XTA DP6I
|
|
Bookmark XTA DP6I |
About XTA DP6IHere you can find all about XTA DP6I like manual and other informations. For example: review.
XTA DP6I manual (user guide) is ready to download for free.
On the bottom of page users can write a review. If you own a XTA DP6I please write about it to help other people. [ Report abuse or wrong photo | Share your XTA DP6I photo ]
Manual
Preview of first few manual pages (at low quality). Check before download. Click to enlarge.
Download
(English)XTA DP6I, size: 2.1 MB |
Related manuals XTA DP6I Info Sheet |
XTA DP6I
User reviews and opinions
No opinions have been provided. Be the first and add a new opinion/review.
Documents

For the finest audio quality throughout any venue
2 input / 6 output audio installation controller 4 front panel memories/configurations Proven control interface Audiocore for fast, easy set-up Tamper-proof technology System panic mute Unit shadow facility to simplify complex systems and easily increase outputs The finest audio quality, as already specified by the worlds top recording studios, theatres and artists
The DP6i continues XTAs reputation for sound quality in a unit designed for the most demanding applications of the installed sound market, where audio quality and system control are critical. The unit features 2 inputs and 6 outputs. Both inputs have an 8 band parametric equaliser, base delay and gain control. All outputs feature crossover filters, 5 band parametric equaliser, high and low shelving filters, limiter and delay. Full metering is provided for inputs and outputs, with a mute button for instant system control in emergencies. For added tamper-proof security, the unit has a Safe switch internally selectable to disable all front panel controls, and the ability to separately disable just the panel memory recall switches. Up to 32 DP6i can be controlled from a single PC with XTAs proven AudioCore Windows control software, with the ability for further units to shadow those 32 ID numbers for an unlimited number of system outputs.
l AQUA, l Centro
Grays, Essex, UK l Boston Symphony Hall, USA l Bridge & Tunnel, Shoreditch, UK l Fly, New York, USA l Cherry Jam, Royal Oak, London, UK l Club One, Cork, Eire l l Coliseum, Halifax, UK l Empire, Brisbane, Australia l Espionage, Aberdeen, UK l l Heaven & Hell, Stockport, UK l Kelly's, Portrush, Northern Ireland l l Mahony Hall, Dublin City University, Eire l Marquee Restaurant/Club, Islington, UK l l Ministry, Aberdeen, UK l New Era, Hong Kong l Nightingale, Birmingham, UK l l Oceania, Milton Keynes, UK l Oyster Quay Bar, Poole, UK l l p60, Amstelveen, nr Amsterdam, Netherlands l Pantiles, Bagshot, Surrey, UK l l Plan B, Brixton, UK l Platinum Disco Lounge, Johor Baru, Malaysia l Roxy, New York, USA l l Soda Bar, Derby, UK l Sound Bar, Chicago, USA l Sound Factory, New York, USA l l SPIN, Miami, USA l Spirit, Dublin l
Hundreds of venues worldwide rely on XTA processing, including:
Tel:+44(0)Fax:+44(0)email: info@xta.co.uk www.xta.co.uk
LISTEN CAREFULLY
TOTAL CONTROL
AudioCore Windows control software gives the user instant and intuitive control over all the parameters of the DP6i. Click on any units function block and the parameters for that function are immediately available and adjustable. All parameters can be adjusted via mouse or keyboard, including the versatility now offered by wireless solutions setup the system from any area. AudioCore enables centralised control of up to 32 DP6i units. It offers the ability to quickly view, set or change configurations and or parameters on multiple units. Equalisation curves are accessible for each input and output, allowing precise equalisation adjustments to be made. Mute and solo functions ease system troubleshooting. Full memory support is provided allowing the system to be disconnected from the software and run in a simple MIDI or closed contact memory recall mode. The Output Control screen gives the user control over Highpass and Lowpass filters for both frequency and slope enabling speedy setting of the crossover function. All parametric Equalisers are controllable by direct curve dragging or normal mouse/keyboard control. In curve dragging both frequency and gain locking are available. The units have built in interfaces for RS232, RS485 and MIDI. The RS232 and MIDI inputs are relayed out of the RS485 bus allowing multiple units to be easily cascaded. A general purpose interface option is available, allowing remote memory switching and instant system changes for a venue with varied requirements at different times.
Specifications
Inputs: 2 electronically balancedu Impedance: > 10k ohms. CMRR : >65dB 50Hz - 10kHz. Outputs: 6 electronically balancedu Source Imp: < 60ohms Min. Load: 600ohm Max. Level: +20dBm into 600 ohm Frequency Resp.:+dB 20Hz-20kHz Dyn Range:>110dB 20Hz-20k unwtd Distortion:<.02%@1kHz,+18dBm Maximum Delay: 650 mS Min Step Size: 2.6 S Input Gain: +6dB to -40dB in 0.1dB steps Output Gain: +15dB to -40dB in 0.1dB steps and mute Parametric Equalisation 8 per Input / 5 Sections per Output Filter Gain: +15dB to -30dB in 0.1dB steps. Freq. Range: 20Hz - 20kHz, 1/36 octave steps. (368 positions) Filter Q / BW: 0.4 to 128 / 2.5 to 0.008 (Sections switched to shelving response) Low frequency: 20Hz - 1kHz High frequency: 1kHz - 20kHz Shelf gains: 15dB in 0.1dB steps. Limiters Threshold: +22dBu to -10dBu Attack time: 0.3 to 90 milliseconds Release time: 2/4/8/16/32 x Attack time High and Lowpass Filters Filters: 1 of each per output. Freq. Range HPF: 10Hz - 16kHz 1/36 octave steps. Freq. Range LPF: 35Hz - 22kHz 1/36 octave steps. Responses: Bessel/Butterworth 12-18-24dB/Oct. Linkwitz-Riley 24dB/Oct. Input meter: 2 x 4 point, -24dB to digital clip. Output meter: 6 x 4 point, -24dB to +4dB into limit. Connectors Inputs: 3 pin female XLR Outputs: 3 pin male XLR. MIDI In: 5 pin DIN External: 9 pin DEE connector (RS232) RS485:3 pin male XLR (out) 3 pin male XLR (in) Power: 3 pin IEC Power: 60 to 250V 15% @ 50/60Hz. Consumption: < 20 watts. Weight : 3.5kg. Net (4.8kg. Shipping) Size: 1.75"(1U) x 19" x 11.8" (44 x 482 x 300mm) excluding connectors. Options u = Transformers available. Optional Interfaces AES/EBU Digital Input/Output
Due to continuing product improvement the above specifications are subject to change.
Page 2
DP6i Operators Manual
DP6i Quick Reference
THINGS YOU NEED TO KNOW The parameters and their values are listed in the table below.
Parameter ID NUMBER INTERFACE Values Notes
Shadow IDs only available when interface is set to slave (INTERFACE 06 - 08) Master RSbaud Master RSbaud Master RSbaud Master RSbaud Master RSbaud Master RSbaud Slave RSbaud Slave RSbaud Slave RSbaud Master RSbaud & Wiser Wireless MIDI Relay Off MIDI Relay ON channel specific only available when Interface is set to Master (00 - 05) Midi Relay ON omni on Analogue in Analogue out Analogue in Digital out Digital in Analogue out Digital in Digital out if no AES interface is fitted or interface is set to Slave (06 08), display will be fixed at AA GPI OFF if no GPI interface fitted, display will be fixed at Off GPI ON works in simple mode only
00 - 09 Of 01 - 16 Al AA Ad DA DD of on
By default, the LED display shows the last recalled memory number as long as the memory hasnt been edited remotely then it will display.
The memories cannot be recalled using the quick access keys unless the unit is in the default mode i.e. no yellow parameter LEDs are illuminated (with the exception of the Shadow LED). Initially there will be no memories stored in the unit, so the quick memory recall buttons will not function. The Mute Unit key will silence the entire unit, but the meters will continue to function. The remote software is unaware of this mute function it is local control only.
Page 3
Contents
Important Safety Information Unpacking the DP6i Introduction Front Panel Familiarisation Operating the DP6i
Note about operation with Start-up procedure Preliminary Set-up Quick Memory Recall Keys Mute Unit Key WindowsTM software.
Interface Operation Guides
RS232 Interface RS232 Connection (Single Unit) Shadow ID Numbers RS485 Interface RS485 Connection Midi Interface Midi Connection GPI Interface
Locking the Unit Remotely DP6i Configurations
Introduction 2 x 2 way with Mono Sum 2 x 3 way 4 way + way + way
AES / EBU Operation Guide
AES / EBU Connections
Operating Notes
Operating Level Grounding Crossover Filter Slopes Time Alignment Output Limiters Setting Accurate Limiter Thresholds
Specifications Warranty Options and Accessories Appendices
Appendix 1: Limiter threshold in dB to Vrms lookup table. Appendix 2: Default X-over settings and names for all formats. Appendix 3: Additional Information: General Purpose Interface
Page 4
An example of this equipment has been tested and found to comply with the following European and international Standards for Electromagnetic Compatibility and Electrical Safety: Radiated Emissions (EU): RF Immunity (EU): Electrical Safety (EU): EN55013-1 (1996) EN55103-2 (1996) RF Immunity, ESD, Burst Transient, Surge, Dips &Dwells EN60065 (1993)
Important Safety Information
Do not remove Covers. No user serviceable parts inside, refer servicing to qualified service personnel. This equipment must be earthed.
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
ATTENTION RISQUE DE CHOC ELECTRIQUE NE PAS ENLEVER
NE PAS EXPOSER A LA PLUIE NI A LHUMITE It should not be necessary to remove any protective earth or signal cable shield connections. Do not defeat the purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade and the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. Only use this equipment with an appropriate mains cord. In the USA the cord should comply with the requirements contained in the Standard for Cord Sets and Power Supply Cords, UL 817, be marked VW-1, and have an ampacity rating not less than the marked rating of the apparatus.
Page 5
Thanks
Thank you for choosing the XTA DP6i for your application. Please spend a little time reading through this manual, so that you obtain the best possible performance from the unit. All XTA products are carefully designed and engineered for cutting-edge performance and world-class reliability. If you would like further information about this or any other XTA product, please contact us. We look forward to hearing from you in the near future.
Unpacking the DP6i
After unpacking the unit, please check it carefully for any damage. If any is found, immediately notify the carrier concerned - you, the consignee, must instigate any claim. Please retain all packaging in case of future re-shipment.
Page 6
Introduction
The DP6i is a powerful DSP based audio processor, ideally suited for install applications, where it combines the functions of a multitude of conventional products in a compact 1U unit with extensive remote control capabilities. To achieve this, the DP6i has two inputs and six outputs which can be configured in five basic crossover modes 3 x 2 way; 2 x 3 way; 4 way; 5 way; and 6 way. Each input has a gain control, variable delay and eight bands of fully parametric equalisation. Each output has a gain control, variable delay, high and low pass filters, five bands of fully parametric equalisation, polarity switching and, additionally, a fully featured limiter. Remote control1 is catered for in the form of MIDI, RS232 and RS485 ports, and multiple user memories are provided for the storage and recall of settings. Security lock-out is available for all controls. The DP6i is also available with optional AES/EBU digital inputs and outputs. It may be controlled externally by XTAs proprietary WindowsTM software, along with existing and future Audiocore products. Features Superb audio quality carefully optimised double precision signal processing coupled with a 40-bit internal data path ensures a dynamic range in excess of 110dB. The high sampling rate means minimal filtering providing exceptional sonic purity. A flexible 2-input/6-output multi-mode format caters for any configuration, regardless of scale. A total of 46 parametric equalisation bands are available, each providing +15 to 30dB of gain at centre frequencies between 20Hz and 20kHz, with a wide range of Qs available between 0.4 to 128. All parameters feature fine resolution with 1/36 octave frequency steps, 0.1dB gain increments, and 100 Q settings. Any parametric section can also be set to operate as a high or low shelving filter. Each output features a high performance limiter, provided with complete control over attack, release and threshold parameters. To aid set-up, the output meters show headroom to the limiter threshold, and use time constants that track those of the limiter to display precise power usage.
Note that only the RS232 and RS485 interfaces offer full remote control of this product the MIDI interface may only be used for memory recall (program change) purposes DP6i Operators Manual Page 7
Each output features variable high and low pass filters, with a choice of 12, 18 or 24dB/Octave roll-off, and Butterworth, Bessel or Linkwitz-Riley responses. Independent control of each high and low pass filter allows asymmetric crossover bands to be created. Delay of up to 650mS may be independently set for each output, with an exceptionally fine minimum increment of 2.6S. The comprehensive standard specification also includes 40 memories, and remote control via MIDI, RS232 or RS485 ports, with security lock-out. AES/EBU Digital input and output interfaces are available as an option. Input and output balancing transformers are also available as an option. A general purpose interface (GPI) is available as a option, allowing simple remote memory recall without the need to connect a PC.
Page 8
Front Panel Familiarisation
Select Key: Pressing this key will cycle through the options listed to the right of the key each one will be highlighted in turn, with the LED display showing the value of the parameter. Adjust Keys: Use these keys to alter the value of the parameter currently selected. Note that in certain circumstances, such as where an option is not fitted, (AES or GPI) the value may not be adjustable. LED Display: This display shows, by default, the number of the last recalled memory. If this memory has been edited, the display will show. If a parameter is being adjusted, the yellow LED beside its name will be illuminated, and the current value of it will be shown on the display.
Input and Output Metering: Input meters show the headroom available below the clipping point of the analogue to digital converter. They are PREprocessing, so are not affected by the gain controls for the inputs or any applied equalisation. If the unit is clipping internally due to a DSP overflow (too much gain or excessive EQ), both CLIP LEDs on the inputs will illuminate, regardless of the actual input level, or which channel is overloading. Mute Unit Key: Pressing this will instantly mute all the outputs. Note that the metering will continue to register. The state of this mute will be remembered on power down. Note that the remote PC controller has no knowledge of this key, as it is purely a LOCAL mute facility. Output Meters: These show the headroom below limiting for the outputs. Adjusting the limiter threshold will cause the meter reading to change. The red LED illuminates when the level has reached 4dB over the limiter threshold. The ballastics of these meters are affected by the attack and release settings of the limiter. Quick Memory Recall Keys: Pressing one of these keys will immediately recall the relevant memory location. See page 11 for more details of how this works.
Shadow ID Numbers Shadow ID numbers allow extra units to share the same ID and follow the settings of the main ID. This is useful for larger systems (for example anything above a 3-way stereo system) where it is only necessary to set up one side of the system, and allow the other unit to track it identically. Using the shadow IDs in this way also reduces the apparent system complexity within Audiocore. This is due to the fact that shadow IDs NEVER send back any settings to Audiocore and because of this will NOT appear in the list of connected units. They can be thought of as listening to and acting upon all information addressed to them, but not replying. Up to 31 shadow units may be connected and assigned the same ID as the main unit, but remember that the maximum total units on any one RS485 network is 32. Shadow ID numbers are accessible when the units interface is configured as a slave (interface types 06 08), and will appear after ID number 32, starting from 01 again, but with the SHADOW LED illuminated.
Page 14
RS232 Connection (Multiple Units) If control over multiple units is required, typically the slaves will be set up to run from the RS485 ports on the master DP6i. Note the incremental ID NUMBER option in the units setup.
Page 15
RS485 Interface This interface is fitted as standard to all units and is accessed via the 3-pin XLR sockets on the rear of the unit. Cables to connect units together or to an RS232-485 converter will need to be wired one-to-one. We recommend the use of standard shielded microphone cables, or a balanced feed from a multicore. RS485 is a fully balanced system, capable of sending data over distances of up to one kilometre. Note, however, that this is the total length of connection. The RS485 output of each unit is purely hardwired from the input and so no electrical regeneration of the signal is provided. What this means is that the distance from the first RS485 output to the last RS485 input must not exceed 1km in total.
Cable 01 + Cable 02 + Cable NN < 1000 metres
Page 16
RS485 Connection To use RS485 communication directly from a computer, a master DP6i must be configured to receive RS485. You must have a suitable RS485 port on your computer, or a converter connected to the serial port in use. This configuration is shown below, along with the required unit setup.
Both the converter and the required adapter cables are available from XTA. The converter is part number OPT-103A. The adapter is available in a kit which includes an RJ-45 adapter; the XLR to 9-pin adapter, and the converter itself. This complete kit is part number INT-485. If you need to make up one of the XLR to 9-pin adapters, the pin-out is: XLR 3 D-type 8
Page 17
Midi Interface NOTE: This interface may only be used to trigger memory recalls. This interface is fitted as standard to all units and is accessed via the 5-pin DIN socket on the rear of the unit. A standard MIDI cable (that is a 5pin DIN male to male wired one-to-one) will be needed to connect the unit to the MIDI interface, be it an external unit (probably in the case of a laptop) or an internal card (desktop PC). The MIDI connection will not provide full control/monitoring facilities due to the fact that it is an input only. However, it does allow for scene changes in any sequencer or control package that supports MIDI program change messages. The memory map is given below. Program Change 1 40: Program Change 65 73: Program Change 97 105: Recall INPUT memories 1 - 40 Recall INPUT + X-OVER memories 1 - 9 Recall X-OVER memories 1 - 9
All other program changes sent to the unit will have no effect. Midi Connection To use MIDI communications, the DP6i must be configured to receive as a master via its MIDI port. You must have a MIDI card or interface connected to your computer or suitable device. The setup is shown below.
Page 18
GPI Interface In certain circumstances the connection of a computer to a DP6i is both impossible and undesirable, perhaps for reasons of unnecessary complexity and cost. This is where the general-purpose interface option becomes useful. It permits the recalling of memories (input, crossover, or both) from a remote location, without the need for expensive interface controllers. Memories may be recalled using a simple wired interface. The configuration and set-up of the interface is covered in Appendix 3 on page 36, as it is an option that is not fitted as standard.
Page 19
Locking the Unit Remotely
Supplied with the DP6i is a remote locking program. This allows all the connected units to have their front panel controls locked out, including the Mute Unit key and the Quick Memory Recall keys. Starting the program will display a window as shown below.
The connection should be the same as that used via Audiocore to control the unit please see the preceding sections for information about this. Audiocore remote control is still possible when the unit is locked. Pressing the Lock Units button will ask for a password and confirmation of the same password again. Pressing the OK button will send this password to ALL connected units and lock them. Confirmation of the lock is given by the units briefly showing LC on their displays. Note that the password is stored in each unit, so if it is required to give a different password to each unit in a network, they will have to be connected individually to the computer. Note that shadow units will be locked at the same time, but must be connected through a master for the program to work. There is NO master unlock password please contact XTA if you need to unlock your unit. There is a procedure for achieving this (without losing the settings stored in the unit), but you wont find details of it here! Unlocking units is as simple as pressing the Unlock Units button, entering the password, and pressing OK. Confirmation of the unit(s) unlocking is confirmed by the display(s) briefly showing uC.
Page 20
DP6i Configurations
Introduction To simplify the set-up of the DP6i, 5 crossover modes are selectable. These all have parametric equalisers, high and low pass filters, gain controls, delay and limiters. The following set of diagrams detail how each of the five modes is internally configured. Note that the 2 x 3 way and 3 x 2 way modes also offer the option of ganged parameter adjustment for stereo systems.
2 x 2 way with Mono Sum This format feeds input A to outputs 1 and 2, designated low and high respectively. Input B feeds outputs 3 and 4, low and high respectively. Outputs 5 and 6 are both fed from the sum of inputs A and B. Output 6 is a full bandwidth output by default, with output 5 being bandwidth limited as a sub output. The choice of whether this summed signal is pre or post input EQ is made during the selection of this crossover configuration. Any changes made to the crossover points or EQ will not be affected by swapping from pre to post or vice versa.
Page 21
2 x 3 way This format feeds input A to outputs 1, 2, and 3 designated low, mid, and high respectively. Input B feeds outputs 4, 5, and 6, as low, mid, and high respectively. Note that this configuration, as with the 2 x 2 way, can have the outputs ganged for stereo operation. This gangs outputs 1 & 4, 2 & 5, and 3 & 6, so that they track identically. Any changes made to the crossover points or EQ will not be affected by swapping from pre to post or vice versa.
Page 22
4 way + 2 This format feeds input A to outputs 1, 2, 3, and 4 designated low, lo-mid, hi-mid and high respectively. Outputs 5 and 6 are configured as auxiliaries, with their source being either input B, or the sum or inputs A and B. The choice of pre or post input EQ for the sum signal is only offered if outputs 5 and/or 6 are chosen to feed form the sum. This configuration also allows all the input EQ to be moved to input A, giving 16 bands of fully parametric EQ. If there does not appear to be any EQ on input B, this will be why.
Page 23
5 way + 1 This format feeds input A to outputs 1, 2, 3, 4, and 5 designated sub, low, lo-mid, himid and high respectively. Output 6 is configured as an auxiliary, with the source being either input B, or the sum or inputs A and B. The choice of pre or post input EQ for the sum signal is only offered if output 6 is chosen to feed form the sum. This configuration also allows all the input EQ to be moved to input A, giving 16 bands of fully parametric EQ. If there does not appear to be any EQ on input B, this will be why.
Page 24
6 way This format feeds input A to all outputs designated lo-sub, through high, 1 to 6 respectively. This configuration also allows all the input EQ to be moved to input A, giving 16 bands of fully parametric EQ. If there does not appear to be any EQ on input B, this will be why.
Page 25
Connection of AES/EBU signals is via the existing rear panel XLR connectors. With the AES/EBU option fitted, selection of the routing options is possible as follows. Use the SELECT key to scroll down the parameters until the AES LED is illuminated. If the interface has been fitted correctly, it will not be possible to change the display on the screen to one of four options as below:
aa Analogue in -> Analogue out ad Analogue in -> Digital out da Digital in -> Analogue out dd Digital in -> Digital out
AES / EBU Connections The AES/EBU digital signal is a stereo data stream, and so only one input XLR and three output XLRs are used for the digital interface. The connections are as follows: Input A Input B Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Analogue Input at all times Switchable between digital (stereo) input and analogue input Switchable between digital out (for channels 1 & 2) and analogue 1 Switchable between digital out (for channels 3 & 4) and analogue 2 Switchable between digital out (for channels 5 & 6) and analogue 3 Analogue output 4 only Analogue output 5 only Analogue output 6 only
Note that the internal sampling rate of the DP6i is 48kHz. When the analogue in to digital out route is chosen, the output sample rate will therefore be 48kHz. This cannot be changed. When using a digital input, however, the DP6i will lock to any sample rate from 32kHz up to 48kHz, and this will be the outgoing sample rate as well. Please be aware that as all filter coefficients and time delays are calculated based on the units professional sample rate of 48kHz, there will be an offset introduced if any other rate is used. For example, if the consumer sample rate of 44.1kHz is used, then all filter frequencies must be shifted down by a factor of 44.1/48 or 0.92. Hence a 1kHz filter will actually be centred at 920 Hz and so on. Time related features such as delays and limiter attack and release times must be shifted up by a factor of 48/44.1 or1.09. Hence a set delay time of 100mS will actually be 109mS, and a limiter attack time of 4mS will become 4.36mS.
Page 26
Operating Level With any audio signal processing equipment it is necessary to ensure adequate signal level is used through the device, to avoid sacrificing noise performance. It is suggested that the operating level chosen should give adequate level to just light the -12dB LED on the headroom meter with maximum program level being used. Since the meter is deliberately set to show clipping 3dB early, this still provides 9dB of headroom before clipping occurs. With equalisation in use it may be necessary to further reduce the input level, as gain within the unit may cause digital clipping, indicated by the top red LED's lighting independently of the rest of the meter. It should be noted that the figure quoted for the maximum input level options is the clipping point for that option (not a safe operating level). Always ensure that this clipping point is no lower than that for the following equipment in the signal chain, and allow extra margin if equalisation sections are boosted. Grounding The Screen (shield) pins on all audio connectors are normally connected directly to the ground pin of the IEC mains inlet. The chassis is also directly connected to this pin. Never operate this unit without the mains safety ground connected. Signal ground (0V) is in turn connected to the chassis ground. To avoid ground loops, cable shields should be connected to ground at one end only. The normal convention is that the shield is only connected at the output XLR. Provision is also made for separately isolating each input and output shield pin permanently within the DP6i by breaking the appropriate PCB track, where marked with a box and an arrow next to each XLR connector using a small drill bit or cutter. See the following diagram for details.
XLR pin 1 Isolation points (arrowed) and 10dB pads (circled)
Page 27
Crossover Filter Slopes Please consult the block diagrams on page 11 for details of the various configurations available. All crossover modes feature adjustable crossover frequencies with a choice of slopes, 5 bands of driver compensation E.Q. per output and delay time plus limiters for each output. A powerful 8 band parametric equaliser is also provided on each input for room equalisation. Phase reverse is provided for each output. A choice of Bessel or Butterworth slopes at 12/18/24dB per octave and LinkwitzRiley at 24dB per octave are provided. Since Low and High pass functions are separately adjusted, asymmetric slopes are easily achieved, if required. It should also be noted that the turnover frequency displayed in Audiocore is the -3dB point for all slopes except 24dB Linkwitz-Riley where the -6dB point is shown. If the -6dB point is to be used for the Bessel or Butterworth filter, take the required crossover frequency, multiply this by the appropriate factor from the following table and then select the closest available frequency. Filter Type
Bessel 12dB/Oct. Butterworth 12dB/Oct. Bessel 18dB/Oct. Butterworth 18dB/Oct. Bessel 24dB/Oct. Butterworth 24dB/Oct.
High pass factors
1.45 1.31 1.37 1.19 1.35 1.15
Low pass factors
0.69 0.76 0.73 0.84 0.74 0.87
Please note that unlike conventional analogue crossovers, crossover points and slopes are set with absolute accuracy since component tolerance problems do not occur. Time Alignment A further advantage of the DP6i over conventional products is the provision of an independently adjustable delay section for each output. This allows the true arrival time from multiple drivers to precisely aligned rather than relying on the compromise 'phase adjust' approach. Delay time is adjustable in 2.6S steps (1mm). To convert from units of time (i.e. milliseconds) to units of distance use the following formula: 1 millisecond = 343mm (1.126ft) @ 20C (68F) To calculate time delay for a known distance, use: Time delay = Distance in meters 20.06 x 273+C where C is the temperature in C. To simplify this equation at 20C. Delay time in milliseconds = (Distance in meters x 2.192) or (Distance in feet x 0.955) Note: Centigrade = (Fahrenheit 32) x 0.5555.
Page 28
Output Limiters High performance digital limiters are provided for each output with control over attack time, release time and threshold level parameters. This level of control allows the user to balance the required subjective quality of the limiter against the driver protection requirements. It does also mean that an incorrectly set limiter may sound awful! In particular, as with all limiters, using too fast an attack or release time will result in excessive low frequency distortion. On the Limiter control screen within Audiocore there is an option for automatic limiter time constants. In this mode the time constants will be automatically set from the Highpass filter frequency according to the table below. The time constants are set by the high pass filter frequency for that channel. High Pass Filter <10Hz 31Hz 31Hz 63Hz 63Hz 125Hz 125Hz 250Hz 250Hz 500Hz 500Hz - 1kHz 1kHz 2kHz 2kHz 22kHz Auto Attack Time 45mS 16mS 8mS 4mS 2mS 1mS 0.5mS 0.3mS Release Time x16 (720mS) x16 (256mS) x16 (128mS) x16 (64mS) x16 (32mS) x16 (16mS) x16 (8mS) x16 (4mS)
Page 29
Setting Accurate Limiter Thresholds The limiters built into the DP6i are intended to be used for loudspeaker driver protection, as opposed to amplifier protection. All modern professional power amplifiers designed for live sound use have their own limiters, which are tailored to protecting the amplifier from clipping. The following section describes how to set up the DP6is limiters to provide exceptional protection against driver overheating, and cone over-excursion. Most speaker systems are given a power rating in Watts RMS. This is the maximum continuous power that the system will handle and often appears very conservative. In reality, as music program is far from continuous in nature, the peak power of the system is much higher up to ten times the continuous figure. Any limiter, which is to protect the driver from damage, must be able to fulfil the following tasks. Have an attack time which is calculated to allow transients through but keep the RMS level below the speaker manufacturers specification; Have a release time which is sufficiently long to avoid the limiter itself modulating the program ; Be intelligent enough to adjust the envelope of the limiter according to the frequency content of the program material.
The DP6is limiters are capable of performing all these tasks. The only parameter which the user must set manually is the threshold, and it is crucial that this is done correctly. Consider the table below. dB Ratio 177.83 158.49 141.25 125.89 112.20 100.00 89.13 79.43 70.79 63.10 56.23 50.12 44.67 39.81 35.48 31.62 Vrms 137.74 122.77 109.41 97.52 86.91 77.46 69.04 61.53 54.84 48.87 43.56 38.82 34.60 30.84 27.48 24.49 Pwr 8 2371.71 1883.91 1496.45 1188.67 944.19 750.00 595.75 473.22 375.89 298.58 237.17 188.39 149.64 118.87 94.42 75.00 Pwr 4 4743.42 3767.83 2992.89 2377.34 1888.39 1500.00 1191.49 946.44 751.78 597.16 474.34 376.78 299.29 237.73 188.84 150.00 Pwr 2 9486.83 7535.66 5985.79 4754.68 3776.78 3000.00 2382.98 1892.87 1503.56 1194.32 948.68 753.57 598.58 475.47 377.68 300.00
Using this table it is a straightforward procedure to work out the required setting of the limiter thresholds for the system. Follow the steps described overleaf.
Page 30
First, check the RMS power rating of the speaker system, and its impedance. Look up this value in the table above, using the closest value below the rated power of the speaker system. Note the corresponding dB value. Check the gain of your amplifier, which needs to be in dB. Subtract this gain figure from the dB value obtained from the table to find the required absolute setting for the limiter thresholds. Note that, for safety, always set the limiter threshold 1 or 2 dB below the maximum allowable worked out using the above method. ALWAYS REFER TO YOUR SPEAKER MANUFACTURER FOR LIMITER SETTINGS.
Page 31
Specifications
Inputs: 2 electronically balanced Impedance: > 10k ohms. CMRR : >65dB 50Hz - 10kHz. Outputs: 6 electronically balanced Source Imp: < 60ohms Min. Load: 600ohm Max. Level: +20dBm into 600 ohm Frequency Resp.:+dB 20Hz-20kHz Dyn Range:>110dB 20Hz-20k unwtd Distortion:<.02%@1kHz,+18dBm Maximum Delay: 650 mS Min Step Size: 2.6 S Input Gain: +6dB to -40dB in 0.1dB steps Output Gain: +15dB to -40dB in 0.1dB steps and mute Parametric Equalisation 8 per Input / 5 Sections per Output Filter Gain: +15dB to -30dB in 0.1dB steps. Freq. Range: 20Hz - 20kHz, 1/36 octave steps. (368 positions) Filter Q / BW: 0.4 to 128 / 2.5 to 0.008 (Sections switched to shelving response) Low frequency: 20Hz - 1kHz High frequency: 1kHz - 20kHz Shelf gains: 15dB in 0.1dB steps. High and Lowpass Filters Filters: 1 of each per output. Freq. Range HPF: 10Hz - 16kHz 1/36 octave steps. Freq. Range LPF: 35Hz - 22kHz 1/36 octave steps. Responses: Bessel/Butterworth 12-18-24dB/Oct. Linkwitz-Riley 24dB/Oct. Limiters Threshold: +22dBu to -10dBu Attack time: 0.3 to 90 milliseconds Release time: 2/4/8/16/32 x Attack time Display: 2 x 7-segment LED Input meter: 2 x 4 point, -24dB to digital clip. Output meter: 6 x 4 point, -24dB to +4dB into limit. Connectors Inputs: 3 pin female XLR Outputs: 3 pin male XLR. MIDI In: 5 pin DIN External: 9 pin DEE connector (RS232) RS485:3 pin male XLR (out) 3 pin male XLR (in) Power: 3 pin IEC Power: 60 to 250V 15% @ 50/60Hz. Consumption: < 20 watts. Weight: 3.5kg. Net (4.8kg. Shipping) Size: 1.75"(1U) x 19" x 11.8" (44 x 482 x 300mm) excluding connectors.
Options = Transformers available. Optional Interfaces AES/EBU Digital Input/Output
Due to continuing product improvement the above specifications are subject to change.
Page 32
Warranty
This product is warranted against defects in components and workmanship only, for a period of one year from the date of shipment to the end user. During the warranty period, XTA will, at it's discretion, either repair or replace products which prove to be defective, provided that the product is returned, shipping prepaid, to an authorised XTA service facility. Defects caused by unauthorised modifications, misuse, negligence, act of God or accident, or any use of this product that is not in accordance with the instructions provided by XTA, are not covered by this warranty. This warranty is exclusive and no other warranty is expressed or implied. XTA is not liable for consequential damages.
Options and Accessories
Part Number ITX-100 OTX-100 AES-6i OPT-103A OPT-103B OPT-103C INT-485 OPT-GPI Part Description DP6i Transformer balanced inputs (factory fitted only) DP6i Transformer balanced outputs (factory fitted only) AES/EBU Digital inputs/outputs (factory fitted only) RS232 to RS485 converter (from PC to DP6i) 9 pin D type to XLR male adaptor cable 9 pin D type to 9 pin D type cable. (1m) Kit comprising OPT103A/B/C GPI Interface Kit
Page 33
Appendices
Appendix 1: Limiter threshold in dB to Vrms lookup table. dB +22 +21 +20 +19 +18 +17 +16 +15 +14 +13 +12 +11 +10 +9 +8 +7 +6 Vrms 9.75 8.69 7.75 6.90 6.15 5.48 4.89 4.36 3.88 3.46 3.08 2.75 2.45 2.18 1.95 1.73 1.55 dB +5 +4 +3 +2 +-1 -2 -3 -4 -5 -6 -7 -8 -9 -10 Vrms 1.38 1.23 1.09 0.98 0.87 0.77 0.69 0.62 0.55 0.49 0.44 0.39 0.35 0.31 0.27 0.24
Calculation: Vrms = 0.7746 x 10 ^ (dBu + 20)
Page 34
Appendix 2: Default X-over settings and names for all formats. X-over
2x2 way+Ms
Output 1 Low
Output 2 High
Output 3 Low
Output 4 High
Output 5 Msub
Output 6 Aux
120Hz 1k82Hz 1k82Hz 22kHz 120Hz 1k82Hz 1k82Hz 22kHz 24.8Hz 120Hz <10Hz 22kHz
2 x 3 way
22.1Hz 120Hz 120Hz 1k82Hz 1k82Hz 22kHz 22.1Hz 120Hz 120Hz 1k82Hz 1k82Hz 22kHz
4 way + 2
15Hz 149Hz 149Hz 1k31Hz 1k31Hz 8kHz
8kHz 22kHz 20.1Hz 22kHz 20.1Hz 22kHz
5 way + 1
15Hz 80.3Hz 80.3Hz 180Hz 180Hz 1k31Hz 1k31Hz 8kHz
8kHz 22kHz 20.1Hz 22kHz
1kHz 4kHz
15Hz 80.3Hz 80.3Hz 149Hz 149Hz 1kHz
4kHz 10k1Hz 10k1Hz 22kHz
Note: All filters set to 24dB Linkwitz-Riley.
Page 35
Appendix 3: Additional Information: General Purpose Interface The GPI (General Purpose Interface) allows the recall of memories via an external switch box, alleviating the need for a computer system when only memory changes are needed. This information is reproduces in the application note that accompanies the GPI kit itself. The following parts are contained in the GPI Kit. One GPI Interface card; One 15pin D-type to 9pin D-type adaptor; One male 15pin D-type with hood; Software upgrade disk; One application note. Hardware Installation. Ensure that the unit is switched off and that the power cord is removed from the mains supply! Position the unit so that the front panel is facing you, remove the seven retaining screws from the top cover and place the screws and cover to one side. Now locate the RS232 card and remove the retaining bolts (5mm) from the rear of the unit and unclip the connector from the main circuit board. The card can now be removed and the GPI card put in its place. Be sure to tighten the retaining screws but be careful not to strip the thread. The installation of the card is now complete - please replace the top cover. What can I do with the GPI interface? The GPIP interface allows the recall of the first 7 memories in your DP6i via a simple contact closure interface. The rules for what is recalled are simple: If you have stored something in input memory number N and x-over memory number N, they will both be recalled when you select N. If only an input memory is stored at number N it will be recalled on its own, and similarly for the case of only a x-over memory. Trying to recall a location where no memory is stored will not do anything. What do I need to plug in to recall a memory? On the following page there are two example circuit diagrams of GPI switches. The first is a self powered version, that is it takes its power from the unit and is therefore not fully isolated from the unit. The second diagram is a powered version, this gives full isolation from the unit, it should be noted however that no more than 10v should be used to activate the opto isolators as damage could occur.
Page 36
Note that either individual momentary action or latching switches may be used. Additionally, a rotary switch may be used, but realise that this will mean that the seven memories will only be accessible in a linear fashion. Individual switches allows Random Access of the memories in any order which might be more useful. The type of switch used to build a remote interface is not crucial, but XTA suggest the following as suitable. Farnell Components Order Code 176-477 (Momentary Push-button Variety) Farnell Components Order Code 176-478 (Latching Push-button Variety) Farnell Components Order Code 176-487 (Mounting Bracket for Interlocking Set) Farnell Components Order Code 176-516 (Interlocking Cam) Farnell Components Order Code 176-491 (Round Caps) Farnell Components Order Code 176-492 (Rectangular Caps) For a rotary switch we suggest: Farnell Components Order Code 422-381 (Rotary Non-Shorting) Note that the rotary switch must be a break before make variety, or unpredictable operation may occur.
Page 37
Examples of two typical interfaces that may be used to operate the interface.
15-way D-type
Momentary Action Switch (Mem #01)
Momentary Action Switch (Mem #07)
Connection using crossovers own power supply. Connect pin 5 to pin 9.
Momentary Action Switch (Mem #01) +9volts
Connection using external battery supply (9 volt).
Page 38
How Do I Configure The Interface? Use the SELECT key to scroll down the parameters until the GPI LED is illuminated. If the interface has been fitted correctly, it will not be possible to change the display on the screen from of to on. Its as simple as that! Note that any recalls initiated using the GPI interface will relay a memory recall command out of the RS485 port, allowing all connected units to respond and change configuration at the same time. How Do I Trigger a Memory Recall? As can be seen from the schematic diagrams, operation just involves connecting a single pin of the socket to a positive supply, derived either from the unit (non-isolated ground must also be connected from pin 5 to pin 9), or from an external supply. In the case of the external supply, its ground must be connected to pin 9 to complete the circuit. Only a momentary action switch is required, but latching ones may be used if a physical indication of the remote memory selected is required.
Pin 11
Pin Numbering of 15-pin connector (as viewed from the rear of the unit)
Have I Lost My RS-232 Port? No. The circuitry for the RS-232 port is included on the GPI card. An adapter is included in the GPI kit which plugs into the 15-pin connector, and converts it to the original 9-pin which may be used in exactly the same way as before. The port may be used for loading software upgrades, and remote control applications.
Tags
IC-W2a-E EMT10 VGC-LN1MR LX300 Graph35 LC-26D44E DSC-S750 SGH-X461 VB-99 AST-A10 Logicom G353 787C2 KF310 UX-BD80 Bd90 Ketron XD3 LE40M73BD YZ250F-2008 LFA840 47PFL5603H Nokia 2280 NNA554W VP-D102D Polaroid A520 Individual SV-651F Xxx 6 Palm OS 240V SA-PM19 TXL37S10E HTR-5230 FS-1535 BAR 12F CIT300 5 Lens CLX-3185 BKF 355 Systems 9 9D SDC-810II DD505 F900P-fb910g-ul- Concert Navi 3109C RM4200S TS320GSJ25P Octane R SLV-X9N 9 1 Simpson SLV-D920E Ericsson T237 ESF489 Photo R350 FOR Ps2 ICF-S10mk2 SCC 1501 LS-S1260HL PD-S504 CT-W606DR Optura 300 GSM712 HL-760 CDX-GT310 ENP-2322B ROC 3205 Igo 8 Satellite 2800 EEE PC PE-48A82T DCR-SR220 RS-1500US HL-2600CN Release 6 Model 150X Tecra A5 UE-46C5100 Zoom H2 Review Globalmap 100 CX3600 DVD-S35 D-copia 120 WL-600G STI64BF1 Proceed PAV A7V133-VM 8030A KX-R190 09er 12ER Powershot A20 MDX-C5400 Ensoniq SQ-2 1490LMT 82157 8020A Shark 8260 CP-X417WF BJC-5100 UX-A1000 VG710B
manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding