demand for hot water-tap open and supply pipes correct way round. (b) Check water section moves servo valve cam - if not check venturi/diaphragm of water section. (d) Check hy valve moves microswitch r open no eTec through switch).
Pic 30
CLOSED
(e) If D check gas
(c) Check microswitCh M3 (20v DC) is making contact and closed circuit. Pic31.
pressure at & burner pr' Pic 25 & Pic 28. (1) If water fl<
insufficient c
adequate cold water mainO, supply and/or blockage in water section or DHW
tiJ Vaillant
Balanced Flue and Open Flue Models
H' COMBlcompact THERMOcompact VCW221 , 240, 280 VC11 0, 180, 240, 221
Red Rocker switch - Set to ON position - Set to ON position (VCW only)
Heating Switch
Circulating Pump - Operating mode position one (I) (see guidance note 6)
First check central heating operation (All external controls on)
Can pilot light be lit and established? (a) Check gas supply to appliance live and purged. (b) Check pilot injector, burner and supply tubes. Pic33 (d) Check thermocouple and connections. Pic35
Go to 2
(e) Check central heating overheat thermostat and connections (should be closed circuit, if open change component). Refer to Pic 22 (f) If intermittent pilot outage occurs check flue integrity (balanced flue) ventilation or draughts (open flue).
I.'"
(c) Check piezo ignitor, leads and electrodes. Pic34
Does red neon glow in main switch?
(a) Check 240v AC across terminals 2 (L) and 1 (N) Refer to Pic 1. (b) Check 2 x 2 amp appliance fuses. Refer to Pic 2.
(c) Check 3 amp spur fuse. If fuses OK and power available but neon fails to light, replace front Mother Board.
Go to 3
Does pump run?
(a) Check 240v AC across pump terminals (if not check C to F). Refer to Pic 10. (b) Check pump free to rotate and not stuck - If A & B are OK change pump. Refer to Pic 11. (c) Check 240v AC available for external controls at terminal 3, if not change Mother Board. Refer to Pic 5.
(d) Check demand for heating - external controls on, and 240v AC back to terminal 4. (e) Check anti surge fuse (O.16amp). Refer to Pic 4. (f) Check safety isolating transformer 240v AC primary (black/grey) and approx. 17v AC secondary (brown/blue). Refer to Pic 9.
Go to 4
'"
tij Vaillant
Check hydraulic operation OK? 1. Hydraulic diverter valve moves left closes microswitch M2 (VCW only). Refer to Pic 13. or 2. Differential valve closes microswitch T M4 (VC's only) Pic36
NO"
(a) Check appliance and system full, pressurised and vented of air. (b) Check servo valve is in C/htg position, return spring holds cam down (VCW only). Refer to Pic 12. (c) Check differential valve and tubes. (d) Check for dirt, flux sludge or inhibitor in system causing frothing affecting :1. Pump performance. 2. Hydraulic diverter valve (VCWonly). 3. Servo valve (VCW only) 4. Connecting tubes. 5. Main heat exchanger. 6. Differential valve.
Vaillanl
Does burner light?
Go to 6
(a) Check variable potentiometer (boiler stat) setting on maximum. (b) Check appliance not in time delay (isolate power wait 5 seconds and restore). (c) Check Domestic Hot Water overheat thermostat (VCW only) - pull off bottom white wire, if burner lights Replace DHW overheat. Refer to Pic 7. (d) Check NTC - (pull wire off NTC sensor, if burner lights change NTC. Refer to Pic 8. (e) Check operation and adjustment of microswitch M2 20v DC (VCW only). Refer to Pic 15. (f) Check differential valve closes microswitch M4 20v DC (VC only). T Pie3?
(h) Check for continuity through gas section microswitch M5 (20vDC) T Pic38
(i) Check for continuity through main heat exchanger overheat thermostat. T Pic39
(9) Check 20v DC across gas operator, if available but operator fails to open (audible click) change operator. Refer to Pic 21
0) Check small p.c.b. bridge located bottom rear of Mother Board. T
Does burner modulate up to high
fire rate after approx 5 seconds?
I~O"
, YES ,
Go to 7
(a) Check standing and working gas pressure at appliance inlet. Refer to Pic 25. (b) Check diaphragm pump operating tubes and throttle jet clear. Refer to Pic 26. (c) Check voltage across
diaphragm pump (approx 6v DC) (NTC disconnected Refer to Pic 27. (d) Check burner pressure settings low and high fire rate. Refer to Pic 28. (e) Check and/or replace gas operator.
tiJVaillant
fDoes appliance modulate down to low fire (ignition rate) and go off? To test Put appliance thermostat to no. 6, fire appliance for central heating. Burner should now modulate down and shut off at approx 60C (see temperature gauge).
(a) Test NTC/Electronic board. Pull off NTC wire (from DHW overheat) and touch it on chassis, if burner goes off change NTC. Refer to Pic 29 If burner stays on change electronic board.
(The gas operator may be stuck open e.g. debris. This symptom is very unlikely but can be checked by pulling off the wire to the operator. If burner remains alight then change operator).
If COMBlcompact VCW Go to 8
If THERMOcompact End of job
For VCW only - is D.HW operation OK?
(a) Check demand for hot water - tap open and supply pipes correct way round. (b) Check water section moves servo valve cam - if not check venturi/diaphragm of water section. Refer to Pic3(). (c) Check microswitch M3 (20v DC). Refer to Pic 31. (d) Check hydraulic diverter valve moves right opening microswitch M1 (with M1 open no electrical continuity
through switch). Refer to Pic 32. (e) If DHW not hot enough check gas supply working pressure at appliance inlet & burner pressure. Refer to Pic 25 & Pic 28. (f) If water flow rate insufficient check. for adequate cold water main supply and/or blockage in water section or DHW heat exchanger. End of job.
End of job
Head Office and Southern Region Vaillant imited, aillantHouse, L V Medway CityEstate, TridentClose, Rochester, KentME24EZ Reception Phone SalesPhone SalesFax Service Freephone ServiceFax Technical AdvicePhone Technical AdviceFax TrainingPhone
0634 292370
Vaillant imited, L AreaTrainingCentre LittletonHouse, shfordRoad, A Ashford,Middlesex TW151UU Service Freephone
WesternRegion Vaillant Limited, Dunster Road, Chelmsley Wood, Birmingham377UU B Sales Phone 0217883366 Sales Fax 318076 F Service reephone
Vaillant imited, nit2, L U Great estern W Business Park, Armstrong Way,Yate,BristolBS175NG SalesPhone 0454321736 SalesFax 0454321622 Service Freephone 0800318076
'., NorthernRegion Vaillant Limited, Vaillant Building, Euroway Trading state, E Wharfedale Road, Bradford, Yorkshire 6SR West BD4 Sales Phone Sales Fax Service reephone F 0274 651096~ 0800318076
Vaillant Limited, Block 13,Unit3, Whiteside Industrial Estate, Factory oad, R Bathgate, Lothian West EH48 2RX
SalesPhone
0506635522
Sales Fax Service reephone F
2nd edition February'94
0800 318076
Designed and Produced by IMPACT Image Management 0622 721144
Vaillant cannol accept responsibility for damage as a resull 01non-observance 01this Fault Finding Guide. Subject to alteration. (2194).
HEATING,CONTROLS.HOT WATER.
Tags
E-MU 404 Travelpilot 100 KX-TG1070SP CCD-TRV26E R08 AF LX-300 DSC-T50 VPL-EX50 S5620 Lexmark 2200 ICD-ST10 Keyboard CW-75 Doro 620 TX-88 Temporis 700 2491D300A A-973 661 A S6420 98240 SD1 MP950 12 5X HI-406BT S661fxms 2300N BZ28300 GR-332SFA Aspen Optio M30 MX6441 42LC7R Halion Rebel XTI Micro Star MS-202W WS-320M AD1079 SC-PM08 EOB50000X Server A-Z360 9000ED Uk KD-S9R JR-S300 Mkii V2 0 BTA II Flash HT-C460 Review SRS-Z500PC Dynax 3 AS09XLN VN-3600 KX-FM330 Riva Plus H 4200 Coffre CT-770 HQ8240 18 DV6710 Hdmi Security 2010 CE1113FL-S Inforad K1 EWT9120W 3 0 Sportcity 125 Chronograph MAX-A66 EMP-1715 CDX-L480 Monitor Spanish Toothbrush VTX 1000 CVP-109-107-105-700 Scaleo M KA226 AL1917 42PC3D-UD Black DCR-HC40E Nanoverb DN-S1000 Reverb AMP P4V800-X Automation Kala 200 ERE3000 HT-TXQ120 150 Trio DMR-EH59 TG-UV2 MRF-100 440 QE G 1230 Travelmate 6410 ERG29750 VAD-WG
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding