Manual

Download (English)

 

Omron 3G3MV

 

 

User reviews and opinions

<== Click here to post a new opinion, comment, review, etc.

No opinions have been provided. Be the first and add a new opinion/review.

 

Documents

doc1

OMRON IDM CONTROLS, INC.
3G3MV SYSDRIVE AC Inverters
Compact, general purpose AC inverter delivers reliable speed control and easy integration with PLCs
Omrons SYSDRIVE 3G3MV Series AC Inverter
Giving you the perfect combination of advanced speed control and customized functionality in an extraordinarily compact housing! This powerful inverter really delivers. Its maximum output frequency of 400Hz makes it ideal for small motor control (1/8 12.5 HP) in a wide variety of applications It is feature-packed with 179 userconfigurable parameters that let you customize the inverters operation to your specific application. This small but powerful inverter is easy to set up, wire and operate. Whats more, the 3G3MV inverter lets you select the control method that best suits your needs sensorless voltage vector control or standard Volts/Hz. Standard models provide energy saving function and PID control.
SHOWN AT ACTUAL SIZE - 128 mm (5.04 in.)
Compact And Cost Effective
Measuring only 5 inches high, it will fit in the smallest spaces, saving you panel space and size. Easily mount the 3G3MV on a DIN rail using its DIN rail-mounting bracket.

Multi-Function I/O

Wiring the 3G3MV is simple with easy to use screw terminals that accept 0 -10 V, 4-20 mA or 0 - 20 mA analog signals or pulse train inputs between 0.1 kHz and 33 kHz (scalable). It also offers analog and digital outputs for direct monitoring and control. The multi-function inputs can be set to either PNP or NPN, providing flexibility in input signals.
Easy To Set Up, Run And Monitor
The simple digital operator controls all function selections and operation. Despite its incredible 179-parameter configurability, all settings are defaulted to typical use settings that let you get up and running quickly. In addition, a convenient analog speed dial allows easy adjustment to the exact speed for your application.
Extensive Protective Functions
With its built-in stall prevention, ground fault protection, and auto recovery functions, you can count on the 3G3MV for reliable operation. The unit also features built-in functions like current limit and UL listed thermal overload protection to prevent damage and downtime, while ensuring smooth motor operation.

Versatile Communications

The 3G3MV inverters support RS-422 and RS-485 communications and can support DeviceNet via an optional communications board.
Global Construction Meets international UL, cUL and CE standards for global application coverage.
Sensorless Vector Control
Choose Volts/Hz for general purpose applications or sensorless Voltage Vector control when high torque output at lows speeds is critical (150% torque at 1 Hz). Comparison of Torque Characteristics

Vector control

(%) 300
Special functions include:
Programmable soft starts Motor slip compensation 16 preset speeds Full range automatic torque boost Speed search PID control Multi-function I/O Energy saving function Stall prevention Parameter copy function Skip frequencies The 3G3MV gives you the performance and reliability of larger inverters at a fraction of the size and cost.

V/f control

Example: 0.4 kW at 400 V

Torque

60 (Hz)

Operating frequency

Intuitive Digital Operator
From set up to wiring, the SYSDRIVE 3G3MV is designed for simplicity. Its user-friendly digital operator gives you easy access to all 179 of the inverters user selectable parameters. Additionally, the parameter copy function allows you to set up one inverter, save the parameters to the digital operators memory and download them into multiple 3G3MV inverters. This function can also be used to verify parameters between the digital operator and an inverter.

4-digit data display shows the drives operating conditions, parameter values and fault codes. While the default is Hz, the 3G3MV can be scaled to read out in engineering units like RPM. Quick start LEDs simplify monitoring the inverters status FREF - frequency reference can be monitored or set FOUT - output frequency can be monitored IOUT - output current can be monitored MNTR - monitor the status of important settings such as error logs, input & output terminal status, and PID characteristics F/R - direction of rotation can be selected or viewed LO/RE - operation from digital operator or set parameters can be selected PRGM - all accessible parameters can be set or monitored
Face-mounted analog dial provides easy speed control
Operation keys offer simple access to parameters. Increase or decrease parameter numbers, set numbers and multi-function monitor numbers.
Use the digital operators access control function to protect crucial parameter values

Industry

Food/Beverage Processing HVAC Machine Tool Printing Textiles Petrochemical Processing General Manufacturing Material Handling

Applications

Pumps Fans Conveyors Mixers Hoists Blowers Compressors Packaging

PLC Option Board

With Omron's 3G3MV inverter and PLC Option Board, you can bring more intelligence to your system by enhancing the speed and position control of your application. The 3G3MV-P10CDT Option Board offers the features of an Omron CPM2C-S PLC embedded directly into the inverter, providing single-point programming. The inverter-based design provides wireless installation and seamless integration with inverter parameters and I/O. Standard Omron software tools are used for programming and start-up. The 3G3MV-P10CDT is the perfect integrated solution for door control, pump sequencing, axis control, and general positioning. It can provide distributed control for an entire line, and because of its modular concept, your system can grow as your needs do. Six inputs and four outputs are available in the 3G3MV-P10CDT, with an instruction execution time of less than 8s. Omron's CX-Programmer and SYSDRIVE Configurator connect through standard serial connections.
DeviceNet Communication Unit
The 3G3MV-PDRT2 DeviceNet Communications Unit makes it possible for the SYSDRIVE 3G3MV to communicate over DeviceNet. The unit permits a PLC to monitor Run/Stop and operating conditions and make changes in set values. Remote I/O communications and message communications can be used simultaneously between the PLC and 3G3MV inverter.

Ordering Information

Rated Voltage 3-Phase 230 VAC Enclosure Type NEMA-1 For Open-Chassis IP-20 Models: replace C with A in part number Rated Output Current (A).8 1.6 3.0 5.0 8.0 11.0 17.33.8 1.6 3.0 5.0 8.0 11.0 17.5 1.8 3.4 4.8 5.5 8.6 14.Nominal Horsepower (kW).13 (0.1).25 (0.2).5/.75 (0.4) 1.0 (0.75) 2.0 (1.5) 3.0 (2.2) 5.0 (3.7) 7.5 (5.5) 10 (7.5).13 (0.1).25 (0.2).5/.75 (0.4) 1.0 (0.75) 2.0 (1.5) 3.0 (2.2) 5.0 (3.7) 1.0 (0.4) 1.5/ 2 (0.75) 3.0 (1.5) 3.0 (2.2) 5.0 (3.7) 10 (5.5) 12.5 (7.5) Part Number 3G3MV-C2001 3G3MV-C2002 3G3MV-C2004 3G3MV-C2007 3G3MV-C2015 3G3MV-C2022 3G3MV-C2037 3G3MV-C2055 3G3MV-C2075 3G3MV-CB001 3G3MV-CB002 3G3MV-CB004 3G3MV-CB007 3G3MV-CB015 3G3MV-CB022 3G3MV-CB037 3G3MV-C4004 3G3MV-C4007 3G3MV-C4015 3G3MV-C4022 3G3MV-C4037 3G3MV-C4055 3G3MV-C4075

Single-Phase 230 VAC

NEMA-1 For Open-Chassis IP-20 Models: replace C with A in part number

3-Phase 460 VAC

Note: Nominal HP rating based on standard 1800 RPM motor amperage. Please consult factory or refer to operation manual for MV-4X part numbers.
Description PLC Option Board DeviceNet Communications Unit 3-Phase, 230 VAC
Applicable Inverter Models All models All models 3G3MV- 2001/3G3MV- 2015/3G3MV- 2037 3G3MV- B001/3G3MV- B007/3G3MV- B022 3G3MV- B037 3G3MV- 4002/3G3MV- 4037
Part Number 3G3MV-P10CDT 3G3MV-PDRT2 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122A 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 3G3IV-PEZZ08122D 3G3IV-PEZZ08122B 3G3IV-PEZZ08122C 5
2002/- 2004/- B002/- B004 B015
DIN Rail Single-Phase, 230 VAC Mounting Bracket 3-Phase, 460 VAC
4004/- 4007/- 4015/- 4022

Specifications

Voltage Class
Part numbers Three-phase NEMA-1

MODEL 3G3MV-

Three-phase IP-20 Single-phase NEMA-1 Single-phase IP-20

Output Characteristics

NEMA 4X MODEL V7CUMax. Applicable Motor Output*1 HP (kW) Inverter Capacity (kVA) Rated Output Current (A) Max. Output Voltage (V) Max. Output Frequency (Hz) Rated Input Voltage and Frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation Control Method Frequency Control Range Frequency Accuracy (Temperature Change) Frequency Setting Resolution Output Frequency Resolution Overload Capacity Frequency Reference Signal Accel/Decel Time Braking Torque V/f Characteristics Motor Overload Protection Instantaneous Overcurrent Overload Overvoltage Undervoltage Momentary Power Loss Cooling Fin Overheat Stall Prevention Level Cooling Fan Fault Ground Fault Power Charge Indication Cooling Method Ambient Temperature
Humidity Storage Temperature*3 Location Elevation Vibration Wiring Distance

Input Signals

Multi-function Input

Multi-function Output

Standard Functions
230 VAC single- / three-phase 460 VAC three-phase C2001 C2002 C2004 C2007 C2015 C2022 C2037 C2055 C2075 C4004 C4007 C4015 C4022 C4037 C4055 C4075 A2001 A2002 A2004 A2007 A2015 A2022 A2037 A2055 A2075 A4004 A4007 A4015 A4022 A4037 A4055 A4075 CB001 CB002 CB004 CB007 CB015 CB022 CB037 AB001 AB002 AB004 AB007 AB015 AB022 AB037 20P24 20P44 20P74 21P54 22P24 23P74 25P54 27P54 40P44 40P74 41P54 42P24 43P74 45P54 47P54 0.13 0.25 0.5/.5 7.1 1.5/3.10 12.5 (0.1) (0.2) (0.4) (0.75) (1.5) (2.2) (3.7) (5.5) (7.5) (0.4) (0.75) (1.5) (2.2) (3.7) (5.5) (7.5) 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13.0 1.4 2.6 3.7 4.2 7.0 11.0 14.0 0.8 1.11 17.33 1.8 3.4 4.8 5.5 8.6 14.3-phase, 200 to 230 V (proportional to input voltage) 3-phase, 380 to 400 V (proportional to input voltage) Single-phase, 200 to 240 V (proportional to input voltage) 400 Hz (Programmable) 3-phase, 200 to 230 V, 50/60Hz 3-phase, 380 to 460 V, 50/60Hz Single-phase, 200 to 240 V, 50/60Hz -15% to +10% 5% Sine wave PWM (V/f control/voltage vector control selectable) 0.1 to 400Hz Digital reference: 0.01% (-10 to +50C) Analog reference: 0.5% (2510C) Digital reference: 0.01 Hz (less than 100 Hz)/0.1 Hz (100 Hz or more) Analog reference: (0:06/60 Hz) equivalent to 1/1000 of max. output frequency 0.01 Hz 150% rated output current for one minute 0 to 10 VDC (20 k), 4 to 20 mA (250 ), 0 to 20 mA (250 ) pulse train input, frequency setting potentiometer (Selectable) 0.00 to 6000 sec. (accel/decel time are independently programmed 2 types) Short-term average deceleration torque*2; 0.1, 0.25 kW (0.13 HP, 0.25 HP): 150%; 0.55, 1.1 kW): (0.5 HP, 1 HP): 100% 1.5 kW (2 HP): 50%; 2.2 kW (3 HP) or more: 20% Continuous regenerative torque: Approx. 20% (150% with optional braking resistor, braking transistor built-in) Possible to program any V/f pattern Electronic thermal overload relay Motor coasts to a stop at approx. 250% of inverter rated current Motor coasts to a stop after 1 minute at 150% of inverter rated output current Motor coasts to a stop if DC bus voltage exceeds 820 V Motor coasts to a stop if DC bus voltage exceed 410 V Stops when DC bus voltage is approx. 200 V or less Stops when DC bus voltage is approx. 400 V or less (approx. 160 V or less for single-phase series) Stops for 15ms or more. By setting inverter, operation can be continued if power is restored within approx. 0.5s Protected by electronic circuit Can be set individually during accel/decel, provided/not provided available during coast to a stop Protected by electronic circuit (fan lock detection) Protected by electronic circuit (overcurrent level) ON until the DC bus voltage becomes 50V or less. RUN lamp stays ON or digital operator LED stays ON. Cooling fan is provided for the following models: 200 V, 0.75 kW or larger inverters (3-phase) 200 V, 1.5 kW or larger inverters (single-phase) Others models are self-cooling Open chassis IP20: -10 to +50C (14 to 122F) Open chassis IP20 (Top-closed type) and enclosed wall mounted NEMA-1: -10 to +40C (14 to 105F) (not frozen) 95% RH or less (non-condensing) -4 to 140F (-20 to +60C) Indoor (free from corrosive gases or dust) 3280 ft (1000 m) or less Up to 9.8 m/S2 (1 G) at less than 20 Hz, up to 2 m/S2 (0.2 G) at less than 20 to 50 Hz 328 ft (100 m) or less between Inverter and Motor Seven of the following input signals are selectable: Forward/reverse run (3-wire sequence), fault reset, external fault (NO/NC contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock (NO/NC contact input), speed search command, UP/DOWN command, accel/decel hold command, LOCAL/REMOTE selection, communication/control circuit terminal selection, emergency stop fault, emergency stop alarm, self test, PID control cancel, PID integral reset/hold Following output signals are selectable (1 NO/NC contact output, 2 photo-coupler outputs): Fault, running, zero speed, at frequency, frequency detection (output frequency or set value), during overtorque detection, during undervoltage detection, minor error, during baseblock, operation mode, inverter run ready, during fault retry, during UV, during speed search, data output through communication, PID feedback loss detection Voltage vector control, full-range automatic torque boost, slip compensation, DC injection braking current/time at start/stop frequency reference bias/gain, MEMOBUS communications (RS-485/422, max. 19.2 K bps), PID control, energy-saving control, parameter copy, frequency reference with built-in potentiometer

*1: Based on a standard 4-pole motor for max. applicable motor output. Select the inverter model within the allowable motor rated current *2: Shows deceleration torque for uncoupled motor decelerating from 60 Hz with the shortest possible deceleration time *3: Temperature during shipping (for short period)

Other Functions

Environmental Conditions

Protective Functions

Control Characteristics

Power Supply

Output Signals

Dimensions

1.5 mm 0.06 in 1.5 mm 0.06 in

8.5 mm 0.33 in

W1 D W
IP-20 and NEMA 4X model dimensions will vary slightly, please refer to operation manual Voltage Class Model Number C2001 C2002 CVAC 3-Phase C2007 C2015 C2022 C2037 C2055 C2075 CB002 CBVAC Single-Phase CB007 CB015 CB022 C2037 C4004 CVAC 3-Phase C4015 C4022 C4037 C4055 C4075 mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch W 68 2.2.2.2.4.4.5.7.7.2.2.4.4.5.6.4.4.4.4.5.7.7.09 H 148 5.5.5.5.5.5.5.10.10.5.5.5.5.5.5.5.5.5.5.5.10.10.24 D 76 2.2.4.5.5.5.5.6.6.2.5.5.6.6.7.4.5.6.6.5.6.6.69 W2.2.2.2.3.3.3.6.6.2.2.3.3.5.6.3.3.3.3.5.6.6.46 H4.4.4.4.4.4.4.9.9.4.4.4.4.4.4.4.4.4.4.4.9.9.61 H0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.0.32 H5.5.5.5.5.5.5.10.10.5.5.5.5.5.5.5.5.5.5.5.10.10.24 H0.0.0.0.0.0.0.79 2.2 0.09 2.2 0.0.0.0.0.0.0.0.0.0.0.0.79 2.2 0.09 2.2 0.09 7

Standard Connections

Note: Connect single-phase 230 VAC to terminals R/L1 and S/L2 of the 3G3MV-CB.
Need an inverter for tough washdown or dust-tight environments?
MV-4X AC Inverter meets NEMA-4X requirements
The compact MV-Series inverter gives you the performance and reliability of larger inverters at a fraction of the size and cost. The new MV-4X provides the water and dust protection required for use in food and beverage processing, machine tools, wood working equipment, and printing machinery. Use this inverter in applications where plant floor equipment gets washed down with liquid, or is exposed to large amounts of dust or corrosives.
OMRON IDM CONTROLS INC. Houston, TX www.idmcontrols.com OMRON ELECTRONICS LLC Schaumburg, IL www.omron.com/oei OMRON CANADA, INC. Toronto, Ontario www.omron.ca
SB 3G3MV-2 5/03/XM 2003 OMRON ELECTRONICS LLC Printed in the U.S.A.

OMRON IDM HEADQUARTERS 800.395.4106 or 713.849.1900 UNITED STATES REGIONAL SALES OFFICE 847-843-7900 CANADA REGIONAL SALES OFFICE 416.286.6465 MEXICO SALES OFFICES Florida 954.227.2121 Ciudad Juarez 656.623.7083 Mexico, D.F. 555.534.1195 Monterrey, N.L. 818.377.4281 BRAZIL SALES OFFICE 55.11.5564.6488 ARGENTINA SALES OFFICE - CONO SUR 114.590.2408

AUTHORIZED DISTRIBUTOR:

 

Tags

MC13213 SGS 501 ROM 6 RX-772 19LG31 RFS 3600 LTV-32W1 DP-558 Heroes Enrxwi-G NV-A1 VR716 Minolta 7085 SP-6-spartan VI KD-LH1000R Messenger RM-BR300 DCR-DVD710 KX-DT346 Minolta 7255 SF-300-48 YZF-R1-1999 R-963S LA22A450c1V Professional 26PF4310 KX-TCD700 R2600 L196WTQ-BF Version P12107 KX-TCD410 RA-05 UE-40C6530 SWS-3049 JV-35 MD-R3 Dangerous CX3400 Hd CD IC-GM651 DA6152 Route 66 Konica 7022 Pvr DVD CVP-109-107-105-700 YSP-1 Bouilloire SHB6100 Nokia 3210 LE37A615 41 Accu SM 1102 MHC-RG490S GR8WHT 506 AFC MP720P X5DIJ Yamaha VL1 Samsung L310 KDC-135 WF-T1304TP Aqgmd 149 HM-332 Legendc Bizhub C35 YP-T10JQB Powerwave-4 Proxima KX-TG6473 Inverter S5 PRO 23LB230B4U 32PW9502 MP-705-4G 50PG60UR PS-42E92H DVD-VR350 37LG7000 AEU AVR-4800 CDP-CE305 CMF-2180 LE46C530f1W AZ5130 Convertible 2005 Series Supersport 1000 FX-83ES 2 0 R4250 USB7100 Kdlx30R-KD-lx10R SH-EX1200 DAV-DZ200 Collector DAB35 R 2005 ST600 DLS CA41 LE40B530p7W PF50 Pf60

 

manuel d'instructions, Guide de l'utilisateur | Manual de instrucciones, Instrucciones de uso | Bedienungsanleitung, Bedienungsanleitung | Manual de Instruções, guia do usuário | инструкция | návod na použitie, Užívateľská príručka, návod k použití | bruksanvisningen | instrukcja, podręcznik użytkownika | kullanım kılavuzu, Kullanım | kézikönyv, használati útmutató | manuale di istruzioni, istruzioni d'uso | handleiding, gebruikershandleiding

 

Sitemap

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101