Reviews & Opinions
Independent and trusted. Read before buy White-rodgers Heat Pump Thermostat 1F82-261!

White-rodgers Heat Pump Thermostat 1F82-261

Manual

Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Manual - 1 page  Manual - 2 page  Manual - 3 page 

Download (English)
White-rodgers Heat Pump Thermostat 1F82-261, size: 157 KB
Instruction: After click Download and complete offer, you will get access to list of direct links to websites where you can download this manual.

About

White-rodgers Heat Pump Thermostat 1F82-261About White-rodgers Heat Pump Thermostat 1F82-261
Here you can find all about White-rodgers Heat Pump Thermostat 1F82-261 like manual and other informations. For example: review.

White-rodgers Heat Pump Thermostat 1F82-261 manual (user guide) is ready to download for free.

On the bottom of page users can write a review. If you own a White-rodgers Heat Pump Thermostat 1F82-261 please write about it to help other people.

 

[ Report abuse or wrong photo | Share your White-rodgers Heat Pump Thermostat 1F82-261 photo ]

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

Comments to date: 1. Page 1 of 1. Average Rating:
hakujouryu 11:03am on Friday, March 12th, 2010 
Works as advertized. It cools down my 16x12 bedroom with a 12 foot ceiling fast. It keeps the room temperature right where I set it. I have this unit in and up stairs T.V.

Comments posted on www.ps2netdrivers.net are solely the views and opinions of the people posting them and do not necessarily reflect the views or opinions of us.

 

Documents

doc0

White-Rodgers

80 Series

Heat Pump Thermostats

5/1/1 Day Programmable or Non-Programmable Hardwired

Heat Pump

ed Enhanc d e Light y Displa

ACCURACY

OPTIMUM COMFORT AND PERFORMANCE

1F82-261

5/1/1 Day Programmable

1F89-211

Non-Programmable

Programmable

Changing the World of Heat Pump Thermostats for the Better.
Weve improved the best-selling digital thermostat with new styling and enhanced home comfort features, specially designed for heat pump applications. It now offers more control, more convenience and more value than the competition. And its backed with the reputation of White-Rodgers pioneers in home comfort since 1937.
More Accuracy and Control. If youre in the process of upgrading a multi-stage, heat pump or single stage system, dont forget the brain for your new systemyour thermostat. Our White-Rodgers 80 Series can maintain a set temperature to within one degree. Plus, theres a permanent memory that saves all programs and settings during a power loss. Comfort and Convenience with Versatility. The programmable model delivers perfect comfort, as it automatically changes to the temperature you selected for wake-up, during the day, evening hours and while you sleep. You can also configure it with minimum and maximum temperature range for cooling or heating. The new 40% larger lighted display makes for clearer low-light viewing. Maximum Energy Savings. Program heating and cooling times to cut energy use, not comfort. You can save up to 33% in energy costs, depending on your homes location, climate and program selections. Now you can have it allenergy savings, with comfort and convenience! See the back to find out how this best-seller gives you more of what you want in a universal thermostat.

Job #: WRDG_115963

File Name: 115963_80SeriesHPmpSS_Rev.ai Printing & Finishing: 4/cProc-Offset Colors:

Revision: 06 Time: 4pm

Updates: jd10.18.06, jd10.20.06, jd11.29.06, jd12.01.06, kd12.07.06 BBpff12.15.06

Printout Size

This printout is for indicating color breaks only. Do not use for color matching. Do not measure for accuracy.
Size: 8.5" x 11"

CMYK DIE

Heat Pump 5/1/1 Day Programmable

Energy savings up to 33%

Hardwired
Comfort & Convenience Permanent program retention during power loss, no batteries needed Indefinite setpoint Hold or programmable timed Hold up to 8 hours (1F82-261) Air filter change indicator Simple menu to activate optional features Temporary temperature override until next program period (1F82-261) Soft-touch keypad Maintains room temperature differential within +/- 1 Display temperature recalibration (+/- 4)
Heat Pump Non-Programmable
5/1/1 Day Programmable or Non-Programmable
Programming (1F82-261) Choice of 5/1/1 day programmable or non-programmable 4 time and 4 temperature settings per program (heat & cool) Patented pre-programmed software simplifies time and temperature programming Display 60% larger LCD with improved contrast for easier reading Lighted display for easier low-light viewing
Performance Selectable Energy Management Recovery (1F82-261) Powerful next-generation microprocessor Meets ENERGY STAR specifications (1F82-261) Meets California Building Code, Title 24 (1F82-261) Fast (FA) or slow (SL) heating cycle anticipation B or O terminal (selectable) Compressor lockout protection (optional)

Terminal Designations

R C W2 Y G

24V Hot

24V Common
Auxiliary Compressor Blower/Fan Relay Heat (Stg. 1) Relay

Reversing Valve

Emergency Heat Relay

System Monitor

Dimensions
3.8"H x 6.1"W x 1.1"D

Thermal Specifications

Setpoint Temperature Range: 45 to 90F (7 to 32C) Rated Differential: 0.6 to 1.6F with adjustable anticipation Operating Ambient Temperature: 32 to 105F (0 to 40C) Operating Humidity Range: 90% non-condensing maximum Shipping Temperature Range: -4 to 150F (-20 to 65C)

Accessories

Wall Plate F61-2500 (7.6"W x 4.8"H) Thermostat Guard F29-0231
(For additional guard options refer to White-Rodgers catalog)
Electrical Specifications
Rating 20 to 30 VAC, 50/60 Hz or DC 0.05 to 1.2 Amps (load per terminal) 1.5 Amps maximum load (all terminals combined) Standard Systems Heat Pump2 stage heat, 1 stage cool Single stage heat pump
For Additional Information
Visit www.white-rodgers.com
Stages Heat/Cool by System
Single Multi- Heat Stage Stage Pump

2/1 2/1

Programs

Program Options

5+1+1

Model Number

1F82-261 1F89-211

Applications

Gas/Oil/ 3 Wire Millivolt Thermostat Auto Power Changeover Electric Zone Compatible Valve Source*
Selectable Performance Features

Program Override

Comfort & Convenience Features
Memory Diplay Alkaline Energy Furnace Lockout Back-up Warranty Management Programmable Energy Size Battery Life Lighted Cool Ignition P-Permanent (Years) Display Savings Fan Star (sq. in.) (Years) Recovery Module Reset B-Battery

1.8 1.8 2+ 2+ P P 1 1

* H = Hardwire (Requires Common)
St. Louis, Missouri Markham, Ontario 314-553-3600 905-201-4701 www.white-rodgers.com
The Emerson logo is a trademark and a service mark of Emerson Electric Co.

WR-3583-1

doc1

1F82-261
Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Your new 5-Day/1-Day/1-Day Digital Thermostat uses the technology of a solid-state microcomputer to provide precise time/ temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs. Features: Separate 5-day (weekday) and 1-day/1-day (Saturday/Sunday) programming with four separate time/temperature periods per day Simultaneous heat and cool program storage Preprogrammed temperature control Optional battery back-up for AC power loss LCD continuously displays set point, and alternately displays time and room temperature Continuous Backlit display option Temperature override until next program period Manual program override (HOLD temperature) Temporary HOLD F/C convertibility Temperature range 45 to 90F R, C, Y, W2, G, O/B, E, and L terminals for single or twotransformer systems

PRECAUTIONS

This thermostat is intended for use with a low voltage NEC Class II system. Do not use this thermostat with a line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction. ! CAUTION CAUTION To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete. ! WARNING Do not use on circuits exceeding specified voltage. Higher voltage will damage control and could cause shock or fire hazard. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage. Thermostat installation and all components of the system shall conform to Class II (current limited) circuits per the NEC code. Failure to do so could cause a fire hazard.

SPECIFICATIONS

ELECTRICAL DATA Electrical Rating: 20 to 30 VAC 50/60 Hz. or D.C. 0.05 to 1.0 Amps (Load per terminal) 1.5 Amps Maximum Total Load (All terminals combined) THERMAL DATA Setpoint Temperature Range: 45F to 90F (7C to 32C) Operating Ambient Temperature Range: 32F to 105F Operating Humidity Range: 0 to 90% RH (non-condensing) Shipping Temperature Range: -4F to 149F APPLICATIONS For use with the following Class II systems: Standard heat pump systems with electric, gas or oil Aux heat with 24VAC Hot and Common available Single-stage heat pump systems with no Aux heat with 24VAC Hot and Common available DO NOT USE WITH: Millivolt systems Systems exceeding 30 VAC and 1.5 amps 3-wire zoned hydronic heating systems

PART NO. 37-6175E

www.white-rodgers.com

Replaces 37-6175D 0811

INSTALLATION

REMOVE OLD THERMOSTAT

1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected. 2. Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly. 3. Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat. 4. Disconnect the wires from old thermostat one at a time. DO NOT LET WIRES FALL BACK INTO THE WALL. 5. Install new thermostat using the following procedures.
Optional (2) "AA" batteries Screw anchors

O/B switch

ATTENTION!
This product does not contain mercury. However, this product may replace a unit which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take up the spilled mercury and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must not be discarded in household trash. When the unit this product is replacing is to be discarded, place in a suitable container. Refer to www.white-rodgers.com for location to send the product containing mercury.
Mounting hole Reset switch (below Fan switch) W904 Mounting Electric/Gas hole jumper
Figure 1. Thermostat Base AC power. Installed batteries will also allow programming prior to installation. For best results, use new premium brand batteries such as Duracell or Energizer.
ENERGY MANAGEMENT RECOVERY (EMR)

When the EMR feature is activated the thermostat's microcomputer calculates the time it will take to change the room temperature to the next heat or cool program setting. Then the thermostat will start the system before the next programmed period so that the desired temperature is reached at or near the beginning of the period (the thermostat calculates 15 minutes for every 1F temperature change). This minimizes the use of auxiliary stages during the transition period to reduce energy costs. For example: The thermostat is programmed to provide an overnight heating temperature of 66F, and during the next program period, beginning at 6:00 AM, the programmed temperature is 70F. With EMR activated, the thermostat will automatically start the heating system at 5:00 AM, so that the programmed temperature of 70F is reached by about 6:00 AM. If the overnight room temperature drops only to 68F, the thermostat will start the system at 5:30 to reach the programmed temperature of 70F at 6:00. The thermostat is shipped with the EMR feature active, which means that the thermostat will start the heating system before the beginning of the next program period. This feature provides better efficiency by allowing gradual temperature changes using only the first stage of heat. To deactivate the EMR function, see the Configuration menu on Page 5). The thermostat will then wait until the programmed time to start the system for a temperature change.
ATTACH THERMOSTAT BASE TO WALL
1. Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit. 2. Connect wires beneath terminal screws on base using appropriate wiring schematic (see figs. 2 through 4). 3. Place base over hole in wall and mark mounting hole locations on wall using base as a template. 4. Move base out of the way. Drill mounting holes. 5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase. 6. Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

ELECTRIC/GAS JUMPER (Fan Option)
Read the following information before clipping the nonelectric heat jumper. If you are unsure of your application, contact a qualified service person. If your emergency or auxiliary system will energize the blower, then jumper, W904, on the thermostat base must be cut (see fig. 1). If your emergency or auxiliary heat system requires that the thermostat energize the fan circuit, do not cut jumper W904.
O/B TERMINAL SWITCH SELECTION
The O/B switch on this thermostat is factory set to the O position. This will accommodate the majority of heat pump applications, which require the changeover relay to be energized in COOL. If the thermostat you are replacing or the heat pump being installed with this thermostat requires a B terminal, to energize the changeover relay in HEAT, the O/B switch must be moved to the B position. 2

OPTIONAL BATTERIES

With two "AA" batteries installed, your thermostat will maintain time and continuously display the temperature during a loss of

THERMOSTAT

O/B Y G W2 See Note ** E C SYSTEM MONITOR SWITCH L R

SYSTEM

Changeover Relay*

Compressor Contactor

Fan Relay

Aux Relay (Stage 2)

Emergency Relay
Hot 24 VAC 120 VAC Neutral TRANSFORMER (Class II Current Limited)
* Changeover Relay is energized in COOL when O/B switch is in the O position Changeover Relay is energized in HEAT when O/B switch is in the B position ** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
Figure 2. Typical wiring diagram for single transformer systems
If safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits.
O/B Y G W2 E C SYSTEM MONITOR SWITCH L R

CUT AND TAPE OFF!

HOT 120 VAC NEUTRAL 24 VAC
Changeover Relay* Compressor Contactor
See Note ** Emergency Relay Aux Relay (Stage 2)

Limit or Safety Switches

Hot 24 VAC 120 VAC Neutral
* Changeover Relay is energized in COOL when O/B switch is in the O position Changeover Relay is energized in HEAT when O/B switch is in the B position

TWO COMMONS MUST BE JUMPERED TOGETHER!
TRANSFORMER (Class II Current Limited)
** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency
Figure 3. Typical wiring diagram for two transformer systems with NO safety circuits
Polarity must be observed. If the HOT side of the second transformer is jumpered to the COMMON side of the first transformer a short will be made. Damage to equipment will occur when power is restored.

E See Note **

Fan Relay Aux Relay (Stage 2)

SYSTEM MONITOR SWITCH

24 VAC

120 VAC

Limit or Safety HOT Switches

NEUTRAL

24 VAC ACCESSORY RELAY N.O. CONTACT

COMMON

Auxiliary NOTE Heating Transformer The accessory relay scheme (Class II is required when safety Current Limited)
circuits exist in both systems. Limit or Safety Switches
TWO COMMONS MUST BE JUMPERED TOGETHER! * Changeover Relay is energized in COOL when O/B switch is in the O position Changeover Relay is energized in HEAT when O/B switch is in the B position ** Jumper required to use a single Aux Heat for both Second Stage Heat and Emergency

24 VAC 120 VAC

HOT NEUTRAL
Heat Pump Transformer (Class II Current Limited)
Figure 4. Typical wiring diagram for two transformer systems with safety circuits in BOTH systems
CHECK THERMOSTAT OPERATION
If at any time during testing your system does not operate properly, contact a qualified service person. Turn on power to the system.

Emergency System

EMER bypasses the Heat Pump to use the heat source wired to terminal E on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only. 1. Move SYSTEM switch to EMER position, EMER will flash on the display. to adjust the thermostat above room tempera2. Press ture. The Aux heating system will begin to operate. The Flame icon ( )will display flashing to indicate that the Aux system is operating. 3. Press to adjust the thermostat below room temperature. The Aux heating system should stop operating.

Fan Operation

If your system does not have a G terminal connection, skip to Heating System. 1. Move fan switch to ON position. The blower should begin to operate. 2. Move fan switch to AUTO position. The blower should stop immediately.

Heating System

1. Move SYSTEM switch to HEAT position. If the auxiliary heating system has a standing pilot, be sure to light it. 2. Press to adjust thermostat setting to 1 above room temperature. The Heat Pump system should begin to operate. However, if the Flame icon ( ) and Snowflake icon ( ) are flashing, the compressor lockout feature is operating (see Configuration menu, item 7). 3. Adjust temperature setting to 4 above room temperature. The auxiliary heat system should begin to operate and the Flame icon will be flashing. to adjust temperature setting below room tem4. Press perature. The heating system should stop operating.

Cooling System

! CAUTION CAUTION To prevent compressor and/or property damage, if the outdoor temperature is below 50F, DO NOT operate the cooling system. 1. Move SYSTEM switch to COOL position. to adjust thermostat setting below room tempera2. Press ture. The blower should come on immediately on high speed, followed by cold air circulation to adjust temperature setting above room tem3. Press perature. The cooling system should stop operating. ! CAUTION CAUTION Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been operational for at least 5 minutes.

OPERATION

Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base. To replace the cover, line up the cover with the base and press until the cover snaps onto the base.

THE THERMOSTAT BASE

Other than and , the following buttons and switches are located on the bottom of the thermostat cover (see fig. 5).
FAN TIME PRGM RUN HOLD ON Fltr AUTO OFF HEAT
The Thermostat Buttons and Switches
1 Raises temperature setting. 2 Lowers temperature setting. 3 TIME button. 4 PRGM (program) button. 5 RUN (program) button. 6 HOLD temperature button. 7 FAN switch (ON, AUTO). 8 SYSTEM switch (COOL, OFF, HEAT, EMER). 4

MO TU WE TH FR

SA SU MALF
Figure 5. Thermostat display, buttons, and switches

The Display

9 Indicates day of the week. 10 Indicates a malfunction with the system. 11 Flame icon ( ) is displayed when the SYSTEM switch is in the HEAT position. Flame icon ( ) is displayed flashing when 2nd-stage heat (Aux or Emergency) is energized. Snowflake icon ( ) is displayed (non-flashing) when the SYSTEM switch is in the COOL position. Snowflake and Flame are displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling too quickly. 12 EMER is displayed flashing when the system switch is in EMER position. 13 Alternately displays current time and temperature. 14 The word HOLD is displayed when the thermostat is in the HOLD mode. HOLD is displayed flashing when the thermostat is in a temporary HOLD Mode. 15 Displays currently programmed set temperature (this is blank when SYSTEM switch is in the OFF position). 16 Displays FLTR when the system has run for the programmed filter time period as a reminder to change or clean your air filter.

Press HOLD to change to the next menu item or press TIME to go backwards to the previous item in the menu. To exit the menu and return to the program operation, press RUN. If no keys are pressed within fifteen minutes, the thermostat will revert to normal operation. 1) Select Temporary Hold Time - The thermostat can hold any temperature you set it to for the amount of time you select on this option. Your choices are 0:00 to 8:00 hours in 15 minute increments. 0:00 disables the function Example: Using the Temporary Hold Function 1. You have selected 3:00 hours for the Temporary Hold time period. 2. With the thermostat set to Heat or Cool, press HOLD for five seconds (time will show 3:00 hours as a setting reminder). 3. HOLD on the display will blink. Release the HOLD button after the temporary hold time is displayed. or to set the temperature to your prefer4. Use ence. The thermostat will maintain this temperature setting for 3 hours with HOLD blinking to remind you it is in Temporary Hold. After 3 hours the thermostat will go back to the program temperature and HOLD will no longer blink or display. 2) Select FA or SL (Fast or Slow) Heat Pump stage Cycle Rate - The FA setting is used to produce shorter heating cycles. The SL setting produces a longer heating/cooling cycle. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under.75F and the SL setting cycles at approximately 1.2F. 3) Select FA or SL (Fast or Slow) Auxiliary or Emergency Cycle Rate - The FA setting is frequently used for gas, oil or electric heat. The SL setting produces a longer heating cycle. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under.6F and the SL setting cycles at approximately 1.F.

CONFIGURATION MENU

The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. Press RUN to make sure the thermostat is in the run program mode, then press PRGM and RUN at the same time to enter the configuration menu. The display will show the first item in the configuration menu. The configuration menu chart summarizes the configuration options. An explanation of each option follows.

Configuration Menu

Step Press Button(s)
PRGM and RUN HOLD* (SL) HOLD* HOLD* HOLD* HOLD* HOLD* HOLD* HOLD* HOLD* RUN EMER (FA) d-L (on) E (on) Filter (000) LOC (OFF) 0 HI (0) (F) FA (on)
Displayed (Factory Default)

HOLD (0:00)

to select:

COMMENTS

Select temporary Hold time Select FA or SL (Fast or Slow) pump cycle rate Select FA or SL (Fast or Slow) Auxiliary and Emergency Aux heating cycle rate Select display backlight OFF or ON Select Energy Management Recovery OFF or ON Select filter replacement run time Select Compressor lockout OFF or ON Select temperature display adjustment higher or lower Select temperature display to F or C Select fast second stage ON or OFF Returns to normal operation

0 to 8 hrs (in 15 minute increments) FA SL OFF OFF 0 to 1950 hours (in 50 hour increments) on 4 LO to 4 HI C OFF
* Press HOLD to advance to next item or TIME to move backwards to previous item 5
4) Select backlit display - The display backlight improves display contrast in low lighting conditions. Selecting backlight ON will keep the light on continuously. Selecting OFF will keep the light off. 5) Select Energy Management Recovery OFF or ON Energy Management Recovery (EMR) causes the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. 6) Select filter replacement run time - The thermostat will display FLTR after a set time of operation. This is a reminder to change or clean your air filter. This time can be set from 0 to 1950 hours in 50 hour increments. A selection of 000 will cancel this feature. When FLTR is displayed, you can clear it by pressing HOLD and RUN at the same time. This resets the timer and starts counting the hours until the next filter change. Contact your heat pump manufacturer for a specific replacement/maintenance interval. 7) Select Compressor Lockout LOC OFF or ON - Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling or heating cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs it will flash the Snowflake and Flame icons for about five minutes. 8) Select Temperature Display Adjustment 4 LO to 4 HI Allows you to adjust the room temperature display up to 4 higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat. The current or adjusted room temperature will be displayed on the right side of the display. 9) Select F or C Readout - Changes the display readout to Celsius or Fahrenheit as required. The current room temperature will be displayed on the right side of the display. 10) Select Fast second stage - In the RUN mode, if the temperature is manually raised by 3F ( 2C) or more above and the fast second stage room temperature using feature is enabled, FA on, the second stage will energize immediately. With FA off, the second stage will not energize until the setpoint temperature is 10F or more above room temperature.

SAMPLE Heating/Cooling Schedule Plan (Factory Program) WEEKDAYS (5 Day)

Period Start Time Temp

MANUAL OPERATION
HOLD TEMPERATURE With the SYSTEM switch set to HEAT or COOL, momentarily press HOLD button. HOLD will be displayed. Use or to adjust the temperature. The thermostat will hold the room temperature at the selected setting until you press RUN button to start program operation again. TEMPERATURE OVERRIDE Press or until the temperature you want is displayed. The thermostat will override current programming and keep the room temperature at the selected temperature until the next program period begins. Then the thermostat will automatically revert to the program. TEMPORARY HOLD TEMPERATURE The thermostat can hold any temperature within its range for the length of time selected in the configuration menu. See Configuration Menu section, step 1.
PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostats program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program. When heating (cooling) your building, program the temperatures to be cooler (warmer) when the building is vacant or during periods of low activity. During early morning hours, the need for cooling is usually minimal.

Planning Your Program

Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN button to begin running the factory preset program. If you want to change the preprogrammed times and temperatures, follow these steps. Determine the time periods and temperatures for your program. You must program four periods for each day. However, you may use the same heating and cooling temperatures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently (for example, you may select 5:00 AM and 70 as the weekday 1st period heating start time and temperature, and also choose 7:00 AM and 76 as the weekday 1st period cooling start time and temperature).
Heating/Cooling Schedule Plan WEEKDAYS (5 Day)

SATURDAY (1 Day)

Start Time Temp

SUNDAY (1 Day)

1ST HEAT 2ND 3RD 4TH 1ST COOL 2ND 3RD 4TH
6:00 AM 8:00 AM 5:00 PM 10:00 PM 6:00 AM 8:00 AM 5:00 PM 10:00 PM

70F 62F 70F 62F 78F 85F 78F 82F

6:00 AM 8:00 AM 5:00 PM

70F 62F 70F

70F HEAT COOL 62F 70F

1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH
10:00 PM 62F 6:00 AM 8:00 AM 5:00 PM 78F 85F 78F

10:00 PM 82F

Use the table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs.

Entering Your Program

Set Current Time and Day
1. Press TIME button once. The display will show the hour only. EXAMPLE:
2. Press and hold either or until you reach the correct hour and AM/PM designation (AM begins at midnight; PM begins at noon). 3. Press TIME once again. The display window will show the minutes only. EXAMPLE: 4. Press and hold either or until you reach the correct minutes. 5. Press TIME once again. The display will show the day of the week. 6. Press or until you reach the current day of the week. 7. Press RUN once. The display will show the correct time and room temperature alternately.
6. Repeat steps 3 and 4 to select the start time and heating temperature for the 2nd heating program period. 7. Repeat steps 3 through 5 for the 3rd and 4th heating program periods. 8. Press PRGM once. SA (indicating Saturday program) will appear in the display, along with the start time for the 1st heating period and the currently programmed temperature. 9. Repeat steps 3 through 7 to complete Saturday heating programming. 9. Press PRGM once to change to SU (Sunday) heating programming and repeat steps 3 through 7 to complete Sunday programming. 11.When you have completed entering your heating program, press RUN.

Enter Cooling Program

! CAUTION CAUTION If the outside temperature is below 50F, disconnect power to the cooling system before programming. Energizing the air conditioner compressor during cold weather may cause personal injury or property damage. 1. Move SYSTEM switch to COOL position. 2. Follow Enter Heating Program for entering your cooling program, using your selected cooling times and temperatures.

Enter Heating Program

1. Move the SYSTEM switch to HEAT. 2. Press PRGM once. MO TU WE TH FR (indicating weekday program) will appear in the display. Also displayed are the currently programmed start time for the 1st heating period and the currently programmed temperature (flashing).

CHECK YOUR PROGRAMMING

Follow these steps to check your thermostat programming one final time before beginning thermostat operation. 1. Move SYSTEM switch to HEAT position. 2. Press PRGM to view the 1st weekday heating period time and temperature. Each time you press PRGM, the next heating period time and temperature will be displayed in sequence for weekday, then Saturday and Sunday program periods (you may change any time or temperature during this procedure). 3. Press RUN. 4. Move SYSTEM switch to COOL position. 5. Repeat step 2 to check cooling program. 6. Move SYSTEM switch to HEAT or COOL and press RUN to begin program operation. NOTE: Batteries are not required to keep your programming or menu data. With two optional AA batteries installed, your thermostat will maintain time and continuously display the temperature during a loss of AC power. Installed batteries will also allow programming prior to installation.
YOUR THERMOSTAT IS NOW PROGRAMMED AND READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!

EXAMPLE:

This display window shows that for the 1st weekday period, the start time is 6:00 AM, and 68 is the programmed temperature (this example reflects factory preprogramming). or to change the displayed temperature to 3. Press your selected temperature for the 1st heating program period. 4. Press TIME once (the programmed time will flash). Press or until your selected time appears. The time will change in 15 minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode. 5. Press PRGM once. The currently programmed start time and setpoint temperature for the 2nd heating program period will appear.
LINE: HOMEOWNER HELP LINE: 1-800-284-2925
White-Rodgers is a division of Emerson Electric Co.
The Emerson logo is a trademark and a service mark of Emerson Electric Co.

TROUBLESHOOTING

Reset Operation If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the thermostat by pressing the reset switch (see Fig 1). If the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Symptom

Heat/No Fan No Heat/No Cool/No Fan (common problems)

Possible Cause

1. Blown fuse or tripped circuit breaker. 2. Furnace power switch to OFF. 3. Furnace blower compartment door or panel loose or not properly installed. 1. System Switch not set to Heat. 2. Loose connection to thermostat or system. 3. Heating System requires service or thermostat requires replacement.

Corrective Action

Replace fuse or reset breaker. Turn switch to ON. Replace door panel in proper position to engage safety interlock or door switch. Set System Switch to Heat and raise setpoint above room temperature. Verify thermostat and system wires are securely attached. Diagnostic: Set System Switch to Heat and raise the setpoint above room temperature. Within a five minutes the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the furnace manufacturer or a service person to verify the heating system is operating correctly. Set System Switch to Cool and lower setpoint below room temperature. Verify thermostat and system wires are securely attached. Same procedure as diagnostic for No Heat condition except set the thermostat to Cool and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock-out option is selected in the configuration menu (Item 7). Check each wire connection to verify they are not shorted or touching together. No bare wire should stick out from under terminal screws. Try resetting the thermostat as described below. If the condition persists, the manufacturer of your system or service person can instruct you on how to test the Heat/Cool system for correct operation. If the system operates correctly, replace the thermostat. Item 2 in the Configuration Menu is the adjustment that controls the cycle rate. If an acceptable cycle rate is not achieved using the FA (Fast) or SL (Slow) adjustment contact a local service person for additional suggestions. The cycle rate for cooling is fixed and can not be adjusted. Contact a local service person for suggestions. The thermometer can be adjusted +/- 4 degrees as listed in item 8 of the Configuration Menu. No other adjustment is possible. The thermostat will maintain its program in memory even with no power but the clock time will be incorrect when power is restored. See No Heat/No Cool/No Fan (common problems) above for items to check in the system. See Configuration Menu (Item 5). Check current clock and program settings including the AM or PM designations for each time period. If a voltage spike or static discharge occurs use the Reset Operation listed above. If a voltage spike or static discharge occurs use the Reset Operation listed above.

Heat No Heat

No Cool
1. System Switch not set to Cool. 2. Loose connection to thermostat or system. 3. Cooling System requires service or thermostat requires replacement.
Heat, Cool or Fan Runs Constantly.
1. Possible short in wiring. 2. Possible short in thermostat. 3. Possible short in Heat/Cool/Fan system. 4. Fan Switch set to Fan On.
Furnace Cycles Too Fast or Too Slow 1. The location of the thermostat and/or the size of the Heating System may be influencing the (narrow or wide temperature swing) cycle rate.
Cooling Cycles Too Fast or Too Slow 1. The location of the thermostat and/or the size of the Cooling System may be influencing the (narrow or wide temperature swing) cycle rate. Thermostat Setting and Thermometer 1. Thermostat thermometer setting requires adjustment. Disagree Clock Loses or Gains Time 1. Loss of power to thermostat.
1. EMR activated Heat or Cool Starts Early Thermostat Does Not Follow Program 1. AM or PM set incorrectly in program. 2. AM or PM set incorrectly on the clock. 3. Voltage spike or static discharge. Blank Display and/or Keypad Not Responding 1. Voltage Spike or Static Discharge.

 

Tags

Guitar 75 A 248CLT T 14 Sagem D70T KCA-420I-i-pod-space-interface Dvdr3600 58 GSM7352S Navteq NN4D Galya 2500 ZK25 10R AV-rekorder-pack-304 Spider-2003 DTH8677 6 5 MP450 Central CS4 SGH-I740 NAD 5425 FID 2020 Soundchart MP-42PX10 2200T SGH-C506 CMT-CP100 Sdec-1000 NW-S636F Juno-1 VT 300I KX-FPC165 Velo 8 VGN-UX280P Docucolor 8000 LG VF48 Motorola Aura B4403-5-B EU HVL-10NH DZ-HS903 Repeater SU-33W For MAC AJ-LT95 UT21006 Nokia 3650 IC-P2CT Bluetooth Ixus 75 FO-A660 Batterie T4X Charger PSR-11 Maxxum 9XI XD3500U EF3124 Pmnfp14A0 SRA-800 Review 5500N Server 9045N Juiced Gpsmap 420S TR-505 SB-50DX X163W Hongkong FP567S V2 FA-124 Pearl 9100 DVD-8621N C7660 Coupe-cabriolet SPA7650 W376G BF 562 UD2121 Siemens TK60 Dvdr77-17B SA-HT07 DVD-S54 Clp-150 4X4-2004 VMC1E HT-SL55 LH-T502SH IC-M3euro KU800 Suburban 1993 LCD1525M Hwreg1 Deville 1993 FT-757GX II EV7DVD 3 3 PPD01 U4-131 41842 KD-G110 Station Soprano Plus PA1000X

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 